113
ESCUELA POLITÉCNICA NACIONAL FACULTAD DE INGENIERÍA ELÉCTRICA Y ELECTRÓNICA REINGENIERÍA DE UNA RED DE DATOS CORPORATIVA PARA LA UNIVERSIDAD DE LAS AMÉRICAS, SEDE QUITO: ANÁLISIS, LINEAMIENTOS Y APLICACIÓN. TOMO II PROYECTO PREVIO A LA OBTENCIÓN DEL TÍTULO DE INGENIERA EN ELECTRÓNICA Y REDES DE INFORMACIÓN MARÍA SORAYA CARRASCO RUANO ESTHER MARÍA PARRA MORA DIRECTOR: ING. XAVIER ARMENDARIZ, MBA. Quito, julio 2007

ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ESCUELA POLITÉCNICA NACIONAL

FACULTAD DE INGENIERÍA ELÉCTRICA Y

ELECTRÓNICA

REINGENIERÍA DE UNA RED DE DATOS CORPORATIVA

PARA LA UNIVERSIDAD DE LAS AMÉRICAS, SEDE QUITO:

ANÁLISIS, LINEAMIENTOS Y APLICACIÓN.

TOMO II

PROYECTO PREVIO A LA OBTENCIÓN DEL TÍTULO DE INGENIERA EN

ELECTRÓNICA Y REDES DE INFORMACIÓN

MARÍA SORAYA CARRASCO RUANO

ESTHER MARÍA PARRA MORA

DIRECTOR: ING. XAVIER ARMENDARIZ, MBA.

Quito, julio 2007

Page 2: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ÍNDICE

CONTENIDO

ÍNDICE GENERAL

TOMO I

ÍNDICE GENERAL IÍNDICE DE FIGURAS VIIIRESUMEN XIIIPRESENTACIÓN XVCAPÍTULO 1 FUNDAMENTOS TEÓRICOS I

1.1 PROTOCOLOS, NORMAS EIA/TIA Y PLATAFORMAS 11.1.1 ARQUITECTURA POR CAP AS: PILA DE PROTOCOLOS 11.1.1.1 Modelo de referencia OSI 22.1.1.2 Modelo de referencia TCP/IP 3

1.1.1.2.1 Capahostared 41.1.1.2.2 Capa Internet 41.1.1.2.3 Capa transporte 41.1.1.2.4 Capa aplicación 4

1.1.2 EQUIPOS ACTIVOS UTILIZADOS EN REDES 51.1.2.1 Hub 51.1.2.2 Gateway 61.1.2.3 Switch 61.1.2.4 Router 81.1.3 CONFIGURACIONES DE EQUIPOS Y SERVICIOS DE RED 91.1.3.1 Configuraciones de equipos de telecomunicaciones 91.1.3.2 Configuraciones de servicios de servidores 91.1.4 CABLEADO ESTRUCTURADO 101.1.4.1 Aplicaciones 101.1.4.2 Elementos 11

1.1.4.2.1 Cableado horizontal 111.1.4.2.2 Cableado vertical, vertebral o de backbone 111.1.4.2.3 Cuarto de equipo 111.1.4.2.4 Cuarto de telecomunicaciones 12J . 1.4.2.5 Sistema de puesta a tierra y puenteado 121.1,4.2.6 Área de trabajo 12

1.1.4.3 Estándares 131.1.4.3.1 Estándar ANSI/T1A/EIA 568 B de Cableado de Telecomunicacionesen Edificios Comerciales 131.1.4.3.2 Estándar ANSI/TIA/EIA 569 A de Rutas y Espacios deTelecomunicaciones en Edificios Comerciales 171.1.4.3.3 Estándar ANSI/TIA/EIA 606 A de Administración de Infraestructurade Telecomunicaciones en Edificios Comerciales 171.1.4.3.4 Estándar ANSI/TIA/EIA 607 de Requerimientos de Puesta a Tierra yPuenteado de Telecomunicaciones de Edificios Comerciales 18

1.2 TECNOLOGÍAS DE REDES DE ÁREA LOCAL 191.2.1 IEEE 802.3 (Ethernet) 191.2.1.1 Especificaciones de la capa física 19

Page 3: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ÍNDICE II

1.2.1.2 Control de acceso al medio 191.2.2 LAN INALÁMBRICAS (Wireless LAN) 211.2.2.1 Especificaciones de la capa física 22í.2.2.2 Control de acceso al medio 231.2.2.3 Estándares IEEE 802.11 26

1.3 TECNOLOGÍAS DE REDES DE ÁREA EXTENSA (WAN) 271.3.1 FRAME RELAY 271.3.1.1 Funcionamiento 271.3.1.2 Control de flujo y de errores 30

1.4 PROTOCOLO TCP/IP 301.4.1 DIRECCIONES ÍP 311.4.1.1 Direcciones IP especiales 331.4.1.2 Máscara de subred 331.4.1.3 Definición de subredes 341.4.2 PROTOCOLO IP 351.4.3 PROTOCOLO TCP 36

1.5 ADMINISTRACIÓN Y GESTIÓN DE REDES 371.5.1 COMPONENTES 371.5.2 ÁREAS 381.5.3 PROTOCOLO DE ADMINISTRACIÓN ESTÁNDAR EN INTERNET.. 391.5.3.1 Mensajes SNMP 401.5.3.2 Tipos de datos de SNMP 41

1.6 SEGURIDAD DE REDES 421.6.1 AMENAZAS Y TIPOS DE ATAQUES 431.6.1.1 Amenazas 431.6.1.2 Ataques 441.6.2 POLÍTICAS DE SEGURIDAD 441.6.3 CERTIFICADOS DIGITALES 441.6.4 FIREWALLS 451.6.5 REDES PRIVADAS VIRTUALES (VPN) 461.6.6 REDES LAN VIRTUALES (VLANs) 471.6.6.1 Tipos de VLAN 48

1.7 TELEFONÍA IP Y VOIP 491.7.1 VOZ SOBRE IP (VOIP) 491.7.1.1 Protocolos de administración de la ruta de audio VoIP: RTP/RCTP 501.7.1.2 Señalización VoIP: H.323 51

1.7.1.2.1 Pila de protocolos 511.7.1.2.2 Elementos 52

1.7.1.3 Señalización VoIP: SIP 541.7.1.3.1 Fundamentos de SIP 541.7.1.3.2 Arquitectura SIP 54

1.7.1.4 Comparación entre H.323 y SIP 551.7.2 TELEFONÍA IP 561.7.2.1 Funcionamiento 561.7.2.2 Diferencias de la telefonía IP con la telefonía convencional 57

CAPÍTULO 2.ANÁLISIS DE LA INFRAESTRUCTURA ACTUAL DE LA RED 58INTRODUCCIÓN 58ESTRUCTURA JERÁRQUICA DEL DEPARTAMENTO DE TECNOLOGÍAS 592.1 ANÁLISIS DE LA INFRAESTRUCTURA 60

Page 4: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ÍNDICE

2.1.1 INSTALACIONES 602.1.2 EQUIPAMIENTO 612.1.2.1 Equipos 612.1.2.2 Servidores 652.1.2.3 Estaciones de trabajo 742.1.2.4 Direccionamiento IP 75

2.2 ANÁLISIS DE LA TOPOLOGÍA DE LA RED DE DATOS 772.2.1 INTERCONEXIÓN DE CAMPUS 772.2.2 DISTRIBUCIÓN DE LAS REDES LAN EN CADA UNO DE LOSCAMPUS 792.2.2.1 Campus Principal 80

2.2.2.1.1 VLAN estudiantil 802.2.2.1.2 VLAN administrativa 802.2.2.1.3 Red inalámbrica 812.2.2.1.4 Descripción general de la LAN en el campus Principal 81

2.2.2.2 Caamafio 1 822.2.2.3 Caamaño2 822.2.2.4 Campus 6 de Diciembre 842.2.2.5 Expo Centuri 852.2.2.6 Descripción general de la LAN de los campus Caamaño 1, Caamaño 2,Expo Centuri y 6 de Diciembre 85

2.3 ANÁLISIS DEL SISTEMA DE CABLEADO ESTRUCTURADO 862.3.1 CABLEADO VERTICAl 872.3.2 CABLEADO HORIZONTAL 882.3.3 RACKS 892.3.3.1 Campus Principal 89

2.3.3.1.1 MDF 892.3.3.1.2 Rackde servidores 89

2.3.3.2 Campus Caamaño 1 912.3.3.3 Campus Caamaño 2 912.3.3.4 Campus 6 de Diciembre 912.3.3.5 Campus Expo Centuri 91

2.3.3.5.1 MDF 912.3.3.5.2 SDF 92

2.3.4 SISTEMAS DE TIERRA 932.3.5 CANALIZACIONES 93

2.4 ANÁLISIS DE LAS APLICACIONES MANEJADAS, SU TRÁFICO Y LAASIGNACIÓN DEL ANCHO DE BANDA ACTIJAI 94

2.4.1 APLICACIONES 942.4.2 ANÁLISIS DEL TRÁFICO Y ANCHO DE BANDA DE LA RED 962.4.2.1 Enlace a Internet 96

2.4.2.1.1 Tráfico entrante (desde Internet hacia la red) 982.4.2.1.2 Tráfico saliente (de la red hacia Internet) 100

2.4.2.2 Tráfico de la red interna de datos 1022.4.2.2.1 Tráfico en los enlaces y carga en los servidores 1032.4.2.2.2 Tráfico por aplicaciones 105

2.5 DETERMINACIÓN DEL NÚMERO DE USUARIOS DE LA RED 1072.5.1 RED ADMINISTRATIVA 1072.5.2 RED ESTUDIANTIL 108

Page 5: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ÍNDICE IV

2.5.3 IMPRESORAS 1092.6 ANÁLISIS DE LA RED DE VOZ 110

2.6.1 DESCRIPCIÓN DEL EQUIPO TELEFÓNICO 1122.6.2 ANÁLISIS DEL TRÁFICO DE LA RED DE VOZ 1162.6.3 SÍNTESIS DE LA RED TELEFÓNICA 124

2.7 EVALUACIÓN DE RENDIMIENTO DE LA RED ACTUAL 1262.7.1 UBICACIÓN 1262.7.2 DISPONIBILIDAD 1272.7.2.1 Enlaces de interconexión entre campus 1272.7.2.2 Servidores 1282.7.2.3 Red de voz 1292.7.3 RENDIMIENTO 1292.7.3.1 Equipos de red 1292.7.3.2 Estaciones de trabajo 1302.7.3.3 Red de voz 1302.7.4 ESCALABILIDAD 1312.7.4.1 Red de datos 1312.7.4.2 Red de voz 1322.7.5 SEGURIDAD 132

CAPÍTULO 3.REINGENIERÍA DE LA RED INTEGRADA DE VOZ Y DATOS 1343.1 ESTUDIO DE LAS PROYECCIONES DE CRECIMIENTO DE LAINSTITUCIÓN 1343.2 POLÍTICAS EN LA RED 1353.3 ANÁLISIS DE REQUERIMIENTOS 136

3.3.1 RED DE DATOS 1373.3.1.1 Campus Principal 1373.3.1.2 Campus Sede Norte 138

3.3.1.2.1 Distribución física de las áreas de trabajo 1383.3.1.2.2 Grupos de usuarios 1393.3.1.2.3 Aplicaciones 1403.3.1.2.4 Cableado estructurado 141

3.3.2 REQUERIMIENTOS DE VOZ 1463.3.2.1 Número y tipo de usuarios 1463.3.2.2 Proyecciones de crecimiento 1473.3.2.3 Determinación del número de circuitos troncales hacia la PSTN y red.celular 149

3.4 DISEÑO DE LA RED INTEGRADA DE VOZ Y DATOS 1513.4.1 MODELO DE RED 1513.4.1.1 Capa de acceso 1523.4.1.2 Capa de distribución 1523.4. U Capa de core 1533.4.2 PREDICCIONES DE TRÁFICO POR GRUPOS DE USUARIOS 1533.4.3 SELECCIÓN DE LA TECNOLOGÍA DE RED 1553.4.4 DISEÑO DE LA RED PASIVA 1573.4.4.1 Distribución de puntos de red 157

3.4.4.1.1 Ubicación de cámaras IP 1573.4.4.1.2 Determinación del número de puntos de red totales 158

3.4.4.2 Diseño del sistema de cableado estructurado 1593.4.4.2.1 Diseño del cuarto de telecomunicaciones 160

Page 6: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ÍNDICE V

3.4.4.2.2 Diseño del cuarto de equipos 1613.4.4.2.3 Cableado horizontal 1623.4.4.2.4 Cableado vertical 1633.4.4.2.5 Etiquetación 1633.4.4.2.6 Canaletas 164

3.4.5 DISEÑO DE LA RED ACTIVA 1653.4.5.1 Estaciones de trabajo 1653.4.5.2 Servidores 165

3.4.5.2.1 Determinación del número de servidores 1653.4.5.2.2 Características de los servidores 169

3.4.5.3 Equipos activos de red 1703.4.5.4 Telefonía IP 172

3.4.5.4.1 Gateway de voz 1723.4.5.4.2 CallServer 174

3.4.5.5 Cálculo del tráfico total por planta 1743.4.5.5.1 Tráfico generado por VoIP 1743.4.5.5.2 Tráfico generado por las cámaras IP 1783.4.5.5.3 Tráfico total por planta 179

3.4.6 DISEÑO DE LA RED INALÁMBRICA 1813.4.6.1 Áreas de cobertura 1813.4.6.2 Tipos de aplicaciones a emplearse 1813.4.6.3 Material de la infraestructura 1823.4.6.4 Conexión de la WLAN con la red cableada 1823.4.6.5 Número de usuarios 1823.4.6.6 Selección de la tecnología a emplearse 1833.4.6.7 Requerimientos de los equipos inalámbricos 1863.4.7 DISEÑO LÓGICO 1863.4.7.1 Diseño de VLANs 1863.4.7.2 Asignación de direcciones IP 1893.4.8 REDISEÑO DE LA RED DEL CAMPUS PRINCIPAL 1913.4.8.1 Tecnologías 194

3.4.8.1.1 Número de usuarios 3943.4.8.1.2 Niveles de tráfico de datos 1953.4.8.1.3 Rack de telecomunicaciones 195

3.4.8.2 Área de Inglés 1963.4.8.2.1 Requerimientos de los usuarios 1963.4.8.2.2 Niveles de tráfico de datos 1963.4.8.2.3 Rack de telecomunicaciones 197

3.4.9 ENLACE A INTERNET Y VPN 1973.4.9.1 Hnlace a Internet 1973.4.9.2 VPN 201

3.5 ELECCIÓN DE LOS EQUIPOS REUTILIZABLES Y DE LOS NUEVOSEQUIPOS 205

3.5.1 EQUIPOS DE RED 2053.5.2 SERVIDORES 207

3.6 SELECCIÓN DE LOS MEDIOS DE TRANSMISIÓN 2093.6.1 CABLEADO HORIZONTAL Y VERTICAL 2093.6.1.1 Cálculo del número de rollos de cable 2103.6.2 SELECCIÓN DE LOS RACKS 212

Page 7: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ÍNDICE VI

3.7 INGENIERÍA DE DETALLE DE LA RED DISEÑADA 2133.7.1 PRIMERA FASE: LEVANTAMIENTO DE LA SITUACIÓN DE LA REDACTUAL 2143.7.2 SEGUNDA FASE: DISEÑO DE LA NUEVA RED INTEGRADA DEVOZ Y DATOS 2163.7.3 TERCERA FASE: ELECCIÓN DE LOS EQUIPOS REUTILIZABLES.218

3.8 ADMINISTRACIÓN DE RED 2193.8.1 SISTEMA DE ADMINISTRACIÓN 2193.8.2 POLÍTICAS DE ADMINISTRACIÓN DE RED 220

3.9 SEGURIDAD DE RED 2203.9.1 FIREWALL f 2213.9.2 HERRAMIENTAS DE SEGURIDAD 2213.9.2.1 Active Directory 2213.9.2.2 ISAServer 2223.9.3 POLÍTICAS DE SEGURIDAD DE RED 222

CAPÍTULO 4.ANÁLISIS ECONÓMICO 2254.1 ALTERNATIVAS DE INVERSIÓN 225

4.1.1 RED PASIVA 2254.1.1.1 Canaletas y accesorios 2254.1.1.2 Tomas, cables y conectores 2264.1.1.3 Racks 2274.1.2 RED ACTIVA 2274.1.2.1 DATOS 2284.1.2.2 VOZ 2354.1.2.3 Análisis de alternativas 238

4.2 INVERSIÓN NETA O INICIAL 2394.2.1 INVERSIÓN COMÚN PARA LAS DOS ALTERNATIVAS 2394.2.1.1 Inversión en canaletas y accesorios 2394.2.1.2 Inversión en tomas, cables y conectores 2404.2.1.3 Inversión enracks 2414.2.2 INVERSIÓN DE LA RED ACTIVA 2414.2.3 OTROS EGRESOS 2454.2.3.1 Inversión para servicios de Internet y VPN 2454.2.3.2 Inversión en software para cámaras IP 2454.2.4 INVERSIÓN TOTAL.. 2454.2.5 COSTOS DE OPERACIÓN 2474.2.5.1 Costos de servicios 2474.2.5.2 Costos de personal 2474.2.5.3 Costos de mantenimiento de red 248

4.3 FLUJOS DE EFECTIVO 2484.4 EVALUACIÓN DEL PROYECTO 251

CAPÍTULO 5.CONCLUSIONES Y RECOMENDACIONES 2525.1 CONCLUSIONES 2525.2 RECOMENDACIONES 257

Referencias Bibliográficas 259

Page 8: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ÍNDICE VII

TOMO IIANEXO ADISTRIBUCIÓN DE AULAS Y OFICINAS EN LOS CAMPUS DE LA UDLA.ANEXO BDESCRIPCIÓN TÉCNICA DE LOS EQUIPOS DE RED.ANEXO CINFORMES DEL ANCHO DE BANDA DEL ENLACE A INTERNET.ANEXO DANÁLISIS DE TRÁFICO EN LOS ENLACES DE INTERCONEXIÓN.ANEXO EANÁLISIS DE TRÁFICO Y CARGA EN LOS SERVIDORES.ANEXO FNÚMERO DE PUNTOS DE RED, HOST E IMPRESORAS DE LA RED ACTUAL PORDEPENDENCIA.ANEXO GDISTRIBUCIÓN ACTUAL DE PUNTOS DE RED.ANEXO HDISTRIBUCIÓN FÍSICA DE LAS PLANTAS DEL CAMPUS SEDE NORTE.ANEXO IAPLICA IONES POR GRUPOS DE USUARIO DE LA RED DE LA UDLA.ANEXO JPERFILES DE LOS LABORATORIOS DE LA UDLA.ANEXO KDISTRIBUCIÓN FÍSICA DE LAS CÁMARAS IP EN EL CAMPUS SEDE NORTE.ANEXO LDISTRIBUCIÓN FÍSICA DE LOS PUNTOS DE RED EN EL CAMPUS SEDE NORTE.ANEXO MCOBERTURA INALÁMBRICA DEL CAMPUS SEDE NORTE.ANEXO NFUNCIONAMIENTO DEL SMS.ANEXO ODISTANCIA PARA LAS CONEXIONES DE FIBRA ÓPTICA PARA EL CAMPUSSEDE NORTE.ANEXO PPROPUESTAS ECONÓMICAS DE EQUIPOS DE RED ACTIVA Y PASIVA.

