13
PROJECT SITE PROJECT DIRECTORY OWNER: Todd Estabrook 69 Rutland St. #3 Boston MA, 02118 PHONE: (339) 222-4810 EMAIL: [email protected] APPLICABLE CODES BOSTON, MASSACHUSETTS DESCRIPTION CODE REFERENCE REQUIREMENT PROPOSED GENERAL CONSTRUCTION TYPE CODE SUMMARY 1. BUILDING : 780 CMR 9th EDITION LOCATION MAP ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE: (617) 504-2599 EMAIL: [email protected] CONTRACTOR: B H Brown Landscape Design PO Box 170622 Boston MA 02117 CONTACT: Ben Brown PHONE: (617) 792-7178 EMAIL: [email protected] III B III B JOB #: SCALE: DATE: DWN BY: CROSS REF: 3/27/2020 9:49:06 AM Z:\Jobs\Estabrook Residence\REVIT\69 Rutland St. corrected.rvt 1/4" = 1'-0" Cover A0.0 69 Rutland St. Unit #3 Boston, MA 02118 1960 Estabrook Residence Roof Deck Repair TK 2020-02-26 EXISTING DECK AND HEADHOUSE Estabrook Residence Roof Deck Repair 02/26/2020 Approvals Set Scope: Replace the existing floor finish on an existing roof deck. The existing deck footprint will remain unchanged. The existing building is a four-storey-plus-basement apartment building in South End. The scope of work is limited to the existing roof deck belonging to Unit #3. No other work is proposed. 69 Rutland St. Unit #3 Boston, MA 02118 Sheet List Sheet Number Sheet Name Current Revision Current Revision Date A0.0 Cover A0.1 Mortgage Plan and Zoning Summary A0.2 Existing Photos A0.3 Existing Photos A1.1 Demolition Roof Plan A1.2 Demolition Deck Elevations A1.3 Demolition Deck Elevations A1.4 Demolition Building Elevations A2.1 Proposed Roof Plan A2.2 Proposed Deck Elevations A2.3 Proposed Deck Elevations A2.4 Roof Head House Elevations A2.5 Proposed Building Elevations

Estabrook Residence OWNER: ARCHITECT: CONTRACTOR: Roof ... · 2/26/2020  · ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE:

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Estabrook Residence OWNER: ARCHITECT: CONTRACTOR: Roof ... · 2/26/2020  · ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE:

PROJECT SITE

PROJECT DIRECTORY

OWNER:Todd Estabrook69 Rutland St. #3Boston MA, 02118PHONE: (339) 222-4810EMAIL: [email protected]

APPLICABLE CODES BOSTON, MASSACHUSETTS

DESCRIPTION CODE REFERENCE REQUIREMENT PROPOSED

GENERAL

CONSTRUCTION TYPE

CODE SUMMARY

1. BUILDING : 780 CMR 9th EDITION

LOCATION MAP

ARCHITECT:Derek Rubinoff, Architect82 Spring StreetWest Roxbury, MA 02132CONTACT: Derek RubinoffMOBILE: (617) 504-2599EMAIL: [email protected]

CONTRACTOR:B H Brown Landscape DesignPO Box 170622Boston MA 02117CONTACT: Ben BrownPHONE: (617) 792-7178EMAIL: [email protected]

III B III B

JOB #:SCALE:DATE:DWN BY:CROSS REF:

3/27/2020 9:49:06 AM Z:\Jobs\Estabrook Residence\REVIT\69 Rutland St. corrected.rvt

1/4" = 1'-0"

CoverA0.069 Rutland St. Unit #3

Boston, MA 02118

1960Estabrook Residence Roof Deck Repair

TK2020-02-26

EXISTING DECK AND HEADHOUSE

Estabrook Residence Roof Deck Repair02/26/2020 Approvals Set

Scope:

Replace the existing floor finish on an existing roof deck. The existing deck footprint will remain unchanged.

The existing building is a four-storey-plus-basement apartment building in South End. The scope of work is limited to the existing roof deck belonging to Unit #3.

No other work is proposed.

