6
EverGuard ® Extreme Brochure (COMEG154) Updated: 1/16

EverGuard Extreme Brochure - GAF.comEverGuard® Extreme Brochure (COMEG154) Updated: 1/16 U.S. Bank Building, Boise, Idaho 80 mil EverGuard Extreme® TPO gaf.com Advanced Protection

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EverGuard Extreme Brochure - GAF.comEverGuard® Extreme Brochure (COMEG154) Updated: 1/16 U.S. Bank Building, Boise, Idaho 80 mil EverGuard Extreme® TPO gaf.com Advanced Protection

EverGuard® Extreme Brochure (COMEG154)

Updated: 1/16

Page 2: EverGuard Extreme Brochure - GAF.comEverGuard® Extreme Brochure (COMEG154) Updated: 1/16 U.S. Bank Building, Boise, Idaho 80 mil EverGuard Extreme® TPO gaf.com Advanced Protection

U.S. Bank Building, Boise, Idaho

80 mil EverGuard Extreme® TPO

gaf.com

Advanced Protection For Your Property —Only From GAF!

Advanced Heat & UV Protection TPO

Advanced Protection™ TPO

Page 3: EverGuard Extreme Brochure - GAF.comEverGuard® Extreme Brochure (COMEG154) Updated: 1/16 U.S. Bank Building, Boise, Idaho 80 mil EverGuard Extreme® TPO gaf.com Advanced Protection

Get Advanced Protection™ TPO For Your Property...Only From GAF!GAF EverGuard Extreme® Advanced Protection™ TPO is the best-performing TPO you can buy for your property. Its patent-pending technology not only results in next-generation performance against heat aging and UV degradation (the two key performance characteristics directly related to roof system longevity), but also exceeds all key ASTM standards for TPO membranes. Why settle for anything less when you can get the advanced protection of EverGuard Extreme® TPO for your property? Check out tporesults.com for the results of the largest independent TPO study ever done.

EverGuard Extreme® TPO Far Exceeds The Performance Of Typical TPO MembranesOther TPO roofing sold today simply cannot match the performance of EverGuard Extreme®. It uses a proprietary formulation of stabilizers and UV absorbers to achieve performance levels far beyond current roofing standards. To prove it, we tested EverGuard Extreme® TPO against typical TPO membranes for the two key performance attributes most highly sought after in TPO membranes: heat aging and UV weathering. The results were astounding— which is why we back EverGuard Extreme® with the industry’s best guarantees: up to 35 years!

Da

ys t

o C

ap C

rack

s w

/28

0°F

(137.

8°C

)/O

ven A

gin

g

lbf

0

25

50

75

100

125

150

175

200

Compe

titor A60

mil

Compe

titor A80

mil

Compe

titor B60

mil

Compe

titor B80

mil

Compe

titor C60

mil

Compe

titor C80

mil

Ever

Guard

Extre

me®

60 m

il

Ever

Guard

Extre

me®

80 m

il

ASTM M

inimum

Ever

Guard

Extre

me® TP

O

Per

form

ance

Ver

sus

AST

M S

tand

ard

, X

Min

imum

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

EverGuard Extreme® TPO vs. Standard TPO Membranes In ASTM D6878 Accelerated Weathering Tests...

Compe

titor A60

mil

Compe

titor A80

mil

Compe

titor B60

mil

Compe

titor B80

mil

Compe

titor C60

mil

Compe

titor C80

mil

Ever

Guard

Extre

me®

60 m

il

Ever

Guard

Extre

me®

80 m

il

0

25

50

75

100

125

150

%

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0

5

10

15

20

25

30

%

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0.00

0.25

0.50

0.75

1.00

lbf

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0

50

100

150

200

250

300

350

400

EverGuard Extreme® TPO vs. Standard TPO MembranesIn 280ºF (137.8ºC) Heat-Aging Tests...