Page 9: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ÍNDICE VIH

ÍNDICE DE FIGURAS

Figura 1.1 Modelos de referencia OSIy TCP/IP 1Figura 1.2 Protocolos y redes en el modelo de referencia TCP/IP 3Figura 1.3 Hub 5Figura lAGateways 6Figura 1.5 Switches 7Figura 1.6 Roufer 8Figura 1.7 Área de trabajo 12Figura 1.8 Sistema de cableado estructurado 13Figura ].9 Notación específica de las implementaciones Ethernet 19Figura 1.10 Detección del canal virtual con CSMA/CA basada en MACA W 25Figura 1.11 Estructura de unaredFrame Relay 28Figura 1.12 Estructura de la trama Frame Relay 29Figura 1.13 Clases de direcciones IP y su formato 31Figura 1.14 Definición de subredes 34Figura 1.15 Formato del datagrama IP 35Figura 1.16 Formato del segmento TCP 36Figura 1.17 Elementos básicos de un software de administración de red 38Figura 1.18 MIÉ estándar 40Figura 1.19 Categorías de amenazas 43Figura 1.20 Estructura de una red con un firewalI hacia el exterior 46Figura 1.21 Túnel VPN a través de Internet 47Figura 1.22 Ejemplo de una división en VLANs 48Figura 1.23 Pila de protocolos del estándar H.323 52Figura 1.24 Arquitectura de un sistema de telefonía IP 53Figura 2.1 Diagrama topológico de la red de datos 64Figura 2.2 Distribución de servidores en el campus Expo Centuri 72Figura 2.3 Distribución de servidores en el cuarto de telecomunicaciones (campusPrincipal) 73Figura 2.4 Interconexión de campus de la UDLA 78Figura 2.5 Puertos existentes en elfirewall 79Figura 2.6 Distribución LAN en campus Principal 83Figura 2.7 Distribución LAN en campus Caamaño 1 y Caamaño 2 84Figura 2.8 Distribución LAN en campus 6 de Diciembre 84Figura 2.9 Distribución LAN en campus Expo Centuri 85Figura 2.10 Transceivery conectores ópticos 88Figura 2.11 Distribución de pines para RJ45 según la norma ANS1/TIA/EIA-568B 88Figura 2.12 Distribuidor Principal (MDF) 90Figura 2.13 Rack de servidores 90Figura 2.14 Distribuidor Principal (MDF) 92Figura 2.15 Distribuidor Secundario (SDF) 92Figura 2.16 Canaletas plásticas y metálicas 94Figura 2.17 Grado de utilización del enlace de entrada (bajada) a Internet 100Figura 2.18 Grado de utilización del enlace de salida (subida) a Internet 102Figura 2.19 Niveles de tráfico en los enlaces de cada uno de los campus 103Figura 2.20 Cantidad de información y tráfico promedio en los servidores 105Figura 2.21 Utilización por aplicaciones 106

Page 10: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ÍNDICE IX

Figura 2.22 Ubicación de las centrales telefónicas en los campus 111Figura 2.23 Horas de tráfico pico de las centrales telefónicas 121Figura 2.24 Porcentaje de utilización de líneas troncales y extensiones de la UDLA 125Figura 3.1 Crecimiento anual del personal 134Figura 3.2 Cobertura de la red inalámbrica en el campus Sede Norte 143Figura 3.3 Proyección de extensiones 148Figura 3.4 Modelo jerárquico de red 153Figura 3.5 Tecnologías LAN empleadas 156Figura 3.6 Distribución de los espacios de telecomunicaciones 161Figura 3.7 Distancia máxima para el cableado horizontal 162Figura 3.8 Topología de los elementos de la telefonía fP 174Figura 3.9 Formato del paquete de VoIP 175Figura 3.10 Cabecera CRTP 176Figura 3.11 Datagrama IP con CRTP multiplexado con tunneling 176Figura 3.12 Trama Ethernet 178Figura 3.13 Topología de red en el campus Principal 194Figura 3.14 Interconexión entre campus 203Figura 3.15 Esquema topológico de la red integrada de voz y datos de la UDLA 204Figura 3.16 IBMeServer BladeCenter 208Figura 3.17 Tarjeta HS20Xeon EM64T 208Figura 3.18 UTP categoría 5e y conectar RJ 45 209Figura 3.19 Conectar LC para fibra óptica 209

ÍNDICE DE TABLAS

Tabla 1.1 Características de hubs 6Tabla 1.2 Conceptos importantes de los switches 7Tabla 1.3 Configuraciones de los servicios de los servidores 9Tabla 1.4 Requerimientos de puesta a tierra 18Tabla 1.5 Características de las implementaciones para Ethernet a JOO Mbps 20Tabla 1.6 Características de las implementaciones para Ethernet a 1000 Mbps 21Tabla 1.7 Tecnologías de redes LAN inalámbricas 22Tabla 1.8 Estándares IEEE 802.11 26Tabla 1.9 Rango de las direcciones IP de acuerdo a su clase 32Tabla 1.10 Número de redes y ordenadores en las principales clases de direcciones IP... 32Tabla 1.11 Rango de direcciones IP privadas 32Tabla 1.12 Formato de la máscara de subred 33Tabla 1.13 Ejemplo del uso de la máscara de subred 34Tabla 1.14 Ejemplo de la definición de subredes 34Tabla 1.15 Tipos de PDU SNMPvl ySNMPv2 40Tabla 1.16 Campos básicos de un certificado X. 509 45Tabla 1.17 Conjunto de protocolos de H.323 51Tabla 1.18 Tipos de gateways 53Tabla 2.1 Equipos presentes en los campus de la UDLA 62Tabla 2.2 Sistemas UPS presentes en el cuarto de telecomunicaciones 63Tabla 23 Características de los servidores alojados en el campus Principal 66Tabla 2.4 Funciones de los servidores alojados en el campus Principal 67Tabla 2.5 Características de las computadoras de los laboratorios 74

Page 11: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ÍNDICE X

Tabla 2.6 Características de las estaciones de trabajo 74Tabla 2.7 Direccionamiento IP para la LAN Privada 75Tabla 2.8 Direccionamiento IP de los servidores 76Tabla 2.9 Direccionamiento IP para los segmentos en la red pública 77Tabla 2.10 Interconexión entre campus 78Tabla 2.11 Equipos presentes en el cuarto de telecomunicaciones 82Tabla 2.12 Equipos presentes en los campus de la UDLA 86Tabla 2.13 Características del cableado vertical 87Tabla 2,14 Aplicaciones generales para el sector administrativo 95Tabla 2.15 Software antivirus para los sectores administrativo y estudiantil 95Tabla 2.16 Aplicaciones para laboratorios del sector estudiantil 96Tabla 2.17 Medición del tráfico entrante de Internet 98Tabla 2.18 Medición del tráfico pico entrante de Internet 99Tabla 2.19 Medición de la utilización del enlace de entrada (bajada) de Internet 99Tabla 2.20 Medición del tráfico saliente a Internet 100Tabla 2.21 Medición del tráfico pico saliente a Internet 101Tabla 2.22 Medición de la utilización del enlace de salida (subida) a Internet 101Tabla 2.23 Tráfico total en cada uno de enlaces a los campus 103Tabla 2.24 Análisis sobre los servidores 104Tabla 2.25 Porcentaje de utilización por aplicaciones 106Tabla 2.26 Número de usuarios de la red administrativa 107Tabla 2.27 Número de usuarios en la red estudiantil del campus Principal 108Tabla 2.28 Cantidad de host, impresoras y punto de reden la VLAN administrativa 109Tabla 2.29 Cantidad de hosí, impresoras y punto de reden la VLAN estudiantil 110Tabla 2.30 Niveles de servicio telefónico 111Tabla 2.31 Dispositivos telefónicos del campus Principal 113Tabla 2.32 Descripción de las tarjetas de la central telefónica KX-TA308 114Tabla 2.33 Descripción de las tarjetas de la central telefónica KX-TAIOO 114Tabla 2.34 Dispositivos telefónicos del campus Expo Centuri 115Tabla 2.35 Descripción de las tarjetas de la central telefónica KX-TEM824 115Tabla 2.36 Dispositivos telefónicos del campus 6 de Diciembre 115Tabla 2.37 Descripción de las tarjetas de la central telefónica KX-TA616BX 116Tabla 2.38 Intensidad de tráfico de la central telefónica del campus Principal (Ceñirá!KX-TA100) '. 117Tabla 2.39 Intensidad de tráfico convencional del campus Principal (Central KX-TA308)

118Tabla 2.40 Intensidad de tráfico convencional del campus Expo Centuri 119Tabla 2.41 Intensidad de tráfico convencional del campus 6 de Diciembre 120Tabla 2.42 Horas de tráfico pico de las centrales telefónicas 121Tabla 2.43 Número de circuitos convencionales recomendados 122Tabla 2.44 Intensidad de tráfico celular en el campus Expo Centuri 123Tabla 2.45 Circuitos celulares recomendados 124Tabla 2.46 Lineas troncales totales en la UDLA , 324'Cabla 2.47 Ocupación de líneas troncales y extensiones convencionales de la UDLA .... 125Tabla 2.48 Líneas troncales existentes y recomendadas 126Tabla 2.49 Escalabilidad de los equipos de red en campus Principal 131Tabla 2.50 Escalabilidad de los equipos de red en la UDLA 131Tabla 3.1 Descripción de aplicaciones 141Tabla 3.2 Nomenclatura de los grupos de usuarios 143

Page 12: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ÍNDICE XI

Tabla 3.3 Requerimientos de puntos de red para el campus Sede Norte 144Tabla 3.4 Distribución del número de extensiones telefónicas 146Tabla 3.5 Requerimientos del sistema telefónico 147Tabla 3.6 Proyección de extensiones a 5y 10 años 148Tabla 3.7 Proyección de extensiones a 5y 10 años enfundan del índice de crecimiento delpersonal administrativo 148Tabla 3.8 Proyección de lineas troncales convencionales a 5 y 10 años 149Tabla 3.9 Proyección de líneas troncales celulares 5y 10 años 150Tabla 3.10 Ancho de banda por aplicación 154Tabla 3.11 Ancho de banda por grupo de usuario 155Tabla 3.12 Ubicación de las cámaras IP en el campus Sede Norte 157Tabla 3.13 Número totales de puntos requeridos por grupo de usuarios 159Tabla 3.14 Distancias máximas para el cableado dorsal 163Tabla 3.15 Código de color para el cableado 164Tabla 3.16 Requerimientos de las estaciones de trabajo 165Tabla 3.17 Características de los equipos activos de red 170Tabla 3.18 Número de switches requeridos por planta 172Tabla 3.19 Características de los codees 173Tab\a 3.2Q Ancho de banda VoIP requerido en el enlace WAN 177Tabla 3.21 Ancho de banda VoIP requerido para LAN 178Tabla 3.22 Flujo de tráfico generado por grupo de usuarios 180Tabla 3.23 Proyección del número de usuarios inalámbricos en la Sede Norte 183Tabla 3.24 Distribución de usuarios inalámbricos a ¡O años 183Tabla 3.25 Ancho de banda requerido para WLAN 184Tabla 3.26 Atenuación de las señales inalámbricas para una frecuencia de 2,4 GHz 184Tabla 3.27 Nomenclatura a emplearse para los APs 185Tabla 3.28 Distancia de cada AP a su cuarto de equipos 185Tabla 3.29 Requerimientos de los accesspointpara la Sede Norte 186Tabla 3.30 Dominios de la nueva red 187Tabla 3.31 Subdominios 188Tabla 3.32 Direccionamiento IP de las VLANs 189Tabla 3.33 Direccionamiento ¡Ppara los subdminios 190Tabla 3.34 Direccionamiento IP para la granja de servidores 190Tabla 3.35 Usuarios de la red estudiantil para la academia de tecnologías 194Tabla 3.36 Tráfico de los usuarios para Tecnologías 195Tabla 3.37 Rackde telecomunicaciones para Tecnologías 195Tabla 3.38 Usuarios de la red estudiantil para el área de Inglés 196Tabla 3.39 Requerimientos de tráfico de los usuarios para el área de Inglés 197Tabla 3.40 Rackde telecomunicaciones para el área de Inglés 197Tabla 3.41 Tráfico requerido para el enlace a Internet 198Tabla 3.42 Ancho de banda estimado para la VPN 203Tabla 3.43 Características de los equipos de red existentes 205Tabla 3.44 Equipos de redreutilizables 207Tabla 3.45 Número de rollos de cable para el cableado horizontal 212Tabla 3.46 Dimensiones de los racks de telecomunicaciones para Sede Norte 212Tabla 4.1 Capacidad de las canaletas comerciales 225Tabla 4.2 Cantidad de canaletas y accesorios a emplearse 226Tabla 4.3 Cantidad de conectares, cable y tomas de datos 227Tabla 4.4 Cantidad de racks y sus componentes 227

Page 13: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

AN EXO A

DISTRIBUCIÓN DE AULAS Y OFICINAS ENLOS CAMPUS DE LA UDLA.

Page 14: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

Campus Principal

Planta baja:

- Admisiones

- Archivo

- Biblioteca

- Oficina del Presidente de la Asociación Estudiantil, ubicada en un

cubículo compartido en la Biblioteca

- Servicio de copiadora

- Dirección Académica

- Jefe de Control de Registro Tecnológico

- Jefe de Secretaría Académica y Registro Curricular

- Laboratorio de Audio y Video

- Laboratorio de Computación 5A

- Laboratorio de Computación 5B

- Laboratorio de Computación 6

- Laboratorio de Computación 7

- Recepción

- Registro Curricular

- Tres aulas de clase (Salas 2, 3, 4)

- Sala de Profesores

- Secretaría Académica

Planta alta:

- Caja

- Centro de Cómputo

- Laboratorio de computación 20

Laboratorio de computación 21

- Laboratorio de computación 22

- Oficinas de Sistemas

- Siete aulas de clase (Salas 23, 24, 25, 26, 27, 28, 29)

Page 15: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

Campus Caamaño 1

- Planta baja:

- Servicio de Copiadora e Impresión

- Dirección de Arquitectura de Interiores

- Librería

- Aulas de clase (Salas 80 y 81)

- Planta alta:

- Bodega

- Coordinación de Educación Parvularia

- Cuatro aulas de clase (Salas 82, 83, 84 y 85)

Campus Caamaño 2

- Subsuelo: Taller de Sonido.

- Planta baja:

- Coordinación de Ciencias Físicas y Matemáticas

- Decanato Ingeniería y Ciencias Agropecuarias

- Dirección de Escuela de Comunicación

- Secretaría Académica

- Taller de Arquitectura

- Dos aulas de clases (Salas 63 y 64)

- Planta alta:

- Coordinación Publicidad, Diseño y Multimedia

- Coordinación de Sistemas, Ingeniería Agropecuaria y Medicina

Veterinaria

- Coordinación Comunicación Corporativa

- Cuarto de Equipos de Comunicación

- Taller de Arquitectura

- Dos aulas de clase (Sala 66 y Sala 67)

Page 16: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

Campus 6 de Diciembre

Edificio Frontal

- Subsuelo: Aula de clase 30.

- Planta baja:

- Decanato Ciencias Económicas y Administrativas

- Club de Economía

- Coordinación de Economía y MDD (Maestría en Desarrollo y

Descentralización)

- Dirección Asuntos Estudiantiles y Deportes

- Coordinación de Hotelería y Turismo

- Oficina Sala 43

- Oficina Sala 44

- Recepción

- Planta alta:

- Coordinación de Formación General

- Dirección de Formación Integral

- Dirección de Idiomas

- Orientación Vocacional y Apoyo Psicológico

- Cuatro aulas de clase (Salas 31, 32, 33 y 34)

Edificio Posterior

- Planta baja:

- Coordinación de Administración y Finanzas

- Servicio de copiadora

- Secretaría Académica

- Cinco aulas de clase (Salas 50, 51, 52, 53 y 54)

Page 17: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

- Primera planta:

- Coordinación Escuela de Tecnología

- Tres aulas de clase (Salas 55, 56 y 57)

- Segunda planta:

- Coordinación de Comercio Internacional

- Coordinación de Marketing

- Dos aulas de clase (Salas 58 y 59)

- Tercera planta: Laboratorio de Fotografía.

Campus Expo Centuri

- Admisiones

- Dirección Académica

- Finanzas y Contabilidad

- Maestrías

- Servicios y Compras

- Rectorado

Page 18: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

ANEXO B

DESCRIPCIÓN TÉCNICA DE LOS EQUIPOSDE RED.

Page 19: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

EQUIPOSACTUALES

Page 20: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3COM® BASEL1NE SWITCHES DATA SHEET

Ports - Autosensing

LED Indicdtors

802. 1p TrafficPriontization(Pnority Queuing)

MAC Addresses

3COM BASELINESWITCH 201 6

3C1R470

16 '0/100Ethernet

Power, Networktrafíic/Duplexmode, Linkstatus/Speed

N/A

4,000

3CQM BASELINESWITCH 2024

3C 16471

24 10/100Ethernet

Power, Networktraffic/Duplexmode, Linkstatus/Speed

N/A

4,000

3COM BASELINESWITCH 2126-G

3C16472

74 10/1 00 and2 10/100/1000Ethernet

Power, Networktraffic/Duplexmode, Linkstatus/Speed

N/A

4,000

3COM BASELINESWITCH 2808

3C16477A

8 10/100/1000Ethernet

Power, Networktraffic/Duplexmode, Linkstatus/Speed

4 queues onevery port

8,000

3COM BASELINESWITCH 281 6

3C 1 6478

16 10/100/1000F.thernet

Power, Nelworktraffic/Duplexmode, Linkstatus/Speed

4 qusues onevery port

32,000

3CQM BASELIN^HSWITCH 2824 ^1

^C 16479

2410/100/1000Ethernet

Power, Networktraffic/Dupíexmode, Linkstatus/Speed

4 queues onevery pon

32,000

MDI/MDIX- / / / S •/ /Automaticconfigurationon a II ports

ForwardingMethod

Store a Forward Store & Forward Store & Forward Store a Forward Store & Forward Store & Forward

POWERFUL ADVANCED SWITCHING

Gigabit performance (3C16472, 3C16477A,3C16478, 3C15479}

Descríption

CtMinect to servers and desktops running at 10, 100, or IODO Mbps. 48 Gbps switching capacity supportshighest speed servers and desktops without jdditional network investment.

Baseline switches opérate at full wirespeed on aíl ports, delivering unimpeded access tonetworked resources.

Cost-effective 10/100/1000 connections

SIMPLE INSTALLATiON AND USE

Auto MOI/MDIX ports

Range of port densities provides expansión for growing srnall businesses at a very affordable price per port.

•••••••••••••••••••••Simplify installation by eliminating common cabling errors. automatically detecting íhe type of Ethernetcable used—strsight-through or crossover.

Pre-configured setup Makes sure that switches work "right out of the box" with no configuration or managementsoftware needed.

Easy-to read front panel LEDs Give at-a-glance status and network information to simplífy diagnostics and troubjeshooting.

Consisient form factor

RELIABLE

Sturdy, dependablo dcsign

Complete support p(i(.ksge

Clean design, standard 1RU enclosure optimizes rack space.

3Com delivers premium-quality. reliable networking products that stay up and running year aflsr year.

Limited Lifetime Hardware Replacement provides peace of mind.

Page 21: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3CQM» BASEUNE SWfTCHES DATA SKEET

Total Ports3CI6470: 1G autosensiiifí 10/100

3CI6471: 24 autoscnsing 10/100

3C16472: 24 autuscnsing 10/100 and 2 autnsriising10/100/1000

3CL6477A: 8 autosensing 10/100/1000

3C16478: 16 autoseiising 10/U)()/IOOO

JC16479: 24 autostrnsing 10/100/1000

Standards ConformanceISO 8802-J

IFEE 802.3 fEthernct)

1EGE 802. iu [Fast F.thernct)

lHEE8lí2.Ut (bridging)

IF.EE 8l>2.3x (flnw control)

IliEL 802.3ab (Gigabit Ethernet)

IFiEE 802.Ip ¡traffic prioritization)

Media tnterfaces10/100/1OOOBASE-TX/RJ-4Ü

MAC Addresses3C16-170. 3CI6471, 'KM 6472: 400O

ÍCI(,477A: WK>0

3C16478and 3Clfi479: 32,000

Ethernet Swrtching FeaturesWirt-spccd, nun-Hockiiip I.ayer 2 switcliiiig; Sloi-e-anJ-lbrward íbrwarding; Pull-/half-dupU-xamo-ncgoliation; HÜ2.1p liafTit priuritizationjpriority cjiíruing)

Electrieat Power

Power inlet; IEC 320

AC Une frequency: 47/63 Hz

Input valtage: 100-240 VAC

Curren t rating: 1A fmax)

Máximum power tonsumption:3C16470 I5W.3CI6471 20W,3CI6472 - 12.5 W3C16477A 9.96 W,3C1647B 26.3 W,3C1(>479 3Ü.04W

Máximum power disítpation:3C16470 52 BTt'/hr.3C1G471 68IiTU/htr

3016472-42.^6 HTU/hr3C16477A 34.02 BTU/hr,«:if.478 89.8 BTU/hr,X!lfi479 119.7 HTU/hr

LED IndicatorsPower, Network trafile/Dúplex mode,Link status/Speed

Operatíng Temperature:OnKj40"C(32°U> 104°FJ

Humidity: 10 tn 90% (non-condcnsing)

SafetyUL 1950. EN 60950, CSA 22.2 ff930 1EC 60950

Emissions

EN 55022 Class A, FCC Pan 1 "i Subpait 11 Class A,ICES-O03 Class A, VCCI Class A,

AS/NZS 3548 CUwt A. CNS 13438 Class A

EnvironmentalEN 60068 flEC 68)

(mmunityEN 53024

Physical Dimensionsticight: 4.4 an(1.7in)

Dcpth: 17.icm(6-8in)

Weight: JC1M7O, 3CI6471 and 3C 16477 A l-í kg(3.07 Ib);

3C16472-1.6Kg[?.?21b)

1C16478 I.«7kg(4.121b): 3C16479 1.% kg (4.32 Ib)

Package ContentsliaseliucSwitrh

Kubbei- fcct

Rack-mounl kil

Dser's guidc-

WarrantyLimited t.ifetimc Hardware Replacemcnt

Olher Service Bciiefíts: Advancc hardware replacement vvitli snmt- day sliipmciil Jbr Korth Airicncs andWfstiírn humpo. Ncxl day shipmenl fnr rut.1 of world.Calis musí bt rcccivt'd by publishcd cul-ulí times.

90 days df tfleplioiic lechnical suppon, l.imilcd suClware updates.

Se».1 ww\v. 3com.com/warraiity for mtiru dciail.

Kcgistcr productü al lit(p://cSupporl. Jcom.com/

Page 22: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3COM* BÁ5EL1NE SWITCHES DATA SHEET

All Baseline switches include:

• Plug <md play simplicity

• No configuration required

• Compact IRU-high endnsure

Easy installatioii and upgrade rackmounting kit

t-rce-standiiig ar 19-inch rack-mountcdoperation

PRODUCT DESCR1PTION

3Com Baseíine Swítch 2016

3COM SKU

3C16470

3Cüm Baseline Switch 2024 3C1G471

3Com Baseline Switch 2126-G 3C16472

3C16477A

3Com Baseline Switch 281 (i 3C16478

3Com Baseline Switch 2824 3C1G479

íf nm C oinoratian, Corpurate Headquarteis, 350 Cdmpus Dnve, Míiriborough, MA 01752-3064

To learn more about 3Com solutions, visit w/vwv.Bcom corn. 3Com is putihdy ti^cíwl mi NASDAQ unoer the symbol COMS

scom

Page 23: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

scom

3Com® SuperStack® 3 Switch 3300Expandable Configuration

KeyBenefíts For Expanding Existing InstallationsThe 3ComK SuperStack* 3 Switch 3300expandable configuralion models arebest suited for installing into existingsites with other Switch 3300 orSwitch 1100 models.

Expandability

Choose from six modules, iucludingfiber Ethernet, Gigabit Ethernet (fíberand copper), and í.ayer 3 capabüities.

Flexibifity

Choose from two models, alluwingyou to créate the optimum 10/100/1000switching Configuration.

Stackability

Stack up to four switches tugether—in any combination—to créate onevirtual switch.

Stackíng Compatibility

These switches work with yourexisting 3Com SuperStack II Switch1100/3300 units, including thc fixedConfiguration Switch 3300s.

Lifetime Limited WarrantyRnsures peace of mind. Indudesfan and powcr supply. Seowww.3com.com/warranty for details.

The SuperStack® 3Switch 3300 is aproven solution for10/100 switching.

SupcrSlack 3 Switch .1300 expandableconfiguración stackable switche.s have along history of highly reliable 10/100switching. Thesc units are best suitedtoday for extending existing siteshaving other Switch 3300 orSwitch 1100 models, or for sparingin existing installations. All switchesinclude expansión eapabilities, soyou're ready for future growlh wheiin ceded.

Tliis expansión slot can próvidoadditionaJ tcchnology sucli as Laycr 1capabilities, allowing yt>u to increascnctwork performance or provideaccess to high-spced Gigabit Hthernetconnections. With thcse modules,you can tailor each modular Switch3300 to your speciííe requirements atminimal cost.

As with the ííxed confjgurationSwilch 3300s, all models are í'ullymanageíiblc out of the box. If youwant to exlend managcment acrossthe network, you can use trial copyof 3Com Network Supervisor.

For new installations looking for amanaged 3Com switch withexpandable options, consider alsothe SuperStack 3 Switch 4400 family,with muIti-layer trafile classification,log-in security, and staeking up tn192 10/100 porls. For dctails, go towww.3com.com/4400.