69 Rutland St. Unit #3Boston, MA 02118

Sheet List

SheetNumber Sheet Name

CurrentRevision

CurrentRevision

Date

A0.0 CoverA0.1 Mortgage Plan and Zoning

SummaryA0.2 Existing PhotosA0.3 Existing PhotosA1.1 Demolition Roof PlanA1.2 Demolition Deck ElevationsA1.3 Demolition Deck ElevationsA1.4 Demolition Building ElevationsA2.1 Proposed Roof PlanA2.2 Proposed Deck ElevationsA2.3 Proposed Deck ElevationsA2.4 Roof Head House ElevationsA2.5 Proposed Building Elevations

Page 2: Estabrook Residence OWNER: ARCHITECT: CONTRACTOR: Roof ... · 2/26/2020  · ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE:

ZONING SUMMARY

DESCRIPTIONGENERAL

CODE REFERENCE REQUIRED/ALLOWED EXISTING

Zoning District: South End Neighborhood (Article 64)Sub District: MFR (Multifamily Residential)Overlay: Groundwater Conservation; Restricted ParkingHistoric District: South End Landmark DistrictParking Freeze Zone: Boston Proper ZoneParks Design Review: Ordinance 7.4-11Map: 1PYear Built: ~1900. Roof deck and headhouse are existing. Headhouse appears to have historic stair within; see photos.

USE RESIDENTIAL USES:THREE-FAMILY ROW HOUSE ALLOWED

§64 TABLE A

PARKING 1.0 SPACES PER DWELLING UNIT 2

3 APARTMENT UNITS

FRONT YARD MIN. DEPTH CONFORM WITH EXISTING BUILDING ALIGNMENT

§64 TABLE C CONFORMS

PROPOSED

NO CHANGE

LOT AREA MIN. FOR DWELLING UNIT §64 TABLE C N/A N/A

USABLE OPEN SPACE MIN. PER UNIT 460 SF FOR UNIT 3 (ROOF DECK)

LOT WIDTH MIN. 21'

FAR MAX. §64 TABLE C 2.0 UNIT 1 = 1,532 SFUNIT 2 = 711 SFUNIT 3 = 1,607 SF

BUILDING TOTAL = 3,850 SF (PER ASSR.)

EXISTING FAR = 2.0

NO CHANGE

BUILDING HEIGHT MAX. 70'§64 TABLE C 66' NO CHANGE

NUMBER OF STOREYS NO LIMIT§64 TABLE C 4 + HEADHOUSE NO CHANGE

REAR YARD MIN. DEPTH 20'§64 TABLE C 30'

NONE

SIDE YARD MIN. WIDTH NONE§64 TABLE C NONE

NONE

§64 TABLE C

LOT FRONTAGE MIN. 21'NONE§64 TABLE C

200 SF PER DWELLING UNIT§64 TABLE C NO CHANGE

NO CHANGE

NO CHANGE

NO CHANGE

§64 TABLE H NO CHANGE

NO CHANGE

NO CHANGE

ROOF DECK STRUCTURES MUST GET BOA CONDITIONAL USE IF ALTERS THE PROFILE AND/OR CONFIGURATION OF THE ROOF OR MANSARD.

MUST BE ON A ROOF WITH < 5 DEG. SLOPE.DECK MUST BE < 12" ABOVE HIGHEST POINT ON ROOF. TOTAL HEIGHT OF BUILDING INCLUDING DECK MUST BE ≤ MAX ALLOWABLE BUILDING HEIGHT. TOP OF BULKHEAD MUST BE ≤ 30" ABOVE DECK. AN APPURTENANT HAND RAIL, BALUSTRADE, HATCH, OR BULKHEAD IS SET BACK HORIZONTALLY, 2' FOR EACH FOOT OF HEIGHT OF SUCH APPURTENANT STRUCTURE, FROM A ROOF EDGE THAT FACES A STREET MORE THAN 20' WIDE.

ROOF DECKS INCLUDING DECKING AND RAILING SHOULD NOT BE VISIBLE FROM ANY PUBLIC WAY. PARTIAL VISIBILITY OF THE RAILING MAY BE ALLOWED ON A CASE-BY-CASE BASIS....ANY VISIBLE RAILINGS MUST BE BLACK METAL.

DOES NOT ALTER THE ROOF OR MANSARD PROFILE.