(lower is better)

EverGuard Extreme® TPO Has More Than Double The Performance Of Standard TPO Membranes In Heat-Aging Tests...Why is this important? Because heat can severely degrade standard TPO membranes over time. So we tested EverGuard Extreme® TPO against the three leading TPO membranes at 280°F (137.8°C)—a temperature beyond the most rigorous proposed ASTM tests. As you can see in the chart (and the unretouched photos below), EverGuard Extreme® TPO significantly outperformed the competition when exposed to damaging heat.

EverGuard Extreme® TPO (top of membrane)

Competitor’s TPO (top of membrane)

EverGuard Extreme® TPO (bottom of membrane)

Competitor’s TPO (bottom of membrane)

Even after the most severe accelerated heat aging at 280ºF (137.8°C), EverGuard Extreme® TPO still looks brand new!

But, a leading competitor’s standard TPO shows severe deterioration on both the top and bottom of the membrane.

See The Proof...

Plus, EverGuard Extreme® TPO Exceeds All Of The Performance Standards Of ASTM D6878...Not only does EverGuard Extreme® TPO exceed the weathering and heat-aging standards of D6878, but its performance in all of the other critical performance measures far exceeds the minimum requirements—in most cases by more than double.

More than double the seam strength... for a long-lasting, water-tight roof.

Da

ys t

o C

ap C

rack

s w

/28

0°F

(137.

8°C

)/O

ven A

gin

g

lbf

0

25

50

75

100

125

150

175

200

Compe

titor A60

mil

Compe

titor A80

mil

Compe

titor B60

mil

Compe

titor B80

mil

Compe

titor C60

mil

Compe

titor C80

mil

Ever

Guard

Extre

me®

60 m

il

Ever

Guard

Extre

me®

80 m

il

ASTM M

inimum

Ever

Guard

Extre

me® TP

O

Per

form

ance

Ver

sus

AST

M S

tand

ard

, X

Min

imum

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

EverGuard Extreme® TPO vs. Standard TPO Membranes In ASTM D6878 Accelerated Weathering Tests...

Compe

titor A60

mil

Compe

titor A80

mil

Compe

titor B60

mil

Compe

titor B80

mil

Compe

titor C60

mil

Compe

titor C80

mil

Ever

Guard

Extre

me®

60 m

il

Ever

Guard

Extre

me®

80 m

il

0

25

50

75

100

125

150

%

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0

5

10

15

20

25

30

%

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0.00

0.25

0.50

0.75

1.00

lbf

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0

50

100

150

200

250

300

350

400

EverGuard Extreme® TPO vs. Standard TPO MembranesIn 280ºF (137.8ºC) Heat-Aging Tests...

(lower is better)

Da

ys t

o C

ap C

rack

s w

/28

0°F

(137.

8°C

)/O

ven A

gin

g

lbf

0

25

50

75

100

125

150

175

200

Compe

titor A60

mil

Compe

titor A80

mil

Compe

titor B60

mil

Compe

titor B80

mil

Compe

titor C60

mil

Compe

titor C80

mil

Ever

Guard

Extre

me®

60 m

il

Ever

Guard

Extre

me®

80 m

il

ASTM M

inimum

Ever

Guard

Extre

me® TP

O

Per

form

ance

Ver

sus

AST

M S

tand

ard

, X

Min

imum

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

EverGuard Extreme® TPO vs. Standard TPO Membranes In ASTM D6878 Accelerated Weathering Tests...

Compe

titor A60

mil

Compe

titor A80

mil

Compe

titor B60

mil

Compe

titor B80

mil

Compe

titor C60

mil

Compe

titor C80

mil

Ever

Guard

Extre

me®

60 m

il

Ever

Guard

Extre

me®

80 m

il

0

25

50

75

100

125

150

%

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0

5

10

15

20

25

30

%

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0.00

0.25

0.50

0.75

1.00

lbf

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0

50

100

150

200

250

300

350

400

EverGuard Extreme® TPO vs. Standard TPO MembranesIn 280ºF (137.8ºC) Heat-Aging Tests...

