www.recom-power.com REV.: 1/2018 ECO-1
Features
Unregulated Converters
• High efficiency uo to 84% full load
• Low deviation (10% - 100% load)
• 1kVDC and 2kVDC isolation option
• UL60950-1 and EN/IEC60950-1 certified
• -40°C to +100°C operating temperature range
• 1W SIP7 package RB/E
DescriptionThe RB/E series is an unregulated DC/DC converter in standard SIP7 package style. This series has been designed to offer exceptionally high efficiency at low loads, an extended operating temperature range and low deviation (10% to 100%). Uses include applications with restricted energy budget and industrial applications where a high efficiency level is required.
DC/DC Converter
1 Watt SIP7Single Output
E358085
UL60950-1 certifiedCAN/CSA-C22.2 No 60950-1 certifiedEN60950-1 certifiedIEC60950-1 certified
Selection GuidePart nom. Input Output Output Efficiency max. CapacitiveNumber Voltage Voltage Current typ. (1) Load (2)
[VDC] [VDC] [mA] [%] [µF]
RB-3.305S/E (3,4) 3.3 5 200 83 2200
RB-0505S/E (3,4) 5 5 200 84 2200
RB-1205S/E (3,4) 12 5 200 84 2200
RB-2405S/E (3,4) 24 5 200 81 2200
Model Numbering
Notes: Note3: standard part is without continuous short circuit protection add suffix „/P“ for continuous short circuit protection Note4: add suffix „/H“ for 2kVDC isolation or add suffix „/HP“ for 2kVDC isolation and continuous short circuit protection
Ordering Examples:RB-1205S/E: 12VDC Input Voltage, 5VDC Output Voltage, Single OutputRB-3.305S/EP: 3.3VDC Input Voltage, 5VDC Output Voltage, Single Output with continuous short circuit protectionRB-0505S/EH: 5VDC Input Voltage, 5VDC Output Voltage, Single Output with 2kVDC isolationRB-0505S/EHP: 5VDC Input Voltage, 5VDC Output Voltage, Single Output with 2kVDC isolation and continuous short circuit protection
nom. Input Voltage
Output Voltage
RB- __ 05S/E Protection (3)
Isolation Option (4)
Single
Notes: Note1: Efficiency is tested at nominal input and full load at +25°C ambient Note2: Max Cap Load is tested at nominal input and full resistive load and is defined as the capacitive load that will allow start up in under 1s without damage to the converter
www.recom-power.com REV.: 1/2018 ECO-2
DC/DC ConverterSpecifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up otherwise stated)
RB/ESeries
BASIC CHARACTERISTICSParameter Condition Min. Typ. Max.Internal Input Filter type
Input Voltage Range ±10%
Start-uo time 250ms
Minimum Load (5) 0%
Internal Operating Frequency 20kHz 90kHz
Output Ripple and Noise 20MHz BW 50mVp-p 100mVp-p
Notes: Note5: Operation below 10% load will not harm the converter, but specifications may not be met
Efficiency vs. Load
RB-xx05S/E
0 10 20 30 40 50 60 70 80 90 100
100
80
60
40
90
70
50
30
20
10
0
Effic
ienc
y [%
]
Output Load [%]
3.305050512052405
REGULATIONSParameter Condition ValueOutput Accuracy ±5.0% max.
Line Regulation low line to high line ±1.2% max.
Load Regulation 10% to 100% load 12.0% typ.
continued on next page
Tolerance Envelope
+10%
+5%
Vnom
+5%
-2%
-5%
Outp
ut V
olta
ge [%
]
10 50 100
Output Load [%]
Typical Load Line
www.recom-power.com REV.: 1/2018 ECO-3
DC/DC ConverterSpecifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up otherwise stated)
RB/ESeries
Deviation vs. Load
25
15
5
-50
20
10
0
-10
Devi
atio
n [%
]
0 10 20 30 40 50 60 70 80 90 100
Output Load [%]
3.305050512052405
RB-xx05S/E
PROTECTIONSParameter Type Value
Short Circuit Protection (SCP)without suffix
With suffix “/P”1 second
continuous
Isolation Voltage (6) I/P to O/P
without suffixtested for 1 secondrated for 1 minute
1kVDC500VAC
with suffix “/H”
tested for 1 secondrated for 1 minute
2kVDC1kVDC
Isolation Resistance 10GΩ min.
