5
Next Generation FDU Front Desk Unit 7 8 9 4 5 6 1 2 3 0 Generation E-760 Series Solitaire 710-II/710 Series Remote Access Controller (RAC) Exit Device Operator Model 720-II Exit Device Operator Model 730 System Overview 17 Kaba Lodging Systems Product Catalog - M303_007-008 FDU

FDU Catalog

Embed Size (px)

DESCRIPTION

FDU 4 Catalog in english

Citation preview

Page 1: FDU Catalog

Next Generation FDU Front Desk Unit

7 8 94 5 61 2 30

Generation E-760 Series

Solitaire 710-II/710 Series

Remote Access Controller(RAC)

Exit DeviceOperatorModel 720-II

Exit DeviceOperatorModel 730

System Overview

17Kaba Lodging Systems Product Catalog - M303�_�007-�008

FDU

Page 2: FDU Catalog

Next Generation FDU Front Desk Unit

The FDU does not require a separate computer or database. Hotel management can control any aspect of the system and view, print or save a lock or FDU audit directly from the FDU. The FDU communicates with the user through text messages on a backlit LCD screen, and all functions are conveniently menu-driven. Its simple menus, available in a choice of languages, are easy to follow. The major functions of the FDU can be learned in minutes.

The FDU encodes keycards and programs and audits locks. With a minimum eight-hour battery backup, the FDU can continue to manage the system even during a power failure. It can be used to program locks or register guests away from the front desk, without needing to plug into a power outlet or a computer terminal.

Full audit tracking capability is built into the FDU, which records the details of the last 4,000 transactions, including the operator ID of the employee operating the unit. Together with the lock audit trail, this information can determine not only which keycard was used to open a door, but also who issued that keycard.

Guest Service Attendants at the front desk use the FDU primarily to encode Guest keycards, while management can use the FDU to make the keycards required by staff and to set the system parameters, time zones, hotel public area usage, system language and keycard expires.

The FDU has a serial port for communication with a Property Management System (PMS) and for printing audits or a record of staff keycard encoding and USB ports for transferring data to a PC.

FDU Access Control Solutions

� 1/�”(�� cm)

7 1/�”(18 cm)

Front view

� 1/�”(�7 mm)

Side view

18 Kaba Lodging Systems Product Catalog - M303�_�007-�008

FDU

Page 3: FDU Catalog

Next Generation FDU Front Desk Unit

System Benefits • Increase security immediately and economically • Reduce re-keying costs • No lock wiring required • Stand alone operation - no computer required • No networking is required if the hotel chooses to have multiple FDUs for convenience of operation • No computer knowledge is required to operate the FDU • Staff find the system easy to use • Easy-to-follow prompts guide the user through the FDU functions • Multi-track encoding & reading • Encode information on track 2 for POS use • Lost or stolen keycards pose no threat

Security Features • Time-based access control system with user selectable keycard expiry • Keycard encryption: Proprietary and unique to each installation • Security: Authorization keycard or PIN required for any FDU operation • Different levels of authorization: keycards available, ranging from front desk staff to upper management users • Authorization levels: 5 • Audit trail: Last 4,000 keycard-making transactions, sorted by room, authorization, or key type • Setup and audit memory: Internal real time clock with non-volatile memory • Lock Access levels: 15 levels

System Features

Property size: 16 000 rooms and 1,000 common door suites (maximum of 8 inner doors per suite)Common areas: 8 guest and 16 staff areasRestricted areas: 200Staff access levels: 3 Master levels and 5 Sub-Master levels per lock: 255 sections, floors, areas, groups, zonesRoom Number Format: 5 digits numericKeycards validity selectable: From one hour to 7 yearsPre-registered guest: Keycards can be made up to 10 days in advanceTime zone: Predefined Time Zones available for staff keycards in locks 8 customer defined Time Zones available for Guest, Staff & passage option in RAC Card ReadersKeycards read and encoded: Low or High coercivity Track 1, 2 or 3 magnetic stripe cardsKeycard handling: Manual swipe with wide acceptable speed range for magnetic stripe keycardCommunication ports: Serial and USB, for external PC, printer and SMART encoderCommunication with locks: Programming moduleCommunication Serial Cable with other FDUs:

Compatible with Generation E-760 Series, Solitaire 710-II/710, SolitaireSMART and System 700 locks

