LUNEAU TECHNOLOGY USA224 James St. Bensenville, IL 60106 - (800) 729-1959 - www.luneautechusa.com

Dimensions 2 VX25 space saving chart

H 25.98 in. (660 mm) x W 12.60 in. (320 mm) x D 12.79 in (325 mm) Weight 55.12 lbs (25 kg)

VX40 Wavefront analyser H 17.90 in. (455 mm) x W 8.66 in. (220 mm) x D 9.44 in. (240 mm) Weight 20 lbs (9 kg) Eye Refract Table Adjustable height side from 26.57 to 36.42 in. (675 to 925 mm) x W 42.91 in. (1090 mm) x D 18.11 in. (460 mm) Weight 38,5 Kgs (83.78 lbs) VX40 console H 32.60 in. (828 mm) x W 12.60 in. (320 mm) x D 14.13 in. (359 mm)

configuration

• Eye RefractTM

• VX25• VX40• Table VX40• Table VX25-ER

30230000-008225-0000-003014-0000-008160-8025-00 8160-0025-00

REF.

EYE REFRACTTM

Output • RS232 / USB2.0 / VGA / LAN• Embedded bluetooth / Wifi

Hardware Tablet ...............................................................AndroidChinrest ...........................................................ElectricalNear Vision Target .......................................... 250-700 mm

Mini tablet 7“Head ................................................................Autofocus, autocentering

Range Sph ..................................................................-30.00D to +27.25D Sph step ..........................................................0.125 / 0.25 / 0.50 / 1 DCyl....................................................................-6.00 to +6.00 DCyl step ...........................................................0.25 / 0.50 / 1 DOptical axis .....................................................0 to 180°Axis step .........................................................1° / 5° / 10° / 45°Prisms ..............................................................0 to 20 D

Communication

Technical Specifications

TM

Height 19.3 in (490 mm)

Width 11.4 in (290 mm)

Depth 18.5 in (470 mm)

Weight 55 lbs (25 kg)

Power100/120, 220/240 V AC, 50/60 Hz

Voltage230 V 50 / 60 Hz

1

2

3

4

4

5

3

1

5

Comfort zone

Eye Refract lets you Delegate Refractions with confidence.The Eye Refract system uses dual, Shack-Hartmann wavefront aberrometers, combined with a fully automated digital phoropter, to deliver highly accurate and reproducible refractions in less than 4 minutes. The tablet-driven process can be conducted by a staff member with limited training while still delivering consistent results.

Valid and reproducible results

Results first published in the ARVO Journal (August 2018) demonstrated Eye Refract strongly correlates with traditional refraction, showing no statistical differences between the two methodologies. Finally, Eye Refract delivered results faster as compared to conventional subjective refraction.

Spherical equivalent Optometrists (Subjective) vs Eye Refract (Eyer)

EyeRefract identifies the patient’s comfort zone by searching in 3 dimensions: Sphere, Cylinder, and Axis.

The 2018 Madrid Study demonstrates Eye Refract facilitates an accurate and reproducible refraction process that is completely independent of the operator.

1. Zero bias between the two methods: average difference near to zero

2. 0.25 diopter standard deviation of error between the two methods

Page 2: Eye Refract lets you Delegate Refractions with confidence ... · subjective refraction. Spherical equivalent Optometrists (Subjective) vs Eye Refract (Eyer) EyeRefract identifies

SMALL FOOTPRINT BIG IMPACT

NEW REFRACTION STATION

Eye Refract combined with the new VX25 Acuity Chart delivers accurate and reproducible refraction results on an instrument table that’s only 43 inches long.

VISIONIX TABLET

Advanced software embedded in our wireless Eye Refract tablet guides any staff member through the 4 minute refraction. Send final prescription data to the Eye Care Professional for confirmation and sign off.

What will you do when you remove the refraction process from your consult time?

Delegating refractions with Eye Refract means new prescription information will arrive at your Exam Room PC, before your patient.

