3
rev description Rev date checked C:\Users\user\Desktop\PROJECTS\20014 Fraser Residence\1. Architectural\Archicad\20014 fraser TP.pln - 13/07/20 NOT FOR CONSTRUCTION 1 / 3 A NOTING OF PICKET FENCING 13/07/20 DM N DRAWN BY : PROPOSED RESIDENCE LOT 1/190 GRIFFITHS STREET PORT FAIRY 3284 C & K FRASER PROJECT : CLIENT : SITE ADDRESS : DESIGNED BY : PROJECT NO. DRAWING NO. ISSUE : PLANNING APPLICATION DONNA MONAGHAN DONNA MONAGHAN © Copyright Reserved - Form & Function Building Design 20014 ISSUE DATE : 13/07/20 SHEET SIZE : A1 ABN 88 330 502 484 BPB DP-AD 24956 General Notes 1. The Builder shall check all dimensions and levels on site prior to construction. 2. Notify any errors, discrepancies or omissions to the Building Designer. 3. Drawings shall not be used for construction purposes until issued for construction. 4. All works must be executed in a workman like manner and all materials must conform to current Australian Standard codes. 5. These plans are to be read in conjunction with project specifications, relevant reports, engineering and soil testing where indicated. 5. Written dimensions take precedence over scaled dimensions. 853 RAGLAN PARADE WARRNAMBOOL 3280 T | (03) 5561 1099 M | 0437 611 199 E | [email protected] W | www.formandfunction.net.au site area (m2) 456.89 proposed areas analysis first floor ground floor garage deck balcony portico 154.46 121.81 44.02 26.60 14.99 3.86 365.74 m² site coverage building footprint deck garage footprint 154.46 26.60 18.64 199.70 m² hard surface areas ground floor garage 121.81 44.02 165.83 m² garden area (m2) 218.60 1 0 0 . 6 2 m 1 2 4 ° 2 2 2 0 1.83m 35° 55 ’20” 100.75m 302° 38’20” 3.00 4.0 5.00 6.00 8.00 8.00 7.00 6.00 +2.10 + 2 . 4 0 2.00 2.80 2.60 2.40 3.20 3.40 7.00 3.80 3 .60 existing trees to be removed E-2 E-1 A-1 A-1 - footway driveway s.p.o.s. s.p.o.s. two storey dwelling two storey dwelling two storey dwelling balcony balcony garage water tank existing bitumen driveway existing gravel driveway griffiths street p o s t a n d h o r i z o n t a l b o a r d f e n c e No. 188 No. 4/192 sewer pit No. 194 carriageway easement existing gravel crossover power pole single storey dwelling open grass area existing vegetation to be removed 16.46 m 35° 55 ’20” No. 190 power pole (to be removed) 15.24 m 215 ° 55’20” 1 0 0 . 6 2 m 1 2 4 ° 2 2 2 0 72.20m 302° 38’20” 28.55m 302° 38’20” 1.83m 35° 55 ’20” 2 8 . 5 1 m 1 2 4 ° 2 2 2 0 2,170 2,670 4,535 7,635 2,985 3.00 4.0 5.00 6.00 8.00 8.00 7.00 6.00 +2.30 +2.10 + 2 . 4 0 2.00 2.80 2.40 7.00 3.80 3.60 E-2 E-1 A-1 E-3 A-1 - footway proposed driveway (permeable) proposed dwelling balcony driveway s.p.o.s. s.p.o.s. service yard (permeable) deck propose d 1,800 high pic ket fenc e two storey dwelling two storey dwelling two storey dwelling balcony balcony garage water tank existing bitumen driveway existing gravel driveway griffiths street No. 2/190 No. 188 No. 4/192 sewer pit No. 194 p r o p os ed 1 , 8 0 0 h i g h p i ck et f en c e gate up up up up carriageway easement existing gravel crossover power pole single storey dwelling open grass area proposed hedge 16.46 m 35° 55’20” No. 1/190 site area: 457m 2 15.60 m 215 ° 55 ’ 0” existing site plan scale 1:200 proposed site plan scale 1:200 No. 192 Griffiths Street street view of subject site - 1/190 Griffiths Street existing driveway to access Lot 2 of 190 Giffiths Street view of existing dwelling on 2/190 Griffiths Street No. 188 Griffiths Street 34% 44% 36% 48%

existing site plan - moyne.vic.gov.au...2020-8-25 · BPB DP-AD 24956 General Notes 1. The Builder shall check all dimensions and levels on site prior to construction. 2. Notify