System Specifications

1�Kaba Lodging Systems Product Catalog - M303�_�007-�008

FDU

Page 4: FDU Catalog

Next Generation FDU Front Desk Unit

System Features Con’t

Firmware: Upgradeable, via USBCompatibility: POS and PMS

FDU Characteristics:

Mode of Operation: Front Desk (optionally interfaced to PMS), portable Lock Maintenance Unit, Point-Of-Sale verifierMaintenance: It has no moving parts so it will require very little service other than occasional cleaningPower Supply: 9V plug-in power supply available for North America, European, U .K . and AustraliaBattery Backup: Internal, minimum 8-hour duration (unit fully operable) with low battery alarmLanguages: English, French, SpanishAudits: Last 4000 keycard-making transactions, sorted by room, authorization, or key type

The FDU can store up to 10 lock audits in memory Either type of audit-lock and FDU log - can be reviewed on screen, shared on a PC or printed for record keeping on any standard printer

Physical Characteristics:

Keypad: 14 keys (fully tactile) plus four cursor keysDisplay: Adjustable display contrast with backlit LCD, 4 lines of 20 charactersWeight: 2 Lbs (0 .9Kg)Dimensions: 7 .2 (W) X 9 .5 (L) X 2 .2 (H) inches (180 X 240 X 57 mm)Housing Construction: Impact resistant plastic (black), with rubber feet and carrying handles

Environmental Operating Conditions

Temperature: 0°C to 40°C (32°F to 104°F)Humidity: 0% to 85% (non-condensing)Housing: Fire retardant plastic housing Splash resistantCertifications, 1,000,000 swipe life expectancy Approvals and Testing: Complies with FCC part 15 class A Complies with the EMC directives 89/336/EEC, CE certified

Warranty

Warranty: 2 years

�0 Kaba Lodging Systems Product Catalog - M303�_�007-�008

FDU

Page 5: FDU Catalog

Power SupplyModel

F D U L 14 -Coercivity

LEncoding Tracks

1Version

- EDocumentation Cables

2

Next Generation FDU Front Desk Unit

FDU for SMART Encoder Part Number

Lock Type

780-A Encodes magnetic tracks 1, 2 and 3 for Solitaire 710, 710-II, Solitaire SMART or E-760 locks .

780-B Encodes magnetic tracks 1 and 3 for Solitaire 710, 710-II or E-760 locks and track 2 for Point-Of-Sale use .

780-H Hi-C encoding on Track 3

Cables External Encoder1st language

E English

S Spanish F French G German I Italian

2nd language

E English

S Spanish F French G German I Italian

5 FDU to FDU and FDU to Solitaire SMART Lock

6 FDU to FDU, FDU to SolitaireSMART Lock and FDU to Exit Device 730 -2

Kaba SMARTKeycard Encoder

Z Refurbished (if available)

1 US, Canada & Japan 120V 60Hz

2 Australia 240V 50Hz

3 Europe 240V 50Hz

4 United Kingdom 220V 50Hz

Power Supply

Build the model number with the desired options

-

Standard Model

-

Power Supply 1st Language 2nd LanguageModel

Model 2nd Language1st LanguagePower Supply

7

Cables

Cables

7 8 0

8 0 A 1 E S 5

External Encoder

Next Generation FDU Product Number

Build the model number with the desired options

Standard Model

Power SupplyModel

F D U L 14 -Coercivity

LEncoding Tracks

1Version

- EDocumentation Cables

2

External Encoder

Model Cables

0 - None2 - FDU to FDU and FDU to Solitaire 710, 710-II Lock

3 - FDU to FDU, FDU to Solitaire 710, 710-II Lock and FDU to Exit Device 720

4 FDU to FDU, FDU to System 700 II Lock

7 FDU to FDU, FDU to System 700 II Lock, FDU to Exit Device

8 FDU to FDU and FDU to 760, 770 locks or Exit Devices

L LoCH HiC

A - Triplewide Encodes across tracks 1, 2 and 3B - Triple trackEncodes on 3 distinct tracks (1, 2 and 3) and can use track 2 for POS .

FDU4 1 US, Canada & Japan 120V 60Hz

2 Australia 240V 50Hz

3 Europe 240V 50Hz

4 United Kingdom 220V 50Hz

Power SupplyCoercivity Encoding Tracks Version Documentation

1 E EnglishS SpanishF Francais

�1Kaba Lodging Systems Product Catalog - M303�_�007-�008

FDU