Isolation Capacitance 75pF max.
Insulation Grade basic
Notes: Note6: For repeat Hi-Pot testing, reduce the time and/or the test voltage Note7: Refer to local wiring regulations if input over-current protection is also required. Recommended fuse: T1A slow blow type
ENVIRONMENTALParameter Condition Value Operating Temperature Range full load @ free air convection (see graph) -40°C to + 100°C
Operating Altitude 2000m
Operating Humidity non-condensing 95% RH max.
Pollution Degree PD2
MTBF according to MIL-HDBK-217F, G.B.+25°C
+100°C3459 x 103 hours756 x 103 hours
continued on next page
www.recom-power.com REV.: 1/2018 ECO-4
DC/DC ConverterSpecifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up otherwise stated)
RB/ESeries
-40 -20 0 20 40 7060-30 -10 10 30 50 80 90 110100
100
80
60
40
90
70
50
30
20
10
0
Outp
ut L
oad
[%]
Ambient Temperature [°C]
Derating Graph(@ free air convection)
SAFETY AND CERTIFICATIONSCertificate Type (Safety) Report / File Number Standard
Information Technology Equipment, General Requirements for Safety 1602031IEC60950-1:2005, 2nd Edition + A2:2013
EN60950-1:2006 + A2:2013
Information Technology Equipment, General Requirements for Safety E358085-A4-ULUL60950-1, 2nd Edition:2007
CAN/CSA C22.2 No. 60950-1-03, 2nd Edition:2007
EAC RU-AT.49.09571 TP TC 004/2011
RoHs 2+ RoHS-2011/65/EU + AM-2015/863
DIMENSION AND PHYSICAL CHARACTERISTICSParameter Type Value
Materialcase
pottingPCB
non-conductive black plastic (UL94 V-0) epoxy, (UL94 V-0)
FR4, (UL94 V-0)
Dimension (LxWxH) 19.6 x 6.0 x 10.2mm
Weight 2.2g typ.
continued on next page
www.recom-power.com REV.: 1/2018 ECO-5
DC/DC ConverterSpecifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up otherwise stated)
RB/ESeries
Pinning informationPin # Single
1 +Vin2 -Vin4 NC5 -Vout6 +Vout
Tolerance:xx.x= ±0.5mmxx.xx= ±0.25mm
1 2 64 5 1 2 64 5
0.50
1.27
10.2
0.51+0.10/-0.05
6.0
1.00 Ø +0.15/-0
19.6
5x2.54= 12.702.00 2.54
2.54
4.10 0.25±0.05
Marking
Bottom View
Top View
embossed logo
Dimension Drawing (mm)
Recommended Footprint Details
NC = no internal connection
PACKAGING INFORMATIONParameter Type ValuePackaging Dimension (LxWxH) tube 520.0 x 16.0 x 9.0mm
Packaging Quantity tube 25pcs
Storage Temperature Range -55°C to +125°C
Storage Humidity 95% RH max.
The product information and specifications may be subject to changes even without prior written notice.The product has been designed for various applications; its suitability lies in the responsibility of each customer. The products are not authorized for use in safety-critical applications without RECOM’s explicit written consent. A safety-critical application is an application where a failure may reasonably be expected to endanger or cause loss of life, inflict bodily harm or damage property. The applicant shall indemnify and hold harmless RECOM, its affiliated companies and its representatives against any damage claims in connection with the unauthorized
use of RECOM products in such safety-critical applications.