Note: This test report is for the customer shown above and their specific product only. It may not be duplicated or used in part without prior written consent from Bay Area Compliance Laboratories Corp.(Shenzhen). This report must not be used by the customer to claim product certification, approval, or endorsement by NVLAP, NIST or any agency of the Federal Government.
ETSI EN 301 489-3 V1.4.1 (2002-08)
EMC MEASUREMENT AND TEST REPORT
For
Shenzhen Gospell Smarthome Electronic Co., Ltd
5 Floor/Block 2, Vision (SZ) Park, Hi-Tech Industrial Park, Shenzhen, P.R.China
Model: GP-708
This Report Concerns:
Original Report
Equipment Type:
2.4G Wireless Receiver
Test Engineer: Cinderallar Chen and Amanda Wei
Report No.: RSZ07121302-2
Test Date: 2007-12-27 to 2007-12-28
Report Date:
2008-01-04
Reviewed By: EMC Manager: Green Xu
Prepared By: Bay Area Compliance Laboratories Corp.(Shenzhen) 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China Tel: +86-755-33320018 Fax: +86-755-33320008
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 2 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
TABLE OF CONTENTS GENERAL INFORMATION.......................................................................................................................................4
PRODUCT DESCRIPTION FOR EQUIPMENT UNDER TEST (EUT) ....................................................................................4 OBJECTIVE ...................................................................................................................................................................4 RELATED SUBMITTAL(S)/GRANT(S).............................................................................................................................4 TEST METHODOLOGY ..................................................................................................................................................4 TEST FACILITY.............................................................................................................................................................4 LOCAL SUPPORT EQUIPMENT LIST AND DETAILS ........................................................................................................5 EXTERNAL I/O CABLE .................................................................................................................................................5
SYSTEM TEST CONFIGURATION..........................................................................................................................6 JUSTIFICATION .............................................................................................................................................................6 EUT EXERCISE SOFTWARE..........................................................................................................................................6 SPECIAL ACCESSORIES.................................................................................................................................................6 BLOCK DIAGRAM/SCHEMATICS ...................................................................................................................................6 EQUIPMENT MODIFICATIONS .......................................................................................................................................6 CONFIGURATION OF TEST SETUP .................................................................................................................................7 BLOCK DIAGRAM OF TEST SETUP ................................................................................................................................7
SUMMARY OF TEST RESULTS ...............................................................................................................................8
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.1 - CONDUCTED EMISSIONS................................................................9 MEASUREMENT UNCERTAINTY....................................................................................................................................9 EUT SETUP..................................................................................................................................................................9 EMI TEST RECEIVER SETUP ......................................................................................................................................10 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................10 TEST PROCEDURE ......................................................................................................................................................10 TEST RESULTS SUMMARY..........................................................................................................................................10 TEST DATA ................................................................................................................................................................11 PLOT(S) OF TEST DATA..............................................................................................................................................11
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.1 - RADIATED EMISSIONS ..................................................................14 MEASUREMENT UNCERTAINTY..................................................................................................................................14 EUT SETUP................................................................................................................................................................14 EMI TEST RECEIVER SETUP ......................................................................................................................................15 TEST EQUIPMENT LIST AND DETAILS.........................................................................................................................15 TEST PROCEDURE ......................................................................................................................................................15 CORRECTED AMPLITUDE & MARGIN CALCULATION .................................................................................................15 TEST DATA ................................................................................................................................................................16
EN 61000-3-2-HARMONIC CURRENT EMISSIONS............................................................................................17 TEST EQUIPMENT.......................................................................................................................................................17 TEST SYSTEM SETUP..................................................................................................................................................17 TEST STANDARD ........................................................................................................................................................17 TEST DATA AND SETUP PHOTO..................................................................................................................................17
EN 61000-3-3- VOLTAGE FLUCTUATION AND FLICKER...............................................................................22 TEST EQUIPMENT.......................................................................................................................................................22 TEST SYSTEM SETUP..................................................................................................................................................22 TEST STANDARD ........................................................................................................................................................22 TEST DATA AND SETUP PHOTO..................................................................................................................................23
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.2 RF ELECTROMAGNETIC FIELD (80 MHz -1000 MHz and 1400 MHz –2000 MHz).........................................................................................................................................................24
TEST EQUIPMENT.......................................................................................................................................................24 TEST SYSTEM SETUP..................................................................................................................................................24 TEST STANDARD ........................................................................................................................................................25 TEST PROCEDURE ......................................................................................................................................................25 TEST DATA AND SETUP PHOTO..................................................................................................................................25
