SOL I CI T AT I ON NO. : F I LE NAM E: DW N BY: CKD BY: DESI GNED BY: DESCRI PT I ON 1 D 2 3 C 4 5 A B M ARK APPR. DATE: F I LE NUM BER: SI ZE: SUBM I TTED BY: PL OT SCALE: PL OT DATE: DATE M ARK DESCRI PT I ON CONT RACT NO. : IDENTIFICATION SHEET DATE APPR. ® of Engineers US Army Corps of Engineers US Army Corps U. S. ARM Y CORPS OF ENGI NEERS OM AHA, NEBRASKA OM AHA DI ST RI CT OMAHA DISTRICT MT J J DC J DC CI VI L ENGI NEERI NG CS505 04 / 06 / 2015 3 / 4 " = 1 ' ANSI D F E6 CHAI NL I NK F ENCE DET AI L S NO SCALE 16" MIN. DIA. 6 " 3 ' - 4 " M I N. 3 ' - 4 " M I N. 6 " 10'-0" MAXIMUM LINE POSTS TO BE EQUALLY SPACED 10" MIN. DIA. NO SCALE FASTENING DETAILS ROUND POST BRACE RAIL CLAMP DETAILS H-BEAM TENSION BAND DETAIL END OR GATE POST DETAIL 2.25" x 1.70" 2.375" O.D. 2.875" O.D. 2.25" x 1.70" 1.90" O.D. 2.25" x 1.70" 2.00" SQ. 2.375" O.D. 2.875" O.D. 2.50" SQ. 3.00" SQ. 4.00" O.D. 1.66" O.D. 1.50" O.D. 1.625" x 1.50" H-SECTION TUBULAR - SQUARE TUBULAR - ROUND TOP, BOTTOM & BRACE RAILS TUBULAR - ROUND LINE POSTS TUBULAR - SQUARE TUBULAR - ROUND CORNER, END & PULL POSTS USE AND SECTION FABRIC LESS THAN 72" MINIMUM OUTSIDE DIMENSIONS (NOMINAL) STEEL POST SCHEDULE FABRIC 72" TO 96" FABRIC OVER 96" NOTES: FINAL NUMBER IS FABRIC WIDTH IN INCHES TWBR - FENCE WITH TOP TENSION WIRE AND BOTTOM RAIL TWB - TENSION WIRE TOP AND BOTTOM TBR - FENCE WITH TOP AND BOTTOM RAILS TR - FENCE WITH TOP RAIL AND TENSION WIRE AT BOTTOM ON DOUBLE OUTRIGGER TYPE FE8 - CHAIN-LINK FENCE W/BARBED-WIRE AND BARBED-TAPE TYPE FE7 - CHAIN-LINK FENCE W/BARBED-WIRE ON DOUBLE OUTRIGGER TYPE FE6 - CHAIN-LINK FENCE W/BARBED-WIRE ON SINGLE OUTRIGGER TYPE FE5 - CHAIN-LINK FENCE WITHOUT BARBED-WIRE APRON FENCE LEGEND: EXAMPLES: FABRIC WIDTH. TOP AND BOTTOM TENSION WIRE, AND 48 INCH FE5-TWB-48 - CHAIN-LINK SECURITY FENCE WITH NO APRON, WIDTH. ON SINGLE OUTRIGGER, TOP RAIL, AND 72 INCH FABRIC FE6-TR-72 - CHAIN-LINK SECURITY FENCE WITH BARBED-WIRE H-BEAM ROUND POST LINE POST ATTACHMENTS TOP OR BRACE RAIL ATTACHMENT NO SCALE BRACE PANEL DETAIL 10'-0" MAX. 10'-0" MAX. NOTE: STRAIGHT RUNS EXCEED 500 FEET. PROVIDE BRACE PANEL WHENEVER 10'-0" MAXIMUM X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X NO SCALE EXTENSION ARM DETAILS LINE POST CORNER POST 1'-0" 1 ' - 0 " 45 DEGREES 1 ' - 6 " 6 " ( T YP . ) 1 ' - 0 " 1 ' - 10 " 7 . 5 " ( T Y P . ) 35 DEGREES X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X X H-SECTION FE6 CHAIN-LINK SECURITY FENCE DETAIL LINE POST BRACE RAIL (TYP.) TIE WIRES (3/8" MIN. DIA.) TRUSS ROD CONCRETE BASE OR PULL POST CORNER, END, LINE POST OF FABRIC BOTTOM (9 GAGE, 2" MESH) CHAIN-LINK FABRIC BAND TENSION (3/8" MIN. DIA.) TRUSS ROD WIRE TENSION CARRIAGE BOLT TENSION BAR EACH FABRIC LINK TENSION BAR TO ENGAGE FABRIC TOP AND BOTTOM OF FABRIC) (15" O.C. MAX. AND WITHIN 4" FROM TENSION BAND FABRIC (2'-0" O.C. MAX.) 9-GAGE TIE WIRES OF FABRIC) TOP AND BOTTOM WITHIN 4" FROM (15" O.C. MAX AND TIE WIRE OF FABRIC) TOP AND BOTTOM WITHIN 4" FROM (15" O.C. MAX AND TIE WIRE TRUSS ROD TRUSS ROD LINE POST LINE POST BRACE RAILS RAILS BRACE PULL POST (TYP.) TIE WIRES ON EXTENSION ARMS BARBED-WIRE APRON RIVETED FLUSH (TYP.) " PLAIN PIN 8 3 RIVETED FLUSH (TYP.) 3/8" PLAIN PIN LOCK PIN (TYP.) WIRE (TYP.) BARBED F 211 - 10 - 08 F CW 9 CS505 . dgn W 9128 F - 15 - R- 0047 4 T H I D CAB, UAS HANGAR F ORT CARSON, COL ORADO PN81357 ( F Y15 ) AND RAIL REQUIREMENTS PER LEGEND BELOW. 4. SEE PLAN SHEETS FOR HEIGHT OF CHAIN LINK FABRIC, WIRE PROTECTED. SHALL HAVE APRON EXTENDED OUTWARD FROM THE AREA BEING 3. UNLESS OTHERWISE SHOWN OR SPECIFIED, ALL FE6 FENCE SECURE AREA. FABRIC SHALL BE PLACED ON THE OPPOSITE SIDE OF THE ON THE SECURE SIDE OF THE FENCE ALIGNMENT. CHAIN-LINK 2. WIRE TIES, RAILS, POSTS, AND BRACES SHALL BE CONSTRUCTED SPECIFICATIONS. MANUFACTURER, AS LONG AS THEY COMPLY WITH THE NOT INTENDED TO LIMIT METHOD OF INSTALLATION TO ONE 1. DETAILS SHOWN ARE TO CLARIFY REQUIREMENTS AND ARE AS SPECIFIED TENSION WIRE TENSION WIRE TRUSS ROD AND BAND BASE CONCRETE GRADE LINE GRADE TRUSS ROD DIAMETER GRADE 1/2 UP ROD INSTALL TO PLACE BOTTOM RAIL ELEVATION DIAMETER BOTTOM RAIL GRADE AT 1/2 (2'-0" O.C. MAX.) 9-GAGE TIE WIRES BOTTOM RAIL ATTACHMENT GRADE THE BOTTOM FABRIC BARBED ON 3 AM END #0003 , GENERAL REVI SI ONS 3 3 3 3 FENCING ATTACHED TO CHAIN LINK TOP OF PRAIRIE DOG FENCE 24 " 24 " 36" PRAIRIE DOG FENCING 3 STRENGTH. WOVEN IN HORIZONTALLY FOR 20 GAUGE, WITH EXTRA LINE WIRES 1" HEXAGONAL GALV STEEL, FABRIC CHICKEN WIRE, 60" WIDE, ON THE GROUND. FENCE LINK FENCE AND INSTALLED ATTACHED TO CHAIN PRAIRIE DOG FENCING GROUNDING DETAIL NO SCALE 10 ' - 0 " 1 ' - 0 " STEEL GROUND ROD 3/4" DIA. COPPER-CLAD OF COPPER CLAMP-TYPE FITTING WELD OR APPROVED MOLDED EXOTHERMIC COPPER WIRE #8 AWG SOLID FENCE POST 3 BENEATH AGGREGATE BORDER. STAPLES AT 18" O.C. CENTER AND EDGE CENTER. ATTACH FENCE TO GROUND WITH GALV WIRE AT 12" ON CENTER TOP,BOTTOM AND FENCE WITH 17 GAUGE ALUM OR GALV STEEL ATTACH PRAIRIE DOG FENCE TO CHAIN LINK F ABRI C W I DT H 96 " 70 " CHAIN LINK FABRIC RAIL BOTTOM POST 05 / 08 / 2015 OF FENCE) MID RAIL (ENTIRE LENGTH (ENTIRE LENGTH OF FENCE) 1/2 IT'S DIAM IN SOIL BOTTOM RAIL BURIED INSTALLED ON CHICKEN WIRE FABRIC. LEVEL WITH GROUND SURFACE AND AGGRREGATE.TOP OF AGGREGATE 3" DEEP X 36" WIDE , 3/4" CLEAN

EXTENSION ARM DETAILS€¦ · type fe6 - chain-link fence w/barbed-wire on single outrigger type fe5 - chain-link fence without barbed-wire apron fence legend: examples: fabric width

  • Upload
    others

  • View
    17

  • Download
    0

Embed Size (px)

Citation preview

Page 1: EXTENSION ARM DETAILS€¦ · type fe6 - chain-link fence w/barbed-wire on single outrigger type fe5 - chain-link fence without barbed-wire apron fence legend: examples: fabric width

SO

LICIT

ATIO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR.

DA

TE:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BMIT

TE

D B

Y:

PL

OT S

CA

LE:

PL

OT D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT N

O.:

IDENTIFICATION

SHEET

DA

TE

AP

PR.

®of Engineers

US Army Corps

of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

OM

AH

A,

NE

BR

AS

KA

OM

AH

A DIS

TRIC

T

OMAHA DISTRICT

MTJ

JD

C

JD

C

CIVIL E

NGIN

EE

RIN

G

CS505

04/0

6/2

015

3/4" = 1'

AN

SI

D

FE6 C

HAIN

LIN

K F

EN

CE D

ET

AIL

S

NO SCALE

16" MIN. DIA.

6"

3'-4"

MIN.

3'-4"

MIN.

6"

10'-0" MAXIMUM

LINE POSTS TO BE EQUALLY SPACED

10" MIN. DIA.

NO SCALE

FASTENING DETAILS

ROUND POST

BRACE RAIL CLAMP DETAILS

H-BEAM

TENSION BAND DETAIL

END OR GATE POST DETAIL

2.25" x 1.70"

2.375" O.D. 2.875" O.D.

2.25" x 1.70"

1.90" O.D.

2.25" x 1.70"

2.00" SQ.

2.375" O.D. 2.875" O.D.

2.50" SQ. 3.00" SQ.

4.00" O.D.

1.66" O.D.

1.50" O.D.

1.625" x 1.50"H-SECTION

TUBULAR - SQUARE

TUBULAR - ROUND

TOP, BOTTOM & BRACE RAILS

TUBULAR - ROUND

LINE POSTS

TUBULAR - SQUARE

TUBULAR - ROUND

CORNER, END & PULL POSTS

USE AND SECTIONFABRIC LESS THAN 72"

MINIMUM OUTSIDE DIMENSIONS (NOMINAL)

STEEL POST SCHEDULE

FABRIC 72" TO 96" FABRIC OVER 96"

NOTES:

FINAL NUMBER IS FABRIC WIDTH IN INCHES

TWBR - FENCE WITH TOP TENSION WIRE AND BOTTOM RAIL

TWB - TENSION WIRE TOP AND BOTTOM

TBR - FENCE WITH TOP AND BOTTOM RAILS

TR - FENCE WITH TOP RAIL AND TENSION WIRE AT BOTTOM

ON DOUBLE OUTRIGGER

TYPE FE8 - CHAIN-LINK FENCE W/BARBED-WIRE AND BARBED-TAPE

TYPE FE7 - CHAIN-LINK FENCE W/BARBED-WIRE ON DOUBLE OUTRIGGER

TYPE FE6 - CHAIN-LINK FENCE W/BARBED-WIRE ON SINGLE OUTRIGGER

TYPE FE5 - CHAIN-LINK FENCE WITHOUT BARBED-WIRE APRON

FENCE LEGEND:

EXAMPLES:

FABRIC WIDTH.

TOP AND BOTTOM TENSION WIRE, AND 48 INCH

FE5-TWB-48 - CHAIN-LINK SECURITY FENCE WITH NO APRON,

WIDTH.

ON SINGLE OUTRIGGER, TOP RAIL, AND 72 INCH FABRIC

FE6-TR-72 - CHAIN-LINK SECURITY FENCE WITH BARBED-WIRE

H-BEAM ROUND POST

LINE POST ATTACHMENTS

TOP OR BRACE RAIL ATTACHMENT

NO SCALE

BRACE PANEL DETAIL

10'-0" MAX. 10'-0" MAX.

NOTE:

STRAIGHT RUNS EXCEED 500 FEET.

PROVIDE BRACE PANEL WHENEVER

10'-0" MAXIMUM

X X X X X X

XX

X XXXXXXXXXXX

X

X X X X X X

X X X X XXXXX

X X X X X X X

XXXXXX

X X X X X X

X X X X

XXXX

X X X X X X X

XXX

X X X

X X X X X

XXXXX

X X X X X

X

X

X

X

X

X X

X X

X X

X

XXX

X

X

X

NO SCALE

EXTENSION ARM DETAILS

LINE POST CORNER POST

1'-0"

1'-0"

45 DEGREES

1'-6" 6"

(TYP.)

1'-0"

1'-10" 7.

5" (T

YP.)

35 DEGREES

X X X X X

XXXXX

X X X X X

X X X X

X

XX

XXX

X X

X X X X

XXXX

X X X X

X X X X

XXXX

X X X X

X

X

X X

X

X

H-SECTIONFE6 CHAIN-LINK SECURITY FENCE DETAIL

LINE POST

BRACE RAIL

(TYP.)

TIE WIRES

(3/8" MIN. DIA.)

TRUSS ROD

CONCRETE BASE

OR PULL POST

CORNER, END,

LINE POST

OF FABRIC

BOTTOM

(9 GAGE, 2" MESH)

CHAIN-LINK FABRIC

BAND

TENSION

(3/8" MIN. DIA.)

TRUSS ROD

WIRE

TENSION

CARRIAGE BOLT

TENSION BAR

EACH FABRIC LINK

TENSION BAR TO ENGAGE

FABRIC

TOP AND BOTTOM OF FABRIC)

(15" O.C. MAX. AND WITHIN 4" FROM

TENSION BAND

FABRIC

(2'-0" O.C. MAX.)

9-GAGE TIE WIRES

OF FABRIC)

TOP AND BOTTOM

WITHIN 4" FROM

(15" O.C. MAX AND

TIE WIRE

OF FABRIC)

TOP AND BOTTOM

WITHIN 4" FROM

(15" O.C. MAX AND

TIE WIRE

TRUSS ROD TRUSS ROD

LINE POSTLINE POST BRACE RAILS

RAILS

BRACE

PULL POST

(TYP.)

