Extended ServiceGuard/Oracle 9iRAC
a high availability cluster solution with
DWDM and Dark Fiber
Mai Cutler
HP Oracle Alliance Lab
Sandy Gruver
HP Oracle Advanced Technology Center
Stefan Pommerenk
Cluster and Parallel Storage Technology/Oracle
•Why “stretch” RAC cluster………….•what are the business drivers
•Review of 9iRAC architecture………•short review of RAC on HPUX
•What is DWDM and Dark Fiber?…...•Use Joe’s ideas and pictures
•Architecture used for the tests………•include mention of other partners - ATT and Nortel?
•Description of tests and results……..•Oracle tests……………………………………………………..•I/O tests…………………………………………………………•Failover tests……………………………………………………•?? Other testing - aka Bob Sauers suggestions (in support of customer-LCH)………………………………………………….
Agenda
Sandy
Sandy
Sandy
Mai
Mai
MaiMaiSandy
Sandy
•Why “stretch” RAC cluster
•Review of 9iRAC architecture
•What is DWDM and Dark Fiber?
•Architecture used for the tests
•Description of tests and results
Agenda
Why a “stretch” RAC cluster?what are the business drivers
A need for a single RAC solution which can span an extended distance (up to 100km)
This solution:• Is simpler than maintaining a standby
– Disaster site is “built-in” to the solution• Provides data protection in case of a local
disaster• Allows having a single RAC database spanning
two geographically distant sites• Ensures no data loss in case of a failure at one
site
Single Oracle Database
HP Server
Log filesDB System files
Rollback files
Temp files
Control files
Data files
Index files
Raw Device and File System Files
Archive Redo Logs
Review of 9iRAC architecture on HP-UXSingle Instance Oracle
HP Server
Redo Log filesInstance A
DB Systemfile(s)
Rollback/Undo files
Temp files
Control files
Data files
Index files
Redo Log filesInstance B
Raw Devices
System A System B
Archive Redo Logs Instance B
Oracle Real Application Cluster Database
Archive Redo Logs Instance A
Per instance
mirrored
Review of 9iRAC architecture on HP-UXOracle 9iRAC
Global Cache Service
USERUSER
SGA
Node 1, Instance A
USERUSERUSERUSER DBWRDBWR LGWRLGWR
DatabaseDatabaseBufferBufferCacheCache
Redo LogRedo LogBuffersBuffers
LCK0LCK0
DataDataDataData
USERUSER
SGA
Node 2, Instance B
USERUSERUSERUSER DBWRDBWR LGWRLGWR
DatabaseDatabaseBufferBufferCacheCache
Redo LogRedo LogBuffersBuffers
LCK0LCK0
RedoRedoRedoRedo RedoRedo
Control
9i Cache Fusion
Review of 9iRAC architecture on HP-UXCache services
Dense Wavelength Division Multiplexing
– Optoelectronic technology– Single optical fiber– Simultaneous transmission of signals– Wavelength of incoming signals changed – Similar to radio or TV broadcasting
What is DWDM and Dark FiberDWDM
What is DWDM
WavelengthConverter
WavelengthConverter
Ch 2
WavelengthConverter Ch 3
Ch 1
Ch 3Ch 2Ch 1
ESCON
100BaseFX
WavelengthConverter
WavelengthConverter
Ch 2
WavelengthConverter
Ch 3
Ch 1 ESCON
Fibre Channel
100BaseFX
Passive OpticalMultiplexer
Passive OpticalMultiplexer
Fibre Channel
1300 nm
1300 nm
1300 nm
1300 nm
1300 nm
1300 nm
Dark fiber
– fiber optic cable– sold by telecom provider– has no light or signal (is “dark”) until customer puts
a signal on it.
Commonly today, telecom providers sell dark fiber over DWDM
What is DWDM and Dark FiberDark Fiber
Common Carrier Dark Fiber
LOCAL CPUSITE A
REMOTE CPUSITE B
What is DWDM and Dark FiberClassic Dark Fiber
Common Carrier Dark Fiber
LOCAL CPUSITE A
REMOTE CPUSITE B
DWDM Device DWDM Device
What is DWDM and Dark FiberDark Fiber with DWDM
• Original tests
* Extended Distance Clusters (new name) allows distances up to 100 km using DWDM technology* Dense Wave Division Multiplexing (DWDM) technology provides the capability to extend the Fibre Channel link distance. * Network and disk communication sharing DWDM links.* Two and three site configurations.* VERITAS VxVM or CVM mirroring (supported up to 100 km)* Quorum Server, arbitrator nodes or dual cluster locks for arbitration.* Extended Distance ServiceGuard eRAC cluster configurations of 2 or 4 nodes using VERITAS CVM, for distances of up to 10 km
• Current tests* Extended Distance ServiceGuard eRAC cluster configurations of 2 nodes using VERITAS CVM, for distances of up to 100 km
Previous testing Extended ServiceGuard Cluster with DWDM
Architecture used for the tests Local ServiceGuard Cluster with 9iRAC
nova101 nova102
FibreChannel
VA7410
C L A SS
C L A SS
VA7410
H
Pr o C ur ve
Sw i t ch 4000 M
100 / 10B T 100 / 10B T 100 / 10B T 100 / 10B T100 / 10B T
H
Pr o C ur ve
Sw i t ch 4000 M
100 / 10B T 100 / 10B T 100 / 10B T 100 / 10B T100 / 10B T
HProCurveSwitch 4000M 100/10BT 100/10BT 100/10BT 100/10BT100/10BT
H
Pr o C ur ve
Sw i t ch 4000 M
100 / 10B T 100 / 10B T 100 / 10B T 100 / 10B T100 / 10B T
FibreChannel
GiGEthernet
Architecture used for the tests Extended ServiceGuard Cluster and 9i RAC with DWDM
100KmFibre
Nortel OPTeraNetwork
Nortel OPTeraNetwork
nova101 nova102
FibreChannel
VA7410100KmFibre
100KM
C L A SS
C L A SS
VA7410
H
Pr o C ur ve
Sw i t ch 4000 M
100 / 10B T 100 / 10B T 100 / 10B T 100 / 10B T100 / 10B T
H
Pr o C ur ve
Sw i t ch 4000 M
100 / 10B T 100 / 10B T 100 / 10B T 100 / 10B T100 / 10B T
HProCurveSwitch 4000M 100/10BT 100/10BT 100/10BT 100/10BT100/10BT
H
Pr o C ur ve
Sw i t ch 4000 M
100 / 10B T 100 / 10B T 100 / 10B T 100 / 10B T100 / 10B T
FibreChannel
GigEthernetGigEthernet
• 2 rp7410s (8 CPUs, 32GB RAM)• 2 Tachyon XL2 FibreChannel HBAs.• 4 ULTRA SCSI internal disks(73GB)• 4 Fibre-based GB Ethernet interfaces
• HP-UX B.11.11 and September 2002 bundle• ServiceGuard A.11.14.14• ServiceGuard Extension A.11.14• Veritas VxVM 3.5• Veritas CVM 3.5• Oracle 9.2.0.3 with RAC option, UDP/IPC
Description of tests Test Configuration
• CR-Test micro-level benchmark.• TPCC-like workload.• I/O performance tests• Failover Tests
Description of tests Test Scenarios
More information