FEA Analysis for Hull MEG Storage Tank T-5601AB_Rev 01

Embed Size (px)

DESCRIPTION

AWEQWE asdqAWE QWD ASDASDA WEQ SDASDASDAWEQW RRQWER

Citation preview

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    1 OF 51

    DATE REV. PREPARED BY CHECKED BY APPROVED BY 09-04-2014 01 FZL YLZ MHL

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    2 OF 51

    TABLE OF CONTENT 1.0 GENERAL ............................................................................................................................ 3 1.1 Scope ................................................................................................................................... 3 1.2 Code, Standards and References......................................................................................... 3 1.3 Modelling Of Structures ........................................................................................................ 3 1.3 Strength of Materials ............................................................................................................ 4 2.0 FEA ANALYSIS ................................................................................................................... 6 2.1 Introduction .......................................................................................................................... 6 2.2 Design Data ......................................................................................................................... 6 2.2.1 Operating Condition .................................................................................................................... 7 2.2.2 Survival Condition ..................................................................................................................... 18 2.2.3 Extreme Condition .................................................................................................................... 29 3.0 FEA RESULTS .................................................................................................................. 40 3.1 Plate Centre Stresses Summary .................................................................................................. 40 3.2 Deflection Plot ............................................................................................................................... 43

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    3 OF 51

    1.0 GENERAL 1.1 SCOPE

    This document represents the FEA Analysis for Hull MEG Storage Tank of Malikai EPC TLP Project.

    1.2 CODE, STANDARDS AND REFERENCES

    1 Roarks Formula of Stresses and Strain, 8th Edition 2011. 2 AISC-ASD 9th Edition 1989, Manual of Steel Construction Allowable Stress Design. 3 API RP 2A, Recommended Practice for Planning, Designing and Construction Fixed Offshore Platform - WSD 4 DEP 37.81.10.31-Gen, Structural Steel Design of Small Deepwater Offshore Skids, Facility Packages, and Subsea Sleds Manifolds. 5 Topsides General Design Condition, Environmental and Utility Data, MLK-011-300-CS-1980-0001 6 Topsides Structural Design Basis, MLK-011-300-CS-7880-0001 7 Hull Storage Tanks Technical Specification, MLK-011-200-CX-7771-0001 8 Datasheet for MEG Hull Storage Tank, MLK-011-200-CX-2180-0002

    1.3 MODELLING OF STRUCTURES

    The analysis is based on a three dimensional (3D) model generated by ANSYS. The model is further analysed by general packages FEA program ANSYS. The modelling procedures, boundary conditions and loading are described in this section together with detail results obtained from the FEA analysis.

    The completed Tank Structure T-5601A/B arrangement and dimension based on the sketch drawing attached are used to generate the detailed FEA model.

    The element type used is 3D tetrahedral with mid side node. The complete model is meshed with local refinement to achieve results with minimum error. The aspect ratio is maintained below 0.272. The generated of the meshing is shown in Figure 2.2.

    The bottom beam support level of tank are considered fully restraint (fixed support). For the support oval collar are considered displacement support on the support at top of the deck structure. ANSYS automatically calculates the self-weight of the modelled structure.

    The complete plots of loading and boundary condition are presented in Section 2.3.

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    4 OF 51

    1.3 STRENGTH OF MATERIALS

    Structural Materials: a) ASTM A36 or equivalent

    1. Yield Strength, Fy = 250 MPa

    2. Tensile Strength, Fu = 400 MPa.

    3. Modulus of Elastic, E = 205 kN/m2

    4. Poissons Ratio = 0.3

    5. Density = 7850kg/m3

    (Tank bottom beam W24x62)

    b) SA 240 or equivalent

    1. Yield Strength, Fy = 170 MPa

    2. Tensile Strength, Fu = 485 MPa.

    3. Modulus of Elastic, E = 197 kN/m2

    4. Poissons Ratio = 0.3

    5. Density = 8030kg/m3

    Following are the material using

    Table 1.3: Material for Structure Beam/Plate

    Item Description Material

    1 W24X62 ASTM A36

    2 WALL PLATE 12MM THK SA 240 SS 316L

    3 TOP OVAL PLATE 30MM THK SA 240 SS 316L

    4 WALL OVAL PLATE 24MM THK SA 240 SS 316L

    5 OVAL SUPPORT PLATE 25MM THK SA 240 SS 316L

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    5 OF 51

    Figure 1.3: Modelling for Tank T-5601 Structural Tank

    1

    2

    3

    4

    5

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    6 OF 51

    2.0 FEA ANALYSIS 2.1 INTRODUCTION

    The FEA analysis has considered the Hull MEG Storage Tank in its operational condition. The design has also accounted for the critical loading imposed onto the platform during operation in maximum and minimum loading conditions.

