44
H CORPORATION H W R HWH CORPORATION 2096 MOSCOW ROAD MOSCOW, IOWA 52760 (800) 321-3494 / (563) 724-3396 HWH SPACEMAKER ROOM EXTENSION REPAIR MANUAL FEATURING: ONE - DUAL CYLINDER ROOM EXTENSION (WITH SYNCHRONIZING CYLINDER) OR ML23522/MI91.0021 07MAR01 ONE - FLAT FLOOR ROOM EXTENSION FOR WINNEBAGO MOTORIZED VEHICLES 310 OR 610 SERIES LEVELING SYSTEM INTERNET: http: //www.hwhcorp.com (WITH SYNCHRONIZING CYLINDER) ONE - FOUR CYLINDER ROOM EXTENSION AND (WITH SYNCHRONIZING CYLINDER) (ON I-80, EXIT 267 SOUTH)

· PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

  • Upload
    dolien

  • View
    216

  • Download
    3

Embed Size (px)

Citation preview

Page 1: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

HCORPORATION

HW R

HWH CORPORATION

2096 MOSCOW ROADMOSCOW, IOWA 52760

(800) 321-3494 / (563) 724-3396

HWH SPACEMAKER ROOM EXTENSION

REPAIR MANUAL

FEATURING:ONE - DUAL CYLINDER ROOM EXTENSION

(WITH SYNCHRONIZING CYLINDER)OR

ML23522/MI91.002107MAR01

ONE - FLAT FLOOR ROOM EXTENSION

FOR WINNEBAGO MOTORIZED VEHICLES310 OR 610 SERIES LEVELING SYSTEM

INTERNET: http: //www.hwhcorp.com

(WITH SYNCHRONIZING CYLINDER)

ONE - FOUR CYLINDER ROOM EXTENSIONAND

(WITH SYNCHRONIZING CYLINDER)

(ON I-80, EXIT 267 SOUTH)

Page 2: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

SECTION 1

MI91.110C05DEC00

SECTION2

FIGURES

SECTION

1

TROUBLE

SHOOTING

GUIDE

2 PART FOLDER

HOW TO USE MANUAL

This manual is written in two sections. Section 1 is the Trouble Shooting Guide. Section 2 is the figures. Begin diagnosis ofthe system with Section 1, the Trouble Shooting Guide. The Trouble Shooting Guide is broken into 3 columns, Problem,Solutions and Figures. Under Problems, find the symptom you have encountered. The testing and repair for that problem isin the Solution (center) column. Diagrams for a particular Problem and Solution are in the Figures (right hand) column. Thiscolumn will direct you to the proper figure in Section 2, Figures, for a more detailed view.

Before beginning your repair, it is IMPORTANT to read the CAUTIONS and NOTES AND CHECKS in the first section, TROUBLESHOOTING GUIDE. In many cases this will save time and mistakes when trouble shooting a system.

This Repair Manual is offered as a guide only. It is impossible to anticipate every problem or combination of problems. Forany problems encountered that are not addressed in this manual, contact HWH Corporation for assistance. (800-321-3494)

PROCEED WITH TROUBLE SHOOTING GUIDE

The room should be fully retracted before Trouble Shooting the system. If the room will not retract, use the manual retract pro-cedure on pages MP35.9490 and MP35.952D.

Make sure all room locks and the manual retract winch are not engaged before trouble shooting the system.

IMPORTANT: The four cylinder system incorporates pressure switches on the synchronizing cylinder to protect the system from damage due to high pressure. DO NOT operate the room with the pressure switches disconnected. If a pressure switch is tripped, the pump will not run when trying to operate the four cylinder room extension. A tripped pressure switch will not interfere with the operation of the front room.

Page 3: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

TROUBLE SHOOTING

MI91.112F21APR11

WARNING!

BLOCK FRAME AND TIRES SECURELY BEFORE CRAWLING UNDER VEHICLE. DO NOT USE THE LEVELINGJACKS OR AIR SUSPENSION TO SUPPORT VEHICLE WHILE UNDER VEHICLE OR CHANGING TIRES. VEHICLEMAY DROP AND OR MOVE FORWARD OR BACKWARD WITHOUT WARNING CAUSING INJURY OR DEATH.

WHEN ROUTING OR REROUTING HYDRAULIC HOSES AND WIRES, BE SURE THEY ARE NOT EXPOSED TO ENGINEEXHAUST OR ANY HIGH TEMPERATURE COMPONENTS OF THE VEHICLE.

NEVER PLACE HAND OR OTHER PARTS OF THE BODY NEAR HYDRAULIC LEAKS. OIL MAY CUT AND PENETRATE THE SKIN CAUSING INJURY OR DEATH.

SAFETY GLASSES ARE TO BE WORN TO PROTECT EYES FROM DIRT, METAL CHIPS, OIL LEAKS, ETC. FOLLOWALL OTHER SHOP SAFETY PRACTICES.

NOTES AND CHECKSRead and check before proceeding with Trouble Shooting Steps.

NOTE: HWH CORPORATION ASSUMES NO LIABILITYFOR DAMAGES OR INJURIES RESULTING FROM THEINSTALLATION OR REPAIR OF THIS PRODUCT.

1. If the room extension cannot be retracted, see Figures pagesMP35.9490 and MP35.952D for temporary measures. Makesure the manual retract valves are closed before trouble shooting.

4. Check that the oil reservoir is full with the room in the fullyretracted position.

5. Batteries should read 12.6 volts. Batteries must be in goodcondition with no weak cells. An alternator, converter or batterycharger will not supply enough power for the system to operateproperly. Check between the positive and negative posts of the

6. Proper ground of all components is critical. See the elec-trical circuit for specific grounds required. Faulty grounds,especially for the solenoid manifold or the pump assembly,may cause component damage and /or improper or erratic

This manual is intended for use by experienced mechanicswith knowledge of hydraulic and automotive electricalsystems. People with little or no experience with HWHRoom Extension systems should contact HWH technicalservice (800-321-3494) before beginning. Special attentionshould be given to all cautions, wiring, and hydraulic dia-

systems:JUMPER WIRES(UP TO 10 GAUGE)PRESSURE GAUGE(3500 PSI MIN.)MULTI-METER12 VOLT TEST LIGHT

PROCEED WITH THE TROUBLESHOOTING STEPS ON THE

FOLLOWING PAGE

grams.

Suggested tools for trouble shooting the HWH room extension

operation.

battery while the pump is running. This will check the batterycondition under load.

KEEP PEOPLE AND OBJECTS CLEAR OF THE ROOM EXTENSION WHEN IT IS BEING OPERATED. MAKESURE THERE IS AMPLE ROOM TO EXTEND THE ROOM FULLY.

2. The room extension can be operated any time the parkbrake is set. The ignition does not have to be in the ON orACC position.

3. Make sure the leveling system operates properly. Some problems encountered with the leveling system may create a problem with the room extension.

existing hose end, tighten the hose end to snug plus 1/4tighten the hose end 1/3 turn (2 FLATS). If tightening anmake the hose end snug (finger tight) on the fitting, thenTightening of hose ends: If tightening a new hose end,

turn (1 FLAT).

Page 4: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

TROUBLE SHOOTING

SOLUTION FIGURESPROBLEM

MI91.231C19DEC00

The following is a list of possible problems and solutions which might occur to room extensions. There will be only one powerunit / valve assembly to operate the room extension(s) and leveling system. There will be a room control switch for each roomextension.

If the leveling system does not operate properly, the room extension(s) may not operate properly.

Unless otherwise noted, the PROBLEM and SOLUTION is for either the FLAT FLOOR or DUAL CYLINDER room extensionswith a synchronizing cylinder or the SINGLE CYLINDER GUIDED room extension with any leveling system.

Part 1Neither roomwill extend orretract. The pump will notrun.

room controlswitch and theharness through the coach is supplied by Winnebago.

Only the PARKBRAKE needs tobe set for therooms to operate. TheIGNITION canbe OFF.

REFER TO MP85.322Q(310 LEVELING SYSTEM)

MP85.504M(610 LEVELING SYSTEM)

If the LEVELING SYSTEM is functioning properly, that should indicate that the PARK BRAKE is set, there is battery power to therelays on the pump and that the pump is functioning.

Check terminal B of the room extension pump relay for +12 power. If power is not present there is a problem with that connection.

Check terminal D for a ground. If there is no ground present, there is a problem with the connection at terminal D or a problem with the 9000 wire in the LEVELING SYSTEM MANIFOLD PUMP HARNESS.

If there is power on terminal B and a good ground for terminal D, check the 20 AMP fuse in the 6101 wire from terminal C. This supplies +12 battery power to the room control switches.

If the fuse is blown, replace the fuse. If the fuse blows immediately,the HWH 6101 wire or the Winnebago CCT wire is shorted to ground.If the fuse does not blow, retry either room. If the fuse does not blowcontinue testing the system. If the fuse blows, remove the 8602 wirefrom the pump relay, try the front room. If the fuse blows, the HWH8602 wire or the Winnebago DDA wire is shorted to ground. If the fuse does not blow, remove the 8603 wire from the pump relay. Trythe rear room. If the fuse blows, the HWH 8601 or 8603 wire, theinterrupt relay on the pump, or the Winnebago DDK wire is shorted to ground. If the fuse does not blow, reattach the 8602 and 8603wires to the pump relay and retry either room. If the fuse blows, replace the room extension pump relay.

If the 20 AMP fuse in the 6101 wire is not blown, check terminalsA and C for +12 power while pushing a room control switch. If thereis power on terminals A and C, there is a problem with the connectionat terminal C. Remember, if the pump runs for the leveling system,it will run for the room extensions.

If there is power on terminal A, but not C while pushing a room control switch, the room extension pump relay is bad and should bereplaced.

If there is no power on terminal A, find the connection for the HWHroom extension pump/manifold harness to the Winnebago roomcontrol harness. Check for +12 power on the 6101 wire (CCY) at theconnection. If power is not present, there is a problem between theconnection and the room pump relay on the 6101 wire. If there is +12 power on the 6101 (CCY) wire at the connection, check for power on the 8602 (DDA) wire, front room and the 8601 (DDK) wire,rear room while pushing the room control switches. If there is power on either wire, there is a problem on that wire between the connection and terminal A at the pump relay.

NOTE: The

PUMP CONTROL (DDK)

8601

CONNECTION

5000 (DR)ROOM 1 EXTEND -

SWITCHES BY OEM*ROOM CONTROL

AND INFORMATION REFER TO O.E.M.* FOR SPECIFIC WIRING DIAGRAMS

INTERRUPT HARNESSHWH POWER / WARNING /

(CCZ)

6 3

BATTERYSWITCHED +12

RETRACT

EXTEND(DR)

(DU)

5 24 17 8

ROOM 1

INTERRUPT

(DDA)CONTROLPUMP

6 3

JACK

5001 (BBM)EXTEND -ROOM 2

5101 (BBN)RETRACT -ROOM 2

DETAIL A

NO

4 15 2

7 8ROOM 2

RETRACT (BBN)EXTEND (BBM)

+12 BATTERY (CCY)

8602 (DDA)CONTROL -ROOM 1 PUMP

6101 (CCY)+12 BATTERY -

5100 (DU)RETRACT -ROOM 1

6810 (CCZ)BATTERY -SWITCHED +12

8601 (DDK)PUMP CONTROL -ROOM 2

(9 PIN FEMALE)SEE DETAIL A

INTERRUPTJACK

HARNESSCONTROLOEM ROOM

(610 LEVELING SYSTEM)

(310 LEVELING SYSTEM)

REFER TO MP85.321C

MP85.504F

DIAGRAM - ROOM EXTENSIONSEE ELECTRICAL CONNECTION

LEVELING SYSTEMDIAGRAM - HYDRAULICELECTRICAL CONNECTIONHARNESS - SEEPUMP/MANIFOLDLEVELING SYSTEM

AND ALL WIRE COLORS.NUMBER SUPERSEDES ANY

FROM THE CONTROL BOX

FROM THE SYNCHRONIZING CYLINDER

CYLINDER PRESSURE SWITCHESDIAGRAM - SYNCHRONIZINGSEE ELECTRICAL CONNECTIONPRESSURE SWITCH HARNESSSYNCHRONIZING CYLINDER

NOTE:

PIG

TA

ILT

O R

ELA

Y

7695

THE (4) DIGIT WIRE

PSW.SYNC. CYL.

(85)7695

NOTE: THERE MAY BE PLUGSBETWEEN THE HARNESS ANDTHE PUMP/MANIFOLD ASSEMBLY.

FROM RELAY A

FROM PARK BRAKE SWITCHHARNESS - GROUND SIGNALSYSTEM PUMP/MANIFOLDFROM THE LEVELING

+12 FOR PUMPMOTOR

TO RELAY B -

SUPPLY+12 BATTERY

SYSTEM

RELAY C

(BLUE) 9000D

C

B

(87A)

WITH THE MASTER ANDMANIFOLD ASSEMBLYMOUNTED ON THE PUMP/INTERRUPT RELAY ISTHE PRESSURE SWITCH

8601INT.JACK

RELAYSWITCH INTERRUPTEXTENSION PRESS.4 CYLINDER ROOM

INFORMATIONRELAY

85 86

30

87

87A

87

86

8587A

30

PUMP RELAYS

JACK

8601INT.

(BE

DR

OO

M)

CO

NT

RO

LP

UM

P R

ELA

Y

(30+86)8601

SEE GROUNDING

8602

68108603

6100A

FUSE

AMP20

INSTRUCTIONS

FUSE

AMP20

PUMP/MANIFOLD HARNESSROOM EXTENSION

8601

A

DIAGRAM - ROOM EXTENSIONSEE ELECTRICAL CONNECTION

AND ALL WIRE COLORS.NUMBER SUPERSEDES ANY

FROM THE SYNCHRONIZING CYLINDER

CYLINDER PRESSURE SWITCHESDIAGRAM - SYNCHRONIZINGSEE ELECTRICAL CONNECTIONPRESSURE SWITCH HARNESSSYNCHRONIZING CYLINDER

NOTE:

PIG

TA

ILT

O R

ELA

Y

7695

THE (4) DIGIT WIRE

PSW.SYNC. CYL.

(85)7695

FROM RELAY A

FROM PARK BRAKE SWITCHHARNESS - GROUND SIGNALSYSTEM PUMP/MANIFOLDFROM THE LEVELING

+12 FOR PUMPMOTOR

TO RELAY A

SUPPLY+12 BATTERY

SYSTEM

RELAY B

(BLUE) 9000D

C

B

(87A)

BETWEEN THE HARNESS ANDTHE PUMP/MANIFOLD ASSEMBLY.

