6
2.0 Octopus EyeSuite Perimetry Progression Analysis Structure Function Correlation Connectivity Progression Analysis Structure Function Analysis Most Advanced Progression Analysis. Perimeters

EyeSuite Perimetry Specifications Your reliable partner ... EyeSuite™ HFA style ... or the HFA style printout

Embed Size (px)

Citation preview

Page 1: EyeSuite Perimetry Specifications Your reliable partner ... EyeSuite™ HFA style ... or the HFA style printout

2.0

From the technology leader in perimetry

HAAG-STREIT AGGartenstadtstrasse 103098 Koeniz, SwitzerlandPhone +41 31 978 01 11Fax +41 31 978 02 82 [email protected]

Octopus EyeSuite Perimetry

2

Your reliable partner.

Progression AnalysisStructure Function CorrelationConnectivity

Progression Analysis Structure Function Analysis

EyeSuite® Perimetry Specifications

Basic Functions

Specifications are subject to change without notice

Import of Peritrend and Peridata filesImport of Goldmann GKP filesSingle/Bilateral field display / printoutConfigurable 4-in-1 display / printoutConfigurable series printoutMovie display functionOctopus style display mode ("+" signs)Peridata style display mode (all numbers)HFA style display / single field printoutColor and monochrome printout modesGoldmann Kinetic display / printout

Enhanced FunctionsStatistcial export of static and kinetic perimetry

Cluster and Polar AnalysisPolar GraphCluster AnalysisCluster Trend AnalysisPolar Trend Analysis

Progression RateTrend Analysis on MD, sLV(PSD), DD, LDCalculation of progression rate / significance

ConnectivityOctopus 1-2-3 / HFA 7xx/7xxi serial interfaceOctopus 3xx serial and ethernet interfaceOctopus 101 Peritrend interface for SAPElectronic Medical Record interfaceImport of programs: G, G1, G1X, G2M, M1X, M2, ST, 07, 32, LVC, LVPN1, D1, ET (Mon./Bin.), BG, FG, BT10-2, 24-2, 30-2, 60-4, Nasal step, Sup 36, 64C-40,-76,-80,-Armaly, FF-120, -135, -246, -Arm.Full network supportWindows Terminal Server supportFree viewing stations

PROLITE ADVANCED

Most Advanced Progression Analysis.

Perimeters

HAAG-STREIT USA INC. 3535 Kings Mills Rd Mason, Ohio 45040 Phone +1-513-336-7255 Fax +1-513-336-7260 Toll Free +1-800-787-5426 www.haag-streit-usa.com

HAAG-STREIT UK Ltd Edinburgh Way Harlow Essex CM20 2TT Phone +44-1279 414969 Fax +44-1279 635232 www.haag-streit-uk.com

© H

AAG

-STR

EIT

AG, 3

098

Koen

iz, S

witz

erla

nd

HS-D

oc. n

o. 1

511.

7220

291.

0202

0 – 2

013 –

01

Page 2: EyeSuite Perimetry Specifications Your reliable partner ... EyeSuite™ HFA style ... or the HFA style printout

2.0

From the technology leader in perimetry

HAAG-STREIT AGGartenstadtstrasse 103098 Koeniz, SwitzerlandPhone +41 31 978 01 11Fax +41 31 978 02 82 [email protected]

Octopus EyeSuite Perimetry

2

Your reliable partner.

Progression AnalysisStructure Function CorrelationConnectivity

Progression Analysis Structure Function Analysis

EyeSuite® Perimetry Specifications

Basic Functions

Specifications are subject to change without notice

Import of Peritrend and Peridata filesImport of Goldmann GKP filesSingle/Bilateral field display / printoutConfigurable 4-in-1 display / printoutConfigurable series printoutMovie display functionOctopus style display mode ("+" signs)Peridata style display mode (all numbers)HFA style display / single field printoutColor and monochrome printout modesGoldmann Kinetic display / printout

Enhanced FunctionsStatistcial export of static and kinetic perimetry

Cluster and Polar AnalysisPolar GraphCluster AnalysisCluster Trend AnalysisPolar Trend Analysis

Progression RateTrend Analysis on MD, sLV(PSD), DD, LDCalculation of progression rate / significance