Page 24: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Autosenslng Stackíng Connector Module10/100 Mbps Ports (Matrix Port) Slot

SuperStadc 3 Swilch 3300

SuperStark 3 Switch 3300

12 1

2-1 1

1

1

All switches ínctude:• Pt>licy cnforcement with 1-ast [R KiMP snooping,

1BEE 802.ID fincorporatiiig 802. Ip prioriti-zarion), and IKl-li 802.1Q standards-basedVLANs

• Dual qiicucs to hclp prioriti?.c multimedia iraffic

• Mullicas! ültering using KíMP snouping/t!MRPfur more cífícient bandwidth ulilizalion forhandling video trafile

• Elastic porl buffering for un-the-fíy port buíTcrmemory allocatiun, enabling automaticperformance optimizaron based on nctworktrafile

• Statidards-hased flow control to maximízcperformance and minimize packct Joss underheavy iietwork luading

Trunking support to aggiegate liíiks into asingle higli-sjWL'd coniicctjon to othcr switchesor backbone networks

Automatic detection of full-^h^lf-duplcxoperaiion on all ports to maximize performancewithoui manual coiiíigm.itioii

10/100 ports with auiosensiug on all porrs tr>adjust autómata-ally to thc spced of the attacheddevices

Web-based monilorin¡> and control system,t'mbfddcd Remóte Mouitoriii£ fRMON}, and3Cotn Nelwork Supervisor [trial copy). ciiablingauthoriztíd adminisirators to troublcshoov andconfigure a swilL'hiug stack framauy lucaticín

Full support of rcsiJiciit links and spanning trcc,as well psoptional redundan! power supplii's

Gigabit EthernetThcM Lngabit 1-thcrnct modules support high-pei formalice, fault-toltrant intcrworkgroup andwi)rkgn)up-to-backbone counections. The easy-Ui-install modules provide full-duplex GigabitEthernet up to 2 Gbps tliraughpur, eliminatingnct\vi>rk bottlenecks. They support both 802.1Dspanning trce and it'silíenl links,

• Thf KWOBASli-T module offers a Category :"«copper interface over distances up lo 1OO melers.

• The HK1[>BASl;-SX module oITers a muhiinodeliht-j ÍTiteifatt; over distances up to 330 mctcrs.

• Thc lOOOBASK-I.X module otters muliimodt- andsinglc-mode übcr ¡nttrfaccs over distanct;-.certified hy ÍCom up to 10 kilomelers.

Fast EthernetThese modules add a fiber last Ktliemet luckbouelink to your switchc-d workgixiup, Thc easy-io-inslall modules provide full-duplex 200 Mbpsthrouglipllí ovi'i' disianct'S up lo 2 kilomctris of fiber.

• Thc 100BASE-HX du.i! poit module is au exccllentchcicc for rcsiliciit comiectionf. in misMuu-crítical

iielwurks or when múltiple fiber bai khonccunneclions are needt;d to and from the Mack.

• The ¡OOBASE-FX single nort module is a lowercost optioii whc'ii a single high-specd bntrkhoncluik can I ir sliarcd by múltiple units in thc sl.ick-

Layer3The l,ayer i module lets you aist eííecUvely addroutÍJig capabilities to yí""" switched I O/100/1000Mbps workgroups ro bou»t inrraiict perfornunceand off-lnad legacy routers of LAN trafñc. It allowsany 1100 or J10O modular unit to seamlessly mutt-1P traffir betwetn subnets in addttiun lo switcliinjiIPS, ApplnTalk. and othcr Itgacv protocols. Onemodule can manare routing for thc cutiré stack.

• Extcnsivc standards-based routing protón.»]support (including R1P ft OSPI-} allows (heswitches to opérate in ntiy neuvorkingcnviitínmeiit.

• líistauce Vector MultkAst Routing t'miorol(I>V"MR1*) optimizes multimedia trafile lardolí ver y.

SupcrStarfc i Swilcíi .Í3t)l) 12 10/100 portsÍCI MR 1 A'

SupcrStack 1 Svvitfh ÍJOO 24 10/100 ports.ÍCI6980A'

SupcrStai'k Ií Switch 1100/noo 100011ASÜ-TModule 3C16978

SuperStack U Swilcli J 100/'VÍOO J OOOKASI- SXModule K1697 3

SupcrStark II Switch 1100/3300 IOOOBASH-LXModule :íClf,Q7>

SupeiStack II Svviti-h 110O/.tiOOMdduk-. single port _^ K'lft*i70

Supi.-i.SUrk II Switch 1100/HOO J(X»BASI:.-t-XModule.dual port 3CK.971

SuperSuirk II Switch 1100/iiOO M . I I I Í X Module3C16MQ

Supei-Stjfk 11 Switch Matrix Cablu KMb'lbS'SuperStack 11 Switch 1100/3300 modules andaccessorit's can be used on SuperStack 1Switth 3300s.

scom

SCorn Corporation, Corporate Hpaclqu¿irtE3rs, 5500 Greái Amero Parkway, P.C. Box 03145. Sanls Cbra. CA 9bOü2-81415

To learn more übouí 3Corn solirtior.s, visit w\w«.-3rom.com. 3Coni Corporoíion ¡s publicly traded on f-JASDAQunder thc- üymbo! COMS.

Copyright íí 2003 3Com Corpoimioii. Al) righls íescivcd. 3fcnn. ihe 3Corn logo, ,ind SupeiSt.ic'k are icgiiicred tr.idcmarksof iCom Coi-pui-acion. ApfileTalk is a cradcmatk of Appie Computct. Ail olhci i-ompuny JJiif pradnri n.imcs inay be-tradcmackt of th f i r i-cspccli'.'c companics. Wl i í lr every cfffií't is niadc tn É-IKUI-C thc jnfomialiojí ^ivcn is JCturJlc.3C»m doM nm nccí-pt liabiliiy fot any frrors PI mistakcs which may arisc Spprific.nioní -ind flthcr ¡nfnnuatirtn 111 tlusdcievimcnt injy be sulijcn rn rhangc wítlioin nctirc. 4Üi)f>ííi-(Hifo 07^'iii

Page 25: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

scom

3Com« SuperStack* 3 Switch 3300Fixed Configuration

Key Benefits AffordableThe SCom'SuperStack' 3 Switch 3300reduces the cost of migrating toGigabit Hthernet, so any size businesscan enjoy high-speed technology.

Plug-and-Play Símplicity

Each model is optimized and precon-figured for your necds.

FlexibilityChoose írom four models, allowingyou to créate the optimum configu-ration of 10/100/1000 switching.

Advanced Stackability

Stack up to four switches together—in any combination—to créate onevirtual switch.

Investment ProtectionThe new switches work with yourexisting SuperStack II Switch1100s/3300s, so you can mix andmatch any 3300 switch in one stack.

Easy Management3Com* Network Supervisor isincluded with every unit. Thispowerful application lets youdiscover, map, and monitor yournetwork with case.

Lifetime Limited WarrantyEnsures peace of mind. Includes fanand power supply.

The SuperStack' 3Switch 3300 offersaffordable, high-speed switchingwith unparalíeledease of installationand support

Introduce the puwer and performanceof Gigabit Ethernet into yournetwork. 3Com has toppled thebarriers of artiíicially high pnces andneedlcss complexity. The newSuperStack 3 Switch 3300 offersplug-aud-play simplicity as well asthe lowest price per port for GigabitEthernet.

Until now, Gigabit Ethernet was tooexpensive for most small- and mid-sized businesses. Now, 3Com hasreduced the price of Gigabit Ethernetswitching, making it affordable forcompanies of any size.

3Com created four models—fullyoptimized and preconfigured soyou don't have to worry aboutspecifying and configuring hardwareand software. ,Iust open the box,connect the power cable and portconnections, and turn on the unit.All four modeJs are fully manageableout of the box. If you want to extendmanagement across the network, youcan use 3Com Network Supervisor atno extra charge.

Page 26: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3 C O M " S U P E R S T A C K B 3 SWITCH 3300 DATA SHEET

Autosensing Gigabit Gigabit10/100 Ethernet Ethernet StackingMbps ovar Fiber over Copper Connector ModulePorte 1000BA5E-SX 10OOBASE-T (Matrix Port) Slot

SuperStack 3 Swilch 3300 TM

SupcrStack 3 Switch 3300 SM

SuperStack 3 Switch 3300 XM

SuperStack 3 Switch 3300 MM

24

24 ' 1

24

24

1 1 Nú

1 •• No

i : NO3 No

10/100

Ethemet/Fast Ethernet Switching

SuperStack 3 Switch 3300 XM: The lowest priceper port memhcr of the SuperStack 3 Switch 3300family provides an exceUent entry poinl ií' yourbusiness is begínning tu impleraent 10/100switching.

SuperStack 3 Switch 3300 MM: A cost-cffcctivcswitching solution when combíning more thantwo SuperStack 3 Switch 33UOs together, using anintcgratcd matrix module, to créate tmc virtualswitcli of up to 110 switched ports that can beman age d as n single entity with a single 1P address(or multiplc IP addresses for added resiliente).

10/100/1000

Ethernet/Fast Ethernet/Grgabrt EthernetSwitchingSupcrStack 3 Switch 3300 TM a»d SupcrStack 1Switch 3300 SM: Both switches fcaturc an extraOigabit Fthcrnct port on the front panel for easyaccess. Use the 3300 TM to rcuse your existingcupper-based infraüinurlurc to itnplemenl tiijíabilEthcrnct. Use the 3300 SM for a fiber-basediiifrastructure. The SuperStack .1 Switch 3300 SMfeatures a IOOOBASE-SX MT-RJ port on theFront panel.

Alt switches Include:• Compact 1U high box (reduces unit heigltt by

onc-third)

• Policy ciiforcement wíth Fast IP, IGMP snooping,IEEE 802.111 (incorpurali ng 802.1 ¡t prioritization), and IKEE802.1Q standards-basedVLANs

• Dual queues to help prioritize multimedia traffic

• Mullicas t filteiing using KiMP snnoping/GMRP

for more efficient bandwidth utilization forhandling video traffic

• Elastic port buflcring for on-the-tly pon butícrmcmory alio catión, enabling automaticperfd mi a u ce ciptimi/atiun based on networktraffic

• Stnndards-based flow rontn»! to maximi/eperformance and minimize packet loss underhcavy network loadíng

• Truoking support to aggregate links into asingle high-spccd coimcction to othcr switchesor backbnne networks

• Automatic detection offull-/haíf-duplexopcration on all ports to maximize performancewithout manual configuration

• 24 10/100 ports with autosensing on all ports toadjust automatically to the spced of the attacheddevices

• Web-based monitoring and control systcm,embedded Remóte MtinÍloriiig(RMON), and3Com Network Supervisor, cnabling authunzcdadministrators to troublcshoot and configure aswitching stack from any location

• Ful) support of resilient links and spanning trec,as well as optiottal redundan! power supplks

Warranly and Other Support ServicesLifetinie limitcd w.irtanty, fot as long as ihi1

tiriginal Customer owns the pruduct, or fivc yearsafter product discontinuance, whichevcr occursfirst. Includes fan and power supply.

After rcgistering the product onlinc, othcr frecsupport serviccs such as telephone support, fasthardware replacement, and software updates mayalso he availablL-, depending un regional availabilílyand re tai le r partí cipation.

SuperStack 3 Switch 3300 XM24 IO/10O ports, 1 matrix connector

SuperStnck 3 Switch 33ÍWTM24 10/100 ports, 1 100ORASK-T port,1 matrix conneclor

SuperSlack 3 Swilch 330OSM24 10/100 ¡unís, I KHKÍBASH SX poit,1 niatrix caiinccUir

SuperStack 3 Sivítch 33OO MM24 113/100 ports, .1 nialrix auint:i;lors

Switch Matrix Cable

acom

3Cam Corporation, Corpurate Htaadquartcrs 5400 Baytront Plaza, P. O. Box 58145 Sania Clara, CA 95052-3145

To learn more about 3Com solutions, visit www.3com.cDm. 3Com Corporation is publícly traded on N^rtaq unrlprthe symbol COMS.

Copyright i"5 2002 ICom Cnrporatiun. All tighlb tcscrvcd. JC'om and SitperStacfc are rcgistcrcd t r adema rk-, of JComCorpiíratii>n. Tlie SCotn lago is a tratícmark cf iCom Corporation. All olhcr ciimpany and proilurt name^i may betradcmarks of their respective compnnirs. Whilp evtry efTort is made to ensure Ihe informa I uní givpn is accuiatc,3Com docs nnt accepr liabilily ior any crrors or mistakcs which may ansc. All spccifications are subjcct to changcwithout notitc. 400MM-001} 04/01

Page 27: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3COM* SUPERSTÁCK® 3 SWITCH 4400 FAMILY DATA SHEET

TOLL.Y

Tolly Ceriilied: Layer 2/4 Fast Ethernet Swilch

Performance Evaluation and Layer 2 InteroperabÜity.

For detaih, see www.3com.com/other/pdfs/ppoducts/

en US/SS4400 .tolly.pdf and www.3com.com/other/

pdfs/produtts/en_US/tally._tesl._440O.pdf, respective) y.

Totly Vcrificd for Switch Interoperability.

For detaiK, st»c

www.tolly.com/TVDetail.aspx?ProductID=93

3Com SuperStack 3 Switch 4400 familyswitches provide wirespeed 10/100 FastEthernet switching specifically designedfor Enterprise workgroup euvironments.This award-winning switch í'amily boastsadvanced QuaJity of Sei*vice features thatcan reduce the lalency of packetsthrough the network, with speciíictrafile priuritiy.ation improving thedelivery of converged data such as voiceand high quality video over IE

The switch family has great depioymentflexibility, with dual expansión slots tosupport a full mix of Fast Ethernet fíberand Gigabit Ethernet downlink modulesand stacking support of up to eightstacked units. Stacking reduces networkmanagement complexity by allowing upto 384 Fast Ethernet ports lo be managedas a single entity. The Switch 4400'shot-swappable stacking, with the abilityto inij.fiem.ent stack-wide aggregatedlinks, provides advanced resiliency formission critical networks.

Security is of utmost importance for anetwork, and the SuperStack 3 Switch4400 family is a strong contri butor to thisfor workgroups. IEEE 802. IX networklogin ensures all users are authorizedbefore being granted access to anynetwork resource. User authenticatioii iscarried out using any standards-basedRADIUS server, avoiding any proprietaryauthenticatión mechanisms.

3Com backs these products with morethan 25 years of networkirig experienee.They come with a Limited Lifetimeproduct hardware warranty.

The SuperStack 3 Switch 4400 SE 24-Port ¡3

an economical alíemative if advanced Layer 4

features are not needed inítially; a switch that

preserves the oplion of getting these features ¡n

the future.

The Switch 4400 SE lacks the trsffic dassification

and prioritization (satures of the other Switch

4400 family modets, while sharing the family's

performance, 5ecurity, stackability (with other

Switch 4400 SEs only), and available uplink

modules- Enablethe advanced features later with

the punchase of the SuperStack 3 Switch 4400 SE

Enhanced Software Upgrade.

SuperStack 3 Switch 4400s as aggregators; 3Com Switch

'lOxOs and SuperStack 3 Switch 4924s ¡n XRN Distnbuíed

Page 28: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3COM* SUPERSTACK* 3 SWITCH 4400 FAMILY DATA SHEET

PERFORMANCE

Switching CapadtyForwarding RateStore-and-Forward Switching

LAYER 2 SWITCHING

24-port .models, 8.8 Gbps; 48-port modeís, 13.6 GbpsForwarding rate: 24-port models, 6.6 Mpps; 48-port models, 10.1 Mppslatency <2,6 ps

MAC Address 8K MAC addressesSecute MAC addresses (256 addresses}

VLAN 64 VLANs (IEEE 802.10)

Link Aggregation IEEE802.3ad(LACP)Four trunk groups (up to four ports in each)Link Aggregation across stack

Auto-negotiation Auto-negotiation of port speed, dúplex, and cannection (MDI/MDIX)

Traffic Control IEEE 802.3x fulí-duplex -flow controlBack pressure flow control for half-dúplexBroadcast Storm Suppression (3,000 pps threshold)

Spanmng Trpp IEEE3Q2.1D SpanningTree Protocol (STPJIEEE 802.1W Rapid Spanntng Tree Protocol (RSTPÍ

• Fast-start mode• Spanning tree enabfe/disable per port

Multicast Snooping

STACK! NG

IGMP v1, v2, and v3 snoopingIGMP QuerierFiltering for 128 multicast groups

Stackmg

CONVERGENCE

Up to 384 portsSingle IP address for stack managementResifient loop backHot-swappable

Four hardware queues per portStrict priority queuingWeighted Round Robín queuing

Traffic CoS Marking / RemarkingIEEE 802.1p to DSCP mappingAuto ctassification of 3Com NBX* telephony trafficPriority based on:

• IEEE 802.1 p CoS• DSCP (DiffServ Code Point)• TCP/UDP source or destination port number• Default port priority• IP Address/Protocol

Traffic Shdpiny*

SECURITY

Networt: Access and User Securiíy

Egress rate limiting, port-based:• 1 Mhps increments (10/100 ports)* 8 Mbps increments (Gigabit ports)

Application and prototrol bfocking

IEEE 802.1X user authentication* RADIUS aulhentication* Advanced security by lucking a port to the MAC address of the authentfcated user* Automatically assign VLANs and QoS profile to a port based on user* GuestVLANoptkm

RADIUS Authenticated Device Access (RADA)* Authertticate devices based on MAC address agaínst a RADIUS server* Authenticate múltiple devices per port* Automatically assign VLANs and QoS to a port specific ío íhe devices attached* Operates alongside IEEE 802.1X authentication to ensure user and device are allowed access* Local authentication for upto fifty IEEE 802. IX usersand RADA devíces ¡n absence of a

centralized RADIUS server* RADA "whitelist" support enhances flexibílity for IEEE 802.1X/RADA deployment* Option to allow default VLAN access when RADIUS server is unsvailable

Disconnect Unknown Device (DUD)Access Control Lists (ACLs) allow or deny traffic based on specific subnet or individual IP addressPrívate Ports feature isolates edge ports at layer 2 to ensure user privacy.

Switch Management Local or RADIUS management of svvitch passwordsTrusted IP Management AddressesSyslogTelnet

*5SHv2(5Gbitor168bitDES)

• Switch 4400 5E requires 3Com SuperStack 3 Switch 4400 EnhaiiLed Software Upgrade, 3C17207, to perform these funrtions.

Page 29: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3COM* SUPERSTÁCK8 3 SWtTGH 4400 FAMILY DATA SHEET

RESILIENCY

MAWAGEMEMT

Remóte Managempnt

Support for 3Com Advanced Redundant Power Supply; provides backup power to the swítchBackup and restore of switch settings

SNMP vi, SNMP v2, SNMP v3 secura encrypted managementUser-selectable management VLAN

Software Backup and restoreTFTP configuration: upload/downtoadTFTP agent: upload

Configuration Command lineSerial (9-pin, D-type connector)TelnetWeb-basedSNMP

One-to-oHE

RMON (Remóte Monitoring) Fourgroups; statistics, history, alarm. andevents

IP Address Allocation DHCPBootPManualAuto IP

Network Time Simple Network Time Protocot (SNTP) for time stamp of events caplured vía Syslog

Management Software 3Com Network Supervisor (copy provided with product)• Topology discovery• Changa management reporting• Capadty planning• Evenl logging• Fault identification and troubleshooting• Utilizaron monitoring

OPTiONAL SERVICE AND SUPPORT

Network Health Check An activity-auditing sen/ice focused on improving network performance and productivity

tndudes traffic monitoring, utilization analysís, problem identification, and assel deployment recomrnendations

Extensive report provídes bluepjint for action

Nptwork (Jesign

Network Installíition

Projpct Managemenl

3Com GuardiarV"' Main ten anee Service

Includes review of business plan, extensive inventory of requirements, and complete design documentspecifying implementation details

Experts set up and configure equipment and intégrate technologies to maximize functionality andminimize business disruption

Service may include physica! site surveyand network design and engineering based on evaluation ofbusiness objectives

Provides extra focus and resources that special projects dernand

3Com engineer(s) manage entire process from initial specifications to post-project review

Using structured methodology, requirements are identified, projects planned, and progress ofjmplementation activittes tracked

Provides comprehensive onsite support. including advance hardware reptacemení, telephone technicalsupport, and software upgrades:

» Telephone support backed by powerful call-tracking datábase and replication laboratory

• Software upgrades ensure access to pertinent patches

Express""1' Maintenance Service Benefits customers who prefer to maintain awn hardware

Bolsters in-house resources with convenient and speedy access to 3Com hardware replacements,software upgrades, and telephone support

Page 30: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3CQM® SUPERSTACK* 3 SWITCH 4400 FAMILY DATA SHEET

SuperStack 3 Switch 440Qs as wiring closet aggregators,

with 3Com Switch 7700s as building aggregators.

3Com Switch SíJOOs m the core of an pnterprise network,

wííh 10G Ethernet links to satellrte buildingr..

Page 31: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3GOM* SUPERSTACK® 3 SWtTCH 4400 FAMILY DATA SHEET

3°*"

d——SupeiSlack 3 Switch 4400 PWR provides power and data tu

POF-rapable phones, and ddla tu PCs.

SuperStack 3 Swilch 4400, with lODEASE-LXl O connections to a

local service provider, próvidas converged services to tlients within

a 10km radius.

The SuperStack 3 Switch 4400 adds support

for the ernerging lEEt 802.3ah Ethernet in

Firsl Mile over Poinl to Point Fiber (EFMF)

standard. This enables the reach of Fast

Ethernet over fiber to be extended lo ai least

10km, giving a cost effective solution for wide

área Ethernet distribution. Support íor two

EFMF finks per swttch, or múltiple EFMF (inkí

aggregated across a stack of switches, enables

a resilient and scalable solution to be tmple-

mented. Combined with the Switch 44005

powerful QoS. Traffíc Shaping and Multicasting

features, the available uplink bandwidth can

be iritefiigently shared between users.