WITH PUMP RELAYSMANIFOLD ASSEMBLYMOUNTED ON THE PUMP/INTERRUPT RELAY ISTHE PRESSURE SWITCH

NOTE: THERE MAY BE PLUGS

RELAYSWITCH INTERRUPTEXTENSION PRESS.4 CYLINDER ROOM

INFORMATIONRELAY

85 86

30

87

87A

87

86

8587A

30

(BE

DR

OO

M)

CO

NT

RO

LP

UM

P R

ELA

Y

(30+86)8601

SEE GROUNDING

8602

68108603

6101

FUSE

AMP20

INSTRUCTIONS

FUSE

AMP20

PUMP/MANIFOLD HARNESSROOM EXTENSION

8601

OR MP85.321J

OR MP85.504H

Page 5: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

TROUBLE SHOOTING

SOLUTION FIGURESPROBLEM

MI91.231E19DEC00

Part 1

REFER TO MP85.321C

(310 LEVELING SYSTEM)

OR MP85.504H(610 LEVELING SYSTEM)

ContinuedIf there is no power at the connection on the 8601 (DDK) wire or the8602 (DDA) wire while pushing a room control switch, remove theroom control switches. Check for +12 power at pin 2 of the switches. If power is not present, the problem is with the CCY wire or connections for the CCY wire. If there is power on pin 2 of the room control switch, check pin 1 while pushing the switch to EXTEND and pin 3 while pushing the switch to RETRACT. If power is not present on either pin, replace the switch. If power is present on pins 1 and 3 the problem is the Winnebago DDA wire (front room), the WinnebagoDDK wire (rear room), the Winnebago connection to the HWH harness, the HWH 8602 wire (front room), the HWH 8601 wire (rearroom), the pressure switch interrupt relay on the pump for the rear room or the 8603 wire from the interrupt relay to the room extensionpump relay.

Part 2The rear room operates fine but the frontroom does notwork. The pump does not run.

Remove the control switch for the front room. Check for +12 voltpower on pin 2 of the switch. If power is not present, the problem is with the Winnebago CCY wire.

Note: The CCY wire provides +12 power to operate the pump for allroom control switches.

If +12 power is present on pin 2, check pins 1 and 3 for power whilepushing the switch to EXTEND or RETRACT. If power is not presentreplace the switch. If power is present, the problem is the WinnebagoDDA wire, the HWH 8602 wire, connections for these wires or the connection for the 8602 wire at terminal A of the room extensionpump relay.

work. The pump

The front room

does not run.

room does notbut the rearoperates fine

Part 3 Important: During these tests DO NOT attempt to run the FOURCYLINDER room extension with the synchronizing cylinder pressureswitches unplugged.

The synchronizing cylinder for the four cylinder room extension isequipped with four pressure switches, one for each room cylinder.Early systems have a two wire pressure switch set at 4000 PSI. Later model systems have a one wire switch set at 5000 PSI. Theseswitches are normally open switches. They complete a ground circuit when closed under high pressure. The pressure switchesprotect the system from damage if one or more cylinders malfunctionwhile the room is operating. If a cylinder or corner of the room stopsmoving before the room is fully extended or retracted, pressurebetween the synchronizing cylinder and the rod end of the room cylinder can become extremely high.

If the front room is retracted, push the front room control switch toEXTEND briefly. If the front room is extended, push the front room control switch to RETRACT briefly. This should relieve pressure on the four cylinder synchronizing cylinder. Try the rear room. If the pump now runs, a pressure switch was closed.

There are two pressure reducing valves on the sync. cylinder. Therod end of the upper two room cylinders must be connected to thesevalves. Also the valves must be in the center two outlets of the sync.cylinder. If the valves need to be moved, make sure the upper cylinders are connected to the pressure reducing valves.

PUMP CONTROL (DDK)

8601

CONNECTION

5000 (DR)ROOM 1 EXTEND -

SWITCHES BY OEM*ROOM CONTROL

AND INFORMATION REFER TO O.E.M.* FOR SPECIFIC WIRING DIAGRAMS

INTERRUPT HARNESSHWH POWER / WARNING /

(CCZ)

6 3

BATTERYSWITCHED +12

RETRACT

EXTEND(DR)

(DU)

5 24 17 8

ROOM 1

INTERRUPT

(DDA)CONTROLPUMP

6 3

JACK

5001 (BBM)EXTEND -ROOM 2

5101 (BBN)RETRACT -ROOM 2

DETAIL A

NO

4 15 2

7 8ROOM 2

RETRACT (BBN)EXTEND (BBM)

+12 BATTERY (CCY)

HARNESSPUMP/MANIFOLDROOM EXTENSION

8602 (DDA)CONTROL -ROOM 1 PUMP

6101 (CCY)+12 BATTERY -

5100 (DU)RETRACT -ROOM 1

6810 (CCZ)BATTERY -SWITCHED +12

8601 (DDK)PUMP CONTROL -ROOM 2

(9 PIN FEMALE)SEE DETAIL A

INTERRUPTJACK

HARNESSCONTROLOEM ROOM

OR MP85.504H

REFER TO MP85.321C

(610 LEVELING SYSTEM)

(310 LEVELING SYSTEM)

MP85.504M

REFER TO MP85.322Q

OR

(610 LEVELING SYSTEM)

(310 LEVELING SYSTEM)

MP85.505G

REFER TO MP85.324C(310 LEVELING SYSTEM)

(610 LEVELING SYSTEM)

OR

*NOTE:SWITCHES WITH ONLY ONE WIRE. THIS GROUNDINGHARNESS MAY NOT BE PRESENT.

7695

PRESSURE SWITCH HARNESSSYNCHRONIZING CYLINDER

INSTRUCTIONSSEE GROUNDINGTO GROUND STUD

30

85

END OF THE SYNCHRONIZINGGO TO THE BOLT ON THETHESE RING TERMINALS

CYLINDER

CYLINDERSYNCHRONIZING

6230 6230

6230

7695

(85)7695

6230

NEWER SYSTEMS MAY HAVE PRESSURE

6230

7695

6230*

7695

DIAGRAM - ROOM EXTENSIONSEE ELECTRICAL CONNECTION

THE PUMP/MANIFOLD ASSEMBLY WITHRELAY - THE RELAY IS MOUNTED ONPRESSURE SWITCH INTERRUPT FOUR CYLINDER ROOM EXTENSION

PUMP RELAY

PUMP RELAYS

87A 87

86

OR MP85.321J

MP85.504F

OR MP85.321J

MP85.504F

Page 6: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

TROUBLE SHOOTING

SOLUTION FIGURESPROBLEM

MI91.231G19DEC00

Part 3

REFER TO MP85.324C(310 LEVELING SYSTEM)

ORMP85.505G

(610 LEVELING SYSTEM)

ContinuedIf the pressure reducing valves do not need to be moved or movingthe valves does not help, check room adjustments make sure a corner of the room is not dragging or catching on something.Retract the room to within two or three inches of being fully retracted.Loosen the room out adjustment nut several turns. Bump the room out and back in several inches. Tighten the room out adjustment nut.Check the height adjustment of the room. Refer to Winnebago for proper adjustment procedures.

If room adjustments are OK, check the sync. cylinder pressure switches. If two wire switches are used, replace all four switches with the 5000 PSI single wire switches. If the system has one wire switches or the problem continues after replacing the pressure switches, check the room extension hydraulic manifold. If the manifold has solenoid valves with a diameter of 1 1/2 inches changethe complete manifold to a manifold with the large solenoid valves.

If the system has the large solenoid valves or the problem continues.Check each sync. cylinder pressure switch to see which switch isclosed. (Check for continuity between the pressure switch wire connected to harness wire 7695 and ground.) Change the room cylinder for the switch that is closed. Refer to MP45.946A.

If changing the cylinder does not fix the problem, replace the sync.cylinder. Refer to MP45.9953.

NOTE:When replacing the four cylinder sync. cylinder on a Class Amotor home, a sync. cylinder with 5000 PSI pressure switches mustbe used.

If the pump will still not run with the pressure reduced on the sync. cylinder, it is an electrical problem in the system. If the frontroom is operating properly, the pump and pump relays are OK. Theproblem is in the wiring harness for the rear room.

Check each sync. cylinder pressure switch. Replace any switch thatis closed. (Shows continuity to ground.)

If the pressure switches are OK, check terminal 85, the 7695 wire, ofthe pressure switch interrupt relay for ground. If a ground is present,the 7695 wire is shorted to ground.

If there is no ground on terminal 85, check the 8603 wire at terminal Afor +12 volts while pushing the rear room control switch to EXTEND or RETRACT. If +12 volts is present, there may be a connectionproblem at terminal A.

If there is no power on the 8603 wire, check for +12 on terminal 87Aand the 8601 wire to terminal 86 of the pressure switch interrupt relaywhile pushing the room control switch. If power is present at terminal87A, the 8603 wire has a problem. If there is power to terminal 86

If there is no power on the 8601 wire at terminal 86, remove the rearroom control switch and check terminals 1 and 3 of the switch whilepushing the switch. If power is present, there is a problem on the Winnebago DDK wire, the HWH 8601 wire or connections betweenthese wires. Refer to Winnebago wiring diagrams.

If there is no power on terminals 1 and 3, check terminal 2 for +12.(Switch does not have to be pushed.) If power is present, the switchis bad. If power is not present there is a problem with the WinnebagoCCY wire. This wire also supplies power for the front room switch.

but not 87A, the interrupt relay is bad.

*NOTE:SWITCHES WITH ONLY ONE WIRE. THIS GROUNDINGHARNESS MAY NOT BE PRESENT.

7695

PRESSURE SWITCH HARNESSSYNCHRONIZING CYLINDER

INSTRUCTIONSSEE GROUNDINGTO GROUND STUD

30

85

END OF THE SYNCHRONIZINGGO TO THE BOLT ON THETHESE RING TERMINALS

CYLINDER

CYLINDERSYNCHRONIZING

6230 6230

6230

7695

(85)7695

6230

NEWER SYSTEMS MAY HAVE PRESSURE

6230

7695

6230*

7695

DIAGRAM - ROOM EXTENSIONSEE ELECTRICAL CONNECTION

THE PUMP/MANIFOLD ASSEMBLY WITHRELAY - THE RELAY IS MOUNTED ONPRESSURE SWITCH INTERRUPT FOUR CYLINDER ROOM EXTENSION

PUMP RELAY

PUMP RELAYS

87A 87

86

(310 LEVELING SYSTEM)REFER TO MP85.322Q

MP85.504M(610 LEVELING SYSTEM)

OR

A

DIAGRAM - ROOM EXTENSIONSEE ELECTRICAL CONNECTION

AND ALL WIRE COLORS.NUMBER SUPERSEDES ANY

FROM THE SYNCHRONIZING CYLINDER

CYLINDER PRESSURE SWITCHESDIAGRAM - SYNCHRONIZINGSEE ELECTRICAL CONNECTIONPRESSURE SWITCH HARNESSSYNCHRONIZING CYLINDER

NOTE:

PIG

TA

ILT

O R

ELA

Y

7695

THE (4) DIGIT WIRE

PSW.SYNC. CYL.

(85)7695

FROM RELAY A

FROM PARK BRAKE SWITCHHARNESS - GROUND SIGNALSYSTEM PUMP/MANIFOLDFROM THE LEVELING

+12 FOR PUMPMOTOR

TO RELAY A

SUPPLY+12 BATTERY

SYSTEM

RELAY B

(BLUE) 9000D

C

B

(87A)

BETWEEN THE HARNESS ANDTHE PUMP/MANIFOLD ASSEMBLY.

WITH PUMP RELAYSMANIFOLD ASSEMBLYMOUNTED ON THE PUMP/INTERRUPT RELAY ISTHE PRESSURE SWITCH

NOTE: THERE MAY BE PLUGS

RELAYSWITCH INTERRUPTEXTENSION PRESS.4 CYLINDER ROOM

INFORMATIONRELAY

85 86

30

87

87A

87

86

8587A

30

(BE

DR

OO

M)

CO

NT

RO

LP

UM

P R

ELA

Y

(30+86)8601

SEE GROUNDING

8602

68108603

6101

FUSE

AMP20

INSTRUCTIONS

FUSE

AMP20

PUMP/MANIFOLD HARNESSROOM EXTENSION

8601

Page 7: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

TROUBLE SHOOTING

SOLUTION FIGURESPROBLEM

MI91.231J19DEC00

Part 4The pump runswhen a room control switchis pushed to EXTEND butnot RETRACT ORwhen a switchis pushed toRETRACT butnot EXTEND.

Remove the switch that is not functioning properly. Check the connection of the DDA wires to pins 1 and 3 of the switch. If poweris present on both pins while pushing the switch to EXTEND andRETRACT, the problem is the DDA wire or DDA wire connections.If power is not present, replace the room control switch.

REFER TO MP85.321C

PUMP CONTROL (DDA)

RETRACT (BBN)EXTEND (BBM)+12 BATTERY (CCY)

CONNECTION

ROOM 1RETRACT - (DU)

BATTERY - (CCZ)

+12 BATTERY -

SWITCHED +12

6101 (CCY)

8601 (DDA)CONTROL -PUMP

SWITCHED +12 RETRACT (DU)

BATT. (CCZ)

DETAIL A

EXTEND - 5000

CONNECTIONNO

EXTEND -5001

ROOM 1 (DR)

ROOM 2 (BBM)

RETRACT -ROOM 2 (BBN)

5101

5100

6810

NO

ROOM CONTROL SWITCHES BY OEM*

ROOM 1

EXTEND (DR)

6 35 24 17 8

DDACCY

ROOM 2

CCYDDA

6 3

4 15 2

7 8

AND INFORMATION REFER TO O.E.M.*FOR SPECIFIC WIRING DIAGRAMS

(9 PIN FEMALE)SEE DETAIL A

HARNESSCONTROLOEM ROOM

Part 6The pump runsbut the room will not extendor retract. The pump seems to be deadheading.

There is no power to the room control switch to operate the solenoidvalves unless the pump is running. If the room will extend but notretract or will retract but not extend, there is power to the room control switch. The problem is between the room control switch andthe solenoid valves. Start troubleshooting at " There is power toterminal 5 of the room control switch."

Check terminal 5 of the room control switch for 12 volts while pushing the switch to extend or retract. With the pump motor runningthere should be +12 volts at terminal 5.

There is no power at terminal 5 of the room control switch.Check the 20 amp fuse in the 6810 wire at the room extensionpump relay. If the fuse is OK, the problem is the connection at terminal C of the relay, a problem with the HWH 6810 wire, a prob-lem with the connection of the HWH harness to the Winnebago har-ness or a problem with the Winnebago CCZ wire or connections inthe Winnebago harness. With the pump running, start at the pumprelays checking at each connection until the problem is isolated.

replace the fuse and push the room control switch toEXTEND. If the fuse blows again, the problem is the EXTEND valve,a short in the HWH 5000 (or 5001) wire, a short in the WinnebagoDR (or BBM) wire, the CCZ wire or the 6810 wire. If the fuse doesnot blow, push the switch to RETRACT. If the fuse blows, the problem is the retract valve, a short in the HWH 5100 (or 5101) wire, or a short in the Winnebago DU (or BBN) wire.

valve. If the problem stops, the problem is probably the room controlswitch. If the problem continues, replace the extend valve.

the extend valve is open. Unplug the extend

switch. If the problem continues, replace the retract valve.valve. If the problem stops, the problem is probably the room control

the retract valve is open. Unplug the retract

If the leveling system is working properly, continue.

room(s) and jacks fully retracted, check the fluid level in the tank. It release nuts (small valves) are closed (turn clockwise). With the Make sure all valve release "T" handles (large valves) and/or valve

or low pump pressure will cause a problem for the room extension(s).Check the operation of the leveling sysytem. A faulty shuttle valve

should be within 1 inch of the top.

If trying to RETRACT,

If trying to EXTEND,

pressure.does not build pump runs butretract. The extend or A room will notPart 5

If the room will neitherEXTEND or RETRACT, continue with the next paragraph.