TIE WIRES

ON EXTENSION ARMS

BARBED-WIRE APRON

RIVETED FLUSH (TYP.)

" PLAIN PIN83

RIVETED FLUSH (TYP.)

3/8" PLAIN PIN

LOCK PIN (TYP.)

WIRE (TYP.)

BARBED

F211-1

0-0

8

FC

W9

CS505.d

gn

W9128F-1

5-R-0

047

4T

H I

D C

AB, U

AS H

AN

GA

R

FO

RT C

AR

SO

N,

CO

LO

RA

DO

PN

81357 (F

Y15)

AND RAIL REQUIREMENTS PER LEGEND BELOW.

4. SEE PLAN SHEETS FOR HEIGHT OF CHAIN LINK FABRIC, WIRE

PROTECTED.

SHALL HAVE APRON EXTENDED OUTWARD FROM THE AREA BEING

3. UNLESS OTHERWISE SHOWN OR SPECIFIED, ALL FE6 FENCE

SECURE AREA.

FABRIC SHALL BE PLACED ON THE OPPOSITE SIDE OF THE

ON THE SECURE SIDE OF THE FENCE ALIGNMENT. CHAIN-LINK

2. WIRE TIES, RAILS, POSTS, AND BRACES SHALL BE CONSTRUCTED

SPECIFICATIONS.

MANUFACTURER, AS LONG AS THEY COMPLY WITH THE

NOT INTENDED TO LIMIT METHOD OF INSTALLATION TO ONE

1. DETAILS SHOWN ARE TO CLARIFY REQUIREMENTS AND ARE

AS SPECIFIED

TENSION WIRE

TENSION WIRE

TRUSS ROD AND BAND

BASE

CONCRETE

GRADE LINE

GRADE

TRUSS ROD

DIAMETER

GRADE 1/2 UP ROD

INSTALL TO PLACE

BOTTOM RAIL

ELEVATION

DIAMETER

BOTTOM RAIL

GRADE AT 1/2

(2'-0" O.C. MAX.)

9-GAGE TIE WIRES

BOTTOM RAIL ATTACHMENT

GRADE

THE BOTTOM

FABRIC BARBED ON

3A

ME

ND #

0003,

GE

NE

RA

L R

EVISIO

NS

3

3

3

3

FENCINGATTACHED TO CHAIN LINKTOP OF PRAIRIE DOG FENCE

24"

24"

36"

PRAIRIE DOG FENCING 3

STRENGTH.

WOVEN IN HORIZONTALLY FOR

20 GAUGE, WITH EXTRA LINE WIRES

1" HEXAGONAL GALV STEEL,

FABRIC CHICKEN WIRE, 60" WIDE,

ON THE GROUND. FENCE

LINK FENCE AND INSTALLED

ATTACHED TO CHAIN

PRAIRIE DOG FENCING

GROUNDING DETAILNO SCALE

10'-0"

1'-0"

STEEL GROUND ROD

3/4" DIA. COPPER-CLAD

OF COPPER

CLAMP-TYPE FITTING

WELD OR APPROVED

MOLDED EXOTHERMIC

COPPER WIRE

#8 AWG SOLID

FENCE POST

3

BENEATH AGGREGATE BORDER.

STAPLES AT 18" O.C. CENTER AND EDGE

CENTER. ATTACH FENCE TO GROUND WITH GALV

WIRE AT 12" ON CENTER TOP,BOTTOM AND

FENCE WITH 17 GAUGE ALUM OR GALV STEEL

ATTACH PRAIRIE DOG FENCE TO CHAIN LINK

FA

BRIC W

IDT

H 9

6"

70"

CHAIN LINK FABRIC

RAIL

BOTTOM

POST

05/0

8/2

015

OF FENCE)

MID RAIL (ENTIRE LENGTH

(ENTIRE LENGTH OF FENCE)

1/2 IT'S DIAM IN SOIL

BOTTOM RAIL BURIED

INSTALLED ON CHICKEN WIRE FABRIC.

LEVEL WITH GROUND SURFACE AND

AGGRREGATE.TOP OF AGGREGATE

3" DEEP X 36" WIDE , 3/4" CLEAN

Page 2: EXTENSION ARM DETAILS€¦ · type fe6 - chain-link fence w/barbed-wire on single outrigger type fe5 - chain-link fence without barbed-wire apron fence legend: examples: fabric width

SO

LICIT

ATIO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR.

DA

TE:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BMIT

TE

D B

Y:

PL

OT S

CA

LE:

PL

OT D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT N

O.:

IDENTIFICATION

SHEET

DA

TE

AP

PR.

®of Engineers

US Army Corps

of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

OM

AH

A,

NE

BR

AS

KA

OM

AH

A DIS

TRIC

T

OMAHA DISTRICT

MTJ

JD

C

JD

C

CIVIL E

NGIN

EE

RIN

G

CS506

04/0

6/2

015

3/4" = 1'

AN

SI

D

2"

MIN.

5"

MA

X.

6" DIA.

6"

2'-0"

10"

1"

36"

43"

48"

12"

6"

6" DIA. P.C. CONC.

OFFSET HINGE STANDARD HINGE

LATCH ASSEMBLY

DROP ROD ASSEMBLY

GATE POST SCHEDULE

6' OR LESS

MORE THAN 13' TO 18'

MORE THAN 6' TO 13'

MORE THAN 18'

(NOMINAL)

GATE LEAF WIDTH

(NOMINAL)

OUTSIDE DIMENSION

2.875" O.D.

2.5" SQ.

4.0" O.D.

6.625" O.D.

8.625" O.D.

NOTES:

NO SCALE

SWING GATE DETAILS

GATE KEEPER

(TO HOLD GATE OPEN)

PLAN

A

SECTION A

DROP ROD FOUNDATION

SECTION

GATE POST DETAIL

AT CURB AND GUTTER

FE

NC

E F

AB

RIC

GATE LEAF

2"

MIN.

5"

MA

X.

NO SCALE

DOUBLE SWING GATE (TYPE FE6 FENCE)

ELEVATION

2'-10" FOR POSTS 4" O.D. & LESS

" O.D.853'-4" FOR POSTS 6

" O.D.853'-10" FOR POSTS 8

6"

4" O.D. & LESS

16" DIA. MIN. FOR GATE POSTS

OVER 4" O.D.

24" DIA. MIN. FOR GATE POSTS

1'-0"

X X

XX

X X X X X X X X X

XXXXXXX

X X X X X X X X X X X X X X

XXXXXXX

X X X X X X X

X X X X X X X

XXXXXXX

X X X X X X X

X X X X X X X

XXXXXXX

X X X X X X X

X X X X

XXXX

X X X X

X X X X X X X X X X X X X X X X X X X X X X X X X X X X X XXX

X

XX

X

XX

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X

XX

X

X X

X

XX

X

XX

X X

X X X X X

XXXXX

X X X X X

PLAN

DIRECTION OF GATE SWING (TYP.)

GATE OPENING

GATE FRAME

CHAIN-LINK FABRIC OF BARBED-WIRE

3 VERTICAL STRANDS BARBED-WIRE

3 STRANDS OF

BARBED WIRE

3-STRANDS OF

BARBED WIRE

3-STRANDS OF

LINE POST

ASSEMBLY

LATCH

GATE FRAME

DROP ROD

" TRUSS RODS83

FABRIC

CHAIN-LINK

HINGE

RAIL (TYP.)

BRACE LINE POST

(TYP.)

TRUSS ROD

(TYP.)

BRACE RAIL

LINE

GRADE

AND GUTTER

EXIST. CURBFULL DEPTH

SAWCUT CURB

GATE

3" MIN.

GUTTER

SAWCUT

SAND/GRAVEL

1" I.D. STEEL PIPE

PAVEMENT

BITUMINOUS

SURFACE

PAVED

PAVEMENT

P.C. CONC.

" DIA. DROP ROD21

AND GUTTER

NEW CURB

JOINT

" EXP.21

NEW GATE

WASHER

POST FOUND.

NEW GATE

EXIST. CURB

HINGE

STANDARD

POST

GATE

" EXP. JOINT21

F211-1

0-0

8

FC

W9

CS506.d

gn

W9128F-1

5-R-0

047

FE

NC

E F

AB

RIC

GATE OPENING

4'-0"

NO SCALE

PERSONNEL GATE

TYPE FE6 FENCE

X X

XX

X X X X X X X

XXXXX

X X X X X

1'-0"

BARBED WIRE

3 STRANDS OF

BARBED-WIRE

3-STRANDS OF

HINGE

POST

GATE

HINGE

BRACE RAIL (TYP.)

GRADE LINE

TRUSS ROD (TYP.)

W/ LATCH PROTECTOR

PUSH-BUTTON LOCKSET

FE5-48-SO-HD-6

EXAMPLES: FE6-84-DO-RA-24

OPENING - FEET (CLEAR OPENING BETWEEN GATE POSTS)

- HO (OFFSET)

HINGE - RA (STANDARD)

- DO (DOUBLE)

TYPE OPENING - SO (SINGLE)

FENCE HEIGHT - INCHES

FENCE TYPE - FE5, FE6, ETC.

5. GATES SHALL BE DESIGNATED AS FOLLOWS:

SEE SPECIFICATION 08 71 00 DOOR HARDWARE.

LOCKSETS WITH LATCH PROTECTORS. FOR ADDITIONAL INFORMATION

4. ALL PERSONNEL GATES SHALL BE EQUIPPED WITH PUSH-BUTTON

CONSTRUCTION OF ALL GATES SUPPLIED.

THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE PROPER RIGID

USED IN LIEU OF TRUSS RODS TO BRACE ALL WELDED GATE FRAMES.

AT CONTRACTOR'S OPTION, A WELDED HORIZONTAL BRACE MAY BE

CONSTRUCTION OR SHALL BE ASSEMBLED USING HEAVY FITTINGS.

OR 2.00" NOMINAL (SQUARE). GATE FRAMES SHALL BE WELDED

3. ALL GATE FRAMES SHALL BE A MINIMUM OF 1.90" NOMINAL (ROUND)

LATCH ASSEMBLY AND GATE KEEPERS EXCEPT AS NOTED.

2. SWING GATES SHALL BE CONSTRUCTED WITH DROP RODS, PADLOCKS,

AS LONG AS THEY COMPLY WITH THE SPECIFICATIONS.

INTENDED TO LIMIT METHOD OF INSTALLATION TO ONE MANUFACTURER,

1. DETAILS SHOWN ARE TO CLARIFY REQUIREMENTS AND ARE NOT

FE6 C

HAIN

LIN

K S

WIN

G G

AT

E D

ET

AIL

S

4T

H I

D C

AB, U

AS H

AN

GA

R

PN

81357 (F

Y15)

FO

RT C

AR

SO

N,

CO

LO

RA

DO

PIPE GUARD TYP.

BOTTOM RAIL

TENSION WIRE

BOTTOM RAIL

TOP TENSION WIRE

3A

ME

ND #

0003,

GE

NE

RA

L R

EVISIO

NS

3

3

MID RAIL

05/0

8/2

015

Page 3: EXTENSION ARM DETAILS€¦ · type fe6 - chain-link fence w/barbed-wire on single outrigger type fe5 - chain-link fence without barbed-wire apron fence legend: examples: fabric width

SO

LICIT

ATIO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR.

DA

TE:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BMIT

TE

D B

Y:

PL

OT S

CA

LE:

PL

OT D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT N

O.:

IDENTIFICATION

SHEET

DA

TE

AP

PR.

®of Engineers

US Army Corps

of Engineers

US Army Corps

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

OM

AH

A,

NE

BR

AS

KA

OM

AH

A DIS

TRIC

T

OMAHA DISTRICT

MTJ

JD

C

JD

C

CS507

04/0

6/2

015

3/4" = 1'

AN

SI

D

F211-1

0-0

8

FC

W9

CS507.d

gn

W9128F-1

5-R-0

047

4T

H I

D C

AB, U

AS H

AN

GA

R

PN

81357 (F

Y15)

FO

RT C

AR

SO

N,

CO

LO

RA

DO

FE6 C

HAIN

LIN

K C

AN

TIL

EV

ER G

AT

E D

ET

AIL

S

NO SCALE

PLAN

NO SCALE

ELEVATION

1 1

GATE POST SPACING

10'-0" MAXIMUM

DIA.

16" MIN.

3'-6"

MIN.

6"

6"

3'-6"

5" MAX. CLEAR

GATE OPENING

FE

NC

E H

EIG

HT

BACK FRAME GATE FRAME

GATE OPENING

SECURE SIDE

UNSECURE SIDE

1SECTION NO SCALE

LOWER GUIDE ROLLER ASSEMBLY

NO SCALE

UPPER TRUCK ROLLER ASSEMBLY

X X

XX

X X

X X X X X X X

XXXXXXX

X X X X X X X

X X X X X X X

XXXXXXX

X X X X X X X

X X X X

XXXX

X X X X

X X

XX

X X X X X X X X X

XXXXXXX

X X X X X X X X X X X X

XXXXX

X X X X X

X X

XX

X X X X X X X X

XXXXXX

X X X X X X X X X X

XXXX

X X X X

X X

XX

X X X X X

XXX

X X X

X X

XX

X X

XXX

XX

X

XX

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X

X X

X

XX

X

X X

X

XX

X

XX

X X

X X X X X

XXXXX

X X X X X

XX

X X

XX

XX

X X

XX

X X

XX

X X X X X

XXX

X X XX

X

X X X X

XXX

X X X

X X X X XX X X XX

X X X X X X X X X X X X X

XX

XX

XX

XX

XX

X

XX

XX

XX

XX

XX

XX

XX

X

NOTES:

WARNING

Moving Gate Can Cause

KEEP CLEAR! Gate may move at any time

Without Prior Warning

Do not let children operate the gate or play

In the gate area.

This entrance is for vehicles only.

Pedestrians must use separate entrance.

!

NO SCALE

WARNING SIGN DETAIL

WARNING

Moving Gate Can Cause

Serious Injuy or DeathKEEP CLEAR! Gate may move at any time

Without Prior Warning

Do not let children operate the gate or play

In the gate area.

This entrance is for vehicles only.

Pedestrians must use separate entrance.

!

Serious Injury or Death

GATE

PIPE GUARD

CONCRETE BASE

LINE POST

(TYP.)

TIE WIRES

(3/8" MIN. DIA.)

TRUSS ROD

BRACE RAIL

POST (1 OF 3)

4" DIA. GATE

#52 ROLL CHAIN

4" DIA. POST

OPERATOR

GATE

4" DIA. POST UPPER CORNERS

WELDED AT

TRUSS RODS

BAR & BANDS

STRETCHER

TRUSS ROD

3/8" DIA.

4" O.D. POST

4" O.D. POST

GATE FRAME

ASSEMBLY

GUIDE ROLLER

GATE FRAME

ASSEMBLY

TRUCK ROLLER

GATE

IRON ROLLERS

MALLEABLE

IRON ROLLERS

MALLEABLE

4" O.D. POST 4" O.D. POST

GATE

ROLLER ASSEMBLY

LOWER GUIDE

ROLLER ASSEMBLY

UPPER TRUCK

BARBED WIRE

3 STRANDS OF

WIRE

STRANDS OF BARBED

OUTIGGER WITH 3

BARBED-WIRE

3-STRANDS OF

BARBED WIRE

3 STRANDS OF

BARBED-WIRE

3-STRANDS OF

GATE OPERATOR

SIGN

WARNING

CATCH

LOCKING

MECHANICAL

ELECTRO-

6. NOT ALL GATES HAVE AUTOMATIC OPENERS. SEE PLAN SHEET FOR DETAILS.

FABRIC.