FULLY AUTOMATED, WAVEFRONT-BASED LENS ANALYZER Reads the patient’s current prescription and transfers data wirelessly to the Eye Refract station.

WHEN YOU NO LONGER REFRACT EVERY PATIENT...

NEW: VX25 SPACE SAVING CHART Designed for binocular vision testing, visual acuity and diagnostics, the VX25 space saving chart uses internal mirrors to deliver accurate results in just 2.5 feet. The

VX25 has a matte, anti-reflective screen, and a wide selection of acuity charts.

31.5 in.

For more than 100 years, Luneau staff have delivered high-quality instrumentation, service and education to eye care professionals around the world. Let us help you

implement Eye Refract in your practice!

Our Clinical Application Specialist team will partner with you to provide the best solution for your practice needs Maximize your

Uptime – our Field Service team are factory trained to ensure your instruments remain reliable.

CE courses –maximize your training and stay on top of current issues with the continuing education support we will provide in your office

Beyond hardware – we understand your practice reliesOn efficient data movement and device connectivity

Installation & training – to ensure your new instrumentation performs exactly as you wish

Page 3: Eye Refract lets you Delegate Refractions with confidence ... · subjective refraction. Spherical equivalent Optometrists (Subjective) vs Eye Refract (Eyer) EyeRefract identifies

Imagine your daily routine without refractions...How would you use that time?

LUNEAU TECHNOLOGY USA224 James St. Bensenville, IL 60106 - (800) 729-1959 - www.luneautechusa.com

Dimensions 2 VX25 space saving chart

H 25.98 in. (660 mm) x W 12.60 in. (320 mm) x D 12.79 in (325 mm) Weight 55.12 lbs (25 kg)

VX40 Wavefront analyser H 17.90 in. (455 mm) x W 8.66 in. (220 mm) x D 9.44 in. (240 mm) Weight 20 lbs (9 kg) Eye Refract Table Adjustable height side from 26.57 to 36.42 in. (675 to 925 mm) x W 42.91 in. (1090 mm) x D 18.11 in. (460 mm) Weight 38,5 Kgs (83.78 lbs) VX40 console H 32.60 in. (828 mm) x W 12.60 in. (320 mm) x D 14.13 in. (359 mm)

configuration

• Eye RefractTM

• VX25• VX40• Table VX40• Table VX25-ER

30230000-008225-0000-003014-0000-008160-8025-00 8160-0025-00

REF.

EYE REFRACTTM

Output • RS232 / USB2.0 / VGA / LAN• Embedded bluetooth / Wifi

Hardware Tablet ...............................................................AndroidChinrest ...........................................................ElectricalNear Vision Target .......................................... 250-700 mm

Mini tablet 7“Head ................................................................Autofocus, autocentering

Range Sph ..................................................................-30.00D to +27.25D Sph step ..........................................................0.125 / 0.25 / 0.50 / 1 DCyl....................................................................-6.00 to +6.00 DCyl step ...........................................................0.25 / 0.50 / 1 DOptical axis .....................................................0 to 180°Axis step .........................................................1° / 5° / 10° / 45°Prisms ..............................................................0 to 20 D

Communication

Technical Specifications

TM

Height 19.3 in (490 mm)

Width 11.4 in (290 mm)

Depth 18.5 in (470 mm)

Weight 55 lbs (25 kg)

Power100/120, 220/240 V AC, 50/60 Hz

Voltage230 V 50 / 60 Hz

1

2

3

4

4

5

3

1

5

Comfort zone

Eye Refract lets you Delegate Refractions with confidence.The Eye Refract system uses dual, Shack-Hartmann wavefront aberrometers, combined with a fully automated digital phoropter, to deliver highly accurate and reproducible refractions in less than 4 minutes. The tablet-driven process can be conducted by a staff member with limited training while still delivering consistent results.

Valid and reproducible results

Results first published in the ARVO Journal (August 2018) demonstrated Eye Refract strongly correlates with traditional refraction, showing no statistical differences between the two methodologies. Finally, Eye Refract delivered results faster as compared to conventional subjective refraction.