*««*

Page 32: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3COM* SUPERSTACK* 3 SWíTCH 4400 FAMILY DATA SHEET

Connectors24;" or 48 auto-negotiaüng 10BASE-TV100BASE-TXports cinifigured as Auto MDI/MDIX

24 auto-negoliatitig In-Linc Power 10BASO-T/IOOBASE-TX ports ronfigured as Auto MDI/MDIX|24-port PWR only)

24 I00BASE-I-X porls(24-port PXonly)

2 module sluts nccummodaling media modules orülaekm^ modules

All fibei ttmnectoi-s «lie MT-RJ [I_r i:unnei:tor onSuperStnck i Swilch 4400 ÍOOBASE-LX10 Module,X'17229)

Advsnccd Redundan! Power Sysicm Typc 2Aconncctor

Advunced Redundan! Puwcr System Type 3 cunnectur(24-port PWR only)

HS2Í2 ntTisiilr poi't

SecurityRADIUSfRFC 286%, RFC 2864)

Scssion acrtmnting (Ki;C 28*if>)

SSH v2(SSH Securc Sliell. TuTTY', OpcnSSH)

IEHIÍS02.1X nctwork login

StackingUp lo 384 10/IOO frtmt panel porls

Mix a lid match Switch 4400 24-port f .iC 17.103), 440»48-port (X'l 7204), 44OO PWR |lC1720r>}, and 4400 PX(iC17210)

Stack Switch 4400 SF.f ÍC17206] only w-ilhulher likc units''1

Performance24-parl8.8 Gbpsi Frirw.ii dinu haudwifl) li

ft.h inilliiin packets per seamd

8,000 MAC addicsscs supponcd

•18-pnrin.fi íibps forwarding bandwidth

10.1 millinn packcts per second

8,000 MAC .iildi-tNscs supporlcd

Refíabílity(MTBP '<>' 40'Cj

24-povt: 29 wars (254,0(Kl houi's)

24-port l'WK: ¿h yuais j'2i 1,00(1 hours]

24-port FX: 20 ycaií (228,000 hours)

•18-pi>rt: 20 years (179,0110 Inuns)

Dimensión sHeight: 43.6 ramf 1.7 in or 1U)

Widrii: 440 mm (17.3 in)

Depth:24 port PWR: 304 mm f 12.0 in)24-porl FX: 270 mm (10.6 in)all othere: 274 mm ¡10.8 in)

Weigín:24-port: 2.8 kg (6.2 Ib)24-port PWR: 4. S kg (10.1 Ib)24-portFX:2.7kg(6.t)lb)48-port: 3.2 kg (7. 1 Ib)

Envi ron mental RequirementsOpcraling temperature:00to400C(32°tolÜ4uF)

5wragí' '/i'ntpcralure:-40° to <-7lPC [-40* lo 4- 1 58CF)

Qpeniting Humidity:10°/u tu 90% relativo humidity noncondensing

Standards: Í5N6()0&8(lKC(i8)

Industry Standards SupportedlliüO 802.11) (STP)

IEEE 802. Ip(CoS)

IF.F.E802.1CJ (VLANs)

lKhH802.1X{Se(;urity)

1Í-F.I- B02.3ah f ÍO(MIBASE-T)

IHHH 802. 3ad (l.ink Ajígrcgatíon)

IEEE 802.3aJ' (Power oveí Ethernel)

IKl-.E 802. Jah (F.thcrnct in First Milc o ver Poilit tuPoint Fibcr - 1-FMI-)

IEEE 802. 3¡ (10BASF.-TJ

IEF.F 802.3u(Hast Mhcrnctj

I [-fifi 802. 3x(Fli>vv Control)

IF.HR 802.3^ (Gigabit í-thcrntt)

Safety Agency Certificatíons24-porl: ül.1950, ENStVI-iO, CSA22.2 No. 9'>0, il¡C60950

24-port PW1Í, 24-pon L'X. and 48-port: U!.hl'9r.O,i;N60950, CSA2.2 No. 609>0, 1]!C WIO'iO

Emissions[•N5S022 Class A. I-CC Parí 1 5 Subparl B Class A.ICES-003 Class A. VCCI Class A. AS/NZS 3548 Class A,CNS 3 M18 Class A

CISl'K 22 CI.ASS A, ENhlíHK)- I-?., HNI»UIOO-3-J (24-port PWK only)

Immiinity: ]-N">3024

l-ít'tii Dtssipation:24-port: 100 W máximum] 141 liTU/lir max'iiniitti)24-port PWR: .*.7'> W niaxiimini (938 BTL'/hr máximum}24-poit 1;X: I01! W máximum (3S8 B'IU/hr máximum)48-p(»i ' t - 12O W máximum (410 BTU/hr máximum)

Power SupplyAC Line Hrequency 50/60 H^

Input Voltage W-240 VAC

Current Ratiti^:24-port: 2.3A máximum48-port: 2.8A máximum

SNMP StandardsSNMP Prolocol (RFC 1157)

MIB-llfRFC 1213)

EridgcMIBfRFC 14*) 3)

R M O N M T B I I (RFC 2021)

Remott; Moiiitoring MIÉ (RFC 1737)

Intcrfacc M I B f R F C 2233)

Remóte Poli MIR (RFC 2«Í2'>)

MAU MiI((RI;C2668)

SNTP (RFC 2030)

PoE MIH (RFC 484) (24-ptirt PWK only)

ManagementWeb intcrfacc

Command lint? iiitrrfhci-

SNMP cumpatibiüty

Managcmcnt thiough 3Com inaniígemcnt .ipjititntioii!,

- 3Cum Nclwork Supci-visor

- iCom NeLwork Director

- iCom Nctwork Administrator

- 3Cnm hnlurpiiM: Maiiíi^fiDL-nt Suilc

WarrantyIJmited Lifetime Hardwatt- Warranly. LimitedSoftware Warrdnty for nim'ly (901 days. Scc\vww.3i:i)tn.(:i>iti/wdrranty fitr di'iailü.

Other BenefitsOlher Service Bcnelils: Adv.iin:e hardware re pía cernen twith sauíf day shipmrnl fui North America andWesttTii Europv. IVtxl day shipmcnl fbr icst of woild.Calis musí be rcccivcd by piihlished fut-off times.OOdays o["tc-|i.'phfHic toclinical ^upport. Limited softwarei ipd.it c .Si'c www.3cttm.unn/warranty for morr dciatl.Itt'^isler producís at htlp://eSupport.3fom.com.

ServiceAmeri cas:www.3cuni.com/producls/cn_US/globaLservices

International:http://cnica.icom.com/glohalseivkt.-s

(1) 24-port spcxifications rufer tu Swlch 4400 ¿4-Port (3C17203), Switch 4400 ?.4-Port PWR (3C 17205), Switch 4400 24-Port FX (3C i 7210), and Swilch 4400 SE 24-"urt

(3C 17206), unleís otherwise noted.

(2> Wlth installation of optional SupsrStack 3 Swiích 4400 Enhanred Software Upgrade, 3C1 7207, the Switch 4400 SE will stack with the Swrích 44ÜÜ ¿4-porl, 4400 4S*port,/_^00 PWR, and 4400 FX.

Page 33: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3COM* SUPERSTACK* 3 SWITCH 4400 FAMILY DATA SHEET

PRODUCTDESCRfPTION

3Com SuperStack 3 Switch 4400 24-port

3COPVJ SKU

3C17203

3Com SuperStack 3 Switch 4400 48-port 3C17204

3Com SuperStack 3 Switch 4400 PWR 3C17205

3Corn SuperStack 3 Switch 4400 SE 24-port 3C17206

3C17210

Optional Modules and Accesiones

3C17207

3Com SuperStack 3 Switch 4400 1000BASE-T Module 3C17220

3Com SuperStack 3 Switch 4400 1QOOBASE-SX Module 3C17221

3Com SuperStack 3 Switch 4400 100BASE-FX Module 3C17222

3Com SuperStack 3 Switch 4400 1000BASE-LX Module 3C17223

3Com SuperStack 3 Switch 4400 100BASE-LX1Q Module' 3C17229

3Com SuperStack 3 Switch 4400 Stacking Kit 3C17227(Two stacking modules and cable to stack two Switch 4400s—see stacking specificationsabove for restrictions)

3Com SuperStack 3 Switch 4400 Síack Extender Kit 3C17228(One stacking module, one cascade module and one cable for adding more Switch 44DOsto an existíng Switch 4400 stack—see stacking spec/'fícafíons above for restrictions)

3Com SuperStack 3 Advanced Redundan! Power System

3Com SuperStack 3 Advanced RPS Type 3 module

Express1" Service Plans* American

3Com SuperStack 3 Switch 4400 24-port 3CS-FXP-05E

3Com SuperSíack 3 Switch 4400 48-port 3CS-EXP-08E

3Com SuperStack 3 Switch 4400 PWR 3CS-EXP-06E

3Com SuperStack 3 Switch 4400 FX 3CS-EXP-09E

3Com SuperStack 3 Switch 4400 SE 3CS-EXP-03E

3C16071B

3C16074A

3C16075

EMEA/AP'3CS-EXP-X30S

3CS-EXP-X309

3CS-EXP-X307

3CS-EXP-X310

3CS-EXP-X303

* Switch *1400 software versión 5.1, mínimum, requirpd for operation.t inrludeí telephone support, advance hardware replacpment, and software upgrades.t Europe, Middle East, África and Asia Paciiic.

Page 34: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

PRODUCT DETAILS

3Com® SuperStack® 3 Firewall

Product#: 3CR16110-95-US

DISCONTINUED

End of Sale Staternent

Product Speciñcations

• Interfaces: Three RJ-45 10/100BASE-T Ethernet/Fast Ethernet(WAN, LAN, and DMZ) portswith auto-negotiated speed anddúplex mode; all ports areUplink/Normal selectable• Performance: Unlimited 190Mbps firewail throughput forusers; 30,000 concurrentTCP/UDP sessions; 1,000concurrent branch VPN tunnels;encryption throughput up to 45Mbps VPN DES and 3DES, 21Mbps VPN ARC4• System: Dedicated real-timeoperating system; 233 MHzStrongARM RISC CPU; VPNcrypto accelerator co-processor;real time clock with lithium-ionbattery; 16 MB RAM; 4 MB FlashROM• Power: Input voltage: 90-264VAC; 47-63 Hz operatingfrequency; 3Com AdvancedRedundant power supplyconnector Type 1• Protocols supported: TCP/IP,UDP, ICMP, DHCP, NAT,PPPoE, HTTP, RADIUS,SecureID, ARP, MD5,IKE/ISAKMP, IEEE 802.3, ISO8802-3; IPSec ARC4, DES, 3DES• Management: Embedded WebGUI interface (plain text orHTTP/SSL encryption); 3ComNetwork Supervisor support;

Package Contents• Firewall• Rack mounting kit• Power cord (48cm/19 in)• Rubber feet• CD with uniimited IRÉ SafeNet-PKVPN Client (¡cense for Windows• WebTrends evaluation softwareCD• User'sguide

Please Note• SuperStack 3 Firewall ships with56-bit encryption; 168-bit availablewherever import/export laws allow.Information on global restrictions canbe viewed athttp://www,3com.com/firewaH qlobaí/.

Page 35: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

event Logging via e-mail, SNMPv 1, Syslog server; website, client,and category filtering; automatedfirmware update notifícation;WebTrends Firewall Suitecompatibility; N2H2 andWebsense Enterprise contentfiltering compatibility• Height:IRU,44mrn(1.7in)• Width:440mm(17.3in)• Depth: 230 mm (9.0 in)• Weight:2.55kg(5.61b)

System Requirements

• IRÉ SafeNet-PK VPN clients:Windows 2000/98/95/NT 4.0

Page 36: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3CorrT OfficeConnecf Wireiess 54 Mbps11g Print Server

• WPA security helps ensure theprint serven strengthens yournetwork security chain

• Liberates a PC acting as a printserver to do more useful work

• Wireiess connectivity eliminatesthe cost of network cabling,and gives you the ílexibility toset up a printer ¡ri a convenientlocation

Flexible High-Speed ConnectivityWith this compact print server, you cantxonomically exlend the accessibility ofyour prinlcr, sharing it among wirelessand wired network users no matlcr wherethey are located. The print server connectsa USIl 2.0 printer díreclly lo the networkthruugh either a 54 Mbps lEEtí 802.1 Igwireless or 10/100 Hiberne! conneLÜun.The USB 2.0 port Jiandles the la test high-speed data transfer rales for íasterthrnughput of even large multimedia filesand is compatible with USB 1.1/1.0 primers,

Strong WPA SecurityYou can't havc a secure network wilhout asecure print server. The 3Com*OfficcCotmcctl; Wireless !>4 Mbps 1 Ig PrintServer oflcrs advanced Wi-Fi ProtectcdAccess (WPA) as wcll as basic WiredRijuivalcnt Privacy (WEP) encryption toefFectively proteci your wireless network.

Multi-User, Standards SupportIEEE 802.1 Ig preserves Ub invcstmentswhile supporting highcr speed tuchnolo-gies. The wireless print server alsosuppoils múltiple wirtrd and wireless PCand nutehuok nsers running a variety <ifpopular operating syslems Windows,Macintosh, Unix, and Linux.

Simple InstallationA familiar Web browser interíace andhelpful sotup wizard mnke ¡nstallation andconfiguration easy.

FLEXIBLE HÍGH-5PEED CONNECTIVÍTY

Description

Aíircd and wireless useí support Shares a printer among wired and wireless users.

Múltiple OS support Interoperates with a variety of popular operating systems, such as Windows, Macintosh, Unix, and Linux, toaccommodate many types of users.

JSB 2.0 port Handles íhe latest high-speed data rates; compatible with USB 1.1/1.0 printers.

EEE 802.1 lg standard íupport Supports 54 Mbps technology; backward compatible with the 11b standard, protecting 11 Mbps investments.

Vireless network connection Avoids cabling effort and cost5 and enables you to set up a printer in a convenient office bcation.

SIMPLE ¡NSTALLATION & FLEXIBLE OPERATION

Veb browser ¡nterface, setup wizard Make installation and configuration an easy task, even for novice users.

wo operatíon modes Choose infrasíructure mode for expanded connectivity through an access poiní or ad hoc modp for simple,two-way, point-to-point connections.

SECÜRS USEVPA and WFP enrryptíon Advanced WPA encryption and WEP encryption help protect all Communications over the WLAN.

Page 37: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

The print server functions as a wireíess client, allowing wireless LAN users toshare a printer. Print job data flows from the wireless clients through the wiretessgateway/access point to the print server.

Wired LAN users can also share the networked printer through the wireíessaccess point and print server. Print job data flows from the wired clients throughthe wireless gateway/access point to the print server.

Page 38: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3COM* OFFfCECONNECT" WIRELESS 54MBP5 116 PRINT SERVER DATA SHEET

Mínimum System RequirementsOperating System that supports an Ethernet connectionwith an IP stack. Installation CD requires WindowsXP/Me/2000/98/95/NT 4.Ü.

Computen; with an Ethernet IOBASF-T tir 10/100mterfacc configurcd for I.AN commu ni catión orwirclcss U-l-C 302. 1 1 b/g PC Cards ur USB adapten;for WI AN communicaticin.

Prínter CompatibilityThe 3Com tjffíccConnec't Wireless 54 Mbps I Ig PnntServer supports many USB printers, iiicfuding thosefrom HP. fipson. Lexmark, Ciium, and othcrs. Picaseclicck with ywur primer itianufacturtT lu see if yourprinter tan he used wit l i a print servar. Multífunction(print. sean, fax) printers are oiily supportcd inprinter mocle.

Note: The fbHuwiiig printc-rs are uot compatible wiíJ tiht print ser ver

• Hosl-based ur GDI (Graphit Disptay Inlurfact-)pnnteis, lurexamplc:

- HP 700c, 820c, lOOOc, Í300c and 3400c series ofPPA príiitcr?;

HP Di-skjcl 820cxi, IIP I,ascr,Ici 1000 and HPI.ascr.Ict 3 100 series

• The foHowiug CAPT (Cüiioit AdvaiRTd PrinliiigTeihnolugy) printcrs:

LBP-250

LBP-810

i.üp-nio- l.BP-1120

- I.BP-12JÍI

- I..BP-2410

• Tliü fiillowiuji !)«)] MFP printcrs:

A9-10

A%ü

.1740

• Thf foi)owiiij> Kpsnn Inwr printcrs:

U'l.MK)

KPL 5800

HPL2050+

Interfacestitfntrnet: RJ-45, 10BASE T/lüUBASE-TX

WLAN: 802.11g/b Wi-Fi compljant

Prmitr: USB 2.0 (3.1/1 .0 compatible)

Wireless Data Rales802. Ug: 54. -18, 35. 24, 18, 12, 9 aiid 6 Mbps

802.1 Ib: 1 1, 5.5, 2 and 1 Mbps

Frequency Bandg: 2-4-2.4835 GH/.

• Lexmark Prinlct X'il ' ítí (MFP)

• The fnll t íwing MinoKi) láser pniiters:

PagePru Ci^OW

- Paj?,ePro 12SOW

• MagJaJot 2.ÍOOVV

Transmit Range¡Ig (5 -i Mbps): 3Om(9(>íl) obstructcd, máximum;60m (197 ftj unohslrutted, máximum

llb(ll Mhps): 50m(164 ft) obstructed, máximum;150m (492 ft) unobstructed, máximum

Ante n na2dBi ncm-removabíe antcnna

Transmit Power18.89dBm

Receiver Sensitivrty1 Mbps: -93 dBm

2 Mbps: -92 dBm

5. 5 Mbps: -92 dBm

11 Mbps: -83dl?m

12 Mbps: -RJdBm

24 Mbps: -82 dBm

ift Mbps: -77 dBm

48 Mbps: -74 dBm

•í4 Mbps: -74 dllm

ChannelsCliannel availabilily depcnds 011 local regu),ilions,

Channels 1-lJ (United Stales, Canadn, México.Coluinbia. Taiwati|

Chamirls 1 -1 3 (rcst of world)

IP Protocol SetTCP/IP, NtitlitiUl, AppleTalk

Operating SystemsWindows 95/(j8/2(HK}/NT/Me/XR Macinlnsli OS 9.Xand lííght-r, Unix

Prínting Methods:PTP (Píer-to-Peer) i»verTU'/lP or NetBEUI, U'Hpriiiliiií;. SMBpr tn i i r ig wver TCP/IP oí NeiBEUI, IPP(Internet Prinling Pmloa>l), AppleTalk (KthciTalk)

SecurHyWPA, -10 /64-/128-bit Wt;P shared key eiKiyptnm,rtp(;n-/shnred-key wireless auihenticatinn

DimensionsHeight: 2.5 cm (I ÍTI|

Length: «J.5 cm(3.7 in)

Wu/í/ j .6. icm(2.5in)

Standards CortformanceIEEE 802.llg, IHFF 802,1 Ib, IEEE8O2.3, HTTP,WPA, WEP

Power Supply:5VDC. 2 Amp

Regutatory/Agency Approvals¿"AfCFCC Pan 15 Subpart O; 15.217, 15.207CK

EN301 489-1/-17 (EN'i'i022 and EN55024)EN 300 328 -1/-2C-TickCanadá ICES-003, RSS210

UL60950R&TTE Arlfi.4Taiwan DGT

Configuration and Managementbmbeddcd HTTP Web management, sctup wi/ard

LED IndicatorsLirror, Status

Environmental Operating RangesOpct'aling TtTnpet ature: £1 lo 40°C (32 to 104°F)

Sloragc Tempei-ature: -10 lu 60°C (14 to MQT-'J

Package Contents3Com OtlUX'ConiieL'l WirtJess 'i4Mbps 11^ Print Serveí

Power supply

Quick Star! guidc

CD-KOM with user guíde and configur.itinii software

Wnrranly shcet

Warranty SummaryThrec (3) Year hardware warranf y. Refcr towww.3com.com/warranty fnr details.

Page 39: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3COM8 GFFICECQNNECT94 WIRELESS 54MBPS 11G PRÍNT SERVER DATA SHEET

PRODUCT DESCRIPTÍON

3Com OfficeCgnnect Wireless 54Mbps 11g Print Server

Related producís

3Com OfficeConnert Wireless 11a/b/g Access Point

3Com OfficeConnect Wireiess 11g Access Point

3Com OfficeConnect Wireless I1a/b/g PC Card

3Corn OfficeConnect Wireless 11gPC Card

BCorir^OfficeConnect ADSL Wireless 11g Firev;aíl Router

3Com OfficeConnect Wireless 11g Cabie/DSL Router

3COM SKU

3CRWP510075

3CRWE454A72

3CRV\'E454G72

3CRWE254G72

3CRWE154A72

3CRWE154G72

3CRWE754G72-B

3CRWE554G72T

3Com OfficeConnect Wireless 11g Cable/DSL Router 3CWE

Wireless producís not avatlable m all countnes - please rherk with your local reseile' or 3C.cm office fur lot.nl dvaiidb lily

scom

Page 40: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3COM* 11G 54MBPS WIRELESS LAN BUILDÍNG-TO-BUÍLDING BRIDGE FAMÍLY DATA SHEET

MÚLTIPLE SECURITY FEATURE5

Wi-Fi Protected Access-Pre-Shared Key (WPA-PSK),Wired Equivalent Privacy fWEP), and AdvancedEncryption Standard (A£S) encrypljon

Description

Múltiple encryption and authenticatión sehemes protect all Communications over the wireless LAN.

VPN and VLAN pass-through Créate secure tunnels for remote site-to-site or site-to-user data exchange.

Weatherproof, fire-resistant enclosure withintegrated antenna (Outdoor B u ild i ng-to-BuildingBridge i

Rugged enclosure meets stringent outdoor environmental. safety, and security specificatíons; 18dBipanel antenna maintains a consistently strong directional signal.EC/EN 60529 IPX4 rated for water íngress protection meets the UL 50 and CAN/CSA C22.2 No.94, type 3Rrating.

INSTALLATION AND MANAGEMENT CONVENIENCE

Point-to-point and poinl-to-rnultipoint topologysupport

Provides máximum flexibility in configuring building-to-building networks; point-to-multipoint configurationsupports up to seven bridge connections with either indoor or outdoor bridges.

PoE íupport Power can be supplied by the incíuded power injectoror by a compatible Power-over-Ethernet (PoE) switchfor deployment flexibility in hard-to-wire or remote locations.

Web browser, 3ND, and SNMP support Enable administra tors to remotely rnanage the bridges from anywhere and seamíessiy intégrate LANs withenterprise management tools.

Nürt: 16.9 km (10 mi) range requires 3Com wireless LAN building--to-building bridges on both buildings. Dará throughput can vary depending on several factors, includingnetwork traffic load, distance b0tweí>n bridges, antennas, line-of-stght, and local and remote fMI and Freznel zone obstructions.