5. WARNING SIGNS SHOWN SHALL BE INSTALLED ON EACH SIDE OF FENCE

TO LIMIT OTHER TYPES OF GATE SECTIONS AND METHODS OF INSTALLATION.

4. DETAILS SHOWN ARE TO CLARIFY REQUIREMENTS AND ARE NOT INTENDED

3. ROLLERS SHALL BE EITHER INTERNAL OR EXTERNAL.

2. GATE FRAMES SHALL BE EITHER ZINC-COATED STEEL OR ALUMINUM ALLOY.

1. CANTILEVERED SLIDE GATES SHALL CONFORM TO ASTM F1184.

PIPE GUARD TYP

CIVIL E

NGIN

EE

RIN

G

TOP TENSION WIRE

BOTTOM RAIL

3A

ME

ND #

0003,

GE

NE

RA

L R

EVISIO

NS

3

MID RAIL

05/0

8/2

015

Page 4: EXTENSION ARM DETAILS€¦ · type fe6 - chain-link fence w/barbed-wire on single outrigger type fe5 - chain-link fence without barbed-wire apron fence legend: examples: fabric width

SO

LICIT

ATIO

N N

O.:

FIL

E N

AM

E:

DW

N B

Y:

CK

D B

Y:

DE

SIG

NE

D B

Y:

DE

SC

RIP

TIO

N

1

D

2 3

C

4 5

A

B

MA

RK

AP

PR.

DA

TE:

FIL

E N

UM

BE

R:

SIZ

E:

SU

BMIT

TE

D B

Y:

PL

OT S

CA

LE:

PL

OT D

AT

E:

DA

TE

MA

RK

DE

SC

RIP

TIO

N

CO

NT

RA

CT N

O.:

IDENTIFICATION

SHEET

DA

TE

AP

PR.

®of Engineers

US Army Corps

of Engineers

US Army Corps

TALS-TS SYSTEM EQUIPMENT LAYOUT PLAN GCS AND TALS PADS

CONC. CURB

COMPACTED SUBGRADE

WRITTEN INSTRUCTIONS

(INSTALL PER MANUFACTURER'S

OPTION, BY THE KNOX CO.

EQUAL; SURFACE MOUNT

MODEL # 3265 KNOX BOX OR BOTH SIDES

CONTINUOUS HOLD DOWN CLEATS,

METAL CAP FLASHING W/

TO END OF RUNWAY

#4 @ 12" E.W.

NOTES:

NO SCALE

NO SCALE

FREE STANDING KNOX BOX

HELIOS BOLD II, HELVETICA BLACK ROMAN, OR HELVETICA BOLD ROMAN.7. LETTERING STYLE SHALL BE EITHER HELIOS EXTRA BOLD CONDENSED, BY THE CONTRACTOR6. DECALOMANIA FOR CORPS OF ENGINEERS INSIGNIA WILL BE FURNISHED BACKGROUND. BE 3" HIGH. ALL LETTERING SHALL BE WHITE ENAMEL ON GREY5. PROJECT NAME LETTERS SHALL BE 6" HIGH. ALL OTHER LETTERS SHALL COLOR SHALL MATCH BENJAMIN MOORE 1559 ARTIC SHADOWS. CONFORMING TO MASTER PAINTERS INSTITUTE MPI-9, MPI GLOSS LEVEL 6.4. PAINT WITH ONE EXTERIOR OIL PRIME COAT AND EXTERIOR TYPE ALKYD, AND SANDED.3. BEFORE PAINTING, SURFACE SHALL BE CLEAN, DRY, FREE OF GREASE2. PLYWOOD SHALL BE EXTERIOR TYPE, A-C GRADE.1. POSTS SHALL BE S4S.

SPECIFICATIONS

MANUFACTURER'S

SCREW MOUNT PER

FOR POS. DRAINAGE

CONC FOOTER - SLOPE

FNS. GRADE

SET PLUMB

TO MATCH SECURITY FENCE;

3/16; HOT DIPPED GALVANIZED

HIGH STRENGTH STEEL 5 X 3 X

U.S. ARMY INSTALLATION PROJECT SIGN DETAILS

NOTES:

THEIR LIST OF APPROVED PRODUCTS.

DIVISION REQUIREMENTS AND BE SELECTED FROM

FORT CARSON FIRE DEPT, FIRE PREVENTION

PRODUCT SELECTED SHALL CONFORM TO THE

BOX BY THE KNOX CORPORATION. ACTUAL

1. BASIS OF DESIGN PRODUCT: MODEL 3265 KNOX

3Kw GEN, APPROX 3' X 3'

CL

30.0

0'

TALS-TS ANTENNA, 2' DIAMETERRLM UNIT, 2' X 3'

UPS ASSEMBLY, 2' X 2'

4' X 4'

METS TRIPOD PAD

FOR TALS-TS EQUIPMENT PLACEMENT

10' X 10'-6" CONCRETE PAD

FINISHED GRADE

CHAMFER EDGE

BASE COURSE

8" RIGID PAVEMENT

6" PREPARED SUBGRADE (95%)TYP.

#5 CONT,

U.S.

AR

MY C

OR

PS O

F E

NGIN

EE

RS

OM

AH

A,

NE

BR

AS

KA

OM

AH

A DIS

TRIC

T

OMAHA DISTRICT

FC

W9

CS510.d

gn

4T

H I

D C

AB, U

AS H

AN

GA

R

CS510

MIS

CE

LL

AN

EO

US D

ET

AIL

SF211-1

0-0

8

04/0

6/2

015

W9128F-1

5-R-0

047

PN

81357 (F

Y15)

FO

RT C

AR

SO

N,

CO

LO

RA

DO

CompanyConstruction

Installation

Service Command

NameProject

Omaha District

US Army Corps

of Engineers

3'-0"

3'-0"

4'-0"

8'-0"

3'-3"

2"

8"

5"

25"10"

8"

8"

4"

4'-0"

FRONT VIEW END VIEW

(SEE NOTE 6)

DECALCOMANIA

EACH POST

AT 6" CTRS.

GALV. NAILS

NAIL WITH 8D

GROUND LINE

4" X 4" POST

EXTERIOR PLYWOOD

4' X 8' X 1/2"

GALV. BOLT

1/2" DIAM.

GALV. BOLT

1/2" DIAM.

ANCHOR

2" X 6"

2" X 4" BRACE

C

CL

L

UAS SITE EQUIPMENT SCHEDULE

SITE EQUIPMENT LOCATION

NO SCALE

PAD TYPE AND SIZE

GCS

GDT

SGDT

NOTES

NEAR UAS HANGAR

OPPOSITE SIDE OF RUNWAYPAD SLOPE 5% MAXCRUSHED ROCK, 35'DIAM.

PAD SLOPE 8.75% MAXCRUSHED ROCK, 30'DIAM.

AND OUTSIDE OF RUNWAY LATERAL CLEAR ZONE FOR AIRFIELD AIRCRAFT.MUST HAVE CLEAR VIEW TO TALS. LOCATED PER RUNWAY OP SITE SURVEYADJACENT TO UAS HANGAR. TO ACCOMODATE 8' X 16' GCS STATION MODULE,

TRANSITIONAL SURFACE.LATERAL CLEAR ZONE FOR AIRFIELD AIRCRAFT AND ANTENNA NOT TO PENETRATE CLEAR ZONE AROUND SGDT OF 78' RADIUS. LOCATED OUTSIDE OF RUNWAYSGDT LOCATED PER PM-UAS SITE SURVEY WITH OPEN SOUTH HORIZON VIEW.

TALS-TS

BE 2' PLUS OR MINUS RUNWAY ELEV NORMAL TO SYSTEM. ALIGNMENT POINT (100' PAST TOUCHDOWN POINT). ELEVATION OF PAD SHALLCLEAR LOS WITH AIRCRAFT ON RUNWAY, THRESHOLD, TOUCHDOWN AND TALS-TS SYSTEM LOCATED PER UAS RUNWAY OPERATIONAL SITE SURVEY.

AND RIGHT RUNWAY CENTERLINEEND OF RUNWAY, AND 250' LEFTLOCATED 1,000' FROM EITHERTWO SETS OF SYSTEMS

ISU 90 UAS HANGAR. IMMEDIATELY ADJACENT TO THE

DIRECT ACCESS FROM HARDSTAND

12" TYP

OF ADJACENT PAVEMENT

SEE SITE PLAN FOR LOCATION

NOTE:

MTJ

MTJ

MTJ

PAD 1/2" ABOVE GRADE6" THICK, PAD SLOPE 1.75% MAXCONCRETE, 14' X 18'

PAD SURFACE 1/2" ABOVE GRADEPAD SLOPE 1.75% MAX. ONE CONCRETE PAD 4' X 4' ONE CONCRETE PAD 10' X 10.5' &

PAD SURFACE 3" ABOVE GRADESLOPE MAX 1.75%108"L x 88"W x 91.35"H. OF ISU-90 STORAGE UNITS CONC PAD TO ALLOW STORAGE

AM

EN

D #

0003,

GE

NE

RA

L R

EVISIO

NS

05/0

8/2

015

3

NO SCALE

3

3

2'-0"

8"

1'-0"

VARIES, SEE SITE PLAN

1/2"

OPPOSITE SIDE OF RUNWAY

RUNWAY OPERATIONAL SITE SURVEY.ZONE, WITHIN 5'-8' OF RUNWAY CENTERLINE ELEV NORMAL TO PAD. LOCATED PERLOCATED 125' APART, 50' TOWERS NOT TO PENETRATE RUNWAY TRANSITION GDT LOCATED OUTSIDE OF THE LATERAL CLEAR ZONE FOR AIRFIELD AIRCRAFT

Page 5: EXTENSION ARM DETAILS€¦ · type fe6 - chain-link fence w/barbed-wire on single outrigger type fe5 - chain-link fence without barbed-wire apron fence legend: examples: fabric width

SHEETIDENTIFICATION

1 2 3 4 5

DR

AWN

BY:

DES

I GN

BY:

SBM

T BY

:

SIZ

E :FI

LE N

AM

E:

ISSU

E D

ATE

:

CO

NTR

ACT

NO

.:

SO

LIC

ITAT

ION

NO

.:

US

ARM

Y C

OR

PS O

F EN

GIN

EER

S

CKD

BY:

US Army Corps ofEngineers ®

22" x

34"

D

C

B

A

FILE

NU

MBE

R:

PLO

T SC

ALE

:

PLO

T D

ATE:

SHEET OF

5/7/

2 015

10:1

9 :54

AM

FORT

CA

RSO

N, C

OLO

RAD

OPN

8 135

7 (F

Y 15)

04/0

6/20

15

W91

28F-

15-R

-004

7

-

OMAHA DISTRICT

J.W

HIS

LER

III

K.R

EPAS

KEY

W.B

OEC

K

Ent

er F

ile N

ame

F211

-10-

08

S-001

OM

AHA

DIS

TRIC

TO

MAH

A , N

EBR

ASK A

K.C

HAN

00

GE N

ERA

L ST

RUC

T UR

AL

NO

TES

4TH

ID C

A B, U

AS H

ANG

AR

S-0

01-

I. DESIGN LOADS

A. DEAD LOAD (IN ADDITION TO FRAMING SELF WEIGHT)1) ROOF (ADMINISTRATIVE AREA) = 25 PSF2) ROOF (ADMINISTRATIVE AREA ABOVE MECHANICAL ROOM) = 42 PSF3) ROOF (MAINTENANCE AREA):

a) PEMB ROOF = 22 PSFb) COLLATERAL = 20 PSFc) 5-TON CRANE

5) ROOF (AIRCRAFT CONTAINER STORAGE) = 15 PSF6) ROOF (ORGANIZATIONAL STORAGE BUILDING) = TBD BY DESIGNER7) SECOND FLOOR (INCLUDING 10 PSF OVERPOUR) = 79 PSF8) SECOND FLOOR ABOVE MECHANICAL ROOM (INCLUDING 10 PSF OVERPOUR) = 96 PSF9) SECOND FLOOR ABOVE SHOPS (INCLUDING 10 PSF OVERPOUR) = 81 PSF

B. LIVE LOAD1) ROOF CONSTRUCTION LIVE LOAD = 20 PSF (ALL BUILDINGS)2) ROOF LIVE LOAD = 20 PSF (REDUCIBLE - ALL BUILDINGS)3) FIRST AND SECOND MECHANICAL AND ELECTRICAL ROOMS = 125 PSF4) SECOND FLOOR JANITORIAL, ADMIN/FACILITY STORAGE, LIGHT STORAGE,

AND TELECOM ROOMS = 125 PSF5) SECOND FLOOR ELSEWHERE = 100 PSF7) STAIRS AND ELEVATOR LOBBY = 100 PSF (300 LB POINT LOAD)8) SLAB-ON-GRADE = 100 PSF (HS-20 AXLE POINT LOAD IN MAINTENANCE AREA)

C. WIND LOAD1) BASIC WIND SPEED = 127 MPH ( 3 SECOND GUST)2) EXPOSURE CATEGORY = C3) IMPORTANCE FACTOR = 1.04) INTERNAL PRESSURE COEFFICIENTS, GCpi:

a) ADMINISTRATION AREA (ENCLOSED) = 0.18, -0.18b) MAINTENANCE AREAS AND FIRE SUPPRESSION ROOM (PARTIALLY ENCLOSED) = 0.55, -0.55c) AIRCRAFT CONTAINER STORAGE (PARTIALLY ENCLOSED) = 0.55, -0.55d) ORG. STORAGE BUILDING (PARTIALLY ENCLOSED) = 0.55, -0.55

5) ROOF AND WALL COMPONENTS AND CLADDING: SEE WIND LOAD DIAGRAMS

D. SNOW LOAD1) GROUND SNOW = 15 PSF2) IMPORTANCE FACTOR = 1.03) EXPOSURE FACTOR = 1.04) THERMAL FACTOR = 1.0, 1.2 AT ROOF OVERHANGS, CANOPIES, AND AIRCRAFT CONTAINER STORAGE5) SNOW DENSITY, GAMMA = 16 PSF6) SLOPE FACTOR = 1.07) UNBALANCED, SLIDING, AND DRIFT: SEE SNOW LOAD DIAGRAMS8) BASED ON LOCAL PRACTICE, DESIGN ROOF SNOW LOADS SHALL NOT BE LESS

THAN THOSE BASED ON PIKES PEAK REGIONAL BUILDING CODE (PPRBC); PPRBC REQUIRES A MINIMUM FLAT ROOF SNOW LOAD OF 30 PSF.

