28
Eyeball Home Inspection Services Property Inspection Report Cover Page .1234 Brookhaven Ct, Fontana, CA 92336 Inspection prepared for: Don Quijote & .Micaela Quijote Date of Inspection: 8/5/2013 Time: 10:00 AM Age of Home: 2005 (8 yrs) Approx) Size: 3683 ASF (Approx) Weather: 84 Deg F (Sunny) Report #050813A; Date of last significant rain: March 8, 2013 (Approx) Inspector: Ernie Martinez Certificate #04021805 InterNachi Rancho Cucamonga, CA 91701 Phone: 909 652-0507 Email: [email protected] www.eyeballinspections.biz

Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection ServicesProperty Inspection Report

Cover Page

.1234 Brookhaven Ct, Fontana, CA 92336          Inspection prepared for: Don Quijote & .Micaela Quijote                     Date of Inspection: 8/5/2013 Time: 10:00 AM

Age of Home: 2005 (8 yrs) Approx) Size: 3683 ASF (Approx) Weather: 84 Deg F (Sunny)

Report #050813A; Date of last significant rain: March 8, 2013 (Approx)

Inspector: Ernie MartinezCertificate #04021805 InterNachiRancho Cucamonga, CA 91701

Phone: 909 652-0507Email: [email protected]

www.eyeballinspections.biz

Page 2: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services.                                              1234 Brookhaven Ct, Fontana, CA

Page 1 of 27

We appreciate the opportunity to conduct this inspection for you! Please carefully read yourentire Inspection Report. Call us after you have reviewed your report, so we can go over anyquestions you may have. Remember, when the inspection is completed and the report isdelivered, we are still available to you for any questions you may have, throughout the entireclosing process.Properties being inspected do not "Pass" or "Fail.” - The following report is based on aninspection of the visible portion of the structure; inspection may be limited by vegetation andpossessions. Depending upon the age of the property, some items like GFI outlets may notbe installed; this report will focus on safety and function, not current code. This reportidentifies specific non-code, non-cosmetic concerns that the inspector feels may need furtherinvestigation or repair. For your safety and liability purposes, we recommend that licensed contractors evaluate andrepair any critical concerns and defects. Note that this report is a snapshot in time. Werecommend that you or your representative carry out a final walk-through inspectionimmediately before closing to check the condition of the property, using this report as aguide.

Page 3: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services.                                               1234 Brookhaven Ct, Fontana, CA

Page 2 of 27

Summary of Items of ConcernSummary of Items of Concern

A Home Inspection is a non-invasive visual examination of a residential dwelling,performed for a fee, which is designed to identify observed material defects withinspecific components of said dwelling. Components may include any combination ofmechanical, structural, electrical, plumbing, or other essential systems or portions ofthe home, as identified and agreed to by the Client and Inspector, prior to theinspection process.A home inspection is intended to assist in evaluation of the overall condition of thedwelling. The inspection is based on observation of the visible and apparent conditionof the structure and its components on the date of the inspection and notthe prediction of future conditions.A home inspection will not reveal every concern that exists or ever could exist, butonly those material defects observed on the day of the inspection.A material defect is a condition with a residential real property or any portion of it thatwould have a significant adverse impact on the value of the real property or thatinvolves an unreasonable risk to people on the property. The fact that a structuralelement, system or subsystem is near, at or beyond the end of the normal useful life ofsuch a structural element, system or subsystem is not by itself a material defect.An Inspection report shall describe and identify in written format the inspectedsystems, structures, and components of the dwelling and shall identify material defectsobserved. Inspection reports may contain recommendations regarding conditionsreported or recommendations for correction, monitoring or further evaluation byprofessionals, but this is not required.On this page you will find, in RED, a brief summary of any CRITICAL concerns of the inspection, asthey relate to Safety and Function. Examples would be bare electrical wires, or active drain leaks.The complete list of items noted is found throughout the body of the report, including NormalMaintenance items. Be sure to read your entire report!For your safety and liability, we recommend that you hire only licensed contractors when having anywork done. If the living area has been remodeled or part of an addition, we recommend that youverify the permit and certificate of occupancy. This is important because our inspection does nottacitly approve, endorse, or guarantee the integrity of any work that was done without a permit, andlatent defects could exist. Depending upon your needs and those who will be on this property, items listed in the body of thereport may also be a concern for you; be sure to read your Inspection Report in its entirety.Note: If there are no comments in RED below, there were no CRITICAL system or safety concernswith this property at the time of inspection. In the main body of the report comments in BLUE indicatecertain observations made, homeowner deferred maintenance, and maintenance tipsRatings and how to view this reportThis report uses a check box style ratings system with narratives to describe the conditions of thesystems that exist in your home. We try whenever possible to include a narrative and photograph ofan item. There are many systems in a home that if functioning properly do not warrant the use of anarrative which is why we use this ratings system. You as the homeowner can view this report andbe sure that a system has been inspected, and opinion given on its condition.The following is an explanation of our ratings system: GOOD: The item(s) or system(s) inspected show no visible signs of deficiency and is in goodserviceable condition.  FAIR: Item(s) inspected in fair serviceable condition. In order to maintain the integrity of the systemrecommend continued home owner maintenance.  NEEDS REPAIR: The Integrity of the Item(s) or system(s) inspected has been compromised.

Page 4: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                1234 Brookhaven Ct, Fontana, CA

Page 3 of 27

Recommend Immediate repair(s) and attention to prevent any future safety or health hazardsSAFETY HAZARD: Problems discovered within the item(s) or system(s) inspected are aDANGER, RISK, or UNSAFE and could cause bodily injury, health problems and possiblydeath.NONE: This item was not present or viewable at the time of inspection. 

Occupied and furnished buildings - Building interior walls and floorsblocked by Personal goods and block access to visually inspectsidewall and floor areas. Any system or component not readilyaccessible should be made accessible and inspected by aprofessional prior to expiration of the inspection contingencyperiod; hidden damage or unsafe conditions may exist. Any upgradesrecommended by contractors should be complied with at time of equipmentservice.Interior FeaturesPage 9 Item: 2 Bed Condition • CLOSET DOOR MIRROR CRACKED: Bedroom #3: Closet

Mirror Cracked at lower edge. Recommend repair by aqualified contractor (Safety)• CLOSET DOOR MIRROR: Bedroom #4: Sliding ClosetMirror Door - Mirror beginning to separate from closet doorframe. Recommend review for repair by a state licensedcontractor (safety)

Page 10 Item: 3 Bath Condition • SHOWER DOORS: Upper Floor Hallway bathroom- Showerdoor Track guides not installed. Recommend repair (safety)

Page 11 Item: 4 Alarm Condition • CARBON MONOXIDE DETECTORS NOT INSTALLED:There was no visible CO (Carbon Monoxide) detector(s) on thelower floor(Visible Co detector installed on 2nd floor only). COis a deadly poisonous, colorless, odorless gas and thus impossibleto detect without a proper electronic detector. CO can be fatal ifinhaled. At a minimum, put an alarm near the sleeping roomson each level in your home.