    The dead weight, content load, nozzle load and displacement loads were considered. Following are the condition load to be consideration:

    1) Operating Condition 2) Survival Condition 3) Extreme Condition

    2.2 DESIGN DATA

    (1) Reference: Global Performance Design Data for Topside Design

    MLK-011-200-CX-1380-0108/5886-200-CN-3832-108 Rev 02A

    (2) Summary of Acceleration at Point TS_SW : X = -33.91 m, Y = -33.91 m, Z = -35.25 m

    0 Degree Heading

    Heave Horizontal

    Operating 0.248 0.852

    Extreme 0.181 1.130

    Survival 0.247 1.502

    45 Degree Heading

    Heave Horizontal

    Operating 0.264 0.81

    Extreme 0.237 1.013

    Survival 0.288 1.342

    90 Degree Heading

    Heave Horizontal

    Operating 0.247 0.853

    Extreme 0.179 1.132

    Survival 0.248 1.504

    Acc (ms-2

    )

    Condition

    Condition

    Acc (ms-2

    )

    Condition

    Acc (ms-2

    )

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    7 OF 51

    2.2.1 OPERATING CONDITION

    MEG Tank (Operating Condition)

    1) Mass Calculation

    Tank Liquid Mass

    Volumn A

    L = 7.00 m

    B = 4.00 m

    H = 5.00 m

    N = 1.65 m

    Density 1092 kg /m3

    Mass = 152880 kg

    Vertical C.O.G from tank bottom = 2.50 m

    Volumn B (Not filled) 0 kg

    Tank Structure Mass 34950 kg

    Vertical C.O.G from tank bottom = 2.66 m

    Pump Mass 2000 kg

    Vertical C.O.G from tank bottom = 3.325 m

    Total Mass 189830 kg

    1862.232 kN

    Total Mass C.O.G = 2.54 m

    Volumn A

    Volumn B

    1.6

    5 m

    5.0

    m

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    8 OF 51

    2) TOC level Nozzle Reaction Load Calculation

    Horizontal :

    Fh acc = 61.8 kN or 30.9 kN per nozzle

    Vertical:

    Fv acc (Pump & Tank Structure)= 3.9 kN

    TOC Pressure Load Contributary Area = 14.0 m2

    Fv TOC Pressure Load 29.7 kPa = 70 kN (Nominal 5kPa)

    Total Fv = 73.9 kN or 37.0 kN per nozzle

    Bending Moment = 97.0 kN m or 48.5 kNm per nozzle

    3) Relative Deflection Between TOC and Deck 3 (from FE Analysis)

    Horizontal = 3.5 mm from global strength analysis

    Vertical = 5 mm from local model with full

    tank liquid but TOC with zero pressure load

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    9 OF 51

    Figure 2.2.1a: Structural tank Self weight

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    10 OF 51

    Figure 2.2.1b: Tank Liquid Mass

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    11 OF 51

    Figure 2.2.1c: Horizontal Nozzle Reaction

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    12 OF 51

    Figure 2.2.1d: Vertical Nozzle Reaction

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    13 OF 51

    Figure 2.2.1e: Moment Nozzle Reaction

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    14 OF 51

    Figure 2.2.1f: Vertical Displacement at Oval Support

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    15 OF 51

    Figure 2.2.1g: Horizontal Displacement at Oval Support

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    16 OF 51

    Figure 2.2.1h: Bottom Fixed Support

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    17 OF 51

    Figure 2.2.1j: Loading and Boundary condition

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    18 OF 51

    2.2.2 SURVIVAL CONDITION

    MEG Tank (Survival Condition)

    1) Mass Calculation

    Tank Liquid Mass

    Volumn A

    L = 7.00 m

    B = 4.00 m

    H = 5.00 m

    N = 1.65 m

    Density 1092 kg /m3

    Mass = 152880 kg

    Vertical C.O.G from tank bottom = 2.50 m

    Volumn B (Not filled) 0 kg

    Tank Structure Mass 34950 kg

    Vertical C.O.G from tank bottom = 2.66 m

    Pump Mass 2000 kg

    Vertical C.O.G from tank bottom = 3.325 m

    Total Mass 189830 kg

    1862.232

    Total Mass C.O.G = 2.54 m

    Volumn A

    Volumn B

    1.6

    5 m

    5.0

    m

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    19 OF 51

    2) TOC level Nozzle Reaction Load Calculation

    Horizontal :

    Fh acc = 109.0 kN or 54.5 kN per nozzle

    Vertical:

    Fv acc (Pump & Tank Structure)= 4.6 kN

    TOC Pressure Load Contributary Area = 14.0 m2

    Fv TOC Pressure Load 29.7 kPa = 415.8 kN (29.7kPa is based on minimum air

    gap water head above TOC in survival case)

    Total Fv = 420.4 kN or 210.2 kN per nozzle

    Bending Moment = 171.0 kN m or 85.5 kNm per nozzle

    3) Relative Deflection Between TOC and Deck 3 (from FE Analysis)