(lower is better)

More than double the elongation... to resist splitting and tearing.

Da

ys t

o C

ap C

rack

s w

/28

0°F

(137.

8°C

)/O

ven A

gin

g

lbf

0

25

50

75

100

125

150

175

200

Compe

titor A60

mil

Compe

titor A80

mil

Compe

titor B60

mil

Compe

titor B80

mil

Compe

titor C60

mil

Compe

titor C80

mil

Ever

Guard

Extre

me®

60 m

il

Ever

Guard

Extre

me®

80 m

il

ASTM M

inimum

Ever

Guard

Extre

me® TP

O

Per

form

ance

Ver

sus

AST

M S

tand

ard

, X

Min

imum

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

EverGuard Extreme® TPO vs. Standard TPO Membranes In ASTM D6878 Accelerated Weathering Tests...

Compe

titor A60

mil

Compe

titor A80

mil

Compe

titor B60

mil

Compe

titor B80

mil

Compe

titor C60

mil

Compe

titor C80

mil

Ever

Guard

Extre

me®

60 m

il

Ever

Guard

Extre

me®

80 m

il

0

25

50

75

100

125

150

%

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0

5

10

15

20

25

30

%

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0.00

0.25

0.50

0.75

1.00

lbf

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0

50

100

150

200

250

300

350

400

EverGuard Extreme® TPO vs. Standard TPO MembranesIn 280ºF (137.8ºC) Heat-Aging Tests...

(lower is better)

More than double the dimensional stability...to minimize the damaging effects of freeze/thaw.

Da

ys t

o C

ap C

rack

s w

/28

0°F

(137.

8°C

)/O

ven A

gin

g

lbf

0

25

50

75

100

125

150

175

200

Compe

titor A60

mil

Compe

titor A80

mil

Compe

titor B60

mil

Compe

titor B80

mil

Compe

titor C60

mil

Compe

titor C80

mil

Ever

Guard

Extre

me®

60 m

il

Ever

Guard

Extre

me®

80 m

il

ASTM M

inimum

Ever

Guard

Extre

me® TP

O

Per

form

ance

Ver

sus

AST

M S

tand

ard

, X

Min

imum

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

EverGuard Extreme® TPO vs. Standard TPO Membranes In ASTM D6878 Accelerated Weathering Tests...

Compe

titor A60

mil

Compe

titor A80

mil

Compe

titor B60

mil

Compe

titor B80

mil

Compe

titor C60

mil

Compe

titor C80

mil

Ever

Guard

Extre

me®

60 m

il

Ever

Guard

Extre

me®

80 m

il

0

25

50

75

100

125

150

%

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0

5

10

15

20

25

30

%

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0.00

0.25

0.50

0.75

1.00

lbf

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0

50

100

150

200

250

300

350

400

EverGuard Extreme® TPO vs. Standard TPO MembranesIn 280ºF (137.8ºC) Heat-Aging Tests...

(lower is better)

Nearly double the breaking strength...to resist wind uplift and roof blow-off.

Atlas Ultra Accelerated Weathering System

Da

ys t

o C

ap C

rack

s w

/28

0°F

(137.

8°C

)/O

ven A

gin

g

lbf

0

25

50

75

100

125

150

175

200

Compe

titor A60

mil

Compe

titor A80

mil

Compe

titor B60

mil

Compe

titor B80

mil

Compe

titor C60

mil

Compe

titor C80

mil

Ever

Guard

Extre

me®

60 m

il

Ever

Guard

Extre

me®

80 m

il

ASTM M

inimum

Ever

Guard

Extre

me® TP

O

Per

form

ance

Ver

sus

AST

M S

tand

ard

, X

Min

imum

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

4.5

5.0

EverGuard Extreme® TPO vs. Standard TPO Membranes In ASTM D6878 Accelerated Weathering Tests...