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 3 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.2 ELECTROSTATIC DISCHARGE .....................................................27 TEST EQUIPMENT.......................................................................................................................................................27 TEST SYSTEM SETUP..................................................................................................................................................27 TEST STANDARD ........................................................................................................................................................27 TEST PROCEDURE ......................................................................................................................................................28 TEST DATA AND SETUP PHOTO..................................................................................................................................29
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.2- IMMUNITY: FAST TRANSIENTS COMMON MODE.................31 TEST EQUIPMENT.......................................................................................................................................................31 TEST SYSTEM SETUP..................................................................................................................................................31 TEST STANDARD ........................................................................................................................................................31 TEST PROCEDURE ......................................................................................................................................................32 TEST DATA AND SETUP PHOTO..................................................................................................................................32
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.2- IMMUNITY: RF COMMON MODE 0.15 MHz To 80 MHz ..........33 TEST EQUIPMENT.......................................................................................................................................................33 TEST SETUP................................................................................................................................................................33 TEST STANDARD ........................................................................................................................................................33 TEST PROCEDURE ......................................................................................................................................................34 TEST DATA AND SETUP PHOTO..................................................................................................................................34
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.2- IMMUNITY: SURGES, LINE TO LINE AND LINE TO GROUND36 TEST EQUIPMENT.......................................................................................................................................................36 TEST SYSTEM SETUP..................................................................................................................................................36 TEST STANDARD ........................................................................................................................................................36 TEST PROCEDURE ......................................................................................................................................................37 TEST DATA AND SETUP PHOTO..................................................................................................................................37
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.2- IMMUNITY: VOLTAGE DIPS AND INTERRUPTIONS..............38 TEST EQUIPMENT.......................................................................................................................................................38 TEST SETUP................................................................................................................................................................38 TEST STANDARD ........................................................................................................................................................38 TEST PROCEDURE ......................................................................................................................................................39 TEST
ATA AND
S
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 4 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
GENERAL INFORMATION Product Description for Equipment Under Test (EUT) The Shenzhen Gospell Smarthome Electronic Co.,Ltd ’s product, model GP-708, or the "EUT" as referred to in this report is a 2.4G Wireless Receiver which measures approximately 7.2 cm L x 6.6 cm W x 1.1cm H, rated input voltage: DC 8V adapter. SWITCHING MODE POWER SUPPLY Model: GP006DE Input: 100-240VAC, 50/60Hz, 0.3A; Output: 8V 500mA, 4 VA MAX LPS * All measurement and test data in this report was gathered from production sample serial number: 0712016(Assigned by BACL, Shenzhen). The EUT was received on 2007-12-13. Objective The following report is prepared on behalf of Shenzhen Gospell Smarthome Electronic Co., Ltd. in accordance with ETSI EN 301 489-3 V1.4.1 (2002-08), Electromagnetic compatibility and Radio spectrum Matters (ERM); Electromagnetic Compatibility (EMC) standard for radio equipment and services; Part 3: Specific conditions for Short-Range Device (SRD) operating on frequencies between 9 kHz and 40 GHz. The objective is to determine compliance with ETSI EN 301 489-3 V1.4.1 (2002-08). Related Submittal(s)/Grant(s) No Related Submittals. Test Methodology All measurements contained in this report were conducted with ETSI EN 301 489-1 V1.7.1 (2007-04). Test Facility The Test site used by Bay Area Compliance Laboratories Corp. (Shenzhen) to collect test data is located in the 6/F, the 3rd Phase of WanLi Industrial Building, ShiHua Road, FuTian Free Trade Zone Shenzhen, Guangdong, China. Test site at Bay Area Compliance Laboratories Corp. (Shenzhen) has been fully described in reports submitted to the Federal Communication Commission (FCC). The details of these reports have been found to be in compliance with the requirements of Section 2.948 of the FCC Rules on November 04, 2004. The facility also complies with the radiated and AC line conducted test site criteria set forth in ANSI C63.4-2003. The Federal Communications Commission has the reports on file and is listed under FCC Registration No.: 382179. The test site has been approved by the FCC for public use and is listed in the FCC Public Access Link (PAL) database.
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 5 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Additionally, Bay Area Compliance Laboratories Corp. (Shenzhen) is a National Institute of Standards and Technology (NIST) accredited laboratory, under the National Voluntary Laboratory Accredited Program (Lab Code 200707-0). The current scope of accreditations can be found at http://ts.nist.gov/ts/htdocs/210/214/scopes/2007070.htm. Local Support Equipment List and Details
Manufacturer Description Model Serial Number FCC ID
Sumsung Color Display 225 MS CR22HVIP401073M DoC
External I/O Cable
Cable Description Length (M) From/Port To
Unshielded Detachable AC Mains Cable 1.70 EUT Adapter
Unshielded Detachable A/V Cable 1.10 EUT Monitor
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 6 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
SYSTEM TEST CONFIGURATION Justification The system was configured for testing in a typical fashion (as normally used by a typical user). EUT Exercise Software N/A Special Accessories N/A Block Diagram/Schematics Please refer to the Exhibit D. Equipment Modifications No modifications were made to the EUT.
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 7 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Configuration of Test Setup Block Diagram of Test Setup
EUT
1.0 Meter
1.5 Meter
1.5 Meter
EUT
LISN
Non-Conducting Table 150 cm above Ground Plane
Adapter
Monitor10cm
Monitor
AC Mains A/V Cable
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 8 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
SUMMARY OF TEST RESULTS ETSI EN 301 489-3 V1.4.1 (2002-08)
Rule Description of Test Result
§7.1 Reference to clauses EN 301 489-1 §8.4 AC mains power input/output ports Compliant
§7.1 Reference to clauses EN 301 489-1§8.3 DC power input/output ports N/A
§7.1 Reference to clauses EN 301 489-1
§8.2 Enclosure of ancillary equipment measured on a stand alone basis
Compliant
§7.1 Reference to clauses EN 301 489-1 §8.5 Harmonic current emissions (AC mains input port) Compliant
§7.1 Reference to clauses EN 301 489-1 §8.6 Voltage fluctuations and flicker (AC mains input port) Compliant
§7.1 Reference to clauses EN 301 489-1§8.7 Telecommunication ports N/A
§7.2 Reference to clauses EN 301 489-1
§9.2 Radio frequency electromagnetic field (80 MHz to 1 000 MHz and 1 400 MHz to 2 000 MHz)(EN 61000-4-3)
Compliant
§7.2 Reference to clauses EN 301 489-1 §9.3 Electrostatic discharge (EN 61000-4-2) Compliant
§7.2 Reference to clauses EN 301 489-1§9.4 Fast transients, common mode (EN 61000-4-4) Compliant
§7.2 Reference to clauses EN 301 489-1§9.5 Radio frequency, common mode (EN 61000-4-6) Compliant
§7.2 Reference to clauses EN 301 489-1
§9.6 Transients and surges in the vehicular environment (ISO 7637-2)
N/A
§7.2 Reference to clauses EN 301 489-1§9.8 Surges (EN 61000-4-5) Compliant
§7.2 Reference to clauses EN 301 489-1§9.7 Voltage dips and interruptions (EN 61000-4-11) Compliant
Note: N/A—This EUT is a portbable equipment, there is no telecommunication port, so don’t need this items. Refer to EN 301 4890-1, §7.1, §7.2.