ConnectivityOctopus 1-2-3 / HFA 7xx/7xxi serial interfaceOctopus 3xx serial and ethernet interfaceOctopus 101 Peritrend interface for SAPElectronic Medical Record interfaceImport of programs: G, G1, G1X, G2M, M1X, M2, ST, 07, 32, LVC, LVPN1, D1, ET (Mon./Bin.), BG, FG, BT10-2, 24-2, 30-2, 60-4, Nasal step, Sup 36, 64C-40,-76,-80,-Armaly, FF-120, -135, -246, -Arm.Full network supportWindows Terminal Server supportFree viewing stations

PROLITE ADVANCED

Most Advanced Progression Analysis.

Perimeters

HAAG-STREIT USA INC. 3535 Kings Mills Rd Mason, Ohio 45040 Phone +1-513-336-7255 Fax +1-513-336-7260 Toll Free +1-800-787-5426 www.haag-streit-usa.com

HAAG-STREIT UK Ltd Edinburgh Way Harlow Essex CM20 2TT Phone +44-1279 414969 Fax +44-1279 635232 www.haag-streit-uk.com

© H

AAG

-STR

EIT

AG, 3

098

Koen

iz, S

witz

erla

nd

HS-D

oc. n

o. 1

511.

7220

291.

0202

0 – 2

013 –

01

Page 3: EyeSuite Perimetry Specifications Your reliable partner ... EyeSuite™ HFA style ... or the HFA style printout

9

10

10 22125

5

5 5

8

19

19

18 12

7

7

7

614

18

28

26

+

+

+

5.9

8.1

12.6

21.7

6.5

+

+

5.5

+ +

++

+

+

+

++

++

+

+

+

++

+

+

+

++

++

++

+

+

+ +

++

+

+

++

++

9

5

7

7

10 8

5

5

12

19

18

614

12

18

10

7

2826

19

22

5

102030S

I

N T

2000

0

15

252001 2002 2003 2004 2005

MD Mean defect (OS)

Slope dB yr p2.0 / ( <0.5%)

G 18.12.2003

1/17(+), 0/17(-)

G 29.06.2004

0/16(+), 2/16(-)

G 24.01.2005

1/18(+), 1/18(-)

3 4 5

Intelligent cluster analysisCluster analysis combines high sensitivity with good specificity.

• Testlocationsaregrouped(clustered)alongnervefiberbundles tobetteranalyzechangesincrucialareaslikethenasalstepor themacula• Eliminatestimeconsumingmethodofcountingisolatedpoints• Combinedprobability/deviationgraphhighlightspathologic regions

Polar Graph - combining structure and functionCombining the results of both structure and function is key in obtaining a comprehensive assessmentfor the onset and Progression of Glaucoma. With the Octopus Polar Graph the nerve fiber bundles that are in dan-ger or defective are easily identified.

Trend analysisPerform trend analysis for Octopus Polar Graphs and Cluster Analysis right on your computer screen with specific and comprehensive graphs.

• Multiplespecificoverviewsareavailableattheclickofamouse• Movie-likeanimationtodemonstrateresultstoyourpatient• Cluster-andPointwiseLinearRegressionAnalysis–PLRA

Localdefectsarerepresentedasredlinesandprojectedalongthenervefiberstotheopticdisc.Theprojecteddefectsareverticallymirroredandscaledwithringsfor10,20and30dBdeviation.TheOctopusPolarGraphallowsfordirectcomparisonwithstructuralfindings.

Overview at a glanceVisual Field Analysis starts with getting an over-view.

• OctopusEyeSuiteprovidesacompleteoverviewofall examinationstoshowandanalysechanges• Performsbilateralviewingtogetthecompletepicture• Quicklyselect/deselectexaminationswithasimpleclickofthe mouse

Easy Progression analysisA red icon will display when significant worsening occurs.

• CalculationoftheProgressionrateindBperyearincludingthe probabilitylevelasrecommendedbytheInternationalGlaucoma Societies • Areasfornormalrange(greyband),impairedvision(15dB) andlegalblindness(25dB)provideorientation

Intuitive colour codesSave time by immediately identifying levels of change.A red icon will always display significant wor-sening.