EXISTING DECK HEIGHT APPEARS TO BE <12" ABOVE THE HIGHEST POINT OF THE ROOF (DIFFICULT TO DETERMINE WITHOUT EXPLORATORY DEMOLITON). TOP OF EXISTING HEADHOUSE IS WITHIN OVERALL ALLOWED BUILDNG HEIGHT BUT 6'-10" ABOVE THE TOP OF THE DECK (>30" ABOVE TOP OF DECK; NEEDS ZONING RELIEF). EXISTING ROOF SLOPE IS SLIGHTLY LESS THAN 5 DEGREES.

DECK IS NOT VISIBLE FROM PUBLIC WAYS; SEE PHOTOS. FRONT AND REAR EDGE OF RAILINGS ARE PARTIALLY VISIBLE.

§64-34

SOUTH END LANDMARKS DISTRICT CRITERIA I.(F)

PROPOSED CONFORMS (WOULD MATCH EXISTING; SEE PHOTOS).

ROOF DECK HEIGHT WOULD MATCH EXISTING. NO PROPOSED CHANGES TO EXISTING HEADHOUSE.

NO CHANGE TO EXISTING CONFIGURATION, EXCEPT ANY WOOD RAILINGS VISIBLE FROM PUBLIC WAYS WILL BE CHANGED TO METAL RAILINGS. EXISTING METAL RAILINGS AT FRONT AND REAR WILL BE RE-INSTALLED BUT WILL HAVE HEIGHT INCREASED TO 42" ABOVE DECK IN ACCORDANCE WITH 780 CMR.

LOT AREA §64 TABLE C LOT SIZE: 1,890 SF (21' x 90') NO CHANGEPARCEL 0900460000

ADDITIONAL LOT AREA FOR DWELLING UNIT

§64 TABLE C N/A N/ANONE

REAR YARD MAX OCC BY ACCESSORY 25%§64 TABLE C NONE NO CHANGE

460 SFDeck Open Space Area

Open Space Area Legend

Usable Open Space

JOB #:SCALE:DATE:DWN BY:CROSS REF:

3/27/2020 9:49:12 AM Z:\Jobs\Estabrook Residence\REVIT\69 Rutland St. corrected.rvt

As indicated

Mortgage Plan and Zoning SummaryA0.169 Rutland St. Unit #3

Boston, MA 02118

1960Estabrook Residence Roof Deck Repair

Author2020-02-26

1" = 30'-0"1 Mortgage Plan1" = 10'-0"2 Roof Deck Open Space Area Plan

Page 3: Estabrook Residence OWNER: ARCHITECT: CONTRACTOR: Roof ... · 2/26/2020  · ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE:

JOB #:SCALE:DATE:DWN BY:CROSS REF:

3/27/2020 9:49:23 AM Z:\Jobs\Estabrook Residence\REVIT\69 Rutland St. corrected.rvt

Existing PhotosA0.269 Rutland St. Unit #3

Boston, MA 02118

1960Estabrook Residence Roof Deck Repair

Author2020-02-26

EXISTING COMPOSITE DECK FLOORING

EXISTING COMPOSITE RAILINGS

EXISTING METAL RAILINGS.

EXISTING COUNTER AND GRILL

EXISTING PARAPET AND COPING

EXISTING CLAPBOARD HEAD HOUSE

EXISTING COMPOSITE DECK SCREEN

EXISTING FURNITURE AND PLANTERS ON THE DECK

Page 4: Estabrook Residence OWNER: ARCHITECT: CONTRACTOR: Roof ... · 2/26/2020  · ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE:

JOB #:SCALE:DATE:DWN BY:CROSS REF:

3/27/2020 9:49:37 AM Z:\Jobs\Estabrook Residence\REVIT\69 Rutland St. corrected.rvt

Existing PhotosA0.369 Rutland St. Unit #3

Boston, MA 02118

1960Estabrook Residence Roof Deck Repair

Author2020-02-26

DECK IS BARELY VISIBLE FROM STREET OR FROM REAR ALLEY. EXISTING FOURTH FLOOR IS PRESENTLY BUILT OUT AT FRONT AND REAR.

VIEW LOOKING SOUTH SHOWS OTHER

NEIGHBORING ROOF DECKS

VIEW LOOKING NORTH SHOWS

OTHER NEIGHBORING ROOF

DECKS

EXISTING HEADHOUSE

HISTORIC STAIR WITHIN EXISTING HEAD HOUSE

NOTE:THE ONLY PROPOSED CHANGE FROM THE EXISTING FROM THE POINT OF VIEW OF THOSE ON A PUBLIC WAY IS THAT ALL VISIBLE (FROM A PUBLIC WAY) RAILINGS WILL BE BLACK METAL.

