7
Experts in C he m -Feed and W ater Treatm ent Handheld Photometer for Calibration of Sensors Basics photometry Portable photometer Overview photometer – calibration - sensors DT 1 measuring ranges; DT 2 measuring ranges DT 3 handheld photometer for hydrogen peroxide DT 4 handheld photometer for chlorite

Experts in Chem-Feed and Water Treatment Handheld Photometer for Calibration of Sensors Basics photometry Portable photometer Overview photometer

Embed Size (px)

Citation preview

Page 1: Experts in Chem-Feed and Water Treatment Handheld Photometer for Calibration of Sensors  Basics photometry  Portable photometer  Overview photometer

Experts in Chem-Feed and Water Treatment

Handheld Photometer for Calibration of Sensors

Basics photometry Portable photometer Overview photometer – calibration - sensors DT 1 measuring ranges; DT 2 measuring ranges DT 3 handheld photometer for hydrogen peroxide DT 4 handheld photometer for chlorite

Page 2: Experts in Chem-Feed and Water Treatment Handheld Photometer for Calibration of Sensors  Basics photometry  Portable photometer  Overview photometer

1.1.2003 2

Experts in Chem-Feed and Water Treatment

Portable Photometer

Measuring Chamber

Cuvettes9 V Battery

reagents

Mixercuvette cleaningbrush

Displaykeypad

Page 3: Experts in Chem-Feed and Water Treatment Handheld Photometer for Calibration of Sensors  Basics photometry  Portable photometer  Overview photometer

1.1.2003 3

Experts in Chem-Feed and Water Treatment

Photometer DT 1 – measuring ranges

0.05…6.0 mg/l free chlorine (DPD 1) + total chlorine (DPD3)

0.1…13.0 mg/l bromine (DPD 1)

0.05…11 mg/l chlorine dioxide (DPD 1)

0.03…4.0 mg/l ozone (DPD 4)

pH 6.5…8.4 (phenol red tablets)

1…80 mg/l cyanuric acidPhotometer DT 2 – measuring ranges

0.05…2.0 mg/l fluoride

0.05…6.0 mg/l free chlorine and total chlorine

0.05…11.0 mg/l chlorine dioxide

Page 4: Experts in Chem-Feed and Water Treatment Handheld Photometer for Calibration of Sensors  Basics photometry  Portable photometer  Overview photometer

1.1.2003 4

Experts in Chem-Feed and Water Treatment

3

Ordering information

Photometer DT3 complete with bag: Order no. 1023143

Reagent for hydrogen peroxide, 15ml, Order no. 1023636

5 pieces round cells with cap (diameter 16 mm), Order no. 1024072

1

2

3

1

23

Photometer DT3 for Determination of H2O2

Page 5: Experts in Chem-Feed and Water Treatment Handheld Photometer for Calibration of Sensors  Basics photometry  Portable photometer  Overview photometer

1.1.2003 5

Experts in Chem-Feed and Water Treatment

3

Features/Customers Benefit

Customized measuring ranges for calibration of the H2O2-Sensor

Two measuring ranges: 1 to 50 mg/l and 40 to 500 mg/l = ppm Unique photometer for H2O2 with these measuring ranges

Simple handling and simultaneously high accuracy Simplier than extensive preparation of standard solutions More accurate, than rapid colorometric test sticks Faster than titration

DEV-based Method (Deutsche Einheitsverfahren H 15) reliable, approved method with less interferences long term stable dye; so different reading time is not critical

Photometer DT3 for Determination of H2O2

Page 6: Experts in Chem-Feed and Water Treatment Handheld Photometer for Calibration of Sensors  Basics photometry  Portable photometer  Overview photometer

1.1.2003 6

Experts in Chem-Feed and Water Treatment

3

Ordering Information Photometer DT4 complete with bag, order no. 1022695 Stirrer for stripping og chlorine dioxide, order no. 1022754 3 pieces spare cells, order no. 1007566 DPD reagent set, each bottle 15 ml, order no. 1007567 Chlorine dioxide tablets Nr.1 R 127, order no. 501317 Chlorine dioxide tablets Nr.2 R 128, order no. 501318

1

2

3

4

5

6

1

23

4

56

Photometer DT4 for Determination of Chlorite

Page 7: Experts in Chem-Feed and Water Treatment Handheld Photometer for Calibration of Sensors  Basics photometry  Portable photometer  Overview photometer

1.1.2003 7

Experts in Chem-Feed and Water Treatment

3

Features/Customer Benefits

Beside chlorite also the parameter: ClO2 and chlorine available

Customized measuring range for calibration of the chlorite-sensor Measuring range: 0.03 up to 2,5 mg/l = ppm Unique photometer for chlorite with this measuring range

Simple handling beside effectual accuracy

Simpler and more cost effective than ionchromatography Effectual accurate for calibration of the chlorite-sensors

Optimized DPD-based method for chlorite Stripping of chlorine dioxide by the help of enclosed stirrer

Photometer DT4 for Determination of Chlorite