5 6
Cooling Only Mini Series
V-Ph-Hz
Capacity kW
Power input kW
Motor Type
Factory charging kg
Liquid pipe mm
Gas pipe mm
3m /h
dB(A)
mm
mm
kg
kg
EDVC-V72W/DVN1
7.2
1.64
4.39
4
1.4
Ф9.53
Ф15.9
3400
54
973×862×302
1025×910×410
58
63
EDVC-V92W/DVN1
9.2
2.06
4.47
5
1.4
Ф9.53
Ф15.9
3400
54
973×862×302
1025×910×410
58
63
EDVC-V145W/DVN1
14.5
3.57
4.06
8
2.6
Ф9.53
Ф15.9
5100
55
1053×865×523
1120×890×560
85
92
EDVC-V170W/DVN1
17
3.99
4.26
9
2.6
Ф9.53
Ф15.9
5100
55
1053×865×523
1120×890×560
85
92
°C
Model name
Power supply
1Cooling
Fan motor
DC
Quantity
Quantity
Airow rate
Net dimensions (W×H×D)
Net weight
Gross weight
EER
Type
1
Compressor
Connected indoor units
Total capacity
Maximum quantity
Operating temperature range
1
EDVC-V110W/DVN1
11
2.75
4
6
1.4
Ф9.53
Ф15.9
3400
54
973×862×302
1025×910×410
58
63
1-phase, 220V, 50/60Hz
45-130% of outdoor unit capacity
DC inverter
Cooling: -5 to 48
R410A
Refrigerant
Type
Pipe connections
Notes: 1. Indoor air temperature 27℃ (80.6℉) DB, 19℃ (66.2℉) WB; outdoor air temperature 35℃ (95℉) DB; equivalent refrigerant piping length 7.5m (24.6ft.) with zero level difference. 2. Sound pressure level is measured at a position 1m (3.28ft.) in front of the unit and 1.3m (4.26ft.) above the oor in a semi-anechoic chamber.
Specications
Controllers Lineup
Series
Series Capacity range
Four-way
cassette
Compact
four-way cassette
Low static
pressure duct
1.8-7.1kW
2.2-7.1kW
2.8~14kW
1.5~4.5kW
1.8-7.1kW
Appearance
One-way cassette
Two-way cassette
Series Capacity rangeAppearance
Wireless
remote
controller
Wired controller
Centralized
controller
& monitor
Network control
software & gateways
Accessories
RM05 RM12RM02
KJR-29B KJR-90D KJR-86C KJR-12B KJR-120C
CCM30 MD-CCM09 KJR-90BMD-CCM03
Modbus Gateway CCM-18A
LonWorks Gateway LonGW64
IMM Software & M-Interface
Data Converter CCM15
KNX Gateway MD-KNX
BACnet Gateway CCM08
Hotel Key Card Interface Module
MD-NIM05 3-Phase ProtectorDigital Power
Ammeter
Infrared Sensor Controller MD-NIM09
AHU Control Box
Wall mounted
Ceiling & oor
1.5~14kW
7.1~20kW
1.5~9kW
3.6~16kW
High static
pressure duct
Medium static
pressure duct
3. For a system with more than one IDU, to ensure even distribution of refrigerant, the capacity of each indoor unit should not exceed 8kW.
TRADEMASTER RESOURCES CORPORATIONLot E., Impex Compound, Alabang Zapote Road, Pamplona, Las Piñas City
Contact No.: (02) 865-2900 / 872-2222Visit our website at www.trademaster-philippine.com
1
2
3
4
5
6
2 3
Easier and safer installation thanks to a branch box that simplies piping work and the adoption of screw connection.
Both left and right pipe are connecting from outdoor unit to branch box is reserved, which greatly simplies eld
installation.
High Eciency
The DC inverter compressor adopts innovative
design and numerous high performance key parts
Compressor (Twin Rotary) structure
Highly Efficient DC Motor:
- Creative motor core design
- High density neodymium magnet
- Concentrated type stator
- Wider operating frequency range
Better balance and Extremely Low Vibration:
- Twin eccentric cams
- 2 balance weights
Highly Stable Moving Parts:
- Optimal material matching rollers and vanes
- Optimize compressor drive technology
- Highly robust bearings
- Compact structure
High EER Values
All DC Fan Motors
The system controls the speed of the fan motor according to the system pressure and system load achieving the
minimum power
Newly designed window type ns enlarge the heat exchange area and decrease air resistance, enhance heat
exchange performance and save more energy.
Hydrophilic ns and internally threaded copper pipes optimize heat exchange efciency.
Wide Operation Range
Mini VRF Series operates stably under extreme conditions, 48°C
ranging from minus 5°C to 48°C.
-5°C
Wide Application Range
COOLING MODE
Wide Capacity Range The outdoor units’ capacity range from 7.2kW to 17kW which is ideal for small ofces, villas, apartment and shops,
making it perfect for commercial and residential application.
14.5kW, 17kW7.2kW, 9.2kW, 11kW
Everest provides 9 types of VRF indoor units maximum meeting
varied customer requirements. It is widely applied in market,
hospital, ofce building, hotel, airport, etc..
Wide Range of Indoor Units
The lo
ngest
pip
ing le
ngth
is 7
0m
The
rst bra
nch
join
t to
the
fart
hest
ID
U is
20m
The ID
U to the n
eare
st
bra
nch
join
t is
15m
Leve
l diff
ere
nce
betw
een ID
U a
nd O
DU
is 3
0m
Leve
l diff
ere
nce
betw
een ID
Us
is 8
m
1 Total pipe length is equal to all the liquid pipe or all the gas pipe length.
2 When the total equivalent pipe length of liquid side plus gas side is more than 90m,
it needs to meet the specic conditions according to the installation part of the technical manual.
Permitted value(m)
Total piping length (Actual)
Longest piping (L)
Piping length
Level difference
Level difference between IDU~IDU
Level difference between IDU~ODU
Equivalent piping length (from the farthest IDU to the rst indoor branch joint)
7.2/9.2/11kW
100m
45m
50m
20m
30m
20m
8m
14.5/17kW
100m
60m
70m
20m
30m
20m
8m
Outdoor unit up
Outdoor unit down
Equivalent length
Actual length
Easy installation: No special area is required for outdoor units.
Easy transportaion: All outdoor units can be transported by elevator,
which greatly simplies installation and reduces time and labor.
The Mini VRF system's indoor and outdoor units are almost as easy to
install as residential airconditioning systems, making them ideal for
small ofces and shops.
Easy to transportEasy Installation
Moto
r sp
eed(R
PM
)
System pressure
DC inverter stepless adjustment
AC inverter multistep adjustment
200
400
600
800850
EER4.47
9.2kW
4.39
7.2kW
4.00
11kW
4.06
14.5kW
4.26
17kW
4.54.03.53.02.52.01.51.00.50.0
High Efficiency Heat Exchanger
difference