ETSI EN301 489 EMC TEST REPORT Report Reference No. ...................... : 18EEAB10012 41 Date Sample(s) Received ................ : 2018-10-30 Date Tested...................................... : From 2018-10-30 to 2018-11-15 Date of issue .................................... : 2018-11-21 Testing Laboratory ........................... : DongGuan ShuoXin Electronic Technology Co., Ltd. Address ............................................ : Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Applicant’s name .............................. : EMC Healthcare Co., Ltd. Address ............................................ : NGA Kioicho Building 6F, 3-29 Kioicho, Chiyoda-ku, Tokyo, Japan Manufacturer .................................... : Jiangmen Benlida Printed Circuit Co.,Ltd. Test specification: Test item description ........................ : CALM. Module Trade Mark ....................................... : -- Model/Type reference .................... : SVN-840C Ratings ............................................. : I/P: DC 5V Responsible Engineer : Smile Wang Authorized Signatory: King Wang

ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

ETSI EN301 489 EMC TEST REPORT

Report Reference No. ...................... : 18EEAB10012 41

Date Sample(s) Received ................ : 2018-10-30

Date Tested ...................................... : From 2018-10-30 to 2018-11-15

Date of issue .................................... : 2018-11-21

Testing Laboratory ........................... : DongGuan ShuoXin Electronic Technology Co., Ltd.

Address ............................................ : Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn

District, ChangAn Town, DongGuan City, GuangDong,

China

Applicant’s name .............................. : EMC Healthcare Co., Ltd.

Address ............................................ : NGA Kioicho Building 6F, 3-29 Kioicho, Chiyoda-ku, Tokyo,

Japan

Manufacturer .................................... : Jiangmen Benlida Printed Circuit Co.,Ltd.

Test specification:

Test item description ........................ : CALM. Module

Trade Mark ....................................... : --

Model/Type reference .................... : SVN-840C

Ratings ............................................. : I/P: DC 5V

Responsible Engineer :

Smile Wang

Authorized Signatory:

King Wang

Page 2: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAB10012 41 1 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

TABLE OF CONTENTS

TEST REPORT DECLARE ............................................................................................................. 3

1.Summary of test results ............................................................................................................... 4

2. General test information ............................................................................................................. 5

2.1 Description of EUT ................................................................................................................... 5

2.2 Accessories of EUT .................................................................................................................. 5

2.3 Assistant equipment used for test ............................................................................................. 5

2.4Block diagram EUT configuration for test .................................................................................. 6

2.5Measurement uncertainty .......................................................................................................... 6

3.1 Test equipment ......................................................................................................................... 7

3.2 Block diagram of test setup ...................................................................................................... 7

3.3 Radiated disturbance limit of class B ........................................................................................ 8

3.4 Test Procedure ......................................................................................................................... 9

3.5 Test result ................................................................................................................................. 9

4 Conducted Emission .................................................................................................................. 14

4.1 Conducted Emission Measurement ........................................................................................ 14

4.2 Power Line Conducted Emission ............................................................................................ 14

4.3 Measurement instruments List ................................................................................................ 14

4.4 Test Procedure ....................................................................................................................... 15

4.5 Deviation From Test Standard ................................................................................................ 15

4.6 Test Setup .............................................................................................................................. 15

4.7 EUT Operating Conditions ...................................................................................................... 15

4.8 Test Results ............................................................................................................................ 16

5 Voltage Fluctuation And Flicks Measurement ............................................................................ 18

5.1 Limits of Voltage Flucturtion And Flicks Measurement ........................................................... 18

5.2 Measurement Instruments List ............................................................................................... 18

5.3 Test Procedure ....................................................................................................................... 18

5.4 Deviation From Test Standard ................................................................................................ 18

5.5 Test Setup .............................................................................................................................. 19

5.6 EUT Operting Conditions ........................................................................................................ 19

5.7 Test Results ............................................................................................................................ 20