If thefuse is blown,

(310 LEVELING SYSTEM)MP85.504F

(610 LEVELING SYSTEM)

6245

NOTE: THERE MAY BE PLUGS

5101

SOLENOID VALVEROOM 1 RETRACT

SOLENOID VALVEROOM 2 RETRACT

SOLENOID VALVEROOM 2 EXTEND

VALVE RELEASE"T" HANDLE

500051005001

RELAY WIRINGSEE PUMP

DIAGRAM

6246 62456246

VIEW FROMREAR OF PUMP

AB

B A

2R

2E

NOTE:

B A

AB

1R

1E

MANIFOLDSYSTEMLEVELING

HARNESSPUMP/MANIFOLDROOM EXTENSION

ROOM EXTENSION

INSTRUCTIONS

ROOM 1 - EXTENDSOLENOID VALVE

SEE POWER UNITHARNESS GROUNDING

HYDRAULIC MANIFOLD

VIEW FROM PUMP ENDBETWEEN THE HARNESS ANDTHE PUMP/MANIFOLD ASSEMBLY.

SYNC. CYL.PSW.

SEE ELECTRICAL CONNECTION

CYLINDER PRESSURE SWITCHES

(610 LEVELING SYSTEM)MP85.504M

REFER TO MP85.322Q(310 LEVELING SYSTEM)

PRESSURE SWITCH HARNESS

DIAGRAM - SYNCHRONIZING

+12 BATTERYSUPPLY

TO RELAY A

MOTOR+12 FOR PUMP

FROM THE LEVELINGSYSTEM PUMP/MANIFOLDHARNESS - GROUND SIGNALFROM PARK BRAKE SWITCH

FROM RELAY A

SYNCHRONIZING CYLINDER

TO

RE

LAY

7695

PIG

TA

IL

(BLUE) 9000

RELAY B

C

D

THE PRESSURE SWITCHINTERRUPT RELAY ISMOUNTED ON THE PUMP/MANIFOLD ASSEMBLYWITH PUMP RELAYS85 86

RELAYINFORMATION

3087

87A

PUMP/MANIFOLD HARNESS

FUSE

INSTRUCTIONS

FUSE

SEE GROUNDING

4 CYLINDER ROOMEXTENSION PRESS.SWITCH INTERRUPT

87A85

87

7695(85)

8603(87A)

RELAY

3086

6810

20AMP

SEE ELECTRICAL CONNECTIONDIAGRAM - ROOM EXTENSION

B

A 6101

SYSTEM

8602

20 AMP

ROOM EXTENSION

PU

MP

RE

LAY

(BE

DR

OO

M)

8601(30+86)

CO

NT

RO

L

8601

OR MP85.321J

OR MP85.504H

OR MP85.504HMP85.504F

OR MP85.321JREFER TO MP85.321C

(610 LEVELING SYSTEM)

(310 LEVELING SYSTEM)

Page 8: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

TROUBLE SHOOTING

SOLUTION FIGURESPROBLEM

MI91.231M19DEC00

Part 6Continued

connections for the solenoid valves or the solenoid valve itself.problem is the room control switch, the harness wires, the groundThere is power to terminal 5 of the room control switch.

ably a short in the Winnebago CCZ wire on the HWH 6810 wire.6810 wire blows when either room is operated the problem is prob-If the coach is equipped with two rooms and the 20 amp fuse in the

The

If the room will not retract, check terminal 6 of the room control switch while pushing the switch to RETRACT. If +12 volts is not present, replace the switch. If +12 volts is present, unplug the retractsolenoid valve and check for +12 between the A&B pins of the harness plug while pushing the switch to RETRACT. If +12 is present, replace the retract solenoid valve. If +12 is not present,check between pin B of the harness plug and a good frame groundwhile pushing the switch to RETRACT. If +12 is present, the problemis the ground wire or pin A for the retract solenoid valve. If +12 is notpresent, the problem is the HWH 5100 (or 5101) wire, the Winnebago DU (or BBN) wire or harness connections between the room switchand the retract valve.

Part 7The room moves irratic-ally from sideto side (walking/racking) as it extends or retracts.

The room extension mechanisms are designed to allow the room toextend and retract fully at both ends of the room. This allows the room to maintain a proper seal when extended or retracted. Somemovement of the room is allowable. Excessive racking is usuallycaused by the room binding on some obstruction. Check fore andaft adjustments of the room. The room may be binding on carpets,side walls ceilings or room seals. Improper height adjustments cancause the room mechanisms to bind. Awnings can cause the room to rack excessively. Air in the system can cause racking, especially after repairs. Make sure room extension tubes or cylinders are not covered with grease, paint or undercoating.

connections between the room switch and the EXTEND valve.5000 (or 5001) wire, the Winnebago DR (or BBM) wire or harnessEXTEND valve. If +12 is not present, the problem is the HWHIf +12 is present, the problem is the ground wire or pin A for thethe plug to a good frame ground, while pushing the switch to extend.the extend solenoid valve. If +12 is not present, check from pin B inplug, while pushing the switch to extend. If +12 is present, replacevalve and check for +12 volts between the A&B pins of the harnessreplace the switch. If +12 volts is present, unplug the extend solenoidswitch while pushing the switch to extend. If +12 volts is not present,

check terminal 4 of the room controlIf the room will not extend,

TEE

REPLACEMENT OR BOTH B1 LINES MUST BE REPLACED WITH 3/16" HIGH PRESSURE HOSE.SOME SYSTEMS MAY HAVE 1/8" HIGH PRESSURE B1 LINES. 1/8" HOSE MUST BE USED FOR

CYLINDER MUST BE THE SAME LENGTH AND DIAMETER. THE B1 LINES MUST BE HIGH PRESSURE HOSE.THE LINES (B1) BETWEEN THE ROD END OF THE HYDRAULIC CYLINDERS AND THE SYNCHRONIZING

THE LINES (A1) BETWEEN THE CAP END OF THE HYDRAULIC CYLINDERS AND THE TEE

CAP END

CAP END

HOSE CONNECTION AT REAR OF

MUST BE THE SAME LENGTH AND DIAMETER. IMPORTANT:

NOTE:

ROOM EXTENSION TUBE

VIEW 1

HYDRAULIC CYLINDER

SYNCHRONIZING CYLINDER.WITH DUAL ROOM CYLINDERS ANDTHE SAME FOR EACH ROOM EXTENSION

THESE CONNECTIONS ARE

DUAL CYLINDER ROOM EXTENSION

3/16" HIGH PRESSURE HOSE (B1)

HYDRAULIC CYLINDER

ROD END

ROD END

NOTE:

(A1)

STEEL TUBE

(A1)

PRESSURE HOSE (B1)3/16" HIGH

STEEL TUBE

1/4" HOSE CONNECTION

HOSE CONNECTIONHIGH PRESSURE

CAP END

ROD END 3/16"

SY

NC

HR

ON

IZIN

G C

YLIN

DE

R

VIEW 1

CONNECTION - BROD ENDCONNECTION - ACAP END

REFER TO MP65.302K

(610 LEVELING SYSTEM)MP85.504M

REFER TO MP85.322Q(310 LEVELING SYSTEM)

SEE ELECTRICAL CONNECTION

CYLINDER PRESSURE SWITCHES

PRESSURE SWITCH HARNESS

PU

MP

RE

LAY

CO

NT

RO

L(B

ED

RO

OM

)

8630

INFORMATION

PSW.SYNC. CYL.

30

85 86

87

87A

RELAY

8787A

85

THE PRESSURE SWITCHINTERRUPT RELAY ISMOUNTED ON THE PUMP/MANIFOLD ASSEMBLYWITH PUMP RELAYS

(30+86)8601

8602

RELAY

EXTENSION PRESS.SWITCH INTERRUPT

4 CYLINDER ROOM

PUMP/MANIFOLD HARNESS

SEE ELECTRICAL CONNECTIONDIAGRAM - ROOM EXTENSION

7695(85)

8603(87A)

B

SYSTEM

A 6101

6810

AMP

FUSE20

SEE GROUNDINGINSTRUCTIONS

FUSE

AMP20

8601

ROOM EXTENSION

DIAGRAM - SYNCHRONIZING

SYNCHRONIZING CYLINDER

7695

FROM PARK BRAKE SWITCH

+12 FOR PUMPMOTOR

PIG

TA

ILT

O R

ELA

Y

TO RELAY A

FROM THE LEVELINGSYSTEM PUMP/MANIFOLDHARNESS - GROUND SIGNAL

+12 BATTERYFROM RELAY A

SUPPLY

(BLUE) 9000

RELAY B

C

D

(610 LEVELING SYSTEM)

MP85.504F

OR MP85.321J(310 LEVELING SYSTEM)

PUMP CONTROL (DDK)

6245

8601

CONNECTION

5000 (DR)ROOM 1 EXTEND -

NOTE: THERE MAY BE PLUGS

5101

SOLENOID VALVEROOM 1 RETRACT

SOLENOID VALVEROOM 2 RETRACT

SOLENOID VALVEROOM 2 EXTEND

VALVE RELEASE

CONNECTORS

"T" HANDLE

500051005001

RELAY WIRINGSEE PUMP

DIAGRAM

6246 62456246

VIEW FROMREAR OF PUMP

AB

B A

2R

2E

NOTE:

B A

AB

1R

1E

SWITCHES BY OEM*ROOM CONTROL

A & B ON PACKARDWIRE COLORS TODO NOT REVERSE

AND INFORMATION REFER TO O.E.M.* FOR SPECIFIC WIRING DIAGRAMS

INTERRUPT HARNESSHWH POWER / WARNING /

(CCZ)

6 3

BATTERYSWITCHED +12

RETRACT

EXTEND(DR)

(DU)

5 24 17 8

ROOM 1

MANIFOLD

INTERRUPT

(DDA)

SYSTEMLEVELING

CONTROLPUMP

6 3

JACK

5001 (BBM)EXTEND -ROOM 2

5101 (BBN)RETRACT -ROOM 2

DETAIL A

NO

4 15 2

7 8ROOM 2

RETRACT (BBN)EXTEND (BBM)

+12 BATTERY (CCY)

HARNESSPUMP/MANIFOLDROOM EXTENSION

ROOM EXTENSION

INSTRUCTIONS

ROOM 1 - EXTENDSOLENOID VALVE

SEE POWER UNITHARNESS GROUNDING

HYDRAULIC MANIFOLD

8602 (DDA)CONTROL -ROOM 1 PUMP

6101 (CCY)+12 BATTERY -

5100 (DU)RETRACT -ROOM 1

6810 (CCZ)BATTERY -SWITCHED +12

8601 (DDK)PUMP CONTROL -ROOM 2

(9 PIN FEMALE)SEE DETAIL A

INTERRUPTJACK

HARNESSCONTROLOEM ROOM

VIEW FROM PUMP ENDBETWEEN THE HARNESS ANDTHE PUMP/MANIFOLD ASSEMBLY.

REFER TO MP85.321C

OR MP85.504H

Page 9: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

TROUBLE SHOOTING

SOLUTION FIGURESPROBLEM

MI91.231P19DEC00

Part 7Continued

REPLACEMENT OR BOTH B1 LINES MUST BE REPLACED WITH 3/16" HIGH PRESSURE HOSE.SOME SYSTEMS MAY HAVE 1/8" HIGH PRESSURE B1 LINES. 1/8" HOSE MUST BE USED FOR

CYLINDER MUST BE THE SAME LENGTH AND DIAMETER. THE B1 LINES MUST BE HIGH PRESSURE HOSE.THE LINES (B1) BETWEEN THE ROD END OF THE HYDRAULIC CYLINDERS AND THE SYNCHRONIZING

THE LINES (A1) BETWEEN THE CAP END OF THE HYDRAULIC CYLINDERS AND THE TEE

HOSE CONNECTION AT REAR OF

MUST BE THE SAME LENGTH AND DIAMETER. IMPORTANT:

NOTE:

ROOM EXTENSION TUBE

VIEW 1

1/4" HOSE CONNECTION

HOSE CONNECTIONHIGH PRESSURE

CAP END

ROD END 3/16"

DUAL CYLINDER ROOMS WITH SYNCHRONIZING CYLINDER.Improper hose lengths can cause racking. Hoses between the sync.cylinder and the rod end of the room cylinders must be the same length and diameter high pressure hose. Hoses from the cap end ofthe room cylinders and where they tee together must be the same length and diameter. They do not have to be high pressure hose.Cap end and rod end hoses do not have to be the same.

If the room is not binding anywhere and the hose lengths are OK, replace the synchronizing cylinder.

REFER TO MP45.9953

Part 8The ends of theroom do not move at anequal distancefrom the vehicle.

The system is designed to run unsynchronized for approximately 1 inch at the end of the travel of the room when extending or retract-ing. This allows the room to seal properly when extended or retractedat the front and rear of the room. As long as the room does not rackexcessively and seals properly front and rear when fully extended orretracted, there is no problem and no adjustments that will change this. If the room seems to catching, check up and down adjustmentsalso fore and aft adjustments.

REFER TO MP65.302K

The following deals with either single or dual cylinder room extensions.There are three possibilities:

A. An extend solenoid valve is leaking.B. A room extension cylinder has an internal leak.C. The manifold check valve is leaking.

Retract the room completely. Remove the hydraulic line for the capend of the cylinder at the manifold. Hold the line with the hose endin an upright position. Press the rocker switch for that room to theRETRACT position.

If fluid flows from the manifold fitting, the extend solenoid valve needsto be changed.

REFER TO MP65.390F

SINGLE CYLINDER ROOM EXTENSION

HYDRAULIC

PRESSURE ON IT)WILL ALWAYS HAVECYLINDER (THIS LINELINE TO ROD END OF

CAP ENDLINE TO

Part 9The room creepsout after being re-tracted.

NOTE : If the room creeps out 1 or 2 inches or less the problem ismost likely the check valve.

OF CYLIN-DER

CYLINDER

OR MP65.390H

REFER TO MP65.390FOR

REFER TO MP65.390H

FOUR CYLINDER WITH SYNCHRONIZING CYLINDER. Improperhose lengths can cause racking. Hoses between the upper andlower cylinders are different. Refer to MP65.390Q for correct hoseinformation.

REFER TO MP65.390Q

IMPORTANT: THE TWO LINES BETWEEN THE CAP END OF THE LOWER CYLINDERS AND THE TEE ASSEMBLYMUST BE THE SAME LENGTH AND DIAMETER.

THE TWO LINES BETWEEN THE ROD END OF THE LOWER CYLINDERS AND THE SYNCHRONIZING CYLINDERMUST BE HIGH PRESSURE HOSE THAT IS THE SAME LENGTH AND DIAMETER.

THE TWO LINES BETWEEN THE CAP END OF THE UPPER CYLINDERS AND THE TEE ASSEMBLY MUST BE THE SAME LENGTH AND DIAMETER.

THE TWO LINES BETWEEN THE ROD END OF THE UPPER CYLINDERS AND THE SYNCHRONIZING CYLINDERMUST BE HIGH PRESSURE HOSE THAT IS THE SAME LENGTH AND DIAMETER.

!NOTE: THE PRESSURE REDUCING VALVES MAY BE IN A DIFFERENTPOSITION ON THE SYNCHRONIZINGCYLINDER. THEY WILL ALWAYS CONNECT TO THE ROD END OF THEUPPER CYLINDERS.

Page 10: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

TROUBLE SHOOTING

SOLUTION FIGURESPROBLEM

MI91.231R19DEC00

Part 9Continued

Replace the retract solenoid valve for that room extension. This isthe only possibility that would cause this problem.

If no fluid flows from either the hose end or the manifold fittings, in-spect the manifold check valve. There is a spring below the cap.DO NOT lose the spring. Check for cuts on the poppet o-ring. Checkthe poppet and cap for burrs. The poppet should easily slide in the

To replace a four cylinder room extension cylinder, see MP45.946A.