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 9 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.1 - CONDUCTED EMISSIONS Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are spectrum analyzer, cable loss, and LISN. Based on NIS 81, The Treatment of Uncertainty in EMC Measurements, the best estimate of the uncertainty of any conducted emissions measurement at Bay Area Compliance Laboratories Corp. is +2.4 dB. EUT Setup The setup of EUT is according with per ETSI EN 301 489-1 V1.7.1 (2007-04) measurement procedure. The specification used was with the ETSI EN 301 489-1 V1.7.1 (2007-04). The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the middle. The spacing between the peripherals was 10 cm. The adapter was connected to a 230 VAC/50 Hz power source.
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 10 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
EMI Test Receiver Setup The EMI test receiver was set to investigate the spectrum from 150 kHz to 30 MHz. During the conducted emission test, the EMI test receiver was set with the following configurations:
Frequency Range IF B/W 150 kHz – 30 MHz 9 kHz
Test Equipment List and Details
Manufacturer Description Model Serial Number Calibration Date
Calibration Due Date
Com-Power L.I.S.N. LI-200 12005 N/A N/A Com-Power L.I.S.N. LI-200 12208 N/A N/A
Rohde & Schwarz EMI Test Receiver ESCS30 DE25330 2007-03-26 2008-03-26Rohde & Schwarz L.I.S.N. ESH2-Z5 892107/021 2007-03-26 2008-03-26
* Com-Power’s LISN were used as the supporting equipment. * Statement of Traceability: Bay Area Compliance Laboratories Corp. attests that all calibrations have been performed in accordance to NVLAP requirements, traceable to the NIST.
Test Procedure During the conducted emission test, the adapter was connected to the outlet of the LISN. Maximizing procedure was performed on the six (6) highest emissions of the EUT. All data was recorded in the Quasi-peak and average detection mode. Test Results Summary According to the recorded data in following table, the EUT complied with the ETSI EN 301 489-1 V1.7.1 (2007-04), with the worst margin reading of:
9.75 dB at 0.410 MHz in the Line 1 conductor mode.
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 11 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Test Data
Environmental Conditions
Temperature: 25 ° C Relative Humidity: 56% ATM Pressure: 100.2 kPa
The testing was performed by Cinderallar Chen on 2007-12-24. Test Mode: Receiving(Looping in turn)
LINE CONDUCTED EMISSIONS EN 301 489-3 Frequency Amplitude Detector Phase Limit Margin
MHz dBµV QP/AV Line 1/Line2 dBµV dB 0.410 47.90 QP Line 1 57.65 9.75 2.680 45.80 QP Line 1 56.00 10.20 0.480 46.00 QP Line 1 56.34 10.34 0.550 45.60 QP Line 1 56.00 10.40 1.305 45.50 QP Line 1 56.00 10.50 0.395 45.70 QP Line 2 57.96 12.26 0.195 51.10 QP Line 2 63.82 12.72 0.325 42.10 QP Line 1 56.00 13.90 0.265 47.10 QP Line 2 61.27 14.17 0.320 44.60 QP Line 2 59.71 15.11 1.245 40.40 QP Line 2 56.00 15.60 2.680 30.10 AV Line 1 46.00 15.90 2.765 39.90 QP Line 2 56.00 16.10 0.410 27.90 AV Line 1 47.65 19.75 0.395 28.20 AV Line 2 47.96 19.76 1.305 25.30 AV Line 1 46.00 20.70 0.480 24.50 AV Line 1 46.34 21.84 0.265 29.40 AV Line 2 51.27 21.87 0.195 31.60 AV Line 2 53.82 22.22 2.765 22.70 AV Line 2 46.00 23.30 0.325 26.10 AV Line 1 49.58 23.48 0.550 21.50 AV Line 1 46.00 24.50 0.320 24.40 AV Line 2 49.71 25.31 1.245 20.10 AV Line 2 46.00 25.90
Plot(s) of Test Data Plot(s) of Test Data is presented hereinafter as reference.
