Upload
caraiane-catalin
View
12
Download
1
Embed Size (px)
DESCRIPTION
Container
Citation preview
FLAT PACK
roof
pillars
floor
full
window
sanitar window
doordoor with window
for air conditiondouble window
wall elements
INDEPENDED INDIVIDUAL MODUL
EUROmodul CONTAINER SYSTEM FOR MODULAR CONSTRUCTIONS
Group system of modular
construction container facility
on location
ELEMENTS OF THE SYSTEM
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472340
| con tai n er sy stems
Container TYPE:
ISO standard dimensions 20 optionally 10 up to 30
lenght = 6.058 mm (optionally 3.048 - 9.100 mm)
width = 2.438 mm (optionally 3.000 mm)
exterior height = 2.591 mm (optionally 2.791 mm or 3100 mm)
inner height = 2.300 mm (optionally 2.500 mm or 2800 mm)
Construction
ZINCED metal profyles 3 mm welded ZINCED metal profyles 3 mm connected with screws
Container construction
colour RAL 3002 (red) non painted
option: on customer wish in RAL colour option: painted on customer wish in RAL colour
Floor
option:
Floor openings for forklift
With forklift pockets Without forklift pockets(for containers up to 7.335 mm, holes distance1.506 mm) option: With forklift pockets (for containers up to 7.335 mm, holes distance1.506 mm)
Roof
option:
1.5 mm VINYL DRESSING 19 mm OSB board PU PANEL 50 mm RIB
LAMINATE OR CHERAMIC TILES PU PANEL 50 mm RIB
0.63 mm ZINCED STEEL PLATE 100 mm MINERAL WOOL STEEL 40 x 80 mm PVC foil vapour barrier Enriched white chipboard10 mm
50 + 40 mm PU PANEL
ZINCED STEEL PLATE COVER 0,6 mm 100 mm MINERAL WOOL STEEL 40 x 80 mm PVC foil vapour barrier Enriched white chipboard 10 mm
1. Elements of the system EUROmodul modular building structuresElements of modular building structures are an expression of the serial factory production systems of mainly STANDARD components - elements that are combined - by composing solutions or a combination of compiling the individual container modules as a higher degree of modular construction units, or complete products for the market.
1.1 Technical characteristics of elements
EUROSTANDARD STANDARD
[email protected] | www.euromodul.org | 341
c ontaine r sy ste m s |
Exteriour wall and side panels
60 mm poliurethane panel, 50 mm poliurethane panel, externally microcorrugated RAL 9002 externally microcorrugated RAL 9002internally smooth RAL 9010 (white) internally smooth RAL 9010 (white)
option: 60 mm mineral wool, bothside plasticated in RAL 9002
option : 60 mm mineral wool, exteriour side plasticated in RAL 9002, internally enriched chipboard 100 WHITE010 (white)
Exteriour and inner walls
PVC with polyurethane filling 40 mm, clear opening 79/202 cm
Windows and doors
PVC, windows with shutters PVC without shutters
optionally: windows without shutters optionally: windows with shutters
Isolation, coefficient of thermal resistance
Floor = U = 0,32 W / m2K Floor = U = 0,37 W / m2K
Roof = U = 0,37 W / m2K Roof = U = 0,39 W / m2K
Wall panels = U = 0,41 W / m2K Wall panels = U = 0,41 W / m2K
Window = U = 2,40 W / m2K Window = U = 2,40 W / m2K
EUROSTANDARD STANDARD
EUROSTANDARD container type with zinced and painted construction (blue coloured pannels as option) exteriour power connections inside roof construction, one door two windows with shutters forklift openings
p
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472342
| con tai n er sy stems
1103 office / living container with lobby, two doors, two windows, thermoisolated, finished el. cables, fuses, three ceiling lights, two sockets, PVC floor, without inner equipment
p 1108 sanitary container equipped with 2 WC cabins, 5 wash basins, 2 pissoirs, boiler, 2 showers, 4 windows, thermoisolated
p
2. Individual EUROmodul container modules
2.1 Individual EUROmodul container modulesThey are assembled in SERIAL factory production from SERIAL manufactured elements. They come to the market as finished product as residential or office space equipped with or without equipment.
Individual container modules are used as a single objects as bungalows, dormitories, offices, warehouses, shops, workshops and a built MODULE for the construction of various shapes and purposes.
pSTANDARD container type
with zinced construction one door two windows
[email protected] | www.euromodul.org | 343
c ontaine r sy ste m s |
Dimensions (mm) and weights (kg)
external internal (starting) weight
type lenght width height** lenght width height assembled FLAT PACK
assembled FLAT PACK
10 2,990 2,438 2,600 650 - 700 2,760 2,200 2,300 1,315 1,377
16 4,885 2,438 2,600 650 - 700 4,650 2,200 2,300 1,725 1,785
20 6,058 2,438 2,600 650 - 700 5,830 2,200 2,300 1,970 2,030
*24 7,355 2,438 2,600 650 - 700 7,125 2,200 2,300 2,295 2,357
*30 9,120 2,438 2,600 650 - 700 8,890 2,200 2,300 2,765 2,825
* as option **optionally also available with an external height of 2,800 mm / internal height 2,500 mm / FLAT PACK height 900 mm
interior toilet container with urinals and
washbasins
p
2.2 Tehnical features of container modules
| tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472344
| con tai n er sy stems
Location preparation
for one container: for 2, 4 and more containers
Handling and lifting
By fork: angle between roof and cable must be at last 60o
option: Forklift for lifting containers up to 7.3 m in lenght if container has forklift holes
6.060 mm
2.44
0 m
m
6.060 mm 6.060 mm
2.44
0 m
m2.
440
mm
Electric installations
Volt 230/400V, 50 Hz, 3/5 pole, 32A,
FID socket 40/0.03A, fuses 16 A i 10 A
Two sockets, two fluo tubes 2 x 58W
Grounding on location is made by customer, with zinced cable on container and adequate holders - plates
Installation inspection and grounding must be done by authorised people
Electrical heater 2 kW
CEE sockets in roof construction with cable connection On-wall sockets
option: sockets in construction
electric installations are inside panels electric installations are inside plastic covers
option: Ventilation to ensure relative humidity up to 60% on 20oC in order to avoid condensation
option: Air condition / heating or only air condition
Load
Floor = 250 kg / m2
Roof = 200 kg / m2
Side (wind) = 90 kg / m2 in case of side wind object fixcation on the ground
SOCKETSOCKET
EUROSTANDARD STANDARD
SOCKET
[email protected] | www.euromodul.org | 345
c ontaine r sy ste m s |