23
Autoclave Fully automatic vertical steam sterilizers PURPOSE OF AUTOCLAVE Liquids such as nutrient media and buffer solutions Solid items such as pipette tips, tubes and filters Glassware and plastic articles Biohazard sterilization CONTROL AND DOCUMENTATION FEATURES In addition to a comprehensive LCD display: Password protection for operating machine. Independent temperature and pressure monitoring Cycle information recovery in the case of power failure or cycle interruption Fail Alert – Indicating cycle failure or interruption Door Alert – Indicating the door is unlocked RS 232 PC Connection Port for direct software updates and remote maintenance SAFETY FEATURES Door Safety Safety Valves Built-in Steam Generator Safety Safety alarms Drain Protection: Type Chamber Dimensions (ø x depth) (in mm) Chamber Volume (in Liters) External Dimensions (W x H x D) (in mm) 3850 ELV 380 x 490 62 650 x 745 x 500

Equipment Description

Embed Size (px)

Citation preview

Autoclave Fully automatic vertical steam sterilizers

PURPOSE OF AUTOCLAVE

Liquids such as nutrient media and buffer solutions Solid items such as pipette tips, tubes and filters Glassware and plastic articles Biohazard sterilization

CONTROL AND DOCUMENTATION FEATURES

In addition to a comprehensive LCD display: Password protection for operating machine. Independent temperature and pressure monitoring Cycle information recovery in the case of power failure or cycle interruption Fail Alert – Indicating cycle failure or interruption Door Alert – Indicating the door is unlocked RS 232 PC Connection Port for direct software updates and remote maintenance SAFETY FEATURES

Door Safety

Safety Valves

Built-in Steam Generator Safety

Safety alarms

Drain Protection:

Type Chamber Dimensions (ø x depth) (in mm)

Chamber Volume (in Liters)

External Dimensions (W x H x D) (in mm)

3850 ELV 380 x 490 62 650 x 745 x 500

LAB WATER BATH

Digital display

5L capacity; 120V 50/60Hz, 2.5A

Dimensions: 13L x 16W x 9D

Weight:16 lbs

Microprocessor PID Control

±0.24°C uniformity, ±0.5°C accuracy and stability at 37°C

Display shows both °C or °F Safety Features

Low profile and front-panel controls for easier access, safer operation

Dual thermostats guard against thermal runaway

Hinged acrylic or stainless-steel gable covers having fins that keep hands away from hot vapors

Covers that stay open at 90° or, with quick-release hinge, lift off completely for use with large glassware

Heating elements should not burn out if bath accidentally runs dry

Construction

Corrosion-resistant exterior with tough, easy-to-clean acrylic enamel coating

Temperature-resistant plastic rim insulates, that resist leaks, keeps its shape and won't dry out or crack like caulked seals

Exterior stays cool even after hours of operation Deep-drawn, stainless-steel reservoirs and perforated sample trays which prevent leaks, guard against rust and contamination

Rounded reservoir corners and sample trays with finger holes that allow for easy removal, make cleaning easier

Choice of acrylic or stainless-steel covers

With drain pump to empty reservoir

Specifications

Temperature Range, Maximum w/Lid Ambient to 100°C (212°F)

Temperature Accuracy at 37°C ±0.5°C

Temperature Uniformity at 37°C ±0.24°C

Temperature Stability at 37°C ±0.5°C

Temperature Control/Display PID/Digital ft.

