STONEX EUROPE srl Via Cimabue 39 20851 Lissone (MB) - Italy Phone +390392783008 Fax +390392789576 www.stonexpositioning.com
Download data from Total Station to PC.docx 1
Download data from Total Station to PC
With SD memory card
1. Insert SD memory card in the Total Station
2. Press MENU key and go to page 3/4 with PAG key
3. Press F1 Data Output --> F1 Job Data
Nome Lavoro
Data: Meas.Val Meas.Val. = Export all known points
and measured points
More Job Not active function
Format .GSI .gsi = Export data format
4. Press F4 OK
5. Insert filename to assign to file on SD memory card, and press ENT key
6. Go back to main menu, and extract SD memory card
7. Insert SD memory card on PC, and run Stonex Data Manager software
8. To import data go to Menu --> Libretto --> Lettura File --> Formato GSI
NOTE: Insert and remove SD memory card only in total station main menu!
With communication cable STSSP19U (RS232 Port)
1. Connect the total station with the computer via communication cable STSSP19U (RS232 Port)
2. Check on the Total Station if internal memory for data saving is set (Menu --> F2 Parameters --> PAG.2/2
Data Exp: Internal)
3. Press Menu button and go to pag.2/2 with PAG button
4. Press F2 Comm Parameter and check the baudrate value
NOTE: somewhere the baudrate value, because you will need later
http://en.wikipedia.org/wiki/RS-232http://en.wikipedia.org/wiki/RS-232http://wiki.stonex.pig.ro/index.php/File:SDM02.jpgSTONEX EUROPE srl Via Cimabue 39 20851 Lissone (MB) - Italy Phone +390392783008 Fax +390392789576 www.stonexpositioning.com
Download data from Total Station to PC.docx 2
On the computer
1. Run the Stonex Data Manager software
2. Go to Libretto --> Lettura/Scrittura porta seriale
3. Set Stonex R2 in Stazione Totale
4. Set the right COM port
5. Set the same baudrate set on the Total Station
6. Insert filename to assign to in Nome Libretto
7. Flag on Compone libretto a fine trasferimento
8. Click on Input libretto button to start the data transfer
NOTE: Check on the computer if appears Attivare operazione di trasferimento
On the Total Station
1. Press Menu button and go to pag. 2/4 with PAG button
2. Press F3 Data Transfer button
Nome Lavoro
Data: Meas.Val Meas.Val. = Export all known points and measured
points i
Porta RS233 Set the right COM port
More Job Not active function
Format .GSI . gsi = Export data format
3. Press F4 Send button
4. When the transfer finish, introduce the filename to assign to