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 12 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 13 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 14 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.1 - RADIATED EMISSIONS Measurement Uncertainty All measurements involve certain levels of uncertainties, especially in field of EMC. The factors contributing to uncertainties are spectrum analyzer, cable loss, antenna factor calibration, antenna directivity, antenna factor variation with height, antenna phase center variation, antenna factor frequency interpolation, measurement distance variation, site imperfections, mismatch (average), and system repeatability. Based on NIS 81, The Treatment of Uncertainty in EMC Measurements, the best estimate of the uncertainty of a radiation emissions measurement at Bay Area Compliance Laboratories Corp. is +4.0 dB. EUT Setup The radiated emission tests were performed in the 3 meters chamber B test site, using the setup accordance with the ETSI EN 301 489-1 V1.7.1 (2007-04). The specification used was the ETSI EN 301 489-1 V1.7.1 (2007-04). The external I/O cables were draped along the test table and formed a bundle 30 to 40 cm long in the middle. The spacing between the peripherals was 10 cm. The adapter was connected to a 230 VAC/50 Hz power source.
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 15 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
EMI Test Receiver Setup The system was investigated from 30 MHz to 1000 MHz. During the radiated emission test, the EMI test receiver was set with the following configurations:
Frequency R B/W V B/W IF B/W 30 MHz-1 GHz 100 kHz 300 kHz 120 kHz
Test Equipment List and Details
Manufacturer Description Model Serial Number Calibration Date
Calibration Due Date
HP Amplifier 8447E 1937A01046 2007-11-15 2008-11-15Rohde & Schwarz EMI Test Receiver ESCI 100224 2007-09-29 2008-09-29
Sunol Sciences Bilog Antenna JB1 A040904-2 2007-08-14 2008-08-14
* Statement of Traceability: Bay Area Compliance Laboratories Corp. attests that all calibrations have been performed in accordance to NVLAP requirements, traceable to the NIST.
Test Procedure During the Radiated emission test, the adapter was connected to the outlet of the LISN. Maximizing procedure was performed on the highest emissions to ensure that the EUT complied with all installation combinations. All data was recorded in the Quasi-peak detection mode. Corrected Amplitude & Margin Calculation The Corrected Amplitude is calculated by adding the Antenna Factor and Cable Loss, and subtracting the Amplifier Gain from the Meter reading. The basic equation is as follows:
Corrected Amplitude = Meter Reading + Antenna Factor + Cable Loss- Amplifier Gain The “Margin” column of the following data tables indicates the degree of compliance with the applicable limit. For example, a margin of 7dB means the emission is 7dB below the limit. The equation for margin calculation is as follows:
Margin = Limit – Corrected Amplitude
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 16 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Test Data
Environmental Conditions
Temperature: 27 ° C Relative Humidity: 52% ATM Pressure: 100.2kPa
The testing was performed by Green Xu on 2007-09-12. Test Mode: Receiving (looping in turn)
Frequency (MHz)
Corrected Amplitude (dBµV/m)
Antenna Height (cm)
Polarity(H/V)
Turntable Position
(deg)
Correction Factor (dB)
Limit (dBµV/m)
Margin(dB)
437.980500 43.7 319.0 H 3.0 -8.4 47.0 3.3* 897.194062 40.1 232.0 V 185.0 3.9 47.0 6.9 48.959188 32.6 106.0 V 1.0 -16.6 40.0 7.4 42.251312 32.0 107.0 V 0.0 -12.9 40.0 8.0 96.867500 31.4 168.0 H 72.0 -16.8 40.0 8.6
104.344375 31.2 170.0 H 78.0 -14.7 40.0 8.8 * Within measurement uncertainty.
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 17 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
EN 61000-3-2-HARMONIC CURRENT EMISSIONS Test Equipment
Manufacturer Description Model Serial Number Calibration Date
Calibration Due Date
EM Test Harmonic/Flicker Analyzer DPA500 303278 2007-11-21 2008-11-21
EM Test AC Source ACS500 303276 2007-11-21 2008-11-21 Test System Setup Test Standard
EN 61000-3-2: 2006 Test Data and Setup Photo Date of test: 9:08 28.Dec 2007
Measurement file name: Harmonics_3_2
Tester: Amanda Wei
Standard used: EN 61000-3-2
Observation time: 150s
Windows width: 10 periods - (EN/IEC 61000-4-7 Edition 2002)
Customer: Shenzhen Gospell Smarthome Electronic Co., Ltd
E. U. T.: 2.4G Wireless Receiver
Mode: GP-708
Test Mode: Receiving
AC Mains
AC Source EUT
Wooden Table
0.8M
Analyzer
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 18 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Average harmonic current results