DETAIL "A"

CAP

POPPET

O-RINGSPRING

To replace a dual cylinder room extension cylinder, see MP45.9435.

REFER TO MP65.390F

Part 10The room creepsback in after be-ing extended.

cap. If the check valve is OK, the problem is most likely the solenoidvalve. Support the cap end hose with the hose end up. Allow the

If fluid flows from the hose end, the room extension cylinder shouldbe replaced.

OR MP65.390H

To replace a "FLAT FLOOR" room ext. cylinder, see MP45.947A

system to sit for several hours. Check and see if fluid is seeping fromhose or the manifold fitting.

Part 11

Part 12

The room doesnot seal tightlywhen fullyextended orretracted.

"FLAT FLOOR"ONLY. The roomwill not drop tothe flat positionas it extends.

For four cylinder room extensions see MP45.946A.

For dual cylinder room extensions see MP45.9436.

For "FLAT FLOOR" dual cylinder room extensions see MP45.947D

The problem is probably the "FLIPPERS" in the "FLAT FLOOR"mechanism. This is a complicated repair. Contact HWH CustomerService before attempting to make this repair.

REFER TO MP65.390FOR

REFER TO MP65.390H

Page 11: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

MP35.949002FEB12

MANUAL ROOM RETRACT PROCEDURE

1. Retract jacks following the LEVELING SYSTEM RETRACTPROCEDURE.

2. Locate the HYDRAULIC PUMP/MANIFOLD unit.

3. Open the SOLENOID VALVES by turning the "T" HANDLEScounterclockwise.

will become more difficult to turn as an internal spring is compressed. Be sure to open both valves completely (about six turns of the "T" HANDLE).

are opened and internal pressure is released.

SOLENOID VALVES"T"HANDLES

(USE ONLY WHEN THE ROOM WILL NOT RETRACT WITH THE ROOM CONTROL SWITCH)

WINCH

WINCH STRAP

WINCH HANDLE

RATCHET LEVER

HOOK

MANUAL RETRACT WINCH

4. Locate the MANUAL RETRACT WINCH and connect it tothe room according to the vehicle manufacturer’s instructions.To extend the WINCH STRAP firmly grasp WINCH HANDLE,place RATCHET LEVER in its OFF position, and slowly rotatethe WINCH HANDLE counterclockwise, keeping a firm grip onthe handle. When enough WINCH STRAP is extended, place theRATCHET LEVER in its ON position and slowly rotate the WINCHHANDLE clockwise until the RATCHET LEVER locks.

5. Slowly winch the room in by turning the WINCH HANDLEclockwise. The RATCHET LEVER should produce a loud, sharp,clicking noise.

hydraulic fluid and make winching more difficult.

WARNING:

ON

OFF

HYDRAULIC PUMP/MANIFOLD

NOTE : The room may move slightly as the SOLENOID VALVES

NOTE : NOTE : Winching the room in quickly will raise pressure in the

NOTE : The "T" HANDLE may turn easily at first but

6. When the room is fully retracted, engage the room lockingdevices. Leave the retract winch in place.

WARNING: THE ROOM EXTENSION SOLENOID VALVE"T" HANDLES MUST BE IN THE OPEN POSITION WHEN THEMANUAL RETRACT WINCH IS ENGAGED.

7. The system should be repaired before using again.

WARNING: THE MANUAL RETRACT WINCH ISEQUIPPED FOR MANUALLY RETRACTING THE ROOMONLY. IT IS NOT TO BE USED FOR LIFTING OR ANY

When manually retracting the room, make sure thejacks are retracted before retracting the room.

OTHER APPLICATION. HIGH FORCES ARE CREATEDWHEN USING A WINCH, CREATING POTENTIAL SAFETY HAZARDS. FAILURE TO FOLLOW ALL CAUTIONS ANDINSTRUCTIONS MAY CAUSE FAILURE OF THE MANUALRETRACT WINCH OR CONNECTIONS RESULTING INDAMAGE OR PERSONAL INJURY. MAINTAIN FIRM GRIP ON THE WINCH HANDLE AT ALL TIMES. NEVER RELEASETHE HANDLE WHEN RATCHET LEVER IS IN THE OFFPOSITION AND THE WINCH IS LOADED. THE WINCHHANDLE COULD SPIN VIOLENTLY AND CAUSE PERSONALINJURY. CHECK THE WINCH AND STRAPS FOR DAMAGEOR WEAR, AND CHECK FOR PROPER RATCHET OPERATIONON EACH USE OF THE WINCH. DO NOT USE IF DAMAGED

OPERATE THE MANUAL RETRACT WINCHBY HAND POWER ONLY. IF THE WINCH CANNOT BECRANKED EASILY WITH ONE HAND IT IS PROBABLY OVER-LOADED. IF WINCHING BECOMES TOO DIFFICULT STOPAND CHECK FOR OBSTRUCTIONS OR RESTRICTIONS ONTHE ROOM AND ROOM EXTENSION MECHANISM.

(WITH SOLENOID VALVES WITH VALVE RELEASE "T" HANDLES)

failure prevents the room from being retracted using theCONTROL SWITCH. For normal retract sequence see theROOM SLIDE RETRACT PROCEDURES.vehicle manufacturer for storage location of theretract device and information for connecting thedevice to the room.

IMPORTANT: If the vehicle is not equipped with a winch,DO NOT use other pulling devices to retract the room.Follow steps 2 and 3 and try pushing the room in.Contact the vehicle manufacturer or HWH CustomerService at 1-800-321-3494 or 563-724-3396 for assistance.

The room can be retracted manually if a hydraulic or electricOVERVIEW

Refer to the

OR WORN.

Page 12: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

MP35.952D01MAY02

MANUAL ROOM AND GENERATOR SLIDE RETRACT PROCEDURE

OVERVIEW

1. Retract jacks following the LEVELING SYSTEM RETRACT PROCEDURE.

2. Locate the HYDRAULIC PUMP/MANIFOLD unit.

VALVES are opened and internal pressure is released.

WINCH

WINCH STRAP

WINCH HANDLE

RATCHET LEVER

HOOK

MANUAL RETRACT WINCH

5. Slowly winch the room in by turning the WINCH HANDLEclockwise. The RATCHET LEVER should produce a loud, sharp,clicking noise.

in the hydraulic fluid and make winching more difficult.

CAUTION:

ON

OFF

HYDRAULIC PUMP/MANIFOLD

NOTE: The room may move slightly as the SOLENOID

NOTE :

NOTE: Winching the room in quickly will raise pressure

IMPORTANT:

6. When the room is fully retracted, engage the room lockingdevices. Leave the retract winch engaged and the solenoid

CAUTION: THE ROOM EXTENSION SOLENOID VALVE RELEASE NUTS MUST BE IN THE OPEN POSITION WHEN THE MANUAL RETRACT WINCH IS

7. The system should be repaired before using again.

CAUTION: THE MANUAL RETRACT WINCH IS

OPERATE THE MANUAL RETRACT WINCH BY HAND POWER ONLY. IF THE WINCH CANNOT BE CRANKED EASILY WITH ONE HAND IT IS PROBABLY OVERLOADED. IF WINCHING BECOMES TOO DIFFICULT STOP AND CHECK FOR OBSTRUCTIONS OR RESTRICTIONS ON THE ROOM AND ROOM

LEVELING SYSTEM MANIFOLD NOT SHOWN

SOLENOID VALVES

VALVE RELEASENUT

NUT

VALVE RELEASE

3. Open the Solenoid Valves by slowly turning the valve release nuts counter clockwise using the 1/4" nut driver

Only open the valves enough to retractNOTE: After repairs are made, when closing the VALVE RELEASE NUTS, do

When manually retracting the room, make surethe jacks are retracted before retracting the room.

EQUIPPED FOR MANUALLY RETRACTING THE ROOM ONLY. IT IS NOT TO BE USED FOR LIFTING OR ANY OTHER APPLICATION. HIGH FORCES ARE CREATED WHEN USING A WINCH, CREATING POTENTIAL SAFETY HAZARDS. FAILURE TO FOLLOW ALL CAUTIONS AND INSTRUCTIONS MAY CAUSE FAILURE OF THE MANUAL RETRACT WINCH OR CONNECTIONS RESULTING IN DAMAGE OR PERSONAL INJURY. MAINTAIN FIRM GRIP ON THE WINCH HANDLE AT ALL TIMES. NEVER RELEASE THE HANDLE WHEN RATCHET LEVER IS IN THE OFF POSITION AND THE WINCH IS LOADED. THE WINCH HANDLE COULD SPIN VIOLENTLY AND CAUSE PERSONAL INJURY. CHECK THE WINCH AND STRAPS FOR DAMAGE OR WEAR, AND CHECK FOR PROPER RATCHET OPERATION ON EACH USE OF THE WINCH. DO NOT USE IF DAMAGED OR WORN.

supplied.

the room. DO NOT turn the release nuts more than4 and 1/2 turns. Turning the nuts more could damagethe valves.

with the Operators Manual. As of APRIL 2002 the NOTE: Prior to APRIL 2002 a 1/4" Nut Driver was sent

Cap. See the back page of this manual for further info.1/4" Nut Driver has been incorporated into the Breather

4. Locate the MANUAL RETRACT WINCH and connect it to the room according to the vehicle manufacturer’s instructions. To extend the WINCH STRAP firmly grasp WINCH HANDLE, place RATCHET LEVER in its OFF position, and slowly rotate the WINCH HANDLE counter clockwise, keeping a firm grip on the handle. When enough WINCH STRAP is extended, place the RATCHET LEVER in its ON position and slowly rotate the WINCH HANDLE clockwise until the RATCHET LEVER locks.

EXTENSION MECHANISM.

valves open.

ENGAGED.

(WITH SOLENOID VALVES WITH VALVE RELEASE NUTS)(USE ONLY WHEN THE ROOM WILL NOT RETRACT WITH THE ROOM CONTROL SWITCH)

not over tighten the nuts.

IMPORTANT: If the vehicle is not equipped with a winch,DO NOT use other pulling devices to retract the room.Follow steps 2 and 3 and try pushing the room in.Contact the vehicle manufacturer or HWH CustomerService at 1-800-321-3494 or 563-724-3396 for assistance.

The room can be retracted manually if a hydraulic or electric failure prevents the room from being retracted using the CONTROL SWITCH. For normal retract sequence see the ROOM SLIDE RETRACT PROCEDURES. Refer to the vehicle manufacturer for storage location of the winch and information for connecting the winch to the room.

Page 13: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

ML16463/MP45.943527NOV01

2. Loosen the extend valve "T" Handle/Valve release nut.

3. Loosen the retract valve "T" Handle/Valve release nut.

NOTE: Do not remove the caps from the new cylinder

12. Remove Hose A from the room extension manifold. Usea cap from the new cylinder to cap the fitting in the manifold.Direct Hose A into the fluid reservoir.

13. Close the extend & retract valve "T" handles/Valve release nuts.

14. Push and hold the room control switch to "EXTEND" untilthe new cylinder is fully extended plus five seconds.

IMPORTANT: DO NOT PULL THE CYLINDER ROD OUT OF THE NEW CYLINDER. INSTALL THE NEW CYLINDERWITH THE ROD RETRACTED AS IT WAS SHIPPED.

NOTE:

CAUTION:DO NOT TRY TO LINE THE ROOM

THE ROD IS EXTENDING.CYLINDER ROD UP WITH THE MOUNTING HOLE WHILE

15. Reattach Hose A to the room extension manifold.

22. Check all hose connections and mounting nuts and boltsfor tightness and leaks.

hose connections until you are ready to reattach the hoses. Save the caps.

11. Attach the hoses to the cylinder. Do not over tighten thehose ends. See MP45.9436 for tightening of hoses.

8. Remove the cylinder cap end mounting plate from the oldcylinder and attach it to the new cylinder.

10. Install the new cylinder in the room extension tube. DONOT install the two cylinder cap end mounting plate nuts andwashers.

The cap end of the cylinder will push the cylinder capend mounting plate off the room extension tube. This is ok.

17. Slide the cylinder rod thru the rod mounting plate holeon the inner sliding tube. Install the nuts and lock washers onthe cylinder cap end mounting plate. Turn the cylinder rod inneradjusting nut into place and install the cylinder rod outer adjusting nut. Make the nut snug only, as a final adjustment will

6. Remove and cap the hoses at the end of the cylinder that is to be replaced.

IMPORTANT: Steps 4 and 5 must be done to protect the

7. Remove the cylinder that is to be replaced from the room extension tube.

9. Install the inner out stop adjusting nut and lock washer completely onto the threaded rod of the new cylinder.

have to be made. Do this for the front and rear cylinders.

ROOM EXTENSION CYLINDER REPLACEMENTDUAL CYLINDER ROOM EXTENSION(WITH SYNCHRONIZING CYLINDER)

READINSTRUCTIONS

PROCEEDINGBEFORETHOROUGHLYSTOP

IMPORTANT: Do not reverse direction of the room untilthe room is fully extended or retracted.

IMPORTANT: The following instructions must be followed or air lock of the synchronizing cylinder and unsynchronized operation of the room cylinders may result causing damage to the room. Please read the instructions before replacing the cylinder. DO NOT reverse direction of the room unless the room is fully extended or retracted.

1. Extend the room fully. There is an access hole on the inner sliding tube to access the cylinder rod mounting nuts. If the room cannot be fully extended the inner sliding tube access hole must be extended far enough to access the cylinder rod mounting nuts.

room from being damaged while bleeding air from and synchronizing the the room cylinders.

5. Remove the cylinder rod outer out stop adjusting nut for both the front and rear room cylinders.

IMPORTANT: BEFORE INSTALLING THE NEW CYLINDER, CLEAN ALL EXCESS OIL FROM THE ROOM EXTENSION TUBE. SWAB THE TUBE THOROUGHLY WITH A MILD SOLVENT AND RAGS. EXCESS OIL LEFT IN THE TUBE MAY LEAK OUT GIVING THE APPEARANCE OF A LEAKY CYLINDER OR HOSE CONNECTION.

16. Push and hold the room control switch to "RETRACT" until both cylinders are fully retracted, plus 5 seconds. Extend and retract the cylinders at least twice or until they are running fully synchronized. DO NOT reconnect the cylinders until they are running fully synchronized.

18. Push the room control switch to retract and hold until the room is fully retracted plus 5 seconds. Watch for excessive racking of the room. Some racking can occur do to air in the system. If the room starts to bind up, release the room control switch immediately. If the room does not bind up, proceed to Step 20. If the room is bound up, go to Step 19.

19. If the room is bound up, repeat Steps 2, 3, 4 and 5. Manually push the room out to its full extension. Now repeat Steps 13, 16, 17 and 18. If the room will still not run properly, contact HWH CORPORATION Customer Service at (800)321-3494 or at (563)724-3396.

21. With the room fully extended, check seals for proper compression. If the seal is not compressed or needs more compression, loosen the cylinder rod outer adjusting nut and tighten the cylinder rod inner adjusting nut. If the seal is compressed too much, loosen the cylinder rod inner adjusting nut and tighten the cylinder rod outer adjusting nut.

4. Remove the two nuts and washers from the cylinder cap end mounting plate for both the front and rear room cylinders.

20. Extend the room fully again. Do not reverse direction until the room is fully extended. Repeat retracting and extending the room several times being careful not to reverse directions until the room is fully extended or retracted.