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: existing site plan - moyne.vic.gov.au...2020-8-25 · BPB DP-AD 24956 General Notes 1. The Builder shall check all dimensions and levels on site prior to construction. 2. Notify

rev description Rev date checked

C:\Users\user\Desktop\PROJECTS\20014 Fraser Residence\1. Architectural\Archicad\20014 fraser TP.pln - 13/07/20

NOT FOR

CONSTRUCTION

1 / 3A NOTING OF PICKET FENCING 13/07/20 DM

N DRAWN BY :

PROPOSED RESIDENCELOT 1/190 GRIFFITHS

STREET PORT FAIRY 3284

C & K FRASER

PROJECT :

CLIENT :

SITE ADDRESS : DESIGNED BY :

PROJECT NO.

DRAWING NO.

ISSUE :

PLANNING APPLICATION

DONNA MONAGHAN

DONNA MONAGHAN

© Copyright Reserved - Form & Function Building Design

20014

ISSUE DATE :

13/07/20

SHEET SIZE :

A1

ABN 88 330 502 484

BPB DP-AD 24956

General Notes

1. The Builder shall check all dimensions and levels on site prior to

construction.

2. Notify any errors, discrepancies or omissions to the Building Designer.

3. Drawings shall not be used for construction purposes until issued for

construction.

4. All works must be executed in a workman like manner and all

materials must conform to current Australian Standard codes.

5. These plans are to be read in conjunction with project specifications,

relevant reports, engineering and soil testing where indicated.

5. Written dimensions take precedence over scaled dimensions.

853 RAGLAN PARADE WARRNAMBOOL 3280

T | (03) 5561 1099

M | 0437 611 199

E | [email protected]

W | www.formandfunction.net.au

site area (m2)

456.89

proposed areas analysis

first floor

ground floor

garage

deck

balcony

portico

154.46

121.81

44.02

26.60

14.99

3.86

365.74 m²

site coverage

building footprint

deck

garage footprint

154.46

26.60

18.64

199.70 m²

hard surface areas

ground floor

garage

121.81

44.02

165.83 m²

garden area (m2)

218.60

100.62m124° 22’20”

1.8

3m

35

° 55’2

0”

100.75m

302° 38’20”

3.0

0

4.0

5.0

0

6.0

0

8.0

0

8.0

0

7.0

0

6.0

0

+2.10

+2.40

2.00

2.8

0

2.6

0

2.4

0

3.2

0 3.40

7.0

0

3.80

3.60

existing trees to be removed

E-2

E-1

A-1

A-1 - footway

driveway

s.p.o.s.

s.p.o.s.

two storeydwelling

two storeydwelling

two storeydwelling

balcony

ba

lco

ny

garage

watertank

existingbitumendriveway

existing graveldriveway

griff

ith

s st

ree

t

post and horizontalboard fence

No. 188

No. 4/192sewer pit

No. 194

carriagewayeasement

existing gravelcrossover

pow

erpo

le

single storeydwelling

open grassarea

existing vegetation

to be removed

16.4

6m

35°

55’2

0”

No. 190

pow

er

pole

(to b

ere

mo

ved

)

15.2

4m

215°

55’ 2

0”

100.62m124° 22’20”

72.20m

302° 38’20”

28.55m

302° 38’20”

1.8

3m

35

° 55’2

0”

28.51m124° 22’20”

2,170

2,670

4,535

7,6

35

2,9

85

3.0

0

4.0

5.0

0

6.0

0

8.0

0

8.0

0

7.0

0

6.0

0

+2.30

+2.10

+2.40

2.00

2.8

0

2.4

0

7.0

0

3.80

3.60

E-2

E-1

A-1

E-3

A-1 - footway

proposeddriveway(permeable)

proposeddwelling

balcony

driveway

s.p.o.s.

