VARIATION
Ergonomic,Clean and Professional
EURUS embodies our belief of bringing highly reliable Japan quality products to dentists in the world.
S1-Contour Chair-Chair Mount Over The Patient-Holder/Place/Rod-Unit Mounted LED Light
S3-Contour Chair-Pedestal Over The Patient-Holder/Place/Rod-Unit Mounted LED Light
S4-Folding Legrest Chair-Pedestal Over The Patient-Holder/Place/Rod-Unit Mounted LED Light
MADE IN JAPAN
SINCE 1921
Belmont Osaka Factory
Since 1921,Belmont provides high-quality products and service.
Highly trained workers handcraft the chair, unit and light.
ELECTRO HYDRAULIC
PATIENT WEIGHT CAPACITY
DURABILITY
200kg 165kg
CHAIR
Gear system-Noise,vibration and short life time
Belmont Hydraulic system-Smooth, quiet and long life time
NoiseVibration
Contour Chair Folding Legrest Chair
Life Time
Duration test
10 year x 240 days x 15 patient x 3 moves =108,000 moves
TWIN-AXIS HEADREST
POWER HEADREST
CHAIR
More Precise and Lighter Adjustment of Headrest- reduces burden on wrists and arm of the dentists
Control headrest position without hands
-helps female dentists to adjust it with less power
Adjustment angle EURUS: 7.5 degree Clesta2: 10.0 degree
PULLEURUS: 4.45 kgClesta2: 9.5 kg
UP & DOWN120mm stroke
Raise & ReclineFit to human head movement
PUSHEURUS: 0 kgClesta2: 3.0 kg
CONTOUR CHAIRDIMENSIONS
Unit: mmTolerance in dimensions: ±10%
2010
170
50
300
210
518
600
1055-1
615
73°
5-18°
420-
800
1380395180
Headrest: Electrohydraulic
Headrest: Manual
1975
170
50
300
103
0-15
95
73°
50° 8°
5-18°
420-
800
1380385
210
518
600
170° 235°
CHAIR
FOLDING LEGREST CHAIR
Unit: mmTolerance in dimensions: ±10%
2°18°
18°
110
0-13
65
450-
715
510 600615100 110
602
210
499
485
80°
720
1725
190
Dimensional drawing (standard values are provided)Headrest: Electrohydraulic
Headrest: Manual
2°18°
18°
109
0-13
60
450-
715
510 600580100 110
602
210
499
485 8
0°
30°
180
720
1690
190
170°
235°
180
CHAIR
Dimensions
HOLDER & PLACE TYPE UNIT
Holder Type
- Separated holder can be adjusted for suitable position
- Holder,handle,touch panel and large table are within the reach
Place Type
-3 Roller guides for each handpiece
- Roller guide holds the weight of the hose- No need to look back when returning the handpiecies
ROD TYPE UNIT
Belmont Rod Type
-Long reach of 900 mm-Flexible holder
From side of the patient
From top of the patient
Micromotor Air turbine Scaler
Tension Adjustment-Tension can be adjusted to change each handpiece’s weight to reduce the burden.
Different tension setting for handpiece
PatientPatient UserUser
HighHeaterOFF
Switch
AAdultAdult
02:30
Manual
TOUCH PANEL UNIT
Timer indicationIndicates the status of the timer function in operation
Home screen
32 different user setting
Timer switchActivates the timer function
Patient memory switchSwitches the chair setting to match the patient
Cupfiller switchFills the cup with water
Bowl flush switchCleans the bowl
User memory switchSelects user-based operation memory
Water bottle indicatorIndicates a low water bottle level alarm
Bell switchPages an assistant, etc.
Function switchSets various operating conditions
Wireless foot controller indicatorIndicates remaining battery and pairing status
HP heater switchTurns on/off the HP heater
Dental light switchTurns on/off the dental light
Light switchSwitches light operation
Lock switchLocks the function of the touch panel and the stick switch
Water heater switchTurns on/off the water heater
Child
User A
4 positions 4 positions
4 positions
4 positions
4 positions
4 positions
4 positions
4 positions
User B
User C
User D
User E
User F
Adult Elderly
MICROMOTOR UNIT
Micro motor screen
Micromotor option specs
min-1
M4M2M1 M3
WA
User A
11 1:
5,000 5,000MaxMaxVa
AUTORev
Ncm 3.0
Memory tabCalls the rotation control memory
Slide mode switchSwitches slide mode of the foot controller
+/- switchIncreases/decreases rotation or power
Gear ratio switchSwitches the indication of gear ratio
Chair lock indicatorIssues chair lock status alarm
Torque control switchMicromotor setting of torque value/automatic reverse function
Menu call switchCalls various operation menu screens
Micromotor forward/reverse switchSwitches the rotation direction
Spray air switchTurns on/off spray air flow
Spray water switchTurns on/off spray water flow
Handpiece light switchTurns on/off the handpiece light
Torque
control
Auto reverse
Aurto forward
Setting range of maximum rotation (gear ratio 1:1)
100 1000 2000 5000 6000 10000 20000 30000 40000
Rotation range
Interval of settable maximum rotation
Every 1,000
Rotation range
Interval of settable maximum rotationEvery 1,000
Rotation range
Interval of settable maximum rotationEvery 1,000
High-speed rotation range
