3
Leading theFight Against Fire
Established in 1974, Steel Recon Industries Sdn Bhd (SRI) is proudly a Malaysian company that offers a comprehensive range of firefighting products, equipment and technology solutions through a vast network of distributors worldwide.
Always at the forefront of Malaysian firefighting advances, SRI’s products are certified by international standard boards such as VdS, LPCB, BSI, UL, FM and SAI Global, underlining our commitment to the provision of the most reliable firefighting solutions for local and global needs.
SRI’s products are manufactured in our state-of-the-art facilities which allows us to produce quality products along with the flexibility to cater to specific needs and standards. As we progress into the future, the pioneering spirit that propelled SRI’s success continues to drive us. We will lead the way with technology and cutting-edge research, backed by local expertise and 45 years of experience, to deliver unrivalled protection to your people and property.
4
Malaysia’s First ProprietaryHFC-227ea System
SRI’s SR200 fire suppression system works to extinguish a fire within 10 seconds by depriving the fire of heat and interrupting the chemical reaction that leads to combustion. It is suitable for Class A, B and C fires and provides a highly efficient and reliable solution to protecting high value assets, be it data servers, people or equipment.
The system uses HFC-227ea, a colourless, odourless gas agent that leaves no residue and provides greater protection coverage in a shorter time span
when compared to traditional sprinkler systems. HFC-227ea is stored as a liquified gas, pressured with nitrogen and discharged into the protected area as vapour.
The agent is non-corrosive and does not conduct electricity, ensuring that there is no risk of thermal shock to electronic equipment. Most importantly, the use of SR200 will not deplete oxygen levels to the point where it is unsafe for people who remain in the affected area.
5
SR200
The SR200 system has been widely acknowledged as an equal in its efficiency and reliability to other systems that use HFC-227ea as an extinguishing agent and is actively protecting substations, commercial structures and government offices in major Southeast Asian cities.
In addition to competitive pricing, SRI also strives to provide comprehensive and professional guidance to our clients throughout the buying process – from determining system design, commissioning to after sales service. SRI’s highly trained engineers and technicians are able to provide support to our
clients by assisting them through the testing and commissioning process in order to ensure that the installed system and components are installed and tested in accordance to their operational requirements.
Our team is always on hand to answer any technical questions our customers may have.
The SR200 system is designed, installed and maintained in accordance to NFPA 2001 (Clean Agent fire Extinguishing Systems) and is now UL listed.
Manual Actuator
ElectromagneticActuator
Liquid LevelIndicator
Pilot Hose PneumaticActuator
Valve Assembly
Pressure Gauge
Discharge Hose
Check Valve
SystemSet-up
SR200Cylinders
SR200 Cylinders Specification