Electrical Requirements 120V 50/60Hz

Resolution ±0.1°C

ft.Microprocessor PID Control

Lab Research Microscope

Digital Binocular; Brightfield Contrast

Optics: Traditional Plan Achromatic or Infinity-corrected 4x, 10x, 40x, and 100x oil, parfocal, and parcentered, standard objectives with coating to reduce reflection

Head: Video Binocular, 45° observation angle with interpupillary and dual diopter adjustments

Camera: 640 x 480 analog or 3 megapixel color camera

Video: RCA video output and 6.4 in., 360° rotating LCD viewing screen (12-563-530 only)

Eyepieces: 10x, 20mm widefield with built-in, collapsible eye cups

Illumination: 6V, 20W halogen illumination with easy, pull-out cartridge bulb replacement system

Mechanical Stage: Low-position, X/Y axis mechanical stage

Electrical: 110V to 240V auto-adjustable power supply

Carrying Handle: Built-in carrying handle that makes microscope easy to move

Focusing Stop: Factory set and user adjustable to protect slides

General purpose freezer

Capacity: 20 cu. ft.; 115V, 60Hz

Dimensions:

Interior: 20D x 27W x 57’’H

Exterior: 36L x 32W x 73’’H

Weight: 200 – 220 kg

Adjustable temperature from -20° to -12°C, with ±3°C stability

Equipped with manual defrost for sensitive biological sample storage

CFC-free R404A refrigerant

Durable, textured white enamel-coated steel exterior Foamed-in polyurethane insulation

One solid hinged door opens to a 90° angle, closes with a gentle push

Four adjustable legs ensure cabinets are level on irregular floors

Lab Refrigerator

Dimensions: Interior: 52D x 27W x 18’’H Exterior: 65L x 32W x 29’’H

Thermostat control of temperatures ranging from 1° to 8°C with ±3°C stability

Capacity, 17 cu. ft. (481L) Automatic defrost

CFC-free (R404A) refrigerant, polyurethane insulation

White enamel-coated steel cabinet, white epoxy powder-coated steel interior

Solid door that has hinge mechanism that holds door open at 95° angle, closes with a gentle push

Four adjustable legs that ensure cabinet is level on irregular floors

fixed white epoxy-coated steel-wire shelves which can resist most acids, solvents, and chemicals; provide 13.5 sq. ft. of shelving

BIOSAFETY UNIT

Description:

Designed for biological agents at Biosafety Levels 1–3

Class II, Type A2 Biological Safety Cabinet Packages

4’’ package, 120V 50/60Hz

AC motored cabinet

sloped front, bright workspace, and low noise level

with Digital Airflow Verification

features like UV light, electrical points, gas points

Real-time airflow adjustments ensure inflow and downflow velocities remain steady

Meet NSF/ANSI™ Standard 49

Pressure sensor filter monitoring that measures total airflow across the working area

Proprietary front window design which simplifies cleaning for a safer working environment

Indicator to adjust airflows as filter resistance changes

SmartFlow visually demonstrates cabinet's ability to compensate to maintain personal

protection

Analytical balance

Weighing Range: 120g Readability: 0.1mg Repeatability: 0.1mg Linearity: 0.2mg Including: Universal power adapter, USB data cable, in-use cover, application guide, dust cover Simple menu navigation and integrated applications at the touch of a key Clearly visible icons fully automatic internal calibration and balance adjustment connectivity to a printer or computer Level control: Glass level indicator with air bubble for centering Calibration: Internal, fully automatic calibration with configurable action level Weighing units: g, ct, mom, kg, lb, oz, ozt, tls, tlt, GN, dwt, mg, parts/lb, tlc, Kt, tol, bat, MS, N Stability indicator Tamper protection lock Housing protection: Acetone cleanable housing Language selection: English, French, Theft lock Output: Mini-USB Power: 120V 60 Hz Weight: 12 lbs Dimensions: 5 x 7 x 18”

Iso-temperature lab incubator

Large; Chamber capacity: 5.0 cu. ft.

Power: 120V

30° to 75°C (86° to 167°F) range

Incubators with gravity flow circulation

Efficient heating for routine laboratory procedures: drying and staining of slides, microbiological

determinations, and more.

