44
Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

Embed Size (px)

Citation preview

Page 1: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

Fermilab DC Cooler Experiences

Lionel Prost

MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling)

30 March 2015

Page 2: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

Outline

• Why Fermilab needed it

• Choice of the scheme

• Challenges, remedies and cooling optimization

• Operation

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences2

Page 3: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

3

Tevatron luminosity and antiprotons

• The Tevatron luminosity is almost linear with respect to the total number of antiprotons available for Tevatron stores. Increase of antiproton production and improvement of the beam quality was the central component of the Tevatron Run II.

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

0

50

100

150

200

250

300

350

400

450

0 100 200 300 400 500

Initi

al lu

min

osity

, 1030

cm-2

s-1

Number of antiprotons , 1010

Average initial luminosity as a function of the number of antiprotons injected into the Main Injector. Shown are the stores in 2011.

Page 4: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

4

Fermilab’s antiproton production chain

• Electron cooling in the Recycler Ring eliminated a bottleneck in the antiproton production chain.

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Nickel target

Proton beam 81012 protons every 2.2 sec120 GeV

Debuncher (stochastic cooling)

Accumulator (stochastic cooling)

8 GeV 8 GeV

1 TeV

Tevatron

150 GeV

Main injector

8 GeV

Recycler (stochastic and electron cooling)

31011 = 1108

p

41012 = 4109

p

1108 = 1

p 1108 = 300

p

until 200511012 p

Page 5: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

5

COOLER DESIGN SCHEME

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Page 6: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

6

Cooler’s features

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

• Electrostatic accelerator – 4 MeV 0.5 A = 2 MW DC

• Energy recovery; very low beam losses; overcoming high voltage discharges

• Novel transport scheme– Longitudinal magnetic field in the

cooling section and in the gun with lumped focusing in between

– 100 G in cooling section; 10 solenoids

• The solution allowed building the cooler with a modest budget and in time for Run-II

Design parameters of the RR ECoolEnergy

4.3 MeVBeam current (DC) 0.5

AmpsAngular spread

0.2 mrad Effective energy spread

300 eV

RR = Recycler Ring

• Primarily for longitudinal cooling – Required cooling times were

many minutes

Page 7: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

7

Transport with interrupted longitudinal magnetic field

• Longitudinal magnetic field in the cooling section and in the gun with lumped focusing in between

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Cathode Cooling sectionBeam line

Bz = 0R = 2 -10 mm

m

mc

eRB cathceff z

382 2

2

(normalized)

Bcz = 90 G

Rcath = 3.8 mm

mmc

TRcatht

2

2

(normalized)

Bcz = 105 G

Rbeam = 3.5 mm

mcs 7 (normalized)

• The transverse velocities in the cooling section can be low only if the magnetic fluxes through the emitter and the beam in the cooling section are equal.

• Outside of the field, the beam behavior is dominated by an effective emittance proportional to the magnetic flux through the emitter

Page 8: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

8

Applicability

• When is the scheme with interrupted magnetic field applicable?– The figure of merit is the magnetic flux through the beam in the

cooling section and the energy

– The scheme can work when the required beam radius and the magnetic field in the cooling section are low and the energy is high

• Cooling time required from RR Ecool is many minutes– Cooling is adequate without effects of strong magnetization

• Typical rms radius of the antiproton beam is 1-2 mm– Electron beam size can be similar

• Outside of the magnetic field, the (non-normalized) effective emittance is tolerable, ~4mm

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

2

, 2 22 2CS CS

B effe e

eB Re

m c m c

Page 9: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

9

Cooler in the Recycler Ring

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

1m

quadrupoles

1m SPB01 SPB02

YAG

BYR01

SPQ01

Portion of the Main Injector tunnel containing the cooling section and the “return” line.

The Pelletron and beam “supply” and “transfer” lines

20 m

February, 2005beginning of commissioning

Page 10: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

10

Some useful decisions

• Long off-line testing• Nominally “round” optics in the supply line• Zero dispersion in the cooling section• High dispersion after the cooling section to measure energy

drifts• Placement of elements with tuning convenience in mind

– Each solenoid is followed by dipole correctors and, after a drift space, by a BPM right upstream of the next solenoid

• Data logging of all parameters• Well–thought procedure of energy tuning• Initial transverse tuning with round orifices in the cooling

section (“scrapers”)

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Page 11: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

11

CHALLENGES, REMEDIES & COOLING OPTIMIZATION

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Page 12: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

12

Difficulties

• Magnetic fields from the Main Injector– Compensation of bus currents, additional

magnetic shielding– Changes in optics that made the system more

tolerable to the beam motion

• First energy matching– Absolute energy calibration of the electron beam

by measuring the electron Larmor wave length inthe magnetic field of the cooling section

– A special wide energy distribution of antiprotons toobserve the first interaction between beams

• Full discharges, stability of operation– Lots of work but not discussed here

• Energy stability– Temperature stabilization– Feedback from e-position in a high-dispersion region– “Peakiness” of the Schottky distribution after cooling

• Tuning, life time– See in following slides

3/30/2015Lionel Prost | Fermilab DC Cooler ExperiencesB

eam

Den

sity

(lo

g S

cale

)

Energy

Δp/p=3%

One of the first indications of interaction between antiprotons and electrons.