s.p.o.s.

serviceyard

(permeable)

deck

pro

po

sed

1,8

00

hig

hp

icke

tfe

nc

e

two storeydwelling

two storeydwelling

two storeydwelling

balcony

ba

lco

ny

garage

watertank

existingbitumendriveway

existing graveldriveway

griff

ith

s st

ree

t

No. 2/190

No. 188

No. 4/192sewer pit

No. 194

proposed 1,800high picket fence

ga

te

upup

up

up

carriagewayeasement

existing gravelcrossover

pow

erpo

le

single storeydwelling

open grassarea

pro

po

sed

he

dg

e

16.4

6m

35

° 55

’20

No. 1/190site area: 457m2

15.6

0m

215°

55’

0”

existing site planscale 1:200

proposed site planscale 1:200

No. 192 Griffiths Street

street view of subject site - 1/190 Griffiths Street

existing driveway to access Lot 2 of 190 Giffiths Street

view of existing dwelling on 2/190 Griffiths Street

No. 188 Griffiths Street

34%

44%

36%

48%

Page 2: existing site plan - moyne.vic.gov.au...2020-8-25 · BPB DP-AD 24956 General Notes 1. The Builder shall check all dimensions and levels on site prior to construction. 2. Notify

rev description Rev date checked

C:\Users\user\Desktop\PROJECTS\20014 Fraser Residence\1. Architectural\Archicad\20014 fraser TP.pln - 13/07/20

NOT FOR

CONSTRUCTION

2 / 3A NOTING OF PICKET FENCING 13/07/20 DM

N DRAWN BY :

PROPOSED RESIDENCELOT 1/190 GRIFFITHS

STREET PORT FAIRY 3284

C & K FRASER

PROJECT :

CLIENT :

SITE ADDRESS : DESIGNED BY :

PROJECT NO.

DRAWING NO.

ISSUE :

PLANNING APPLICATION

DONNA MONAGHAN

DONNA MONAGHAN

© Copyright Reserved - Form & Function Building Design

20014

ISSUE DATE :

13/07/20

SHEET SIZE :

A1

ABN 88 330 502 484

BPB DP-AD 24956

General Notes

1. The Builder shall check all dimensions and levels on site prior to

construction.

2. Notify any errors, discrepancies or omissions to the Building Designer.

3. Drawings shall not be used for construction purposes until issued for

construction.

4. All works must be executed in a workman like manner and all

materials must conform to current Australian Standard codes.

5. These plans are to be read in conjunction with project specifications,

relevant reports, engineering and soil testing where indicated.

5. Written dimensions take precedence over scaled dimensions.

853 RAGLAN PARADE WARRNAMBOOL 3280

T | (03) 5561 1099

M | 0437 611 199

E | [email protected]

W | www.formandfunction.net.au

ground floor living area121.81 m2 / 13.0 sqrs

28.55m

302° 38’20”

1. 8

3m

35

° 55’ 2

0”

1

2

3

4

5

6

7

8

9

10

11

2

3

4

5

1 2

1

2

3

4

5

DW

28.51m

124° 22’20”

F

8,6

80

2,0

00

1,4

10

6,1801,20014,080

12,2902,5806,590

6,6

80

2,0

00

4,5605,390750

+3.30

+3.15

+2.61

+2.58

+2.40

1,800 high white painted timber picket

fence. pickets to be spaced 50mm apart

and be raised off the ground 150mm in

accordance with GHCMA requirements

carriageway easement

laundrypwdr

pantry

kitchen

meals

living

double garage

entry

front

portico

rear

portico

deck

private yard

driveway

stair

full heightsliding door

full heightsliding door

1

up

up

up gate

1800 high picket fence

pro

po

sed

he

dg

e

service yard

binstoragearea

low retaining wall

clothesline

1 3

3

4

up

wmdryer

she

lve

s

co

ats

up

storageunderstair

services easement

pergola

up

12

2

storage

coastal nativelandcaping

1,8

00 p

icke

tfe

nc

e a

nd

ga

te

18

00 h

igh

pic

ke

t f e

nc

e

180

0 h

igh

pic

ke

t fe

nc

e

16. 4

6m

35

° 55

’ 20

15

. 60

m21

55

’ 0”