E. SEISMIC LOAD1) SEISMIC DESIGN CATEGORY B2) OCCUPANCY CATEGORY: II3) Ss = 0.184) S1 = 0.065) SITE CLASS D6) IMPORTANCE FACTOR = 1.07) SDS = 0.1928) SD1 = 0.0969) BASIC SEISMIC FORCE RESISTING SYSTEMS:

a) HANGAR MAINTENANCE AREAS: STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE (BRACED/MOMENT FRAMES)b) HANGAR ADMINISTRATION AREA AND AIRCRAFT CONTAINER STORAGE: BEARING WALL SYSTEMS, INTERMEDIATE REINFORCED MASONRY SHEAR WALLS AND ORDINARY PRECAST SHEAR WALLS.c) ORGANIZATIONAL STORAGE BUILDING: STEEL SYSTEMS NOT SPECIFICALLY DETAILED FOR SEISMIC RESISTANCE.d) FIRE SUPPRESSION ROOM: ORDINARY PRECAST SHEAR WALLS.

10) DESIGN BASE SHEARS:a) ADMINISTRATIVE AREA = 312 KIPSb) MAINTENANCE AREA = ( PER PEMB SUPPLIER)c) AIRCRAFT CONTAINER STORAGE = 25 KIPSd) ORG. STORAGE BUILDING = (PER PEMB SUPPLIER)

11) SEISMIC RESPONSE COEFFICIENTS;a) ADMINISTRATIVE AREA = 0.064b) MAINTENANCE AREAS = 0.064c) AIRCRAFT CONTAINER STORAGE = 0.064d) ORG. STORAGE BUILDING = 0.064

12) RESPONSE MODIFICATION COEFFICIENTS:a) ADMINISTRATION AREA = 3b) MAINTENANCE AREAS = 3c) AIRCRAFT CONTAINER = 3d) ORG. STORAGE BUILDING = 3

II. GENERAL NOTES A. REFERENCE ELEVATION 100'-0" = TOP OF FIRST FLOOR FINISHED SLAB FOR BOTH THE ADMIN AND HANGAR, SEE CIVIL SHEETS FOR MEAN SEA LEVEL ELEVATION.

B. THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND COORDINATE LOCATIONS OF ALL EMBEDDED ITEMS, CONDUITS, PIPES, AND OPENINGS. REFER TO ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ITEMS NOT INDICATED ON STRUCTURAL DRAWINGS. THE CONTRACTING OFFICER SHALL BE NOTIFIED IMMEDIATELY OF ANY DISCREPANCY.

C. THE CONTRACTOR SHALL PROVIDE AND MAINTAIN ADEQUATE BRACING AND SHORING FOR STEEL AND PRECAST CONCRETE WORK AT ALL TIMES DURING CONSTRUCTION.

D. THE CONTRACTOR SHALL BE RESPONSIBLE FOR FIRESTOPPING ALL GAPS BETWEEN WALLS AND OVERLYING FLOORS, DECKING, AND STRUCTURE AS WELL AS OTHER PENETRATIONS AS REQUIRED BY ARCHITECTURAL, MECHANICAL, AND ELECTRICAL SHEETS, AND BY THE CONTRACT SPECIFICATIONS.

E. ANTI-TERRORISM/FORCE PROTECTION (AT/FP):1) MECHANICAL EQUIPMENT, ELECTRICAL EQUIPMENT, AND ARCHITECTURAL COMPONENTS REQUIRE SPECIAL AT/FP BRACING AND SUPPORT. SEE SPECIFICATION SECTIONS:

13 48 00: SEISMIC PROTECTION FOR MISCELLANEOUS EQUIPMENT13 48 00.00 10: SEISMIC PROTECTION FOR MECHANICAL EQUIPMENT

26 05 48.00 10: SEISMIC PROTECTION FOR ELECTRICAL EQUIPMENT

2) COMPONENTS AND SYSTEMS IN EXTERIOR WALLS OF THE ADMINISTRATION AND SHOPS AREAS OF THE BUILDING (NOT HANGAR BAYS) SHALL BE DESIGNED AND DETAILED PER UFC 04-010-01 AND 04-010-02 (LATEST VERSION) TO PROVIDE A LOW LEVEL OF PROTECTION FOR THE STANDOFF DISTANCE SHOWN ON THE CIVIL DRAWINGS.

3) EXTERIOR WINDOWS, WINDOW FRAMES, AND WINDOW FRAME ANCHORAGE REQUIRE AT/FP BLAST MITIGATION DESIGN AND DETAILS. SEE SPECIFICATION SECTIONS:

08 51 13: ALUMINUM WINDOWS08 81 00: GLAZING

4) EXTERIOR STOREFRONT GLAZING, STOREFRONT FRAME AND STOREFRONT FRAME ANCHORAGE REQUIRE AT/FP BLAST MITIGATION DESIGN AND DETAILS. SEE SPECIFICATION SECTION:

08 41 13: ALUMINUM - FRAMED ENTRANCE AND STOREFRONTS

5) EXTERIOR DOORS AND DOOR ANCHORAGE REQUIRE AT/FP BLAST MITIGATION DESIGN AND DETAILS. SEE SPECIFICATION SECTION:

08 11 16: ALUMINUM DOORS AND FRAMES

6) COORDINATE FASTENING OF EXTERIOR WINDOW FRAMES, CURTAIN WALL FRAMES, AND DOORS TO PRECAST WALL PANELS WITH THE PRECAST SUPPLIER.

IV. REINFORCED CONCRETE

A. DESIGN CODES: BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE (ACI-318)

B. MATERIAL STRENGTHS:

1) CONCRETE COMPRESSIVE STRENGTH (f'c) AT 28 DAYS NORMAL WEIGHT:

ITEM f'c FREEZE THAWEXPOSURE

CLASS

SULFATEEXPOSURE

CLASS

PERMEABILITY CORROSIONPROTECTION

INTERIOR SLAB-ON-GRADE (UNO),INTERIOR FOOTINGS, ELEVATED

SLABS, AND ARMS VAULTS

INTERIOR SLAB-ON-GRADE ATHANGAR BAY - SEE NOTE IV.C.13

INTERIOR SLAB-ON-GRADE AT ALLIED SHOP (#119),BENCH STOCK/TECH SUPPLY (#118), SECURED

STORAGE (#118A), UNIT STORAGE OFFICE (#117),CORRIDOR 4 (COR-4), AND STAIR 2 (ST-2)

ALL OTHER CONCRETE

4.0 KSI

5.0 KSI

4.5 KSI

FO SO PO C1

FO SO PO C1

FO SO PO C1

FO SO PO C1

2) REINFORCING STEEL: BARS (NOT WELDED) ASTM A615, GR. 60 KSI BARS (WELDED) ASTM A706, GR. 60 KSI TIES ASTM A615, GR. 60 KSI WELDED WIRE REINFORCEMENT ASTM A185

C. NOTES1) ALL CONCRETE OPERATIONS AND REINFORCEMENT SHALL BE IN ACCORDANCE WITH THE LATEST ACI AND CRSI STANDARDS.2) REFER TO THE ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS FOR ADDITIONAL EMBEDDED ITEMS AND ACCESSORIES. NO CALCIUM CHLORIDE OR OTHER DELETERIOUS SALTS ARE PERMITTED IN CONCRETE. NO ALUMINUM EMBEDMENTS ARE PERMITTED. PROVIDE 3/4" CHAMFER AT ALL EXPOSED CORNERS.3) FURNISH THE FOLLOWING CONCRETE COVER ON REINFORCING BARS UNO: SLAB ON GRADE 1.5" COVER AT TOP SLABS ON METAL FORMS CENTER MESH IN PORTION

OF SLAB ABOVE METAL FORMS COLUMN PEDESTALS 2" COVER ON TIES FOUNDATIONS 3" COVER ON BOTTOM AND SIDES WALLS 2" UNO4) PROVIDE THE FOLLOWING CONCRETE FINISHES UNO: WALLS PER SPECIFICATIONS FOUNDATIONS PER SPECIFICATIONS SLABS TO BE EXPOSED PER ARCH STAIRS AND RAMPS, EXTERIOR PER ARCH STAIRS AND RAMPS, INTERIOR PER ARCH5) LONGITUDINAL REINFORCING IN THE FOUNDATION SHALL BE PLACED CONTINUOUS AT CORNERS AND INTERSECTIONS. MATCHING CORNER BARS SHALL BE USED PER THE TYPICAL CONCRETE REINFORCEMENT DETAILS ON THE CONTRACT DRAWINGS.6) ALL CONCRETE IS REINFORCED UNLESS SPECIFICALLY CALLED OUT AS UNREINFORCED. REINFORCE ALL CONCRETE NOT OTHERWISE SHOWN WITH SAME STEEL AS IN SIMILAR SECTIONS OR AREAS.7) ALL ADJOINING SURFACES NOT CAST MONOLITHICALLY SHALL BE INTENTIONALLY ROUGHENED TO 1/4" AMPLITUDE AT EXISTING CONCRETE SURFACE FOR THE ENTIRE INTERSECTING SURFACE. APPLY BONDING AGENT TO EXISTING CONCRETE PRIOR TO PLACING NEW CONCRETE.8) CONTRACTOR SHALL COORDINATE LOCATIONS OF ALL FLOOR DRAINS, FLOOR FINISHES, CURBS, CONCRETE PADS, AND SLAB DEPRESSIONS WITH ARCHITECTURAL AND MECHANICAL DRAWINGS.9) CONTRACTOR SHALL FIELD VERIFY DIMENSIONS AND LOCATIONS OF ALL OPENINGS, PIPE SLEEVES, CURBS, ETC. AS REQUIRED WITH OTHER TRADES PRIOR TO PLACING CONCRETE.10) CONTRACTOR SHALL COORDINATE LOCATIONS OF INSERTS, WELDED PLATES, AND OTHER ITEMS EMBEDDED IN CONCRETE WITH ARCHITECTURAL DRAWINGS, MECHANICAL DRAWINGS, AND OTHER TRADES.11) ALL SLABS SHALL BE FLAT AND LEVEL PER SPECIFICATIONS. CONTRACTOR SHALL INCLUDE IN THE BID ANY EXCESS CONCRETE REQUIRED DUE TO SUPPORT MEMBER DEFLECTION TO ACHIEVE FLAT AND LEVEL SLABS. THE CONCRETE PLACING PROCEDURE SHALL BE CONTROLLED TO MINIMIZE MEMBER DEFLECTION.12) ALL REINFORCING BARS SHALL BE LAPPED AS SPECIFICALLY DETAILED ON THE DRAWINGS. REFERENCE SPLICE AND EMBEDMENT SCHEDULE PER THE TYPICAL CONCRETE DETAILS. WHERE NOT SPECIFICALLY DETAILED ON THE DRAWINGS, ALL REINFORCING BARS SHALL BE LAPPED USING THE TENSION LAPPED SPLICE LENGTHS IN THE LAP SPLICE SCHEDULE. TERMINATE BARS AT DISCONTINUOUS ENDS WITH STANDARD HOOKS, UNLESS NOTED OTHERWISE.13) HANGAR BAY PAVEMENT SHALL MEET REQUIREMENT OF 32 13 11.10 PER HANGAR BAY CONCRETE SPECIFICATIONS.

VI. STRUCTURAL STEEL

A. DESIGN CODE: SPECIFICATIONS FOR THE DESIGN, FABRICATION, AND ERECTION OF STRUCTURAL STEEL FOR BUILDINGS (AISC).

B. MATERIAL STRENGTHS:

STRUCTURAL STEEL ROLLED W-SHAPES ASTM A992, (FY = 50 KSI) CHANNELS, ANGLES, AND OTHER HOT ROLLED SHAPES ASTM A36 BASEPLATES AND ALL OTHER MISC. PLATES & BARS ASTM A36 STRUCTURAL STEEL TUBING ASTM A500, GR. B (FY = 46 KSI) STRUCTURAL PIPE ASTM A53, GR. B CONNECTION BOLTS ASTM A325 ANCHOR RODS ASTM F1554, GR. 36 WELDING ELECTRODES E70

C. NOTES:

1) UNLESS INDICATED OTHERWISE, ALL BOLTED CONNECTIONS SHALL BE 3/4 INCH DIAMETER A325N. ALL BOLT SPACING SHALL BE 3" AND ALL BOLT EDGE DISTANCES SHALL BE 1 1/4" MINIMUM UNLESS OTHERWISE INDICATED ON THE CONTRACT DRAWINGS.2) ALL STRUCTURAL STEEL AND THEIR CONNECTIONS SHALL BE DETAILED, FABRICATED, AND ERECTED ACCORDING TO THE LATEST VERSION OF THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION (AISC) MANUAL OF STEEL CONSTRUCTION.3) EXPANSION ANCHORS FOR INSTALLATION INTO CONCRETE SHALL BE HILTI TZ OR APPROVED EQUAL.4) STRUCTURAL STEEL TO BE PAINTED OR GALVANIZED PER SPECIFICATIONS.5) ALL WELDING TO BE DONE BY AMERICAN WELDING SOCIETY (AWS) CERTIFIED WELDERS.6) COLUMN ANCHOR RODS SHALL BE POSITIVELY LOCATED USING 1/8" SHEET METAL

TEMPLATES FOR ALL COLUMN BASEPLATES. PROVISION SHALL BE MADE FOR ALL ANCHOR RODS TO BE RIGIDLY HELD IN POSITION TO PREVENT MOVEMENT DURING CONCRETE PLACEMENT. ANCHOR RODS SHALL NOT BE TIGHTENED PRIOR TO 14 DAYS FOLLOWING CONCRETE PLACEMENT.

7) PORTIONS OF THE STRUCTURE ARE NOT SELF SUPPORTING DURING ERECTION; FOR GRAVITY AS WELL AS LATERAL LOADS. PROVIDE ANY TEMPORARY BRACING OR GUYS TO PROVIDE A LATERAL SUPPORT OF THE BUILDING AND INDIVIDUAL ELEMENTS UNTIL PERMANENT FRAME AND DECK ARE COMPLETELY INSTALLED. ALL LATERAL LOAD RESISTANCE AND STABILITY OF THE BUILDING IN THE COMPLETED STRUCTURE IS PROVIDED EXCLUSIVELY BY STEEL BRACED FRAMES. THE COMPOSITE METAL DECK, CONCRETE FLOORS AND ROOF DECK SERVE AS HORIZONTAL DIAPHRAGMS THAT DISTRIBUTE THE LATERAL WIND AND SEISMIC FORCES HORIZONTALLY TO THE STEEL BRACED FRAMES. BRACED FRAMES CARRY THE APPLIED LATERAL LOADS TO THE BUILDING FOUNDATION.8) STRUCTURAL STEEL SHALL NOT BE RELEASED FOR FABRICATION UNTIL THE PRECAST

CONCRETE WALL PANEL SHOP DRAWINGS HAVE BEEN APPROVED AND THE FINAL WALL PANEL THICKNESS VERIFIED.