7
Note: Option for liquid level indicator on cylinder available.* UL listing available Q2 2019
TPED Welded Cylinders
Part Number
SPS-020-MS-009-EN
SPS-020-MS-016-EN
SPS-020-MS-032A-EN
SPS-020-MS-032B-EN
SPS-020-MS-052-EN
SPS-020-MS-100-EN
SPS-020-MS-120-EN
SPS-020-MS-150-EN
SPS-020-MS-180-EN
SPS-020-MS-200-EN
SPS-021-MS-240-EN *
SPS-031-MS-240-EN *
SPS-021-MS-300-EN *
SPS-022-MS-369-EN *
Cylinder Volume
(L)
9
16
32
52
100
120
150
180
200
240
300
369
Pressure
(Bar)
25
25
25
25
25
25
25
25
25
25
25
25
OD
(mm)
273
273
325
325
406
406
406
462
462
512
508
612
612
Valve Size
1" Thread
1" Thread
1" Thread
1-1/2" Thread
1-1/2" Thread
1-1/2" Thread
1-1/2" and 2" Thread
2" Thread
2" Thread
2" Thread
2" Thread
3" Flange
3" Flange
3" Flange
Total Height,
C (mm)
270
342
480
740
907
1070
1316
1223
1353
1348
1195
1440
Overall Height with Valve
D (mm)
440
512
667
925
1094
1257
1528
1430
1560
1614
1454
1699
TPED Seamless Cylinders
Part Number
SPS200-MS-010-EN
SPS200-MS-020-EN
SPS200-MS-030-EN
SPS200-MS-050-EN
SPS200-MS-080-EN
SPS200-MS-100-EN
SPS200-MS-140-EN
Cylinder Volume
(L)
10
20
30
50
80
100
140
Pressure
(Bar)
42/50
42/50
42/50
42/50
42/50
42/50
42/50
OD
(mm)
140
204
204
229
360
360
360
Valve Size
1" Thread
1" Thread
1" Thread
1-1/2" Thread
1-1/2" Thread
1-1/2" Thread
2" Thread
Total Height,
C (mm)
805
780
1115
1440
1025
1240
1690
Overall Height with Valve
D (mm)
919
894
1229
1577
1162
1377
1852
DOT Welded Cylinders
Part Number
SPS061-MS-275-DT *
SPS062-MS-369-DT *
Cylinder Volume
(L)
275
369
Pressure
(Bar)
25
25
OD
(mm)
508
610
Valve Size
3" Thread
3" Thread
Total Height,
C (mm)
1539
1454
Overall Height with Valve
D (mm)
1806
1712
8
SR200 Components
Part Number
Valve Size
Valve Body Material
Temperature Range
Actuator Connection
Pilot Hose Connection
Pressure Gauge Connection
Valve Outlet Connection
SPS100-GM-025-UL
1”
Brass
−10 °C to 60 °C
1-1/4” X 18UNEF
1/8” NPT
1/8” NPT
1-7/16” - 12 UN
SPS100-GM-038-UL
1-1/2”
Brass
−10 °C to 60 °C
1-1/4” X 18UNEF
1/8” NPT
1/8” NPT
1-7/8” X 12 UN
SPS100-GM-050-UL
2”
Brass
−10 °C to 60 °C
1-1/4” X 18UNEF
1/8” NPT
1/8” NPT
2-1/2” X 12 UN
SPS100-GM-080-UL
3”
Brass
−10 °C to 60 °C
1-1/4” X 18UNEF
1/8” NPT
1/8” NPT
3” Grooved Connection
Discharge Valve
Part Number
Material
Max. Working Pressure
Temperature Range
Length from Elbow Inlet
Elbow Inlet
Outlet
SPS-SR-010-38MM
50 bar
−10 °C to 60 oC
465 mm
1-7/8” – 12 UNJ
2” BSP
SPS-SR-010-38M
90 bar
−10 °C to 60 °C
465 mm
1-7/8” – 12 UNJ
2” BSP
SPS-SR-010-50MM
40 bar
−10 °C to 60 °C
520 mm
2-1/2” – 12 UNJ
2-1/2” BSP
SPS-SR-012-50MM
80 bar
−10 °C to 60 °C
520 mm
2-1/2” – 12 UNJ
2-1/2” BSP
SPS-SR-012-80MMFITP90-GRV080-OR
Stainless Steel 304 hose double wire
braids reinforcement
28 bar
−10 °C to 60 °C
480 mm
3” Grooved Connection
3” Grooved Connection
Synthetic Rubber Hose with high tensile steel wiresingle braid reinforcement
Discharge Hose
Part Number
Material
Max. Working Pressure
Temperature Range
Length from Elbow Inlet
Elbow Inlet
Outlet
SPS-SR-011-50MM
Synthetic Rubber Hose with high tensile steel wire single braids reinforcement
40 bar
−10 °C to 60 °C
520 mm
2-1/2” – 12 UNJ
2-1/2” BSP
Extended Elbow Discharge Hose
9
SR200 ComponentsCheck ValvePart Number
Material
Seat
