2
Display 3 digit, 7 Segment display LED Indications Set point lock, Defrost, Relay ON, Alarm Input NTC Resolution 1 / 0.1° Setpoint 1 Indication Accuracy ±0.25% of Full scale ±1°C CH403A-1-NTC : 1) Main output : SPDT, 10A@250VAC/30V DC 2) Alarm output : SSR drive CH403A-2-NTC : 1) Main output : SPST, 20A@230VAC/30V DC CH403A-3-NTC : 1) Main output : SPDT, 10A@250VAC/30V DC 2) Alarm output : SPST, 5A@250VAC/30V DC Control Action ON-OFF Hysteresis 0.1 to 9.9 Alarm Modes High Alarm, Low Alarm, Door open mode Display Offset Adjustment -19.9 to 19.9 Reset Time Delay Adjustment from 0 to 19.9min Relay Action Heat & Cool mode Defrost Time Programmable from 00 to 99 minutes Defrost Frequency Programmable from 00 to 99min Sensor Type NTC probe Thermistor Range -40 to 100 C Nominal Resistance 10K ohms @ 25 C ° ° Supply Voltage CH403A-1-NTC : 230VAC@50/60Hz CH403A-2-NTC : 85 to 270VAC@50/60Hz CH403A-3-NTC : 230VAC@50/60Hz Power Consumption CH403A-1-NTC : 3VA maximum CH403A-2-NTC : 5VA maximum CH403A-3-NTC : 3VA maximum Temperature Operating: 0 to 50 -20 to 75 CH403A-1-NTC : 140 g CH403A-2-NTC : 130 g CH403A-3-NTC : 140 g °C(32 to 122°F) Storage: °C(-4 to 167°F) Humidity 95% RH(Non- condensing) Weight Supply Voltage Environmental Specifications NO COM 1 2 3 4 5 6 7 8 9 10 11 12 NC SENSOR N L DI COM NO (ALARM) NO COM SSR SSR 1 2 3 4 5 6 7 8 9 10 11 12 NC SENSOR N L DI + (ALARM) Terminal connections CH403A-1-NTC CH403A-3-NTC CH403A-2-NTC COM 1 2 3 4 5 6 7 8 9 10 11 12 NO SENSOR N L DI ! 2½ digit, 7 Segment display ! LED Status Indicator : Setpoint Lock, Defrost, Relay ON, Alarm ON ! ! ! ! ! °C /°F Selectable Defrost Management High & Low Temperature Alarm, Door Alarm, Sensor break Alarm, Door open alarm delay Compact Size Easy to use Features: Size : 36mm x 72mm Certification : Dimensions Display Input Specification Output Specification Functional Specification Specification for NTC Sensor

Features - GM electronic · 2018-02-19 · Display 3 digit, 7 Segment display LED IndicationsSet point lock, Defrost, Relay ON, Alarm Input NTC Resolution1 / 0.1° Setpoint 1 Indication

  • Upload
    others

  • View
    10

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Features - GM electronic · 2018-02-19 · Display 3 digit, 7 Segment display LED IndicationsSet point lock, Defrost, Relay ON, Alarm Input NTC Resolution1 / 0.1° Setpoint 1 Indication

Display 3 digit, 7 Segment display

LED Indications Set point lock, Defrost, Relay ON, Alarm

Input NTC

Resolution 1 / 0.1°

Setpoint 1

Indication Accuracy ±0.25% of Full scale ±1°C

CH403A-1-NTC : 1) Main output : SPDT, 10A@250VAC/30V DC

2) Alarm output : SSR drive

CH403A-2-NTC : 1) Main output : SPST, 20A@230VAC/30V DC

CH403A-3-NTC : 1) Main output : SPDT, 10A@250VAC/30V DC

2) Alarm output : SPST, 5A@250VAC/30V DC

Control Action ON-OFF

Hysteresis 0.1 to 9.9

Alarm Modes High Alarm, Low Alarm, Door open mode

Display Offset Adjustment -19.9 to 19.9

Reset Time Delay Adjustment from 0 to 19.9min

Relay Action Heat & Cool mode

Defrost Time Programmable from 00 to 99 minutes

Defrost Frequency Programmable from 00 to 99min

Sensor Type NTC probe

Thermistor Range -40 to 100 C

Nominal Resistance 10K ohms @ 25 C

°

°

Supply Voltage CH403A-1-NTC : 230VAC@50/60HzCH403A-2-NTC : 85 to 270VAC@50/60HzCH403A-3-NTC : 230VAC@50/60Hz

Power Consumption CH403A-1-NTC : 3VA maximumCH403A-2-NTC : 5VA maximumCH403A-3-NTC : 3VA maximum

Temperature Operating: 0 to 50

-20 to 75

CH403A-1-NTC : 140 gCH403A-2-NTC : 130 gCH403A-3-NTC : 140 g

°C(32 to 122°F)

Storage: °C(-4 to 167°F)

Humidity 95% RH(Non- condensing)

Weight

Supply Voltage

Environmental Specifications

NO COM

1 2 3 4 5 6 7 8 9 10 11 12

NC SENSOR NLDICOMNO

(ALARM)

NO COM SSR SSR

1 2 3 4 5 6 7 8 9 10 11 12

NC SENSOR NLDI+(ALARM)

Terminal connections

CH403A-1-NTC

CH403A-3-NTC

CH403A-2-NTC

COM

1 2 3 4 5 6 7 8 9 10 11 12

NOSENSOR NLDI

2½ digit, 7 Segment display

LED Status Indicator : Setpoint Lock, Defrost, Relay ON, Alarm ON

°C /°F Selectable

Defrost Management

High & Low Temperature Alarm, Door Alarm, Sensor break Alarm, Door open alarm delay

Compact Size

Easy to use

Features:

Size : 36mm x 72mm

Certification :

Dimensions

Display

Input Specification

Output Specification

Functional Specification

Specification for NTC Sensor

Page 2: Features - GM electronic · 2018-02-19 · Display 3 digit, 7 Segment display LED IndicationsSet point lock, Defrost, Relay ON, Alarm Input NTC Resolution1 / 0.1° Setpoint 1 Indication

Certification

CH403A-1-NTC

CH403A-2-NTC

CH403A-3-NTC

CH403A-1-NTC-CE

CH403A-2-NTC-CE

CH403A-3-NTC-CE

10A Relay ---

---

---

20A Relay

10A Relay

10A Relay

20A Relay

10A Relay

Sensor provided with product

Accessory(Also available separately on request)

Ordering Information

Category Standards Compliance

ESD Immunity Level III

Level II

Surge Immunity+/- 2 kV common mode, +/- 1 kV differential mode

Radiated SusceptibilityLevel III, 80 to 1000MHzLevel II, 1.4GHz to 2GHzLevel I, 2GHz to 2.7GHz

Conducted Susceptibility Level II

Voltage Dips andInterruptions

Conducted Emission

Radiated Emission

Electrical Fast Transient

IEC 61326-1

Applicable EMI / EMC standards

Product standard :

IEC 61000-4-2

IEC 61000-4-5

IEC 61000-4-3

IEC 61000-4-6

CISPR-11

CISPR-11

IEC 61000-4-4

IEC 61000-4-11

Dips : 0% residual voltage /1 cycle (Criteria B.),

40% residual voltage /10 cycles 50 Hz / 12 cycles 60 Hz (Criteria C)

70% residual voltage / 25 cycles 50 Hz / 30 cycles 60 Hz (Criteria C)

Interruptions : 0% residual voltage / 250 cycles 50 Hz / 300 cycles 60 Hz (Criteria C)