Page 14: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

CYLINDER REPLACEMENTDUAL CYLINDER ROOM EXTENSIONWITH SYNCHRONIZING CYLINDER

VIEW A VIEW BIN STOPADJUSTMENT

OUTER ROOMROOM EXTENSIONTUBEOUT STOP

ADJUSTMENT

INNER ROOMEXTENSIONTUBE

HOSE A

THIS LINEGOES TOTHE TANK

CAP THISFITTING

EXTEND SOLENOIDVALVE

RETRACT SOLENOIDVALVE

VALVE RELEASE"T" HANDLES

NOTE: ROD AND CAP END HOSE CONNECTIONSWILL BE THE SAME FOR MULTIPLE ROOMEXTENSIONS.

CYLINDER MOUNTINGPLATE NUT

ROD END 1/8"HIGH PRESSUREHOSE CONNECTION

CAP END

HOSECONNECTION

CYLINDERMOUNTING NUT

CYLINDERMOUNTINGPLATE NUT

CYLINDER MOUNTINGPLATE

VIEW B

OUTER OUT STOPADJUSTING NUT INNER OUT STOP

ADJUSTING NUT

VIEW A

ROOM EXTENSION MANIFOLD

ML16463/MP45.943630JAN01

3/16" HIGH PRESSURE HOSE

SY

NC

HR

ON

IZIN

G C

YLIN

DE

R

LOCK WASHERS(OLDER UNITS MAYNOT HAVE LOCK WASHERS

HOSE 4

3/16" HIGH PRESSURE HOSE

HOSE 1

HOSE 2

HOSE 3

IMPORTANT: HOSES 1 AND 2 BETWEEN THE CAP END OF THECYLINDERS AND THE PUMP MUST BE THE SAME LENGTH AND DIAMETER.

HOSES 3 AND 4 BETWEEN THE ROD END OF THE CYLINDERS AND THESYNCHRONIZING CYLINDER MUST BE THE SAME LENGTH HIGH PRESSUREHOSE. SOME EARLY SYSTEMS USED 1/8" HIGH PRESSURE HOSE. DO NOTMIX 1/8" HIGH PRESSURE AND 3/16 HIGH PRESSURE HOSE.

TIGHTENING AN EXISTING HOSE END, TIGHTEN THE HOSE ENDTHEN TIGHTEN THE HOSE END 1/3 TURN (2 FLATS). IFMAKE THE HOSE END SNUG (FINGER TIGHT) ON THE FITTING, TIGHTENING OF HOSE ENDS: IF TIGHTENING A NEW HOSE END,

TO SNUG PLUS 1/4 TURN (1FLAT).

Page 15: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

ML21058/MP45.946A27NOV01

CYLINDER REPLACEMENT/BLEEDING PROCEDUREFOUR CYLINDER ROOM EXTENSIONWITH SYNCHRONIZING CYLINDERWITH ROOM EXTENSION MANIFOLD

NOTE: Do not remove the caps from the new cylinder hoseconnections until you are ready to reattach the hoses. Savethe caps.

3. Loosen the retract valve "T" handle/Valve release nut.

IMPORTANT: Step 5 must be done to protect the room frombeing damaged while bleeding air from and synchronizing theroom cylinders.

7. Remove the three cylinder mounting bolts.

8. Remove the cylinder from the vehicle.

15. Reattach hose A to fitting A.

21. Check again for leaks and hose routings. Clean any oilspills. Reinstall the vehicle interior.

READINSTRUCTIONS

PROCEEDINGBEFORETHOROUGHLYSTOP

2. Loosen the extend valve "T" handle/Valve release nut.

12. Remove hose A from the manifold. Remove the breathercap and direct hose A into the tank. Cap fitting A with a steelcap from the replacement cylinder.

existing hose end, tighten the hose end to snug plus 1/4tighten the hose end 1/3 turn (2 FLATS). If tightening anmake the hose end snug (finger tight) on the fitting, thenTightening of hose ends: If tightening a new hose end,

turn (1 FLAT).

If a room cylinder is not being replaced but the room cylinders are not synchronized, follow Steps 1, 4, 5, and Steps 15 thru 18.

IMPORTANT: The following instructions must be followed or air lock of the synchronizing cylinder and unsynchronized operation of the room cylinders may result causing damage to the room. Please read the instructions before replacing the cylinder. DO NOT reverse direction of the room unless the room is fully extended or retracted.

1. Extend the room fully. Support the outer edge of the room so that the room cannot sag when the room cylinder rods are disconnected. If the room will not extend, disconnect the room cylinder rods from the room and manually pull the room out to it’s full extension and support the room.

4. Remove coach equipment and panels as necessary to gain access to all four room cylinders. Protect the coach interior from possible oil spillage.

5. Remove the outer out stop adjustment nut from each cylinder.

6. Remove and cap the hoses from the rod and cap end of the cylinder that is to be replaced. Cap the cylinder fittings.

IMPORTANT: DO NOT PULL THE CYLINDER ROD OUT OF THE NEW CYLINDER. INSTALL THE CYLINDER WITH THE ROD RETRACTED AS IT WAS SHIPPED.

10. Install the new cylinder and attach it to the vehicle with the three mounting bolts. Do not pull the rod out of the cylinder.

9. Install the inner out stop adjustment nut from the old cylinder onto the new cylinder rod as far as it will go.

11. Reattach the hoses to the correct fittings. Do not over tighten the fittings.

14. Push and hold the room control switch to "EXTEND" until the new cylinder is fully extended plus 3 to 5 seconds. Watch carefully that the cylinder does not extend too far.

16. Push and hold the room control switch to "RETRACT" until all four cylinders are fully retracted. The new cylinder may not retract until the other three cylinders are fully retracted.

17. Repeat extending and retracting the cylinders fully at least 3 more times or until the cylinders are completely synchronized. Do not go from "RETRACT" to "EXTEND" until the cylinders are fully retracted. Do not go from "EXTEND" to "RETRACT" until the cylinders are fully extended. Check that there are no leaks and that hose routings are ok.

18. Reattach all four cylinders to the room with the out stop adjustment nuts. Run the inner out stop adjustment nut on the new cylinder out to the room for the initial adjustment.

19. Retract the room watching carefully that the room does not bind up. If the room binds up, DO NOT try to extend the room. Remove the outer out stop adjustment nuts and manually push the room out and support it. Repeat Steps 16thru 18. If the room will still not work properly, call HWH CORPORATION Customer Service at (800)321-3494 or at (563)724-3396.

20. If the room works properly, extend and retract the room several times. Watch carefully that the room does not extend too far or bind up. Check that the room seals are properly compressed with the room extended. If the room needs to extend more, loosen the outer out stop adjustment nut and turn the inner adjustment nut out until the room is seated properly. Tighten the outer adjustment nut. If the room is extended too far, loosen the inner outstop nut and tighten the outer adjustment nut until the room is seated properly. Tighten the inner adjustment nut.

13. Close the extend and retract valve "T" handles/Valve release nuts.

Page 16: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

ML21058/MP45.946B160CT00

ROOM EXTENSION CYLINDER REPLACEMENT/BLEEDING PROCEDUREFOUR CYLINDER ROOM EXTENSIONWITH SYNCHRONIZING CYLINDER

WITH ROOM EXTENSION MANIFOLD

ROD END ROD END

CAP END

CAP END

UPPERCYLINDERS

OUTER OUTSTOP ADJUST-MENT NUT

INNER OUTSTOP ADJUST-MENT NUT

SYNCHRONIZING CYLINDERROD END CAP END

VIEW A

CYLINDERMOUNTINGBOLTS (3)

ROD ENDCAP END

CAP END

ROD END

VIEW ALOWERCYLINDERS

NOTE: ROD AND CAP END HOSE CONNECTIONSWILL BE THE SAME FOR MULTIPLE ROOMEXTENSIONS.

3/16" HIGH PRESSURE HOSE

3/16" HIGHPRESSUREHOSE

PRESSUREREDUCINGVALVE

IMPORTANT: THE HOSES FROM THE ROD END OF THE UPPER CYLINDERSMUST CONNECT TO THE PRESSURE REDUCING VALVES.

3/16" HIGH PRESS-URE HOSE

NOTE: THE PRESSURE REDUCING VALVESMAY BE IN A DIFFERENT POSITION ON THESYNCHRONIZING CYLINDER. THEY WILL ALWAYS CONNECT TO THE ROD END OF THE UPPER CYLINDER.

IMPORTANT: HOSES 1 AND 2 MUST BE THE SAMELENGTH 3/16" HIGH PRESSURE HOSE. HOSES 5 AND 6MUST BE THE SAME LENGTH 3/16" HIGH PRESSURE HOSE.SOME EARLY SYSTEMS USED 1/8" HIGH PRESSURE HOSE.DO NOT MIX 1/8" HIGH PRESSURE AND 3/16" HIGH PRESS-URE HOSE.

HOSES 3 AND 4 MUST BE THE SAME LENGTH AND DIAMETER.HOSES 7 AND 8 MUST BE THE SAME LENGTH AND DIAMETER.

HOSE 1HOSE 2

HOSE 3

HOSE 4

3/16" HIGH PRESSURE HOSE HOSE 6

HOSE 7HOSE 8

HOSE 5

HOSE A

ROOM CYLINDERSTO CAP END OF

EXTEND VALVE

VALVE RELEASE NUTSSOLENOID VALVES WITHROOM MANIFOLD USING

RETRACTVALVE

HOSE A

VALVERELEASENUT

RELEASEVALVE

NUT

VALVERELEASE"T" HANDLES

RETRACTSOLENOIDVALVE

ROOMEXTENSIONMANIFOLD

CAP THIS FITTING

EXTEND SOLENOID VALVE

Page 17: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

ML23518/MP45.947A30MAR07

ROOM EXTENSION CYLINDER REPLACEMENT

DUAL CYLINDER FLAT FLOOR ROOM EXTENSION

READINSTRUCTIONS

PROCEEDINGBEFORETHOROUGHLYSTOP

(WITH SYNCHRONIZING CYLINDER)

1. Extend the room until the rod mounting pin is visible. Makesure the room is not starting to "LOWER". Support the room

3. Push the room control switch to "EXTEND" until both cylinders are fully extended.

4. Open the extend valve "T" handle or valve release nut.

5. Open the retract valve "T" handle or valve release nut.

NOTE: Valve release nuts should not be opened more than four (4) turns.

10. Install the rod end hose from the old cylinder onto the new cylinder.

11. Install the new cylinder. Support the cylinder so the rodeye does not catch the STORE-MORE mounting.

12. Install the trunnion bolts (2).

13. Attach the hoses to the new cylinder. DO NOT reversehose connections.

14. Remove hose A from the room extension manifold. Usea steel cap from the new cylinder to cap the fitting in themanifold. Direct hose A into the fluid reservoir.

15. Close the "T" handles or valve release nuts.

16. Push and hold the room control switch to "EXTEND" untilthe new cylinder is fully extended plus 5 seconds.

18. Reattach hose A to the room extension manifold.

20. Push and hold the room control switch to "RETRACT" until both cylinders are fully retracted plus five seconds. Repeat extending and retracting the cylinders AT LEAST 2more times or until the cylinders are running fully synchronized.

21. Fully extend the cylinders then retract the cylinders so the hole in the rod eye and inner tube line up and install the pin and snap rings for both cylinders. It may be necessary to loosen the trunnion jam nuts to line up the mounting holes. Make sure the trunnion (cylinder mounting nut) is in the same position after tightening the jam nuts.

22. Push the room control switch to "RETRACT" and hold until the room is fully retracted plus 5 seconds. Watch forexcessive racking of the room. Some racking can occur due to air in the system. If the room does not bind up, proceed toSTEP 24. If the room is bound up proceed to STEP 23.

23. If the room is bound up and the rod eye pins are not visible, repeat STEP 6 for both cylinders and manually do STEP 1 then 2. Repeat STEPS 12 and 20 thru 22. If the room will still not run properly, contact HWH Customer Service 1-800-321-3494.

24. Extend the room fully again. DO NOT reverse direction until the room is fully extended. Repeat retracting and ex-tending the room several times. DO NOT reverse directionsuntil the room is fully extended or retracted.

25. Check and make room adjustments in this order: drop,extend and then retract.

17. Open the extend valve then the retract valve "T" handlesor valve release nuts.

19. Close both valve "T" handles or valve release nuts.

existing hose end, tighten the hose end to snug plus 1/4tighten the hose end 1/3 turn (2 FLATS). If tightening anmake the hose end snug (finger tight) on the fitting, thenTightening of hose ends: If tightening a new hose end,

turn (1 FLAT).

IMPORTANT: The following instructions must be followed or air lock of the synchronizing cylinder and unsynchronized operation of the room cylinders may result causing damage to the room. Please read the instructions before replacing the cylinder. DO NOT reverse direction of the room unless the room is fully extended or retracted. IMPORTANT: When extending or retracting the cylinders

when the rod eye is not connected to the tube, the rod eye may catch on the STORE-MORE mounting. If necessary place a small block under both cylinders to raise the rod eye above the "STORE-MORE" mounting. Make sure it is not blocked so high it interferes with anything else in the tube. MOST OF ALL PAY ATTENTION.

2. Remove the mounting pin from both front and rear cylinders.

6. Remove trunnion bolts (2) that mount the rear of the cylinder that is to be changed.

7. Mark the hoses so they are replaced in the correct position. Remove and cap the hoses from the cylinder connections.

8. Remove the cylinder. The cylinder may need to be lifted slightly so the rod eye does not catch on the STORE-MORE mounting that protrudes inside of the inner tube.

9. Measure the cap end cylinder mounting nut on the bad cylinder. Make sure the mounting nut is in the same position on the new cylinder.

NOTE: Some rooms may need to be fully extendedand supported to access the pin.

Page 18: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

ML23518/MP45.947D20MAR01

CYLINDER REPLACEMENTDUAL CYLINDER "FLAT FLOOR" ROOM EXTENSION

WITH SYNCHRONIZING CYLINDER

RETRACTED POSITION ADJUSTMENT:LOOSEN NUTS ROTATE STOP BOLT TOADJUST RETRACTED POSITION IN OR OUT.TIGHTEN NUTS TO LOCK RETRACTED POSITION.

STOP BOLT

NUTS

DROP ADJUSTMENT PROCEDURE:LOOSEN JAM NUTS ROTATE JAM NUTS IN OR OUT TO MOVE DROP ADJUSTMENT UP OR DOWN.TIGHTEN JAM NUTS TO LOCK DROP ADJUSTMENT.

TRUNNIONJAM NUTS

TRUNNIONMOUNTINGBOLT (2)

CAP END HOSE CONNECTION

CONNECTION

ROD END HOSE

TRUNNION - CYLINDERMOUNTING NUT

VERTICAL ADJUSTMENT PROCEDURE:LOOSEN JAM NUT ROTATE PIVOT BOLTWITH 5/16 HEX KEY TO MOVE BRACKET UPOR DOWN. TIGHTEN JAM NUT TO LOCK VERTICAL ADJUSTMENT.

ROD MOUNTINGPIN

FLOOR SUPPORT ADJUSTMENT PROCEDURE:LOOSEN JAM NUT ROTATE STUD TO MOVE FLOORSUPPORT TUBE UP OR DOWN. TIGHTEN JAM NUTTO LOCK FLOOR ADJUSTMENT.

SYNCHRONIZING CYLINDER

STORE MOREMOUNTINGBOLT

ROD EYE

ROOM MANIFOLD USINGSOLENOID VALVES WITHVALVE RELEASE NUTS

EXTEND VALVE

VALVE RELEASE NUT

HOSE A

TO CAP END OF ROOM CYLINDERS

VALVERELEASE NUT

NOTE:ROD AND CAP END HOSE CONNECTIONS WILLBE THE SAME FOR MULTIPLE ROOM EXTENSIONS.