Electric, Heat, Water Heater, Water SupplyPage 16 Item: 2 HVAC System

Condition• 3.5 Ton Unit - Electrical plastic conduit slipped loose exposingwire run. Recommend state licensed electrician repair

Exterior AreasPage 23 Item: 5 Gutters, Grading,

& SprinklerSystem

• Sprinkler control valves located at rear sidewall leaking.Recommend repair

Swimming Pool/Spa

Page 5: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services.                                                1234 Brookhaven Ct, Fontana, CA

Page 4 of 27

Page 27 Item: 1 Pool/SpaCondition

• Electrical: Sub panel at pool equipment - 15A Breaker infound in tripped "OFF" position. Recommend state licensedelectrician determine cause and repair.• Interior water lights inoperative - Spa Only - Recommendrepair• Garage side door to side yard and pool area does not self closeand latch. Recommend repair (Child safety)• Alarm audible devises not installed at rear and side area doorsthat lead to the pool water. Recommend the installation ofapproved alarms at all doors ;leading to the pool water (Childsafety)• Protective fence barrier not installed between house and poolwater areas. Recommend the installation of an approved fencebarrier to prevent a small child from entering the pool waterareas that may lead to drowning and death. (Child Safety) seeConsumer Product Safety Commission(www.CPSC.gov/swimming pool safety for additional safetyinformation)

Page 6: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services.                                               1234 Brookhaven Ct, Fontana, CA

Page 5 of 27

Details

Interior Features

1. Attendance Client present • Buyer Agent present: • Seller present

2. Home Type Single Family Home - 2 Story, Modern Contemporary

3. Occupancy Occupied - Furnished: Heavy volume of personal and household items observedlimiting access to multiple outlets, windows, walls and some rooms. • All utilitieswere on at the time of inspection - Natural Gas, Water and Electrical • Access tosome items such as: electrical outlets/receptacles, windows, wall/floor surfaces,and cabinet interiors may be restricted by furniture or personal belongings.Any such inaccessible items day of inspection are excluded from this inspectionreport.

This inspection does not include testing for radon, mold or other hazardous materials unlessspecifically requested.Plumbing is an important concern in any structure. Moisture in the air and leaks cancause mildew, wallpaper and paint to peel, and other problems. The home inspectorwill identify as many issues as possible but some problems may be undetectable dueto problems within the walls or under the flooring. Note that if in a rural location, sewer service and/or water service might be provided byprivate waste disposal system and/or well. Inspection, testing, analysis, or opinion ofcondition and function of private waste disposal systems and wells is not within thescope of a home inspection. Recommend consulting with seller concerning privatesystems and inspection, if present, by appropriate licensed professional familiar withsuch private systems. If a Septic System is on the property, pumping is generallyrecommended prior to purchase, and then every three years. Interior areas consist of bedrooms, baths, kitchen, laundry, hallways, foyer, and otheropen areas. All exposed walls, ceilings and floors will be inspected. Doors andwindows will also be investigated for damage and normal operation. Althoughexcluded from inspection requirements, we will inform you of obvious broken gas sealsin windows. Please realize that they are not always visible, due to temperature,humidity, window coverings, light source, etc. Your inspection will report visibledamage, wear and tear, and moisture problems if seen. Personal items in the structuremay prevent the inspector from viewing all areas, as the inspector will not movepersonal items.An inspection does not include the identification of, or research for, appliances andother items that may have been recalled or have had a consumer safety alert issuedabout it. Any comments made in the report are regarding well known notices and areprovided as a courtesy only. Product recalls and consumer product safety alerts areadded almost daily by the Consumer Product Safety Commission. We recommendvisiting the following Internet site if recalls are a concern to you: http://www.cpsc.gov.

Chimneys -Areas of chimney flues cannot be adequately viewed during afield inspection, which has been documented by the Chimney SafetyInstitute of America, reported in 1992: "The inner reaches of the flue are

Page 7: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services.                                               1234Brookhaven Ct, Fontana, CA

Page 6 of 27

relatively inaccessible, and it should not be expected that the distantoblique view from the top to bottom is adequate to fully document damageeven with a strong light". Therefore, because our inspection of thechimneys is limited to those areas that can be viewed without dismantlingany portion of them, and does not include the use of specializedequipment, we will not guarantee their integrity and therefore recommenda Level One (2) Fireplace Safety Inspection by a Certified Chimney Sweepor Chimney Fireplace Specialist. Also recommend an annual chimney fluecleaning as a standard preventative maintenance practice and isrecommended by the Fire Protection Association at sale or Transfer of RealEstate. Level of inspections:Level II: includes Level I visual inspection. Proper clearance fromcombustibles in accessible locations, proper construction and condition ofaccessible portions of the chimney structure and all enclosed flues, allaccessible portions the chimney exterior and interior, including areas withinaccessible attics, crawl spaces, and basements. Most Include inspection byvideo camera scanning. 

**CARBON MONOXIDE DETECTORS** The Consumer Product SafetyCommission recommends that every residence with fuel-burning (gas)appliances be equipped with a UL Listed CO alarm. CO is colorless, odorlessand Tasteless gas thus impossible to detect without a proper electronicdetector. At a minimum, put an alarm near the sleeping rooms on eachlevel in your home. Maintain all CO detectors as home ownermaintenance.Dryer Vent connector - Lack of a improperly installed vent connector orproper dryer venting to the exterior may result in excessively high humiditylevels which can damage home materials or components and mayencourage the growth of microbes such as mold. Lack of proper dryerventing can also result in the accumulation of lint in the home. Lint iscombustible and its accumulation is a potential fire hazard and a possiblehealth hazard from the inhalation of particulates. Recommend properinstallation of an Underwriter’s Laboratory (UL)-approved dryer vent pipeor duct for safety reasons. Dryer and vents should be cleaned on a plannedscheduled (Most manufactures recommend monthly) to ensure that safeconditions continue to exist. Failure to properly maintain the appliancemay potentially void any manufacture and or home warrantycoverage and can also create unsafe operating conditions.