Electrical receptacle inside (5A at 120V) to plug in a stirrer, shaker or other apparatus.

with two shelves

Microprocessor control located at the top of the incubator chamber

decrease set point temperature adjustments in 0.1°C increments

Over temperature value is automatically set at 3°C above setpoint

Circuit breaker protection; battery backup

Heat and Alarm indicators

Cabinet with durable, enamel-coated steel exterior

Extruded aluminum trim has acrylic powder coating

Large LED display

Silicone gasket on outer door to prevent heat loss

Outer door opens to 180° for unhindered access and features two grabber-type latches

Inner door is tempered glass

rubber feet to keep incubator from slipping and maintain a space between incubator and

benchtop for ventilation

Accessories:

25mL (60 each), 125 mL (9 each), 500 mL (8 each), 1L (4 each ) and 2 L ( 4 each) flask clamps.

Microwell plate clamp

General purpose bench top centrifuge

g force (rcf): 100–3,000 x g (100 x g increments) Speed: 100–4,400 rpm (in 100 rpm increments) Maximum capacity: 4 x 85 mL or 30 x 15 mL Number of rotors: 6 Acceleration time: <25 s Braking time: <25 s soft brake function Timer: 0–99 min, with continuous mode Power supply: 120 V/50–60 Hz Dimensions: (W x D x H) 12.5 x 15.6 x 9.5 in/32 x 40 x 24 cm Height: with lid open 20.7 in/52.5 cm Weight: 44 lb/20 kg 4 x 85 mL swing-bucket rotor with round buckets 4 adapters for 15 mL conical tubes and 4 adapters for 50 mL conical tubes

High purity water system

Reservoir: 30L reservoir made up of Polyethylene material with minimum release of extractables Compact, space-saving design Direct display of stored water level on RiOs and Elix systems Vent filter for removal of volatile organics, bacteria and CO2 Automatic UV exposure to reduce bacteria levels Eliminate the need for chemical sanitization Water leakage alarm Fits into Millipore PE Reservoir base Delivers pressurized water continuously Vent filters ((TANKMPK02)): Polyethylene vent filters to protect purified water from ingress of

airborne microorganisms Millipore Millipak Express 40 PK/1 filters: 0.22 µm membrane filters designed as a safe and

efficient barrier against particulates and bacteria.

ltrapure Water Quality

Parameter Value

Resistivity 18.2 MΩ.cm @ 25 °C

TOC ≤ 5 ppb (µg/L)

Pyrogens (endotoxins) < 0.001 Eu/mL (pyrogen-free) after BioPak

RNases < 0.01 ng/mL (RNase-free) after BioPak

DNases < 4 pg/mL (DNase-free) after BioPak

Microorganisms < 0.1 cfu/ml after Millipak or BioPak

Particulates > 0.22 µm < 1 particulate / mL after Millipak Express 40

Flow rate Adjustable from trigger: from 50 mL /min up to 2 L/min

* Resistivity can be displayed temperature-compensated at 25 °C or non-temperature-compensated as required by USP

Ultrapure Water delivery

Parameter Value

Manual dispense flow rate Adjustable between 50 and 2000 mL/min

Automatic dispense volume

100 mL, then 250 mL to 5 L by 250 mL increments, then 5 L to 60 L by 1 L increments

Volumetric dispense accuracy

3 % for volumes between 250 mL and 60 L

Volumetric dispense dispersion

CV < 3% for volumes between 250 mL and 60 L

Feed Water Specifications (*)

Parameter Value

Feed Water Quality Potable Tap Water Feed

Feed Water Conductivity < 2000 µS/cm @ 25°C

Feed Water TOC < 2000 ppb

Feed Water Pressure 1 - 6 bar

Feed Water Temperature 5 - 35°C

Feed Water Chlorine < 3 ppm

Feed Water Fouling Index < 12

Feed water pH 4 to 10 pH units

Feed Water Connection 1/2 in Gaz M

(*) If some feed water are out of specifications, solutions exist to make it acceptable for Milli-Q Direct operation – contact Millipore Tech Service for more information