    Horizontal = 5 mm from global strength analysis

    Vertical = 5 mm from local model with full tank liquid

    but TOC with zero pressure load

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    20 OF 51

    Figure 2.2.2a: Structural tank Self weight

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    21 OF 51

    Figure 2.2.2b: Tank Liquid Mass

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    22 OF 51

    Figure 2.2.2c: Horizontal Nozzle Reaction

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    23 OF 51

    Figure 2.2.2d: Vertical Nozzle Reaction

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    24 OF 51

    Figure 2.2.2e: Moment Nozzle Reaction

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    25 OF 51

    Figure 2.2.2f: Vertical Displacement at Oval Support

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    26 OF 51

    Figure 2.2.2g: Horizontal Displacement at Oval Support

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    27 OF 51

    Figure 2.2.2h: Bottom Fixed Support

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    28 OF 51

    Figure 2.2.2j: Loading and Boundary condition

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    29 OF 51

    2.2.3 EXTREME CONDITION

    MEG Tank (Extreme Condition)

    1) Mass Calculation

    Tank Liquid Mass

    Volumn A

    L = 7.00 m

    B = 4.00 m

    H = 5.00 m

    N = 1.65 m

    Density 1092 kg /m3

    Mass = 152880 kg

    Vertical C.O.G from tank bottom = 2.50 m

    Volumn B (Not filled) 0 kg

    Tank Structure Mass 34950 kg

    Vertical C.O.G from tank bottom = 2.66 m

    Pump Mass 2000 kg

    Vertical C.O.G from tank bottom = 3.325 m

    Total Mass 189830 kg

    1862.232 kN

    Total Mass C.O.G = 2.54 m

    Volumn A

    Volumn B

    1.6

    5 m

    5.0

    m

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    30 OF 51

    2) TOC level Nozzle Reaction Load Calculation

    Horizontal :

    Fh acc = 82.0 kN or 41.0 kN per nozzle

    Vertical:

    Fv acc (Pump & Tank Structure)= 2.9 kN

    TOC Pressure Load Contributary Area = 14.0 m2

    Fv TOC Pressure Load 29.7 kPa = 70 kN (Nominal 5 kPa)

    Total Fv = 72.9 kN or 36.4 kN per nozzle

    Bending Moment = 128.7 kN m or 64.4 kNm per nozzle

    3) Relative Deflection Between TOC and Deck 3 (from FE Analysis)

    Horizontal = 4 mm from global strength analysis

    Vertical = 5 mm from local model with full tank liquid

    but TOC with zero pressure load

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    31 OF 51

    Figure 2.2.3a: Structural tank Self weight

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    32 OF 51

    Figure 2.2.3b: Tank Liquid Mass

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    33 OF 51

    Figure 2.2.3c: Horizontal Nozzle Reaction

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    34 OF 51

    Figure 2.2.3d: Vertical Nozzle Reaction

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    35 OF 51

    Figure 2.2.3e: Moment Nozzle Reaction

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    36 OF 51

    Figure 2.2.3f: Vertical Displacement at Oval Support

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    37 OF 51

    Figure 2.2.3g: Horizontal Displacement at Oval Support

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    38 OF 51

    Figure 2.2.3h: Bottom Fixed Support

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    39 OF 51

    Figure 2.2.3j: Loading and Boundary condition

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    40 OF 51

    3.0 FEA RESULTS 3.1 PLATE CENTRE STRESSES SUMMARY

    For detailed FE analysis the allowable stress based on the Von Misses criteria [1].

    Figure 3.1a: Von Misses Plot for Operating Cases

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    41 OF 51

    Figure 3.1b: Von Misses Plot for Survival Cases

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    42 OF 51

    Figure 3.1c: Von Misses Plot for Extreme Cases

    Allowable Strength for SA240 SS316L (Table 2A: ASME Stress Table) at Temperature 70C = 113 MPa----OK Allowable Strength for ASTM A36 (Table 2A: ASME Stress Table) at Temperature 70C = 134.03 MPa----OK

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    43 OF 51

    3.2 DEFLECTION PLOT

    Figure 3.2a: Deflection Plot Dir-X for Operating Cases

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    44 OF 51

    Figure 3.2b: Deflection Plot Dir-Y for Operating Cases

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    45 OF 51

    Figure 3.2c: Deflection Plot Dir-Z for Operating Cases

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    46 OF 51

    Figure 3.2d: Deflection Plot Dir-X for Survival Cases

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    47 OF 51

    Figure 3.2e: Deflection Plot Dir-Y for Survival Cases

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    48 OF 51

    Figure 3.2f: Deflection Plot Dir-Z for Survival Cases

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    49 OF 51

    Figure 3.2g: Deflection Plot Dir-X for Extreme Cases

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    50 OF 51

    Figure 3.2h: Deflection Plot Dir-Y for Extreme Cases

  • FEA ANALYSIS FOR HULL MEG STORAGE TANK T-5601A/B REV 01

    51 OF 51

    Figure 3.2j: Deflection Plot Dir-Z for Extreme Cases