Compe

titor A60

mil

Compe

titor A80

mil

Compe

titor B60

mil

Compe

titor B80

mil

Compe

titor C60

mil

Compe

titor C80

mil

Ever

Guard

Extre

me®

60 m

il

Ever

Guard

Extre

me®

80 m

il

0

25

50

75

100

125

150

%

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0

5

10

15

20

25

30

%

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0.00

0.25

0.50

0.75

1.00

lbf

ASTM M

inimum

Ever

Guard

Extre

me® TP

O0

50

100

150

200

250

300

350

400

EverGuard Extreme® TPO vs. Standard TPO MembranesIn 280ºF (137.8ºC) Heat-Aging Tests...

(lower is better)

EverGuard Extreme® TPO Far Exceeds Typical TPO Membranes In UV Weathering Tests...Based on the ASTM D6878 Xenon Arc Weatherometer testing method, EverGuard Extreme® TPO far exceeds the performance of typical TPO membranes—more than double in most cases. Why is that important? Because the ASTM weathering test is a proxy for how well the membrane will stand up to the long-term ravages of UV degradation, the key destroyer of long-term TPO membrane performance.

We Even Tested EverGuard Extreme® TPO Using The Most Severe Testing Method We Know...The Atlas Ultra Accelerated Weathering System (UAWS) is the ultimate test for TPO membranes because it combines concentrated UV, heat, and light into one torturous test. Even under these ultra-extreme conditions, EverGuard Extreme® TPO lasted over 265 days—the equivalent of over 45 years in the harsh climate of southern Florida. Imagine how long it would last on your roof!

UP TO

35YR.GUARANTEE*

* See EverGuard® Diamond Pledge™ NDL Roof Guarantee for complete coverage and restrictions.

Page 4: EverGuard Extreme Brochure - GAF.comEverGuard® Extreme Brochure (COMEG154) Updated: 1/16 U.S. Bank Building, Boise, Idaho 80 mil EverGuard Extreme® TPO gaf.com Advanced Protection

EverGuard Extreme® Advanced Protection™ TPO Offers The Best Guarantees In The Industry:

EverGuard Extreme® TPO Physical Properties Far Exceed ASTM Standards!

EverGuard Extreme® Product/Installation Method

Guarantee Length* Special Comments

50 mil (mechanically attached) 20 yrs. Use 50 mil EverGuard Extreme® TPO to replace competitive brands’ 60 mil TPO

50 mil (fully adhered) 60 mil (mechanically attached) 25 yrs.

60 mil (fully adhered) 70 mil (all) 80 mil (mechanically attached)

30 yrs. Use 70 mil EverGuard Extreme® TPO to replace competitive brands’ 80 mil TPO

80 mil (fully adhered) 35 yrs.

* See EverGuard® Diamond Pledge™ NDL Roof Guarantee for complete coverage and restrictions. Not eligible for WellRoof® Guarantee Extension. Note: Systems using the RhinoBond® attachment method qualify as fully adhered.

* This chart represents EverGuard Extreme® TPO 60 mil. See gaf.com for other mil thicknesses.

EverGuard Extreme®

Advanced Protection™ TPO Specs1. EverGuard Extreme® TPO Reinforced Membrane

2. EverGuard®-Approved Bonding Adhesive

3. EnergyGuard™ High Density Cover Board

4. GAF Drill-Tec™ Insulation Fasteners and Plates

5. EnergyGuard™ Insulation

6. Approved Roof Deck

1

5

2

3

46

Physical Properties ASTM Test Method ASTM D6878 Minimum EverGuard Extreme® TPO Typical Test Data

1. Certain data is provided in MD (machine direction) x CMD (cross machine direction) format. 2. Data is based upon typical product performance, and is subject to normal manufacturing tolerance and variance.

