18
EU Craft Project: Cod Light Tech EU Craft Project: Cod Light Tech Light Scanning Results Light Scanning Results Collafirth and Vidlin Sites Collafirth and Vidlin Sites 12-9-06 12-9-06 Scanning Provided by IoA, University of Stirling Scanning Provided by IoA, University of Stirling

EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Embed Size (px)

Citation preview

Page 1: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

EU Craft Project: Cod Light TechEU Craft Project: Cod Light TechLight Scanning ResultsLight Scanning Results

Collafirth and Vidlin SitesCollafirth and Vidlin Sites12-9-0612-9-06

Scanning Provided by IoA, University of StirlingScanning Provided by IoA, University of Stirling

Page 2: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Ambient Light Daytime Scan (W m-2)Daytime ambient intensity changes with depth

Depth (m)

-2 0 2 4 6 8 10 12 14 16

Inte

nsi

ty (

Wat

ts m

-2)

0.1

1

10

100

Page 3: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

CCL Horizontal Intensity Scan (W m-2)

NOTE: scan performed on clean CCL unit.

NOTE: Comparisons are made with Metal Halide lights from data for other sites.

Page 4: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

CCL Performance: Site comparisons

Page 5: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Site DescriptionsCollafirth20 x 100w CCL

1.5m under surface, 0.5m between units~15m deep 30m diam circles

Conical net~60,000 0.9kg cod/cage

Vidlin6 x 400w Metal Halide

Four @ 4m Two @ 8m depth

~15m deep 30m diam circles

Cut-down Volume net

~10,000 2.5kg cod/cage

Page 6: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Position of Light measurements

• Measurements at 2m intervals along each transect line (broken line)

• Transect lines denote direction of scans for interpretation from figures

• Depth readings taken at 1m intervals from surface to cage floor

• All results watts/m2

5m

5m

Page 7: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Effect of Bio-fouling?

NOTE: Before making intensity comparison between sites, CCL units had between 5-7weeks bio-fouling accumulation, undoubtedly will have had significant

effects on profiles obtained for working cages.

Page 8: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Vidlin 6x400W MHSURFACE