Hn Ieff [A] Ieff [%] Limit [A] Result 1 8.325E-3 100.000 2 189.220E-6 2.273 1.08 PASS 3 8.239E-3 98.967 2.30 PASS 4 298.098E-6 3.581 430.00E-3 PASS 5 7.970E-3 95.731 1.14 PASS 6 271.599E-6 3.262 300.00E-3 PASS 7 7.609E-3 91.406 770.00E-3 PASS 8 274.086E-6 3.292 230.00E-3 PASS 9 7.146E-3 85.839 400.00E-3 PASS
10 248.966E-6 2.991 184.00E-3 PASS 11 6.595E-3 79.222 330.00E-3 PASS 12 180.653E-6 2.170 153.33E-3 PASS 13 5.972E-3 71.731 210.00E-3 PASS 14 165.494E-6 1.988 131.43E-3 PASS 15 5.303E-3 63.705 150.00E-3 PASS 16 123.745E-6 1.486 115.00E-3 PASS 17 4.602E-3 55.286 132.35E-3 PASS 18 130.884E-6 1.572 102.22E-3 PASS 19 3.910E-3 46.968 118.42E-3 PASS 20 105.711E-6 1.270 92.00E-3 PASS 21 3.231E-3 38.813 160.71E-3 PASS 22 121.383E-6 1.458 83.64E-3 PASS 23 2.585E-3 31.056 146.74E-3 PASS 24 118.326E-6 1.421 76.66E-3 PASS 25 2.003E-3 24.065 135.00E-3 PASS 26 127.407E-6 1.530 70.77E-3 PASS 27 1.474E-3 17.702 124.99E-3 PASS 28 144.427E-6 1.735 65.71E-3 PASS 29 1.052E-3 12.639 116.39E-3 PASS 30 133.757E-6 1.607 61.33E-3 PASS 31 762.475E-6 9.159 108.87E-3 PASS 32 247.030E-6 2.967 57.50E-3 PASS 33 623.918E-6 7.495 102.27E-3 PASS 34 129.930E-6 1.561 54.12E-3 PASS 35 614.390E-6 7.380 96.44E-3 PASS 36 123.809E-6 1.487 51.11E-3 PASS 37 659.021E-6 7.916 91.21E-3 PASS 38 114.108E-6 1.371 48.42E-3 PASS 39 711.871E-6 8.551 86.53E-3 PASS 40 115.663E-6 1.389 46.00E-3 PASS
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 19 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Maximum harmonic current results
Hn Ieff [A] Ieff [%] Limit [A] Result 1 8.743E-3 100.000 2 330.453E-6 3.779 1.62 PASS 3 8.514E-3 97.378 3.45 PASS 4 451.405E-6 5.163 645.00E-3 PASS 5 8.134E-3 93.025 1.71 PASS 6 403.643E-6 4.617 450.00E-3 PASS 7 7.788E-3 89.078 1.15 PASS 8 386.025E-6 4.415 345.00E-3 PASS 9 7.365E-3 84.238 600.00E-3 PASS
10 356.246E-6 4.074 276.00E-3 PASS 11 6.753E-3 77.237 495.00E-3 PASS 12 259.594E-6 2.969 229.99E-3 PASS 13 6.109E-3 69.871 315.00E-3 PASS 14 260.228E-6 2.976 197.15E-3 PASS 15 5.414E-3 61.919 225.00E-3 PASS 16 180.814E-6 2.068 172.50E-3 PASS 17 4.706E-3 53.822 198.52E-3 PASS 18 206.977E-6 2.367 153.33E-3 PASS 19 4.011E-3 45.878 177.63E-3 PASS 20 174.571E-6 1.997 138.00E-3 PASS 21 3.375E-3 38.599 160.71E-3 PASS 22 186.879E-6 2.137 125.46E-3 PASS 23 2.701E-3 30.893 146.74E-3 PASS 24 221.924E-6 2.538 114.99E-3 PASS 25 2.094E-3 23.955 135.00E-3 PASS 26 231.403E-6 2.647 106.16E-3 PASS 27 1.564E-3 17.884 124.99E-3 PASS 28 279.268E-6 3.194 98.57E-3 PASS 29 1.157E-3 13.228 116.39E-3 PASS 30 254.261E-6 2.908 92.00E-3 PASS 31 906.331E-6 10.366 108.87E-3 PASS 32 1.001E-3 11.448 86.25E-3 PASS 33 756.107E-6 8.648 102.27E-3 PASS 34 225.977E-6 2.585 81.18E-3 PASS 35 691.231E-6 7.906 96.44E-3 PASS 36 186.340E-6 2.131 76.66E-3 PASS 37 736.554E-6 8.424 91.21E-3 PASS 38 177.328E-6 2.028 72.63E-3 PASS 39 788.006E-6 9.013 86.53E-3 PASS 40 209.989E-6 2.402 69.00E-3 PASS
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 20 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Maximum harmonic voltage results
Hn Ueff [V] Ueff [%] Limit [%] Result 1 231.47 100.640 2 77.69E-3 0.034 0.2 PASS 3 125.45E-3 0.055 0.9 PASS 4 13.15E-3 0.006 0.2 PASS 5 28.24E-3 0.012 0.4 PASS 6 12.78E-3 0.006 0.2 PASS 7 24.39E-3 0.011 0.3 PASS 8 13.54E-3 0.006 0.2 PASS 9 46.35E-3 0.020 0.2 PASS
10 21.01E-3 0.009 0.2 PASS 11 25.36E-3 0.011 0.1 PASS 12 16.05E-3 0.007 0.1 PASS 13 42.16E-3 0.018 0.1 PASS 14 12.76E-3 0.006 0.1 PASS 15 23.95E-3 0.010 0.1 PASS 16 11.58E-3 0.005 0.1 PASS 17 43.86E-3 0.019 0.1 PASS 18 13.93E-3 0.006 0.1 PASS 19 38.73E-3 0.017 0.1 PASS 20 16.84E-3 0.007 0.1 PASS 21 22.27E-3 0.010 0.1 PASS 22 17.92E-3 0.008 0.1 PASS 23 33.76E-3 0.015 0.1 PASS 24 12.60E-3 0.005 0.1 PASS 25 32.92E-3 0.014 0.1 PASS 26 16.85E-3 0.007 0.1 PASS 27 38.43E-3 0.017 0.1 PASS 28 12.41E-3 0.005 0.1 PASS 29 18.17E-3 0.008 0.1 PASS 30 15.29E-3 0.007 0.1 PASS 31 21.40E-3 0.009 0.1 PASS 32 13.72E-3 0.006 0.1 PASS 33 27.89E-3 0.012 0.1 PASS 34 16.59E-3 0.007 0.1 PASS 35 26.88E-3 0.012 0.1 PASS 36 14.85E-3 0.006 0.1 PASS 37 21.80E-3 0.009 0.1 PASS 38 14.41E-3 0.006 0.1 PASS 39 23.72E-3 0.010 0.1 PASS 40 11.40E-3 0.005 0.1 PASS
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 21 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 22 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
EN 61000-3-3- VOLTAGE FLUCTUATION AND FLICKER Test Equipment
Manufacturer Description Model Serial Number Calibration Date
Calibration Due Date
EM Test Harmonic/Flicker Analyzer DPA500 303278 2007-11-21 2008-11-21
EM Test AC Source ACS500 303276 2007-11-21 2008-11-21 Test System Setup Test Standard
EN 61000-3-3: 1995+A1: 2001+A2: 2005
AC Mains
AC Source EUT
Wooden Table
0.8M
Analyzer
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 23 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Test Data and Setup Photo Date of test: 22:41 18.Dec 2007