Page 5: Estabrook Residence OWNER: ARCHITECT: CONTRACTOR: Roof ... · 2/26/2020  · ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE:

DN

DN

8' - 3 5/8" 33' - 0 7/8" DECK 5' - 3 1/8"

18' -

5 1

/2"

18' -

10"

5 7/

8"

8' - 5" 6' - 7 1/4" 18' - 0 5/8"

8' - 3 5/8" 9' - 11 7/8"

HEADHOUSE

12' - 10" 10' - 3" 5' - 3 1/8"

55' - 6 1/4"

54' - 0 1/4"

19' -

3 7

/8" D

ECK

A1.2

1

A1.2 2A1.3

1

A1.32

8' - 3 5/8" 9' - 11 7/8" 23' - 1" 5' - 3 1/8"

RU

TLAN

D S

TREE

T (B

ELO

W)

ADJACENT BUILDING

ADJACENT BUILDING

REA

R (W

EST

HAV

EN S

TREE

T BE

LOW

)

AREA OF CONTRACT

EXISTING HEADHOUSE AND IN-UNIT STAIR TO BELOW.TO REMAIN.

DEMOLISH EXISTING COMPOSITE RAILINGS AND POSTS, TYPICAL.

EXISTING CHIMNEY

EXISTING CONDENSER (NOT VISIBLE FROM STREET; SCREENED AT

SIDES)

EXISTING CHIMNEY

EXISTING GUTTER

REMOVE EXISTING METAL RAILINGS AND SAVE FOR REUSE.

EXISTING GUTTER

EXISTING EXTERIOR KITCHEN TO REMAIN. DISCONNECT EQUIPMENT AND STORE FOR

REUSE.

2.08%

2.08%

1

2

A2.5 1

A2.52

HEA

DH

OU

SE

4' -

8 1/

4"

EXISTING TURFED PAD FOR DOGS.

REMOVE EXISTING LOW-HEIGHT WOOD STORAGE TRUNKS AND SAVE.

REMOVE EXISTING

WOOD SCULPTURE

PEDISTALS AND SAVE.

REMOVE EXISTING PLANTERS AND SAVE.

REMOVE FURNISHING AND SAVE

DEMOLITION NOTES

DEMOLISH THE EXISTING DECK FLOORING ONLY; DECK STRUCTURE TO REMAIN.

REMOVE ALL EXISTING FURNITURE, COUNTER, GAS GRILL, SINK (UNCONNECTED) AND PLANTERS AND SAVE FOR FUTURE USE.

1

2

EXISTING PARTITION

DEMO PLAN LEGEND

TO BE DEMOLISHED

JOB #:SCALE:DATE:DWN BY:CROSS REF:

3/27/2020 9:49:42 AM Z:\Jobs\Estabrook Residence\REVIT\69 Rutland St. corrected.rvt

As indicated

Demolition Roof PlanA1.169 Rutland St. Unit #3

Boston, MA 02118

1960Estabrook Residence Roof Deck Repair

TK2020-02-26

1/4" = 1'-0"1 Demolition Roof Plan

Page 6: Estabrook Residence OWNER: ARCHITECT: CONTRACTOR: Roof ... · 2/26/2020  · ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE:

3' -

3"

1' -

9"

AREA OF CONTRACT

DEMOLISH EXSITING COMPOSITE DECK FLOORING; DECK STRUCTURE TO REMAIN.

REMOVE COMPOSITE DECK SCREEN AND COMPOSITE RAILING AND SAVE FOR REUSE, TYPICAL.

EXISTING CLAPBOARD HEAD HOUSE WITH COPPER GUTTERS ENTIRELY TO REMAIN.

EXISTING EPDM MEMBRANE TO REMAIN.

EXISTING EPDM MEMBRANE TO REMAIN.

EXISTING GUTTER TO REMAIN.

REMOVE EXISTING PLANTERS AND SAVE FOR REUSE.

REMOVE EXISTING EQUIPMENT AND SAVE FOR REUSE. CAP CONNECTIONS.

TOP

OF

HIG

HES

T PO

INT

ON

RO

OF

TOP

OF

DEC

K 10

1/8

" ABO

VE

Top of Roof Ridge54' - 8 1/8"

AREA OF CONTRACTDEMOLISH EXSITING COMPOSITE DECK

FLOORING; DECK STRUCTURE TO REMAIN.