0.004

0.004

0.004

0.004

0.004

0.0040.004

0.002

0.002

0.002

0.002

0.002

0.0020.002

0.002

0.002

0.002

0.004

0.004

0.004

0.004

0.0040.004

0.006

0.006

0.006

0.006

0.012

0.0100.0100.0080.008

0.0060.006

0.0060.006

0.002

0.002

0.004

0.004

0.004

0.004

0.0040.004

0.004

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

Collafirth 20 x 100W CCLSURFACE

0.0350.0300.025

0.0200.020 0.0150.0150.0100.010

0.005

0.005

0.005

0.0350.0300.025

0.0200.020 0.0150.0150.0100.010

0.005

0.005

0.005

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

Surface

Note: red line denotes approximate cage circumference for the given depth

Note: average intensity and variation at each depth given in bold type below

0.0021 ± 0.0080 W/m2 0.0043 ± 0.0021 W/m2

Page 9: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Vidlin 6x400W MH1m

0.003

0.003

0.003

0.002

0.002

0.002

0.002

0.002

0.001

0.001

0.001

0.001

0.001

0.001

0.001

0.0010.001

0.001

0.001

0.001

0.003

0.003

0.004

0.004

0.004

0.004

0.0020.002

0.003

0.003

0.003

0.002

0.0060.006

0.005

0.005

0.005

0.007

0.0020.002

0.003

0.002

0.002

0.003

0.004

0.002

0.002

0.003

0.002

0.002

0.002

0.003

0.003

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

1m DepthCollafirth 20 x 100W CCL

1m

0.001

0.001

0.001

0.001

0.001

0.002

0.003

0.0100.0090.0080.0070.0060.0050.004

0.0040.003

0.002

0.002

0.001

0.001

0.001

0.001

0.001

0.002

0.003

0.0100.0090.0080.0070.0060.0050.004

0.0040.003

0.002

0.002

0.001

0.001

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

Note: red line denotes approximate cage circumference for the given depth

0.0018 ± 0.0025 W/m2 0.0033 ± 0.0012 W/m2

Page 10: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Vidlin 6x400W MH2m

0.002

0.002

0.002

0.0020.002

0.001

0.001 0.001

0.001

0.001

0.001

0.001

0.001

0.001

0.001

0.001

0.0030.003

0.003

0.003

0.003

0.0030.003

0.004

0.0040.004

0.0020.002

0.0020.002

0.002

0.0020.002

0.0020.002

0.0020.002

0.002

0.0020.003

0.003

0.002

0.002

0.003

0.003

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

2m DepthCollafirth 20 x 100W CCL

2m

0.002

0.002

0.0020.002

0.002

0.002

0.001 0.001

0.001

0.001

0.001

0.0010.001

0.001

0.0070.0070.0060.006

0.005

0.005

0.0050.004

0.0040.004

0.0040.003

0.003

0.003

0.0030.003

0.003

0.0120.0110.010

0.0090.0090.0080.008

0.002

0.002

0.0020.002

0.003

0.0030.003

0.002

0.0040.0040.002

0.004

0.002

0.003

0.0070.007 0.0060.006

0.005

0.005

0.005

0.0120.0110.010

0.0090.009 0.0080.008

0.001

0.001

0.001

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

Note: red line denotes approximate cage circumference for the given depth

0.0033 ± 0.0036 W/m2 0.0029 ± 0.0008 W/m2

Page 11: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Vidlin 6x400W MH3m

0.002 0.002

0.002

0.002

0.0020.002

0.002

0.002

0.002

0.004

0.004

0.0160.0140.012

0.0100.0100.0080.008

0.006

0.006

0.006

0.004

0.004

0.006

0.004

0.004

0.004

0.004

0.0160.0140.012

0.0100.010 0.0080.008

0.006

0.006

0.006

0.004

0.0040.006

0.004

0.004

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

3m DepthCollafirth 20 x 100W CCL

3m

0.001

0.001

0.001

0.001

0.001

0.001

0.001

0.001

0.001

0.0070.0050.005

0.0030.003

0.005

0.0050.005

0.003 0.003

0.0030.003

0.003

0.0030.003

0.003

0.009 0.0070.007

0.007

0.005

0.005

0.005

0.005

0.003

0.0070.0050.005

0.001

0.003

0.003

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

Note: red line denotes approximate cage circumference for the given depth

0.0037 ± 0.0026 W/m2 0.0048 ± 0.0039 W/m2

Page 12: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Vidlin 6x400W MH4m

0.02 0.02

0.02

0.02

0.010.01

0.01

0.01

0.010.01

0.01

0.01

0.01

0.04

0.03

0.030.03

0.03

0.020.02

0.02

0.050.050.050.04

0.040.04

0.03 0.03

0.03

0.03

0.030.05

0.040.04

0.01

0.010.01

0.01

0.02

0.03

0.02

0.04

0.02

0.02

0.04

0.02

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

4m DepthCollafirth 20 x 100W CCL

4m

0.001 0.001

0.001

0.001

0.0010.001

0.001

0.001

0.001

0.0190.0160.0130.0100.007

0.004 0.004

0.004

0.0100.007

0.007

0.007

0.004

0.0040.004

0.0070.004

0.004

0.004

0.0070.0070.010