Product Dimensions

Accessories:

Vent Filters for Pure Water Storage Reservoirs (TANKMPK01) Progard T3 Pack for RO cartridge Wall mounting bracket Wall mounting bracket – Tank Water sensor for integral Sanitary tablets Millipore Q-pak TEX

Pure Water Quality

Parameter Value

Ions rejection 97 to 98% with new RO cartridge

Organics Rejection > 99 % for MW > 200 Dalton

Particulates & Bacteria Rejection

> 99%

Pure Water production and delivery

Parameter Value

Production Flow Rate 8 L/hour or 16 L/hour

Delivery Flow rate From tap: up to 2.5 L/min From optional pump: up to 15 L/min at 1 bar

Q-POD Accessory Dimensions

Parameter Value

Q-POD height 579 mm (23.50 in)

Q-POD diameter 230 mm (9.05 in)

Dispenser delivery loop length 800 mm (31.49 in)

Q-POD weight (packaged) 7.2 kg (15.87 lb)

Q-POD weight (empty) 5 kg (11.02 lb)

Q-POD weight (with water) 5.5 kg (12.12 lb)

Loop & cable to system length 290 cm (114.1 in)

Data connection Parallel Port (25-pinD-Sub) for print-out

Incubator shaker

Combined incubated/refrigerated temperatures with orbital shaking in a compact footprint. Designed to minimize bench space and are affordably priced. Ideal for cell culture, solubility studies, extraction procedures, protein expression and many

other applications. Transparent lid Chamber holding atleast four 1L flasks Choose from two temperature ranges: incubated (5°C above ambient to 80°C) Monitor and control chamber temperature range with ±0.1°C accuracy at 37°C Triple eccentric drive handles heavy loads, uniform agitation and continuous 24-hour operation,

even at high speeds Over temperature safety feature with independent thermostat provides additional backup by

controlling heat if main temperature controller fails Interlock stops platform when lid is opened LED displays for speed, time and temperature Variable speed control from 15 to 500rpm Continuous and timed operation from 0.1 hour up to 999 hours or 0.1 to 999 min. Shaker shutdown and audible/visual alarms signal temperature deviations or if unit operates

±10% of set speed, preventing shaker from walking Soft-start feature for sudden starts and stops, splashing of vessel contents or wetting of flask

closure Set point retention retains parameters during power failure and restarts unit automatically after

power is restored Solid-state DC brushless motor is maintenance-free Operating Chiller Provides a refrigerated atmosphere For plasmid purification and protein expression in bacteria for use with MaxQ 4450 with cooling

coil option Achieve temperature ranges from 20° to 30°C

Specifications

Temperature Accuracy ±0.1°C at 37°C

Motor Triple eccentric drive

Chamber Capacity 4 x 1L flasks

Orbit 0.75 in. (1.9cm)

Platform L x W 11 x 13 in. (28 x 33cm)

Platform Load Capacity 35 lb. (15.9kg)

Overall L x W x H 27.2 x 14.1 x 15.8 in. (69.1 x 35.8 x 40.1cm)

Shipping Weight 77 lb. (35kg)

Eppendorf type pipette systems

2.5, 10, 20, 100, 200, 1000 microlitre pipettes Pipette stand One full rack of Pipette tips for each volume of pipettes

pH meter pH/mV/C/F modes Includes meter pH/ATC plastic body refillable electrode liquid-filled, glass body combination pH Ag/AgCl Electrode ATC probe (13-620-19). Operational manual Power supply pH standards LCD display

HPLC

Item LC-2010CHT LC-2010AHT

Quaternary pump

Flow rate setting range 0.001 ~ 5 mL/min (1.0-35.0 MPa/145-5076psi)

Flow rate accuracy ± 1% (1mL/min, 3.0-10.0 MPa/435-1450psi, using water, and fixed ambient temperature of 20°C , except during gradient solvent delivery), ± 2% (except for above conditions) or ± 2μL/min, whichever is greater

