6
FLAT PACK roof pillars floor full window sanitar window door door with window for air condition double window wall elements INDEPENDED INDIVIDUAL MODUL EUROmodul CONTAINER SYSTEM FOR MODULAR CONSTRUCTIONS Group system of modular construction container facility on location ELEMENTS OF THE SYSTEM | tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472 340 | container systems

Euromodul Containers System Constructions En

Embed Size (px)

DESCRIPTION

Container

Citation preview

  • FLAT PACK

    roof

    pillars

    floor

    full

    window

    sanitar window

    doordoor with window

    for air conditiondouble window

    wall elements

    INDEPENDED INDIVIDUAL MODUL

    EUROmodul CONTAINER SYSTEM FOR MODULAR CONSTRUCTIONS

    Group system of modular

    construction container facility

    on location

    ELEMENTS OF THE SYSTEM

    | tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472340

    | con tai n er sy stems

  • Container TYPE:

    ISO standard dimensions 20 optionally 10 up to 30

    lenght = 6.058 mm (optionally 3.048 - 9.100 mm)

    width = 2.438 mm (optionally 3.000 mm)

    exterior height = 2.591 mm (optionally 2.791 mm or 3100 mm)

    inner height = 2.300 mm (optionally 2.500 mm or 2800 mm)

    Construction

    ZINCED metal profyles 3 mm welded ZINCED metal profyles 3 mm connected with screws

    Container construction

    colour RAL 3002 (red) non painted

    option: on customer wish in RAL colour option: painted on customer wish in RAL colour

    Floor

    option:

    Floor openings for forklift

    With forklift pockets Without forklift pockets(for containers up to 7.335 mm, holes distance1.506 mm) option: With forklift pockets (for containers up to 7.335 mm, holes distance1.506 mm)

    Roof

    option:

    1.5 mm VINYL DRESSING 19 mm OSB board PU PANEL 50 mm RIB

    LAMINATE OR CHERAMIC TILES PU PANEL 50 mm RIB

    0.63 mm ZINCED STEEL PLATE 100 mm MINERAL WOOL STEEL 40 x 80 mm PVC foil vapour barrier Enriched white chipboard10 mm

    50 + 40 mm PU PANEL

    ZINCED STEEL PLATE COVER 0,6 mm 100 mm MINERAL WOOL STEEL 40 x 80 mm PVC foil vapour barrier Enriched white chipboard 10 mm

    1. Elements of the system EUROmodul modular building structuresElements of modular building structures are an expression of the serial factory production systems of mainly STANDARD components - elements that are combined - by composing solutions or a combination of compiling the individual container modules as a higher degree of modular construction units, or complete products for the market.

    1.1 Technical characteristics of elements

    EUROSTANDARD STANDARD

    [email protected] | www.euromodul.org | 341

    c ontaine r sy ste m s |

  • Exteriour wall and side panels

    60 mm poliurethane panel, 50 mm poliurethane panel, externally microcorrugated RAL 9002 externally microcorrugated RAL 9002internally smooth RAL 9010 (white) internally smooth RAL 9010 (white)

    option: 60 mm mineral wool, bothside plasticated in RAL 9002

    option : 60 mm mineral wool, exteriour side plasticated in RAL 9002, internally enriched chipboard 100 WHITE010 (white)

    Exteriour and inner walls

    PVC with polyurethane filling 40 mm, clear opening 79/202 cm

    Windows and doors

    PVC, windows with shutters PVC without shutters

    optionally: windows without shutters optionally: windows with shutters

    Isolation, coefficient of thermal resistance

    Floor = U = 0,32 W / m2K Floor = U = 0,37 W / m2K

    Roof = U = 0,37 W / m2K Roof = U = 0,39 W / m2K

    Wall panels = U = 0,41 W / m2K Wall panels = U = 0,41 W / m2K

    Window = U = 2,40 W / m2K Window = U = 2,40 W / m2K

    EUROSTANDARD STANDARD

    EUROSTANDARD container type with zinced and painted construction (blue coloured pannels as option) exteriour power connections inside roof construction, one door two windows with shutters forklift openings

    p

    | tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472342

    | con tai n er sy stems

  • 1103 office / living container with lobby, two doors, two windows, thermoisolated, finished el. cables, fuses, three ceiling lights, two sockets, PVC floor, without inner equipment

    p 1108 sanitary container equipped with 2 WC cabins, 5 wash basins, 2 pissoirs, boiler, 2 showers, 4 windows, thermoisolated

    p

    2. Individual EUROmodul container modules

    2.1 Individual EUROmodul container modulesThey are assembled in SERIAL factory production from SERIAL manufactured elements. They come to the market as finished product as residential or office space equipped with or without equipment.

    Individual container modules are used as a single objects as bungalows, dormitories, offices, warehouses, shops, workshops and a built MODULE for the construction of various shapes and purposes.

    pSTANDARD container type

    with zinced construction one door two windows

    [email protected] | www.euromodul.org | 343

    c ontaine r sy ste m s |

  • Dimensions (mm) and weights (kg)

    external internal (starting) weight

    type lenght width height** lenght width height assembled FLAT PACK

    assembled FLAT PACK

    10 2,990 2,438 2,600 650 - 700 2,760 2,200 2,300 1,315 1,377

    16 4,885 2,438 2,600 650 - 700 4,650 2,200 2,300 1,725 1,785

    20 6,058 2,438 2,600 650 - 700 5,830 2,200 2,300 1,970 2,030

    *24 7,355 2,438 2,600 650 - 700 7,125 2,200 2,300 2,295 2,357

    *30 9,120 2,438 2,600 650 - 700 8,890 2,200 2,300 2,765 2,825

    * as option **optionally also available with an external height of 2,800 mm / internal height 2,500 mm / FLAT PACK height 900 mm

    interior toilet container with urinals and

    washbasins

    p

    2.2 Tehnical features of container modules

    | tel: +385 \ 51 \ 257 275 | fax: +385 \ 51 \ 258 472344

    | con tai n er sy stems

  • Location preparation

    for one container: for 2, 4 and more containers

    Handling and lifting

    By fork: angle between roof and cable must be at last 60o

    option: Forklift for lifting containers up to 7.3 m in lenght if container has forklift holes

    6.060 mm

    2.44

    0 m

    m

    6.060 mm 6.060 mm

    2.44

    0 m

    m2.

    440

    mm

    Electric installations

    Volt 230/400V, 50 Hz, 3/5 pole, 32A,

    FID socket 40/0.03A, fuses 16 A i 10 A

    Two sockets, two fluo tubes 2 x 58W

    Grounding on location is made by customer, with zinced cable on container and adequate holders - plates

    Installation inspection and grounding must be done by authorised people

    Electrical heater 2 kW

    CEE sockets in roof construction with cable connection On-wall sockets

    option: sockets in construction

    electric installations are inside panels electric installations are inside plastic covers

    option: Ventilation to ensure relative humidity up to 60% on 20oC in order to avoid condensation

    option: Air condition / heating or only air condition

    Load

    Floor = 250 kg / m2

    Roof = 200 kg / m2

    Side (wind) = 90 kg / m2 in case of side wind object fixcation on the ground

    SOCKETSOCKET

    EUROSTANDARD STANDARD

    SOCKET

    [email protected] | www.euromodul.org | 345

    c ontaine r sy ste m s |