2
Nifty Feeding Cup is a reusable cup for feeding breast milk to newborns with breastfeeding difficulties. Caution: Reprocess the cup before first use and with each new infant. Refer to Reprocessing Instructions. Do not use the cup to administer medication. Express desired amount of breast milk in a clean Nifty cup. Gently squeeze the cup to fill the feeding reservoir. Ensure baby is in a semi-upright position with a supported head and neck. Bring the cup to baby’s mouth. Do not pour the milk into the mouth. Allow baby to actively feed from the reservoir at her own pace. Feeding reservoir Nifty Feeding Cup has been developed and designed through a collaboration between the University of Washington, Seattle Children’s Hospital, PATH and Laerdal Global Health. Design Collaboration Intended Use Use Specifications Reprocessing Instructions Symbol Definition Recyclable Intended to come in contact with food according to regulation 1935/2004 Not made with natural rubber latex Specifications Material Silicone rubber Volume 5 to 40 ml Mass Approx. 17 g Operating Temperature 0 °C to 50 °C (32 °F to 122 °F) Storage Temperature -20 °C to 70 °C (-4 °F to 158 °F) Laerdal Global Warranty Refer to the Laerdal Global Warranty for terms and conditions. For more information visit www.laerdal.com Nifty Feeding Cup User Guide EN www.laerdalglobalhealth.com 20-10385 Rev B © 2016 Laerdal Medical AS, All rights reserved. Laerdal® is a registered trademark of Laerdal Medical AS. Manufactured in China for: Laerdal Medical AS P .O. Box 377, Tanke Svilandsgate 30, 4002 Stavanger, Norway Tel : +47 51 51 17 00 Fax: +47 51 52 35 57 Email: [email protected] Printed in China www.laerdalglobalhealth.com STEP 1 1. Wash in a clean tray with clean water and mild soap. 2. Scrub the cup to remove milk and all other residue. 3. Rinse in clean water to remove soap residue. 4. Repeat above steps until clean. STEP 2 Perform one of the listed methods: a) Boiling b) Steam Autoclaving c) Chlorine (0.5%) 1. Use a fresh solution of 0.5% chlorine. 2. Immerse cup completely in the solution for 20 min. 3. Shake off and empty chlorine solution from the cup. 4. Rinse the cup thoroughly in clean water. 5. Repeat 3 times with fresh water to remove any chemical residue. STEP 3 1. Allow the cup to air dry in a protected space. 2. Inspect for damage and cleanliness/mineral deposits. 3. If damaged, remove cup from use. 100 °C (212 °F) 10 minutes. 136 °C (276 °F) 2.0 kg/cm 2 10-20 minutes Cat. no. 960-00133

Feeding Cup Nifty 3 4 STEP 3 - Laerdal Medical...4. Rinse the cup thoroughly in clean water. 5. Repeat 3 times with fresh water to remove any chemical residue. STEP 3 1. Allow the

  • Upload
    others

  • View
    4

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Feeding Cup Nifty 3 4 STEP 3 - Laerdal Medical...4. Rinse the cup thoroughly in clean water. 5. Repeat 3 times with fresh water to remove any chemical residue. STEP 3 1. Allow the

Nifty Feeding C

up is a reusable cup for feeding breast milk

to newborns w

ith breastfeeding difficulties.

Caution:

• Reprocess the cup before first use and w

ith each new

infant. Refer to Reprocessing Instructions. •

Do not use the cup to adm

inister medication.

Express desired amount of breast m

ilk in a clean Nifty cup.

Gently squeeze the cup to fill the feeding reservoir.

Ensure baby is in a semi-upright position w

ith a supported head and neck.

Bring the cup to baby’s mouth. D

o not pour the milk into

the mouth. A

llow baby to actively feed from

the reservoir at her ow

n pace.

Feeding reservoir

Nifty Feeding C

up has been developed and designed through a collaboration betw

een the University of

Washington, Seattle C

hildren’s Hospital, PATH

and Laerdal G

lobal Health.

Design C

ollaborationIntended U

se

Use

SpecificationsRe

proc

essin

g In

stru

ctio

ns

Symbol

Definition

Recyclable

Intended to come in contact w

ith food according to regulation 1935/2004

Not m

ade with natural rubber latex

Specifications

Material

Silicone rubber

Volume

5 to 40 ml

Mass

Approx. 17 g

Operating Tem

perature0 °C

to 50 °C

(32 °F to 122 °F)

Storage Temperature

-20 °C to 70 °C

(-4 °F to 158 °F)

Laerdal Global W

arrantyRefer to the Laerdal G

lobal Warranty for term

s and conditions. For m

ore information visit w

ww

.laerdal.com

Nifty

Feeding Cup

User G

uide

EN

ww

w.laerdalglobalhealth.com

20-10385 Rev B

© 2016 Laerdal M

edical AS, A

ll rights reserved.

Laerdal® is a registered tradem

ark of Laerdal Medical A

S.

Manufactured in C

hina for:Laerdal M

edical AS

P.O. Box 377, Tanke Svilandsgate 30, 4002 Stavanger, N

orway

Tel : +47 51 51 17 00

Fax: +47 51 52 35 57

Email: LG

H@

laerdal.com

Printed in China

ww

w.laerdalglobalhealth.com

STEP

1

1.

Was

h in

a c

lean

tra

y w

ith c

lean

wat

er a

nd m

ild s

oap.

2.

Scru

b th

e cu

p to

rem

ove

milk

and

all

othe

r re

sidue

.

3.

Rins

e in

cle

an w

ater

to

rem

ove

soap

res

idue

.

4.

Repe

at a

bove

ste

ps u

ntil

clea

n.

STEP

2Pe

rform

one

of t

he li

sted

met

hods

:

a) B

oilin

g

b) S

team

Aut

ocla

ving

c) C

hlor

ine

(0.5

%)

1.

Use

a fr

esh

solu

tion

of 0

.5%

chl

orin

e.

2.

Imm

erse

cup

com

plet

ely

in t

he s

olut

ion

for

20 m

in.

3.

Shak

e of

f and

em

pty

chlo

rine

solu

tion

from

the

cup

.

4.

Rins

e th

e cu

p th

orou

ghly

in c

lean

wat

er.

5.

Repe

at 3

tim

es w

ith fr

esh

wat

er t

o re

mov

e an

y ch

emic

al r

esid

ue.

STEP

3

1.

Allo

w t

he c

up t

o ai

r dr

y in

a p

rote

cted

spa

ce.

2.

Insp

ect

for

dam

age

and

clea

nlin

ess/

min

eral

dep

osits

.

3.

If da

mag

ed, r

emov

e cu

p fro

m u

se.

100

°C (

212

°F)

10 m

inut

es.

136

°C (

276

°F)

2.0

kg/c

m2

10-2

0 m

inut

es

12

4

12

ab

c3

oror

3

12

4

12

ab

c3

oror

3

12

4

12

ab

c3

oror

3

12

4

12

ab

c3

oror

3

12

4

12

ab

c3

oror

3

Cat. no. 960-00133

Page 2: Feeding Cup Nifty 3 4 STEP 3 - Laerdal Medical...4. Rinse the cup thoroughly in clean water. 5. Repeat 3 times with fresh water to remove any chemical residue. STEP 3 1. Allow the

1 2 4

1 2 a b c 3

or or

3

Nifty Feeding Cup

Boiling Steam Autoclaving Chlorine 0.5%