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

3A

M #

000

3 - G

ENER

AL R

EVI

SIO

NS

05/0

8/20

15

VII. STEEL JOISTS

A. STEEL JOISTS SHALL CONFORM TO THE 2010 STANDARD SPECIFICATIONS OF THE STEEL JOIST INSTITUTE (SJI).

B. JOIST BRIDGING SIZE, SPACING, AND LOCATIONS SHALL BE DETERMINED BY THE JOIST SUPPLIER.

C. CONCENTRATED LOADS FROM MECHANICAL AND ELECTRICAL EQUIPMENT, AS WELL AS FROM ARCHITECTURAL COMPONENTS SHALL, SHALL BE LOCATED AT JOIST PANEL POINTS WHERE PRACTICAL. WHERE NOT PRACTICAL, EXTRA JOIST WEB MEMBERS SHALL BE FIELD LOCATED AND INSTALLED AT LOCATIONS WHERE CONCENTRATED LOADS FROM MECHANICAL AND ELECTRICAL EQUIPMENT, AS WELL AS FROM ARCHITECTURAL COMPONENTS, EXCEED 50 POUNDS. COORDINATE PROCUREMENT, LOCATIONS, AND INSTALLATION OF EXTRA JOIST WEB MEMBERS WITH JOIST SUPPLIER.

D. JOISTS LOCATED ADJACENT ON BOTH SIDES OF STEEL COLUMNS THAT ARE NOT FRAMED WITH STRUCTURAL STEEL MEMBERS RUNNING PARALLEL TO THE JOISTS SHALL BE FIELD BOLTED AT JOIST BEARINGS.

E. LOCATIONS AND DETAILS OF JOIST BRIDGING CONNECTIONS TO PRECAST CONCRETE PANELS SHALL BE COORDINATED WITH PRECAST SUPPLIER TO AVOID INTERFERENCE WITH PRECAST PANEL TENDONS AND REINFORCEMENT.

F. CONTRACTOR SHALL COORDINATE WITH MECHANICAL AND ELECTRICAL CONTRACTORS AND PROVIDE JOIST SUPPLIER THE WEIGHTS AND LOCATIONS OF ANY COMPONENTS OR EQUIPMENT SUPPORTED FROM THE JOISTS OF 50 POUNDS OR LARGER.

G. STEEL JOISTS SHALL NOT BE RELEASED FOR FABRICATION UNTIL THE PRECAST CONCRETE WALL PANEL SHOP DRAWINGS HAVE BEEN APPROVED AND THE FINAL WALL PANEL THICKNESS VERIFIED.

VIII. STEEL ROOF DECK AND COMPOSITE FLOOR DECK:

A. DESIGN CODE: STEEL DECK INSTITUTE DESIGN MANUAL FOR ROOF DECKS AND FLOOR DECKS (SDI)

B. MATERIAL STRENGTHS: PER SDI SPECIFICATIONS

C. NOTES:

1) STEEL ROOF DECK AND COMPOSITE FLOOR DECK SHALL BE DESIGNED, FABRICATED, AND ERECTED ACCORDING TO SPECIFICATIONS OF THE STEEL DECK INSTITUTE (SDI).2) PROVIDE ALL RIDGE AND VALLEY PLATES, SUMP PANS, CLOSURE PLATES, POUR STOPS, AND ALL OTHER ACCESSORIES REQUIRED FOR COMPLETE INSTALLATION.3) ALLOWABLE STRESS BASED ON SDI AND AISI.4) MAXIMUM DEFLECTION DUE TO SUPERIMPOSED LOADS SHALL BE LIMITED TO L/240.5) STEEL ROOF DECK AND COMPOSITE FLOOR DECK TO BE GALVANIZED PER CONTRACT DOCUMENTS.6) PROVIDE ROOF DECK CONSTRUCTION THAT IS LISTED AND CONFORMS TO THE UL FIRE RESISTANCE DIRECTORY AND BUILDING MATERIALS DIRECTORY. DECK ATTACHMENT SHALL MEET A CLASS 1-90 UPLIFT RATING.7) ALL METAL DECK SHALL BE FABRICATED AND INSTALLED FOR A MINIMUM TWO SPAN CONDITION, UNO. TEMPORARY SHORING OF METAL DECK SHALL NOT BE USED UNLESS APPROVED BY THE CONTRACTING OFFICER.8) DECKING CONTRACTOR SHALL COORDINATE DECK OPENING SIZES AND LOCATIONS WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL DRAWINGS AND SHALL PROVIDE HEADER MEMBERS AND REINFORCEMENT AS REQUIRED PER TYPICAL DETAILS.9) REFERENCE THE CONTRACT DRAWINGS FOR DECK TYPE, GAUGE, AND FASTENER SPACING.10) COMPOSITE METAL FLOOR DECK HANGER TAB LOADS SHALL NOT EXTEND 60 LBS PER HANGER TAB. LOADS SHALL BE DISTRIBUTED SUCH THAT THE TRIBUTARY LOAD SHALL NOT EXCEED 5 PSF. MECHANICAL EQUIPMENT SHALL NOT BE HUNG FROM METAL DECK. HANGING LOADS FROM ROOF DECK IS PROHIBITED.

III. FOUNDATIONS & SOIL DATA (PER GEOTECHNICAL REPORT)

A. FOUNDATIONS WILL BE DESIGNED IN ACCORDANCE WITH REQUIREMENTS SET FORTH IN THE FINAL FOUNDATION ANALYSIS FOR THE UNMANNED AIRCRAFT SYSTEMS (UAS) HANGAR BUTTS ARMY AIRFIELD, FORT CARSON, COLORADO, DATED 3 JUNE 2014.

B. THE FOUNDATION SYSTEM CONSISTS OF CONTINUOUS WALL FOOTINGS, AND SPREAD FOOTINGS. THE MINIMUM DEPTH TO THE BOTTOM OF THE FOOTINGS IS 36" BELOW ADJACENT FINISH GRADE EXTERIOR FOOTINGS, UNLESS NOTED OTHERWISE. THE NET ALLOWABLE BEARING CAPACITY IS 2500 PSF FOR SPREAD AND CONTINUOUS WALL FOOTINGS PER THE GEOTECHNICAL REPORT.

C. REFER TO THE GEOTECHNICAL REPORT/CIVIL SPECIFICATION FOR PLACEMENT OF FILL UNDER FOUNDATIONS, FILL PRECONSOLIDATION REQUIREMENTS, AND FILL REQUIRED PROPERTIES. A 6" THICK CAPILLARY WATER BREAK CONSISTING OF GRANULAR MATERIAL SHALL BE PLACED UNDER ALL INTERIOR CONCRETE SLABS-ON-GRADE. A 15 MIL VAPOR BARRIER SHALL BE PLACED DIRECTLY UNDER ALL INTERIOR CONCRETE SLABS-ON-GRADE WITH THE EXCEPTION OF THE HANGAR BAYS. 2" THICK HIGH DENSITY RIGID UNDER SLAB INSULATION SHALL BE PLACED DIRECTLY UNDER THE HANGAR BAY SLABS-ON-GRADE AND OVER THE 15 MIL VAPOR BARRIER.

C. ALL COMPACTED FILL INSTALLATION SHALL BE INSPECTED AND APPROVED BY A REGISTERED GEOTECHNICAL ENGINEER. A REGISTERED GEOTECHNICAL ENGINEER SHALL INSPECT AND APPROVE BEARING MATERIALS PRIOR TO THE PLACEMENT OF CONCRETE.

D. BACKFILL AROUND FOUNDATION WALLS SHALL BE PLACED ON EACH SIDE OF THE WALL IN EQUAL LIFTS.

IX. COLD FORMED STEEL FRAMING

A. COLD FORMED STRUCTURAL STEEL FRAMING SHALL CONFORM TO THE MOST CURRENT ADOPTED EDITION OF THE AMERICAN IRON AND STEEL INSTITUTE (AISI) "DESIGN OF COLD FORMED STEEL STRUCTURAL MEMBERS".

B. REFER TO SPECIFICATION SECTION 05 40 00 FOR REQUIREMENTS.

X. REINFORCED CONCRETE MASONRY

A. DESIGN CODES: IBC 2012 AND ACI1530-11 "BUILDING CODE REQUIREMENTS FOR MASONRY STRUCTURES"

B. MATERIAL STRENGTHS:1) CMU BLOCK STRENGTH (NORMAL WEIGHT) = 1900 PSI2) MORTAR STRENGTH = 1800 PSI MINIMUM @ 28 DAYS3) MASONRY STRENGTH (F'm) = 1500 PSI @ 28 DAYS4) CONCRETE FILL (GROUT) STRENGTH = 2500 PSI @ 28 DAYS5) REINFORCEMENT BARS = ASTM A615, GR. 60 KSI6) HORIZONTAL JOINT REINFORCEMENT = ASTM A82, GALVANIZED

C. NOTES:

1) PROPER BLOCK TYPE SHALL BE USED (OPEN END, BOND BEAM, ETC.) AS REQUIRED TO COMPLETE THE CONSTRUCTION AS SHOWN ON THE CONSTRUCTION DOCUMENTS.

2) CONCRETE FILL (GROUT) SHALL HAVE A MAXIMUM AGGREGATE SIZE OF 3/8", GROUT ONLY CELLS WITH HORIZONTAL OR VERTICAL REINFORCEMENT UNLESS NOTED OTHERWISE.

3) HORIZONTAL JOINT REINFORCEMENT SHALL BE GALVANIZED LADDER TYPE,UNO, CONFORMING TO ASTM A82. PLACE HORIZONTAL JOINT REINFORCEMENT AT 16" O.C. ABOVE GRADE.

4) PROVIDE THE FOLLOWING MINIMUM LAP LENGTHS: #4 = 36", #5 = 45", #6 = 54" FOR REINFORCING BARS. STAGGER HORIZONTAL LAPS. EXTEND HORIZONTAL BARS AROUND CORNERS 24" MINIMUM.

5) ALIGN CMU VERTICAL CELLS TO BE FILLED WITH GROUT TO PROVIDE CONTINUOUS UNOBSTRUCTED VERTICAL CELLS. REMOVE OVERHANGING MORTAR AND OTHER OBSTRUCTIONS AND DEBRIS FROM THE CELL WALLS.

6) VERTICAL REINFORCEMENT SHALL BE SECURED IN PLACE PRIOR TO PLACEMENT OF GROUT USING BAR POSITIONERS SPACED NOT GREATER THAN 10 FEET O.C. LOCATE ONE BAR POSITIONER MINIMUM AT EACH VERTICAL REINFORCING LAP. VERTICAL REINFORCING SHALL HAVE A MINIMUM GROUT COVER 1/2" TO THE INSIDE FACE OF THE CMU AND A MINIMUM TOTAL COVER INCLUDING MASONRY OF 2 INCHES.

7) GROUTING SHALL STOP 1 1/2" BELOW THE TOP OF A COURSE TO FORM A KEY AT THE JOINT.

8) GROUT SHALL BE MECHANICALLY CONSOLIDATED USING A VIBRATOR WITH A MINIMUM 3/4" HEAD DIAMETER.

9) IF FOUNDATION DOWELS DO NOT LINE UP WITH VERTICAL CMU CELL, DO NOT SLOPE DOWEL GREATER THAN ONE HORIZONTAL IN SIX VERTICAL. IF SLOPE EXCEEDS ONE IN SIX, PROVIDE NEW DOWEL EMBEDDED INTO CONCRETE WITH HILTI HIT HY-150 MAX ADHESIVE (OR APPROVED EQUAL). CONTACT CONTRACTING OFFICER FOR PROPER EMBEDMENT OF REINFORCING INTO CONCRETE FOUNDATION. INSTALL UNDER CONTINUOUS INSPECTION.

10) PIPING OR CONDUIT EMBEDDED IN REINFORCED MASONRY SHALL NOT EXCEED 1 INCH IN DIAMETER AND LOCATION SHALL BE SUBJECT TO APPROVAL BY ARCHITECT/ENGINEER.

11) ANCHOR BOLTS, EMBEDMENTS, WALL INSERTS, ETC. SHALL BE GROUTED SOLID IN POSITION.

12) FURNISH REINFORCED CELLS CONTINUOUS FULL HEIGHT OF WALL AT ALL JAMBS AND CORNERS. REFER TO THE CMU LINTEL SCHEDULE AND THE CMU WALL REINFORCING DETAILS.

13) UNLESS NOTED OTHERWISE OR DETAILED, ALL OPENINGS IN MASONRY SHALL HAVE REINFORCED LINTELS PER SCHEDULE.

14) CONTROL JOINTS IN MASONRY WALLS SHALL BE LOCATED AS INDICATED IN THE SPECIFICATIONS, UNO.

15) CONTRACTOR SHALL COORDINATE LOCATIONS OF ALL REQUIRED WALL OPENINGS AND PENETRATIONS WITH ARCHITECTURAL, MECHANICAL, AND ELECTRICAL PLANS AND SPECIFICATIONS.

XI. METAL BUILDING SYSTEM

A. THE FOUNDATION SYSTEM FOR THE HANGAR BAY HAS BEEN DESIGNED BASED ON ASSUMED PEMB COLUMN REACTIONS SHOWN ON SHEET S-611. FINAL PEMB REACTIONS FROM THE PEMB SUPPLIER ARE REQUIRED TO VERIFY THAT THE FOUNDATION IS ADEQUATE. THE CONTRACTOR SHALL OBTAIN THE SERVICES OF A LICENSED PROFESSIONAL ENGINEER TO VERIFY THE FOUNDATIONS, FINAL PEMB COLUMN REACTIONS, AND SOIL PARAMETERS SPECIFIED IN NOTE III ON S-001 ARE ADEQUATE FOR THE BUILDING SUPPLIED. ANY REVISIONS TO THE FOUNDATIONS SHALL BE AT NO ADDITIONAL COST TO THE GOVERNMENT, AND SHALL BE SUBMITTED TO THE GOVERNMENT FOR APPROVAL PRIOR TO CONSTRUCTION. ITEMS OTHER THAN THE METAL BUILDING COLUMN FOUNDATIONS SHALL BE CONSTRUCTED AS SHOWN. THE TOP FOOTING REINFORCEMENT AS SHOWN ON S-610 SHALL BE MAINTAINED AS A MINIMUM FOR THOSE FOOTINGS WHICH WILL HAVE BOLLARDS ATTACHED PER SECTION 4/S-514.

B. THE FOUNDATION SYSTEM FOR THE ORGANIZATIONAL STORAGE BUILDING IS PRELIMINARY AND TO BE USED FOR BIDDING PURPOSES ONLY. THE CONTRACTOR SHALL ENLIST THE SERVICES OF A PROFESSIONAL ENGINEER TO COMPLETE THE FINAL DESIGN OF THE FOUNDATIONS (BASEPLATES, SPREAD FOOTINGS, FOOTING REINFORCEMENT, TIE-BARS, AND ANCHOR BOLTS). ENGINEER SHALL DESIGN THE FOUNDATION BASED UPON BUILDING COLUMN REACTIONS PROVIDED BY THE METAL BUILDING MANUFACTURER.

C. THE MAXIMUM LATERAL DRIFT OF THE STEEL FRAMES AT THE EAVE SHALL NOT EXCEED h/400 FOR HANGAR BAY AND h/240 FOR THE ORGANIZATIONAL STORAGE BUILDING. "h" IS DEFINED AS THE FRAME HEIGHT FROM THE FINISHED FLOOR ELEVATION TO THE TOP OF THE EAVE STRUT. THE LATERAL DRIFT (SIDESWAY) OF THE STRUCTURE, EVALUATED USING 10-YEAR WIND LOADS, SHALL PROVIDE FOR THE SERVICEABILITY OF THE STRUCTURE AND ALL OF ITS COMPONENTS, INCLUDING BUT NOT LIMITED TO EXTERIOR WALLS AND CLADDING, PARTITION WALLS, HANGAR DOORS, BRIDGE CRANES, UTILITIES, AND OTHER APPURTTENANCES.