Bridge Point-to-Point Configuration

The 3Com wirele^s LANindoor and outdoorhuilding-tobuiltiing

bridqes can bp dpployed

alone or in combinalion,

in poínt-lo-point or

point-to-multipointconfiyuratiorib, to ineet

diffeffint distance and

coverage needs.

for example, on a school

rampLis, the outdoor

builciing-To-building

bndqe can he installed ona matn office building,prcwidtng nctwork arces:for adjact?nt clasoroom

huildings or portables

instclled with 3Com w¡r»>-

It'S'i inrioui ¡>r ui.tdtioi

buildiny-iu-builuinybridges.

Supports distances up to 10 mtles{17 km)

Bridge Point-to-Multipoínt Configuration

Adjacent classroom buildings installed with 3Com 11g 54MbpsWireless LAN Indoor Building to Building Bridges or 3Com 1 lg 54Mbps

Wireless LAN Outdoor Building to Building Bridges

Page 41: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

3GGM* 116 54MBPS WtRELESS LAN BUILDING-TO-BUHD1NG BRIDGE FAMtLY DATA SHEET

InterfacesR.I-4-Í, 10BASF-T/100BASK-TX

802,Jlb/g

Wireless Data RalesS02.llg: 54, 48, 35, 24, 18, 12, 9 & 6 Mbps802. ¡Ib: 11, r>.5, 2 & 1 Mbps

Frequency Band

Wireless Transmit PowerOutiinar Buittling tu Builtiiug Bridge:17 dBm: +/- 1 dB(US, Canadá, México]

20 dBm +/- 1 dBJRurope, UK, Irekmd, Ldtin America)

Ijjdanr tiuitding-tfl Bnilding Bridgc:17 dBm (US, Canadá, México)

20 dBm KIKP raax. dependí ng on antemia and cableconfiguran o u (Europe, UK, Ircland, Laün America)

Network Architecture TypeBridgr 802.il» 802.1 Ib/y

Number of Users/Brídge

Up tu 1000 ustrs

Wireless Bridges/LAN

Urilimited

Modulation Tech ñique1>SSS (f)irrri Sc^uenrc Sprcad Spcrtrum}

QFDM (Orthiígonal Fi'tqucncy Uivision Mulüplcxinj»)

Media Access ProtcxolCSMA/CA

Receive SensitivityR02.ll$34 Mbps: -70 dBm

48Mbps: -72 d Jim

IGMbfis : 7-1 dBm

24 Mbps: -77 dBm

18 Mbps: -79 dBm

12 Mbps: -Rl dBm

ffMbps:-8i dRm

C. Mbps: -8"i dBm

802. ¡Ib-

1 1 Mbps: -BGdBm

^.5 Mbps: -SRdlim

2 Mbps: -8ÍJ dBm

1 Mbps:-Ql dBm

Standards Conformancel í : l i l :8(U. l )b . SOJl .Hg. 802. .i, and 802. I X ; IITTi;VVPA, wi;i'

AntennaOuidfwr fiuilciing t» fluildirtg lírid*fc: Intc-graU'd 1 SdlfidircLTtional panel aiiU'niia (ly*1 beam atiple)Ituionr Ruilding- to líuitfting nridga: AtiUnuia must lu:ordorcd at the time i>f bridjli: purrhase. Sct; OrderitigJiifiirnwtiíin ii>i -intcima nnd cable opiimis.

Security64/128 -bit Wi-H 1 ¿S-bit AIK, WPA TKIP fmryption;WPA-PSK antheiiticatioH

l.otal MAC address íiltcnng

VPN and VLAN pass-ilirough

Networking ProtocolsNetRui, IPX, TCP/IR Hiidx¡njí Prt>l«n.o!, Spanniny Trec

Prutocol, SNMP, RMON, PHCP

ManagementCommand linc intcrface (via Tclnet or SSH]

HTTP LH S -HTTP Web bruwser interfate

SNMP

3ND

Kemnlp soflwnre upgrades vid HTTP

LEDsPnwcr, l.AN .irlivity. Kadiíi aftivity

Physical DimensionsJnctoar Butlítíng-ta-Builfiing liridgi'I.en^th: 6.9 i)i (17 "i cm)

W i d l h ; 4 . 7 & i n ( 1 2 . l rm)

Heighl: 1.4 in (3.6 an)

Wcight: 0.575 Ib (O.Ib kg)

Outdoor Ruilding-1 a fíiiüdinif BrüÍf¡c:

Length: 15 in(38cm)

Widtli: 13.78 in( .J5cm]

Heiglil: 2.71 ni (7 cm}

Wcight; S .6]b(2 . r>4 kg)

Regulatory/Agency ApprovalsSafety:

UN 60950 2000, IEC 60950 I:ditioii 3, CSA 22.2 609503rd edition, UI, 60lJWt Jrd edítion, til, 204J, 1L;C60529. NOM-109 SC1:1, AS/NZ J2hO

Radlo/Eluct romagncí fe:47CFRPart 15, Scction Ir».247, 15.207, 1Ü,407:FCCOJ-287 I'ails 2 & 15, Fcc lltilletin OHC-h1»; Canadá KSS-

102 Jssues 1 & S; EN ÍOO-)28, liN J01 983, I-N .501-181)

Htrtissiottvjltnmunity:ICHS-003 Class B, KX Parí 15 Class B, J-TS1 1;N 301

489-17. EN 55022:19«M+A1: 1995-Í-A2: 1W7 CLiss A,EN 61000-J-2:20íM), IÍN hHKXM-J:1995+Al:2(K)l

Environmental Operating RangesOperatíng i t-m peni ture: -3 i to r>0°C (-27 to 122 *!•)Storagc tt'iiipL-raiun': -2t) lo 70eC (-Í tu 158 T]Altitud?; Up lo 3 km (1 ,R6 miles)Hunñdtíy: '> U> 9"i% nnu-condcmiugWimi (Outdwr Hridge): Opcr3lion.il load ing iip t i »15:J kmpti f 'Jj niplí}; wind surviv.il lo 201 kniphÍ125 mplí)

Package Contentejl Mbps 1 Ig Wireless l.AN Indoor or OuidooiBuildiitg ti> liuildinji Biidgc

Powci (idapler/Poí: injcclor

PovvL-i t-ab!u fur Fcd; hijfclur

IJglUniíig arrestor (Outdooi B-lo-B biidgr)

Mouiitint; br.irkrt

CD-ROM vvíth iiSE:r guitk- and cunnguraliotí MifU%ti[L'

Wa iraní y boiiklcl

WarrantyOnc-yfar limitcd w,in'antyRelor i t í www.3com.com tor deíaüs

Page 42: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

D-Link Australia & New Zealand - DES-1008D Página 1 de 2

D-LínkB u i l d i n g Netv/ork', for Pcopíe

DES-1008D

8-Port Desktop Switch

Easily créate a high-speed Ethernetnetwork.

PRODUCT FEATURES

• 8 x 10/100Mbps Auto-sensing on All Ports• up to 200Mbps per Port• All ports support half/full-duplex• Compact palm-sized

PRODUCT DESCRIPTIONS

The D-Link DES-1008D is a Dual-Speed 8-port 10/100Mb Ethernet/FastEthernet NWay auto-negotiating Switch. It is designed to elimínateunnecessary traffic, and relieve congestión by delivering dedicatedbandwidth for each of the eight ports.

The DES-1008D can be deployed with múltiple high-speed servers forshared bandwidth to lOMbps or lOOMbps workgroups. With the highestbandwidth at 200Mbps (lOOMbps in full-duplex mode), any port canprovide workstations with a congestion-free data pipe for simultaneousaccess of the server.

The DES-1008D compiles with IEEE 802.3 10BASE-T and 802.3u 100BASE-TX, which specify NWay auto-negotiation, Flow control in half-duplexmode.

The DES-1008D combines dynamic memory allocation with store-andforward switching to ensure that the buffer is effectively allocated for eachport, while controlling the data flow between the transmit and receivenodes to guarantee against all possible packet loss.

The DES-1008D includes added brackets, maximizing space whileincreasing port density.

Features

(8) 10/100Mbps R3-45 PortsAuto-Senses Cable Type (Auto-MDIX)Half/Full Dúplex SupportAuto-NegotiationWire-Speed Reception and Transmission2K MAC Look-UpBroadcast Storm ProtectionBack Pressure Flow Control for Half-DupiexAutomatic MAC Address LearningSwitching Method: Store-and-Forward

Page 43: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

D-Link Australia & New Zealand - DES-Í008D Página 2 de 2

• RAM Buffer: 128Kbytes• Protocol: CSMA/CD• Compiles with: 802.3 lOBase-T, 802.3u lOOBase-TX, 802.3x FlowControl• Certiflcations: FCC Class B, VCCI Class A, CE Mark• LED's: Power, Colusión, Link/Act (5)• Dimensions: 19.2cm x ll.Scm x 3.2cm• Weight: SOlgms• AC Input: 7.5V/1A , 3.6Watts (max)• Operating Temperatura: 0°C to 50°C• Storage Temperature: -10°C to 70°C• Humidity: 10%-90% RH, non-condensing

D-Link Australia Pty. Ltd. Tel: +61 (02) 8899 1800 Fax: +61 (02) 8899 1868Address: 1 Giffnock Avenue North Ryde NSW 2113

D-Link is a registered trademark of D-Link Corporation. Specifícations are subject to change withoutprior notice. AH other company or product ñames mentloned herein are tradernarks or registered

trademarks of their respective companies.

Terms of Use | Privacy Poíicy

© 2006 D-Link Australia. All rights reserved. *

Page 44: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

D-Link Canadá - DES-1024D - 24-port 10/100Mbps Fast Ethernet Switch Página 1 de 1

D-Línk Select Product Product Quick Find:. r r w a

EtherNetworlc

24-port 10/100Mbps Fast Ethernet Switch

DES-1024D

Features Resources

Non-Blocking Wire-SpeedArchitecture4.8Gbps Switching CapacityUp to 200Mbps per PortTrue Plug-and-Play (Auto-Sensing,Detection, and Configuration)Supports Industry StandardsIncludes Rackmount mountingbrackets

Product Description

Product JmagesFront ViewWarranty

The 24-port D-Unk DES-1024D unmanaged switch is the latest addition to D-ünk'spopular line of Express EtherNetwork™ producís. Like other producís in the line, theDES-1024D combines ease of use with unsurpassed performance resulting in anexceptional valué for any cost-conscious network administrator who wants the bestpossible solution at the best possible pnce.

The DES-1024D is truly Plug-and-Play with features fike: Auto Speed Sensing - allowingit to automatically sense whether a network device is running at 10Mbps or lOOMbpsthen automatically adjusting itself for optimal performance; Auto-Negotiation (Full or HatfDúplex) - negotiating and running the highest supported transmission rate whether atHalf- or Full-Duplex; and Auto MDI/MDIX Crossover - offering auto-negotiating MDI/MDIXdetection on every port to elimínate the need for crossover cables or uplink ports.

The DES-1024D features a non-blocking wire-speed architecture with a 4.8Gbpsswitching capacity, for máximum data throughput. It also features an integrated universalpower supply, and per port diagnostics LEDs that make it easy to "spot check" forproblems. With wire-speed filtering and Store-and-Forward switching, the DES-1024Dalso maximizes network performance while minimizing the propagation of bad networkpackets.

Technícal Support | D-LinkShop Online Store j Ünk MagazineCopyright © 2005-2006 D-Link Canadá, Inc. All rights reserved.

Page 45: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Micro-Switch/88 Port 10/100 Base-TX Fast Ethernet Switch

* JMMHt JrcMtf MMM

UNÍ

PeafeurosaPerfect for Home/Small Office

• Conforrns to EEE 3ÜZ3.8Ü13u. and 8CG3x standares

• 8 N .ay IÜ/IQOTX Ethernet RJ-45 porte

• Automatic MDLMDÍX Crossowr* for lOBase-T &lOQBase-TX porte

• Back pnessure for Half-duptec, Row controlfor Fdl-duplex

• Store-and-forward swttchinj aithitectun;

• Non-btockingand Fullvrtrc ^jeídforwardingrate

• 5l2KDRAMframebufler

• 2K-entry MAC addness table

• LED-indicatars for Pnwi; LNKMCT FD/COL

• Durable metal case

8 P«t 10/10064M-TX Fast EtJwnwt Sateh

PART NUIWER DESCWPTIQN

FEP-32008T-1 Compact 8-Port 1Q/100Base-TX Fast Ethernet Switch

; nicom'-í Miao-Switch/8 is d compací 8 Port Ift'lOO FastEthernrt Switch designed for situll work groups. Thb

switeh pfovides eíght N-Way "lUf'lOOMbps RJ-45 porh with anAuto MDt-MtSX Crossoveí function and will automaticallydrtecl the specd oí the de\iceThaiyouplug into ít alfowingyoulo use lx>th lOMbps and lOOMbps.

The Micfo-Sw¡tcW8 has a dedicaied iCl/IOOMbps bandwickh.The liill-duplex operation mode eífectively doubtes IhebancKvidth foi each pan. K can increase the bandwidtfi of tlie]QM Ethernet jjort and the lOOMbps Fasl Bhemet |x«t to20Mbps aiid 200Mbps> respettively. Tu enlwiice the pütkettransmisión, this switcfi supports IEEE 602.3 full-duplex flowcontrol aitd halt-duplcx b.ick prassui e congestión control. Inadtfitiíjn. Ule .M¡ao-SwitcKf8 exocules Ihe method of store-and-tbrwarxl byr auto-leamtng and stores source addresses on a 2K-enlry MAC address taWe.

• Most hub& and iwitdtes JT« designed \uth one upInJs port t>catcode oth-=r hubs or $witche&. The MicroSwilchí'8 íupportsnew MDI/MDIX tedwolcgy - *ach pal nvn b* ertti» a ncrmalportea jn upJinkpoitoítiínngiJii autonwticcnítfovef tuncUonto•etttier loBgs^T cr lOOBase-TX ¡ilkwir you ro use «ttha-a pin-to-pin e* ci ?i.v»v« cable with no p^c-blams-

SPCeinCATIOMS

Starulanf ConipIMrKe:

SwtCdltlg Method:Fatturding Rite;Bulíw Mennry;

Ca«c Dhtanco:

UDIndkaiorK

Power Supply:Ehd<Kim>:EMI:

IEEE 802.1 1C8ASE-T Ed^n^IEEE 602Ju 100BASE-TX fot lú*maA NStl EEf standard 8O2. í N-lVay Arto

Eight i,6)R|-45 Ucfcswi* AuteMCH'MDIX

1 4,e80fps te* I OMbps: t •U.SOOppt tor (OOMbpts 1 2KB DRAM

2K-Entiy

lOOm Mw, wilh Cakgoy 3, 4. 5, 5e UTPícr 1 09as*-TlOOm Mw, wiít Categoy S, 5e, 6 LITPfcr loOfos^TX

Li»k'Arb/¡ty FHt

6,5" ili * 3,93" íWfI65mm x IQCnra v 25mm

txtenwl püww «bpter 5V DC ' TOOmft\taalFCC p«i 1 5 ctea \E Mjifc

UL, cU

v.-rt-w utiiciinitink com

90B Cjiud<i Con I. CA 9174S U.SA

^6*8 Rrt; Í26.964 7S60e-m,iit: ínfoCfumcomlinlc ccm

¡ftil •.KKOlffirfln+tKtijV'UtTIMf.bticlt. Kr'fl^fr^ti

SpKiftCtittons suiyect la dían¿v wiifaiü notire.

Page 46: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

IStur[ideaPten

[Two

1ülíí(lAcce;JPoíntPoint

llghFIEEE iUptoSuppc

(forGn

usletJWEPWPA-

JWPA-802.1xAESMAC Ai

[802.11J

fonvenlSupport

[ Ethernel[ Locking

lasyMaAPManaWeb Bro<Telnet

EQUIPOS NUEVOSPARA LA RED

DISEÑADA

rocliii

Page 47: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

DWL-3200AP

Managed Access Point H

lecificationslandardsIEEE 802.1 1b • IEEE 802.3 • IEEE802.3xIEEE 802.1 1g • IEEE 802.3u

evice ManagementWeb-Based - Internet Explorer v6 or later; Netscape Navigator v7or laíer; or other Java-enabled browsers.TelnetAP ManagerSNMPvS

Transmlt Output PowerFor 802.1 1b:* 158mW(22dBm)• 20mW(13dBm)

For 802.1 1o:• 126mW(21dBm)• 20mW(12dBm)

Receiver Sensitívitv

79mW(19dBm)• 1mw(OdBm)

•63mW(18dBm)•1mW(OdBm)

• 40mW(16dBm)

• 30mW(15dBm)

ata Rate2>r 802.11g:108, 54,48, 36,24.18,12, 9 and 6Mbpsir802.11b:11,5.5,2,and1Mbps

;curltyWPA - EnterpriseWPA - Personal64-, 128-,152-bitWEPMAC Address Access Control List802.11 i-Ready

Ireless Frequency Range2.4GHzto2.4835GHz

Ireless Operating Range3

12.11 g (Full Power with 5dBi gain diversity dipole antenna)doors:

•197ft(60m)@18Mbps•213ft(65m)@12Mbps• 256tt (78m) @ 9Mbps• 308ft (94m) @ BMbps

98ft(30m)@54Mbps112ft(34m)@48Mbps118ft(36m)@36Mbps151fl(46m)@24Mbpsitdoors:279ft(85m)@54Mbps656ít(200m}@18Mbps

1148ft(350m)@6Mbps

lerating Voltage!8VDC+MO%forPoE

idio and Modulation Typer802.11b:ÍSS:3BPSK@1Mbps[)QPSK@2Mbpsr 802.11g:rDM:3PSK@6and9IWbps3PSK@12and18Mbps¡SS:)BPSK@1MbpSDQPSK@2Mbps

[email protected]

'16QAM@24and36Mbps'64QAM@48and54Mbps

[email protected]

For 802.11b:• 1 Mbps: -92dBm • 5-SMbps: -88dBm• 2Mbps: -90dBm » 11 Mbps: -85dBmFor 802.11g;• 1Mbps: -92dBm • 9Mbps: -86dBm• 2Mbps: -90dBm • 11 Mbps: -85dBm• S.SMbps: -88dBm • 12Mbps: -85dBm• BMbps: -88dBm * 18Mbps: -83dBm

LEDs• Power• LAN• 802.11b/g

Temperature• Operating: 32nF to 104°F (0QC to 40°C)• Storing: -40°F to 149°F (-40°C to 65°C)

Humidlty• Operaíing: 10%~90% (non-condensing)• Storing: 5%~95% (non-condensing)

Certlflcatlons•FCC• Wi-Fi

Dlmensions• L = 10.93 inches (277.7mm)• \N- 6.10 inches (155mm)• H = 1.77 inches (45mm)

Warranty• 1 Year

24Mbps: -80dBm36Mbps: -76dBm48Mbps: -72dBm54Mbps: -72dBm

iiúmum wlteless signul ralBhaspdnn (EFE SwrdaitíB02.n<] speeifiealiQns Arfualctató íiroughput wül vaiy. Netwcxktxfticms arxJ oiyinxnentd faqlois. IncJoding vuluriie of r twaiK Iraltfc buídni) treilerials and corEttucUor. «xl nptwnrkerhewl lowcr actual Osla throughput ralo.aMmumvineless signal nos detived from IEEE Standard 802.11g spedUcaíais. Actual dala Hiroug|iputwinvaryNHW,w1'r.üffiaiis aod cnviFcnmGntal feíclOR. hdiicliog voUne dnílwoili imite, build ng materias aiwt «nynjctkxi, aix) r«riieao toiver actual data tfiroug in rale.miranmenei cordWons mf artvefsety aflcd wirelpss signa! rangc

Page 48: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

I A Di

visió

n of

Cisc

o Sy

stem

s, In

c.

2.4G

H:

Mod

el N

o W

AP

54

G

V2

Cisc

o SY

STEM

S

Page 49: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Appe

ndix

F: Sp

ecific

ation

sSt

anda

rds

Chan

nels

Ports

/But

tons

Cabli

ng T

ype

Data

Rat

e

Tran

smit P

ower

LEDs

Dim

ensio

ns(L

xWxH

)

Ante

nna

Heigh

t

Uni

tWei

ght

Powe

r

Cer

tifica

tions

Ope

ratin

gTem

p.

Stor

age

Tem

p.

802.

11g

and

802.

11 b

802.

11 g

11

Cha

nnels

(US,

Can

adá)

13 C

hann

els (E

urop

e)14

Cha

nnels

(Jap

an)

One

10/

100

RJ-

45 P

ort,

One

Pow

er P

ort,

One

Res

et B

utto

n

UTP

CAT

5 or

bet

ter

Up to

54M

bps

15dB

m

Powe

r, Ac

t, Lin

k

7.31

"x1

.88

" x

6.88

"(1

86 m

m x

48

mm

x 1

75 m

m)

4.5"

(11

4 m

m)

15

oz.

(0.4

2kg

)

Ext

erna

l,12V

DC

FCC,

Can

adá

0°C

to40

0C

(32°

Fto

104c

lF)

-200

Cto

700C

(-40

Fto

158°

F)

51

Page 50: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

AN EXO C

INFORMES DEL ANCHO DE BANDA DELENLACE A INTERNET.

Page 51: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ReporteEiecutivoOcupaciónSegundad

Cartera deProductos

NovedadesInpsat

Consultas

Gestión 7¿cr^;cí5 / Reporte Ejecutivo »

es calculado en tiempo rea!, en el horario de 09-19 Hs.

Direcciones IP de LANCASA MATRIZ (1024Kbps)

Ultima medición procesada:

Primera medición def día procesada: 9:00 Hs.

Tráfico desde su enlace hadaInternet

100% 0% < Utilización < 70%70% < Utilización < 80%

0% 80% < Utilización < 100%

Tráfico desde Internet; hada suenlace

100% 0% < Utilización < 70%70% < Utilización < 80%

0% 80% < Utilización < 100%

Page 52: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Ocupación de su enlace

Utilización del Enlace

Estadísticas actualizadas el Jueves 8 de Junio de 2006 a las 11:40:31

BANDWIDTH: 1024.0 kbits/s

Gráfico Diario (Promedio: $ minutos)

400 k

300 k

200 k

100 K

o k

- i

| . j ¡ jI T 1 "I" £ •9-$rfr-

08 10 12 14 16 18 20 22 00 02 04 06 OS 10

Max368.2 kb/s(36.0%)

108.3 kb/s(10.6%) Actual

Max Saliente: ^33" o%ifS Actua| Sa(jente:

319.7 kb/s(31.2%)51.2 kb/s(5.0%)

GráfÍCO Semanal (Promedio: 30 minutos)

Thu Frl Sat sun Mon Tue wed

- | 5

U- 8

Thu

Max

Max Saliente:

450.6 kb/s r

(44.0%) Kr0m'

w n i- *. 823.1 kb/sMaxP.coEnt: (8Q

640.1 kb/s(62.5%)

113.4 kb/s(11.1%) Actual

D. _ .' PlC° Ent:

Max

155.8 kb/s

(15.2%)29.8 kb/s(2.9%)

Actual Saliente:

„.PIC°

. . .ActU31

181.0 kb/s(17.7%)

287.9 kb/s(28.1%)24.6 kb/s(2.4%)

Mensual (Promedio: 2 horas)

Page 53: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Repo-te EiecutivoOcupaciónSegundad

Cartera do Productos

AcertijoGlosario

Consultas

Reporte Ejecutivo »

Este reporte es calculado en tiempo real, en e! horario de 09-19 Hs. de! icurso.