Nominal Thickness ASTM D751 0.039” (0.99 mm) (min.) 0.060” (1.52 mm)*0.050” (1.27 mm), 0.070” (1.78 mm), 0.080” (2.03 mm) @gaf.com

Breaking Strength ASTM D751 Grab Method 220 lbf/in. (38.5 Kn/m) 305 lbf x 290 lbf (454 x 432 kg/m)

Factory Seam Strength ASTM D751 66 lbf (98.34 kg/m) 150 lbf (223.5 kg/m) (membrane failure)

Elongation at Break ASTM D751 15% 30%

Heat Aging ASTM D573 90% Retention of Breaking Strength and Elongation at Break

100%

Tear Strength ASTM D751 8” x 8” (203 x 203 mm) Sample

55 lbf (81.95 kg/m) 65 lbf x 130 lbf (96.85 x 193.7 kg/m)

Puncture Resistance FTM 101C Method 2031 Not Established 380 lbs. (172 kg)

Cold Brittleness ASTM D2137 –40°C –40°C

Permeance ASTM E96 Not Established 0.08 Perms

Dimensional Change ASTM D1204 @158°F (70°C), 6 hrs. +/- 1% 0.4%

Water Absorption ASTM D471 @158°F (70°C), 1 week +/- 3% (top coating only) 0.7%

Hydrostatic Resistance ASTM D751 Method D Not Established 430 psi

Ozone Resistance ASTM D1149 No visible deterioration @ 7x magnification

No visible deterioration @ 7x magnification

Reflectivity (white) initial/aged ASTM C1549 N/A 0.835/0.72

Emissivity (white) initial/aged ASTM C1371 N/A 0.84/0.91

Weather Resistance ASTM G155/D6878, 80°C BPT, 50°C chamber air temp., no cracks and crazing observed when the exposed specimen wrapped around a 3” (76 mm) mandrel and inspected @ 7x magnification

10,080 KJ/(m2 . nm) at 340 nm >46,000 KJ/(m2 . nm) at 340 nm

Typical Application

The EverGuard® Diamond Pledge™ NDL Roof Guarantee Is Your Best Choice—And There’s No Exclusion For Ponding Water!

50 mil & 70 mil EverGuard Extreme®: Your “Everyday” Choices In TPOGAF’s 50 mil and 70 mil versions of EverGuard Extreme® Advanced Protection™ TPO have virtually identical weathering characteristics as our 60 mil and 80 mil versions.

What does that mean for you? 50 mil EverGuard Extreme® TPO offers excellent performance to typical 60 mil TPO—but for virtually the same price! The same is true for 70 mil EverGuard Extreme® TPO, which is similar in price to typical 80 mil TPO, but with excellent performance.

With EverGuard Extreme® TPO, you’ll never have to choose between performance and price— you’ll get both. And with our 50 mil and 70 mil versions, you’ll have more design choices than ever. So why use anything else?

IKEA Distribution CenterBaltimore, Maryland 60 mil EverGuard Extreme® TPO

Page 5: EverGuard Extreme Brochure - GAF.comEverGuard® Extreme Brochure (COMEG154) Updated: 1/16 U.S. Bank Building, Boise, Idaho 80 mil EverGuard Extreme® TPO gaf.com Advanced Protection

Use EverGuard Extreme® TPO Prefabricated Accessories For A Reliable, Watertight Roofing System

Field fabrication of TPO accessories is time-consuming, costly, and inconsistent, and can lead to unreliable details that compromise a watertight roofing system.

EverGuard® TPO prefabricated accessories deliver consistent quality and eliminate the worry and problems often associated with field fabrication. They can also boost productivity up to 200%,* while reducing installed cost by up to 12% when compared to field-fabricating details.