D. THE CONTRACTOR SHALL PROVIDE THE METAL BUILDING SYSTEM SUPPLIER THE WEIGHT AND APPROXIMATE LOCATION OF ALL CONCENTRATED LOADS (MECHANICAL AND FIRE PROTECTION UNITS, PIPES, HANGERS) GREATER THAN 50 LBS.

E. THE LATERAL SUPPORT SYSTEMS SHALL BE AS SPECIFIED IN 13 34 19 AND AS SHOWN ON THE DESIGN DRAWINGS.

F. NEITHER THE STANDING SEAM METAL ROOF OR STRUCTURAL STEEL DECKING SHALL BE USED AS A DIAPHRAGM TO TRANSFER LATERAL LOADS.

G. THE CONTRACTOR IS RESPONSIBLE FOR THE DESIGN OF SUPPORT FOR ALL MECHANICAL, ELECTRICAL, PLUMBING, AND FIRE PROTECTION ITEMS.

H. THE METAL BUILDING SYSTEM SUPPLIER IS RESPONSIBLE FOR DESIGNING AND PROVIDING FRAMING FOR SUPPORT OF A 5-TON BRIDGE CRANE. COORDINATE WITH CRANE SUPPLIER FOR LOADS AND LOCATIONS OF CRANE SUPPORT HANGERS, RAILS, AND ATTACHMENT LOCATIONS OF LONGITUDINAL AND LATERAL BRACING.

I. FIXED BASE COLUMNS ARE NOT ALLOWED.

J. THE METAL BUILDING SYSTEM SUPPLIER IS RESPONSIBLE FOR DESIGNING AND PROVIDING FRAMING AND SUPPORT FOR THE SLIDING HANGAR DOORS.

V. PRECAST CONCRETE WALL PANELS

A. PRECAST CONCRETE WALL PANELS SHALL BE INSULATED STRUCTURAL PANELS OF THE THICKNESSES SHOWN ON THE DRAWINGS. ANY CHANGES IN THICKNESS SHALL BE REVIEWED AND APPROVED BY THE DOR.

B. THE PRECAST WALL PANELS SHALL BE DESIGNED FOR THE LOADS INDICATED ON THE CONTRACT DRAWINGS.

C. THE PRECAST PANEL SUPPLIER SHALL BE RESPONSIBLE FOR THE DESIGN AND DETAILING OF ALL EMBED PLATES, CONNECTIONS BETWEEN PRECAST PANELS, AND ANCHORAGE TO THE FOUNDATION IN ACCORDANCE WITH THE APPLICABLE PROVISIONS OF THE AMERICAN CONCRETE INSTITUTE ACI 318-08/318R-08 BUILDING CODE REQUIREMENTS FOR STRUCTURAL CONCRETE AND COMMENTARY AND/OR THE PRECAST/PRESTRESSED CONCRETE INSTITUTE (PCI) DESIGN HANDBOOK - PRECAST AND PRESTRESSED CONCRETE, 6TH EDITION (2004). THE PRECAST WALL PANEL SUPPLIER SHALL COORDINATE WITH THE STRUCTURAL STEEL SUPPLIER FOR MOMENTS DUE TO BEAM CONNECTION ECCENTRICITY AND OTHER ECCENTRIC LOADS TO BE CONSIDERED FOR DESIGN OF THE EMBEDDED PLATES IN THE WALL PANELS.

D. THE LOCATION AND INSTALLATION OF PRECAST PANEL ANCHORAGES AND ERECTION BRACING SHALL BE COORDINATED WITH OTHER TRADES.

E. PRECAST PANELS SHALL BE BRACED UNTIL ROOF AND FLOOR DECKS ARE IN PLACE AND SECURED. THE CONTRACTOR SHALL COORDINATE TEMPORARY BRACE LOCATIONS SO AS NOT TO INTERFERE WITH OTHER TRADES.

F. CONCRETE FOR PRECAST WALL PANELS SHALL BE NORMAL WEIGHT CONCRETE WITH A MINIMUM 28-DAY COMPRESSIVE STRENGTH OF 5000 PSI.

G. PRECAST PANELS SHALL BE REINFORCED, EITHER PRESTRESSED OR NON-PRESTRESSED.

XII. SPECIAL INSPECTION

A. PROVIDE SPECIAL INSPECTIONS IN ACCORDANCE WITH CHAPTER 17, SECTIONS 1704 & 1705 OF THE 2012 INTERNATIONAL BUILDING CODE FOR THE FOLLOWING AREAS:

1) STEEL CONSTRUCTION - SECTION 1705.22) CONCRETE CONSTRUCTION - SECTION 1705.33) SOILS - SECTION 1705.64) SPECIAL INSPECTIONS FOR WIND RESISTANCE - SECTION 1705.105) MASONRY CONSTRUCTION - SECTION 1705.4

B. INCLUDE SPECIAL INSPECTION REQUIREMENTS IN CONTRACTOR'S QUALITY CONTROL (CQC) PLAN.

H. THE PRECAST CONCRETE WALL PANELS AND THEIR CONNECTIONS SHALL BE DESIGNED PER UFC 04-010-01 AND 04-010-02 TO PROVIDE A LOW LEVEL OF PROTECTION FOR AT/FP. REFER TO THE CIVIC DRAWINGS FOR STAND OFF DISTANCE TO BE CONSIDERED.

I. SEE SPECIFICATION SECTION 03 45 33; PRECAST AND PRECAST/PRESTRESSED STRUCTURAL CONCRETE FOR ADDITIONAL INFORMATION.

3

Page 6: EXTENSION ARM DETAILS€¦ · type fe6 - chain-link fence w/barbed-wire on single outrigger type fe5 - chain-link fence without barbed-wire apron fence legend: examples: fabric width

EL: SEE PLANT/ FOOTING

EL: VARIEST/ HANGAR SLAB

T/ PEDESTALEL: 98'-8"

EL: 98'-8" UNOT/FOOTING

EL: 100'-0"T/SLAB

SLAB-ON-GRADE,ELEV. VARIES SEE PLANS

98' - 8"REFER TO 1/S-510FOR SUBBASEREQUIRED UNDERSLAB-ON-GRADE

NOTES:1. TIE BEAM REINFORCING SPLICES SHALL BE FULLY DEVELOPED WELDED SPLICES OR FULLY DEVELOPED MECHANICAL SPLICES.

2. PROVIDE #3 TIES AT 18" O.C.

(6) - #8(CONT.)

6" 4" 4" 6"

6"8"

6"

GRID

T/ TIE BEAMEL:

2 LAYERS30# FELT

SLAB-ON-GRADESEE PLAN

(2) #5 BOT. CONT.

#4 DOWELS @ 12" O.C.

#4 HORIZ. EACH FACE@ 12" O.C.

TYP.

8"

8"2'

- 0"

8" 2' - 0"SEE PLAN

3' -

8"1'

- 4"

#6 @ 12"O.C. EA. WAYTOP & BOT.

8" CMU WALLSEE PLAN AND CMUWALL SCHEDULE FORREINFORCEMENT

BON

D B

EAM

CO

NTI

NU

OU

S

CONT. WATERSTOPPLACED ON THE OUTSIDEFACE OF THE DOWEL TYP.AROUND PERIMETER. SEESPECS

#4 HORIZ. EA. FACE@ 12" O.C.

#4 DOWELS @ 12" O.C.

(2) #5 BOT. CONT

8" SEE PLAN2-#4 Z BARSEACH WAY

CONT. WATERSTOPPLACED ON THE OUTSIDEFACE OF THE DOWEL TYP.AROUND PERIMETER. SEESPECS

3

1

100' - 0"T.O. SLABEL:

DAMPPROOFING FOURSIDES OF PIT WALLSSEE SPECIFICATIONS

8

NOTES:1. HANGAR DOOR RAIL, LEVELER, AND LEVELING BOLTS ARE PER HANGAR DOOR SUPPLIER.2. SEE HANGAR DOOR SUPPLIER FOR CONCRETE GROOVE/CHAMFER REQUIREMENTS AT RAIL.3. CONTINUE SLAB-ON-GRADE REINFORCEMENT INTO BLOCKOUT. PLACE REINFORCEMENT IN CONFLICT WITH LEVELER BELOW LEVELER AS SHOWN.4. SEE HANGAR DOOR SUPPLIER FOR WIDTH OF BLOCKOUT.5. SEE 1/S-302 FOR EXTERIOR PRECAST HANGAR CONTINUOUS FOOTING SIZE AND REINFORCEMENT.6. CONTRACTOR TO COORDINATE SLAB THICKNESS AT DOOR LOCATION WITH RAIL, LEVELER, AND LEVELING BOLT REQUIREMENTS.7. STARTING AT BUILDING FACE, SLOPE CONCRETE AWAY FROM BUILDING (0.75% SLOPE) TO MATCH CIVIL PAVEMENT SLOPE AND ELEVATIONS.8. CONTRACTOR SHALL VERIFY DIMENSIONS MAY VARY PER HANGAR DOOR MANUFACTURER. CONTRACTOR SHALL COORDINATE DIMENSIONS AND CLEARANCES OF HANGAR DOOR WITH STRUCTURAL ELEMENTS ALONG COLUMN LINE 8 PRIOR TO FABRICATION OF METAL BUILDING.

WWF 6x6xw2.1/2.1(FLAT SHEETS ONLY

HANGAR DOORSEE ARCH.

RADIANT TUBINGRE: MECH DWGSFOR ADDITIONALINFORMATION

THICKENED EDGE EXPANSIONJOINT PER SHEET CP522

10"

6 3/4"

7"7"3"

COL. BLOCKOUT

#4 @12" O.C. EA.WAY AT TOP

SEE SCHEDULE FOR FTGTHICKNESS AND REINF

COLUMN BASEPLATE,GROUT, AND ANCHORAGEBY METAL BUILDINGMANUFACTURER

PEMB COLUMNSEE SUPPLIERMAX DEPTH = 14"

PRECAST CONCRETEWALL PANEL. SEEARCH. FOR FINISH

JOINT: RE CIVIL

PAVEMENT: RE CIVIL

2" HIGH DENSITY EXTRUDEDPOLYSTYRENE INSULATION (R-10 MIN.)

STD EMBED PLCONN PER PRECASTSUPPLIER

10"

96' - 8"

HANGAR SLAN-ON-GRADERE: PLAN FOR THICKNESSAND REINF

W (NOTE: SEE FOOTING SCHEDULE FOR SIZE AND REINFORCEMENT)

W/2 W/2

T/ FTGEL:

#5 @ 12" O.C. EAWAY T&B

1' -

2"

2' - 8"

10" WIDE CONCRETEFOUNDATION WALL W/#5 @ 12" O.C.E.W.EACH FACE

CONC. PEDESTAL SEESCHEDULE FOR REINF.

1/2" THICK PREFORMEDCOMPRESSIBLE JOINTFILLER W/ SEALANT

10" 1' - 6 3/4"

NOTE 8

1' - 5"

NOTE 8

5' - 5 1/4"

MIN.

11 3/4"

10' - 1"

HJ

NOTE: SEE FOOTING SCHEDULE FOR SIZE AND REINFORCEMENT

W

W/2 W/2

JOINT3" ISOLATION

1' - 1"

3" 3" 7"

CONCRETE TIE BEAMREINF. SHALL EXTENDA MIN. OF 6" BEYOND ANCHORBOLTS AND SHALL TERMINATEWITH A STANDARD 90 DEG.HOOK. SEE SECTION 2/S-303

EDGE OF SPREADFOOTING BEYOND

PEMB COLUMN, BASEPLATE, AND ANCHORAGE.SEE SUPPLIER

CONCRETE BLOCKOUT

1/2" THICK PREFORMEDCOMPRESSION JOINT FILLER

SLAB-ON-GRADE. SEE PLAN

PRECAST CONCRETEWALL BY PRECASTSUPPLIER. SEE ARCH.

2 LAYERS 30# FELT

STANDARD EMBED PLATECONNECTION PERPRECAST DESIGN

D

PLAN VIEW

HOOK BARSAROUND ANCHORBOLTS

SHEETIDENTIFICATION

1 2 3 4 5

DR

AWN

BY:

DES

I GN

BY:

SBM

T BY

:

SIZ

E :FI

LE N

AM

E:

ISSU

E D

ATE

:

CO

NTR

ACT

NO

.:

SO

LIC

ITAT

ION

NO

.:

US

ARM

Y C

OR

PS O

F EN

GIN

EER

S

CKD

BY:

US Army Corps ofEngineers ®

22" x

34"

D

C

B

A

FILE

NU

MBE

R:

PLO

T SC

ALE

:

PLO

T D

ATE:

SHEET OF

3/4

" = 1

'-0"

5/7/

2 015

10:1

9 :57

AM

FORT

CA

RSO

N, C

OLO

RAD

OPN

8 135

7 (F

Y 15)

04/0

6/20

15

W91

28F-

15-R

-004

7

-

OMAHA DISTRICT

J.W

HIS

LER

III

J.W

HIS

LER

III W.B

OEC

K

Ent

er F

ile N

ame

F211

-10-

08

S-303

- -

OM

AHA

DIS

TRIC

TO

MAH

A , N

EBR

ASK A

K.C

HAN

0

FOU

N DA

TIO

N S

E CTI

ON

S A

ND

DET

AIL

S

4TH

ID C

A B, U

AS H

ANG

AR

S-3

03-

3/4" = 1'-0"S-3032 TYPICAL TIE BEAM SECTION

0

SCALE: 3/4"=1'-0"

12 2

3/4" = 1'-0"S-3033 ELEVATOR PIT FOUNDATION SECTION

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

3A

M #

000

3 - G

ENER

AL R

EVI

SIO

NS

05/0

8/20

15

3/4" = 1'-0"S-3034

SPREAD FOOTING AT HANGARBAY COLUMN NEAR DOOR

3/4" = 1'-0"S-3031 SPREAD FOOTING AT ISOLATION JOINT

3

Page 7: EXTENSION ARM DETAILS€¦ · type fe6 - chain-link fence w/barbed-wire on single outrigger type fe5 - chain-link fence without barbed-wire apron fence legend: examples: fabric width

SEE PLANT/FOOTING

SEE PLANT/SLAB

T/ STEM WALLEL: 98'-8"

T/ FOOTINGEL: SEE PLAN

T/ SLAB & PITEL: 99'-10"

T/FTGEL: VARIES, SEE PLAN

T/CONC.EL: 98'-8" U.N.O.

T/SLABEL: 100'-0" U.N.O.

