  • PROYECTO FIN DE CARRERA

    EVALUATION OF NUMERICAL METHODS FOR TURBOMACHINES BASED ON EXPERIMENTAL DATA

    FROM A FRANCIS PUMP-TURBINE IN PUMP MODE.

    AUTOR: ANA FABA TORTOSA

    MADRID, junio de 2008

    UNIVERSIDAD PONTIFICIA COMILLAS

    ESCUELA TCNICA SUPERIOR DE INGENIERA (ICAI)

    INGENIERO SUPERIOR INDUSTRIAL

  • Resumen ii

    RESUMEN

    El objetivo de este proyecto es la validacin, a partir de su comparacin con

    datos reales experimentales, de la capacidad de los mtodos CFD para

    modelar el comportamiento del flujo dinmico para fenmenos transitorios

    en turbomquinas hidrulicas.

    El caso estudiado concierne a una bomba-turbina Francis en sentido bomba.

    Un modelo a escala reducida de dicha mquina con una velocidad especfica

    = 0.19 es el utilizado en las medidas de laboratorio.

    La turbomquina est compuesta de 9 labes en la rueda y 20 canales en el

    difusor. Dos puntos de operacin distintos, uno de carga parcial y otro de

    elevada tasa de descarga, son descritos y analizados por mtodos de

    simulacin, en trminos de fluctuacions de presin a lo largo de los canales

    del estator. Estas fluctuaciones generadas por la interaccin entre el rotor y el

    estator (RSI) y los fenmenos que afectan al comportamiento del flujo a causa

    de ello forman parte del estudio realizado en este proyecto.

    La simulacin numrica de los flujos transitorios est representada gracias al

    paquete de software de ingeniera ANSYS CFX.11. para cuatro dominios de

    computacin diferentes: 3 posibles dominios parciales y tambin la mquina

    completa.

    Aunque inicialmente se realizan anlisis generales para los cuatro casos, tras

    la evaluacin de la calidad de los resultados, se detalla la investigacin para

    el ltimo caso exclusivamente. Solamente un dominio de computacin que

    incluya la mquina entera se considera que minimice los errores de CFD y

    que consiga as una simulacin fiable.

  • Resumen iii

    Esos resultados numricos precisos y detallados son comparados con las

    medidas obtenidas en los test del laboratorio, con la intencin de validar el

    mtodo y determinar los principales fallos de los mtodos CFD.

    Las medidas de presin en el marco estacionario, cuyos puntos suponen

    bsicamente todo el ncleo del anlisis, estn tomadas mediante diminutos

    sensores de presin piezoresistivos, situados en diferentes puntos de dos de

    los veinte canales del distribuidor: el primero y el ltimo.

    En general, se descubre muy buena concordancia entre la simulacin y los

    resultados del laboratorio para el punto de operacin con elevado caudal de

    descarga pero existen algunas diferencias para el de carga parcial.

    Las posibles causas y la descripcin del comportamiento del flujo estn

    desarrolladas a lo largo de este proyecto. Por ejemplo, torbellinos y pequeos

    remolinos pueden nacer debido a la falta de adaptacin entre la geometra de

    la mquina y los tringulos de velocidad del agua en cargas parciales.

    Este tipo de fenmenos aleatorios e instantneos crean un rgimen no

    permanente y un grado de inestabilidad en el comportamiento del flujo que

    no llega a predecirse ni a simularse completamente bien con los actuales

    mtodos de CFD.

    Este proyecto puede ofrecer una primera referencia de anlisis para ms

    detallados estudios en el futuro.

    De acuerdo con esto, las diferencias ms relevantes entre los resultados de

    CFD y los datos experimentales pueden ayudar a advertir dnde y cmo los

    mtodos numricos pueden ser mejorados y corregidos. Por otra parte, como

    los la simulacin en CFD ofrece resultados de la presin y todas las variables

    y propiedades del flujo en cualquier lugar y posicin de toda la mquina,

    para cualquier canal y cualquier punto en la bomba-turbina, de la

    observacin de los resultados que parezcan insospechados o ms

  • Resumen iv

    sorprendentes pueden ayudar a sugerir dnde colocar un nuevo sensor de

    presin para el prximo test de laboratorio.