6 Electrostatic discharge (ESD) .................................................................................................... 21

6.1Test equipment ........................................................................................................................ 21

6.2 Block diagram of test setup .................................................................................................... 21

6.3 Test levels and performance criterion ..................................................................................... 21

6.4 Test Procedure ....................................................................................................................... 22

Page 3: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAB10012 41 2 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

6.5 Test result ............................................................................................................................... 23

7 Continuous radio frequency disturbances .................................................................................. 24

7.1 Test equipment ....................................................................................................................... 24

7.2 Block diagram of test setup .................................................................................................... 24

7.3 Test levels and performance criterion ..................................................................................... 25

7.4 Test Procedure ....................................................................................................................... 25

7.5 Test result ............................................................................................................................... 26

Page 4: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 3 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

TEST REPORT DECLARE

Test Standard Used:

ETSI EN301 489-1 V2.1.1(2017-02); ETSI EN301 489-17 V3.1.1(2017-02)

We Declare: The equipment described above is tested by DongGuan ShuoXin Electronic Technology Co., Ltd. and in

the configuration tested the equipment complied with the standards specified above. The test results are

contained in this test report and DongGuan ShuoXin Electronic Technology Co., Ltd. is assumed of full

responsibility for the accuracy and completeness of these tests.

After test and evaluation, our opinion is that the equipment in accordance with above standards about the electromagnetic compatibility requirements of Article 3.1(b) of the RE Directive

Report No: 18EEAB10012 41

Date of Test: 2018-10-30---2018-11-15 Date of Report: 2018-11-25

Note: This report applies to above tested sample only. This report shall not be reproduced in parts

without written approval of DongGuan ShuoXin Electronic Technology Co., Ltd.

Applicant : Eagle Matrix Co., Ltd.

Address : NGA Kioicho Building 6F, 3-29 Kioicho, Chiyoda-ku, Tokyo, Japan

Equipment under Test : CALM. Module

Model No : SVN-840C

Manufacturer : Jiangmen Benlida Printed Circuit Co.,Ltd.

Address : No.76, Longxi Road, Jianhai District, Jiangmen City, Guangdong Province. P.R. China

Page 5: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 4 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

1. Summary of test results

Description of Test Item According Standard Results

EMC emission

Radiated emission EN 301489-1 V2.2.0 §8.2 PASS

Conducted emission(AC mains port) EN 301489-1 V2.2.0 §8.4 PASS

Harmonic Current Emission EN 301489-1 V2.2.0 §8.5 N/A

Voltage Fluctuations & Flicker EN 301489-1 V2.2.0 §8.6 PASS

Immunity

RF electromagnetic field

(80MHz to 6GHz) EN 301489-1 V3.2.0 §9.2 PASS

Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS

Fast transients EN 301489-1 V3.2.0 §9.4 PASS

Surges EN 301489-1 V3.2.0 §9.8 PASS

Injected Current EN 301489-1 V3.2.0 §9.5 PASS

Volt. Interruptions Volt. Dips EN 301489-1 V3.2.0 §9.7 PASS

N/A is an abbreviation for Not Applicable.

Page 6: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 5 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

2. General test information

2.1 Description of EUT

EUT* Name : CALM. Module

Model Number : SVN-840C

Trade Mark : --

EUT function description : Please reference user manual of this device

Power supply : DC 5V

Sample Type : Series production

Note1: EUT is abbreviation of equipment under test. Note2: This test report only for EMC performance of wireless function of device, and for all other

non-wireless functions EMC performance was tested and reported in another EMC test report.

2.2 Accessories of EUT

Description of Accessories

Manufacturer Model number or Type Other

/ / / /

2.3 Assistant equipment used for test

Description of

Assistant equipment

Manufacturer Model number or

Type EMC

Compliance SN

NOTEBOOK ASUS / / /

NO. Name Cable length (m) Shielded(Y/N) Comments

Note: “Y” represents shielded.

“N” represents unshielded.