Fire Suppression Sprinkler System Installed –The covers (and the

Page 8: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services1                                                 1234 Brookhaven Ct, Fontana, CA

Page 7 of 27

sprinkler heads) are not allowed to be painted or have any texture onthem. It can interfere with the proper operation. Any Fire SuppressionSprinkler System more than 5 years old should be professionally servicedand certified. These systems can fail from non-use. Recommend regulartesting of the system flow alarm. The Alarm is located exterior uppersidewall and should be heard by all occupants from all bedrooms. Anyextensions or alterations of your sprinkler system must be approved by thelocal fire department prior to work being done. Contact your firedepartment if and when any activation of your sprinkler system occurs(except when testing the system). Do not do anything that would hinder itsperformance such as painting or hanging objects from the sprinkler headand never turn off or disconnect the system from its sprinkler head and donot turn off the sprinkler system in the event of a fire. Let the firedepartment do it. Recommend having the system tested and certifiedby a fire sprinkler inspector specialist prior to close of escrow orcontact the local fire department for guidance.GFCI Type Receptacles - A "GFCI" is a ground fault circuit interrupter. Aground fault circuit interrupter is an inexpensive electrical device that, ifinstalled in household branch circuits, could prevent over two-thirds of theapproximately 300 electrocutions still occurring each year in and aroundthe home. Installation of the device could also prevent thousands of burnand electric shock injuries each year. The GFCI is designed to protectpeople from severe or fatal electric shocks. Because a GFCI detects groundfaults, it can also prevent some electrical fires and reduce the severity ofothers by interrupting the flow of electric current. An unintentional electricpath between a source of current and a grounded surface is referred to asa "ground-fault." Ground faults occur when current is leaking somewhere,in effect, electricity is escaping to the ground. How it leaks is veryimportant. If your body provides a path to the ground for this leakage, youcould be injured, burned, severely shocked, or electrocuted. GFC Ireceptacles recommended installed at the garage, and exterior sidewalls.Maintain all GFCI RECEPTACLES AS HOME OWNER MAINTENANCE.

Page 9: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                  1234Brookhaven Ct, Fontana, CA

Page 8 of 27

1. KitchenGood Fair Need

RepairSafetyHazard

None

X XObservations:• FOOD WASTE GARBAGE DISPOSAL: Functional. NOTE: Loud grinding noiseheard during operation. Appliance may be in the early stages of failure. Recommendreview for service and repair options by a qualified appliance technician• CABINET AREA BELOW SINKS: Functional• DRAINAGE: Drainage Draw performed and functional• PLUMBING,WATER SUPPLY SHUTOFF VALVES AND HOSES - no leaksobserved on day and time of inspection - Future leak predictions is not part of thisinspection.• SINKS & FAUCETS: Functional• STOVETOP AND OVEN - Operated & Functional.• MICROWAVE: Tested & Operated- Functional• SPRAY WAND: Operated and Functional• CEILINGS: Functional• FLOORS: Functional/no issues observed• OUTLETS: All Functional• LIGHTING: All Functional• COUNTERTOPS: Functional• GFCI OUTLETS: All Functional - Outlets within close proximity to sinks GFCIprotected• COOKING VAPOR EXHAUST SYSTEM: Operated and Functional- MaintainFilters

Voids in Sink lower Cabinet floor board and rear sidewall

Page 10: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                 1234 Brookhaven Ct, Fontana, CA

Page 9 of 27

2. Bed ConditionGood Fair Need

RepairSafetyHazard

None

X X XBedroom Locations: Bedroom #1 (main floor), Bedroom #2, Bedroom #3,Bedroom #4, Master Bedroom #1 , (Bedrooms are listed counter clockwise starting at FrontEntry Door Beginning on the main Floor)Observations:• CEILINGS: All Functional• WALLS: All Functional• FLOORS: All Functional• WINDOWS: - Dual pane sliding windows installed - All Opens/closes/ locks.• SLIDING CLOSET DOORS: Functional• ENTRY DOORS: All Functional - Hinged Wood Door, opens, closes, and locks• CEILING FAN: All Operated- All Functional• LIGHT SWITCHES: All Functional• OUTLETS: All Functional• CLOSET DOORS: All Functional• CLOSET DOOR MIRROR CRACKED: Bedroom #3: Closet Mirror Crackedat lower edge. Recommend repair by a qualified contractor (Safety)• CLOSET DOOR MIRROR: Bedroom #4: Sliding Closet Mirror Door -Mirror beginning to separate from closet door frame. Recommend review forrepair by a state licensed contractor (safety)

Bedroom #3: Closet Mirror Cracked at loweredge

Bedroom #4: Sliding Closet Mirror Door -Mirror beginning to separate from closet door

frame

Page 11: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                  1234 Brookhaven Ct, Fontana, CA

Page 10 of 27

3. Bath ConditionGood Fair Need

RepairSafetyHazard

None

X X XBathroom Locations: Main Floor Hallway full Bathroom, Upstairs Hallwayfull bathroom #1, Master Bathroom #1Observations:• DRAIN STOPS: Lower Floor Hallway bathroom sink drain stop disconnected• TOILETS: Fill Valve Recycling in hallway bathrooms- Fill valve may be in theearly stages of failure. Recommend review for repair by a state licensed plumbingcontractor when practical• PLUMBING,WATER SUPPLY SHUTOFF VALVES AND HOSES - no leaksobserved on day and time of inspection unless stated below- Future leak predictionsis not part of this inspection• DRAINAGE: Drainage Draw performed at all drains and All functional.• VENTILATION TYPE: Exhaust Fan, Window- All Functional• GFCI PROTECTION: Provided to all bathrooms. Reset in hallway bathroom• TOILET AND TANK: TYPE-GRAVITY FLUSH- All Functional• CEILINGS & WALLS: Dry wall noted- No deficiencies observed• SINK COUNTERTOP: Type- Hard resilient surfaces- Functional• SINK(S) CONDINTION: Type- Hard resilient surfaces- Functional• FAUCET FIXTURES: All Functional• CABINET AREA BELOW SINKS: Functional• SHOWER WALLS DRAINPAN AND FLOOR- TYPE: Composite Fiberglass -All Functional• BATHTUB: VINYL/COMPOSITE FIBERGLASS - All Functional

• WINDOWS : Sliding - All Opens/closes/locks• LIGHTS AND WALL SWITCHES: All Functional• CABINETS : All Functional• DOORS : Operated- All Opens/closes/locks• SHOWER DOORS: Upper Floor Hallway bathroom- Shower door Trackguides not installed. Recommend repair (safety)

Lower Floor Hallway bathroom sink drain stopdisconnected

Hallway bathrooms: Fill valve recycles

Page 12: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                   1234 Brookhaven Ct, Fontana, CA

Page 11 of 27

Upper Floor Hallway bathroom: Sliding showerdoor track guides not installed

Master Shower Door Lower edge vinyl waterseal strip not installed

4. Alarm ConditionGood Fair Need

RepairSafetyHazard

None

X X XSmoke Detector Locations: Common Areas of living space, BedroomsObservations:• SMOKE DETECTORS: Installed/Operated and Tested• MAINTENANCE TIP: Smoke detectors last 6-10 years. After that they should bereplaced• MAINTENANCE TIP: Periodic testing and changing batteries yearly to ensureproper Smoke Alarm operation is required.• MAINTENANCE TIP: CARBON MONOXIDE detectors should be replaced every5yrs or per manufacturer instructions• CARBON MONOXIDE DETECTORS NOT INSTALLED: There was novisible CO (Carbon Monoxide) detector(s) on the lower floor(Visible Codetector installed on 2nd floor only). CO is a deadly poisonous, colorless,odorless gas and thus impossible to detect without a proper electronic detector.CO can be fatal if inhaled. At a minimum, put an alarm near the sleeping roomson each level in your home.