Washer
Nut
Spline
Temperature Range
Inlet and Outlet Connections
SPS101-GM-050-UL
Gun Metal
Nylon
Zinc Plated Mild Steel
Stainless Steel
Stainless Steel
−10 °C to 60 °C
2” BSP
SPS101-GM-065-UL
Gun Metal
Nylon
Zinc Plated Mild Steel
Stainless Steel
Stainless Steel
−10 °C to 60 °C
2-1/2” BSP
SPS101-GM-080-UL
Zinc Plated Mild Steel
Gun Metal
N/A
N/A
N/A
−10 °C to 60 °C
6” x 3” Grooved Connection
Pilot Line HosePart Number
Overall Length (mm)
Material
Temperature Range
Hose Connections
SPS-SR-008-560MM
560
Synthetic Rubber Hose with 2 high tensile steel wire braids
reinforcement
−10 °C to 60 °C
1/8” BSP
SPS-SR-008-760MM
760
Synthetic Rubber Hose with 2 high tensile steel wire braids
reinforcement
−10 °C to 60 °C
1/8” BSP
Part Number
Type
Temperature Range
Connection to Valve
SPC170-PG-25B-HFC
Spring Tube Manometer
−10 °C to 60 °C
1/8 NPT
SPC170-PG-42B-HFC
Spring Tube Manometer
−10 °C to 60 °C
1/8 NPT
SPC170-PG-50B-HFC
Spring Tube Manometer
−10 °C to 60 °C
1/8 NPT
Pressure Gauge 25 Bar / 42 Bar / 50 Bar
Part Number
Wire
Temperature Range
Connection to Valve
SPC172-PS-25B-HFC
18 Gage SXL, 36” Length
−10 °C to 60 °C
1/8 NPT
SPC172-PS-42B-HFC
18 Gage SXL, 36” Length
−10 °C to 60 °C
1/8 NPT
SPC172-PS-50B-HFC
18 Gage SXL, 36” Length
−10 °C to 60 °C
1/8 NPT
Pressure Gauge 25 / 42 Bar / 50 Barwith Low Pressure Switch
10
Liquid Level Indicator
Valve Outlet Adaptor
Part Number
Material
Actuating Force
Connection
SPS110-XX-MNL-UL
Brass & Stainless Steel
12 – 40 lbs
1-1/8 x 18 UNEF
Manual Actuator
Part Number
Material
Actuating Force
Connection
Supply Voltage
Firing Current
Temperature Range
Actuating Force
Connection
SPS110-XX-LAT-UL
Brass & Stainless Steel
12 – 40 lbs
1-1/4 x 18 UNEF
24V DC
0.5 Amp Maximum
−10 °C to 60 °C
12 – 40 lbs
1-1/8 x 18 UNEF
Electrical Actuator
Part Number
Material
Connection
Pilot Hose Connection
SPS111-XX-PNE-UL
Brass
1-1/4” x 18 UNEF
1/8” NPT
Pneumatic Actuator
Part Number
Valve Size
Valve Body Material
Valve Outlet Connection
SPC227-CS-DN25 ADAPTOR
1 ”
Brass
1-7/16” - 12 UN
SPC227-CS-DN33 ADAPTOR
1-1/2 ”
Brass
1-7/8” X 12 UN
SPC227-CS-DN49 ADAPTOR
2 ”
Brass
2-1/2” X 12 UN
Part Number
Cylinder Size
Neck Ring Inlet Size
SPS040-CU-001-UL
150L and 200 L
2”-11.5 NPSC
11
Gas Extinguishing Panel
Type 1 Type 2 Type 3
Part Number
Normal Voltage
Dimension (mm)
Weight
Approval
FAS-198-12V-7AH
12V
15mm (L) x 60mm (W) x 90mm (H)
Max. 2.4 kg
UL Approved
Battery - Sealed Lead Acid
Detection Components
Part Number
Main Supply Voltage
Internal Power Supply
Output Current
Battery Requirement
Battery Charge Current
Sounder Output Rating
No. of Auxiliary Outputs
Relay Contract Rating
Maximum Detectors Per Zone
Extinguishant Release Output
No. of Monitored Inputs and Type
Dimensions
Standard
Approval
FAS-EP203
230V AC, 50/60Hz
24V DC NOMINAL
3A @230VAC (MAX)
2x12V DC 7AH
0.7A
21-28V DC, fused@200mA per circuit
6 (Fire, Local Fire, Fan, 1st Stage, 2nd Stage, Fault)
300V DC.1A MAX
20 NOS.
21-28V DC, rated at 1Amp for 5mins
6 (Manual Release, Flow Switch Low Pressure, Mode, Hold, Abort
439mm x 276mm x 70mm
EN 12094-1:2003EN 54-2:1997 + A1:2006 + A2:2007EN 54-4:1997 + A1:2002 + A2:2006
LPCB and Bomba
FAS-PFC-4410-RC-UL
120V AC / 220 V AC
24V DC NOMINAL
200mA (MAX)