REMOVE EXISTING METAL AND COMPOSITE RAILING.STORE METAL RAILING FOR REUSE.

EXISTING PARAPET TO REMAIN, TYPICAL.

REMOVE COMPOSITE DECK SCREEN AND COMPOSITE RAILING. REMOVE EXISTING

COUNTER, EQUIPMENT, AND PLANTERS FOR REUSE.

Top of Roof Ridge54' - 8 1/8"

JOB #:SCALE:DATE:DWN BY:CROSS REF:

3/27/2020 9:49:46 AM Z:\Jobs\Estabrook Residence\REVIT\69 Rutland St. corrected.rvt

1/4" = 1'-0"

Demolition Deck ElevationsA1.269 Rutland St. Unit #3

Boston, MA 02118

1960Estabrook Residence Roof Deck Repair

TK2020-02-26

1/4" = 1'-0"1Demolition Exterior Elevation Facing Northat Headhouse

1/4" = 1'-0"2 Demolition Exterior Elevation Facing East

Page 7: Estabrook Residence OWNER: ARCHITECT: CONTRACTOR: Roof ... · 2/26/2020  · ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE:

AREA OF CONTRACT

DEMOLISH EXISTING COMPOSITE DECK FLOORING; DECK STRUCTURE TO REMAIN.

DEMOLISH EXISTING COMPOSITE RAILING.

EXISTING GUTTER.

EXISTING EPDM ROOF TO REMAIN.

DEMOLISH THE EXISTING CLAPBOARD WALL FOR INSTALLING NEW METAL RAILING.

REMOVE COMPOSITE DECK SCREEN AND COMPOSITE RAILING AND SAVE FOR REUSE, TYPICAL.

EXISTING GUTTER

Top of Roof Ridge54' - 8 1/8"

AREA OF CONTRACT

DEMOLISH EXISTING COMPOSITE DECK FLOORING; DECK STRUCTURE TO REMAIN.

REMOVE EXISTING METAL RAILING AND SAVE FOR REUSE.

REMOVE EXISTING PLANTERS AND SAVE FOR REUSE, TYPICAL.

EXISTING DEMISING WALL COPING TO REMAIN, TYPICAL.

Top of Roof Ridge54' - 8 1/8"

TYPICAL: REMOVE PEDISTAL FURNISHINGS (FOR SCULPTURES); SAVE.

JOB #:SCALE:DATE:DWN BY:CROSS REF:

3/27/2020 9:49:50 AM Z:\Jobs\Estabrook Residence\REVIT\69 Rutland St. corrected.rvt

1/4" = 1'-0"

Demolition Deck ElevationsA1.369 Rutland St. Unit #3

Boston, MA 02118

1960Estabrook Residence Roof Deck Repair

TK2020-02-26

1/4" = 1'-0"1 Demolition Exterior Elevation Facing South

1/4" = 1'-0"2 Demolition Exterior Elevation Facing West

Page 8: Estabrook Residence OWNER: ARCHITECT: CONTRACTOR: Roof ... · 2/26/2020  · ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE:

First Floor6' - 3"

Second Floor18' - 3"

Fourth Floor42' - 3"

Third Floor30' - 3"

Top of Roof Ridge54' - 8 1/8"

REMOVE EXISTING METAL RAILING AND SAVE FOR REUSE.

EXISTING HEADHOUSE TO REMAIN

AREA OF WORK

First Floor6' - 3"

Second Floor18' - 3"

Fourth Floor42' - 3"

Third Floor30' - 3"

HEI

GH

T AB

OVE

AVE

RAG

E G

RAD

E

65' -

8 1

/2"

HEI

GH

T AB

OVE

TO

P O

F D

ECK

6' -

9 1/

4"

TOP

OF

DEC

K <

12" A

BOVE

TO

P O

F R

OO

F R

IDG

E10

1/8

"

8.72%

REMOVE EXISTING METAL RAILING AND SAVE FOR REUSE.