Page 7: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 6 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

2.4Block diagram EUT configuration for test

AE EUT

Note1: According exploration test, the volume of EUT was set hopping to get worst EMC performance. so all the final tests were performed hopping Mode.

2.5Measurement uncertainty

Test Item Uncertainty

Uncertainty for Conduction emission test 3.4dB

Uncertainty for Radiation Emission test (30MHz-200MHz)

4.6 dB (Polarize: V)

4.6 dB (Polarize: H)

Uncertainty for Radiation Emission test (200MHz-1GHz)

6.10 dB (Polarize: V)

5.08 dB (Polarize: H)

Uncertainty for Radiation Emission test (1GHz to 25GHz)

5.12dB (Polarize: V)

5.12 dB (Polarize: H)

Note:This uncertainty represents an expanded uncertainty expressed at approximately the 95%

confidence level using a coverage factor of k=2.

Page 8: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 7 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

3 Radiated emissions test

3.1 Test equipment

Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated until

1 Log-Bicon Antenna SCHWARZBECK VULB9168 VULB9168-192 12/17/2018

2 Pre-Amplifier HP 8447F 3113A05680 12/17/2018

3 EMI Test Receiver R&S ESCI 101307 12/17/2018

4 Spectrum Analyzer Agilent E4407B US40240708 07/03/2019

5 Horn Antenna Schwarzbeck BBHA 9120DBBHA 9120D

1065 12/17/2018

6 Pre-Amplifier CY EMC011830 980136 12/17/2018

7 Turn Table UC UC3000 N/A N/A

8 Antenna Mast UC UC3000 N/A N/A

9 Software Farad EZ-EMC Ver. ATT-03A N/A

3.2 Block diagram of test setup

Below 1GHz

Page 9: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 8 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

Above 1GHz

3.3 Radiated disturbance limit of class B

Frequency Field Strengths Limits at 10m

measuring distance dB(V)/m

Field Strengths Limits at 3m measuring distance

dB(V)/m 30MHz to 230MHz 30 40

230MHz to 1000MHz 37 47 1GHz to 3GHz / Average:50 ; Peak:70 3GHz to 6GHz / Average:54 ; Peak:74

Note: (1) The smaller limit shall apply at the cross point between two frequency bands.

(2) Distance is the distance in meters between the measuring instrument, antenna and the closest point

of any part of the device or system.

(3) According EN55022:2010 clause 10.3.1, if the field-strength measurement at 10 m cannot be made

because of high ambient noise levels, or for other reasons, measurement of class B EUT’s may be

made at a closer distance, for example 3 m. An inverse proportionality factor of 20 dB per decade

should be used to normalize the measured data to specified distance for determining compliance.

Page 10: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 9 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

3.4 Test Procedure

(1) The EUT was placed on a non-metallic table, 80 cm above the ground plane inside an semi-anechoic

chamber.

(2) Setup EUT and simulator as shown in section 2.4 and 4.2

(3) Test antenna was located 3m (see note) from the EUT on an adjustable mast. A pre-scan was first

performed in order to find prominent radiated emissions. For final emissions measurements at each

frequency of interest, the EUT were rotated and the antenna height was varied between 1m and 4m in

order to maximize the emission. Measurements in both horizontal and vertical polarities were made

and the data was recorded. In order to find the maximum emission, the relative positions of

equipments and all of the interface cables were changed according to EN55022:2010 on radiated

emission test.

(4) Spectrum frequency from 30MHz to 6GHz was investigated.

(5) For final emissions measurements at each frequency of interest, the EUT were rotated and the

antenna height was varied between 1m and 4m in order to maximize the emission. Measurements in

both horizontal and vertical polarities were made and the data was recorded. In order to find the

maximum emission, the relative positions of equipments and all of the interface cables were changed

according to EN55022:2010 on Radiated Emission test.

(6) For emissions from 30MHz to 1GHz, Quasi-Peak values were measured with EMI Receiver and the

bandwidth of Receiver is 120 KHz.