5. Interior ElectricGood Fair Need

RepairSafetyHazard

None

XObservations:• ALL ACCESSIBLE light switches, electrical outlets, and lighting related systemsinspected and functional unless stated otherwise• CEILING LIGHTS: All Functional• CEILING FAN: All Operated-Functional• LIGHT SWITCHES: All Functional• OUTLETS: All Functional unless otherwise noted

6. Floors, Ceilings & WallsGood Fair Need

RepairSafetyHazard

None

XObservations:• CEILINGS: Bedroom #4: Dry ceiling stains observed. Stains were Tested for highlevels of moisture and tested dry day of inspection. Contact qualified contractor forservice and repair options if problem persists• CEILINGS: Functional• WALLS: Functional• FLOORS: Functional• Floor carpet stained, soiled dirty - Recommend professional cleaning.

Page 13: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                  1234 Brookhaven Ct, Fontana, CA

Page 12 of 27

Bedroom #4: Dry ceiling stains observed

7. Plumbing & LaundryGood Fair Need

RepairSafetyHazard

None

XObservations:• DRAINAGE PIPE: Type-Plastic-Drainage draw was not function checked.Appliances present and connected at time of inspection limiting access to drain.Recommend obtaining written disclosure from seller that drainage properly drains.• GAS VALVE: Could not fully inspect visually- View of Gas Valve Obscured byappliances• DRYER VENT:Could not fully inspect the dryer vent, it is obscured by Appliances• LOCATION: Garage Entry• WATER FAUCET VALVES: Installed-Functional-No Leaks Observed• MOISTURE CONTROL: Exhaust fan or window- Operated & functional• CABINETS: Type: Wood cabinets installed-Functional• FLOOR: Functional• ENTRY DOORS: All Functional• CEILINGS AND WALLS: Functional

8. DoorsGood Fair Need

RepairSafetyHazard

None

XObservations:• ENTRY AND CLOSET DOORS: All Functional - Hinged Wood Doors (opens,closes, and locks)• SLIDING PATIO DOOR(S): ( Double pane ) - All opens/closes/locks• DOOR BELL: Operated and functional

9. WindowsGood Fair Need

RepairSafetyHazard

None

XObservations:• Type: Dual Pane- All opens/closes/locks ( Representative sample taken )

10. StairwaysGood Fair Need

RepairSafetyHazard

None

XObservations:• No major system safety or function concerns noted at time of inspection.

Page 14: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                1234 Brookhaven Ct, Fontana, CA

Page 13 of 27

Electric, Heat, Water Heater, Water Supply

11. Fire Box ConditionGood Fair Need

RepairSafetyHazard

None

XFireplace Locations: Living Room, Master BedroomObservations:• HEARTH: TYPE- TILE; Fire safety requirements of 16'' to 18'' met. NOTE: MinorTile Crack at right side of hearth extension observed. No issues found• FLUE INTERIOR: Dirty- Creosote and Soot visible-Both Creaosot and Soot canfuel a chimney fire! Recommend a level 2 Fireplace Safety Inspection-Interiorsurfaces of metal updraft flue not accessible• FIREPLACE TYPE: PREFABRICATED• TYPE: GAS STARTER• CONDITION: Functional• BIFOLD GLASS PANELS INSTALLED:Functional• FLUE DAMPER GATE: Functional/Opens & Closes• WALL SWITCH: Wall switch operated and was tested and operated. Functional attime of inspection• FIREBOX SCREEN: Functional- Opens/closes

Minor Tile Crack at right side of hearth extension

Electric: Note that only actual GFCI outlets are tested and tripped. Some baths may havenon-GFCI outlets which are protected by a GFCI outlet in a remote area (garage, another bath,etc.). Confirm with owner that apparent non-GFCI outlets within 6’ of wet areas are thusprotected. Also, note that most electricians agree that smoke detectors are good for about 5years, and the breakers in your panel box have an expected life of about 20 years. Therefore,if this home was built before 1990, consider having the panel box and breakers evaluated by alicensed electrician, as an overheated breaker can result in a structural fire. If your homedoes not have a carbon monoxide detector (few do!), we recommend making that investment.Any home that has a Bulldog Pushmatic, Zinsco, Sylvania Zinsco or Federal Pacific Electricpanel should have it evaluated by a licensed electrician, as these older types of panels andbreakers have been known to overheat and cause house fires.Heat: The heating, ventilation, air conditioning and cooling system (often referred to asHVAC) is the climate control system for the structure. The goal of these systems is to keepthe occupants at a comfortable level while maintaining indoor air quality, ventilation whilekeeping maintenance costs at a minimum. The HVAC system is usually powered by electricityand natural gas, but can also be powered by other sources such as butane, oil, propane, solarpanels, or wood. The inspector will test the heating and air conditioner using the thermostator other controls. A more thorough investigation of the system, including the heat (“firebox”)exchanger, should be conducted by a licensed HVAC service person every year. Failure to do

Page 15: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                  1234 Brookhaven Ct, Fontana, CA

Page 14 of 27

so may result in carbon monoxide escaping through cracks in a heat exchanger or flue pipe,resulting in death.The inspection of the heating and cooling systems is for testing ofoperation only using normal user operating controls (Thermostat),no remaining life expectancy or warranty is implied and thisinspection is not intended to be technically exhaustive and nodismantling of any system (evaporator assemblies included) isperformed. Adequacy of system design is excluded from thisinspection report. Service life of older units is between 10 &20years and an older system or unit may be nearing the end of ituseful serviceable life. Air Conditioning systems should beinspected and certified by a (HVAC) contractor. Air Conditioningsystems require routine and periodic maintenance for peekperformance. Maintain filter(s) clean as preventative maintenanceat air return chamber areas for best system performance. Somesystems fail after taking possession (REO'S and Short sales) maytake several months to close - Recommend obtaining a homewarranty service contract that covers both furnace and AC systemsas systems have been known to fail the next day, week, or monthsafter taking possession of your home.