EXISTING HEADHOUSE TO REMAIN

Top of Roof Ridge54' - 8 1/8"

AREA OF WORK

JOB #:SCALE:DATE:DWN BY:CROSS REF:

3/27/2020 9:49:55 AM Z:\Jobs\Estabrook Residence\REVIT\69 Rutland St. corrected.rvt

1/8" = 1'-0"

Demolition Building ElevationsA1.469 Rutland St. Unit #3

Boston, MA 02118

1960Estabrook Residence Roof Deck Repair

TK2020-02-26

1/8" = 1'-0"2 Rear (East) Building Demolition Elevation

1/8" = 1'-0"1 Front (West) Building Demolition Elevation

Page 9: Estabrook Residence OWNER: ARCHITECT: CONTRACTOR: Roof ... · 2/26/2020  · ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE:

DN

DN

A2.2

1

2A2.32

1

A2.4

1

A2.4 2

A2.4

3 A2.44

BLAC

K M

ETAL

RAI

L IN

G

18' -

5 1

/2"

RU

TLAN

D S

TREE

T (B

ELO

W)

ADJACENT BUILDING

ADJACENT BUILDING

REA

R (W

EST

HAV

EN S

TREE

T BE

LOW

)

54' - 0 1/4"

5' MINIMUM

8' - 3 5/8"

METAL RAILING

10' - 5 7/8"

EXISTING HEADHOUSE TO REMAIN

11' - 10"

COMPOSITE RAILING

10' - 9"

5' MINIMUM

5' - 3 1/8"

45' - 0 7/8"

AREA OF CONTRACT

12

BLAC

K M

ETAL

RAI

LIN

G

18' -

6"

TYPICAL: REPLACE ALL COMPOSITE RAILINGS WITH NEW COMPOSITE RAILINGS.

REINSTALL EXISTING METAL RAILINGS. ADJUST HEIGHT TO BE 42" AFF.

EXISTING HEADHOUSE TO REMAIN AS IS.

INSTALL BLACK METAL RAILING.

METAL POSTS AT OUTSIDE CORNERS

(WHERE MAY BE VISIBLE FROM PUBLIC WAY)

METAL POSTS AT OUTSIDE CORNERS

(WHERE MAY BE VISIBLE FROM PUBLIC WAY)

55' - 6 1/4"

A2.52

18' -

10"

5 7/

8"

19' -

3 7

/8" D

ECK

EXISTING EPDM ROOF

EXISTING GUTTER

EXISTING GUTTER

EXISTING EPDM ROOF

2.08% 2.08%

REINSTALL TURFED PAD (ON DECK SURFACE) FOR DOGS.

REINSTALL SCULPTURE

PEDISTAL FURNISHINGS

REINSTALL FURNISHINGS

REINSTALL FURNISHING

REINSTALL PLANTERS

EXISTING CONDENER; REINSTALL SCREEN

CONSTRUCTION PLAN KEY NOTES

TYPICAL: INSTALL PVC DECK FLOORING IN PLACE OF EXISTING.

REINSTALL THE EXISTING FURNITURE, COUNTER , GAS, GRILL, AND PLANTERS ON THE REPLACED FLOORING.

TYPICAL: ALL RAILINGS ARE TO BE INSTALLED PER 780 CMR, INCLUDING STRUCTURAL REQUIREMENTS. RAILINGS HEIGHTS TO BE 42" MIN AFF. BALUSTERS 4" O.C., MAX. RE-INSTALL ANY POSTS WITH PROPER EPDM SLEVES SO AS TO MAKE WATER-TIGHT; ANY REPAIRS OR ADJUSTMENTS TO EPDM ROOF MEMBRANE MUST FOLLOW MEMBRANE MANUFACTURER'S INSTRUCTIONS. ALL ITEMS INSTALLED ON ROOF MUST BE SECURED TO RESIST WIND LOADS. ALL WORK MUST COMPLY WITH 780 CMR AND BOSTON ZONING CODE.

1

2

EXISTING PARTITION

NEW PARTITION

PLAN LEGEND

JOB #:SCALE:DATE:DWN BY:CROSS REF:

3/27/2020 9:50:00 AM Z:\Jobs\Estabrook Residence\REVIT\69 Rutland St. corrected.rvt

As indicated

Proposed Roof PlanA2.169 Rutland St. Unit #3

Boston, MA 02118

1960Estabrook Residence Roof Deck Repair

TK2020-02-261/4" = 1'-0"1 Proposed Roof Plan

Page 10: Estabrook Residence OWNER: ARCHITECT: CONTRACTOR: Roof ... · 2/26/2020  · ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE:

AREA OF CONTRACT

INSTALL NEW PVC FLOOR ON EXISTING STRUCTURE.