(7) For emissions above 1GHz, both Peak and Average level were measured with Spectrum Analyzer,

and the RBW is set at 1MHz VBW is set at 3MHz.

3.5 Test result

PASS. (See below detailed test result)

Note1: All emissions not reported below are too low against the prescribed limits.

Note2: Radiated emissions test is not applicable for ancillary equipment incorporated in the radio equipment,

or for ancillary equipment intended to be measured in combination with the radio equipment and radio

equipment. In these cases the requirements of the relevant product standard for the effective use of

the radio spectrum shall apply, so for this test the wireless function of EUT was turn off.

Page 11: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 10 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

Radiated Emission Test Result(Below 1G)

EUT: CALM. Module Model No.: SVN-840C Temperature: 24   Relative Humidity: 55% Distance: 3m Test Power: DC 5V Polarization: Horizontal Test Result: Pass Test Time: 2018-11-12 Test By: Standard: (RE)CISPR32 class B 3m Test Mode: TX Note:

No. Frequency Reading Correct Result Limit Margin Remark

(MHz) (dBuV/m) Factor(dB/m) (dBuV/m) (dBuV/m) (dB) 1 31.0705 43.94 -13.92 30.02 40.00 -9.98 QP 2 52.2079 49.87 -15.72 34.15 40.00 -5.85 QP 3 119.8555 45.29 -14.67 30.62 40.00 -9.38 QP 4 204.2376 36.85 -10.40 26.45 40.00 -13.55 QP 5 216.0240 35.52 -9.91 25.61 40.00 -14.39 QP 6 468.8761 47.56 -7.56 40.00 47.00 -7.00 QP

Page 12: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 11 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

EUT: CALM. Module Model No.: SVN-840C Temperature: 24   Relative Humidity: 55% Distance: 3m Test Power: DC 5V Polarization: Vertical Test Result: Pass Test Time: 2018-11-12 Test By: Standard: (RE)CISPR32 class B 3m Test Mode: TX Note: 2402

No. Frequency Reading Correct Result Limit Margin Remark

(MHz) (dBuV/m) Factor(dB/m) (dBuV/m) (dBuV/m) (dB)

1 33.6802 33.97 -13.31 20.66 40.00 -19.34 QP 2 39.1615 41.86 -13.38 28.48 40.00 -11.52 QP 3 44.5867 47.33 -14.30 33.03 40.00 -6.97 QP 4 47.9939 48.86 -13.85 35.01 40.00 -4.99 QP 5 50.9420 48.64 -13.40 35.24 40.00 -4.76 QP 6 216.0240 38.09 -11.11 26.98 40.00 -13.02 QP

Page 13: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 12 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

Radiated Emission Test Result(Above 1G)

EUT: CALM. Module Model No.: SVN-840C Temperature: 24   Relative Humidity: 55% Distance: 3m Test Power: DC 5V Polarization: Vertical Test Result: Pass Test Time: 2018-11-12 Test By: Standard: (RE)EN55032_Class B_3m 1-6G Peak Test Mode: TX Note:

No. Frequency Reading Correct Result Limit Margin Remark

(MHz) (dBuV/m) Factor(dB/m) (dBuV/m) (dBuV/m) (dB) 1 2450.000 52.73 -16.59 36.14 70.00 -33.86 peak 2 2450.000 36.72 -16.59 20.13 50.00 -29.87 AVG 3 2987.500 52.80 -14.46 38.34 70.00 -31.66 peak 4 2987.500 36.52 -14.46 22.06 50.00 -27.94 AVG 5 3787.500 51.23 -12.71 38.52 74.00 -35.48 peak 6 3787.500 36.05 -12.71 23.34 54.00 -30.66 AVG 7 4925.000 49.63 -10.23 39.40 74.00 -34.60 peak 8 4925.000 31.40 -10.23 21.17 54.00 -32.83 AVG 9 5550.000 49.52 -8.16 41.36 74.00 -32.64 peak