LPGE Number of solvents and setting range

Up to 4 solvents 0 to 100%, 0.1% steps

Concentration accuracy

± 0.5% (aqueous acetone/water, binary gradient, flow rate 0.1-2.0mL/min, pressure 1.0-20.0MPa/145-2900psi)

Concentration precision

± 0.1% (aqueous acetone/water, binary gradient, flow rate 0.1-2.0mL/min, pressure 1.0-20.0MPa/145-2900psi)

Sampler Injection method Variable volume (without sample loss)

Injection volume setting range

0.1-100μL (standard), 1- 2000μL in 1μL steps)

Sample capacity

1 ml vials 350

1.5 ml vials 140

4 ml vials 100

MTP 4 96- or 384-well micro titer plates

DWP 4 96-well deep-well plates

Injection repeatability RSD<0.3% (with 10μL injection)

Carry over 0.01% (under naphthalene analysis conditions)

Injection volume accuracy ± 1 % (50μL, n=6)

Injection volume correction

Possible

Sample cooler (LC-2010CHT)

4 to 40°C using Peltier element

Oven Type Block heating/cooling with preheating of the mobile phase

Temperature control precision

± 0.1°C

Temperature control range

(Ambient temperature -15°C) to 60°C

Both UV Detector And RI detector

Light source Deuterium lamp

Wavelength range 190 to 600nm

Bandwidth 8nm

Wavelength accuracy ± 1nm

Wavelength precision ± 0.1nm

Drift 1 x 10-4 AU/h (250nm air cell)

Noise level ± 0.25 x 10-5 AU (for response of 1s, 250nm, air cell)

Cell path length, cell volume

10mm, 8μL (STD flow cell), 5mm, 2.4μL (semimicro flow cell)

2 wavelengths monitoring Any two wavelengths from 190 to 370nm or 371 to 600nm

Controller Display Backlit liquid crystal display (320 x 240 dots), black and white

Input/output terminals 2 x external inputs, 2 x external outputs, 1 x optical link (for chromatopac), 1 x

Operating temperature range 4 to 35°C

Power requirements AC 100V - 240V

Dimensions,Weight Compact and light weight enough to handle by two persons

Computer One dedicated PC to operate (25’’ inches monitor)

Column C18 reverse phase and aminex carbohydrate column

Installing and training needed

Gas chromatography

Gas chromatography start up package, 230 V 60 Hz

Detectors: FID and TCD

Columns: columns for alcohol, organic acid, phenolic analysis etc

Injection unit : Split/Splitless Injector module

Flame Ionization Detector module

Thermal Conductivity Detector module

Approximate Instrument Dimensions and Weight Height: 18-3/8 in. (465 mm) Width: 25-7/8 in. (655 mm) Depth: 20-1/8 in. (511 mm) Weight: 90 pounds (41 kg)

Operating range: 0–55 °C ambient (20–27 °C optimum) 5–95% humidity (50–60% optimum)

Detector Signal For external processing - recorder, integrator, or computer

Power Requirements Voltages: 120/200/220/240 Range: +10%, –10% each Frequency: 47.5–66 Hz Output: 7,500 Btu/hr max

Installing and training : Needed

UV visible spectrophotometer

UV visible spectrophotometer

with and without nano cell

external dimensions: 24’L x 19” W x 11” H

weight: 32 lbs

Electrical requirements: 10 – 240 V, 50 – 60 Hz, selected automatically 150 W maximum

Specifications

Bandwidth Variable: 1nm; 2nm; AFBG Microcell optimized; AFBG Fiber optic optimized; AFBG Materials optimized

Optical Design

Double Beam with sample and reference cuvet positions; Application Focused Beam Geometry; Czerny-Turner Monochromator

Light Source

Xenon flash lamp, 3-year warranty (Typical lifetime: 5 years)