Plumbing systems have common components, but they are not uniform.In addition to fixtures, these components include gas pipes, water pipes,pressure regulators, pressure relief valves, shut off valves, drain pipes,vent pipes and water-heating devises. The water pressure in pipes iscommonly confused with water volume, or functional flow, but where ashigh volume may be desirable, high pressure is not. In fact, wheneverstreet pressure exceeds eighty pounds per square inch (PSI) a regulator isrequired, which typically comes factory pre-set between 40 and 65 PSI.Regardless, consumers need to understand that leaks will occur in anysystem and in particularly a system with older pipes including PVC plasticpipes or one which a regulator fails and high pressure is able to stress thewashers, diaphragms and other internal parts or components that affectfunctional flow. Predictions of future leakage and water functionalflow is not part of this inspection. Consult with sellers for a historyof any past leaks or repairs.The “AFCI” is an arc fault circuit interrupter. AFCIs are newly-developed electrical devices designed to protect against fires caused byarcing faults in the home electrical wiring. Arcing faults are one of themajor causes of these fires. When unwanted arcing occurs, it generateshigh temperatures that can ignite nearby combustibles such as wood,paper, and carpets. Arcing faults often occur in damaged or deterioratedwires and cords. Some causes of damaged and deteriorated wiring includepuncturing of wire insulation from picture hanging or cable staples, poorlyinstalled outlets or switches, cords caught in doors or under furniture,furniture pushed against plugs in an outlet, natural aging, and cord

Page 16: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                   1234 Brookhaven Ct, Fontana, CA

Page 15 of 27

exposure to heat vents and sunlight. Maintain all AFCI breakers ashome owner maintenance.Water Heater - Flammable vapor ignition (FVI) typically occurs whencontainers of volatile liquids, such as gasoline, are left uncapped or arespilled. These vapors travel readily undetected. Should they come incontact with any open flame or spark such as from a gas burning appliance,they can ignite causing fires and injuries. Current gas hot water heaterscontain special flammable vapor ignition resistant (FVIR) technology thatprevents the ignition of flammable vapors, such as spilled gasoline, outsidethe unit. All gas hot water heaters sold since July 1, 2003, must have thisFVIR technology. Maintain filter at base of water heater clean of debris ashome owner maintenance.1. Electrical Panel ConditionGood Fair Need

RepairSafetyHazard

None

XMaterials: Main service panel and meter location: exterior sidewall of garage,Square D - All In One, 200A Rated panel - Bonded/Grounded panel - Groundrod location below main service panel interior garage sidewall, Bus bars andHot Plate, Underground Service, Main disconnect cut off breaker(s): 200A,Branch circuit protection: Adequate, Branch circuit wiring type: Copper,AluminumMaterials: Sub Panel -Not located - Personal goods in garage sidewallsObservations:• No major system safety or function concerns noted at time of inspection at mainpanel box.• Maintenance Tip: AFCI type breakers observed in main service panel - maintain allAFCI as Home Owner maintenance - Function check breakers every other month aspreventative maintenance,.

AFCI circuit breakers

Page 17: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                   1234Brookhaven Ct, Fontana, CA

Page 16 of 27

2. HVAC System ConditionGood Fair Need

RepairSafetyHazard

None

X XInformation: Furnace - Mfg: Comfortmaker - natural gas - location: Atticspace - Horizontal type - Non recallable item. x 2 separate units, AirConditioning system - Mfg: Comfortmaker - Split type - R-22 refrigerant - 1 - 4ton unit and 1 - 3.5 Ton Unit; Evaporator assemblies located at furnace air outchambers; Condenser assemblies located exterior rear sidewallObservations:• Thermostat(s) - A/C & Furnaces responded to thermostat. Warm air flowed out allair supply registers during the furnace functional checks and very cool air flowed outall air supply registers during the AC system checks.• Return air motors and fan assemblies operated• Furnace cabinet - Panels and general installation - Good• Air conditioning condenser assemblie(s) located exterior sidewall on concretedeck. Operated and functional• Electrical disconnects installed and with line of sight - mounted at sidewalls next tounits. Cover plate protection installed.• Refrigerant lines insulated - maintain insulation to prevent line sweating, higherenergy operating costs and to prevent premature damage to systems. (Preventativemaintenance)• COOLING FIN DAMAGE: AC condenser assembly located at exterior rearsidewall - Section of cooling coil fins meshed together and may affect coolingefficiency of system increasing energy costs. During operation cooling systemnormally operated and cooled.• Insulation wrap missing from plumbing and electrical wiring at sidewall entrypoint. Recommend insulation wrap to prevent water intrusion and damage.(Preventative maintenance)• 3.5 Ton Unit - Electrical plastic conduit slipped loose exposing wire run.Recommend state licensed electrician repair

Low voltage wiring conduit loose exposingwire run

AC condenser equipment feed through atsidewall not covered

Page 18: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                  1234 Brookhaven Ct, Fontana, CA

Page 17 of 27

Condenser cooling fins slight damage

3. Water Heater ConditionGood Fair Need

RepairSafetyHazard

None

XObservations:• Location: Garage• Mounted on wood framed platform 18 inches above the floor.• Type: Water storage tank; Mfg: A.O. Smith; 50 Us Gals; 40,000 BTU - 2005• Updraft hood and vent connector• Water hoses insulated - Metal flex connector lines; Manual shut off valve installed.• TPRV (Temperature Pressure Relief Valve) and overboard drain tube - Installed• Gas plumbing, Shut off valve and connector installed• Burner and cover plates installed. FVIR Technology installed.• Thermostat - Mid warm/hot position• Earthquake straps - Installed• Metal Drain Pan: Not Installed. The Drain pan acts as a secondary containment forwater spillage. Recommend the installation of an approved drain pan• Hot water observed at all faucet valves• Fuel Supply: Type: Natural Gas

4. Plumbing System ConditionGood Fair Need

RepairSafetyHazard

None

X XMaterials: Water Meter Location: Front public walkway - Below grade - Creepmeter check performed. • Water Supply Plumbing: Type: Copper whereviewable • Water supply (static) pressure: 65 psi • Water Dynamic flow dropPsi: to 0 psi • Water Distribution Plumbing: Type:Copper - Viewable andaccessible areas only • Water Supply Shut Of Valve: Location: Front exteriorsidewall • Water Supply Shut Of Valve: Location: Exterior sidewall • WaterSupply Regulating Valve: Installed at exterior sidewall • Exterior hose faucetvalves: Quantity: 2 - Front and rear sidewalls • Exterior hose faucet valves:Quantity: 2 - Front and rear sidewallsObservations:• Front exterior hose faucet valve leaks at handle valve stem. Recommendrepair/replacement of valve.• Natural gas meter and shut off valve: Location: Front exterior sidewall• Gas plumbing line at sidewall entry point has void. Recommend sealing to preventvermin and water intrusion.

Page 19: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                               1234 Brookhaven Ct, Fontana, CA

Page 18 of 27

Garage, Crawlspace, Attic, & Foundation

Front sidewall spigot hose valve leaks Gas plumbing voids at sidewall entry point

5. Condition/Fire Sprinkler SystemGood Fair Need

RepairSafetyHazard

None

XObservations:• Fire Suppression Sprinkler System Installed - Riser, gage and shut off valve locatedat interior garage sidewall. Inspectors Test valve located at exterior sidewall.Recommend Water Flow, Alarm test and Certification. Systems have been known tofail from non use. Future predictions of the fire sprinkler system performance and/orfailure is beyond the scope of this inspection• Fire sprinklers observed at garage, attic spaces and and interior living spaces upperand lower floor ceilings.