10 5550.000 31.46 -8.16 23.30 54.00 -30.70 AVG 11 5987.500 49.34 -7.89 41.45 74.00 -32.55 peak 12 5987.500 33.48 -7.89 25.59 54.00 -28.41 AVG

Page 14: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 13 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

EUT: CALM. Module Model No.: SVN-840C Temperature: 24   Relative Humidity: 55% Distance: 3m Test Power: DC 5V Polarization: Horizontal Test Result: Pass Test Time: 2018-11-12 Test By: Standard: (RE)EN55032_Class B_3m 1-6G Peak Test Mode: TX Note:

No. Frequency Reading Correct Result Limit Margin Remark

(MHz) (dBuV/m) Factor(dB/m) (dBuV/m) (dBuV/m) (dB) 1 2187.500 51.60 -17.42 34.18 70.00 -35.82 peak 2 2187.500 37.45 -17.42 20.03 50.00 -29.97 AVG 3 2962.500 53.48 -14.57 38.91 70.00 -31.09 peak 4 2962.500 37.18 -14.57 22.61 50.00 -27.39 AVG 5 3537.500 51.21 -13.01 38.20 74.00 -35.80 peak 6 3537.500 35.35 -13.01 22.34 54.00 -31.66 AVG 7 4475.000 50.41 -11.79 38.62 74.00 -35.38 peak 8 4475.000 35.41 -11.79 23.62 54.00 -30.38 AVG 9 4800.000 51.33 -10.80 40.53 74.00 -33.47 peak

10 4800.000 34.95 -10.80 24.15 54.00 -29.85 AVG 11 5437.500 49.31 -8.40 40.91 74.00 -33.09 peak 12 5437.500 31.77 -8.40 23.37 54.00 -30.63 AVG

Page 15: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 14 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

4 Conducted Emission

4.1 Conducted Emission Measurement

4.2 Power Line Conducted Emission (Frequency Range 150KHz-30MHz)

FREQUENCY (MHz) Class A (dBuV) Class B (dBuV)

Quasi-peak Average Quasi-peak Average

0.15 -0.5 79.00 66.00 66 - 56 * 56 - 46 *

0.50 -5.0 73.00 60.00 56.00 46.00

5.0 -30.0 73.00 60.00 60.00 50.00

Note:

(1) The tighter limit applies at the band edges.

(2) The limit of " * " marked band means the limitation decreases linearly with the logarithm of the frequency in the range.

4.3 Measurement instruments List

Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated

until 1 Pulse Limiter MTS-systemtechnik MTS-IMP-136 261115-010-0024 12/17/2018

2 EMI Test Receiver R&S ESCI 101308 12/17/2018

3 LISN AFJ LS16 16011103219 12/17/2018

4 LISN SCHWARZBECK NSLK 8127 8127-432 12/17/2018

5 Software Farad EZ-EMC Ver. ATT-03A N/A

Rema: ” N/A” denotes No Model No. , Serial No. or No Calibration specified.

Page 16: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 15 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

4.4 Test Procedure

The EUT was placed 0.8 meters from the horizontal reference ground plane and 0.4meters from vertical reference ground plane with EUT being connected to the power mains through a line impedance stabilization network (LISN). All other support equipments powered from additional LISN(s). The LISN provide 50 Ohm/ 50uH of coupling impedance for the measuring instrument. Interconnecting cables that hang closer than 40 cm to the ground plane shall be folded back and forthin the center forming a bundle 30 to 40 cm long.

I/O cables that are not connected to a peripheral shall be bundled in the center. The end of the cable may be terminated, if required, using the correct terminating impedance. The overall length shall not exceed 1 m. LISN at least 80 cm from nearest part of EUT chassis.

For the actual test configuration, please refer to the related Item –EUT Test Photos.