Spherical equivalent Optometrists (Subjective) vs Eye Refract (Eyer)

EyeRefract identifies the patient’s comfort zone by searching in 3 dimensions: Sphere, Cylinder, and Axis.

The 2018 Madrid Study demonstrates Eye Refract facilitates an accurate and reproducible refraction process that is completely independent of the operator.

1. Zero bias between the two methods: average difference near to zero

2. 0.25 diopter standard deviation of error between the two methods

Page 4: Eye Refract lets you Delegate Refractions with confidence ... · subjective refraction. Spherical equivalent Optometrists (Subjective) vs Eye Refract (Eyer) EyeRefract identifies

Imagine your daily routine without refractions...How would you use that time?

LUNEAU TECHNOLOGY USA224 James St. Bensenville, IL 60106 - (800) 729-1959 - www.luneautechusa.com

Dimensions 2 VX25 space saving chart

H 25.98 in. (660 mm) x W 12.60 in. (320 mm) x D 12.79 in (325 mm) Weight 55.12 lbs (25 kg)

VX40 Wavefront analyser H 17.90 in. (455 mm) x W 8.66 in. (220 mm) x D 9.44 in. (240 mm) Weight 20 lbs (9 kg) Eye Refract Table Adjustable height side from 26.57 to 36.42 in. (675 to 925 mm) x W 42.91 in. (1090 mm) x D 18.11 in. (460 mm) Weight 38,5 Kgs (83.78 lbs) VX40 console H 32.60 in. (828 mm) x W 12.60 in. (320 mm) x D 14.13 in. (359 mm)

configuration

• Eye RefractTM

• VX25• VX40• Table VX40• Table VX25-ER

30230000-008225-0000-003014-0000-008160-8025-00 8160-0025-00

REF.

EYE REFRACTTM

Output • RS232 / USB2.0 / VGA / LAN• Embedded bluetooth / Wifi

Hardware Tablet ...............................................................AndroidChinrest ...........................................................ElectricalNear Vision Target .......................................... 250-700 mm

Mini tablet 7“Head ................................................................Autofocus, autocentering

Range Sph ..................................................................-30.00D to +27.25D Sph step ..........................................................0.125 / 0.25 / 0.50 / 1 DCyl....................................................................-6.00 to +6.00 DCyl step ...........................................................0.25 / 0.50 / 1 DOptical axis .....................................................0 to 180°Axis step .........................................................1° / 5° / 10° / 45°Prisms ..............................................................0 to 20 D

Communication

Technical Specifications

TM

Height 19.3 in (490 mm)

Width 11.4 in (290 mm)

Depth 18.5 in (470 mm)

Weight 55 lbs (25 kg)

Power100/120, 220/240 V AC, 50/60 Hz

Voltage230 V 50 / 60 Hz

1

2

3

4

4

5

3

1

5

Comfort zone

Eye Refract lets you Delegate Refractions with confidence.The Eye Refract system uses dual, Shack-Hartmann wavefront aberrometers, combined with a fully automated digital phoropter, to deliver highly accurate and reproducible refractions in less than 4 minutes. The tablet-driven process can be conducted by a staff member with limited training while still delivering consistent results.

Valid and reproducible results

Results first published in the ARVO Journal (August 2018) demonstrated Eye Refract strongly correlates with traditional refraction, showing no statistical differences between the two methodologies. Finally, Eye Refract delivered results faster as compared to conventional subjective refraction.

Spherical equivalent Optometrists (Subjective) vs Eye Refract (Eyer)

EyeRefract identifies the patient’s comfort zone by searching in 3 dimensions: Sphere, Cylinder, and Axis.

The 2018 Madrid Study demonstrates Eye Refract facilitates an accurate and reproducible refraction process that is completely independent of the operator.

1. Zero bias between the two methods: average difference near to zero

2. 0.25 diopter standard deviation of error between the two methods