Tester: Amanda Wei
Standard used: EN 61000-3-3 Flicker
Short time (Pst): 10 min
Observation time: 10 min (1 Flicker measurement)
Flickermeter: 230V / 50Hz
Customer: Shenzhen Gospell Smarthome Electronic Co., Ltd
E. U. T.: 2.4G Wireless Receiver
Model: GP-708
Test Mode: Receiving
MMaaxxiimmuumm FFlliicckkeerr rreessuullttss EUT values Limit Result Pst 0.028 1.00 PASS Plt 0.028 0.65 PASS dc [%] 0.005 3.30 PASS dmax [%] 0.093 4.00 PASS dt [s] 0.000 0.50 PASS
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 24 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.2 RF ELECTROMAGNETIC FIELD (80 MHz -1000 MHz and 1400 MHz –2000 MHz) Test Equipment
Manufacturer Description Model Serial Number Calibration Date
Calibration Due Date
Amplifier Research Amplifier 150W1000 302657 2007-11-15 2008-11-15Amplifier Research Field Meter FM5004 302149 2007-11-01 2008-11-01Amplifier Research Sensor FP5000 301825 2007-05-31 2008-05-31
HP Signal Generator HP8657A 2849U00982 2007-09-29 2008-09-29Sunol Sciences Broadband Antenna JB1 A040904-1 2007-08-14 2008-08-14
Giga-tronics Signal Generator 1026 270801 2007-09-29 2008-09-29Sunol Sciences Horn Antenna DRH-118 A052604 2007-09-25 2008-09-25
* Statement of Traceability: Bay Area Compliance Laboratories Corp.(Shenzhen) attests that all calibrations have been performed in accordance to NVLAP requirements, traceable to the NIST. Test System Setup Wooden table
3MetersEUT
System
0.8 Meter
Anechoic Chamber
Power Amp Signal Generator
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 25 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Test Standard
ETSI EN 301 489-1 V1.7.1 (2007-04) / EN 61000-4-3: 2006 Test level 2 at 3V / m
Test level
Level Field Strength V/m
1. 1 2. 3 3. 10 X. Special
Performance criterion: A
Test Procedure
The EUT and its simulators are placed on a turn table which is 0.8 meter above the ground. The EUT is set 3 meters away from the transmitting antenna which is mounted on an antenna tower. Both horizontal and vertical polarization of the antenna are set on test. Each of the four sides of EUT must be faced this transmitting antenna and measured individually. In order to judge the EUT performance, a CCD camera is used to monitor the EUT. All the scanning conditions are as follows:
Condition of Test Remarks ---------------------------------------------- ----------------------------------
1. Field Strength 3 V/m (Test level 2) 2. Radiated Signal Modulated AM 1 kHz 80% Modulation 3. Scanning Frequency 80 – 1000 MHz and 1400-2000 MHz 4. Sweeping time of radiated 0.0015decade/s 5. Dwell Time 1Sec.
Test Data and Setup Photo
Environmental Conditions
Temperature: 25° C Relative Humidity: 56 % ATM Pressure: 100.2 kPa
The testing was performed by Amanda Wei on 2008-01-03. Test Mode: Receiving
Front (3 V/m) Rear (3 V/m) Left Side (3 V/m) Right Side (3 V/m) Frequency
Range (MHz) VERT HORI VERT HORI VERT HORI VERT HORI
80-1000 A A A A A A A A
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 26 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 27 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.2 ELECTROSTATIC DISCHARGE Test Equipment
Manufacturer Description Model Serial Number Calibration Date
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 28 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Test Procedure
Air Discharge:
This test is done on a non-conductive surfaces. The round discharge tip of the discharge electrode shall be approached as fast as possible to touch the EUT. After each discharge, the discharge electrode shall be removed from the EUT. The generator is then re-triggered for a new single discharge and repeated 10 times for each pre-selected test point. This procedure shall be repeated until all the air discharge completed. Contact Discharge:
All the procedure shall be same as Section 8.3.1 of EN 61000-4-2, except that the tip of the discharge electrode shall touch the EUT before the discharge switch is operated. Indirect discharge for horizontal coupling plane
At least 20 single discharges shall be applied to the horizontal coupling plane, at points on each side of the EUT. The discharge electrode positions vertically at a distance of 0.1 m from the EUT and with the discharge electrode touching the coupling plane. Indirect discharge for vertical coupling plane
At least 20 single discharge shall be applied to the center of one vertical edge of the coupling plane. The coupling plane, of dimensions 0.5m X 0.5m, is placed parallel to, and positioned at a distance of 0.1m from the EUT. Discharges shall be applied to the coupling plane, with this plane in sufficient different positions that the four faces of the EUT are completely illuminated.