4.5 Deviation From Test Standard

No deviation

4.6 Test Setup

4.7 EUT Operating Conditions

The EUT exercise program used during radiated and/or conducted emission measurement was designed to exercise the various system components in a manner similar to a typical use.

Page 17: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 16 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

4.8 Test Results

EUT: CALM. Module Model No.: SVN-840C Temperature: 23   Relative Humidity: 52%

Test Power: DC 5V Probe: L1 Test Result: Pass Test Time: 2018-11-12 Test By: Smile Standard: (CE)EN301 489 Test Mode: BT Note:

No. Frequency Reading Correct Result Limit Margin Remark

(MHz) (dBuV) Factor(dB) (dBuV) (dBuV) (dB) 1 0.2100 25.46 11.06 36.52 63.20 -26.68 QP 2 0.2100 10.10 11.06 21.16 53.20 -32.04 AVG 3 0.4580 23.89 10.23 34.12 56.73 -22.61 QP 4 0.4580 16.79 10.23 27.02 46.73 -19.71 AVG 5 1.0980 20.18 10.10 30.28 56.00 -25.72 QP 6 1.0980 13.75 10.10 23.85 46.00 -22.15 AVG 7 1.4420 17.05 10.10 27.15 56.00 -28.85 QP 8 1.4420 12.25 10.10 22.35 46.00 -23.65 AVG 9 3.6500 18.19 10.15 28.34 56.00 -27.66 QP

10 3.6500 10.65 10.15 20.80 46.00 -25.20 AVG 11 15.1300 26.40 10.17 36.57 60.00 -23.43 QP 12 15.1300 19.23 10.17 29.40 50.00 -20.60 AVG

Page 18: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 17 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

EUT: CALM. Module Model No.: SVN-840C Temperature: 23   Relative Humidity: 52% Test Power: DC 5V Probe: N Test Result: Pass Test Time: 2018-11-12 Test By: Smile Standard: (CE)EN301 489 Test Mode: BT Note:

No. Frequency Reading Correct Result Limit Margin Remark

(MHz) (dBuV) Factor(dB) (dBuV) (dBuV) (dB) 1 0.1539 32.91 11.44 44.35 65.78 -21.43 QP 2 0.1539 14.70 11.44 26.14 55.78 -29.64 AVG 3 0.4740 23.84 10.21 34.05 56.44 -22.39 QP 4 0.4740 17.45 10.21 27.66 46.44 -18.78 AVG 5 1.3180 20.98 10.10 31.08 56.00 -24.92 QP 6 1.3180 18.19 10.10 28.29 46.00 -17.71 AVG 7 1.6980 19.97 10.11 30.08 56.00 -25.92 QP 8 1.6980 14.62 10.11 24.73 46.00 -21.27 AVG 9 3.6300 19.31 10.15 29.46 56.00 -26.54 QP

10 3.6300 12.03 10.15 22.18 46.00 -23.82 AVG 11 15.5299 31.22 10.16 41.38 60.00 -18.62 QP 12 15.5299 22.61 10.16 32.77 50.00 -17.23 AVG

Page 19: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 18 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

5 Voltage Fluctuation And Flicks Measurement

5.1 Limits of Voltage Flucturtion And Flicks Measurement

Tests Limits

Descriptions IEC61000-4-15 IEC 61000-3-3

Pst 1.0, Tp= 10 min. 1.0, Tp= 10 min. Short Term Flicker Indicator Plt 0.65, Tp=2 hr. 0.65, Tp=2 hr. Long Term Flicker Indicator dc 3.3 % 3.3 % Relative Steady-State V-Chang

dmax 4 % 4 % Maximum Relative V-change d (t) 3.3% 3.3% Relative V-change characteristic

Tmax for d (t)

500 ms 500 ms Maximum time duration

5.2 Measurement Instruments List

Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated until

1 Low Frequency

Measurement System EMC-Partner HARMONIC1000 130488 05/11/2019

5.3 Test Procedure

Harmonic Current Test: Test was performed according to the procedures specified in Clause 5.0 of IEC555-2 and/or Sub-clause 6.2 of IEC/EN 61000-3-2 depend on which standard adopted for compliance measurement. Fluctuation and Flickers Test: Tests was performed according to the Test Conditions/Assessment of Voltage Fluctuations specified in Clause 5.0/6.0 of IEC555-3 and/or Clause 6.0/4.0 of IEC 61000-3-3 depend on which standard adopted for compliance measurement. All types of harmonic current and/or voltage fluctuation in this report are assessed by direct measurement using flicker-meter. For the actual test configuration, please refer to the related Item –EUT Test Photos.

