Equipment for Engineering Education & Research SOLTEQ ® FLOW CHANNEL AND FLUME APPARATUS MODEL: FM 27 T HIS Flow Channel and Flume Apparatus (Model: FM 27) has been designed for students to study the principles of fluid mechanics pertaining to engineering structures in open channel flow. The unit comes with an open channel made of transparent working section mounted on a strong framework. The unit is supplied with a 2.5 m long flume which can be tilted using a calibrated screwjack. The unit can also be supplied with an optional 5.0 m and 10.0 m long flume. EXPERIMENTAL CAPABILITIES Measurements of water level by hook and point gauges Measurement of flow rate using a Pitot-static tube Force-momentum and steady flow energy equations. Relationship between water level above the crest of a weir and flow rate over the weir The unit is fitted with pressure tappings and fixing points as well as longitudinal scale. The scale is positioned at the top of the channel so that the depth gauges and pitot-static tubes can be positioned along the channel length. The unit is supplied with a hydraulics bench for the water supply incorporating a smooth and uniform flow mechanism. The water flow rates can be measured either by using the volumetric tank or by flow meter.

Equipment for Engineering Education & Research FLOW ...solution.com.my/pdf/FM27(A4).pdfSOLTEQ Equipment for Engineering Education & Research FLOW CHANNEL AND FLUME APPARATUS MODEL:

  • Upload
    others

  • View
    41

  • Download
    0

Embed Size (px)

Citation preview

Equipment for Engineering Education & ResearchSOLTEQ®

FLOW CHANNEL AND FLUME APPARATUS

MODEL: FM 27

THIS Flow Channel and Flume Apparatus (Model: FM 27) has been designed for students to study the

principles of fluid mechanics pertaining to engineering structures in open channel flow. The unit comes

with an open channel made of transparent working section mounted on a strong framework. The unit issupplied with a 2.5 m long flume which can be tilted using a calibrated screwjack. The unit can also be supplied

with an optional 5.0 m and 10.0 m long flume.

EXPERIMENTAL CAPABILITIES

w Measurements of water level by hook and point

gauges

w Measurement of flow rate using a Pitot-static tube

w Force-momentum and steady flow energy

equations.

w Relationship between water level above the crest

of a weir and flow rate over the weir

The unit is fitted with pressure tappings and fixing

points as well as longitudinal scale. The scale is

positioned at the top of the channel so that the depth

gauges and pitot-static tubes can be positioned along

the channel length. The unit is supplied with a

hydraulics bench for the water supply incorporating a

smooth and uniform flow mechanism. The water flow

rates can be measured either by using the volumetric

tank or by flow meter.

SOLTEQ

Equipment for Engineering Education & ResearchSOLTEQ®

w Flow and level control using hydraulic structures

w Sub-and super-critical flow and the underlying

characteristics of waves.

w Measurements of velocity profiles.

SPECIFICATIONS

Flow Channel:

Material: clear acrylic

Size: 2,500 mm (L), 250 mm (H), 75 mm (W)

- Model: FM27A

Size: 5,000 mm (L), 250 mm (H), 75 mm (W)

- Model: FM27B

Size:10,000 mm (L), 250 mm (H), 75 mm (W)

- Model : FM27C

(Please specify model when ordering)

Hydraulics Bench:

Made from glass reinforced plastic (GRP)

Sump tank capacity: 250 litres

Volumetric tank capacity: 40 litres

Circulation pump

Flow meter: range 0.5 to 2.0 L/sec.

Vernier Level Gauges:

1 x 150mm resolution 0.1m

2 x 300mm resolution 0.1m

Basic model is supplied with the followings:-

a) Venturi flume

b) Sharp and broad crested weirs

c) 3 vernier level gauges

Sharp Crested Weir

d) Crump weir

e) Adjustable undershot weir

OPTIONAL ITEMS

a) Pitot tube and manometer board

b) Culvert fitting, one edge square, one rounded

c) Flow splitters, central wall with various nose pieces

d) Free overflow spill nay section complete with ski

jump, sloping apron and bleaded reverse curvature

attachments

e) Syphon spill way and air regulated syphon

f) Model radial gate

g) Wave generator and wave absorbing beach

h) Artificially toughened bed 2.5 m (2 and 4 pieces

required for 5.0 m and 10.0 m channel respectively)

i) False floor sections for gradually varied profiles

REQUIREMENT

Electricity: 240VAC/1-phase.50Hz.

Water: Laboratory mains supply

OVERALL DIMENSION

Length: 3.50 m

Width: 1.00 m

Height: 1.50 m

MANUAL

Operating and Experiment Manual for students in

English.

Broad Crested Weir

SOLTEQ

Equipment for Engineering Education & ResearchSOLTEQ®

Crump Weir

Adjustable Undershot Weir

Venturi Flume

Hydraulic Jump

Radial Gate

060422-SESB

Equipment for Engineering Education & ResearchSOLTEQ®

Our range of teaching equipment can be complemented with our

SOLDAS and SOLCAL software.

SOFTWARE & e - LEARNING

SOLDAS® - Supervisory Control & Data Acquisition

- Data Logging

- Signal Analysis

- Process Control

- Real-Time Display

- Tabulated Results

- Graph of Experimental Results

SOLCAL® - Computer Aided Learning

- Multimedia Features

- Interactive

- Graphic Simulation

- Experiment Result Samples

- Full Experiment Manuals

Contact us for a catalog CD

SOLUTION ENGINEERING SDN. BHD.(Co. No. 174876-M)

Sales Office :

No.3, Jalan TPK 2/4, Taman Perindustrian Kinrara,47100 Puchong, Selangor Darul Ehsan, Malaysia.Tel. No. : +(603) 80758000Fax. No. : +(603) 80755784

R&D Office :

G-2A, Incubator 3, Technology Park Malaysia,Bukit Jalil, 57000 Kuala Lumpur, Malaysia.Tel. No. : +(603) 8996 0023

Email : [email protected] site : http//www.solution.com.my/

AGENT:

BUATAN MALAYSIA