Note that minor settlement or “hairline” cracks in garage or basement slabs are not noted in aninspection, as they are normal to properties of any age. They should, however, be monitored forexpansion and sealed as necessary. Residential inspections only include garages and carports thatare physically attached to the house. They are not considered habitable, and conditions are reportedaccordingly.Inspectors are not required to enter any crawlspace areas that are not readily accessible, less than36” clearance, wet (electrical shock hazard), or where entry could cause damage or pose a hazard tothe inspector.We recommend that all attic hatches have a batt of fiberglass insulation installed over them, and thatthe hatch be sealed shut with latex caulk. This will keep warm moist air from entering the attic, whichmay cause condensation or even mold. Note that every attic has mold; mold is everywhere. Someattics have some minor visible mold. This is often a result of the building process, when materials getwet during construction. If there is extensive mold, or mold that appears to have grown due to poormaintenance conditions, we will report it to you, the client. If the hatch is sealed shut when we go toinspect the attic, it can only be unsealed by the owner or their representative, as our insuranceprohibits us from performing any destructive testing or entry. In accordance with industry andinsurance standards, we will not attempt to enter an attic that has no permanently installed steps orpull-down stairs; less than thirty-six inches of headroom; does not have a standard floor designed fornormal walking; walking, in the inspector’s opinion, may compromise the ceiling below; is restrictedby ducts, or in which the insulation obscures the joists and thereby makes mobility hazardous, inwhich case we will inspect the attic as best we can from the access point, with no comments orevaluations of areas not readily viewed from the hatch area. ATTIC INSPECTIONS - Observations are made to reveal roof leakage and structuraldamage. However, this inspection does not guarantee against roof leakage.Conditions concealed underneath attic insulation and in smaller attic areas and areas

Page 20: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                 1234 Brookhaven Ct, Fontana, CA

Page 19 of 27

that are not accessible or have limited access are excluded. Attic Roof Ventilation -Attic ventilation is an important part of roofing. Proper attic ventilation extends the lifeof a roof and reduces problems because it minimizes the temperature differentialbetween the attic and the air outside. Proper ventilation will remove moisture and heatfrom the attic. Trapped heat and moisture can raise energy costs and damage roofsystem structural components as well personal items located inside the attic wheretemperatures can easily reach 150F (65C) and if the health &safety of the inspector isjeopardized, the attic inspection may terminate early.1. GarageGood Fair Need

RepairSafetyHazard

None

XObservations:• GARAGE DOOR(s) - One (1) 7 x 16 approx pull up sectional door

• GARAGE DOOR(s) - One (1) 7 x 8 approx pull up sectional door - No autoactuator assembly provided - manual operated only.

• Attached to main structure of house• AUTO DOOR OPERATER: TYPE: Track/Screw Drive - Garage vehicle metalentry door(s) Auto operators installed for the 7 x 16 Roll Up door only - Operatednormally• LASER EYE AND MECHANICAL REVERSE FUNCTION: Installed at lowertrack areas - Tested and functional 7 x 16 door only• EXTERIOR SIDE DOOR:Type- Wood hinged door - opens/closes/locks-Functional• FLOORS: Concrete - Functional• INTERIOR FRAMING: Wood Framed - Drywall covered - anchoring not viewable-appears functional• FIRE DOOR: Entry Door solid appears to be fire rated and self closes. Meets thestandard fire rated thickness of 1 3/8"• ELECTRICAL- LIGHTING & OUTLETS: Lighting functional. Receptacles GFCIprotected and tested.• Personal goods and equipment block access to sidewalls and floors. Only viewableand accessible areas are inspected. Recommend professional inspection prior totaking possession of property: Hidden safety or hazardous conditions may exist.

2. AtticGood Fair Need

RepairSafetyHazard

None

XObservations:• ENTRY LOCATION: SCUDDLE ACCESS DOOR AT- Master bedroom closet• AVERAGE INSULATION DEPTH: 8 to 10 inches of blown in fiber evenly spread- R-Value approx 38 - Good for year structure built.• ROOF DECK: OSB (Oriented Strand Board) - No water intrusion observed• LIGHTING: Provided• ELECTRICAL: Functional- Viewable at accessible locations• PLUMBING: Functional- Viewable at accessible locations• VENTILATION: Roof deck screened roof grills - Upper and lower roof deck• STORAGE CAPACITY: Minimal

3. Foundation TypeGood Fair Need

RepairSafetyHazard

None

XObservations:• Concrete slab on grade.

Page 21: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                  1234 Brookhaven Ct, Fontana, CA

Page 20 of 27

Exterior Areas

4. Foundation ConditionGood Fair Need

RepairSafetyHazard

None

XObservations:• No deficiencies were observed at the visible portions of the structural foundationbase of the home. Interior foundation top surfaces covered by floor coverings.Interior top surfaces are walked on and scanned by the eye to detect abnormalfoundation conditions. No abnormal foundation conditions observed on day and timeof inspection.

5. Crawlspace ConditionGood Fair Need

RepairSafetyHazard

None

X

As with all areas of the house, we recommend that you carefully examine the roofimmediately prior to closing the deal. Note that walking on a roof voids somemanufacturer’s warranties. Adequate attic ventilation, solar / wind exposure, andorganic debris all affect the life expectancy of a roof (see www.gaf.com for roof info). Always ask the seller about the age and history of the roof. On any home that is over3 years old, experts recommend that you obtain a roof certification from an establishedlocal roofing company to determine its serviceability and the number of layers on theroof. We certainly recommend this for any roof over 5 years of age. Metal roofs insnow areas often do not have gutters and downspouts, as there is a concern thatsnow or ice cascading off the roof may tear gutters from the house. Likewise, beadvised that such cascading may cause personal injury or even death. If this househas a metal roof, consult with qualified roofers or contractors regarding the advisabilityof installing a damming feature which may limit the size and amount of snow / icesliding from the roof. Grading and drainage are probably the most significant aspects of a property, simplybecause of the direct and indirect damage that moisture can have on structures. Moredamage has probably resulted from moisture and expansive soils than from mostnatural disasters. Also, there should be gutters and downspouts with splash blocksthat discharge away from the building. We have discovered evidence of moistureintrusion inside structures when it was raining that would not have been apparentotherwise. In addition, we recommend that downspouts do not terminate over pavedareas such as walks or driveways, as they can contribute to icy slip and fall hazards inwinter.Minor settlement or “hairline” cracks in drives, walks or even foundations are arenormal to properties of any age. They should, however, be monitored for expansionand sealed as necessary. Note that any siding, but especially composition or hardboard siding must be closelymonitored. A classic example is the older style Louisiana Pacific siding, where thefailure and deterioration provided grounds for a class action lawsuit. Even moderncomposition siding and, especially, trim, is particularly vulnerable to moisture damage.All seams be must remain sealed and paint must be applied periodically (especiallythe lower courses at ground level). It is imperative that continued moisture be keptfrom it, especially from sprinklers, rain splash back or wet grass. Swelling anddeterioration may otherwise result. Vegetation too close to the home can contribute to damage through root damage tothe foundation, branches abrading the roof and siding, and leaves providing a pathwayfor moisture and insects into the home.Although rails are not required around drop-offs less than 30”, consider your ownpersonal needs and those of your family and guests. By today’s standards, spindlesat decks and steps should be spaced no more than 4” apart for the safety of children.