CASA MATRIZ (1024 Kbps) Direcciones IP de LAN

Ultima medición procesada:

J:ín/2;}06 - i 5: 20 Hs.Primera medición del día procesada: 9:00 I Is.

Trafico desde su enlace hada Internet98% 0% < Utilización < 70%

70% < Utilización < 80%l% 80% < Utilización < 100%

Tráfico desde Internet hada su enlace100% 0% < Utilización < 70%

70% < Utilización < 80%0% 80% < Utilización < 100%

Page 54: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Ocupación de su enlace

Utilización del Enlace

Estadísticas actualizadas el Lunes 3 de Julio de 2006 a las 15:25:41

BANDWIDTH: 1024.0 kbits/s

Gráfico Diario (Promedio: 5 minutos)

o 840 k•o

| 630 kOí

s_ 420 ko£i.

w 210 k4-*

CQ .

— i — i 1 — i 1 1—1 1 1 1 1 1 1 !

> * 1 1 » * 1 I 4 4 - I 1 * + 1

1 1 1 1— -1 1 1 1 1 1 1-

•— <• ¿ i i 4 * i i + ¿.....i.

....i i | i i i ¡ ; +.....Í — i.

.-*•-, i.- . /..i' *. i » • - i: i. -i it.Rm-.ii~.~f

10 12 14 16 18 20 22 00 02 04 06 08 10

M, , 825. 8 kb/s D .. . 90.7 kb/s A . . _Max L ^"-' (80.6%) Prom' •^•'••^•!-- (8.9%) Actual '- :;v; ;':

109 9 kh/s 7571 4 b/sMax Saliente: /Yn W? prom- Saliente: ,„ ™> Actual Saliente:(10.7%) (0.7%)

— \ . 1 — t-r ¡

i i U

\| Jwr-HwtL f12 14

253.4 kb/s(24.7%)

18.0 kb/s(1.8%)

Graneo Semanal (Promedio: 30 minutos)

840 k

g, 630 k•ui/ii_ 420 koa.

w 210 k4->

'£ o k

I—(—t—I—I-

10 12 14 16 18 20 22 00 02 04 06 08 10 12 14

Max . : • • = ; - 472.8 kb/s (46.2%) Prom. 'Max Saliente: 160.6 kb/s (15.7%) Prom. Saliente:Max Pico Ent.: 825.8 kb/s (80.6%) Prom. Pico Ent.:Max "u.o :-í!; : 420.7 kb/s (41.1%) Prom. PIÍ o -ni,:

125.8 kb/s (12.3%) Actual -,.::• :- .9201.9 b/s (0.9%) Actual Saliente:162.5 kb/s (15.9%) Actual Pico Ent.:24.5 kb/s (2.4%) Actual Pin) Sa; :

210.7 kb/s (20.6%)11.4 kb/s (1.1%)

229.9 kb/s (22.5%)29.4 kb/s (2.9%)

GráfícO Mensual (Promedio: 2 horas)

Page 55: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

840 k

210 k

o k, Ujrfl /' L^•_¿ L.» Ui-U \~í->

i V

i .

Á

r~J

•'yft->

- í

10 12 14 16 18 20 22 00 02 04 06 08 10 12

Max - ' • ! • „ :r<-"' 579.0 kb/s (56.5%) Prom. -w*,^-Max Saliente; 40.6 kb/s (4.0%) Prom. Saliente:Max Pico Ent: 877.8 kb/s (85.7%) Prom. Pico Ent.:Max ¡'ico <rt- : 640.1 kb/s (62.5%) Prom. P'co Sni,.

108.9 kb/s (10.6%)8401.7 b/s (0.8%)244.0 kb/s (23.8%)

75.2 kb/s (7.3%)

Actual !:::?!•; ,:¡.i->.--Actual Saliente;Actual Pico Ent.:Actual Í !KO S-;.

259.6 kb/s (25.4%)27.8 kb/s (2.7%)

825.8 kb/s (80.6%)107.0 kb/s (10.5%)

Gráfico Anual (Promedio: Idía)

840 k

630 k

42O k

.21 0 k '

I — — I

k.*

I — I

> <

ik

I — I

u,,

I — I

f í;..

i —i — i

Í ,, , , , A L ,

t—

I— —I

i_jt

f— II 1

1 1 i

1

i i

1 1

i J

1 1 ! ! ! ! ! !

í™"! ! r ? r

! ! í \ !

'! í í i í 1L^kjy^J

10 12 14 16 18 20 22 00 02 04 06 08 10 12 14

Max --••-.: \:-Max Saliente:Max Pico Ent.:Max Pie.- Sni.;

751. 2 kb/s (73.4%)938.0 kb/s (91.6%)

1023.7 kb/s (100.0%)1022.3 kb/s (99.8%)

Prom. LfT.i-rii.re::Prom. Saliente:Prom. Pico Ent:Prom. r*'CG Sai,:

148.7 kb/s (14.5%)54.8 kb/s (5. 3%)

468.2 kb/s (45. 7%)195.3 kb/s (19.1%)

Actual : ' ? 1 ; ¡ u:

Actual Saliente:Actual Pico Ent:Actual Pico S.-v :

35.7 kb/s (3.5%)1584.5 b/s (0.2%)171.6 kb/s (16.8%)109.9 kb/s (10.7%)

. . desde el Cliente hacia Internet^jen Bits o r Segundo jRojo Tráfico Saliente desde Internet hacia el Cliente, en Bits por Segundo ,Azul Tráfico entrante máximo en 5 minutosv- a, Tráfico saliente máximo en 5 minutos

Page 56: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ThinkíAhead !,?,,! *

Su Servicio '.^..v..- >Reporte EiecutivoOcupaciónSeguridad

Cartera de Productos

Novedades Impsat

Un gran Diferencial

Topología

Calidad de Servicie

AcertijoGlosano

Consultas

y Reporte Ejecutivo »

Este reporte es calculado en tiempo reai, en ei horario de 09-19 Hs. de3 día encursa,

CASA MATRIZ (1024 Kbps) Direcciones IP deLAN

Ultima medición procesada:

6/09/2*106- 13:05 Hs.Primera medición del dfa procesada: 9:00 Hs.

Tráfico desde su enlace fiadaInternet

I(K>% 0% < Utilización < 70%70% < Utilización < 80%

0% 80% < Utilización < 100%

Trafico desde Internet hada suenlace

100% 0% < Utilización < 70%70% < Utilización < 80%

0% 80% < Utilización < 100%

Page 57: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

,Ocupación de su enlace

Utilización del Enlace

Estadísticas actualizadas el Miércoles 6 de Septiembre de 2006 a las 13:05:21

BANDWIDTH: 1024.0 kbits/s

Gráfico Diario (Promedio: 5 minutos)

O k-1-08 10 12 14 16 18 20 22 00 02 04 06 08 1O 12

Max crí?;:>;¡<<::.

Max Saliente:

671.6 kb/s(65.6%) Prom. r niTí'íU"

Prom. Saliente:

73.2 kb/s(7.1%)

23.1 kb/s(2.3%)

Actual F ' : r r rh

Actual Saliente:

155.2 kb/s(15.2%)

32.8 kb/s(3.2%)

GráflCO Semanal (Promedio: 30 minutos)

760 k

Max ' y-;:<:

Max Saliente:

Max PicoEnt.:

Max rií '; SiU:

396.6 kb/sf3 O •7O/L\ JO. / so)

2(27761%/S683.9 kb/s(66.8%)

750.3 kb/s(73.3%)

Prom. É : iu f í í i * i í

Prom. Saliente:

Prom. PicoEnt.:

Prom, !!!i<:o S)L:

50.7 kb/s(5.0%)

9243.8 b/s(0.9%)

84.8 kb/s(8.3%)

29.4 kb/s(2.9%)

Actúan:- .,,,.

Actual Saliente:

Actual PicoEnt:

Actual H-:Ü £¡.¡; ;

116.7 kb/s(11.4%)

14.3 kb/s (1.4%)

152.9 kb/s(14.9%)

36.7 kb/s (3.6%)

GráflCO MenSUai (Promedio: 2 horas)

Page 58: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Max

Max Saliente:

Max PicoEnt:

Max Piro Sai.:

214.3 kb/s(20.9%)

103.4 kb/s(10.1%)

835.5 kb/s(81.6%)

893.0 kb/s(87.2%)

Prom.

Prom. Saliente:

Prom. PicoEnt:

Prom, Pico Sal.:

49.0 kb/s(4.8%)

7859.4 b/s(0.8%)

160.1 kb/s(15.6%)87.8 kb/s(8.6%)

Actual > - i i í - 3 ; : ! í - :

Actual Saliente:

Actual PicoEnt:

Actual Pico Ss! . :

107.1 kb/s(10.5%)34.3 kb/s(3.4%)

208.1 kb/s(20.3%)

214.9 kb/s(21.0%)

Anual (Promedio: 1 día)

1.2 M

jan Feb Mar ftpr May Jun TulAug Sep Oct Noy Dec

Max ;.-!-.Í.-C:ILO:

Max Saliente:

Max PicoEnt.:

Max Pico Síi¡ :

" —

751,2 kb/s(73.4%)

938,0 kb/s(91.6%)

1023.7 kb/s(100.0%)

1022.3 kb/s(99.8%)

n . 155. 7 kb/sProm.-u.-r,:.^- (152%)

_ _ . . . 38.6 kb/sProm. Saliente: (3 8%)

Prom. Pico 521.5 kb/sEnt: (50.9%)

n _. . 200.5 kb/sProm. hco^L: (ig 6%)

Referencias

< i» MI Tráfico Entrante desde el Cliente hacia Internet,Rojo

•Azul

Tráfico Saliente desde Internet hacia el Cliente,

Actual f.!'i:í¡r:;-.-

Actual Saliente:

70.8 kb/s(6.9%)

21. 9 kb/s(2.1%)

Actual Pico 671.6 kb/sEnt: (65.6%)

A^.^I o , - , r , 750. 3 kb/sActual ^to bílf (?33%)

en Bits por Segundo

en Bits por Segundo

'Tráfico entrante máximo en 5 minutos

Tráfico saliente máximo en 5 minutos

Page 59: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

AN EXO D

ANÁLISIS DE TRAFICO EN LOS ENLACESDE INTERCONEXIÓN.

Page 60: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ENLACE PRINCIPAL - 6 DE DICIEMBRE

SERVIDOR

WEB

ACCESS

ADISSION

EMAIL

SERVICEE

DNS

BDD

WSUS

SAES

STUDENT

LOAD

TOTAL

TRÁFICO PROMEDIO (Kbps)

749

117,161444

0,344

5,3525

0,51366667

2,215

3,259

2,253

105,247

0

3,147

988,492611

Tabla D.l Tráfico por servidor del enlace Principal - 6 de Diciembre

lóoct 17oct 18oct idoctSum • Bandwktth Truffic OUT

2ÜQCL

BsndwidBi Traffíc M \a D.l Tráfico del enlace Principal -6 de diciembre

Page 61: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ENLACE PRINCIPAL - CAAMAÑO 2

SERVIDOR

WEB

ACCESS

ADMISSION

EMAIL

SERVICEE

DNS

BDD

WSUS

SAES

STUDENT

LOAD

TOTAL

TRÁFICO PROMEDIO (Kbps)

469

104,247

0

3,3525

0

2,215

2,148

1,958

68,254

0

2,147

653,3215

1200

600

Tabla D.2 Tráfico por servidor del enlace Principal - Caamaño 2

10 oct 17 ott Wort 20 oct

Sum BaneMcfth Traffic OUT Bandwidth Trafftc IN

Figura D.2 Tráfico del enlace Principal - Caamaño 2

Page 62: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ENLACE PRINCIPAL - CAMPUS CAAMAÑO 1

SERVIDOR

WEB

ACCESS

ADISS1ON

EMAIL

SERVICEE

DNS

BDD

WSUS

SAES

STUDENT

LOAD

TOTAL

TRÁFICO PROMEDIO (Kbps)

750

220

1,25

10

0

0,215

3

2,253

110

0

3,147

1099,865

Tabla D.3 Tráfico por servidor del enlace Principal - Caamaño 1

3500

lóoct 17oct 18oct 19oct

Sum -Banctwidth Traffic OUT &&S Bandwictth Traffic \a D.3 Tráfico del enlace Principal - Caamaño 1

Page 63: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ENLACE PRINCIPAL - EXPO CENTURI

SERVIDOR

WEB

ACCESS

ADISSION

EMAIL

SERV1CEE

DNS

BDD

WSUS

SAES

STUDENT

LOAD

TOTAL

TRÁFICO PROMEDIO (Kbps)

500

110

0,344

15

0

4

6

2,253

150

0

3,147

790,744

Tabla D.4 Tráfico por servidor del enlace Principal - Expo Centuri

lóoct ISott líocl

Sum • BandwidthTraffic OUT V BandwidthTraffícÍH

Figura D.4 Tráfico del enlace Principal - Expo Centuri

Page 64: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

AN EXO E

ANÁLISIS DE TRÁFICO Y CARGA EN LOSSERVIDORES.

Page 65: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

SERVIDOR ACCESS

En la Figura E.1 y Figura E.2 se detallan los niveles de tráfico en 60 minutos y 24

horas, respectivamente. Para cada protocolo se asigna un color, para su fácil

distinción y posterior análisis.

(JveGrapti

Uii W Mnuln • 301« IntwvJ

i^ONS; Í.SH

Figura E.1 Tráfico en 60 minutos en el servidor ACCESS

Last 24 Hours

5 Mlnute(s) Average:

22QQ

2*00

1^00

1*00

I 1.400

¡ Í.200

> 1,000

800

eoo400

200

o14:00 16 iW 18:00 20 ¡00 22:00 00 «O 02:00 04;00 06 ¡O O 08:00

I Gther

( POP3j DN5I RDP

FTPSMTP

Í HTTPI S^4MP

! HTTP5 jg| ICMP • IMAP

; SSH . TELNET

Figura E.2 Tráfico en 24 horas en el servidor ACCESS

Page 66: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Can

tidad

de

Info

rmac

ión

Tra

nsm

itida

(K

Byt

e)

Pro

med

io

Máx

imo

Mín

imo

Oth

er

29.4

59,6

9

85.6

94,5

5

2.55

2,92

DN

S

46,1

54

161,

31

0,96

HT

TP

7.53

6,84

43.0

26,2

1

0,00

HT

TP

S

22,4

82

913,

30

0,00

ICM

P

9,88

199,

37

0,00

NE

TB

IOS

325,

301

11.1

28,7

5

2,06

RD

P

47;9

25

5.27

7,82

0,00

SMT

P

1.21

5,83

15.5

38,6

2

0,18

SNM

P

2,79

5

15,6

7

0,24

TE

LN

ET

0,00

0,06

0,00

85.6

94,5

5

Tab

la E

.l C

antid

ad d

e in

form

ació

n en

24

hora

s en

el s

ervi

dor

AC

CE

SS

Pro

med

io

Oth

er

DN

SH

TTP

H

TT

PS

IC

MP

N

ETB

IOS

R

DP

S

MT

P

SH

MP

TE

LHE

T

Fig

ura

E.3

Can

tidad

de

info

rmac

ión

tran

smiti

da e

n el

ser

vido

r A

CC

ESS

Page 67: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

29.459,69

46,154

47,925

1.215,83

JCMlfl IDNS

IRDP OSMTP

D HITP D HTTPS • ICMP

• SNMP • TELNET

INFIBIOS

Figura E.4 Cantidad de información promedio en el servidor ACCESS

Page 68: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Niv

ele

s d

e T

ráfi

co

(K

bp

s)

Prom

edio

Máx

imo

Mín

imo

Oth

er

802,

292

2.34

0,19

84,6

7

DN

S

1,26

9

4,41

0,03

HT

TP

206,

307

1.17

4,98

0,00

HT

TP

S

0,61

3

24,9

4

0,00

ICM

P

0,27

1

5,44

0,00

NE

TB

IOS

8,86

2

303,

90

0,06

RD

P

1,30

4

144,

13

0,00

SM

TP

33,4

59

424,

34

0,01

SN

MP

0,07

6

0,43

0,01

TE

LN

ET

0,00

0,00

0,00

Tab

la E

.2 N

ivel

es d

e tr

áfic

o en

el se

rvid

or

AC

CE

SS

2340

.19

Mín

imo

Máxim

o

Pro

med

io

Oth

erD

NS

HTT

P

HTT

PS

IC

MP

N

ETBI

OS

R

DP

SM

TP

S

NM

P TE

LNE

T

Fig

ura

E.5

N

ivel

es d

e tr

áfic

o en

el

serv

ido

r A

CC

ES

S

Page 69: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

1,2*9

602,192

1.3C4

31.459

a Qtter • ENS a HTTP nHTTPS • ICMP a NETBIOS

• RDP O SMTP «SMMP • TELNET

Figura E.6 Niveles de tráfico promedio en el servidor ACCESS

De las gráficas anteriores, se concluye que:

> El tráfico de mayor importancia en este servidor se encuentra en la

clasificación "other", que significa que no es reconocido por el analizador

utilizado, puede tratarse de tráfico P2P, ya que este protocolo no se incluye

en PRTG, y es muy utilizado para descargas.

Page 70: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

SERVIDOR ADMISSION

En la Figura E.7 y Figura E.8 se detallan los niveles de tráfico en 60 minutos y 24

horas, respectivamente.

Uil 60 MMwtsi • 30 i« Intcnnl

i

I Cnher $| DNS FTP gg HTTP fg HTTPS » ICMP • IMftP «IRC| POP3 B HDP SMTP ffl SNMP S5H TEUCT

Figura E.7 Tráfico en 60 minutos en el servidor ADMISSION

Last 24 Hours

24

**820

12(00 14¡00 16:00 IStOO 20KX3 22íOO 00:00 0?;OQ 040)0 063X1

OtherPOP3

DNS

ROPFTP a HTTPSMTP H SNMP

HTTPS

SSH

1MAP • IRC

Figura E.8 Tráfico en 24 horas en el servidor ADMISSION

Page 71: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Can

tidad

de

Info

rmac

ión

Tra

nsm

itida

(K

Byt

e)

Pro

med

io

Máx

imo

Mín

imo

Oth

er

0,00

1

0,00

0

0,00

0

DN

S

0,01

1

1,46

6

1,35

4

FT

P

0,00

0

0,00

0

0,00

0

HT

TP

5,61

4

1402

,278

20,7

HT

TP

S

0,48

3

79,6

2

57,9

NE

TB

IOS

43,8

74

143,

492

1,61

7

SMT

P

0,00

1

0,00

0

0,00

0

SN

MP

0,45

1

0,00

0

0,00

0

Tab

la E

.3 C

antid

ad d

e in

form

ació

n en

24

hora

s en

el s

ervi

dor

ADM

ISSI

ON

1402

,278

Oth

erDN

SFT

PK

TTP

HT

TPS

NET

BIO

SS

MT

P

Mín

imo

Máx

imo

Pro

med

io

SN

MP

Figu

ra E

.9 C

antid

ad d

e in

form

ació

n tr

ansm

itid

a en

el s

ervi

dor

ADM

ISSI

ON

Page 72: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

44,326 43^74

- -0,001

^ 0,451

Other • DNS D FTP El HTTP • HTTPS E NETBIOS • SMTP D SNMP

Figura E. 10 Cantidad de información promedio en el servidor ADMISSION

Page 73: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Niv

ele

s d

e T

ráfi

co

(K

bp

s)

Prom

edio

Máx

imo

Mín

imo

Oth

er

0,00

0

0,00

0

0,00

0

DN

S

0,00

0

0,00

0

0,00

0

FTP

0,00

0

0,00

0

0,00

0

HT

TP

0,15

3

38,2

94

4,24

6

HT

TP

S

0,01

3

2,17

4

0

NE

TB

IOS

1,19

8

3,91

9

1,11

6

SM

TP

0,00

0

0,00

0

0,00

0

SNM

P

0,01

2

0,00

0

0,00

0

Tab

la E

.4 N

ivel

es d

e tr

áfic

o en

el s

ervi

dor

ADM

ISSI

ON

38,2

94

Oth

er

DN

SFT

PH

TTP

KTTP

SN

ETB

IOS

SM

TP

SM

MP

Mín

imo

Máx

imo

Pro

med

io

Figu

ra E

.l 1

Niv

eles

de

tráf

ico

en e

l ser

vido

r AD

MIS

SIO

N

Page 74: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

1,21 1,198

O

0,012

Other • DNS D FTP ED HTTP • HTTPS Q NETBIOS • SWTTP G SNMP

Figura E. 12 Niveles de tráfico promedio en el servidor ADMISSION

De las gráficas anteriores, se concluye que:

> El tráfico de mayor importancia en este servidor se encuentra en la

clasificación "other", que significa que no es reconocido por el analizador

utilizado, puede tratarse de tráfico P2P, ya que este protocolo no se incluye

en PRTG, y es muy utilizado para descargas.

> Dado que en el presente servidor residen las aplicaciones de Test

Vocacional y Test de Admisiones, un tráfico significativo es el relacionado

con HTTP.

Page 75: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

SERVIDOR EMAIL

En la Figura E.13 y Figura E. 14 se detallan los niveles de tráfico en 60 minutos y

24 horas respectivamente.