SCUPPERTPO can be heat welded to the scupper, for a strong, secure installation

SQUARE TUBE WRAPTube wraps are split with overlap to wrap around square or rectangular tubing; ensures a solid weld

INSIDE CORNERManufactured to accommodate inside corners of base and curb flashings

CORNER CURB WRAPFour standard sizes to flash curbs that are 24", 36", 48", and 60" (609.6, 914.4, 1,219.20, and 1,524 mm) in size

UNIVERSAL CORNERAccommodates both inside and outside corners of base and curb flashings

POURABLE SEALER POCKETStructural foundation for EverGuard® Pourable Sealant

YELLOW SAFETY TAPE Provides a warning to take caution around potential roof hazards

VENTLimits air flow to one direction, avoiding moisture buildup

TPO DRAINTPO can be heat welded directly to the drain body, for secure installation

PREFORMED SPLIT PIPE BOOTThree standard sizes accommodate most pipes and conduits

PREFORMED VENT BOOTAccommodates most common pipes and conduits from 1" to 6" (25.4 to 152.4 mm)

WALKWAY ROLLHeat welds directly to TPO membrane or installed with seam tape; available in gray and yellow

T-JOINT COVER PATCHESConforming seal for use over T-joints in 60 and 80 mil membrane applications

FLUTED CORNERFor use in flashing outside corners of base and curb flashings

* Based on GAF estimate to field-fabricate flashing details.

Page 6: EverGuard Extreme Brochure - GAF.comEverGuard® Extreme Brochure (COMEG154) Updated: 1/16 U.S. Bank Building, Boise, Idaho 80 mil EverGuard Extreme® TPO gaf.com Advanced Protection

©2016 GAF 1/16 • #702 • gaf.com • 1 Campus Drive, Parsippany, NJ 07054 COMEG154

EverGuard Extreme® Is Now Your “Everyday Choice” In TPO Roofing...

* Must be installed within 10 years of original roof installation. See EverGuard® Diamond Pledge™ NDL Roof Guarantee for complete coverage and restrictions. NDL guarantees greater than 25 years are not eligible for WellRoof ® Guarantee Extension.

If you’re considering a TPO roof for your property, EverGuard Extreme® Advanced Protection™ TPO is your best choice.

Solar InstallationsThe temperature under building-integrated photovoltaics (BIPV) can reach as high as 190˚F (87.8˚C). Standard TPO formulations can fail in accelerated heat-aging studies in as little as 40 days—the equivalent of less than 15 years in actual use. Without the enhanced UV and heat-protection package in EverGuard Extreme® TPO, your expensive BIPV roof may be subject to premature failure. And removing BIPV to repair or replace a failed roofing membrane is very expensive.

Even if you’re not ready to install BIPV today, an EverGuard Extreme® system allows you to install a high-performance, long-term guaranteed (up to 35 years) TPO roof today—and defer the expense of a solar system to a later date, without guarantee disruption!*

Vegetative RoofingAs vegetative roofs become more popular, you may some day consider adding one to your existing roofing system. With EverGuard Extreme® TPO, you can install the roof today and defer the expense of a vegetative system to a later date, without guarantee disruption!*

Replacing Standard TPOWhy use standard TPO on your property when you can get the incredible performance and protection of EverGuard Extreme® TPO? In the past, upgrading a standard 60 mil TPO with 60 mil EverGuard Extreme® TPO typically meant an increase in your roofing cost. But now, you can replace 60 mil standard TPO with our new 50 mil EverGuard Extreme® TPO— so you’ll get better protection for about the same price!

High-Heat ApplicationsThe sun’s rays can be reflected and magnified off nearby buildings’ windows, causing increased heat loads on your property’s TPO roof. They can also be reflected from your roof’s parapet walls or other reflective surfaces onto the roof. Either or both conditions can result in premature aging of your roof. But not with EverGuard Extreme® TPO. Its proprietary formulation is designed to handle these high-heat applications with ease.

Valuable Property ApplicationsWhen you’re protecting valuable property such as expensive equipment or product inventory, or when you just can’t risk roofing failure, you need the peace of mind that an EverGuard Extreme® TPO roof can give. With the best guarantees in the industry, you can trust that your EverGuard Extreme® roof will protect your building and its contents.

GA

F IS

100% AMERICAN OW

NED

CREATING AMERICAN J

OBS!

M

ADE IN AMERICA

CR

EAT ING A MER ICAN J

OB

S