• Aredtrianglethatpointsdownidentifiessignificantworsening• Ayellowdiamondsignalsincreasedfluctuation–asignfor upcomingchanges• A green triangle signals recovery

Discussfindingswithinyourteam.Continuededucationandexchangeofideasaresupportedby Haag-StreitOctopus.

ConnectivityDon’t lose your Data!

Importexistingvisualfieldsfromdifferentperimetersandsoftware.BeginexaminationsontheOctopus900withoneclickofthemousewithourunique“FollowUp”button

EyeSuite directly interfaces to:

• Octopus900and300• Octopus1-2-3,HFA7xxand7xxi• Octopus101/500/2000/201viaPeritrendsoftware• BothPeritrendandPeridatasoftware

Choose your printoutChoose your favorite printout and graphics representation to match the way you work.

• Freelyconfigurea4-in-1printoutoraseriesreporttheway youwant• ChooseeitherthenewOctopus7-in-1(incolorormonochrome) ortheHFAstyleprintout• Choosefrom3displaymodes:Octopus–Peridata–HFAstyle• Don’twantapapercopy?Savethereportasanimageandview it on your screen

Network and EMR integrationEyeSuite easily integrates into most EMR systems and provides standardized interfaces.

• Unlimitedviewingstationswithfullfunctionalityforonline data analysis• Windows7,WindowsVista,WindowsXPand TerminalServercompatible• SinglePCandServerbasednetworkinstallation

EyeSuite™Octopusstyle

EyeSuite™ HFA style

Page 4: EyeSuite Perimetry Specifications Your reliable partner ... EyeSuite™ HFA style ... or the HFA style printout

9

10

10 22125

5

5 5

8

19

19

18 12

7

7

7

614

18

28

26

+

+

+

5.9

8.1

12.6

21.7

6.5

+

+

5.5

+ +

++

+

+

+

++

++

+

+

+

++

+

+

+

++

++

++

+

+

+ +

++

+

+

++

++

9

5

7

7

10 8

5

5

12

19

18

614

12

18

10

7

2826

19

22

5

102030S

I

N T

2000

0

15

252001 2002 2003 2004 2005

MD Mean defect (OS)

Slope dB yr p2.0 / ( <0.5%)

G 18.12.2003

1/17(+), 0/17(-)

G 29.06.2004

0/16(+), 2/16(-)

G 24.01.2005

1/18(+), 1/18(-)

3 4 5

Intelligent cluster analysisCluster analysis combines high sensitivity with good specificity.

• Testlocationsaregrouped(clustered)alongnervefiberbundles tobetteranalyzechangesincrucialareaslikethenasalstepor themacula• Eliminatestimeconsumingmethodofcountingisolatedpoints• Combinedprobability/deviationgraphhighlightspathologic regions

Polar Graph - combining structure and functionCombining the results of both structure and function is key in obtaining a comprehensive assessmentfor the onset and Progression of Glaucoma. With the Octopus Polar Graph the nerve fiber bundles that are in dan-ger or defective are easily identified.

Trend analysisPerform trend analysis for Octopus Polar Graphs and Cluster Analysis right on your computer screen with specific and comprehensive graphs.

• Multiplespecificoverviewsareavailableattheclickofamouse• Movie-likeanimationtodemonstrateresultstoyourpatient• Cluster-andPointwiseLinearRegressionAnalysis–PLRA

Localdefectsarerepresentedasredlinesandprojectedalongthenervefiberstotheopticdisc.Theprojecteddefectsareverticallymirroredandscaledwithringsfor10,20and30dBdeviation.TheOctopusPolarGraphallowsfordirectcomparisonwithstructuralfindings.

Overview at a glanceVisual Field Analysis starts with getting an over-view.

• OctopusEyeSuiteprovidesacompleteoverviewofall examinationstoshowandanalysechanges• Performsbilateralviewingtogetthecompletepicture• Quicklyselect/deselectexaminationswithasimpleclickofthe mouse

Easy Progression analysisA red icon will display when significant worsening occurs.

• CalculationoftheProgressionrateindBperyearincludingthe probabilitylevelasrecommendedbytheInternationalGlaucoma Societies • Areasfornormalrange(greyband),impairedvision(15dB) andlegalblindness(25dB)provideorientation

Intuitive colour codesSave time by immediately identifying levels of change.A red icon will always display significant wor-sening.