1.100

1JKO

1.000

«o900

UveGraphUn W Mrww • 30 i*c Inurvil

• POP3

FTP ü HTTP i HTTPS MICMP • IMAP • IRC 1 NETBIQS

. SMTP M SNMP .;•' SSH TH/tT

Figura E.13 Tráfico en 60 minutos en el servidor EMAIL

Last 24 Hours

I Oth*f (Si DNS

I POP3 • RDP

FTP

SMTPHTTP

SNMP

HTTPS fi| 1CMP; S5M TELNET

Figura E.14 Tráfico en 24 horas en el servidor EMAIL

Page 76: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Can

tidad

de

Info

rmac

ión

Tran

smiti

da (

KB

yte)

Prom

edio

Máx

imo

Mín

imo

Oth

er

0,00

1

0,00

0

0,00

0

DN

S

108,

960

244,

445

1,03

7 :

HT

TP

2,10

8

602,

780

0,00

0

ICM

P

0,00

2

0,00

0

0,00

0

NE

TB

IOS

42,5

16

145,

353

3,15

9

SMT

P

630,

424

999,

783

1,01

8

Tab

la E

.5 C

antid

ad d

e in

form

ació

n en

24

hora

s en

el s

ervi

dor

EM

AIL 99

9,78

3

602,

780

Mín

imo

Máx

imo

Pro

med

io

Oth

erDN

SK

TTP

ICM

PN

ETB

IOS

SM

TP

Fig

ura

E.1

5 C

antid

ad d

e in

form

ació

n tr

ansm

itida

en

el s

ervi

dor

EM

AIL

Page 77: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

0,002

2,108

42,516

630,424

I Other D DNS ® HTTP n ICMP m NETBIOS • SMTP

Figura E.16 Cantidad de información promedio en el servidor EMAIL

Page 78: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Niv

eles

de

Trá

fico

(K

bps) Pr

omed

io

Máx

imo

Mín

imo

Oth

er

0,00

0

0 0

DN

S

2,97

5

677,

636

1,02

1

HT

TP

0,05

8

164,

61

0

ICM

P0,

000

0 0

NE

TB

IOS

1,16

1

3,96

9

1,03

0

SMT

P

17,2

16

284,

668

1,05

6

Tab

la E

.6 N

ivel

es d

e tr

áfic

o en

el s

ervi

dor

EM

AIL

677,

636

284,

668

Mín

imo

Máx

imo

Pro

med

io

Oth

erD

NS

H

TT

P

ICM

P

NE

TBIO

S

SM

TP

Fig

ura

E.17

Niv

eles

de

tráf

ico

en e

l ser

vido

r E

MA

IL

Page 79: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

1,161 17,216

I NETBIOS O SMTP

Figura E.18 Niveles de tráfico promedio en el servidor EMAIL

De las gráficas anteriores, se concluye que:

> El tráfico de mayor importancia en este servidor es el SMTP (Simple Mail

Transfer Protocol), lo cual concuerda, ya que la funcionalidad de dicho

servidor es el de manejar el correo electrónico.

Page 80: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

SERVIDOR SERVICES

En la Figura E.19 y Figura E.20 se detallan los niveles de tráfico en 60 minutos y

24 horas respectivamente.

UveGraphUn 60 FffnutM - 30 !*í Inwrvtl

| Other Ü DNS FTP U HTTP ü HTTPS H ICMP RIMAP • IRC }g NETBIOS| POP3 X M» SMTP M SNW - í SSH

Figura E.19 Tráfico en 60 minutos en el servidor SERVICES

Last 24 HoursAv«»q«i

I OtherI POP3

14:00 16 a» I8ÍH3 2QS>0 22*0 00:00 02iOft MiflO D£{00 08 «O 10:00

í DNS

I RDP

FTP g( HTTP J?3 HTTPS H ICMP • 1MAPSMTP « SNMP . SSH TEIMET

IRf: m NETBIOS

Figura E.20 Tráfico en 24 horas en el servidor SERVICES

Page 81: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

Cantidad de Información Transmitida (KByte)

Promedio

Máximo

Mínimo

DNS

0,00

3,819

0,00

NETBIOS

44,845

148,247

2,695

SMTP

0,00

645,056

0,00

Tabla E. 7 Cantidad de información en 24 horas en el servidor SER VICES

645.056

Mínimo

Máxima

Promedio

DNS NETBIOS SMTP

Figura E.21 Cantidad de información transmitida en el servidor SERVICES

44.845

!n DNS • ROMOS o SMTP

Figura E.22 Cantidad de información promedio en el servidor SERVICES

Page 82: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

Niveles de Tráfico (Kbps)

Promedio

Máximo

Mínimo

DNS

0,002

0,521

0,00

NETBIOS

1,226

4,048

0,074

SMTP

0,313

88,072

0,00

Tabla E.8 Niveles de tráfico en el servidor SERVICES

«8.072

Mínimo

Máximo

Promedio

DNS NETBIOS SMTP

Figura E.23 Niveles de tráfico en el servidor SERVICES

1.22Í

DDNS «NETBIOS D SMIP

Figura E.24 Niveles de tráfico promedio en el servidor SER VICES

Page 83: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

14,2(724992

5j095

360,91»

D Otiter • DNS D HTIP DICMP • NETBIOS m RDP • SMMP O ULNET • ETTIPS

Figura E.28 Cantidad de información promedio en el servidor DNS

Page 84: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Niv

eles

de

Tráf

ico

(Kbp

s) Prom

edio

Máx

imo

Mín

imo

Oth

er

8,21

8

27,5

21

1,08

1

DN

S

0,39

0

2,23

8

0,00

HT

TP

0,68

2

11,7

44

0,00

HT

TPS

0,00

0,03

0,00

1CM

P

0,13

9

0,60

6

0,01

4

NE

TB

IOS

1,64

6

5,61

6

0,06

1

RD

P

0,00

0,02

9

0,00

SNM

P

0,00

0,01

5

0,00

TE

LN

ET

0,00

0,00

2

0,00

27.5

21

Tab

la E

.10

Niv

eles

de

tráf

ico

en e

l ser

vido

r D

NS

Mín

i rno

Máxi

mo

Pro

medio

Oth

er

DN

S

HTT

P

KTT

PS

IC

M P

N

ETB

IOS

R

DP

S

NM

P TE

LNE

T

Figu

ra E

.29

Niv

eles

de

tráf

ico

en e

l ser

vido

r D

NS

Page 85: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

r-8,682

/-M39

nOÜ*r"DNS nHTTPnlCMP "NETBIOS • »DP • SNMP a TELNET •HTTPS

Figura E.30 Niveles de tráfico promedio en el servidor DNS

De las gráficas anteriores, se concluye que:

> El tráfico de mayor importancia en este servidor se encuentra en la

clasificación "other", que significa que no es reconocido por el analizador

utilizado, puede tratarse de tráfico P2P, ya que este protocolo no se

incluye en PRTG, y es muy utilizado para descargas.

> El tráfico DNS especifica la función que tiene el servidor de traslación de

nombres; además, se registra tráfico HTTP.

Page 86: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

AN EXO F

NUMERO DE PUNTOS DE RED, HOST EIMPRESORAS DE LA RED ACTUAL POR

DEPENDENCIA.

Page 87: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

RED ADMINISTRATIVA

CAMPUS PRINCIPAL

Planta Baja

UBICACIÓN

Admisión

Archivo

Biblioteca

Copiadora

Dirección Académica

Jefe de Control deRegistro TecnológicoJefe de SecretaríaAcadémica y RegistroCurricular

Recepción

Recepción de Registro

Registro 1

Registro 2

Sala de Audio

Sala de Profesores

Sala de Video

Secretaría Académica

Total

NUMEROHOST

5

I

4

1

1

3

1

I

1

1

3

1

0

1

3

27

NUMEROIMPRESORAS

I 1

--

1

..

--

--

--

~

i

--

1

--

--

-

2'

6

NUMEROPUNTOS DE RED

1

1

5

1

1

3

I

1

2

1

4

1

1

I

3

27

EQUIPOSADICIONALES

Switch

-

~

-

-

--

--

~

~

-

--

-

--

--

Switch

Tabla F.l Número de puntos de red, host e impresoras de la red administrativa en la

planta baja del campus Principal

1 La impresora se conecta a un host, no al punto de red.

Page 88: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Planta Alta

UBICACIÓN

Caja

Centro de Cómputo

Corredor

Redes y SAES

Tecnologías

Total

NÚMEROHOST

2

4

2

2

1

11

NUMEROIMPRESORAS

I2

I 1

--

--

--

2

NUMEROPUNTOS DE RED

2

3

2

2

1

10

EQUIPOSADICIONALES

--

Hub

--

--

-

Tabla F.2 Número de puntos de red, host e impresoras de la red administrativa en la

planta alta del campus Principal

CAAMAÑO 1

Planta Baja

UBICACIÓN

Corredor

Dirección de Arquitectura Interior

Oficina 1

Sala 2

Sala 3

Secretaría Académica

Total

NÚMEROHOST

0

1

1

0

0

~2

NUMEROIMPRESORAS

~

--

-

--

1

1

NÚMEROPUNTOS DE RED

1

1

1

2

3

1

9

Tabla F.3 Número de puntos de red, host e impresoras de la red administrativa en la

planta baja del campus Caamaño 1

La impresora se conecta a un host, no a un punto de red.

Page 89: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Planta Alta

UBICACIÓN

Coordinación de Educación ParvulariaSala de clases

Total

NÚMEROHOST

1

1

2

NÚMEROIMPRESORAS

-

--

-

NÚMEROPUNTOS DE RED

2

1

3

Tabla F.4 Número de punios de red, host e impresoras de la red administrativa en la

planta alta del campus Caamaño 1

CAAMAÑO 2

Planta Baja

UBICACIÓN

Coordinación de Ciencias Físicas y Matemáticas

Corredor

Decanato Ingeniería y Ciencias Agropecuarias

Dirección de Escuela de Comunicación

Secretaría Académica

Total

NÚMEROHOST

1

1

2

2

28

NÚMEROIMPRESORAS

--

-

-

~I3

I

NUMEROPUNTOS DE RED

1

1

2

2

2

8

Tabla F.5 Número de puntos de red, host e impresoras de la red administrativa en la

planta baja del campus Caamaño 2

Planta Alta

UBICACIÓN

Coordinación Publicidad, Diseño y MultimediaCoordinación de Sistemas, IngenieríaAgropecuaria y Medicina Veterinaria

Coordinación Comunicación Corporativa

Total

NÚMEROHOST

3

2

1

6

NÚMEROIMPRESORAS

--

-

--

-

NUMEROPUNTOS DE RED

3

2

1

6

Tabla F.6 Número de puntos de red, host e impresoras de la red administrativa en la

planta alta del campus Caamaño 2

La impresora se conecta a un host, no a un punto de red.

Page 90: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

CAMPUS 6 DE DICIEMBRE

Edificio Frontal

Planta Baja

UBICACIÓN

Decanato Ciencias Económicasy AdministrativasClub de EconomíaCoordinación de Economía yMDDDirección Asuntos Estudiantilesy DeportesCoordinación de Hotelería yTurismoOficina Sala 43

Oficina Sala 44

Recepción

Total

NUMEROHOST

2

2

3

1

2

2

4

2

18

NÚMEROIMPRESORAS

--

-

--

--

--

..

-

I 2

1

NUMEROPUNTOS DE RED

2

2

3

1

2

24

2

18

EQUIPOSADICIONALES

_

~

--

--

_.

--

-

Hub

--

Tabla F.7 Número de puntos de red, host e impresoras de la red administrativa en la

planta baja del edificio frontal del campus 6 de Diciembre

Planta Alta

UBICACIÓN

Coordinación deFormación GeneralDirección de FormaciónIntegra]

Dirección de Idiomas

Orientación Vocacional yApoyo Psicológico

Total

NÚMEROHOST

2

2

I

1

6

NÚMERO DEIMPRESORAS

--

I4

-

~

1

NUMERO PUNTOSDE RED

2

2

1

I

6

Tabla F.8 Número de puntos de red, host e impresoras de la red administrativa en la

planta baja del edificio frontal del campus 6 de Diciembre

La impresora se conecta a un host, no a un punto de red.

La impresora se encuentra conectada a un equipo de red (hub o switch).

Page 91: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Edificio Posterior

Planta Baja y Planta 1

UBICACIÓN

Coordinación de Administración y Finanzas

Coordinación Escuela de Tecnología

Estancia

Secretaría Académica

Total

NUMEROHOST

1

1

í

2

5

NUMEROIMPRESORAS

--

--

--

~

--

NUMEROPUNTOS DE RED

1

1

1

2

5

Tabla F.9 Número de puntos de red, host e impresoras de la red administrativa en la

planta baja y planta 1 del edificio posterior del campus 6 de Diciembre

Planta 2

UBICACIÓN

Coordinación Marketing

Coordinación Comercio Internacional

Total

NÚMEROHOST

2

2

4

NUMEROIMPRESORAS

-

--

NUMEROPUNTOS DE RED

3

2

5

Tabla F.10 Número de puntos de red, host e impresoras de la red administrativa en la

planta 2 del edificio posterior del campus 6 de Diciembre

Expo Centuri

UBICACIÓN

Admisiones

Auxiliar de Servicios y Compras

Boisa de empleo

Contabilidad

Control entrada/salida

Coordinación Maestría MBA

NUMEROHOST

5

I

1

3

1

1

NUMEROIMPRESORAS

-

-

--

1

-

-

NUMEROPUNTOS DE RED

5

1

1

4

I

I

Tabla F.ll Número de puntos de red, host e impresoras de la red administrativa en el

campus Expo Centuri

Page 92: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

UBICACIÓN

Dirección Administrativa y Finanzas

Dirección de Admisiones

Dirección de Finanzas

Dirección Maestría MBA

Jefatura de Finan c ¡amiento

Jefatura de Servicio y Compras

Jefatura Remuneración Impuestos

Matrículas

MBA

Rectorado

Sala de Reuniones

Secretaría Administrativa y Financiera

Secretaría de Jefatura

Secretaría de Rectorado

Vicerrectorado Académico

Vicerrectorado de Gestión

Total

NÚMEROHOST

1

1

1

1

1

1

1

1

1

1

0

1

1

1

1

1

27

NUMEROIMPRESORAS

1

--

--

1

--__

--

-

--

--

.

1

-

-

--

--

4

NUMEROPUNTOS DE RED

2

I

1

2

1

1

1

1

1

2

2

2

1

1

1

2

35

Tabla F.ll Número de puntos de red, host e impresoras de la red administrativa en el

campus Expo Centuri (continuación)

RED ESTUDIANTIL

CAMPUS PRINCIPAL

Planta Alta

UBICACIÓN

Laboratorio 20

Laboratorio 21

Laboratorio 22

Udlamático

Total

NÚMERO HOST

20

16

16

1

53

NÚMERO PUNTOS DE RED

20

16

16

1

53

Tabla F.12 Número de puntos de red, host e impresoras de la red estudiantil en la

planta alta del campus Principal

Page 93: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

AN EXO G

DISTRIBUCIÓN ACTUAL DE PUNTOS DERED.

Page 94: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

AN EXOI

APLICACIONES POR GRUPOS DE USUARIODE LA RED DE LA UDLA.

Page 95: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

GR

UPO

S D

E U

SU

AR

IOS

AD

MIN

IST

RA

TIV

OS

AP

AU

FlM

irO

S

;

CO

MU

NID

AD

i :

DE

PA

RT

AM

EN

TO

S

Fina

ncie

ro

Con

tabi

lidad

Siste

mas

Dec

anat

o

Secr

etar

ía A

cadé

mic

a

Bib

liote

caA

dmis

ione

s y

Tel

emar

ketin

g

Com

unic

ació

n C

orpo

rativ

a

Serv

icio

sC

oord

inac

ión

Reg

istr

o C

urri

cula

r

Rec

urso

s H

uman

os

Bolsa

de E

mpl

eoPr

esup

uest

os y

Ser

vici

os

Aut

orid

ades

Estu

dian

tes

Prof

esor

esC

omun

idad

Invi

tado

s E

xter

nos

Eve

ntos

y E

xpos

icio

nes

Chile

Lau

réat

e

Adm

inis

trac

ión

sist

emas

cont

able

s/fi

nanc

iero

si si no no no no no no no no no si no si no no no no no no no

Adm

inis

trac

ión

yge

stió

n es

tudi

antil

Si no si si si si si no no si i

si i

no no

ino

j

si

i

si no no j

no no no

iAP

LIC

AC

ION

ES

Acc

eso

a ar

chiv

osco

mpa

rtid

os

no no si si si no no no no si si no no no si si si no no no si

Bas

es d

eD

atos si si si si si no si si no si si si si si si si si no no no si

Apl

icac

ione

s1

St si SI si si SI SI si i

si si i

si i

si i

si no si si si no

\o i

no

:

si ¡

Apl

icac

ione

sM

ultim

edia

2

si si si si si si si si si si si si si si si no no no si si si

Tab

la L

l R

eque

rim

ient

os d

e la

s ap

lica

cion

es p

or g

rupo

s de

usu

ario

s

1 S

e re

fiere

a a

plic

acio

nes

adic

iona

les

que

son

requ

erid

as d

epen

dien

do d

e la

s fu

ncio

nes

que

se re

alic

en e

n ca

da d

epar

tam

ento

, m

ucha

s so

n de

sarro

llada

s in

tern

amen

te.

2 S

e re

fiere

a a

plic

acio

nes

de v

ideo

conf

eren

cia,

voz

sob

re IP

y v

ideo

.

Page 96: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXO J

PERFILES DE LOS LABORATORIOS DE LAUDLA.

Page 97: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

UB

ICA

CIÓ

N

I.A

BO

RA

TO

RIO

6

PAR

TIC

IÓN

Gen

eral

Sist

emas

LA

BO

RA

TO

RIO

S

LA

BO

RA

TO

RIO

SA

(M

AC

)

i

LA

BO

RA

TO

RIO

SB

(M

AC)

APL

ICA

CIÓ

N

Che

mla

b

Mac

rom

edia

Off

ice

2003

Ado

be

Offi

ce 2

003

SQL

Ser

ver

Mic

roso

ft V

isua

l St

udio

.Net

200

3 I

Fort

e fo

r Ja

va

Cos

tes

Aut

oDes

k In

vent

or

Com

man

der.

Off

ice

2003

Ado

be

Mac

rom

edia

Ofi

cceX

Ado

be

Ligh

twav

eM

acro

med

ia

i

Onc

ee 2

004

i

Ado

be

Lig

htw

ave

CO

NT

EN

IDO

Dre

amw

eave

r M

X,

Ext

ensi

ón

Man

ager

M

X,

Fire

wor

ks

MX

,Fr

eeH

and

MX

Acc

es,

Exc

el,

Fron

tPag

e, I

nfoP

ath,

Out

look

, Po

wer

Poin

t, Pr

ojec

t,Pu

blis

her,

Wor

d

Illu

stra

tor

10, P

hoto

shop

7.0

, Im

ageR

eady

7.0

Acc

es, E

xcel

, Inf

oPat

h, P

ower

Poin

t, Pu

blis

her,

Wor

d

(Ins

tala

ción

Tip

o C

lient

e - S

ervi

dor)

.

Acc

es, E

xcel

, Inf

oPat

h, O

utlo

ok,

Pow

erPo

int,

Publ

ishe

r,

Wor

d

Acr

obat

Dre

amw

eave

r M

X,

Ext

ensi

ón

Man

ager

M

X,

Fire

wor

ks

MX

,Fr

eeH

and

MX

i

Exc

el, O

utlo

ok,

Pow

erPo

int,

Wor

d

IHus

trato

r 10

, Ph

otos

hop

7.0,

Im

ageR

eady

7.0

Lig

htw

ave,

Hub

, Mod

eler

Dre

amw

eave

r 8.

0, F

lash

8.0

, Fir

ewor

ks 8

.0, F

reeH

and

MX

Exc

el 2

004,

Ent

oura

ge 2

004,

Pow

erPo

int

2004

, W

ord

2004

i

mus

trat

orC

S2,

Pho

tosh

op C

S2,

Imag

eRea

dy C

S2, I

nDes

ign

CS2

Lig

htw

ave,

Hub

, Mod

eler

ÁR

EA

Apl

icac

ione

sM

ultim

edia

Sist

emas

Apl

icac

ione

sM

ultim

edia

Apl

icac

ione

sM

ultim

edia

Apl

icac

ione

sM

ultim

edia

Tab

la J

.l P

erfil

es

de l

os l

abor

ator

ios

de l

a U

DLA

Page 98: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

JAB

OR

AT

OR

IO 2

0

LA

BO

RA

TO

RIO

21

/L

AB

OR

AT

OR

IO 2

2

Gen

eral

Sist

emas

Gen

eral

Sist

emas

Che

mla

b

Mac

rom

edia

Dre

amw

eave

r M

X,

Ext

ensi

ón

Man

ager

M

X,

Fire

wor

ks

MX

,F

reeH

andM

X

Mat

lab,

Mat

lab7

.1

j

Off

ice

2003

Ado

be

Aut

oCA

D

1

Off

ice

2003

SQL

Ser

ver

Mic

roso

ft V

isua

l St

udio

.Net

200

3

Ecl

ipse

(Ja

va)

i

Lin

ux K

nopi

x

Che

mla

b

Mac

rom

edia

Mat

lab,

Mat

lab7

.1

Off

ice

2003

Ado

be

Off

ice

2003

!

SQL

Serv

er

i

Mic

roso

ft V

isua

l St

udio

.Net

200

3 i

Ecl

ipse

(Ja

va)

Lin

ux K

nopi

x

Acc

es,

Exc

el,

Fron

tPag

e, I

nfoP

ath,

Out

look

, Po

wer

Poin

t, Pr

ojec

t,Pu

blis

her,

Wor

d

Illu

stra

tor

10, P

hoto

shop

7.0

, Im

ageR

eady

7.0

Acc

es, E

xcel

, Inf

oPat

h, P

ower

Poin

t, Pu

blis

her,

Wor

d

(Ins

tala

ción

Tip

o C

lient

e -

Serv

idor

).

i

Dre

amw

eave

r M

X,

Ext

ensi

ón

Man

ager

M

X,

Fire

wor

ks

MX

,F

reeH

andM

X

Acc

es,

Exc

el,

Fron

tPag

e, I

nfoP

ath,

Out

look

, Po

wer

Poin

t, Pr

ojec

t,Pu

blis

her,

Wor

d

nius

trat

or 1

0, P

hoto

shop

7.0

, Im

ageR

eady

7.0

Acc

es, E

xcel

, In

foPa

th,

Pow

erPo

int,

Publ

ishe

r, W

ord

(Ins

tala

ción

Tip

o C

hent

e -

Serv

idor

).

i ! :

Arq

uite

ctur

a

Sist

emas

Arq

uite

ctur

a

Sist

emas

Tab

la J

. 1 P

erfil

es d

e lo

s la

bora

tori

os d

e la

UD

LA (

cont

inua

ción

)

Page 99: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXOS

AN EXO K

DISTRIBUCIÓN FÍSICA DE LAS CÁMARAS IPEN EL CAMPUS SEDE NORTE.