INSTALL COMPOSITE DECK SCREEN AND COMPOSITE RAILING.

EXISTING CLAPBOARD HEAD HOUSE TO REMAIN.

EXISTING EPDM MEMBRANE TO REMAIN.

EXISTING EPDM MEMBRANE TO

REMAIN.

INSTALL BLACK METAL RAILING. MUST RESIST LATERAL FORCES AS

REQUIRED BY CODE. TOP RAIL 42" AFF. BALLUSTERS 4" O.C.

Top of Roof Ridge54' - 8 1/8"

HIG

HES

T PO

INT

ON

RO

OF

TOP

OF

DEC

K 10

1/8

" ABO

VE

TYPICAL: BLACK METAL 2"x2" POSTS AT OUSIDE CORNERS. SECURE TO

STRUCTURE AND MEND ROOF WITH WATERTIGHT SLEVE.

3' -

6"

2.08%2.08%

5' MIN. SETBACK

5' - 3 1/8"

5' MIN. SETBACK

8' - 3 1/2"

REINSTALL EXISTING BLACK METAL RAILING. ADJUST HEIGHT TO BE 42" AFF.REINSTALL EXISTING BLACK

METAL RAILING. ADJUST HEIGHT TO BE 42" AFF.

BLACK METAL RAILING

9' - 3 3/4"

COMPOSITE RAILING

9' - 7 3/8"

REINSTALL WOOD SCULPTURE PEDISTAL FURNISHINGS, TYP.

AREA OF CONTRACT

INSTALL NEW PVC FLOOR ON EXISTING STRUCTURE IN EXACTLY THE SAME PLACE/HEIGHT.

REINSTALL EXISTING METAL RAILING. ADJUST SO TOP OF RAILING IS 42" AFF (TYPCAL). SPHERE OF 4" MUST NOT BE ABLE TO PASS THROUGH BALUSTERS (TYPICAL). ALL RAILINGS MUST RESIST LATERAL FORCES AS REQUIRED BY CODE (TYPICAL).

EXISTING PARAPET TO REMAIN, TYPICAL.

INSTALL COMPOSITE DECK SCREEN AND COMPOSITE RAILING.

Top of Roof Ridge54' - 8 1/8"

3' -

6"

16' - 6" BLACK METAL RAILING

JOB #:SCALE:DATE:DWN BY:CROSS REF:

3/27/2020 9:50:04 AM Z:\Jobs\Estabrook Residence\REVIT\69 Rutland St. corrected.rvt

1/4" = 1'-0"

Proposed Deck ElevationsA2.269 Rutland St. Unit #3

Boston, MA 02118

1960Estabrook Residence Roof Deck Repair

TK2020-02-26

1/4" = 1'-0"1Proposed Exterior Elevation Facing North atHeadhouse

1/4" = 1'-0"2 Proposed Exterior Elevation Facing East

Page 11: Estabrook Residence OWNER: ARCHITECT: CONTRACTOR: Roof ... · 2/26/2020  · ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE:

AREA OF CONTRACT

INSTALL NEW PVC FLOOR ON EXISTING STRUCTURE.

INSTALL PVC RAILING SYSTEM, MIN. 42" RAILING HEIGHT ABOVE DECK.

EXISTING GUTTER.

EXISTING EPDM ROOF TO REMAIN.

INSTALL 42" HIGH BLACK METAL RAILING.

Top of Roof Ridge54' - 8 1/8"

3' -

6"

REINSTALL EXISTING BLACK METAL RAILING. MODIFY TO MAKE HEIGHT 42" AFF.

REINSTALL EXISTING BLACK METAL RAILING.

MODIFY TO MAKE HEIGHT 42" AFF.

COMPOSITE 42" HIGH RAILING WITH BALUSTERS @ 4" O.C.

24' - 8 7/8"

METAL RAILING & POSTS

7' - 9 3/8"

AREA OF CONTRACT

INSTALL NEW PVC FLOOR ON EXISTING STRUCTURE.

REINSTALL EXISTING METAL RAILING. MUST RESIST LATERAL FORCES AS REQUIRED BY CODE. ADJUST HEIGHT TO BE 42" AFF.