• Aredtrianglethatpointsdownidentifiessignificantworsening• Ayellowdiamondsignalsincreasedfluctuation–asignfor upcomingchanges• A green triangle signals recovery

Discussfindingswithinyourteam.Continuededucationandexchangeofideasaresupportedby Haag-StreitOctopus.

ConnectivityDon’t lose your Data!

Importexistingvisualfieldsfromdifferentperimetersandsoftware.BeginexaminationsontheOctopus900withoneclickofthemousewithourunique“FollowUp”button

EyeSuite directly interfaces to:

• Octopus900and300• Octopus1-2-3,HFA7xxand7xxi• Octopus101/500/2000/201viaPeritrendsoftware• BothPeritrendandPeridatasoftware

Choose your printoutChoose your favorite printout and graphics representation to match the way you work.

• Freelyconfigurea4-in-1printoutoraseriesreporttheway youwant• ChooseeitherthenewOctopus7-in-1(incolorormonochrome) ortheHFAstyleprintout• Choosefrom3displaymodes:Octopus–Peridata–HFAstyle• Don’twantapapercopy?Savethereportasanimageandview it on your screen

Network and EMR integrationEyeSuite easily integrates into most EMR systems and provides standardized interfaces.

• Unlimitedviewingstationswithfullfunctionalityforonline data analysis• Windows7,WindowsVista,WindowsXPand TerminalServercompatible• SinglePCandServerbasednetworkinstallation

EyeSuite™Octopusstyle

EyeSuite™ HFA style

Page 5: EyeSuite Perimetry Specifications Your reliable partner ... EyeSuite™ HFA style ... or the HFA style printout

9

10

10 22125

5

5 5

8

19

19

18 12

7

7

7

614

18

28

26

+

+

+

5.9

8.1

12.6

21.7

6.5

+

+

5.5

+ +

++

+

+

+

++

++

+

+

+

++

+

+

+

++

++

++

+

+

+ +

++

+

+

++

++

9

5

7

7

10 8

5

5

12

19

18

614

12

18

10

7

2826

19

22

5

102030S

I

N T

2000

0

15

252001 2002 2003 2004 2005

MD Mean defect (OS)

Slope dB yr p2.0 / ( <0.5%)

G 18.12.2003

1/17(+), 0/17(-)

G 29.06.2004

0/16(+), 2/16(-)

G 24.01.2005

1/18(+), 1/18(-)

3 4 5

Intelligent cluster analysisCluster analysis combines high sensitivity with good specificity.

• Testlocationsaregrouped(clustered)alongnervefiberbundles tobetteranalyzechangesincrucialareaslikethenasalstepor themacula• Eliminatestimeconsumingmethodofcountingisolatedpoints• Combinedprobability/deviationgraphhighlightspathologic regions

Polar Graph - combining structure and functionCombining the results of both structure and function is key in obtaining a comprehensive assessmentfor the onset and Progression of Glaucoma. With the Octopus Polar Graph the nerve fiber bundles that are in dan-ger or defective are easily identified.

Trend analysisPerform trend analysis for Octopus Polar Graphs and Cluster Analysis right on your computer screen with specific and comprehensive graphs.

• Multiplespecificoverviewsareavailableattheclickofamouse• Movie-likeanimationtodemonstrateresultstoyourpatient• Cluster-andPointwiseLinearRegressionAnalysis–PLRA

Localdefectsarerepresentedasredlinesandprojectedalongthenervefiberstotheopticdisc.Theprojecteddefectsareverticallymirroredandscaledwithringsfor10,20and30dBdeviation.TheOctopusPolarGraphallowsfordirectcomparisonwithstructuralfindings.

Overview at a glanceVisual Field Analysis starts with getting an over-view.

• OctopusEyeSuiteprovidesacompleteoverviewofall examinationstoshowandanalysechanges• Performsbilateralviewingtogetthecompletepicture• Quicklyselect/deselectexaminationswithasimpleclickofthe mouse

Easy Progression analysisA red icon will display when significant worsening occurs.

• CalculationoftheProgressionrateindBperyearincludingthe probabilitylevelasrecommendedbytheInternationalGlaucoma Societies • Areasfornormalrange(greyband),impairedvision(15dB) andlegalblindness(25dB)provideorientation

Intuitive colour codesSave time by immediately identifying levels of change.A red icon will always display significant wor-sening.