Interval of settable maximum rotation
Every 1,000
Low-speed rotation range
Interval of settable
maximum rotation
Every
100Every 500
High-speed rotation range
Interval of settable maximum rotation
Every 1,000
(Unit: min-1)
Interval of settable
maximum rotation
Every
100Every 500
Low-speed rotation range
NSK NBX
NSK NLX nano
NSK NLX plus
Bien air MCX
Bien air MX2
Brushless
Brushless
Brushless
Brushless
Brush
Type Max Torque
2.5Ncm
3.2Ncm
4.0Ncm
2.5Ncm
3.5Ncm
Model Picture
ScalingEndoPerio
WW
User A
5 8 /1 5 10
MaxMaxVa
SCALER UNIT
Scaler screen
Scaler option specs
Slide mode switchSwitches slide mode of the foot controller
Menu call switchCalls various operation menu screens
Spray water switchTurns on/off spray water flow
Handpiece light switchTurns on/off the handpiece light
Model Picture Scaling,Perio,Endo mode
EMS No pain
Satelec Xinetic
Satelec SP4055
Newtron
NSK Varios 170
Dentsply
Cavitron
Mode tab
Output
Maximum output(displayed only in Va mode)Touch bar graph
CUSPIDOR OPTION
VACUUM CLEAN SYSTEM
UNIT
Separator and Water disinfection system
Separator model Picture Air/Water Separation
Amalgam Separation
Amalgam Separation rate
Available combination withwater disinfection system
Dürr CS1
Dürr CAS1 WEK eco light
WEK
eco lightWEK
Metasys MST1Eco Light
Metasys MST1
Dürr Spittoon
Valve
95%
95%
Avairable Variation:S3 and S4
Available configuration matrix
Available configuration
Cleaner Bottle
Wat
er d
isin
fect
inon
syst
em ty
pe W/O water disinfection system
Metasys WEK LIGHT
Metasys WEK
W/O
Sep
arat
orSingle Vacuum
Dür
rC
AS
1(In
stal
led
)
Dür
r
CA
S1(
Pre
par
atio
n)
Sp
ittoo
n va
lve
Separator typeM
etas
ys M
ST1
eco
Met
asys
MS
T1
CS
1(In
stal
led
)
Dür
r
Dür
r
Dür
rS
pitt
oon
valv
e
CS
1(In
stal
led
)D
ürr
CS
1(P
rep
arat
ion)
Separator type
W/O
Sep
arat
or
Wat
er d
isin
fect
inon
syst
em ty
pe W/O water disinfection system
Metasys WEK LIGHT
Metasys WEK
Dür
rC
S1(
Pre
par
atio
n)
Dür
rC
AS
1(In
stal
led
)
Dür
rC
AS
1(P
rep
arat
ion)
Met
asys
MS
T1 e
co
Met
asys
MS
T1Twin Vacuum
Unit and chair surfaces : VirusesContacting blood and saliva directly or aerosol from patient,viruses acquire on the chair and unit surfaces .
STAY CLEAN AND SAFE
Dental unit water line : BacteriaBacteria forms on the walls of water line inside the dental treatment center only a few days.Legionella infection is one of the common health risks of dental unit.
Dental unit vacuum line : VirusesSuctioned blood, saliva and deposits stays on encrustationof vacuum line and create microbes.Risks of Viruses including HBV,HCV and HIV without treatment.
Inside Vacuum line
Blood
Saliva
Inside water line
LimescaleBiofilm
Belmont dental treatment center provides solutions against infection to stay clean and safe during procedure.
UP & DOWN
Normal mode
Light ON/OFF
Spray ON/OFF Micromotor Forward/Reverse
Composite safe mode
Raise & Recline
TOUCHLESS CONTROL
Light touchless sensorOn/Off without touch
Foot controlBlue switch can be customizedfor doctor’s choise and controlledby foot
Power headrestAdjust headrest without hands
Reduce infection risks by cotrolling device without hands.
STAY CLEAN AND SAFETOUCHLESS CONTROL
AUTOCLAVE 134
Holder cover
Holder sleeve
Detachable handle Autoclave process.
Autoclave detachable parts after the procedure.
Before sterilization, remove dirt on the surface and wash it under running water.Be sure to put it in a sterilization bag during the sterilization process. Do not perform dry processing exceeding the sterilization temperature.Autoclaved at a temperature of 134ºC for 3 minutes.
STAY CLEAN AND SAFE
CLEANING
Vacuum clean system
Water lineFlushing system
Water lineMetasys WEK or WEK light
Barrier film up to 0.15 mm is available
Light lenz cover can be cleaned as well
Metasys Green & Clean WK(WEK system)Water decontamination system approved by DVGWWhen : Constantly
Dürr Orotol plusVacuum line disinfectionWhen : Daily
Keep the surface and inside the unit clean with disinfection material showing below.Surface
Dürr FD366Surface disinfectionWhen:After each patient
Dürr FD360Leather cleaningWhen:After each patient
FlushingWater line cleaningWhen : Daily
STAY CLEAN AND SAFE
LIGHT LIGHT
Technical Data
Dimensions
Optical performance ……… Standard irradiation distance: 650 mm In treatment mode Central illuminance: 3,000–28,000 lx Correlated color temperature: 5,000 K In Composite Safe mode (Compliant with ISO 9680: 2014 5.2.10) Central illuminance: 9,000 lx Correlated color temperature: 2,700 KIlluminance pattern ……… Pattern dimensions (length x width): 85 x 155 mm
75%50%
10%
144°
50°
989
160°
160°
5378
334
4
90°
90°
294
Unit:mm (tolerance in dimensions: ±10%)* The dimensions and specifications are subject to change without notice.