5.4 Deviation From Test Standard

No deviation

Page 20: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 19 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

5.5 Test Setup

5.6 EUT Operting Conditions

The EUT tested system was configured as the statements of 2.2 Unless otherwise a special operating condition is specified in the follows during the testing.

Page 21: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 20 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

5.7 Test Results

EUT: CALM. Module Model No. : SVN-840C

Temperature: 24 ℃ Relative Humidity: 55 % Pressure: 1004 hPa Test Power : DC 5V Test Mode : BT

Page 22: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 21 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

6 Electrostatic discharge (ESD) 6.1Test equipment Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated until

1 Electrostatic Discharge

Simulator KIKUSUI KES4021 KC003242 03/026/2019

6.2 Block diagram of test setup

6.3 Test levels and performance criterion

Test Level Performance Criteria

Air Discharge 2kV, 4kV and 8kV B

Contact Discharge 2kV and 4kV

Performance criteria B description: During the test, degradation of performance is allowed. However, no

change of operating state or stored data is allowed to persist after the test. After the test, the EUT shall

continue to operate as intended without operator intervention. No degradation of performance or loss of

function is allowed, after the application of the phenomena below a performance level specified by the

manufacturer, when the EUT is used as intended.

Page 23: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 22 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

6.4 Test Procedure

Air Discharge:

The test was applied on non-conductive surfaces of EUT. The round discharge tip of the discharge

electrode

was approached as fast as possible to touch the EUT. After each discharge, the discharge electrode was

removed from the EUT. The generator was re-triggered for a new single discharge and repeated 20 times

for each pre-selected test point. This procedure was repeated until all the air discharge completed.

Contact Discharge:

All the procedure was same as air discharge. Except that the generator was re-triggered for a new

single discharge and repeated 50 times for each pre-selected test point. The tip of the discharge

electrode was touching the EUT before the discharge switch was operated.

Indirect discharge for horizontal coupling plane:

At least 20 single discharges were applied to the horizontal coupling plane, at points on each side of

the EUT. The discharge electrode positions vertically at a distance of 0.1m from the EUT and with the

discharge electrode touching the coupling plane.

Indirect discharge for vertical coupling plane:

At least 20 single discharges were applied to the center of one vertical edge of the coupling plane. The

coupling plane, of dimensions 0.5m X 0.5m, was placed parallel to, and positioned at a distance of

0.1m from the EUT. Discharges were applied to the coupling plane, with this plane in sufficient different

positions that the four faces of the EUT are completely illuminated.

Page 24: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 23 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

6.5 Test result

PASS. (See below detailed test result)

ESD Test Record

EUT : CALM. Module M/N : SVN-840C

Power Supply : 5Vd.c

Ambient Condition : 23 ℃ 50 %RH 100.1 kPa

Test Times : 10 times at each point for contact discharge;

20 times at each point for air discharge.

Memo :

Operation Mode

Type of discharge Test point Test Level Performance Result

Required

Observation

(Pass/Fail)

BT

Contact to EUT / 2kV and 4kV

B N/A N/A

Contact to Coupling Planes

/ 2kV and 4kV

B A PASS

Air / 2kV, 4kV and 8kV

B N/A N/A

Test Point:

No Description No Description No Description 1 Metal 2 Gap

Observation Description: Operation as intend, no loss of function during test and after test.