• Aredtrianglethatpointsdownidentifiessignificantworsening• Ayellowdiamondsignalsincreasedfluctuation–asignfor upcomingchanges• A green triangle signals recovery

Discussfindingswithinyourteam.Continuededucationandexchangeofideasaresupportedby Haag-StreitOctopus.

ConnectivityDon’t lose your Data!

Importexistingvisualfieldsfromdifferentperimetersandsoftware.BeginexaminationsontheOctopus900withoneclickofthemousewithourunique“FollowUp”button

EyeSuite directly interfaces to:

• Octopus900and300• Octopus1-2-3,HFA7xxand7xxi• Octopus101/500/2000/201viaPeritrendsoftware• BothPeritrendandPeridatasoftware

Choose your printoutChoose your favorite printout and graphics representation to match the way you work.

• Freelyconfigurea4-in-1printoutoraseriesreporttheway youwant• ChooseeitherthenewOctopus7-in-1(incolorormonochrome) ortheHFAstyleprintout• Choosefrom3displaymodes:Octopus–Peridata–HFAstyle• Don’twantapapercopy?Savethereportasanimageandview it on your screen

Network and EMR integrationEyeSuite easily integrates into most EMR systems and provides standardized interfaces.

• Unlimitedviewingstationswithfullfunctionalityforonline data analysis• Windows7,WindowsVista,WindowsXPand TerminalServercompatible• SinglePCandServerbasednetworkinstallation

EyeSuite™Octopusstyle

EyeSuite™ HFA style

Page 6: EyeSuite Perimetry Specifications Your reliable partner ... EyeSuite™ HFA style ... or the HFA style printout

2.0

From the technology leader in perimetry

HAAG-STREIT AGGartenstadtstrasse 103098 Koeniz, SwitzerlandPhone +41 31 978 01 11Fax +41 31 978 02 82 [email protected]

Octopus EyeSuite Perimetry

2

Your reliable partner.

Progression AnalysisStructure Function CorrelationConnectivity

Progression Analysis Structure Function Analysis

EyeSuite® Perimetry Specifications

Basic Functions

Specifications are subject to change without notice

Import of Peritrend and Peridata filesImport of Goldmann GKP filesSingle/Bilateral field display / printoutConfigurable 4-in-1 display / printoutConfigurable series printoutMovie display functionOctopus style display mode ("+" signs)Peridata style display mode (all numbers)HFA style display / single field printoutColor and monochrome printout modesGoldmann Kinetic display / printout

Enhanced FunctionsStatistcial export of static and kinetic perimetry

Cluster and Polar AnalysisPolar GraphCluster AnalysisCluster Trend AnalysisPolar Trend Analysis

Progression RateTrend Analysis on MD, sLV(PSD), DD, LDCalculation of progression rate / significance

ConnectivityOctopus 1-2-3 / HFA 7xx/7xxi serial interfaceOctopus 3xx serial and ethernet interfaceOctopus 101 Peritrend interface for SAPElectronic Medical Record interfaceImport of programs: G, G1, G1X, G2M, M1X, M2, ST, 07, 32, LVC, LVPN1, D1, ET (Mon./Bin.), BG, FG, BT10-2, 24-2, 30-2, 60-4, Nasal step, Sup 36, 64C-40,-76,-80,-Armaly, FF-120, -135, -246, -Arm.Full network supportWindows Terminal Server supportFree viewing stations

PROLITE ADVANCED

Most Advanced Progression Analysis.

Perimeters

HAAG-STREIT USA INC. 3535 Kings Mills Rd Mason, Ohio 45040 Phone +1-513-336-7255 Fax +1-513-336-7260 Toll Free +1-800-787-5426 www.haag-streit-usa.com

HAAG-STREIT UK Ltd Edinburgh Way Harlow Essex CM20 2TT Phone +44-1279 414969 Fax +44-1279 635232 www.haag-streit-uk.com

© H

AAG

-STR

EIT

AG, 3

098

Koen

iz, S

witz

erla

nd

HS-D

oc. n

o. 1

511.

7220

291.

0202

0 – 2

013 –

01