RETRACTSOLENOIDVALVE

SOLENOIDEXTEND

VALVE

ROOMEXTENSIONMANIFOLD

RETRACTVALVE

VALVERELEASE"T" HANDLES

FLUIDRESERVOIRFILL

CAP THIS FITTING

HOSE A TO CAP END OFROOM CYLINDERS

Page 19: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

ML21970/MP45.995314JUN06

SYNCHRONIZING CYLINDER ORHOSE ASSEMBLY REPLACEMENT

(WITH SYNCHRONIZING CYLINDER)

READINSTRUCTIONS

PROCEEDINGBEFORETHOROUGHLYSTOP

IMPORTANT: The following instructions must be followed or air lock of the synchronizing cylinder and unsynchronized operation of the room cylinders mayresult causing damage to the room. Please read the instructions before replacing the cylinder. DO NOTreverse direction of the room unless the room is fully extended or retracted.

NOTE: If the system uses a reversible pump instead of a room manifold, open the one emergency retract valve.

1. Remove and cap the hoses to the synchronizing cylinder.

NOTE: DO NOT remove the caps from the new cylinder hose connections until you are ready to attach the hoses.Save the caps.

2. Replace the synchronizing cylinder and reattach the hosesto the proper connections. DO NOT over tighten the hoseconnections.

1. Remove hose A from the room extension manifold. Use acap from the new cylinder to cap the fittings in the manifold.Direct hose A into the fluid reservoir.

2. Close the extend and retract valve "T" handles/Valve

pump is used.)

existing hose end, tighten the hose end to snug plus 1/4tighten the hose end 1/3 turn (2 FLATS). If tightening anmake the hose end snug (finger tight) on the fitting, thenTightening of hose ends: If tightening a new hose end,

turn (1 FLAT).

release nuts. (The emergency retract valve if a reversibleRefer to the correct room cylinder replacement sheet forinformation concerning room cylinder removal andreplacement and any adjustments that need to be made.

1. Fully extend or retract the room according to the correctroom cylinder replacement sheet.

2. Disconnect the end of both rods from the room extensionmechanism.

3. Retract the rods completely.

replacing the synchronizing cylinder or hose assembly.NOTE: Room cylinders must be fully retracted before

4. Loosen the extend valve "T" handle.

5. Loosen the retract valve "T" handle.

SYNCHRONIZING CYLINDER REPLACEMENT

HOSE ASSEMBLY REPLACEMENT

Remove and replace the hose assembly. Tighten the hose ends according to the above tightening procedure.

3. Extend the rods completely. Hold the room controlswitch on for five seconds after the rods are fully extended.

Refer to the correct room cylinder replacement sheet tocomplete the bleed procedure. Start where the instructionsreattach hose A to the pump assembly, or continue on this

ALL DUAL CYLINDER ROOM EXTENSIONS

BLEEDING PROCEDURE

sheet.

4. Open the cylinder extend valve first, then the cylinderretract valve.

5. Reattach hose A to the manifold fitting and tighten. Close the solenoid valves.

6. Retract and extend the cylinders until they are runningtogether. Cycle the cylinders at least three times, more ifneeded to synchronize the cylinders. Hold the switch about5 seconds each time the cylinders are fully extended or retracted.

7. Reattach the cylinders to the room mechanism.

8. Extend and retract the room several times to make surethe room is synchronized. Watch the room closely and release the room switch immediately if the room starts torack.

If the room will not synchronize, contact HWH for assistance.

Page 20: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

HOSE A

THIS LINEGOES TOTHE TANK

ML21970/MP45.995414JUN06

SY

NC

HR

ON

IZIN

G C

YLIN

DE

R

CAP ENDROD END

ROOM CYLINDER

ROOM CYLINDER

ROD END CAP END

ALL DUAL CYLINDER ROOM EXTENSIONS

POWER UNITWITH ROOMEXTENSION MANIFOLD

BREATHER/FILLER CAP

MOTOR

TANK

EMERGENCYRETRACT VALVE

SYNCHRONIZING TO CAP END OF

CYLINDER

BREATHER/FILLER CAP

THIS LINE GOESHOSE A

TO THE TANK

TO CAP ENDOF ROOMCYLINDERS

FITTING A

CAP THISFITTING

REVERSIBLEPOWER UNIT

ROOM MANIFOLD USINGSOLENOID VALVES WITHVALVE RELEASE

SOLENOID VALVE

TO CAP END OF ROOM CYLINDERS

CAP THISFITTING

RETRACTSOLENOIDVALVEVALVE

RELEASE "T" HANDLES

EXTEND SOLENOIDVALVE

ROOM EXTENSIONMANIFOLD

NUTS

VALVERELEASENUT

HOSE A

SOLENOID VALVE

VALVERELEASENUT

BREATHER/FILLER CAP

ALL DUAL CYLINDER ROOM EXTENSIONS(WITH SYNCHRONIZING CYLINDER)

HOSE ASSEMBLY REPLACEMENTSYNCHRONIZING CYLINDER OR

CYLINDER RETRACT

CYLINDER EXTEND

CYLINDER

CYLINDER

Page 21: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

MP65.302K10SEP02

CYLINDER CONNECTION DIAGRAM

DUAL CYLINDER ROOM EXTENSIONS

ROD END HIGH PRESSUREHOSE CONNECTION

CAP ENDHOSE CONNECTION

HOSE CONNECTION AT REAR OFROOM EXTENSION TUBE

VIEW 1

SY

NC

HR

ON

IZIN

G C

YLIN

DE

R

HYDRAULIC CYLINDER

HYDRAULIC CYLINDER

STEEL TUBE

ROD END CAP END

ROD END CAP END

STEEL TUBE

HIGHPRESSURE HOSE (B1)

HIGH PRESSURE HOSE (B1)

VIEW 1DUAL CYLINDER ROOM EXTENSION

(A1)

(A1)

CAP END CONNECTION - AROD ENDCONNECTION - B

IMPORTANT: THE LINES (A1) BETWEEN THE CAP END OF THE HYDRAULIC CYLINDERS AND THE TEEMUST BE THE SAME LENGTH AND DIAMETER. THE LINES (B1) BETWEEN THE ROD END OF THE HYDRAULIC CYLINDERS AND THE SYNCHRONIZING CYLINDER MUST BE THE SAME LENGTH AND DIAMETER. THE B1 LINES MUST BE HIGH PRESSURE HOSE.

(WITH SYNCRONIZING CYLINDER)

NOTE: THESE CONNECTIONS ARETHE SAME FOR EACH ROOM EXTENSIONWITH DUAL ROOM CYLINDERS ANDSYNCHRONIZING CYLINDER. NOT ALL

TEE

1/8" OR 3/16" HOSE BEING REPLACED MUST MATCH THE ORIGINAL HOSE. ALL HWH 1/4" HOSE IS THE SAME.DIFFERENT TYPES OF HOSE, ESPECIALLY HIGH PRESSURE HOSE, HAS BEEN USED. THE PRINTING ON ANOTE:

ROOMS USE THE STEEL TUBE.

Page 22: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

MP65.390F18OCT00

ROOM 1 (FRONT)

NOTE: HYDRAULIC PUMP SHOWN WITHROOM EXTENSION MANIFOLD ONLY.THE LEVELING SYSTEM MANIFOLD (NOT SHOWN)IS MOUNTED ON TOP OF THE ROOM EXTENSION MANIFOLD.

2R

2E

1R

1E

SEE HYDRAULIC LINECONNECTION DIAGRAMSFOR ROOM EXTENSIONSFOR SPECIFIC CYLINDERCONNECTION DIAGRAMS

CONNECTION DIAGRAMSFOR SPECIFIC CYLINDERFOR ROOM EXTENSIONSCONNECTION DIAGRAMSSEE HYDRAULIC LINE

ROOM 2 (REAR)

VALVE RELEASE"T" HANDLE

CAP END CONNECTION - A

ROD ENDCONNECTION - B

CAP END CONNECTION - A

ROD END CONNECTION - B

HYDRAULIC LINE CONNECTION DIAGRAMROOM EXTENSION - ONE OR TWO ROOMS

SOLENOID VALVES WITH VALVE RELEASE "T" HANDLES

SPRING

CHECK VALVE

CAP POPPET

O-RING

Page 23: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

MP65.390H20MAR01

ROOM 1 (FRONT)

NOTE: HYDRAULIC PUMP SHOWN WITHROOM EXTENSION MANIFOLD ONLY. THE LEVELINGSYSTEM MANIFOLD (NOT SHOWN) IS MOUNTED ONTOP OF THE ROOM EXTENSION MANIFOLD.

SEE HYDRAULIC LINECONNECTION DIAGRAMSFOR ROOM EXTENSIONSFOR SPECIFIC CYLINDERCONNECTION DIAGRAMS

CONNECTION DIAGRAMSFOR SPECIFIC CYLINDERFOR ROOM EXTENSIONSCONNECTION DIAGRAMSSEE HYDRAULIC LINE

ROOM 2 (REAR)

CAP END CONNECTION - A

ROD ENDCONNECTION - B

CAP END CONNECTION - A

ROD END CONNECTION - B

HYDRAULIC LINE CONNECTION DIAGRAMROOM EXTENSION - ONE OR TWO ROOMS

SOLENOID VALVES WITH VALVE RELEASE NUTS

ROOM 1 EXTENDSOLENOIDVALVE

VALVERELEASENUT

ROOM 2EXTENDSOLENOIDVALVE

ROOM 2RETRACTSOLENOIDVALVE

ROOM 1RETRACTSOLENOIDVALVE

VALVERELEASENUT

DETAIL A

SPRING

CAP

O-RING

POPPET

CHECKVALVEDETAIL A

Page 24: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

MP65.390Q19JUL01

ROD ENDCONNECTION - B

CONNECTION - ACAP END

ROD END CAP END

ROD END CAP END

ROD END CAP END

ROD END CAP END

UPPER CYLINDERS

1/8" LINE

1/8" HIGH PRESSURE LINE 1/8" LINE

TEEASSY.PRESSURE REDUCING VALVES

1/8" HIGHPRESSURE LINE

1/8" LINE

1/8" LINE

LOWER CYLINDERS

IMPORTANT: THE TWO LINES BETWEEN THE CAP END OF THE LOWER CYLINDERS AND THE TEE ASSEMBLYMUST BE THE SAME LENGTH AND DIAMETER.

THE TWO LINES BETWEEN THE ROD END OF THE LOWER CYLINDERS AND THE SYNCHRONIZING CYLINDERMUST BE HIGH PRESSURE HOSE THAT IS THE SAME LENGTH AND DIAMETER.

THE TWO LINES BETWEEN THE CAP END OF THE UPPER CYLINDERS AND THE TEE ASSEMBLY MUST BE THE SAME LENGTH AND DIAMETER.

THE TWO LINES BETWEEN THE ROD END OF THE UPPER CYLINDERS AND THE SYNCHRONIZING CYLINDERMUST BE HIGH PRESSURE HOSE THAT IS THE SAME LENGTH AND DIAMETER.

HYDRAULIC LINE CONNECTION DIAGRAMFOUR CYLINDER ROOM EXTENSION(WITH SYNCHRONIZING CYLINDER)

!NOTE: THE PRESSURE REDUCING VALVES MAY BE IN A DIFFERENTPOSITION ON THE SYNCHRONIZINGCYLINDER. THEY WILL ALWAYS CONNECT TO THE ROD END OF THEUPPER CYLINDERS.

1/8" HIGHPRESSURELINE

Page 25: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

HYDRAULIC FLOW DIAGRAM

MP65.945510NOV03

FIXED TOVEHICLE

FRONT CYLINDER

VERTICAL ARM OR DUAL CYLINDER ROOM EXTENSION

REAR CYLINDER

VEHICLEFIXED TO

STATIONARY POSITION

PRESSURE

RETURN

SYNCHRONIZING CYLINDER

SYNCHRONIZINGVALVE

SYNCHRONIZINGVALVE

WITH SYNCHRONIZING CYLINDER

EXTENDCYLINDER

VALVERETRACTVALVE

CYLINDER

Page 26: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

HYDRAULIC FLOW DIAGRAM

MP65.946K15FEB00

FOUR CYLINDER ROOM EXTENSIONWITH SYNCHRONIZING CYLINDER

UPPER CYLINDER

UPPER CYLINDER

SYNCHRONIZING CYLINDER

LOWER CYLINDER

LOWER CYLINDER

PRESSURE

EXTENDVALVE

RETRACTVALVE

RETURN

SYNCHRONIZINGVALVE

PRESSUREREDUCINGVALVE

SYNCHRONIZINGVALVE

REDUCINGPRESSURE

VALVE

Page 27: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

MP85.317C05DEC00

ELECTRICAL CONNECTIONDIAGRAMS

FOR:COACHES WITH TWO ROOM EXTENSIONS

ONE FLAT FLOOR OR

310 SERIES LEVELING SYSTEM

DUAL CYLINDER ROOM EXTENSION(WITH SYNCRONIZING CYLINDER)

ANDONE FOUR CYLINDER ROOM EXTENSION

(WITH SYNCRONIZING CYLINDER)

Page 28: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

TWO ROOM EXTENSION SYSTEM

ELECTRICAL CONNECTION DIAGRAM

VIEW FROM PUMP END

2E

2R

B A

B A

1R

1E

HYDRAULIC MANIFOLD

HARNESS GROUNDINGSEE POWER UNIT

SOLENOID VALVEROOM 1 - EXTEND

REAR OF PUMPVIEW FROM

INSTRUCTIONS

NOTE:

ROOM EXTENSION

MP85.321C19SEP00

AB

AB

SEE PUMPRELAY WIRINGDIAGRAM

JACKINTERRUPT INTERRUPT

JACK

ROOM 1 ROOM 2

OEM ROOMCONTROLHARNESS

SWITCHED +12BATTERY -6810 (CCZ)

ROOM 1RETRACT -5100 (DU)

ROOM 1 EXTEND -5000 (DR)

ROOM 2RETRACT -5101 (BBN)

ROOM 2EXTEND -5001 (BBM)

NO CONNECTION

+12 BATTERY -6100 (CCY)

ROOM 1 PUMP CONTROL -8602 (DDA)

DETAIL A

8601

SEE DETAIL A(9 PIN FEMALE)

HWH POWER / WARNING /INTERRUPT HARNESS

* FOR SPECIFIC WIRING DIAGRAMSAND INFORMATION REFER TO O.E.M.