0.007

0.004

0.0190.0160.013

0.0100.0100.007

0.007

0.010

0.007

0.004

0.004

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

Note: red line denotes approximate cage circumference for the given depth

0.0063 ± 0.0059 W/m2 0.0260 ± 0.0177 W/m2

Page 13: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Vidlin 6x400W MH5m

0.05

0.050.05

0.03 0.03

0.030.03

0.01

0.01

0.01

0.01

0.01

0.010.01

0.01

0.01

0.01

0.05

0.05

0.05

0.05

0.030.03

0.030.03

0.03 0.07

0.070.07

0.07

0.07

0.07

0.190.170.150.13

0.110.110.090.09

0.11 0.090.09

0.05

0.07

0.03

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

5m DepthCollafirth 20 x 100W CCL

5m

0.004

0.002 0.002

0.002

0.002

0.0100.008

0.006

0.006

0.006

0.006

0.006

0.006

0.004

0.004

0.002

0.002

0.002

0.004

0.0080.008

0.004

0.004

0.004

0.004

0.0060.0060.006

0.0120.010

0.0080.008

0.008

0.004

0.0100.002

0.0020.004

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

Note: red line denotes approximate cage circumference for the given depth

0.0058 ± 0.0038 W/m2 0.0589 ± 0.0469 W/m2

Page 14: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Vidlin 6x400W MH6m

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.01

0.030.03

0.03

0.070.07

0.05

0.05

0.05

0.09

0.030.03

0.030.03

0.050.05

0.03

0.03

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

6m DepthCollafirth 20 x 100W CCL

6m

0.0030.002

0.002

0.001 0.001

0.001

0.001

0.0010.001

0.001

0.001

0.003

0.003

0.0030.003

0.002

0.0020.002

0.002

0.003

0.004

0.002

0.0100.0090.0080.007

0.0060.006 0.0050.0050.004

0.004

0.004

0.002

0.003

0.003

0.0040.003

0.0030.002

0.002

0.002

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

Note: red line denotes approximate cage circumference for the given depth

0.0032 ± 0.0021 W/m2 0.0390 ± 0.0242 W/m2

Page 15: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Vidlin 6x400W MH7m

0.01

0.01

0.01

0.01

0.010.01

0.01

0.01

0.03

0.03

0.03

0.030.03

0.05

0.130.11

0.090.090.070.07

0.05

0.05

0.05

0.03

0.03

0.05

0.03

0.03

0.05

0.03

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

7m DepthCollafirth 20 x 100W CCL

7m

0.0010

0.0015

0.0015

0.00150.0015

0.0010

0.00100.0010

0.0010

0.0020

0.0025

0.0025

0.00250.0020

0.0020

0.00300.0030

0.0035

0.0015

0.00150.0020

0.0010

0.0010

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

Note: red line denotes approximate cage circumference for the given depth

0.0017 ± 0.0009 W/m2 0.0397 ± 0.0358 W/m2

Page 16: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Vidlin 6x400W MH8m

0.03

0.030.03

0.03

0.01

0.01

0.010.01

0.01

0.01

0.05

0.05

0.05

0.150.13

0.110.110.090.09

0.070.070.17

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

8m DepthCollafirth 20 x 100W CCL

8m

0.001

0.001

0.001

0.001

0.001

0.0010.002

0.002

0.002

0.002

0.005

0.0040.0040.0030.003

0.0010.002

0.001

0.001

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

Note: red line denotes approximate cage circumference for the given depth

0.0018 ± 0.0014 W/m2 0.0663 ± 0.0651 W/m2

Page 17: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Vidlin 6x400W MH9m

0.025

0.0250.025

0.0250.015

0.0150.015

0.015

0.005

0.005

0.0050.005

0.005

0.005

0.0350.0350.0650.055

0.0450.045

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

9m DepthCollafirth 20 x 100W CCL

9m

0.0005

0.0005

0.0005

0.0005

0.0005

0.0005

0.0015

0.0015

0.0015

0.0035

0.00250.0025

0.0005

0.0005

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

Note: red line denotes approximate cage circumference for the given depth

0.0011 ± 0.0011 W/m2 0.0362 ± 0.0257 W/m2

Page 18: EU Craft Project: Cod Light Tech Light Scanning Results Collafirth and Vidlin Sites 12-9-06 Scanning Provided by IoA, University of Stirling

Vidlin 6x400W MH10m

0.005

0.0050.005

0.005

0.0250.015

0.015

0.015

0.035

0.0250.025

0.025

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

10m DepthCollafirth 20 x 100W CCL

10m

0.0010

0.0010

0.0010

0.0010

0.00250.0020

0.00150.0015

0.0010

X Dist (m)

0 5 10 15 20 25 30

Y D

ist (

m)

0

5

10

15

20

25

30

Note: red line denotes approximate cage circumference for the given depth

0.0010 ± 0.0009 W/m2 0.0284 ± 0.0123 W/m2