Detector Dual Silicon Photodiodes

Wavelength

Range 190 to 1100nm

Accuracy ±0.8nm (full range 190 to 1100nm)

Scanning Speed

<1 to 6000nm/min; variable

Photometric

Range >3.5A

Accuracy 0.5A: ±0.004A 1A: ±0.006A 2A: ±0.010A Measured at 440nm using neutral density filters traceable to NIST™/NPL

UV Accuracy

0.5A: ±0.004A; 1A: ±0.006A; 2A: ±0.010A (Measured at 440nm using neutral density filters traceabel to NIST™/NPL

Noise 0A: ≤0.00015 A 1A: ≤0.00050 A 2A: ≤0.00080 A RMS 260nm, 1nm SBW, RMS

Bioreactor system

Suitable for microbial Culture Working Volumes from 0.4 to 1L Integrated 4-gas mixing system (Air, O2, N2, CO2) Freely selectable gas composition to sparger or overlay (headspace) 4 Flow Meters for individual flow rate setting DO control via automatic valves for Air and O2 pH control via CO2 / Acid and Base Special Impeller Design for low shear stress Suitable for Bacteria, Yeast and Fungi cultivation Working Volumes from 0.4 to 5L Airflow gassing system with oxygen enrichment capability Efficient agitation system for high cell density cultures Automatic DO control for agitation, air and O2 flow or substrate addition Anaerobic culture PC to control and process/ data acquisition Installing and training onsite needed.

Ultrasonic system and accessories .

Applications: Biological cell disruption/homogenization, emulsification, reaction acceleration, dispersion, fine mixing, degassing

Processing of 700mL and less Soft-touch keypad Autotune plus Memory (AT/M) provides fully-automatic tuning and stores frequency at the end

of each cycle Multiple modes of operation continuous, pulsed, timed, and temperature end-point Setup menu in five languages: English, Spanish, Italian, German or French Digital parameter setting with valid paramter range checking Digital timer (9 hours, 59 minutes, 59 seconds) Amplitude is adjustable from 10 to 100% User I/O offers remote start/stop control and teh ability to view temperature, amplitude, and

power values during experiments Automatic end-of-cycle shutoff using limit paramters Self diagnostics on start-up RS-232 port for remote computer access Sound proog enclosure

PCR

Mastercycler® nexus

Thermoblock Aluminum

Sample capacity 96x 0.2 mL PCR tubes or 77x 0.5 mL PCR tubes or 1x

96 well PCR plate

Temperature control range 4-99°C

Temperature control mode Fast, Standard, Safe

Heating technology of the block

Peltier Elements, Triple Circuit Technology

Gradient No

Lid temperature range 37-110°C

Lid Type Flex lid for ergonomic lid opening

Block homogeneity 20-72°C < ±0.3°C, 95°C < ±0.4°C

Block temperature accuracy

≤ ±0.2°C

Heating rate approx. 3°C/s

Cooling rate approx. 2°C/s

Interfaces USB, Ethernet, CAN in/out

Power consumption 700 W

Dimensions (W x D x H) 25 x 41.2 x 32.1 cm

Weight 24 lb / 10.9 kg

Accessories:

Submarine electrophoresis unit

Gel Dimensions (w x l) . . . . . . . . . . . . . . . 15 x 20 cm, 15 x 15 cm, or 15 x 10 cm Maximum Buffer Volume . . . . . . . . . . . . . . 1.2 L Maximum Power Settings . . . . . . . . . . . . . . 200 V, 100 mA, 20 W Maximum Sample Capacity . . . . . . . . . . . . 60 Maximum Temperature . . . . . . . . . . . . . . . 45°C Indoor Use . . . . . . . . . . . . . . . . . . . . . . . . . 4-40°C Humidity . . . . . . . . . . . . . . . . . . . . . . . . . . Up to 80% Unit Dimensions (l x h x w) . . . . . . . . . . . . 36 x 14 x 18.2 cm Safety Certifications . . . . . . . . . . . . . . . . . . EN61010-1, UL61010A-1, CSA C22.2 1010.1, CE

