42
Leading fullservice provider of metal fabrics for architectural solu7ons The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

Facades: Chi 2013 - Tom Bialk

Embed Size (px)

DESCRIPTION

Facades+: Chicago 2013 Tom Bialk Powerpoint Presentation

Citation preview

Page 1: Facades: Chi 2013 - Tom Bialk

Leading  full-­‐service  provider  of  metal  fabrics  for  architectural  solu7ons  

The image cannot be displayed. Your computer may not have enough memory to open the image, or the image may have been corrupted. Restart your computer, and then open the file again. If the red x still appears, you may have to delete the image and then insert it again.

Page 2: Facades: Chi 2013 - Tom Bialk

Who is GKD Metal Fabrics?

Page 3: Facades: Chi 2013 - Tom Bialk

What Do We Weave?

Page 4: Facades: Chi 2013 - Tom Bialk
Page 5: Facades: Chi 2013 - Tom Bialk

Projects  

Page 6: Facades: Chi 2013 - Tom Bialk

UCSF

SUNSHADING

San  Francisco,  CA  

 

Page 7: Facades: Chi 2013 - Tom Bialk

Education City

Doha,  Qatar  

 

SUNSHADING

Page 8: Facades: Chi 2013 - Tom Bialk

European Court of Justice

Luxemburg  City,  Luxemburg  

 

SUNSHADING

Page 9: Facades: Chi 2013 - Tom Bialk

Okatech – Public Library

Des  Moines,  IA  

 

SUNSHADING

Page 10: Facades: Chi 2013 - Tom Bialk

Benefits  

Page 11: Facades: Chi 2013 - Tom Bialk

Benefits – Stainless Steel

Page 12: Facades: Chi 2013 - Tom Bialk

Benefits - Flexible

Page 13: Facades: Chi 2013 - Tom Bialk

Benefits – Minimized Sub-Structure

Page 14: Facades: Chi 2013 - Tom Bialk

Benefits – Attachments

Page 15: Facades: Chi 2013 - Tom Bialk

Benefits – Solar Management

Lake  Nona,  FL  

 

Page 16: Facades: Chi 2013 - Tom Bialk

Sunshading Benefits – Reduced Cooling Loads

Page 17: Facades: Chi 2013 - Tom Bialk

Benefits - Daylighting

UF  Research  Center-­‐  Lake  Nona,  FL  

 

Page 18: Facades: Chi 2013 - Tom Bialk

Focus:  Sun  Shading  How  does  it  work?  

Page 19: Facades: Chi 2013 - Tom Bialk

How does it work?

Incidence  Angle  =  20  Degrees  

 Incidence  Angle  =  51  Degrees  

 

Page 20: Facades: Chi 2013 - Tom Bialk

How does it work?

Page 21: Facades: Chi 2013 - Tom Bialk

Solar Properties 0-30 DEGREES = 8% IMPROVEMENT

30-60 DEGREES = 40% IMPROVEMENT

Page 22: Facades: Chi 2013 - Tom Bialk

Solar  Proper7es  

Page 23: Facades: Chi 2013 - Tom Bialk

Solar Properties

-Transmittance -Reflectance

-Visible Light -Solar Energy

-SHGC -Incidence Angle

-0 degrees -30 degrees -60 degrees

Page 24: Facades: Chi 2013 - Tom Bialk

Defining Design Requirements

We  work  with  the  architect  to  meet  or  exceed  the  minimum  requirements  to  achieve  the  desired  solar  heat  gain  coefficient.  

Courtesy  of  ASHRAE  

 

Page 25: Facades: Chi 2013 - Tom Bialk

Sunshading  Meshes  

Page 26: Facades: Chi 2013 - Tom Bialk

Solar Metal Fabrics – Omega 1510

Page 27: Facades: Chi 2013 - Tom Bialk

Solar Metal Fabrics – Lago

Page 28: Facades: Chi 2013 - Tom Bialk

Solar Metal Fabrics – Escale 5x1

Page 29: Facades: Chi 2013 - Tom Bialk

Solar Metal Fabrics – Helix 24

Page 30: Facades: Chi 2013 - Tom Bialk

Case  Studies  

Page 31: Facades: Chi 2013 - Tom Bialk

EMU- Ypsilanti, MI - Case Study

YpsilanA,  MI  

 

Page 32: Facades: Chi 2013 - Tom Bialk

EMU- Ypsilanti, MI - Case Study

   UN-­‐SHADED  CURTAIN  WALL  94  DEGREES  

   SHADED  CURTAIN  WALL  82  DEGREES  

EXTERIOR  AIR  TEMP  75  DEGREES  

Page 33: Facades: Chi 2013 - Tom Bialk

GKD-USA Project - Cambridge, MD- Case Study

Page 34: Facades: Chi 2013 - Tom Bialk

   UN-­‐SHADED  WALL  109  DEGREES  

   SHADED  CURTAIN  WALL  98  DEGREES  

EXTERIOR  AIR  TEMP  87  DEGREES  

GKD-USA Project - Cambridge, MD- Case Study

Page 35: Facades: Chi 2013 - Tom Bialk

   SHADED  CURTAIN  WALL  MULLION  89  DEGREES  

   UN-­‐SHADED  CURTAIN  WALL  MULLION  98  DEGREES  

INTERIOR  AIR  TEMP  81  DEGREES  

GKD-USA Project - Cambridge, MD- Case Study

Page 36: Facades: Chi 2013 - Tom Bialk

Cal Iso Project - Folsom, CA - Case Study

Page 37: Facades: Chi 2013 - Tom Bialk

   UN-­‐SHADED  CURTAIN  WALL  121  DEGREES  

   SHADED  CURTAIN  WALL  100  DEGREES  

EXTERIOR  AIR  TEMP  90  DEGREES  

Cal Iso Project - Folsom, CA - Case Study

Page 38: Facades: Chi 2013 - Tom Bialk

   UN-­‐SHADED  CURTAIN  WALL    

MULLION  97  DEGREES  

   SHADED  CURTAIN  WALL  

MULLION  82  DEGREES  

Cal Iso Project - Folsom, CA - Case Study

Page 39: Facades: Chi 2013 - Tom Bialk

   SHADED  FLOOR  

77  DEGREES  

   UN-­‐SHADED  FLOOR  

86  DEGREES  

INTERIOR  AIR  TEMP  71  DEGREES  

Cal Iso Project - Folsom, CA - Case Study

Page 40: Facades: Chi 2013 - Tom Bialk

Benefits -Stainless Steel -Flexible -Minimized Sub-Structure -Unlimited Attachments -Solar Management -LEED

Page 41: Facades: Chi 2013 - Tom Bialk

Stop  by  the  GKD  Exhibit  to  learn  more  

Page 42: Facades: Chi 2013 - Tom Bialk

www.GKDmetalfabrics.com