T/FOOTINGEL: SEE PLAN

T/PEDESTALEL: 98'-8"

T/SLABEL: SEE PLAN EL: 110'-0"

T/ PRECAST

EL: 98'-8"T/ PEDESTAL

EL: 100'-0"T/ SLAB

R

PRECAST CONCRETEWALL BY PRECASTSUPPLIER. SEE ARCH

EXTERIOR GRADE ORPAVEMENT. RE: CIVIL

PEMB COLUMNBY METAL BUILDINGMANUFACTURER

1/2" THICK PREFORMEDCOMPRESSIBLE JOINTFILLER W/ SEALANT

CONCRETE TIE BEAMREINF. SHALL EXTENDA MIN. OF 6" BEYOND ANCHORBOLTS AND SHALL TERMINATEWITH A STANDARD 90 DEG.HOOK.

EDGE OF PEMBFOOTING BEYOND

CONCRETE BLOCKOUT

SLAB-ON-GRADESEE PLAN

2" THICK HIGH DENSITY EXTRUDEDPOLYSTYRENE INSULATION (R-10 MIN.)

NOTE: SEE FOOTING SCHEDULE FOR SIZE AND REINFORCEMENT

W

W/2 W/2

10" 1" GAP

STANDARD EMBED PLATECONNECTION PERPRECAST DESIGN

PLAN VIEW

HOOK BARSAROUND ANCHORBOLTS

JOINT; RE: CIVIL

6.1

2' - 0"

2' -

0"

L2 1/2x1 1/2x3/16xCONTW/ 1/2" DIA. X 4" LONGHEADED STUDS @ 18" O.C.

CONC. SLAB,SEE PLAN

DAMPPROOFING FOURSIDES OF PIT WALLSSEE SPECIFICATIONS

INSULATION,SEE SPECS

CONT. WATERSTOPCENTER IN WALLTYPICAL AROUNDPERIMETER

(2)-#4 Z BARSEA WAY

#6 T&B EA,WAY @ 12" O.C.

#5 DOWELS TO MATCHVERT REINF. PROVIDESTD HOOKS IN FTGS

#5 HORIZ. @ 12" O.C.EA. WAY, EA. FACE OFPIT. PROVIDE MATCHINGCORNER BARS

#5 VERT REINF. @ 12" O.C.EA. FACE, TYP.

6" MIN WIDTH EMBED PLATEBY PRECAST SUPPLIER.3 PLATES WITHIN GRATINGAREA

L4x4x1/4 CONT

PRECAST CONC.WALL BY PRECASTSUPPLIER, SEE ARCHDWGS

STD EMBED PLATECONN. PER PRECASTDESIGN

STEEL GRATINGW-19-4 (1"x3/16") @ C1W-19-4 (1 1/2"x3/16 @ C2

EXTERIOR GRADE,SEE CIVIL DWGS

#30 FELT

1

3

#6 @ 12" O.C.

0' -

8"

2' - 0" 1' - 0"1' - 0"

4' - 10"

1' -

4"

6" 3" 3"

R

(3) - #6 CONT.

2' - 0"

2' -

0"

CONNECTION BY PRECASTCONCRETE SUPPLIER

FOUNDATION WALL10" WIDE CONCRETE

PRECAST WALLPANEL BY PRECASTSUPPLIER. SEEARCH. FOR LAYOUT

CONC. SLABSEE PLAN

1/2" THICK PREFORMEDCOMPRESSIBLE JOINTFILLER W/ SEALANT

#5 @ 12" O.C.E.W.EACH FACE

R

PRECAST CONCRETEWALL BY PRECASTSUPPLIER. SEE ARCH

EXTERIOR GRADE ORPAVEMENT. RE: CIVIL

PEMB COLUMNBY METAL BUILDINGMANUFACTURER

1/2" THICK PREFORMEDCOMPRESSIBLE JOINTFILLER W/ SEALANT

CONCRETE TIE BEAMREINF. SHALL EXTENDA MIN. OF 6" BEYOND ANCHORBOLTS AND SHALL TERMINATEWITH A STANDARD 90 DEG.HOOK.

CONCRETE BLOCKOUT

SLAB-ON-GRADESEE PLAN

2" THICK HIGH DENSITY EXTRUDEDPOLYSTYRENE INSULATION (R-10 MIN.)

10"

STANDARD EMBED PLATECONNECTION PERPRECAST DESIGN

PLAN VIEW

HOOK BARSAROUND ANCHORBOLTS

PEDESTAL. SEEFOUNDATION PLANFOR PEDESTAL MARKING.SEE S-610 FOR PEDESTALREINFORCEMENT

FOOTING. SEE ISOLATEDFOOTING SCHEDULEON SHEET S-610 FORREINFORCEMENT

1" GAP

NOTE: SEE FOOTING SCHEDULE FOR SIZE AND REINFORCEMENT

W

W/2 W/2

EDGE OF STEM-WALLBEYOND PEDESTAL

JOINT; RE: CIVIL

P

1/2" THICK PREFORMEDCOMPRESSIBLE JOINTFILLER W/ SEALANT

CONCRETE BLOCKOUT.SEE PLANS AND DETAILSFOR HANGAR RAILCONDITIONS ANDREINFORCEMENT

GRID

GIRT BY PEMBSUPPLIER

METAL PANEL BYOTHERS

STRUCTURAL SUPPORT CONNECTION OFPRECAST WALL TO COLUMN BY PEMB SUPPLIER.DESIGN FOR AN OUT-OF-PLANE UNFACTOREDWIND LOAD OF POS. OR NEG. 300 PLF. THE 0.7FACTOR PER IBC TABLE 1604.3 FOOTNOTE "f" ISALLOWED TO BE USED IN DETERMINING LATERALDEFLECTION. COORDINATE CONNECTION WITHPRECAST DESIGNER.

CONNECTION BY PRECASTCONCRETE SUPPLIER

PRECAST WALL PANELBY PRECAST SUPPLIER.SEE ARCH FOR LAYOUT

HANGAR DOOR SLAB.SEE S-302 FOR SECTIONCUTS AT HANGAR DOORS

SEE PLANS AND FOOTINGSCHEDULE FOR FOOTINGSIZE AND REINFORCEMENT

2' - 0"

10" 1' - 2"

8" MIN. X CONTINUOUS EMBED PLATE ALONGTOP OF WALL BY PRECAST SUPPLIER.

PEMB COLUMN, BASE PLATE,AND ANCHORAGE. SEE SUPPLIER

X-BRACING BYPEMB MANUFACTURER

1/2" THICK PREFORMEDCOMPRESSIBLE JOINTFILLER

COLUMN PEDESTALSEE PLAN

SHEETIDENTIFICATION

1 2 3 4 5

DR

AWN

BY:

DES

I GN

BY:

SBM

T BY

:

SIZ

E :FI

LE N

AM

E:

ISSU

E D

ATE

:

CO

NTR

ACT

NO

.:

SO

LIC

ITAT

ION

NO

.:

US

ARM

Y C

OR

PS O

F EN

GIN

EER

S

CKD

BY:

US Army Corps ofEngineers ®

22" x

34"

D

C

B

A

FILE

NU

MBE

R:

PLO

T SC

ALE

:

PLO

T D

ATE:

SHEET OF

3/4

" = 1

'-0"

5/7/

2 015

10:2

0 :01

AM

FORT

CA

RSO

N, C

OLO

RAD

OPN

8 135

7 (F

Y 15)

04/0

6/20

15

W91

28F-

15-R

-004

7

-

OMAHA DISTRICT

J.W

HIS

LER

III

J.W

HIS

LER

III W.R

. BO

ECK

F211

-10-

08

S-304

OM

AHA

DIS

TRIC

TO

MAH

A , N

EBR

ASK A

K.C

HAN

0

FOU

N DA

TIO

N S

E CTI

ON

S A

ND

DET

AIL

S

4TH

ID C

A B, U

AS H

ANG

AR

S-3

04-

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

3A

M #

000

3 - G

ENER

AL R

EVI

SIO

NS

05/0

8/20

15

3/4" = 1'-0"S-3041 SECTION

0

SCALE: 3/4"=1'-0"

12 2

3/4" = 1'-0"S-3042 FIRE SUPPRESSION ROOM PIT

3/4" = 1'-0"S-3045

CONC. FOUNDATION WALLAT APPARATUS BAY

3/4" = 1'-0"S-3043 SECTION

3/4" = 1'-0"S-3044 SECTION

3

Page 8: EXTENSION ARM DETAILS€¦ · type fe6 - chain-link fence w/barbed-wire on single outrigger type fe5 - chain-link fence without barbed-wire apron fence legend: examples: fabric width

TYPE VLT

AS S

CH

EDU

LED

SCHED

AS

CLASS 5 VAULT

TYPE N

AS S

CH

EDU

LED

SCHED

AS

4'-0

" MAX

2'-6

"

NARROW LITE

GL-2 (GL-3 INFIRE-RATEDDOORS)

4"

TYPE G

AS S

CH

EDU

LED

SCHED

AS

6" 2'-0" 6"

HALF GLASS

GL-2

6"2'

-9"

TYPE FG

AS S

CH

EDU

LED

SCHED

AS

FULL GLASSMEDIUM STILE

GL-2

TYPE OH

SECTIONAL OVERHEAD DOOR

AS SCHEDULED

AS S

CED

ULE

D

OF

GLA

ZIN

G

MIN

. 6'-0

" TO

BO

TTO

M

TYPE A

AS S

CH

EDU

LED

DO

OR

TYP

AN

D S

IZE

2"

2"

SCHED

AS 2"

TYPE B

AS S

CH

EDU

LED

DO

OR

TYP

AN

D S

IZE

4"2"

SCHED

AS 2"

TYPE C7'

-0"

2"

2"

SCHED

AS 2"

TYPE D

7'-0

"4"

4" AS SCHEDULED 4"

TYPE E1

2'-4

"2"

7'-0

"

2" 3'-0" 2" 2'-6" 2"

6'-0"

4"

GLAZING

TYPE WM

AS S

CH

EDU

LED

SCHED

AS

WIRE MESH

TYPE E2

2"7'

-0"

2" 3'-0" 2" 1'-2" 2"

4'-8"

4"

GL-2

TYPE F

AS S

CH

EDU

LED

SCHED

AS

FLUSH

TYPE SC

SERVICE COUNTER

AT P

REC

AST

3'-6

" A

.F.F

.

AT C

MU

3'-4

" A.F

.F.

2'-6" 15'-0" 2'-6"

3'-6

"6'

-0"

EQEQ

EQ EQ

20'-0" +/-

HANGAR DOOR PANEL

W7

HANGAR DOOR NOTES:1. WINDOWS TO BE SIZED TOALIGN WITH METAL PANELS AND TOFIT WITH ANY REQUIRED FRAMINGFOR DOORS. SEE WINDOWSCHEDULE FOR GLAZING TYPE.2. SEE SHEET A-702 FOR DOORJAMB AND HEADER DETAILS.3. SEE STRUCTURAL DRAWINGSFOR SILL/FOOTING CONDITIONS.

20'-4

" +/

-

TYPE C

COILING OVERHEAD DOOR

AS SCHEDULED

AS S

CH

EDU

LED

SHEETIDENTIFICATION

1 2 3 4 5

DR

AWN

BY:

DES

I GN

BY:

SBM

T BY

:

SIZ

E :FI

LE N

AM

E:

ISSU

E D

ATE

:

CO

NTR

ACT

NO

.:

SO

LIC

ITAT

ION

NO

.:

US

ARM

Y C

OR

PS O

F EN

GIN

EER

S

CKD

BY:

US Army Corps ofEngineers ®

22" x

34"

D

C

B

A

FILE

NU

MBE

R:

PLO

T SC

ALE

:

PLO

T D

ATE:

SHEET OF

As

indi

cate

d

5/6/

2 015

1:05

: 56

PM

PN8 1

357

(FY 1

5)04

-06-

2015

W91

28F-

15-R

-004

7

-

OMAHA DISTRICT

KAJ

/ DVM

KAJ

/ DVM

BRG

F211

-10-

08

A-610

OM

AHA

DIS

TRIC

TO

MAH

A , N

EBR

ASK A

BRG

0

DO

OR

SCH

E DU

LE

4TH

ID C

AB

, UA

S HA

NG

AR

FORT

CA

RSO

N, C

OLO

RAD

O

A-6

10- FRAME TYPES

NOT TO SCALE

DOOR TYPESNOT TO SCALE

DOOR SCHEDULE

MARK LOCATION

DOORFIRE

RATING

FRAME DETAILS

HARDWARE NOTESTYPESIZE

MAT'L FINISH TYPE MAT'L FINISH HEAD JAMB SILLWIDTH HEIGHT100A VESTIBULE/EXT. FG 3'-0" 7'-0" ALUM KYNAR E1 ALUM KYNAR 1/A-700 1/A-700 2/A-700 HW-1.1 1100B VESTIBULE FG 3'-0" 7'-0" ALUM KYNAR E1 ALUM KYNAR 1/A-700 2/A-700 SIM. HW-2.0101 MAINTENANCE PLATOON N 3'-0" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-24 5

101A MAINTENANCE PLATOON N 3'-0" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-4.0 5101B MAINTENANCE PLATOON N 3'-0" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-4.0 5102 FLIGHT SIMULATOR F 3'-6" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-36.0 1, 5103 CLS/LARS N 3'-0" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-37.0 1, 5

103A GBO OFFICE N 3'-0" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-4.0 5104 BREAK RM N 3'-0" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-3.0105 GBSAA CLOSET F 3'-0" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-37.0106 ELEVATOR EQUIP. F 3'-0" 7'-0" STL PNT 3/4 HR A STL PNT 7/A-700 8/A-700 HW-12.0107 QC/QA N 3'-0" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-37.0 1, 5108 RECYCLE F 3'-0" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-9.0109 MAIN TELECOM ROOM F 3'-0" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-38.0 1110 PRODUCTION CONTROL N 3'-0" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-39.0 1, 5111 SMALL TOOLS F 3'-4" 7'-0" STL PNT D STL PNT 5/A-700 6/A-700 HW-15.0

111A SMALL TOOLS SC 4'-0" 4'-0" STL PNT 3/4 HR PER MFR STL PNT PER MFR PER MFR PER MFR 2, 3112 JANITOR F 3'-0" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-10.0113 ARMS VAULT VLT 3'-4" 6'-8" STL PNT PER MFR STL PNT PER MFR PER MFR PER MFR 4114 MEN'S RESTROOM F 3'-0" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-35.0115 WOMEN'S RESTROOM F 3'-0" 7'-0" STL PNT A STL PNT 7/A-700 8/A-700 HW-35.0116 ELECTRICAL ROOM F 3'-6" 7'-0" STL PNT A STL PNT 5/A-700 6/A-700 HW-26.0117 UNIT STORAGE OFFICE N 6'-0" 7'-0" STL PNT 1 HR D STL PNT 5/A-700 6/A-700 HW-18.0 PAIR, 7118 BENCH STOCK/TECH SUPPLY N 3'-0" 7'-0" STL PNT B STL PNT 5/A-700 6/A-700 HW-8.0

118A BENCH STOCK/TECH SUPPLY F 6'-0" 7'-0" STL PNT D STL PNT 5/A-700 6/A-700 HW-14.0 1, 6118B BENCH STOCK/TECH SUPPLY C 10'-0" 10'-0" STL PNT 3/4 HR PER MFR STL KYNAR 1/A-701 2/A-701 PER MFR118C BENCH STOCK/TECH SUPPLY SC 4'-0" 4'-0" STL PNT PER MFR STL KYNAR PER MFR PER MFR PER MFR ROLL UP ISSUE COUNTER118D BENCH STOCK/TECH SUPPLY N 3'-0" 7'-0" STL PNT B STL PNT 5/A-700 6/A-700 HW-5.0119 ALLIED SHOP N 3'-0" 7'-0" STL PNT 3/4 HR A STL PNT 3/A-700 4/A-700 HW-25.0