REINSTALL EXISTING PLANTERS, TYPICAL.

EXISTING DEMISING WALL COPING TO REMAIN, TYPICAL.

Top of Roof Ridge54' - 8 1/8"

REINSTALL WOOD SCULPTURE PEDISTAL FURNISHINGS, TYP.

JOB #:SCALE:DATE:DWN BY:CROSS REF:

3/27/2020 9:50:08 AM Z:\Jobs\Estabrook Residence\REVIT\69 Rutland St. corrected.rvt

1/4" = 1'-0"

Proposed Deck ElevationsA2.369 Rutland St. Unit #3

Boston, MA 02118

1960Estabrook Residence Roof Deck Repair

TK2020-02-26

1/4" = 1'-0"1 Proposed Exterior Elevation Facing South

1/4" = 1'-0"2 Proposed Exterior Elevation Facing West

Page 12: Estabrook Residence OWNER: ARCHITECT: CONTRACTOR: Roof ... · 2/26/2020  · ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE:

7' -

7 3/

4"

Top of Roof Ridge54' - 8 1/8"

7' -

3 5/

8"

Top of Roof Ridge54' - 8 1/8"

6' -

3 5/

8"

ABO

VE E

XIST

ING

AN

D N

EW D

ECK

FIN

ISH

TOP

OF

EXIS

TIN

G T

O R

EMAI

N H

EAD

HO

USE

6' -

9 1/

4"

EXISTING EPDM ROOF

EXT'G DECK WITH PROPOSED FINISH (SAME HT/THICKNESS AS EXISTING)

7' -

2 7/

8"

Top of Roof Ridge54' - 8 1/8"

6' -

3 5/

8"10

1/8

"

7' -

9 3/

8"

7' -

3 3/

4"

Top of Roof Ridge54' - 8 1/8"

JOB #:SCALE:DATE:DWN BY:CROSS REF:

3/27/2020 9:50:12 AM Z:\Jobs\Estabrook Residence\REVIT\69 Rutland St. corrected.rvt

1/2" = 1'-0"

Roof Head House ElevationsA2.469 Rutland St. Unit #3

Boston, MA 02118

1960Estabrook Residence Roof Deck Repair

TK2020-02-26

1/2" = 1'-0"1 Elevation of Headhouse, Facing S1/2" = 1'-0"2 Elevation of Headhouse, Facing E

1/2" = 1'-0"3 Elevation of Headhouse, Facing N1/2" = 1'-0"4 Elevation of Headhouse, Facing W

NOTE: EXISTING CLAPBOARD HEAD HOUSE IS TO REMAIN ( NO PROPOSED CHANGES). EXISTING TO REMAIN WINDOWS AND DOOR ARE NOT VISIBLE FROM ANY PUBLIC WAY.

Page 13: Estabrook Residence OWNER: ARCHITECT: CONTRACTOR: Roof ... · 2/26/2020  · ARCHITECT: Derek Rubinoff, Architect 82 Spring Street West Roxbury, MA 02132 CONTACT: Derek Rubinoff MOBILE:

First Floor6' - 3"

Second Floor18' - 3"

Fourth Floor42' - 3"

Third Floor30' - 3"

Top of Roof Ridge54' - 8 1/8"

HEI

GH

T AB

OVE

AVE

RAG

E G

RAD

E

65' -

8 1

/2"

8.72%

REINSTALL EXISTING BLACK METAL RAILING

EXISTING HEADHOUSE TO REMAINAREA OF WORK

First Floor6' - 3"

Second Floor18' - 3"

Fourth Floor42' - 3"

Third Floor30' - 3"

Top of Roof Ridge54' - 8 1/8"

REINSALL EXISTING METAL RAILING

EXISTING HEADHOUSE TO REMAIN

AREA OF WORK

JOB #:SCALE:DATE:DWN BY:CROSS REF:

3/27/2020 9:50:17 AM Z:\Jobs\Estabrook Residence\REVIT\69 Rutland St. corrected.rvt

1/8" = 1'-0"

Proposed Building ElevationsA2.569 Rutland St. Unit #3

Boston, MA 02118

1960Estabrook Residence Roof Deck Repair

Author2020-02-26

1/8" = 1'-0"1 Front (West) Building Proposed Elevation1/8" = 1'-0"2 Rear (East) Building Proposed Elevation