first floor living area154.46 m2 / 15.9 sqrs

5

6

7

8

9

10

11

12

13

14

15

16

18,6702,790setback fromground floor

8,6

80

2,0

00

2,0

00

6,6

80

8,6

80

14,8703,800

7,495

+6.30

+6.15

bed 1

bed 2

bed 4retreat

bathwc

ensuite

trtr

rob

e

balcony

down

stair

1000 high balustrade

wir

bed 3

rob

e

wir

fixed external louvre

slid

ing

exte

rna

l lo

uv

resl

idin

g e

xte

rna

l lo

uv

re

velux windows

flu

e

study

rob

e

glassdoor

store

ground floor planscale 1:100

first floor planscale 1:100

north perspectivescale 1:220.62

west perspectivescale 1:220.62

aerial photo

north east perspective south perspectivescale 1:220.62

proposed shed on neighbouring site

(not part of this application)

Page 3: existing site plan - moyne.vic.gov.au...2020-8-25 · BPB DP-AD 24956 General Notes 1. The Builder shall check all dimensions and levels on site prior to construction. 2. Notify

rev description Rev date checked

C:\Users\user\Desktop\PROJECTS\20014 Fraser Residence\1. Architectural\Archicad\20014 fraser TP.pln - 13/07/20

NOT FOR

CONSTRUCTION

3 / 3A NOTING OF PICKET FENCING 13/07/20 DM

N DRAWN BY :

PROPOSED RESIDENCELOT 1/190 GRIFFITHS

STREET PORT FAIRY 3284

C & K FRASER

PROJECT :

CLIENT :

SITE ADDRESS : DESIGNED BY :

PROJECT NO.

DRAWING NO.

ISSUE :

PLANNING APPLICATION

DONNA MONAGHAN

DONNA MONAGHAN

© Copyright Reserved - Form & Function Building Design

20014

ISSUE DATE :

13/07/20

SHEET SIZE :

A1

ABN 88 330 502 484

BPB DP-AD 24956

General Notes

1. The Builder shall check all dimensions and levels on site prior to

construction.

2. Notify any errors, discrepancies or omissions to the Building Designer.

3. Drawings shall not be used for construction purposes until issued for

construction.

4. All works must be executed in a workman like manner and all

materials must conform to current Australian Standard codes.

5. These plans are to be read in conjunction with project specifications,

relevant reports, engineering and soil testing where indicated.

5. Written dimensions take precedence over scaled dimensions.

853 RAGLAN PARADE WARRNAMBOOL 3280

T | (03) 5561 1099

M | 0437 611 199

E | [email protected]

W | www.formandfunction.net.au

900

2,7

00

300

1,8

00

1,8

00

1,8

00

2,790

proposed shed on lot 2(not part of this application)

proposed dwelling on lot 1

7,3

00 b

uild

ing

he

igh

t

3,5

00

50min.

150max.

150

painted white vertical groove cladding

garage door with cladding

to match dwelling

120 dia white powder

coated steel columns

Regulation 79 side

setback requirement

white powder coated

aluminium windows

white powder coated

steel balustrade

1,800 high white painted timber

picket fence. pickets to be spaced

50mm apart and be raised off the

ground 150mm in accordance with

GHCMA requirements

pro

po

sed

bo

un

da

ry

pro

po

sed

bo

un

da

ry

ceiling level 6.000

floor level 6.300

floor level 3.300

garage floor level 2.400

natural ground level to beexcavated

external white powder coatedsteel louvre screen

colorbond lysaght trimdek roofsheeting in 'shale grey' at 2

degree pitch

painted white vertical groovecladdding

pro

po

sed

bo

un

da

ry

1,0

00

proposed brick letterbox

external white powdercoated louvre screen

white painted timber pergola

north east elevationscale 1:100

south east elevationscale 1:100

south west elevationscale 1:100

north west elevationscale 1:100

general axonometric

proposed shed on neighbouring site

(not part of this application)