Page 100: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

SYSTEM MANAGEMENT SERVER (SMS)

Es una completa herramienta que permitirá la gestión de inventario, gestión de

parches de seguridad y distribución de aplicaciones, necesarios para la

correcta administración de la red diseñada, estas tareas se las realiza de forma

remota desde un computador que tenga instalada la consola de administración

del SMS tal como si fuera un escritorio remoto o a través de tareas

programadas, su funcionamiento se explica a continuación.

Se instala el SMS en un servidor con sistema operativo Windows Server 2003,

y se crean las consolas de administración que pueden tener diferente tipo de

acceso dependiendo del usuario que vaya a manipularla, estas consolas son

instaladas en una computadora desde la cual se realiza el trabajo de

administración, con la consola de administración se descubre todos los equipos

que pertenecen a la red a través de el servidor de Active Directory cuyo

funcionamiento se explica en el apartado 3.9.2, una vez que se tienen todos los

equipos descubiertos se procede a hacerlos clientes del SMS para que sea

posible administrarlos remotamente, se puede clasificar a estos dientes en

grupos llamados colecciones para un mejor control de los mismos.

Con el SMS se puede realizar respaldos de la información automáticamente, se

debe configurar cuando hacerlos y donde guardarlos,

Gestión de inventario

Se tienen las opciones de realizar inventario de software y hardware, de esta

manera se puede tener un control de los programas que se tienen instalado,

cuando se los instaló y que usuario, verifica si se realizaron cambios de

hardware.

Es SMS proporciona las opciones de generar reportes, estos puede ser una

clasificación de equipos por sistema operativo, un determinado programa, uso

de los programas, actualizaciones de software o hardware realizadas, por

Page 101: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

dominio, procesador, memoria etc. Presenta informes completos del hardware

y software de un equipo seleccionado.

Gestión de parches de seguridad

El SMS permite el manejo de las actualizaciones de software necesarias para

mantener la seguridad de los equipos de la red, se tiene la posibilidad de

establecer a quien, cual, como y cuando se va a instalar una actualización.

Estas tareas pueden ser asistidas o no asistidas, asistidas significa que el

administrador debe realizar la actualización a través del escritorio remoto, y no

asistida se realiza a través de tareas configuradas sin necesidad de la

presencia del administrador.

Distribución de aplicaciones

Se tiene la posibilidad de instalar o desinstalar software completo de forma

asistida o no asistida, esta función puede funcionar en conjunto con la primera

ya que si se observa que un usuario instalo software no autorizado en su

computadora existe la posibilidad de desinstalarlo remotamente. Asi mismo se

facilita la instalación de software adicional.

Page 102: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

ANEXO O

DISTANCIA PARA LAS CONEXIONES DEFIBRA ÓPTICA PARA EL CAMPUS SEDE

NORTE.

Page 103: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

*ÉR

C£R

PIS

O

SE

GU

ND

OP

ISO

mm

m t>

iso

FLA

NTA

BA

JA

A-

3.5

m

60.1

3 m

Con

exió

n d

e fib

ra ó

ptic

a de

sde

el s

witc

h d

e C

OR

E h

acia

el d

e D

IST

RIB

UC

IÓN

de

cada

pis

o

3.5

m

3.5

m

3.5

m

Figu

ra O

.l C

onex

ione

s de

fibr

a óp

tica

en e

l cam

pus

Sede

Nor

te

Page 104: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

'ARTES EXCLUSIVE DISTRIBUTOR FOR .TENSEN TOOLS, U-S.A.!ONICA AUTHORIZED DISTRIBUTOR FOR ROBURN, U.S.A.

QUITO Plaza N21-202 y Roca * Teifs.: 256-4'-13 / 250-89-94 # Fax 256-41-55 • e-rra*!' tcparts@inieraclive net.ec « we& page" wvAViecoiPpanes.comCUENCA' Sucre 315 y Tilomas Gídóñez • Telf - £Ü7} 844-448 / fO?í 830-ís64 .-' e-mail aguüarg@aie 5Bi.net net

102 ROLLO Dt CABlt UÍP CATEGOhlA5£1440 P1.UGS RJ45 CATEGORÍAS

720 J^CK RJ46 CATEGORÍA -3E1 BACK METÁLICO ABIERTO DE PÍSO DE 2*•; RA<^K METÁLICO A81LR10 DE PISO DE 36; fXACK ^4EÍALiCü ASERTO OH PISO DE 44

i1/ PA.TCH PANUL DÜ.4y AÓRTICOS R.J4.5CATEGO4 MU L f U O fvIA PO LAR IZADA PARA RACK

TIEMPO Dt£ LNíT-íLíjA: !Nf-ÍCDM'

V/v IDí-'Z OF i.A OFFR'í'A íí> DÍAS

Page 105: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

LABORATORIO TÉCNICO EfraínlsaacVailejoGranizo

CON UN GRAN SURTIDO DE REPUESTOSPARA RADIO Y TELEVISIÓN

RUC: 0602823882001

P R O F O R M A

Av. República Oe1-63 (2063) y 10 de AgostoTelfs.: 2259 - 458 / 3319 - 287 Fax: 2259 - 459

QUITO - ECUADOR

Fecha:

Señor: é

Dirección

fc*

RUC/C,

TELF.:/"

CANT.

w^, -f v.;

L$S

,*~r •'-*••

<:A6 '•*'Lie:-

t ^ S

' *Z-.

" \ \N

•TVw c. *J •- X lo -:K:-,,c # S -

' > - ^ v ¿^ > I , ^ .0C tf ¿

";j -.;,: i " 7-i S O -,.. -r £ *

'T>^ - í - ^^ 'A c.L 7; ., c. ^ '\c -í ^K;^,,. '^v;c,. íT-

1 i<L"c v.---^- -. - c - •;, £> í O

:f- CC'Cic* ^ ? M ^ ÍH

Ai (. *• -^ ' - x<-\. i 3».

^c '< : ^ ic . :'r» 3 c-. > v. s •

DESCl

SÜB

SVA

F I R M A 1V , —

V, UNIT.

*"" v .. ". •>o ¿*•3.^0 ,

r, 1 o .i¿ ^'33o/^S

'-' ¿ < •'

c .^ ->.{ -y X-C-

ENTO $

TOTAL $

% $

OTAL $

^\R TOTAL

S H C . -•„ .. ,

'2s IG... .

i í, "1 -- -

^ ; . ; f * f f C

é C3 i \.

fi<4 ,.;Lc-

^ 't v,,

'5¿> . M! o

\ -^ S^'

w"í •T.;- •- /' r< • ?¿ --»v - - . f

-"> • ¡?-.\.. d -. J.. *"'

i lo j ti ,NOTA: Salida ía mercadería no se admite ningún reclamo

Page 106: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

YANEZ AVALOS CÍA, LTDA.

inistros para telecomunicaciones, fibra óptica, cables» consttoros y soluciones pü

coaxiaes,

COTIZACIÓN No.193

NOMBRE: ESTER PARRAFONO 92937702

FECHA:VALIDEZ:

9-Mar-078 DÍAS

CANT

831110144072017417

360360183511148

UND

UNDUNDUNDUNDUNDUNDUNDUNDUNDUNDUNDUNDUNDUNDUNDUND

DESCRIPCIÓN

COENCTORES SC QUEST MULTIMODOCABLE UTP CAT 5E QUESTCONECTOR RJ-45 QUEST CAT 5EJACK CAT 5E QUESTPATCH PANEL 48 P CAT 5E QUESTCOLUMNA MULTITOMA BEAUCOUP 4 TOMAS DOBLESORGANIZADOR DE CABLE 60X80 BEAUCOUPCAJETÍN DOBLE CON JACK CAT 5E QUESTFACE PLATE 2P CON ID BLANCO O MARFIL QUESTBANDEJA ESTÁNDAR 2UR BEAUCOUPF.O. 6 HILOS 62,5/1 25TIG! TT BUFFERRACK ABIERTO DE PISO 24 UR T. ENCAPSULADARACK ABIERTO DE PISO 36 UR T. ENCAPSULADARACK ABIERTO DE PISO 44 UR T. ENCAPSULADACAJA MULTIMEDIA 6P HUBBELLADAPTADOR DÚPLEX SC HUBBELL

PRECIOUNITARIO

6,500,460,353,00

154,4631,5012,067,101,44

15.402,15

95,00119,00131,00

15,9129,90

DSCTO%

22%22%22%22%22%22%22%22%22%22%22%22%22%22%22%22%

SUB-TOTALIVA. 12%TOTAL

VALORTOTAL

40,5611162,27

393,121684,802048,14

98,28159,92

1993,68404,35216,2258,7074,1092,82

102,1849,64

186,5818765,342251,84

21017,18

FORMA DE PAGO: A COVENiR

TIEMPO DE ENTREGA: CONFIRMADO STOCK INMEDIATO

•L/tAMPOVERDE

:NTEL

Av. i O de Agosto N37-Í16 y Av. Naciones Unidas * Telfs.: 02 2245 703 / 02 2271 898 - Quito - EcuadorCarlos Luis Piaza Dañín 206 y Peatonal D (P. Alt.) * Telfs.: (04) 2295 2S8 / 2235 664 » Guayaquil - Ecuador

E-maih henry.yanez^hentel• E-mail:

Page 107: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s
Page 108: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s
Page 109: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

Quito, D.M.marzo 26 del 2007

SeñoritaSoraya Carrasco

Presente.-

De nuestra consideración:

Según su requerimiento nos es grato hacerle llegar la siguiente cotización de los equipos

ÍT^M

1

2

3

4

5

6

7

8

9

10

11

12

CO&GO

DWL-2700AP

DWL-3200AP

DCS-5300

DCS-6620

DCS-70

DFL-1600

DFL-2500

DES-3550

DEM-311GT

DGS-3312SR

DEM-340MG

DEM-311GT

oiNPWNAccess Point OUTDOOR - Bridge, 2.4GHz, 2 antenasde 5dBif incluye PoE

Access Point INDOOR - Bridge, 2.4GHz, 2 antenas de5dBi, incluye PoE

Cámara PTZ, 1 puerto ethernet 10/100Mbps

Cámara PTZ, 1 puerto ethernet 10/100Mbps, Zommóptico lOx

Enclosure para cámaras DCS-5300/6620, Domo IP-66

Corporate &SMB Firewall y VPN Server, 6 puertosGígabit ethernet configurables

Corportate Firewall y VPN Server, 8 puertos Gigabitethernet configurables

SWITCH DE BORDE

Switch capa 2, 48 puertos 10/lOOMbps + 2 combogiga ethernet cobre/fibra

Puerto mini-Gbic para fibra óptica muftlmodo, 550mconector LC

SWITCH DE DISTRIBUCIÓN

Switch capa 2/3/4, 4-puertos 10/100/lOOOMbps, 2slots abiertos para cobre / fibra

Tarjeta para switch DGS-3312SR, 4 puertos SFP

Puerto mini-Gbic para fibra óptica multimodo, 550mconector LC

®WT

2

4

76

76

10

1

1

16

16

4

4

20

* UWÍ '•

992.00

238.00

460.00

1000.00

560.00

5400.00

10641.00

830.00

141.00

1540.00

214.00

141.00

ftTOTftt»

1984.00

952.00

34960.00

76000.00

5600.00

5400.00

10641.00

13280.00

2256.00

6160.00

856.00

2820.00

Page 110: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

13

14

15

16

DGS-3312SR

DEM-311GT

DXS-3326GSR

DEM-311GT

SWITCH PARA SERVIDORES

Switch capa 2/3/4, 4-puertos 10/100/lOOOMbps, 2slots abiertos para cobre / fibra

Puerto mini-Gbic para fibra óptica multimodo, 550mconecto r LC

SWITCH DE CORE

24-Puertos Gigabit Capa 2/3/4, 24-slot MiniGBIC conRPS (fuente redundante)

Puerto mini-Gbic para fibra óptica multimodo, 550mconecto r LC

2

8

1

6

1540.00

141.00

4605.00

141.00

TOTAL-

3080.00

1128.00

4605.00

846.00

m9&08

GARANTÍA: 1 AÑO CONTRA DEFECTOS DE FABRICACIÓNTIEMPO DE ENTREGA: 30 días previa orden de compra y entrega de anticipo del50%FORMA DE PAGO: 50%anticipo, 50% contraentrega.Estos precios están dados en dólares y no incluyen IVA.Esta cotización tiene validez de 15 días.

Cualquier inquietud, no dude en comunicarse con nosotros!!

En espera de gratas noticias, me despido

Ing. Dorís YánezCOORDINADOR DE PRODUCTOENLACE DIGITAL

Page 111: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

OFERTA REFERENCIAL - EQUIPOS

Cliente: SORAYA CARRASCO

Atención:

File:Fecha:

Páginas:

SCARRASCO-0391 -07-AM

27-Mar-2007

2

ÍTEM DESCRIPCIÓN CANT. PRECIOUNITARIO

US$

PRECIOTOTAL

US*

| SWITCH ACCESO

1 WS-C356Q-48TS-S Catalyst 356046 10/100 + 4 SFP Standard Image 1 S 4.322.34 $ 4,322.34

1 SWTTCH WSTWBUCI OH

2 WS-C4503 Catalyst 4500 Chassis (3-Slot),fan, no p/s3 PWR-C45-1300ACV Catalyst 4500 130QWAC Power Supply (Data and PoE)4 CAB-7513AC AC POWER CQKD NORTH AMERICA (110V)5 WS-X4515 Catalyst 4500 Supervisor IV (2 GE),Console(RJ-45)6 54KL3EK91-12220E' Cisco IOS ENHNCD L3 C4500 SLJP4/5.3DES(OSPF,EIGRP.IS-IS)7 WS-X43D6-GB Catalyst 4500 Gigabit Ethernet Module, Shorts (GBIC)8 WS-G5484 1QOOBASE-SX Snort Wawlength GBIC (Multimode otily)

Servicio de Mantenimiento Cisco9 CON-SNTP-WS-C451 24x7x4 Svc" Catalyst 4503R Series Modular Switch

| SWITCH CORE

10 WS-C4503 Calalysl 45DO Chassis (3-Slot).fan, no p/s11 PWR-C45-1300ACV Ca(alyst45QO 1300WAC Power Supply (Data and PoE)12 CAB-7513AC AC POWER CORD NORTH AMERICA (1 10V)13 WS-X4515 Calalysl 4500 Supervisor IV (2 GE).Console(RJ-45)14 S4KL3EKBM2220E'Cisco IOS ENHNCD 1.3 C4500 SUP4/5.3DES(OSPF,E1GRP,IS-1S}1 5 WS-X4306-GB Catalysl 4500 Gigabit Ethernet Module, 6-Ports (GBIC)16 WS-G5484 1000BASE-SX Short Wavelength GBIC (Mullimode only)

Servicio de Mantenimiento Claco17 CON-SNTP-WS-C451 24x7x4 3vc" Catalyst 45Q3R Serías Modular Switch

1 SWITCH SERVIDORES

1 8 WS-C4503 Calalyst 4500 Chassis (3-Slot),fan, no p/s19 PWR-C45-13QOACV Catalyst 4500 1300W AC Power Supply (Data and PoE)20 CAB-7513AC AC POWER CORD NORTH AMERICA(IIOV)21 WS-X451 5 Calalyst 4500 Supervisor IV (2 GE),Conso!e(RJ-45)22 S4KL3EK91-12220E1 Cisco IOS ENHNCD L3 C4500 SUP4/5,3DES(OSPF,EIGRP.IS-]S)23 WS-X4418-GB Catalysl 4500GE Module, Servar Swltchtng 16-Ports (GBIC)24 WS-G5484 1000BASE-SX Short Wawl en gth GBIC {Multimode only)

Servicio de Mantenimiento Claco25 CON-SNTP-WS-C45S 24x7x4 Sw:" Catalyst 4503R Series Modular Switch

1111115

1

1111116

1

1111115

1

S 861.01S 1,293.67$

$ 10,379.67S 8.649.01$ 2,591 67$ 432-67

$ 2,822.40

$ 861.01$ 1 .293 67$

$ 10,379.67£ 8.64B Q1S 2,591 .07S 432.67

$ 2.822.40

$ 861-01S 1,293.67$$ 10.379.67$ 8,649.01$ 8,649.01$ 43267

S 2,82240

S 861 .01S 1.293.67SS 10.379.67$ 8,649.01S 2,591.67$ 2,163 33

£ 2,82240

$ 86101$ 1,29367$$ 10.379.67S 8,649.01S 2,591.67£ 2.596.00

S 2,822.40

I

S 861.01$ 1,293.67i

$ 10,37967$ 8,64901$ 8,649 01$ 2,163 33

S 2,622.40

| ACCESS PO1NT EXTERNO

26 AIR-BR1310GA-K9 Aironat 1310 Ouldoor AP/Brw/Integrated Antenna, FCC Config 1 S 1,124.07 S 1,124.07

| ACCESS pomr INTERNO

27 AIR-AP1131AG-A-K9B02.11a, 1 1g AP, Int Radios, Ants, FCC Cnfg 1 $ 604.87 S 604.87

| CÁMARAS IP

28 SNC-CS11 Sony IP Camera with lens & POE. Modelo: SNC-CS11. Alta Resolución.Grabación tía imágenes a color. Ideal tanto para uso indoor como outdoor,soportan compresión JPEG y MPEG4, dispone de lente Servo CC da irisautomático y ofrece capacidad de acceso simultáneo, detecciónincorporada de movimiento y grabación pre y post alarma. Función detransferencia de audio bidireccional. Fabricante: Sony Procedencia: USA

$ 720.00

29 IMZ-RS316WW INTELLIGENT MONITORING SOFTWARE 16 CAMERAS. Modelo: IMZ-RS316WW

2,250.00 $ 2,250.00

Página 1 de 3

iaje Rosean EB-20 y Ai ShynsPBX. (593-2) 2443 BSB

Fax. E*t 102Casilla. 17-22-20254

Page 112: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

OFERTA REFERENCIAL - EQUIPOS

Cliente:Mención:

SORAYA CARRASCO File:

Fecha:Páginas:

SCARfWSCO-0381 JJ7-AM

27-War-2007

2

ÍTEM DESCRIPCIÓN CANT. PRECIOUNITARIO

US$

Nota: No se considera el Sistema de grabación da imágenes

Existen 2 opciones para el serwr. adquirir un Senador Sony que contiene laslicencias, software y hardware con el grabador de DVD de imágenes oadquirir las licencias con software e incorporarlas en un Storage

PRECIOTOTALUS*

1 SISTEMA DE TELEFONIA PARA ie8U3UAR10S

30 CISCO3B2S-CCME/K 3825 Volee Burtdle w/ PVDM2-64.FL-CCME-16B.SP Sarv,64F/256D31 S382USPSK9-12409 Cisco 3825 SPSK9-AESK9 FEAT SET FACTORY UPG FOR BUNDLES32 VIC2-2FXO Two-port Voics Interface Card - FXO (Uniwrsal)33 VWIC-1MFT-E1 1-Port RJ-48MuttffiexTrunx - E134 CAB-AC Power Cord,110V35 PWR-3825-AC Cisco 3825 AC pOwer supply36 ROUTER-SDM DeviCfl managerforrouters37 MEM3800-256D-INCI 256BM SDRAM default memoiy for 380038 MEM3800-64CF-INCIS4MB Cisco 3800 Compact Flash Memory Dflfaull39 FL-CCME-168 Cisco CaliManager Express Feal License Up To 166 Phones40 PVDM2-64 64-Channel Pachet Voice/FaxDSP Module

Servicio de Mantenimiento Cisco41 CON-SNTP-3825CCr SNT 24X7X4 + SAU 3825 Voice Bundle

1 $1 $1 $1 $1 S1 S1 S1 S1 31 S1 S

1 $

10,639.27 $2,16333 $

346.13 $1,12493 $

$- $

$

SSS£

2,166.32 $

i

10,639272,16333

346.131,124.93

-------

2.168.32

TELEFONO A42 CP-7940G Cisco IP Phone 794DG, Global

SW-CCM-UL-7940 CallManager Unit license for single 7940 IP phoneCP-PWR-CUBE-3 IP Phone power Iransformerforthe 7900 phone series

TELEFONO B43 ATA186-11-IP-CH1-A Cisco ATA 186 2-Port Adaplor With Switch, 600 Ohm Impedance

TELEFONO C44 CP-7911G Cisco IPPhona7911G

SW-CCM-UL-7911 CaliManager RTU Ücense tor Single IP Phone 7911CP-PWR-CUBE-3 IP Phone power translormer lor the 7900 phone series

TELEFONO D45 CP-7906G Cisco tP Phone 7906G

SW-CCME-UL-7906 Cisco CallManager Express License For Single 7906 IP PtioneCP-PWR-CUBE-3 IP Prtone power transformer for tha 7900 phone seríes

195.00 $

TOTAL A FACTURAR 119.2S7.57

Atentamente,

Ing. Adriana MolinaResponsableANDEANTRADE

taje Rosean E8-20 y Av EtyiisPBX (593-2) 2443*60

Fax Ett 102Castía. 17 22 20254

Quto Ecuador

Page 113: ESCUELA POLITÉCNICA NACIONALbibdigital.epn.edu.ec/bitstream/15000/463/4/T10437.pdf · 2.3.3.5 campus 91 expo centuri 2.3.3.5.1 mdf 91 2.3.3.5.2 sdf 92 2.3.4 sistema de tierra 9s

CONDICIONES GENERALES

Cliente: SORAYA CARRASCOAtención:

SCARRASCO-0381-07-AM

Fecha:

Pag:27-Mar-2Q07

TIEMPO DE ENTREGA- Chaisis de equipos: 45 días una vez cancelado el anticipo

FORMA DE PAGO- 50% anticipo y 50% a la entrega del equipo- Se especifica las cantidades con y sin IVA.

GARANTÍAEquipo Teletrontcs: Un arto contra defectos de fábricaAccesorios 90 días contra defectos de fábrica

TIEMPO DE VALIDEZ- Esta oferta tendrá una validez de treinta dias a partir de la fecha de la cotización

Atentamente,

Ing. Adriana MolinaResponsableANDEANTRADE

Página 3 de 3

Pasaje Rosean É8-20 y Av StiyrisPBX. (593-2) 2443-868

Fax; Ext, 102Casila; 17-22-20254

Quita Ecuador