4
Solus E. coli O157 ELISA Assay and Automated Workflow Package FAST EFFICIENT E. COLI TESTING

FAST - PerkinElmer · 2020. 7. 3. · 2 EFFICIENT TESTING: 18 HOURS TO RESULTS E. coli testing the simple, efficient, cost-effective way TEST MULTIPLE MATRICES WITH A SINGLE ASSAY

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FAST - PerkinElmer · 2020. 7. 3. · 2 EFFICIENT TESTING: 18 HOURS TO RESULTS E. coli testing the simple, efficient, cost-effective way TEST MULTIPLE MATRICES WITH A SINGLE ASSAY

Solus E. coli O157 ELISAAssay and Automated Workflow Package

FAST EFFICIENTE. COLI TESTING

Page 2: FAST - PerkinElmer · 2020. 7. 3. · 2 EFFICIENT TESTING: 18 HOURS TO RESULTS E. coli testing the simple, efficient, cost-effective way TEST MULTIPLE MATRICES WITH A SINGLE ASSAY

2

EFFICIENT TESTING: 18 HOURS TO RESULTS

E. coli testing the simple, efficient, cost-effective way

TEST MULTIPLE MATRICES WITH A SINGLE ASSAY

Efficiency Made Simple

For food testing laboratories everywhere, our Solus E. coli O157 ELISA pathogen test kit is an easy-to-use, cost-effective, and efficient method for the detection of E. coli O157 in food and environmental samples.

Presented in an immunoassay format, the Solus E. coli O157 ELISA kit is versatile and can be used manually or in conjunction with automation. Laboratories with higher sample throughput can use the Dynex DS2 automated solution to improve laboratory workflow, significantly reducing technician time and increasing the capacity for testing.

The smart way to test for E. coli

With our Solus E. coli O157 ELISA kit, you have a fast, sensitive immunoassay that delivers results in about 18 hours – with 2 hours to presumptive negative/positive results after selection enrichment. In addition, our Solus solutions can make your lab more efficient and cost effective – and your results more reliable than ever before.

Cost effective

• Increased laboratory efficiency

• Reduced demand on resources

• Reduced waste

Efficient

• High efficiency when automated

• Significantly reduced technician time

Reliable

• Independent validation demonstrates high levels of sensitivity and specificity

Solus E. coli O157 ELISA Benefits

Solus E. coli O157 ELISA Kit

Page 3: FAST - PerkinElmer · 2020. 7. 3. · 2 EFFICIENT TESTING: 18 HOURS TO RESULTS E. coli testing the simple, efficient, cost-effective way TEST MULTIPLE MATRICES WITH A SINGLE ASSAY

3

HIGH THROUGHPUT FOR BETTER EFFICIENCY

EASY TO IMPLEMENT, EASY TO USE

Solus E. coli O157 ELISA Workflow

Solus E. coli O157 ELISA automated process is carried out on a Dynex DS2 instrument. A single DS2 processes two 96-well plates simultaneously, generating results for up to 558 samples in an 8-hour shift.

Once the instrument is loaded, the technician can walk away for up to 2 hours during each run, providing time to carry out other essential laboratory tasks. Dynex DS2

Ordering information

Product Code Product Description Pack Size

EC-048S Solus E. coli O157 ELISA 96 wells

MED 026-0.50 kg mTSB 500 g

DS2000 DS2 Automation 1

Test Methodology

STEP 1Add sample to mTSB +

novobiocin, mix, and incubate

Incubation: 41.5 °C, 16-20 hrs.

STEP 2Transfer 1 ml culture

to boiling tube

Boil: 85-100 °C, 15-20 min.

STEP 3Pipette 100 µl sample

into wells (plus controls)

Incubation:37 °C, 30 min. periods

STEP 4Wash plate and add 100 µl of conjugate

Incubation:37 °C, 30 min. periods

STEP 5Wash plate and add 100 µl of substrate

Incubation: ambient room temp.,10 min.

STEP 6Add 100 µl of stop solution

Read Plate: 450 nm

Validated to ISO 16140 and approved for use by AFNOR. Certificate number SOL 37/03-10/15.

Solus Automated Process

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

Negative Control Blank Well Positive (After Substrate Addition)Positive Control Sample wells Positive (After Stop Solution Addition)

Sample

Page 4: FAST - PerkinElmer · 2020. 7. 3. · 2 EFFICIENT TESTING: 18 HOURS TO RESULTS E. coli testing the simple, efficient, cost-effective way TEST MULTIPLE MATRICES WITH A SINGLE ASSAY

For a complete listing of our global offices, visit www.perkinelmer.com/ContactUs

Copyright ©2020, PerkinElmer, Inc. All rights reserved. PerkinElmer® is a registered trademark of PerkinElmer, Inc. All other trademarks are the property of their respective owners. 76773 PKI

PerkinElmer, Inc. 940 Winter Street Waltham, MA 02451 USA P: (800) 762-4000 or (+1) 203-925-4602www.perkinelmer.com

Workflow Comparison: Solus E. coli O157 ELISA vs ISO 16654

Timescale Day 0 Day 1

ISO 16654

Solus E. coli O157 ELISA

Take 1-2 ml heat kill, and test

Report -ve

+ve result confirm

immuno- magnetic capture

& wash

25 g food in 225 ml mTSB+n

immuno- magnetic capture

& wash

Incubate 41.5 °C 18-24 hrs.then take sample

Plate 50 ul on to CT-SMAC

medium

Incubate@ recommended temp and time

+ve or -ve result confirm

Plate 50 ul on to CT-SMAC

medium

25 g food in 225 ml mTSB+n

Incubate 41.5 °C 16-20 hrs.

Incubate 41.5 °C 6hrs.

then take sample

Incubate 37 °C 18-24 hrs.

+ve or -ve result confirm

Incubate 37 °C 18-24 hrs.

For sales and support contacts, please visit www.solusscientific.com

Solus Automated Process

1 2 3 4 5 6 7 8 9 10 11 12

100 ml

Solus Auto

mated Proce

ss

1 2

3

4

5 6

7

8

9 10 1

1 12

100 ml

Solus Automated Process

1 2 3 4 5 6 7 8 9 10 11 12

100 ml

Solus Automated Process

1 2 3 4 5 6 7 8 9 10 11 12

100 ml

Solus Automated Process

1 2 3 4 5 6 7 8 9 10 11 12

100 mlSolus Automated Process

1 2 3 4 5 6 7 8 9 10 11 12

100 ml

Solus Auto

mated Proce

ss

1 2

3

4

5 6

7

8

9 10 1

1 12

100 ml

Solus Automated Process

1 2 3 4 5 6 7 8 9 10 11 12

100 ml

Solu

s Au

tom

ated Pro

cess

1 2 3 4 5 6 7 8 9 10 11 12

100 ml

Solus Automated Process

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

Solu

s Au

tom

ated Pro

cess

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

Solu

s Au

tom

ated Pro

cess

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

1 2 3 4 5 6 7 8 9 10 11 12

Plate 50 ul on to second

medium

Incubate@ recommended temp and time

Plate 50 ul on to second

medium

+ve or -ve result confirm

+ve or -ve result confirm

Solus Automated Process

1 2 3 4 5 6 7 8 9 10 11 12

100 mlSolus Automated Process

1 2 3 4 5 6 7 8 9 10 11 12

100 ml