Page 25: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 24 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

7 Continuous radio frequency disturbances

7.1 Test equipment Item Kind of Equipment Manufacturer Type No. Serial No. Calibrated until

1 Signal Generator Aglilet N517113-50B MY53050160 12/11/2018

2 Amplifier A&R 150W1000M3 313157 12/11/2018

3 Log-periodic Antenna Schwarzbeck STLP 9128E 9.13E-09 12/11/2018

4 Isotropic Field Probe A&R FL7006 342652 12/11/2018

5 Amplifier A&R 50SIG6M2 342835 12/11/2018

6 Horn Antenna Schwarzbeck STLP9149 9149.222 12/11/2018

7.2 Block diagram of test setup

Page 26: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 25 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

7.3 Test levels and performance criterion

Performance criteria A description: During and after the test the EUT shall continue to operate as intended

without operator intervention. No degradation of performance or loss of function is allowed below a minimum

performance level specified by the manufacturer when the EUT is used as intended.

7.4 Test Procedure

The test procedure was in accordance with EN 61000-4-3

The testing was performed in a fully anechoic chamber. The transmit antenna was located at a distance of 3

meters from the EUT.

The frequency range is swept from 80 MHz to 6000 MHz, with the signal 80%

amplitude modulated with a 1 kHz sine-wave. The rate of sweep did not exceed 1.5 x 10 -3 decade/s, where

the frequency range is swept incrementally; the step size was 1% of preceding frequency value.

The dwell time at each frequency shall be not less than the time necessary for the EUT to be able to

respond.

The test was performed with the EUT exposed to both vertically and horizontally polarized fields on each of

the four sides.

The frequency on which the transmitter part of the EUT is intended to operate shall be excluded from

conducted and radiated emission measurements when performed in transmit mode of operation.

Note: This test was subcontracted to Bureau of Quality and Technology Supervision of Dongguan City.

Test Level Performance CriteriaFrequency 80MHz-6000MHz

A

Field Strength 3V/m measured unmodulated

Modulation AM modulated to a depth of 80% by

a sinusoidal audio signal of 1KHz

Step Size 1% increments

Dwell time 3 Sec.

Page 27: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 26 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

7.5 Test result PASS. (See below detailed test result)

R/S Test Record EUT : CALM. Module M/N : SVN-840C

Power Supply : 5Vd.c

Ambient Condition : 24 ℃ 52 %RH 100.2 kPa

Field Strength : ■3V/m □10V/m □Other: Steps:□1% □other: Dwell time: ■3s □other:

Frequency Range : ■80MHz---6GHz;□other:

Modulation : □None ■AM ■1KHz □400Hz Modulation depth: ■80% □other:

Memo:

Operation

Mode

EUT Position

towards

antenna

Antenna: Horizontal Antenna: Vertical Result

RequiredObservatio

n Required

Observati

on (Pass/Fail)

BT mode

Front A A A A PASS

Right A A A A PASS

Rear A A A A PASS

Left A A A A PASS

Observation Description: Operation as intend, no loss of function during test and after test

Page 28: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 27 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

8 TEST AND EUT PHOTO

Conducted Measurement Photos

Radiated Measurement Photos

Page 29: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 28 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

Page 30: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 29 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

EUT Photo

Page 31: ETSI EN301 489 EMC TEST REPORT - CALM....Dec 18, 2018  · EN 301489-1 V3.2.0 §9.2 PASS Electrostatic discharge EN 301489-1 V3.2.0 §9.3 PASS Fast transients EN 301489-1 V3.2.0 §9.4

Report No.: 18EEAS10002 31 30 of 30

DongGuan ShuoXin Electronic Technology Co., Ltd. Zone A, 1F, No. 6, XinGang Road YuanGang Street, XinAn District, ChangAn Town, DongGuan City, GuangDong, China Phone: 86-769-3902 6866; Fax: 86-769-8509 8777 E-mail: [email protected] Rev. 2.0

END OF REPORT