119A ALLIED SHOP C 10'-0" 10'-0" STL PNT 3/4 HR PER MFR STL KYNAR 1/A-701 2/A-701 PER MFR119B ALLIED SHOP N 3'-0" 7'-0" STL PNT A STL PNT 3/A-700 4/A-700 HW-20.0 1119C ALLIED SHOP C 10'-0" 10'-0" STL PNT PER MFR STL KYNAR 1/A-701 2/A-701 PER MFR120 MECHANICAL ROOM F 6'-0" 7'-0" STL PNT C STL PNT 3/A-700 4/A-700 HW-16.0 PAIR, 7121 COMPRESSOR F 6'-0" 7'-0" STL PNT D STL PNT 5/A-700 6/A-700 HW-23.0 PAIR122 MAIN ELECTRICAL ROOM F 6'-0" 7'-0" STL PNT C STL PNT 3/A-700 4/A-700 HW-19.0 PAIR, 1, 7

123A HANGAR N 3'-0" 7'-0" STL PNT A STL PNT 3/A-700 4/A-700 HW-20.0 1123B HANGAR N 3'-0" 7'-0" STL PNT A STL PNT 3/A-700 4/A-700 HW-20.0 1123C HANGAR N 3'-0" 7'-0" STL PNT A STL PNT 3/A-700 4/A-700 HW-20.0 1123D HANGAR N 3'-0" 7'-0" STL PNT A STL PNT 3/A-700 4/A-700 HW-20.0 1123E HANGAR N 3'-0" 7'-0" STL PNT A STL PNT 3/A-700 4/A-700 HW-20.0 1123F HANGAR N 3'-0" 7'-0" STL PNT A STL PNT 3/A-700 4/A-700 HW-20.0 1124A FIRE SUPPRESSION F 3'-0" 7'-0" STL PNT A STL PNT 3/A-700 4/A-700 HW-32.0124B FIRE SUPPRESSION C 10'-0" 10'-0" STL PNT PER MFR STL KYNAR 1/A-701 2/A-701 PER MFR

COR-3 CORRIDOR 3 N 3'-0" 7'-0" STL PNT 3/4 HR A STL PNT 3/A-700 4/A-700 HW-7.0COR-4 CORRIDOR 4 N 6'-0" 7'-0" STL PNT 3/4 HR C STL PNT 3/A-700 4/A-700 HW-22.0 PAIRST-1A STAIR 1/EXT. FG 3'-0" 7'-0" ALUM KYNAR E ALUM KYNAR 1/A-700 2/A-700 HW-1.0 1ST-1B STAIR 1/INT. N 3'-0" 7'-0" STL PNT 1 HR B STL PNT 5/A-700 6/A-700 HW-29.0ST-2A STAIR 2/EXT. N 6'-0" 7'-0" STL PNT 1 HR C STL PNT 3/A-700 4/A-700 HW-21.0 PAIR, 1, 7ST-2B STAIR 2/INT. N 6'-0" 7'-0" STL PNT 1 HR D STL PNT 5/A-700 6/A-700 HW-22.0 PAIR, 7ST-3A STAIR 3/EXT. N 3'-0" 7'-0" STL PNT A STL PNT 3/A-700 4/A-700 HW-20.0 1ST-3B STAIR 3/INT. N 3'-0" 7'-0" STL PNT 1 HR A STL PNT 3/A-700 4/A-700 HW-30.0 8

201 CORRIDOR 6 FG 3'-0" 7'-0" WD STAIN E2 STL PNT 2/A-700 HW-6.0201A SAFETY N 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-4.0 5201B CONFERENCE N 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-4.0 5201C STANDARDS N 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-4.0 5201D STORAGE F 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-13.0201E RECYCLE F 3'-0" 7'-0" WD STAIN C STL PNT 7/A-700 8/A-700 HW-9.0201F 1ST SGT. N 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-4.0 5201G CO. CMDR. N 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-4.0 5201H XO OFFICE N 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-4.0 5202 FLIGHT PLATOON OFFICE N 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-37.0 1, 5

202A FLIGHT PLATOON 1 N 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-4.0 5202B FLIGHT PLATOON 2 N 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-4.0 5202C FLIGHT PLATOON 3 N 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-4.0 5203 MULTI-PURPOSE TRNG RM N 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-6.0 5

204A STORAGE F 6'-0" 7'-0" WD STAIN - C STL PNT 7/A-700 8/A-700 HW-17.0 PAIR204B BRIEFING ROOM F 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-27.0 5204C BRIEFING ROOM F 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-27.0 5205 TELECOM F 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-38.0 1206 SIPR F 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-31.0 ICIDS207 FLIGHT PLANNING N 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-37.0 1, 5

207A FLIGHT OPS G 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-6.0208 WOMEN'S ROOM F 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-35.0209 JANITOR F 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-10.0210 MEN'S ROOM F 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-35.0211 ELECTRICAL F 3'-0" 7'-0" WD STAIN 3/4 HR A STL PNT 7/A-700 8/A-700 HW-28.0212 UNIT STORAGE F 3'-0" 7'-0" WD STAIN A STL PNT 7/A-700 8/A-700 HW-13.1213 TA-50 GEAR STORAGE F 6'-0" 7'-0" STL PNT C STL PNT 7/A-700 8/A-700 HW-34.0 PAIR, 7

213A COMM STORAGE WM 3'-0" 7'-0" WM PNT PER MFR STL PNT PER MFR FRAME BY PARTITION MFR213B NBC STORAGE WM 3'-0" 7'-0" WM PNT PER MFR STL PNT PER MFR FRAME BY PARTITION MFRST-1C STAIR 1 N 3'-0" 7'-0" STL PNT 1 HR B STL PNT 5/A-700 6/A-700 HW-29.0ST-2C STAIR 2 N 6'-0" 7'-0" STL PNT 1 HR D STL PNT 5/A-700 6/A-700 HW-33.0 PAIR, 7ST-3C STAIR 3 N 3'-0" 7'-0" STL PNT 1 HR B STL PNT 5/A-700 6/A-700 HW-29.0

DOOR TYPE GENERAL NOTES:

1. SEE WINDOW SCHEDULE FOR GLAZING TYPES.2. ALL EXTERIOR DOORS WITH GLAZING TO HAVE GL-1.3. ALL FIRE RATED DOORS WITH GLAZING SHALL HAVE GL-3.4. ALL OTHER DOORS SHALL HAVE GL-4.

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

3A

M. #

0003

GE

NER

AL

RE

VISI

ON

S05

-08-

15

DOOR SHEDULE NOTES:

1. KEYLESS ENTRY2. SHELF TO CLEAR STRUCTURAL CROSS BRACING . SEE WALL SECTION 1 ON A-400.3. ROLL-UP DOOR TO AUTOMATICALLY ROLL DOWN WHEN FIRE ALARM IS ACTIVATED.4. PROVIDE DOOR WITH DAY GATE.5. STC-33 RATED DOOR AND FRAME6. DOOR AND HARDWARE TO MEET ARMY REGULATION 190-51, APPENDIX B, PARAGRAPH B-2 a. FOR RISK LEVEL 1.7. PROVIDE REMOVABLE MULLION8. PROVIDE SIGN ON PUSH SIDE OF DOOR THAT SAYS, "NOT AN EXIT".

3

Page 9: EXTENSION ARM DETAILS€¦ · type fe6 - chain-link fence w/barbed-wire on single outrigger type fe5 - chain-link fence without barbed-wire apron fence legend: examples: fabric width

B.O. TUBE12'-0" A.F.F.

ROOF HATCH FLASHING

MEMBRANE ROOF SYSTEM

PREFABRICATED INSULATED DOORROOF HATCH WITH INTEGRATEDRAILING. DOOR SHALL OPEN 70DEG. MIN. WHEN FULLY OPEN.

ROOF MEMBRANE FLASHING,EXTEND TO 8" HEIGHT MIN.

PREFABRICATED INSULATEDMETAL ROOF CURB

STEEL FRAMING -SEE STRUCTURAL

AUTOMATIC HOLD-OPEN ANDOPERATING ARMS, ONE EA. SIDE

ACOUSTICAL CEILING TILEWHERE NOTED ON FINISHSCHEDULE

GYP. BD. CEILING TILEWHERE NOTED ON FINISHSCHEDULE

5/8" GYP. BD.

STEEL ANGLE ANCHORAT 6'-0" O.C. MAX.

7"STEEL OR WOOD BLOCKINGAT EACH ANCHOR POINT

1'-0

" O.C

.

METAL DECK

ROOF SUBSTRATE, INSULATION,AND TOPPING BOARD

SPRAY FOAM INSULATION

SUPPORT FRAMINGFOR HATCH

STUD WALL FRAMING

STEEL RUNG

STEEL ANGLE ANCHORAT BASE

INTUMESCENT PAINT OR FIRE CAULKWHERE SPRAY FOAM IS EXPOSED

ROOF HATCH GUARD RAILINTEGRAL WITH HATCH

STEEL ANGLE FRAMINGPER STRUCTURAL DWGS.

TUBULAR DAYLIGHTINGDEVICE W/ PRISMATIC DOME -INSTALL PER MANUFACTURERINSTRUCTIONS

PRISMATIC DIFFUSER

CUT DECK TO FIT TUBULARSKYLIGHT RATHER THANSQUARE OPENING

PER MFR.

CRICKET

1'-0"

@ H

IGH

PT.

MIN

. 2" C

RIC

KET

MIN

.

1'-4

"

PROVIDE FIRESTOPPINGMATERIAL BETWEENSTEEL DECK ANDTUBULAR SKYLIGHT

SEE WALL SECTIONS FORROOF CONSTRUCTION

CONTINUE ROOF MEMBRANEUP AND OVER CURB

AT HIGH END

4"

METAL FLASHING PERSKYLIGHT MFR

LINE OF FRAMING

METAL STUD FRAMING TOACCOMMODATE SKYLIGHTDOME AND FLASHING. FILLVOID WITH SPRAY FOAM TOMAINTAIN ROOF R-VALUEAND AIR BARRIER

1/2" SHEATHING FORROOF FLASHING

FILL VOID WITH SPRAYFOAM TO MAINTAIN ROOF R-VALUE AND AIR BARRIER

CRICKET

DUAL-GLAZED DOMESKYLIGHT

PLAN VIEW

1/2" CDX PLYWOOD

4'-0" PANEL WIDTH

3"

212

3'-9"

CONT. BLOCKING

SKYLIGHT FLASHINGBY SKYLIGHT MFR.

INSULATED TRANSLUCENTSKYLIGHT PANEL

STANDING SEAM METALROOF- CONTINUE METALUP CURB AND LAPPEDWITH SKYLIGHT FLASHING

STANDING SEAMMETAL ROOF

PEMB PURLIN BEYOND

AIR TIGHT AND WATERTIGHT SEALANT ON ALLSKYLIGHT EDGES

AIR / VAPOR TO CONINUEUP AND OVER CURB

METAL FRAMINGBY PEMB MFR.

3

1/2" CDX PLYWOOD

CONT. BLOCKING

SKYLIGHT FLASHING BYSKYLIGHT MFR.

INSULATED TRANSLUCENTSKYLIGHT PANEL

STANDING SEAMMETAL ROOF

PEMB PURLIN

(MFR. STANDARD)

SKYLIGHT PANEL

2" ALUM. BATTEN PERMFR. - SEAL ALL EDGES

STEEL DECK

RIGID INSULATION CRICKET

3"

AIR / VAPOR BARRIERCONTINUED UP AND OVER CURB.

METAL FLASHING UP CURB ANDLAPPED WITH SKYLIGHT FLASHING.COLOR TO MATCH ROOF.

EDGE OF SKYLIGHT BEYOND

AIR TIGHT AND WATERTIGHT SEALANT AT ALLSKYLIGHT EDGES

1"1"

1" MIN

4"ELSEWHERE

SIZE AS SHOWN4"

2"2"

DOWNSPOUT

STRAP TWO-PIECE

WASHER

DRILL FOR 1/4"DIA BOLT IN EXP.ANCHOR - SEENOTE

1/4" DIA. X 5/8" BOLT -BRASS, ALUM. ORSTAINLESS STEEL

5/16" X 1/8" SLOTTEDHOLE EA. SIDE

ELSEWHERE

SIZE AS SHOW

N

OPEN FACEDDOWNSPOUT

DOWNSPOUT STRAP

NOTEl PROVIDE A MINIMUM OF 2DOWNSPOUT STRAPS PER DOWNSPOUTOR AT 6'-0" O.C. MAX.

2"

PEMB EAVE138'-0"

HJ

3'-6

"1'

-0"

TYP.

1'-0

"

METAL PANELS

GUTTER

3/4" DIA. STEELBAR RUNG

2-1/2" X 3/8" STEELBAR SIDE RAILS

STEEL BAR GRATEPLATFORM

7"

STEEL SUPPORT W/1/2" EXP. ANCHORW/ 2" EMBEDMENT

A-4021

SIM.

NOTE: PAINT ALLSTEEL PNT-12

SHEETIDENTIFICATION

1 2 3 4 5

DR

AWN

BY:

DES

I GN

BY:

SBM

T BY

:

SIZ

E :FI

LE N

AM

E:

ISSU

E D

ATE

:

CO

NTR

ACT

NO

.:

SO

LIC

ITAT

ION

NO

.:

US

ARM

Y C

OR

PS O

F EN

GIN

EER

S

CKD

BY:

US Army Corps ofEngineers ®

22" x

34"

D

C

B

A

FILE

NU

MBE

R:

PLO

T SC

ALE

:

PLO

T D

ATE:

SHEET OF

As

indi

cate

d

5/6/

2 015

12:2

8 :12

PM

PN8 1

357

(FY 1

5)04

-06-

2015

W91

28F-

15-R

-004

7

-

OMAHA DISTRICT

Des

igne

r

Aut

hor

App

rove

r

F211

-10-

08

A-705

OM

AHA

DIS

TRIC

TO

MAH

A , N

EBR

ASK A

Che

cker

0

RO

OF

DET A

ILS

4TH

ID C

AB

, UA

S HA

NG

AR

FORT

CA

RSO

N, C

OLO

RAD

O

A-7

05-

MAR

KD

ESC

RIP

TIO

ND

ATE

APPR

3A

M. #

0003

GE

NER

AL

RE

VISI

ON

S05

-08-

15

1" = 1'-0"A-7051 ROOF ACCESS HATCH 1" = 1'-0"A-705

2 TUBULAR DAYLIGHTING DEVICE

1 1/2" = 1'-0"A-7054 SKYLIGHT DETAIL

1 1/2" = 1'-0"A-7055 SKYLIGHT DETAIL 2

3" = 1'-0"A-7053 TYPICAL DOWNSPOUT DETAIL

1" = 1'-0"A-7056 ROOF LADDER