Page 22: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                  1234 Brookhaven Ct, Fontana, CA

Page 21 of 27

Open window wells should have either grates or, preferably, a weatherproof shieldinstalled over them. This will keep rain and snow from building up inside the well andpossibly leaking into the home, as well as minimizing your liability from children andnon-residents falling inside them. An egress ladder should also be installed within thewell, especially at below-grade bedrooms. Wood Insect Boring Inspection– As per California Business and ProfessionalCode Section: 8500-8519.5 “No persons shall perform and inspect for wooddestroying infestations and infections unless licensed by the “California State PestControl Board.” The pest control inspection is to include unless otherwise specified,all information regarding the foundation walls, substructure, footings, patios and steps,porches, attic spaces, abutments, air vents, roof framing, that includes the eaves,fascia, rafters, exposed sheathing, exposed timbers, ceiling joists, and attic walls,and/or other parts subject to attack by wood destroying pests or organisms. Conditionsusually deemed likely to lead to infection and/or infestation, such as earth to woodcontacts, faulty grade levels, evidence of roof leaks, excessive cellulose debris,moisture conditions, and insufficient ventilation are to be reported. No inspection forwood destroying pests is made by this Home Inspection Company to detectpast or present Wood insect boring activity including rot and decay. Wood isinspected for deterioration only. Only a State Licensed termite (WDI-Wood DestroyingInsect)) inspection company can call out rot and WDI insect activity. If viewable wooddeterioration will be noted and referred to have a State Licensed Termite InspectionCompany evaluate and treat/repair as needed.  

ROOF Inspections - Every roof is as good only as good as theweatherproof membrane beneath it, which is concealed and cannot be seanwithout removing the roofing material and is equally true of almost all roofcoverings. However, what remains to be true of all roofs is that, whereastheir condition can be evaluated, it is virtually impossible for anyone todetect a leak or leaks except as it is occurring or by specific water tests,which are beyond the scope of this inspection and disclaimed. Significantrainfall on the day of the inspection is a good water test to detect waterintrusion into the attic and living spaces. Maintain sealant at all roof ventpipe, chimney, skylight, edge flashings and any and all other penetrationsas preventative maintenance to prevent interior water leakage.Recommend annual and semi annual roof inspection by state licensed roofcontractor, C-39 Classification as preventative maintenance to preventwater intrusion and damage.

Rain Gutters and Downspouts. While gutters and downspouts are notintegral components of a building and carry little weight in establishing thestructural condition of a building, they still perform an important function;Degenerated gutters and downspouts, or the lack of gutters anddownspouts can have a negative impact on other building components byallowing water run-off to penetrate or cause damage to building surfaces:Fascia boards, siding and foundations systems. Maintain all rain guttertroughs clean for complete water drainage from the roof.

Lot grading and drainage have a significant impact on the building,

Page 23: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                1234 Brookhaven Ct, Fontana, CA

Page 22 of 27

simply because of the direct and indirect damage that moisture can haveon the foundation and sidewalls. It is very important, therefore, thatsurface runoff water be adequately diverted away from the home. Lotgrading should slope away and fall a minimum of one (1) inch every footfor a distance of six (6) feet around the perimeter of the building.1. RoofGood Fair Need

RepairSafetyHazard

None

XMaterials: ROOF VIEWED BY: HIGH POWERED BINOCULARS FROMGROUND AND ON LADDER FROM ROOF EDGE • ROOF COVERINGTYPE: Concrete/clay spanish roll tiles • Roof Design Structure: Main Roof:Gable/HIP • Safety Height restrictions prohibit traversing the roof upper deck.Lower deck viewed at edge with the aid of a ladder. Front & rear span areasviewed from ground with high powered binoculars. • Roof vent pipes, Rainboots and other roof deck penetrations. • Valley gutters and roof decktransitions • Roof spans, HIP rafters and Ridgeline • Roof deck rafter overhangand fascia boardsObservations:• ROOF CONDITION: All tiles in place - all deck spans upper and lower decks,Edge and ridge caps. Normal wear observed approximate remaining service life 42years (approx)• VENT PIPE PENETRATIONS: Metal and ABS Plastic Pipes- Sealed• VALLEY DECK TRANSITIONS: Functional• Valley metal flashings: Functional• Roof vent grills installed all deck levels• MAINTENANE TIP: Recommend semi annual and annual roof inspection by C-39Roof Contractor as preventative maintenance to prevent water intrusion and damage.Maintain all roof penetrations, pipes, and chimneys sealed to prevent water intrusionand damage.

2. ChimneyGood Fair Need

RepairSafetyHazard

None

XObservations:• TYPE FACTORY BUILT: Wood Framed Chase - Stucco coated exterior finish• RAIN CAP TYPE: Metal Rain Cap/Plate; Has fire screen and protective plates• FLUE TERMINATION: TYPE: Metal Shroud• FLASHINGS: Functional-Sealed

3. Wall SystemGood Fair Need

RepairSafetyHazard

None

XMaterials: Construction Type: Wood Frame • West • East • South • NorthObservations:• No abnormal defects observed

4. Siding ConditionGood Fair Need

RepairSafetyHazard

None

XInformation: Stucco Siding • Exterior windows and screens • Foam trimaround window and door areas • Window wood shutters • Foam/wood trimaround window and door areasObservations:• No major system safety or function concerns noted at time of inspection.

Page 24: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                 1234 Brookhaven Ct, Fontana, CA

Page 23 of 27

5. Gutters, Grading, & Sprinkler SystemGood Fair Need

RepairSafetyHazard

None

X XInformation: Galvanized Gutters • Irrigation Sprinkler system installed atfront and rear area yards. • Sprinkler auto control box located: Garage interiorand exterior sidewallsObservations:• GRADING: Flat• DRAINAGE: Water appears to drain water away from foundation. No standingwater observed at perimeter areas of the foundation base of the structure.• Rain gutter system installed - Downspout lower extension end elbows missing atseveral sidewall locations. Recommend the installation of extension elbows to divertwater away from sidewalls and foundation systems to prevent water intrusion anddamage.• Sprinkler heads installed too close to sidewall system - Recommend relocating orinstalling a irrigation hose drip system at all areas spraying water onto the siding toprevent damage and water intrusion.• Gutter downspout extension elbows crushed at several locations. Recommendrepair to allow for proper water drainage. (preventative maintenance)• Maintenance Tip: Keep gutters cleared of organic debris to prevent downspoutsfrom being clogged causing overflow at gutters, ensure that all downspouts haveextensions/splash blocks to carry water away from the foundation.• Maintenance Tip: Keep gutters cleared of organic debris to prevent downspoutsfrom being clogged causing overflow at gutters, ensure that all downspouts haveextensions/splash blocks to carry water away from the foundation.• Sprinkler control valves located at rear sidewall leaking. Recommend repair

Rain gutter downspout end elbows notinstalled several locations

Sprinkler spray heads too close to sidewallsystems

Page 25: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                   1234 Brookhaven Ct, Fontana, CA

Page 24 of 27

Gutter downspout end elbows crushed severallocations

Rear sidewall sprinkler control valves leak

6. Drives & Walks ConditionGood Fair Need

RepairSafetyHazard

None

XInformation: Concrete driveway • Concrete sidewalk.Observations:• No major system safety or function concerns noted at time of inspection.