2x12V DC 7AH
0.7A
24V DC RATED 1 AMP
1 NO.
3 AMP, 30V DC
20 NOS.
24V DC, rated at 1Amp
-
457mm x 369mm x 21mm
NFPA
UL and FM
FAS-HOCHIKI-HCVR3-UL
115 or 230V AC 50 / 60Hz
3 Amps total including battery charge 28V +/- 2V
Auxiliary 24V DC output: 18 – 28 V DC special application output,
500mA maximum
2x12V DC 7AH
0.7A
18 to 28V DC @ 50 mA continuous
1st stage relay, 2nd stage relay, extract relay, trouble relay, local fire,
fire relay
30V DC @ 1A Maximum
20 NOS.
18 to 18V DC, 1Amp for 5 mins
5 (Mode Select, Manual Release, Abort, Release Pressure Switch, Low
Pressure Switch)
368mm x 310mm x 90mm
NFPA
UL and FM
12
Part Number
Operating Voltage
Dimension
FAS-251
24V DC/75mA pe light on
190mm x 90mm x 110mm
Discharge IndicatorPart Number
Operating Voltage
Alarm Current
Decibel 10ft
FAS-194 / FAS194-LA-150-UL
24V DC
0.02A
95dB
6" Alarm Bell
Part Number
Operating Voltage
Sounder Output
Min currentconsumption
FAS-4A-CS100FAS-4A-Y04-24VDC
FAS-4A-GSTM9414R-UL
24V DC
106dB(A) AT 1MTR
20mA
Sounder
Part Number
Operating Voltage
FAS-258FAS-258-SIGMAK1823-10-
UL
20mA
Abort Switch
Part Number
Currenting Rating
Dimension (mm)
Indication
Enclosure
FASKKSB-15
220mA
260mm (W) x 105mm (H) x 60mm (D)
Red
Mild steel with wrinkle back
Evacuate SignPart Number
Dimension (mm)
FAS260-LA-28v-RD FAS260-PS-28V-RD
100mm (W) x 100mm (H) x 90mm (D)
Gas Release Key-Switch
Part Number
Contact Rating
FAS072-HOCHIKI-UL FAS072-ANSUL-UL
10A @ 12V AC
Manual Pull StationPart Number
Maximum Voltage
Current Rating
FAS221-KAC-VDS
24V DC
2 Amps
Manual Call Point
Part Number
Voltage DC
Standby Current (max)
Alarm Current (max)
Surge Current
Start Up Time (max)
Permissable Current (max)
Emitting Duty
Temperature Range
Humidity
Material of Body
Colour of Body
Approval
FAS-HCK-SOC-24VN
24V DC
59µA
150mA
160µA
Instant
NA
Photoelectric infrared LED
(0 °C to 49 °C)
Max 95% RH Non-Condensing
ABS Blend
Bone PC
UL/FM
Optical Smoke DetectorPart Number
Voltage DC
Rate of Rise
Temperature Range
Materials of Body
Colour of Body
Approval
FAS-HCK-DSC-EA
24V DC
15°F/mins
-10 °C - +50 °C
ABS Blend
Bone
UL
Heat Detector
Disclaimer
Steel Recon Industries Sdn Bhd (‘SRI’) makes every effort to maintain the accuracy and quality of the information provided on this Catalogue. However, SRI cannot guarantee and assumes no legal liability or responsibility for the accuracy or completeness of the information provided. The information contained on this catalogue is for general guidance only. Although measures are taken to ensure the information in our catalogues is as timely and accurate as possible, SRI assumes no responsibility for the accuracy of such information or its relevance to a specific use or application. Our products are subject to continuous technical progress and constant development. We therefore reserve the right, at any time, to change performance characteristics or specifications without prior notice. Actual performance of products may vary based upon many factors and may be less than stated. Differences in environmental factors, installation methods and maintenance intervals may affect product performance. Actual products may differ slightly in appearance to images shown. You should take appropriate professional advice on your particular circumstances because the application of our equipment may vary depending on particular circumstances. The copyright of all content on this catalogue is owned by SRI and/or the various manufacturers of our equipment. No part of the SRI catalogue may be changed, reproduced, stored in or transmitted on any website or medium without the prior written permission of SRI. Requests to republish any material must be sent to [email protected].
+(60)3-8023 2323 [email protected]
No. 8, Persiaran Subang (Jalan Subang 7), Taman Perindustrian Subang,47610 Subang Jaya, Selangor Darul Ehsan, Malaysia.
Steel Recon Industries Sdn. Bhd.