Electrophoresis power supply 400 MA 300V 120V

o Versatile, compact FB300 runs up to three gels at once at either constant current or constant voltage

o Stackable, solid, compact power source o Integral timer and auto shutoff prevents fear of losing valuable information

o No-slip feet anchor provides safe operation o Ideal for mini SDS-PAGE, DGGE/CDGE and DNA/RNA submarine electrophoresis

o Maximum voltage: 300V o Maximum current: 400mA o Maximum power: 75w o Three jacks o Internal timer: 0 to 999 minutes

BioDOc imagaing workstation: o Uses your existing computer running capture software on supplied CD o High resolution images with low-light capability

CCD Camera and Capture Software

o Software enables acquisition, camera control, enhancement, annotation and archiving of digital

image; compatible with Windows™ 98SE, ME, XP, 2000 o DigiCam 110 digital color camera, 5.1 megapixel resolution, 4:1 zoom lens; max. Field of View, 29.5

x 22.2cm o Apertures from f/2.8 to f/8.0; automatic or manual focus and exposure; 1/4000 to 16 seconds

exposure times o Focusing ranges: normal, 8 to 31 in. (0.2m to 0.8m); close-up, 1 to 8 in. (0.03m to 0.2m) o UVP filter and diopter included o Resolution settings from 640 x 480 to 2592 x 1944; interpolated print resolution to 3264 x 2448 o High or low image compression with multiple file formats: jpeg, bmp, tif, gif, tga, png o USB interface; operates on Li-Ion battery; with charger and AC power supply o Additional functions available when software is not in use: multi-mode exposure controls, color LCD

monitor, variable shutter speeds, flash controls, Smart Memory Card, utility and photo software and more

o Camera measures 43/8 x 3 x 23/4 in. (109.2 x 76.2 x 68.6mm); weight, 11 oz. (307g)

Darkroom

o Sturdy enclosure provides a darkroom environment and protects the camera o Full-access door; built-in overhead white light o Safety interlock turns UV off when door is open o Viewer window for inspecting gels without opening the door

Analysis software Quickly and automatically detect lanes and bands Designed for use with UVP's basic imaging systems: DigiDoc-It™, MultiDoc-It™ and ChromaDoc-It™;

can also be loaded on a separate computer to analyze gels from BioDoc-It™ systems Image analysis detects straight, curved or slanted lanes and bands automatically or manually and

creates histograms for detailed visual analysis Generates easy-to-interpret quantitative data of lanes and bands Colony Counting function uses wizard commands to set the automatic colony counting of user-defined

areas Enhance images with brightness, contract, gamma, emboss, invert and pseudo color Annotate with text, lines, arrows, ellipse, and highlighter tools—show, hide or burn into image

Save images as various file formats including TIFF, JPEG, BMP and GIF for use in presentations or documentation

Create detailed and user-configured reports Compatible with Windows™ XP (SP2) and newer

UV light converter plate: uv light to white light converter

Plate is specially designed to easily fit on the transilluminator filter surface

UV to white light plates convert to white light for viewing protein gels, coomassie blue stained or silver

stained media

Uniquely phosphored glass assembly (patent pending) converts the UV radiation via a white diffuser

Converts UV to 460-470nm with the Visi-BlueT plate for viewing GFP stains, or to 365nm UV with the

UV/UV plate for preparation and gel excision

Scratch-resistant glass is mounted in a metal housing for durability

Rubber seal stops the plate from sliding

Handles are situated on two sides of the plate for easy handling

Several standard plate sizes are available, custom sizes are also available

UVP mitsubhishi printer thermal digital Document gel images with high-quality, gray-scale thermal prints

Connect printer to UVP's systems easily Compact printer processes low cost prints in seconds

UVP filter emission sybr Green