DO NOT REVERSEWIRE COLORS TOA & B ON PACKARDCONNECTORS

VALVE RELEASE"T" HANDLE

ROOM 2 EXTENDSOLENOID VALVE

ROOM 2 RETRACTSOLENOID VALVE

ROOM 1 RETRACTSOLENOID VALVE

500062455100

62465001

62465101 6245

ROOM EXTENSIONPUMP/MANIFOLDHARNESS

LEVELINGSYSTEMMANIFOLD

EXTEND(DR)

RETRACT(DU)

SWITCHED +12BATTERY(CCZ)

PUMP CONTROL (DDK)+12 BATTERY (CCY)EXTEND (BBM)RETRACT (BBN)

ROOM CONTROLSWITCHES BY OEM*

PUMPCONTROL(DDA)

ROOM 2PUMP CONTROL -8601 (DDK)

THE PUMP/MANIFOLD ASSEMBLY.BETWEEN THE HARNESS ANDNOTE: THERE MAY BE PLUGS

310 SERIES LEVELING SYSTEM

Page 29: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

TWO ROOM EXTENSION SYSTEM (ONE FOUR CYL ROOM EXTENSION)ELECTRICAL CONNECTION DIAGRAM

SEE GROUNDINGINSTRUCTIONS

MP85.321J04DEC00

JACKINTERRUPT INTERRUPT

JACK

ROOM 1 ROOM 2

OEM ROOMCONTROLHARNESS

SWITCHED +12BATTERY -6810 (CCZ)

ROOM 1RETRACT -5100 (DU)

ROOM 1 EXTEND -5000 (DR)

ROOM 2RETRACT -5101 (BBN)

ROOM 2EXTEND -5001 (BBM)

NO CONNECTION

+12 BATTERY -6101 (CCY)

ROOM 1 PUMP CONTROL -8602 (DDA)

DETAIL A

8601

SEE DETAIL A(9 PIN FEMALE)

HWH POWER / WARNING /INTERRUPT HARNESS

* FOR SPECIFIC WIRING DIAGRAMSAND INFORMATION REFER TO O.E.M.

DO NOT REVERSEWIRE COLORS TOA & B ON PACKARDCONNECTORS

ROOM EXTENSIONPUMP/MANIFOLDHARNESS

EXTEND(DR)

RETRACT(DU)

SWITCHED +12BATTERY(CCZ)

PUMP CONTROL (DDK)+12 BATTERY (CCY)EXTEND (BBM)RETRACT (BBN)

ROOM CONTROLSWITCHES BY OEM*

PUMPCONTROL(DDA)

ROOM 2PUMP CONTROL -8601 (DDK)

TOP VIEW OF

BA

PUMP/MANIFOLD

NOTE: LEVELING SYSTEMMANIFOLD NOT SHOWN

AB

SEE ELECTRICALCONNECTION DIAGRAMROOM EXTENSIONPUMP RELAY

BA

BA

6246500162455000

51006245

62465101

ROOM 1 EXTENDSOLENOID VALVE

ROOM 1 RETRACT SOLENOID VALVE

VALVE RELEASE NUT

ROOM 2 EXTENDSOLENOIDVALVE

ROOM 2 RETRACTSOLENOID VALVE

VALVERELEASE NUT

THE PUMP/MANIFOLD ASSEMBLY.BETWEEN THE HARNESS ANDNOTE: THERE MAY BE PLUGS

7456

8123

7 8

6 3

45

12

SOLENOID VALVES WITH VALVE RELEASE NUTS310 SERIES LEVELING SYSTEM

Page 30: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

ELECTRICAL CONNECTION DIAGRAM

MP85.322J05DEC00

310 SERIES LEVELING SYSTEM PUMP RELAYSWITH TWO ROOM EXTENSIONS

SEE ELECTRICALCONNECTION DIAGRAMROOM EXTENSIONPUMP RELAY

FROM CONTROLBOX

LEVELING SYSTEMPUMP/MANIFOLDHARNESS

SEE GROUNDINGINSTRUCTIONSLEVELING SYSTEM

MANIFOLD CONNECTIONS

FUSE40 AMP

6100

8600

MAY BE CONNECTEDTO EITHER RELAY

86036101

68108602

RELAY BROOM EXTENSION SYSTEM

+12 FROMBATTERY

9000

6231

RELAY ALEVELING SYSTEM

+12 FORPUMP MOTOR

4 CYLINDER ROOM EXTENSIONPRESSURE SWITCH INTERRUPTRELAY - SEE ELECTRICALCONNECTION DIAGRAM - ROOMEXTENSION PUMP RELAY

7695

8601

8603

RELAY B

RELAY ARELAY B

THE PUMP/MANIFOLD ASSEMBLY.BETWEEN THE HARNESS ANDNOTE: THERE MAY BE PLUGS

CDB

A

Page 31: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

MP85.322Q05DEC00

85 30

87A87

86

PU

MP

RE

LAY

CO

NT

RO

L(B

ED

RO

OM

)

SYNC. CYL.PSW.

TO

RE

LAY

PIG

TA

IL

SYNCHRONIZING CYLINDERPRESSURE SWITCH HARNESSSEE ELECTRICAL CONNECTIONDIAGRAM - SYNCHRONIZINGCYLINDER PRESSURE SWITCHES

8730

87A

85 86

RELAYINFORMATION

THE PRESSURE SWITCHINTERRUPT RELAY ISMOUNTED ON THE PUMP/MANIFOLD ASSEMBLYWITH PUMP RELAYS

FROM THE SYNCHRONIZING CYLINDER

NOTE: THE (4) DIGIT WIRENUMBER SUPERSEDES ANYAND ALL WIRE COLORS.

7695

7695(85)

8601(30+86)

4 CYLINDER ROOMEXTENSION PRESS.SWITCH INTERRUPTRELAY

FUSE20AMP

8603(87A)

6810

8602

FUSE20 AMP6101

SEE GROUNDINGINSTRUCTIONS

ROOM EXTENSIONPUMP/MANIFOLD HARNESS

SEE ELECTRICAL CONNECTIONDIAGRAM - ROOM EXTENSIONSYSTEM

TO RELAY A+12 FOR PUMPMOTOR

FROM THE LEVELINGSYSTEM PUMP/MANIFOLDHARNESS - GROUND SIGNALFROM PARK BRAKE SWITCH

(BLUE) 9000

RELAY B

FROM RELAY A+12 BATTERYSUPPLY

ELECTRICAL CONNECTION DIAGRAMROOM EXTENSION PUMP RELAY

TWO ROOM EXTENSIONS (ONE FOUR CYL ROOM EXTENSION)

8601

THE PUMP/MANIFOLD ASSEMBLY.BETWEEN THE HARNESS ANDNOTE: THERE MAY BE PLUGS

D

C

B

A

Page 32: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

MP85.324C05DEC00

85

30

87A 87

86

FOUR CYLINDER ROOM EXTENSIONPRESSURE SWITCH INTERRUPT RELAY - THE RELAY IS MOUNTED ONTHE PUMP/MANIFOLD ASSEMBLY WITHPUMP RELAYS

SEE ELECTRICAL CONNECTIONDIAGRAM - ROOM EXTENSIONPUMP RELAY7695

(85)

7695

TO GROUND STUDSEE GROUNDINGINSTRUCTIONS

6230

SYNCHRONIZING CYLINDERPRESSURE SWITCH HARNESS

THESE RING TERMINALSGO TO THE BOLT ON THEEND OF THE SYNCHRONIZINGCYLINDER

6230

7695 7695

6230 6230 6230

6230*

7695

SYNCHRONIZING CYLINDER

ELECTRICAL CONNECTION DIAGRAMROOM EXTENSION

SYNCHRONIZING CYLINDER PRESSURE SWITCHES

HARNESS MAY NOT BE PRESENT.SWITCHES WITH ONLY ONE WIRE. THIS GROUNDING*NOTE:NEWER SYSTEMS MAY HAVE PRESSURE

(MP85.505G)

Page 33: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

ELECTRICAL CONNECTION DIAGRAM310 SERIES LEVELING SYSTEM WITH ROOM EXTENSIONSPOWER HARNESS AND MASTER WARNING INDICATORS

+ _

5 AMP

10 A

MP

10 A

MP

10 A

MP

5 A

MP

10 A

MP

MP85.324G180CT00

THIS WIRECONNECTS DIRECTLYTO THE LEVELINGSYSTEM TOUCH PANEL

SEE ELECTRICAL CONNECTIONDIAGRAM - ROOM EXTENSIONSYSTEM

NE

GA

TIV

E

NE

GA

TIV

E7699

BUZZER+12

WARN.LIGHT +12

61116111

6120

8601

8601

7699

SEE DETAIL A

DETAIL A

IGNITION "ON"+12 VOLT (KE) - 6110

NOT USED

ACCESSORY+12 VOLT (LD) - 6120

JAC

KIN

TE

RR

UP

T

HARNESS BYO.E.M.

ROOM EXTENSIONPUMP/MANIFOLD HARNESS

8601

6110

6111

SAME AS (MP85304C)

Page 34: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

ELECTRICAL CONNECTION DIAGRAM

MP85.324K05DEC00

310 SERIES LEVELING SYSTEM WITH TWO ROOM EXTENSIONS

POWER UNIT/MANIFOLD PIGTAIL ASSEMBLY

COACHES BEFORE MID - YEAR 2000 DID NOT HAVE THE PIGTAIL ASSEMBLY. REFER TO THE DIAGRAMS IN THISMANUAL FOR CORRECT INFORMATION. COACHES BUILT AFTER MID - YEAR 2000 MAY HAVE THE PIGTAIL ASSEMBLY. COMPONENT CONNECTIONS WILL REMAIN THE SAME. THIS PAGE SHOWS THE PLUG CONNECTIONSFOR THE MAIN HARNESSES.

PIN 1

PIN 7

PIN 6PIN 7

PIN 6PIN 1PIN 7

PIN 6PIN 1

PIN 1 PIN 6

PIN 7PIN 1 PIN 4

PIN 5

PIN 5

PIN 4PIN 1PIN 4PIN 1

PIN 2

PIN 1

PIN 2

PIN 4

PIN 1 - 6100

PIN 2 - 6100

PIN 3 - 6230

PIN 4 - 6230

PIN 2 THRU 5 - N.C.

PIN 1 - 8600

PIN 3 - 2400

PIN 1 - N.C.

PIN 2 - 4400

PIN 2 - 8601 ROOM 2

PIN 1 - 8602

PIN 7 - N.C.

PIN 6 - 6810

PIN 6 - 8100

PIN 7 - 9000

PIN 8 - N.C. PIN 5 - 3400

PIN 4 - 1400

PIN 6 THRU 12 - N.C.

PIN 10 - 5100

PIN 11 - 5000

PIN 12 - 6101

+12 BATTERY

+12 BATTERY

GROUND

GROUND

LEVELINGSYSTEM PUMP RELAY

MANIFOLDPRESSURE SWITCH

GROUNDFROM PARK BRAKE

LR SOL. VALVE

RF SOL. VALVE

LF SOL. VALVE

RR SOL. VALVE

ROOM 1PUMP CONTROL

SWITCHEDBATTERY

ROOM 1RETRACT

ROOM 1EXTEND

+12 BATTERY

PUMP/MANIFOLD LEVELING SYSYTEM

LEVELING SYSTEM310 SERIES HYDRAULICCONNECTION DIAGRAMSEE ELECTRICAL

TO CONTROL BOX

HARNESS PUMP/MANIFOLD HARNESSROOM EXTENSION

ONE ROOM EXTENSIONCONNECTION DIAGRAMSEE ELECTRICAL

TO ROOM EXTENSION

SYSYTEM

CONTROLS

SEE ELECTRICAL CONNECTIONDIAGRAM - LEVELINGSYSTEM PUMP RELAYWITH TWO ROOMEXTENSIONS

SEE ELECTRICALCONNECTIONDIAGRAMS - LEVELING SYSTEM PUMP RELAY - ROOM EXTENSION PUMPRELAY - HYDRAULIC MANIFOLD 310 SERIESLEVELING SYSTEM

SEE ELECTRICALCONNECTIONDIAGRAM HYDRAULICMANIFOLD 310 SERIESLEVELING SYSTEM

SEE ELECTRICAL CONNECTION DIAGRAMS -TWO ROOM EXTENSIONSYSTEM - ROOM EXTENSION PUMP RELAY

PUMP CONTROL

PIN 3 THRU 5 - N.C.

PIN 8 - 5101 ROOM 2RETRACT

PIN 9 - 5001 ROOM 2EXTEND

Page 35: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

12MAY99MP85.325C

LEVELING SYSTEMMANIFOLD HARNESS

6240 6231

GROUP OF WHITE WIRES 6"FROM END OF LOOM TO BEGROUNDED TO STUD

6230GROUP OF WHITE WIRES 6"FROM END OF LOOM TO BEGROUNDED TO STUD

ROOM EXTENSION MANIFOLD HARNESS

3/8" EXTERNAL STARLOCK WASHER (4 USED)

3/8 -16 NUT(2 USED)

6230

GROUNDSTUD

62456246

PUMP MOUNTED REMOTE FROM FRAMEUSE GROUNDING STUD AND 3/8" EXTERNALSTAR LOCKWASHERS AS SHOWN.

IMPORTANT: STAR LOCK WASHERS MUST BEUSED BETWEEN GROUNDING SURFACE ANDWIRE TERMINALS.

SYNCHRONIZINGCYLINDERPRESSURESWITCH HARNESS

MANIFOLDGROUND -6233

GROUND STUD

ROOM EXTENSIONMANIFOLD HARNESS

GROUP OF WHITE WIRES 6"FROM END OF LOOM TO BE GROUNDED TO STUD

6245

3/8" INTERNAL STARLOCKWASHER (4 USED)

62463/8-16 NUT

SYNCHRONIZINGCYLINDER PRESSURESWITCH HARNESS

6230

GROUP OF WHITE WIRES 6" FROM END OF LOOM TO BE GROUNDED TO STUD

623062316240

PUMP MOUNTINGPOSITIONS

WELDED PUMP MOUNTUSING GROUNDING STUD AND 3/8" EXTERNALSTAR LOCKWASHERS AS SHOWN.

IMPORTANT: STAR LOCKWASHERS MUSTBE USED BETWEEN GROUNDING SURFACEAND WIRE TERMINALS.

LEVELING SYSTEMMANIFOLD HARNESS PUMP MOUNTING

CHANNEL

MANIFOLDGROUND -6233

GROUNDING INSTRUCTIONS310 SERIES LEVELING SYSTEM

(WITH ROOM EXTENSION)

ELECTRICAL CONNECTION DIAGRAM

Page 36: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

MP85.500H05DEC00

ELECTRICAL CONNECTIONDIAGRAMS

FOR:COACHES WITH TWO ROOM EXTENSIONS

ONE FLAT FLOOR OR

610 SERIES LEVELING SYSTEM

DUAL CYLINDER ROOM EXTENSION(WITH SYNCRONIZING CYLINDER)

ANDONE FOUR CYLINDER ROOM EXTENSION

(WITH SYNCRONIZING CYLINDER)

Page 37: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

VIEW FROM PUMP END

2E

2R

B A

B A

1R

1E

HYDRAULIC MANIFOLD

HARNESS GROUNDINGSEE POWER UNIT

SOLENOID VALVEROOM 1 - EXTEND

REAR OF PUMPVIEW FROM

INSTRUCTIONS

NOTE:

ROOM EXTENSION

MANIFOLDLEVELING SYSTEM

MP85.504F05DEC00

AB

AB

ROOM 1 ROOM 2

PUMP CONTROL (DDK)+12 BATTERY (CCY)EXTEND (BBM)

RETRACT (BBN)

RETRACT (DU)SWITCHED +12 BATT. (CCZ)

EXTEND (DR)

OEM ROOMCONTROLHARNESS

SWITCHED +12BATTERY -6810 (CCZ)

ROOM 1RETRACT -5100 (DU)

EXTEND - 5000 (DR)

ROOM 2RETRACT -5101 (BBN)

ROOM 2EXTEND -5001 (BBM)

NO CONNECTION

+12 BATTERY -6101 (CCY)

DETAIL A

SEE DETAIL A(9 PIN FEMALE)

* FOR SPECIFIC WIRING DIAGRAMSAND INFORMATION REFER TO O.E.M.