7. Vegetation ConditionGood Fair Need

RepairSafetyHazard

None

XObservations:• Trees observed growing in close proximity of building foundation, siding and roofsystems that may cause damage. Recommend maintaining clearance from siding toprevent damage, (Preventative maintenance)

Bushes growing contacting sidewall system

8. Patio Covers, Balcony, Decks, & Steps ConditionGood Fair Need

RepairSafetyHazard

None

XObservations:• Front entry deck - Concrete• Patio deck - Rear - Concrete• Patio cover - Type: Aluma-wood - Anchored - No abnormal conditions observed

Page 26: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                  1234 Brookhaven Ct, Fontana, CA

Page 25 of 27

Swimming Pool/Spa

9. Fencing, Gates, Block Walls ConditionGood Fair Need

RepairSafetyHazard

None

XObservations:• Block walls perimeter of property - No abnormal conditions observed.• Gates: Single metal gate at side entry area.• Retaining wall (block) observed rear yard

10. Exterior Electrical ConditionGood Fair Need

RepairSafetyHazard

None

XObservations:• OUTLETS: GFCI protected• Exterior lights - Operated• Front garage exterior sidewall light lamp missing. Recommend the installation oflamp bulb and function check light.

Chlorine generators can help fight against waterline scum build-up. Theycreate a better, healthier swimming experience for most people. It isn'tnecessary to handle or buy chlorine, and, if the unit is functioning correctly,chlorine residual will always be present in the pool, eliminating algae. Thismakes it nearly impossible to get burning red eyes from chloramines, whichis usually the culprit. Even with a chlorine generator, you still mustmaintain your pool. You still must maintain correct water balance, and youmust maintain the unit itself. The best pool will have 24/7 circulation,correct hydraulic design with an in-floor cleaning system for bottom upcleaning and circulation, a quality ozone system, and a chlorine generatorfor sanitizer residual. If you do not maintain a chlorine generator ormaintain your pool chemistry you can destroy your pool's interior finish,decking and pool equipment. Salt-water pools are great but they needcare.

Swimming pool inspections - The pool and spa is a visual inspection andequipment operation check only. The inspection is a limited non-invasiveand non intrusive inspection. The inspection is general in scope and natureand is chiefly concerned only with the readily accessible electro-mechanicalsystems. Inline plumbing pressure checks for leakage and water chemicalbalance checks are not part of this inspection. Recommend consulting witha professional pool company if this is desired to be done. Note on Poolsafety: Pool/Screen enclosures - Recommend audible alarms installed atrear doors that enter into the pool area. As an alternative to not havingaudible warning alarms installed at door locations - pool safety covers arerecommended installed. A power safety cover should meet therequirements of ASTM pool cover installation standard which addresseslabeling requirements and performance. ASTM requires that the coverwithstand the weight of two (2) adults and a child to allow a rescue shouldan individual fall onto the cover. A power safety cover is a motorized

Page 27: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                1234 Brookhaven Ct, Fontana, CA

Page 26 of 27

powered barrier that can be placed over the water area. When the powersafety cover is properly over the pool, it provides a high level of safety forchildren under 5 years old by inhibiting their access to the water. Also asan alternative to a pool safety cover, a fence barrier installed around thepool exterior or between the patio framing members is recommended. Forinformation on pool safety visit Consumer Product Safety Commission(CPSC) www.cpsc/pool/safety).1. Pool/Spa ConditionGood Fair Need

RepairSafetyHazard

None

X X X XMaterials: Pool/Spa Decking • Deck Seal • Interior shell: Type: GunitePlaster/Cement • Coping and Tile • Water Sight Level • Pool/Spa Drain Covers:Type: Domed anti vortex type • Pool Filler Line: Auto fill system • Diving Board• Electrical: Equipment breaker: At Main Panel - Adequate protection •Electrical: Sub panel CB protection - Adequate • Pool/Spa Lights •Heater/Furnace • Filter Bowl/Housing and pressure: Normal • Plumbing •Timers • Fencing • Pool/Spa Access - Doors/gates • Alarms - Doors • Pool Sweep• Skimmer return and flapper valve • Water fall feature • Pump and othermetal parts bonded/grounded • Electrical: Light & Other Breakers at subPanel: 15 & 20A • Pump(s): Main pool and secondary boost • Water fall/cascade(Spa) feature • Salt Water SystemObservations:• Deck seal deteriorated - Has voids - Recommend sealing voids.• Diving board loose at base attach area - Corroded. Service recommended to removecorrosion. (Preventative maintenance)• Electrical: Sub panel at pool equipment: Pool Light circuit GFCI protected andtested.• Pool/Spa furnace/heater operated - heated spa water to mid warm during operation -spa water might take up to 2 hours to fully attain desired selected water temperature.• Auto chlorinated and Salt water system installed. Maintain salt and chlorine levelsto prevent damage to system• At Pool equipment - Pool and spa water control valves - auto and manual systemsoperated• Water Skimmer return - No skimmer water return observed at skimmer return.Weir gate installed. Recommend service.• SPA Jet push buttons at sidewall did not actuate jets. Recommend service.• Concrete deck at spa step - crack minor crack observed. Recommend sealing toprevent water intrusion and damage. (Preventative maintenance)• Electrical: Sub panel at pool equipment - 15A Breaker in found in tripped"OFF" position. Recommend state licensed electrician determine cause andrepair.• Interior water lights inoperative - Spa Only - Recommend repair• Garage side door to side yard and pool area does not self close and latch.Recommend repair (Child safety)• Alarm audible devises not installed at rear and side area doors that lead to thepool water. Recommend the installation of approved alarms at all doors;leading to the pool water (Child safety)• Protective fence barrier not installed between house and pool water areas.Recommend the installation of an approved fence barrier to prevent a smallchild from entering the pool water areas that may lead to drowning and death.(Child Safety) see Consumer Product Safety Commission(www.CPSC.gov/swimming pool safety for additional safety information)

Page 28: Eyeball Home Inspection Serviceseyeballhomeinspection.com/wp-content/uploads/2013/... · Maintenance items. Be sure to read your entire report! For your safety and liability, we recommend

Eyeball Home Inspection Services                                                 1234 Brookhaven Ct, Fontana, CA

Page 27 of 27

Diving board mount supports corroded Deck step cracked

Sub panel 20A breaker tripped in "OFF" Deck seal voids