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 29 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Test Data and Setup Photo
Environmental Conditions
Temperature: 25 ° C Relative Humidity: 58 % ATM Pressure: 100.0 kPa
The testing was performed by Amanda Wei on 2007-12-28. Test Mode: Receiving Table 1: Electrostatic Discharge Immunity (Air Discharge)
Test Levels (kV) EN 61000-4-2
Test Points -2 +2 -4 +4 -6 +6 -8 +8 -15 +15
/ / / / / / / / / / / Table 2: Electrostatic Discharge Immunity (Direct Contact)
Test Levels (kV) EN 61000-4-2
Test Points -2 +2 -4 +4 -6 +6 -8 +8 -15 +15
Screw 12 Points A A A A / / / / / / Surface 5 Points A A A A / / / / / /
Table 3: Electrostatic Discharge Immunity (Indirect Contact HCP)
Test Levels (kV) EN 61000-4-2
Test Points -2 +2 -4 +4 -6 +6 -8 +8 -15 +15
Front Side A A A A / / / / / / Back Side A A A A / / / / / / Left Side A A A A / / / / / / Right Side A A A A / / / / / /
Table 4: Electrostatic Discharge Immunity (Indirect Contact VCP)
Test Levels (kV) EN 61000-4-2 Test Points -2 +2 -4 +4 -6 +6 -8 +8 -15 +15
Front Side A A A A / / / / / / Back Side A A A A / / / / / / Left Side A A A A / / / / / / Right Side A A A A / / / / / /
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 30 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Air Discharge: Indirect Contact:
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 31 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.2- IMMUNITY: FAST TRANSIENTS COMMON MODE Test Equipment
Manufacturer Description Model Serial Number Calibration Date
Calibration Due Date
EM Test Ultra Compact Generator UCS500-M 303279 2007-03-01 2008-03-01
EM Test Auto-transformer MV2616 0403-16 2007-09-29 2008-09-29
Test System Setup Test Standard
ETSI EN 301 489-1 V1.7.1 (2007-04) / EN 61000-4-4: 2004 Test level 2 at 1 kV
Test Level
Open Circuit Output Test Voltage ±10% Level On Power Supply Lines On I/O (Input/Output)
Signal data and control lines 1 0.5 kV 0.25 kV 2 1 kV 0.5 kV 3 2 kV 1 kV 4 4 kV 2 kV X Special Special
Performance criterion: B
EUT
Ground Plane
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 32 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Test Procedure The EUT was arranged for Power Line Coupling and for I/O Line Coupling through a capacitive clamp, where applicable. (Note: The I/O coupling test using a capacitive clamp is performed on the I/O interface cables that are longer in length than 3 meters.) A metal ground plane 2.4 meter by 2.0 meter was placed between the floor and the table and is connected to the earth by a 2.0 meter ground rod. The ground rod is connected to the test facility’s electrical earth. Test Data and Setup Photo
Environmental Conditions
Temperature: 25 ° C Relative Humidity: 58 % ATM Pressure: 100.0 kPa
The testing was performed by Amanda Wei on 2007-12-28. Test Mode: Receiving
Test Levels (kV) EN 61000-4-4
Test Points +0. 5 -0. 5 +1.0 -1.0 +2.0 -2.0 +4.0 -4.0L1 A A A A / / / /
L2 A A A A / / / /
Earth / / / / / / / /
L1+L2 A A A A / / / /
L1 + Earth / / / / / / / /
L2 + Earth / / / / / / / /
Power Supply
Power Line of EUT
L1+L2+Earth / / / / / / / /
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 33 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.2- IMMUNITY: RF COMMON MODE 0.15 MHz To 80 MHz Test Equipment
Manufacturer Description Model Serial Number Calibration Date
Calibration Due Date
EM CDN M3 303288 2007-03-01 2008-03-01EM Test C/S Tester CWS500 303277 2007-03-01 2008-03-01EM Test Attenuator 6dB 303282 2007-03-01 2008-03-01EM Test Attenuator 6dB 303283 N/A N/A
FCC Bulk Current Injection Probe F-120-9A 303284 2007-03-01 2008-03-01
* Statement of Traceability: Bay Area Compliance Laboratories Corp. attested that all calibrations have been performed in accordance to NVLAP requirements, traceable to the NIST. Test Setup 0.1m Test Standard
ETSI EN 301 489-1 V1.7.1 (2007-04) / EN 61000-4-6: 2006 Test level 2 at 3 V (r.m.s.), 0.15 MHz ~ 80 MHz,
Test Level
Level Voltage Level (r.m.s.) (V)
1 1 2 3 3 10 X Special
Performance criterion: A
Wooden TableSG
CDNEUT
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 34 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Test Procedure
1) Let the EUT work in test mode and test it. 2) The EUT are placed on an insulating support 0.1 m high above a ground reference plane. CDN (coupling and decoupling device) is placed on the ground plane about 0.3 m from EUT. Cables between CDN and EUT are as short as possible, and their height above the ground reference plane shall be between 30 and 50 mm (where possible). 3) The disturbance signal described below is injected to EUT through CDN. 4) The EUT operates within its operational mode(s) under intended climatic conditions after power on. 5) The frequency range is swept from 150 kHz to 80 MHz using 3V signal level, and with the disturbance signal 80% amplitude modulated with a 1KHz sine wave. 6) The rate of sweep shall not exceed 1.5*10-3decades/s. Where the frequency is swept incrementally, the step size shall not exceed 1% of the start and thereafter 1% of the preceding frequency value. 7) Recording the EUT operating situation during compliance testing and decide the EUT immunity criterion.