    Para concluir, la comparacin de ambos resultados puede ayudar a mejorar

    el desarrollo de las mquinas hidrulicas, tanto encontrando los puntos

    dbiles de las mquinas actuales, sus riesgos y problemas de operacin as

    como corrigiendo los mtodos de CFD con la intencin de mejorarlos y

    aplicarlos al diseo y rediseo de dichas mquinas.

  • Summary v

    SUMMARY

    The aim of this project is to validate, by comparison with real experimental

    data, the ability of CFD methods to model dynamic flow behaviour for

    unsteady phenomena in hydraulic turbomachines.

    The study case concerns a Francis pump-turbine in pump mode. A reduced-

    scale model = 0.19 is used for the laboratory measurements. It is composed

    of 9 runner blades and 20 diffuser channels. Two different operating points,

    one of partial load and another of high discharge, are described and analysed

    by simulation methods, in terms of pressure fluctuactions along the stator

    channels. These fluctuacions generated by Rotor Stator Interaction (RSI) and

    the phenomena that affect the flow behaviour caused by them are part of the

    study of this paper.

    The numerical simulation of the unsteady flow is performed with ANSYS

    CFX.11 for four computing domains: 3 possible partial domains and also the

    entire machine.

    Although previous general analysis are done for the four cases, after the

    evaluation of the quality of their results, detailed investigations are finally

    made for the last one exclusively. Only a computing domain of the entire

    machine is considered to be the best to minimize the CFD errors and to get a

    reliable simulation.

    These computer results are compared with laboratory measurements in

    order to to validate the method and to determine main CFD simulation

    failures. The pressure measurements in the stationary frame, whose points

    are the mainly analysis issue, are performed with piezoresitive miniature

  • Summary vi

    pressure sensors located in several locations at two of the 20 distributor

    channels: the first and the last one.

    Very good agreement between simulation and laboratory results is found in

    general for the high discharge operating point but some discrepancies are

    discovered for the partial load one.

    Posible causes and the description of the flow behaviour are included in this

    paper. For example, eddies and small whirls can be born due to the lack of fit

    between the machine geometry and water velocity triangles at partial load.

    This type of phenomena creates instability and unsteadiness that it is not

    completely well simulated by CFD methods.

    This project can provide a first reference analysis for more detailed studies in

    the future.

    According to this, most relevant differences between CFD results and

    experimental data can help to advice where and how the numerical method

    should be improved and checked. On the other hand, as CFD results are

    obtained for the whole machine, all around the channels and at all locations

    in the pump-turbine, unexpected or surprising results discovered by the

    observation of CFD analysis for any point would suggest to include a sensor

    at that location during the next laboratory experimental test.

    To sum up, the comparison of both results can help to improve the hydraulic

    machines development, by finding current machines weaknesses, risks and

    operating problems as well as by checking the CFD methods errors, in order

    to improve them for machine design and redesign.

  • Table of Content vii

    TABLE OF CONTENT

    1 Introduction................................................................................... 2

    1.1 THE HYDRODYNA PROJECT ........................................................ 3

    1.2 Brief overview of hydro power sector situation. .......................... 3

    1.3 Introduction to Hydraulic Turbomachines. ................................... 7

    1.3.1 Variables definition. Classification of Turbomachines ...... 7

    1.3.2 Nomenclature............................................................................ 12

    1.3.3 Power conversion and Balance............................................... 14

    1.3.4 Euler equations ......................................................................... 18

    1.3.5 Rotor-stator Interaction in Francis Pump-Turbines. .......... 22

    1.3.6 Frequency Analysis. ................................................................. 26

    2 Numerical Simulation and CFD Methods ............................ 28

    2.1 Introduction to Computational Methods...................................... 28

    2.2 CFD (Computational Fluid Dynamics) ......................................... 30

    2.2.1 The Choice of the Physical Approach. .................................. 31

    2.2.2 The mathematical model ......................................................... 32

    2.2.3 The Discretization Method..................................................... 33

    2.2.4 The implementation of numerical algorithms and Solution.

    36

    2.3 CFD for Turbomachinery. ............................................................... 37

    2.4 CFD historic evolution.................................................................... 38

    2.5 CFD Error Estimation ................................................