DO NOT REVERSEWIRE COLORS TOA & B ON PACKARDCONNECTORS

VALVE RELEASE"T" HANDLE

ROOM 2 EXTENDSOLENOID VALVE

ROOM 2 RETRACTSOLENOID VALVE

ROOM 1 RETRACTSOLENOID VALVE

500062455100

62465001

62465101 6245

ROOM 1PUMP CONTROL -8602 (DDA)

ROOM 2PUMPCONTROL -8601 (DDK)

ROOM 1

SEE ELECTRICALCONNECTION DIAGRAMROOM EXTENSIONPUMP RELAY

ROOM CONTROL SWITCHES BY OEM*

PUMP CONTROL (DDA)

THE PUMP/MANIFOLD ASSEMBLY.BETWEEN THE HARNESS ANDNOTE: THERE MAY BE PLUGS

ROOM EXTENSIONPUMP/MANIFOLD HARNESS

ELECTRICAL CONNECTION DIAGRAM

610 SERIES LEVELING SYSTEM WITH TWO ROOM EXTENSIONS

SOLENOID VALVES WITH VALVE RELEASE "T" HANDLES

7 84 15 26 3

7 8

6 35 24 1

Page 38: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

610 SERIES LEVELING SYSTEM WITH TWO ROOM EXTENSIONSELECTRICAL CONNECTION DIAGRAM

TOP VIEW OF

BA

MP85.504H05DEC00

SEE GROUNDINGINSTRUCTIONS

SOLENOID VALVES WITH VALVE RELEASE NUTS

PUMP/MANIFOLD

NOTE: LEVELING SYSTEMMANIFOLD NOT SHOWN

AB

SEE ELECTRICALCONNECTION DIAGRAMROOM EXTENSIONPUMP RELAY

BA

BA

6245500162455000

51006245

62455101

ROOM 1 EXTENDSOLENOID VALVE

ROOM 1 RETRACT SOLENOID VALVE

VALVE RELEASE NUT

ROOM 2 EXTENDSOLENOIDVALVE

ROOM 2 RETRACTSOLENOID VALVE

VALVERELEASE NUT

ROOM 1 ROOM 2

PUMP CONTROL (DDK)+12 BATTERY (CCY)EXTEND (BBM)

RETRACT (BBN)

RETRACT (DU)SWITCHED +12 BATT. (CCZ)

EXTEND (DR)

OEM ROOMCONTROLHARNESS

SWITCHED +12BATTERY -6810 (CCZ)

ROOM 1RETRACT -5100 (DU)

EXTEND - 5000 (DR)

ROOM 2RETRACT -5101 (BBN)

ROOM 2EXTEND -5001 (BBM)

NO CONNECTION

+12 BATTERY -6101 (CCY)

DETAIL A

SEE DETAIL A(9 PIN FEMALE)

* FOR SPECIFIC WIRING DIAGRAMSAND INFORMATION REFER TO O.E.M.

DO NOT REVERSEWIRE COLORS TOA & B ON PACKARDCONNECTORS

ROOM 1PUMP CONTROL -8602 (DDA)

ROOM 2PUMPCONTROL -8601 (DDK)

ROOM 1

ROOM CONTROL SWITCHES BY OEM*

PUMP CONTROL (DDA)

THE PUMP/MANIFOLD ASSEMBLY.BETWEEN THE HARNESS ANDNOTE: THERE MAY BE PLUGS

ROOM EXTENSIONPUMP/MANIFOLD HARNESS

7 8

6 35 24 1

6 3

4 17 8

5 2

Page 39: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

ELECTRICAL CONNECTION DIAGRAM

MP85.504J05DEC00

610 SERIES LEVELING SYSTEM WITH TWO ROOM EXTENSIONSMASTER AND PUMP RELAY

SEE ELECTRICALCONNECTION DIAGRAMROOM EXTENSIONPUMP RELAY

RELAY CROOM EXTENSIONPUMP RELAY

FROM CONTROLBOX

LEVELING SYSTEMPUMP/MANIFOLDHARNESSSEE GROUNDING

INSTRUCTIONS

SEE ELECTRICAL CONNECTIONDIAGRAM - MANIFOLD - 610SERIES LEVELING SYSTEM

FUSE40 AMP

(BLACK)6800

(RED)8500

TO PUMPMOTOR

FROMBATTERY

(WHITE)6231

(GRAY)8600

RELAY BLEVELINGSYSTEMPUMP RELAY

(BLUE)9000

RELAY A

RELAY C

4 CYLINDER ROOM EXTENSIONPRESSURE SWITCH INTERRUPTRELAY - SEE ELECTRICALCONNECTION DIAGRAM - ROOMEXTENSION PUMP RELAY

RELAY A

7695

8601

8603

RELAY C

RELAY B

NOTE: THE (4) DIGIT WIRE NUMBERSUPERSEDES ANY AND ALL WIRE COLORS.

RELAY A(MASTER RELAY)

THE PUMP/MANIFOLD ASSEMBLY.BETWEEN THE HARNESS ANDNOTE: THERE MAY BE PLUGS

6230

Page 40: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

MP85.504M05DEC00

85 30

87A87

86

JACKINT.

JACKINT.

PU

MP

RE

LAY

CO

NT

RO

L(B

ED

RO

OM

)

SYNC. CYL.PSW.

TO

RE

LAY

PIG

TA

IL

SYNCHRONIZING CYLINDERPRESSURE SWITCH HARNESSSEE ELECTRICAL CONNECTIONDIAGRAM - SYNCHRONIZINGCYLINDER PRESSURE SWITCHES

8730

87A

85 86

RELAYINFORMATION THE PRESSURE SWITCH

INTERRUPT RELAY ISMOUNTED ON THE PUMP/MANIFOLD ASSEMBLYWITH THE MASTER ANDPUMP RELAYS

FROM THE SYNCHRONIZING CYLINDER

FROM THE CONTROL BOX

LEVELING SYSTEMPUMP/MANIFOLDHARNESS - SEEELECTRICAL CONNECTIONDIAGRAM - HYDRAULICLEVELING SYSTEM

NOTE: THE (4) DIGIT WIRENUMBER SUPERSEDES ANYAND ALL WIRE COLORS.

7695

7695(85)

8601(30+86)

4 CYLINDER ROOMEXTENSION PRESS.SWITCH INTERRUPTRELAY

FUSE20AMP

8603(87A)

6810

8602

FUSE20 AMP6100

SEE GROUNDINGINSTRUCTIONS

ROOM EXTENSIONPUMP/MANIFOLD HARNESS

SEE ELECTRICAL CONNECTIONDIAGRAM - ROOM EXTENSIONSYSTEM

TO RELAY B -+12 FOR PUMPMOTOR

FROM THE LEVELINGSYSTEM PUMP/MANIFOLDHARNESS - GROUND SIGNALFROM PARK BRAKE SWITCH

(BLUE) 9000

RELAY C

FROM RELAY A+12 BATTERYSUPPLY

ELECTRICAL CONNECTION DIAGRAMROOM EXTENSION PUMP RELAY

TWO ROOM EXTENSIONS (ONE FOUR CYL ROOM EXTENSION)

8601

THE PUMP/MANIFOLD ASSEMBLY.BETWEEN THE HARNESS ANDNOTE: THERE MAY BE PLUGS

8601 8601

D

C

BA

Page 41: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

ELECTRICAL CONNECTION DIAGRAM

MP85.504R05DEC00

610 SERIES LEVELING SYSTEM WITH TWO ROOM EXTENSIONS

POWER UNIT/MANIFOLD PIGTAIL ASSEMBLY

COACHES BEFORE MID - YEAR 2000 DID NOT HAVE THE PIGTAIL ASSEMBLY. REFER TO THE DIAGRAMS IN THISMANUAL FOR CORRECT INFORMATION. COACHES BUILT AFTER MID - YEAR 2000 MAY HAVE THE PIGTAIL ASSEMBLY. COMPONENT CONNECTIONS WILL REMAIN THE SAME. THIS PAGE SHOWS THE PLUG CONNECTIONSFOR THE MAIN HARNESSES.

PIN 1

PIN 7

PIN 6PIN 7

PIN 6PIN 1PIN 7

PIN 6PIN 1

PIN 1 PIN 6

PIN 7PIN 1 PIN 4

PIN 5

PIN 5

PIN 4PIN 1PIN 4PIN 1

PIN 2

PIN 1

PIN 2

PIN 4

PIN 1 - 6800 SWITCHED

PIN 2 - 6800 SWITCHED

PIN 3 - 6230

PIN 4 - 6230

PIN 2 - 8500 MASTER

PIN 1 - 8600

PIN 3 - 2400

PIN 1 - N.C.

PIN 2 - 4400

PIN 2 - 8601 ROOM 2

PIN 1 - 8602

PIN 7 - N.C.

PIN 6 - 6810

PIN 3 - 8601 JACK

PIN 4 AND 5 - N.C.

PIN 6 - 8100 MANIFOLD

PIN 5 - 3400

PIN 4 - 1400

PIN 6 AND 7 - N.C.PIN 10 - 5100

PIN 11 - 5000

PIN 12 - 6101

BATTERY

BATTERY

GROUND

GROUND

LEVELINGSYSTEM PUMP RELAY

INTERRUPT

LR SOL. VALVE

RF SOL. VALVE

LF SOL. VALVE

RR SOL. VALVE

ROOM 1PUMP CONTROL

SWITCHEDBATTERY

ROOM 1RETRACT

ROOM 1EXTEND

+12 BATTERY

PUMP/MANIFOLD LEVELING SYSYTEM

LEVELING SYSTEM610 SERIES HYDRAULICCONNECTION DIAGRAMSEE ELECTRICAL

TO CONTROL BOX

HARNESS PUMP/MANIFOLD HARNESSROOM EXTENSION

TWO ROOM EXTENSIONCONNECTION DIAGRAMSEE ELECTRICAL

TO ROOM EXTENSION

SYSYTEM

CONTROLS

SEE ELECTRICAL CONNECTIONDIAGRAM - LEVELINGSYSTEM MASTER ANDPUMP RELAY WITHTWO ROOM EXTENSION

SEE ELECTRICALCONNECTION DIAGRAMS - LEVELING SYSTEMMASTER AND PUMPRELAY - ROOM EXTENSIONPUMP RELAY - HYDRAULICMANIFOLD 610 SERIESLEVELING SYSTEM

SEE ELECTRICALCONNECTIONDIAGRAM HYDRAULICMANIFOLD 610 SERIESLEVELING SYSTEM

SEE ELECTRICAL CONNECTION DIAGRAMS -TWO ROOM EXTENSIONSYSTEM - ROOM EXTENSION PUMP RELAY

PUMP CONTROL

PIN 3 THRU 5 - N.C.

RELAY

PRESSURE SWITCH

FROM PARK BRAKEPIN 7 - 9000 GROUND

PIN 8 - N.C.

GROUNDPIN 8 - 7601 LR

GROUNDPIN 9 - 7600 RF

PIN 10 AND 12 - N.C.

PIN 9 - 5001 ROOM 2EXTEND

PIN 8 - 5101 ROOM 2RETRACT

Page 42: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

MP85.504U17SEP02

+ _

5 AMP

10 A

MP

10 A

MP

10 A

MP

5 A

MP

10 A

MP

BUZZER+12

WARN.LIGHT +12

IGNITION "ON"+12 VOLT -(PURPLE) 6110

NOT USED

ACCESSORY+12 VOLT -(BROWN) 6120

O.E.M. POWERHARNESS

(PURPLE)6110

(BROWN) 6120

+12 FROM ACC. -(BROWN) 6120

SEE ELECTRICAL CONNECTIONDIAGRAM - ROOM EXTENSIONPUMP RELAY

JACKINTERRUPT

BUZZER

7699

(PURPLE)6111 6111

(PURPLE)

NOTE: THE (4) DIGIT WIRE NUMBERSUPERSEDES ANY AND ALL WIRE COLORS.

8601SEE CONTROL BOXCONNECTIONINFORMATION

ELECTRICAL CONNECTION DIAGRAM

610 SERIES LEVELING SYSTEM WITH ROOM EXTENSIONS

POWER HARNESS AND MASTER WARNING INDICATORS

7699

FROM PUMP/MANIFOLDHARNESS

8601

(BROWN)6120

6111

6110

Page 43: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

MP85.505G06DEC00

85

30

87A 87

86

FOUR CYLINDER ROOM EXTENSIONPRESSURE SWITCH INTERRUPT RELAY - THE RELAY IS MOUNTED ONTHE PUMP/MANIFOLD ASSEMBLY WITHTHE MASTER AND PUMP RELAYS

SEE ELECTRICAL CONNECTIONDIAGRAM - ROOM EXTENSIONPUMP RELAY

7695(85)

7695

TO GROUND STUDSEE GROUNDINGINSTRUCTIONS

6230

SYNCHRONIZING CYLINDERPRESSURE SWITCH HARNESS

THESE RING TERMINALSGO TO THE BOLT ON THEEND OF THE SYNCHRONIZINGCYLINDER

6230

7695 7695

6230 6230 6230

6230*

7695

SYNCHRONIZING CYLINDER

ELECTRICAL CONNECTION DIAGRAMROOM EXTENSION

SYNCHRONIZING CYLINDER PRESSURE SWITCHES

HARNESS MAY NOT BE PRESENT.SWITCHES WITH ONLY ONE WIRE. THIS GROUNDING*NOTE:NEWER SYSTEMS MAY HAVE PRESSURE

(MP85.324C)

Page 44: · PDF file · 2013-03-26room extension pump/manifold harness to the Winnebago room control harness. Check for +12 power on the 6101 wire (CCY) at the connection. If power is not

23FEB99MP85.505O

LEVELING SYSTEMMANIFOLD HARNESS

6240 6231

GROUP OF WHITE WIRES 6"FROM END OF LOOM TO BEGROUNDED TO STUD

6230GROUP OF WHITE WIRES 6"FROM END OF LOOM TO BEGROUNDED TO STUD

ROOM EXTENSION MANIFOLD HARNESS

3/8" EXTERNAL STARLOCK WASHER (4 USED)

3/8 -16 NUT(2 USED)

6230

GROUNDSTUD

62456246

PUMP MOUNTED REMOTE FROM FRAMEUSE GROUNDING STUD AND 3/8" EXTERNALSTAR LOCKWASHERS AS SHOWN.

IMPORTANT: STAR LOCK WASHERS MUST BEUSED BETWEEN GROUNDING SURFACE ANDWIRE TERMINALS.

SYNCHRONIZINGCYLINDERPRESSURESWITCH HARNESS

WHITE FROMPRESSURE SWITCH

GROUND STUD

ROOM EXTENSIONMANIFOLD HARNESS

GROUP OF WHITE WIRES 6"FROM END OF LOOM TO BE GROUNDED TO STUD

6245

3/8" INTERNAL STARLOCKWASHER (4 USED)

62463/8-16 NUT

SYNCHRONIZINGCYLINDER PRESSURESWITCH HARNESS

6230

GROUP OF WHITE WIRES 6" FROM END OF LOOM TO BE GROUNDED TO STUD

623062316240

PUMP MOUNTINGPOSITIONS

WELDED PUMP MOUNTUSING GROUNDING STUD AND 3/8" EXTERNALSTAR LOCKWASHERS AS SHOWN.

IMPORTANT: STAR LOCKWASHERS MUSTBE USED BETWEEN GROUNDING SURFACEAND WIRE TERMINALS.

LEVELING SYSTEMMANIFOLD HARNESS PUMP MOUNTING

CHANNEL

WHITE FROM PRESSURESWITCH

GROUNDING INSTRUCTIONS610 SERIES LEVELING SYSTEM

WITH ROOM EXTENSION