Test Data and Setup Photo
Environmental Conditions
Temperature: 25 ° C Relative Humidity: 58 % ATM Pressure: 100.0 kPa
The testing was performed by Amanda Wei on 2007-12-28. Test Mode: Receiving Test Ports: Power Supply (AC 230 V/50 Hz) Modulation: Amplitude 80%, 1 kHz sinewave Test level: 3V r.m.s.
Level Voltage Level (r.m.s.) U0 Pass Fail
1 1 / / 2 3 A / 3 10 / / X Special / /
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 35 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 36 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.2- IMMUNITY: SURGES, LINE TO LINE AND LINE TO GROUND Test Equipment
Manufacturer Description Model Serial Number Calibration Date
Calibration Due Date
EM Test Ultra Compact Generator UCS500-M 303279 2007-03-01 2008-03-01
EM Test Auto-transformer MV2616 0403-16 2007-09-29 2008-09-29
Test System Setup Test Standard
ETSI EN 301 489-1 V1.7.1 (2007-04) / EN 61000-4-5: 2006 L-N: Test level 2 at 1 kV
Test Level
Open Circuit Output Test Voltage ±10% Level On Power Supply Lines On I/O (Input/Output)
Signal data and control lines 1 0.5 kV 0.25 kV 2 1 kV 0.5 kV 3 2 kV 1 kV 4 4 kV 2 kV X Special Special
Performance criterion: B
EUT
Ground Plane
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 37 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Test Procedure
1) For line to line coupling mode, provide a 0.5 kV 1.2/50us voltage surge (at open-circuit
condition). 2) At least 5 positive and 5 negative (polarity) tests with a maximum 1/min repetition rate are
conducted during test. 3) Different phase angles are done individually. 4) Record the EUT operating situation during compliance test and decide the EUT immunity
criterion for above each test. Test Data and Setup Photo
Environmental Conditions
Temperature: 25 ° C Relative Humidity: 56 % ATM Pressure: 100.0 kPa
The testing was performed by Cinderallar Chen on 2007-12-28. Test Mode: Receiving
Table 1: Surge Power Supply
Level Voltage Poll Path Pass Fail
1 0.5 kV ± L-N A / 2 1 kV ± L-N A / 3 2 kV ± L-N, L-PE, N-PE / / 4 4 kV ± L-N, L-PE, N-PE / /
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 38 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
ETSI EN 301 489-3 V1.4.1 (2002-08) §7.2- IMMUNITY: VOLTAGE DIPS AND INTERRUPTIONS Test Equipment
Manufacturer Description Model Serial Number
Calibration Date
Calibration Due Date
EM Test Ultra Compact Generator UCS500-M 303279 2007-03-01 2008-03-01EM Test Auto-transformer MV2616 0403-16 2007-09-29 2008-09-29
Test Setup Test Standard
ETSI EN 301 489-1 V1.7.1 (2007-04) / EN 61000-4-11: 2004 Test levels and Performance Criterion
Test Level
Test Level Voltage dip and short interruptions(%UT)
Duration Time (ms)
1 0 10
2 0 20
3 70 100
4 0 5000
Performance criterion: C & B
EUT
Ground Plane
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 39 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Test Procedure
1) The interruption is introduced at selected phase angles with specified duration. 2) Record any degradation of performance.
Test Data and Setup Photo
Environmental Conditions
Temperature: 25° C Relative Humidity: 58% ATM Pressure: 100.0kPa
The testing was performed by Cinderallar Chen on 2007-12-20. Test Mode: Receiving
Voltage Tips/Interruptions Test
Level U2 (% Reduction)
Duration Time (ms)
Phase Angle N Pass Fail
1 0 10 0/90/180/270 3 A /
2 0 20 0/90/180/270 3 A /
3 70 100 0/90/180/270 3 B /
4 0 5000 0/90/180/270 3 C /
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 40 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
EXHIBIT A- EUT PHOTOGRAPHS EUT - Front View EUT - Rear View
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 41 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
EUT – Side View EUT – Port View
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 42 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
EUT – Uncovered View EUT – Main Board View
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 43 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
EUT – Main Board Component View EUT – Main Board Circuit View
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 44 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
EUT – RF Board Top View EUT – RF Board Bottom View
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 45 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
EXHIBIT B- TEST SETUP PHOTOGRAPHS Conducted Emissions - Front View Conducted Emissions - Side View
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 46 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
Radiated Emissions – Front View (Below 1GHz) Radiated Emissions – Rear View (Below 1GHz)
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 47 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
EXHIBIT C- BLOCK DIAGRAM/SCHEMATICS Not Available at Time of Test
Shenzhen Gospell Smarthome Electronic Co., Ltd Model: GP-708
Report # RSZ07121302-2 Page 48 of 48 ETSI EN 301 489-3 V1.4.1 (2002-08) Report
EXHIBIT D- USERS MANUAL
Not Available at Time of Test