More later on

Page 13: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

13

Drag rates and cooling rates

• Drag rate measurements– Probing properties of the electron beam with a “pencil”

antiproton beam– Rely on a sensitivity of the longitudinal cooling on electron

angles and density, – Extensively used for tuning

• Cooling rates– Conditions are close to operational– E-beam is turned off to let antiproton distribution diffuse and

then turned back on. A cooling rate is determined as a difference in time derivatives of an emittance or momentum spread between these two modes.

– Used to quantify operational properties of the cooler as well as an additional study tool

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Page 14: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

14

Drag rate measurements

• Coasting “pencil” antiproton beam (Np~1×1010); changes in average momentum are recorded after a jump of electron energy; drag rate = time derivative of the average momentum

• Drag rate ≈ longitudinal cooling force for an “average” particle

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

0.0

0.2

0.4

0.6

0.8

1.0

1.2

0.0

0.5

1.0

1.5

2.0

2.5

3.0

3.5

4.0

0 5 10 15 20

s[M

eV/c]

Dis

trib

ution

mea

n [M

eV/c

]

Time [min]

Example of evolution of the mean and rms values of the momentum distribution after a 1.9 keV e-energy jump . The drag rate is 71 (MeV/c)/hr. Ie= 0.5 A.

Page 15: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

15

Cooling force as a function of the beam current

• In all measurements, the voltage jump was 2 kV and the electron beam was “on axis”. All points in each curve are taken at constant focusing settings

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

0

10

20

30

40

50

60

70

80

90

100

0 100 200 300 400 500

Dra

g ra

te [M

eV/c

per

hou

r]

Electron beam current [mA]

2/1/2006 6/13/2006 11/01/2006 12/06/2007 6/8/2010 1/2/2011

Page 16: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

16

Cooling force as a function of the beam current

• At low beam currents, main improvements came from– Alignment of the field in the cooling section– Adjustment of quadrupole focusing

• All adjustments were made at Ie = 0.1A 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

0

10

20

30

40

50

60

70

80

90

100

0 100 200 300 400 500

Dra

g ra

te [M

eV/c

per

hou

r]

Electron beam current [mA]

2/1/2006 6/13/2006 11/01/2006 12/06/2007 6/8/2010 1/2/2011

Page 17: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

17

Cooling section field alignment

• Procedure: Optimize 10 pairs of correctors in each module measuring the cooling force produced by the module.– Tilt or shift of the solenoid results in

dipole fields similar to fields generated with either 8 pairs of central correctors or 2 pairs of end correctors

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

BPMs Solenoid modules

Electron beam trajectory Ideal trajectory

BPMs Solenoid modules

Electron beam trajectory Ideal trajectory

BPMs Module to be measuredElectron beam trajectory

IIIIII III

The cooling section consists of 10 identical modules, which are rigid but can move with respect to one another due to tunnel deformations, hence creating field errors.

I. Area being measuredII. Transition area (large angle)III. Large offset (4 mm with the electron beam radius

~2.3 mm)

0

0.5

1

1.5

2

2.5

3

-0.4 -0.3 -0.2 -0.1D

rag

Rat

e, M

eV/c

/hr

CXC21I, A

Drag rate as a function of a change in currents of all 8 central X correctors by the same amount in module #3.

Page 18: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

18

Adjustments of focusing

• There were several indications of large focusing errors – In part, drag rates measured across the beam were dropping with the offset

much faster than the calculated electron beam density

• Beam imaging at a YAG scintillator showed a large ellipticity – Could be corrected with quadrupoles– YAG pulse mode, where focusing was different from DC

• Could not use it for an effective DC tuning

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Quadrupoles

YAG location

2 1

3 4

Images of the beam with zero (1 and 2) and optimized (3 and 4) quadrupole currents.Ie ~ 0.1A, 2µs pulse.

Page 19: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

19

Adjustments of focusing (cont.)

• Tuned quadrupoles based on the drag rate measurements (off-axis)– Maximizing the drag rate for each of 6 quadrupoles

• Cooling rates increased by ~1.5 times longitudinally and by ~2 times transversely (at Ie = 0.1A)

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

0

0.5

1

1.5

2

2.5

3

1.6

1.9

2.2

2.5

2.8

3.1

3.4

0 0.05 0.1 0.15 0.2 0.25 0.3 0.35 0.4 0.45 0.5

<9

0%

,n >, m

m m

rad

Be

am

curre

nt ,

10

2mA

RM

S m

om

en

tum

sp

rea

d, M

eV

/c

Elapsed time, hour

Typical cooling rate measurement (October 26, 2007) .Ie ~ 0.1A, beam on axis, focusing settings include quadrupoles.Transverse emittances measured with flying wires.

012345678

0 1 2 3 4

Offset, mm

dP

/dt,

Me

V/c

/hr

1 2

Longitudinal cooling rates at various vertical offsets of the electron beam before (set 2) and after (set 1) adjustments of quadrupoles. Ie ~ 0.1A.

Page 20: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

20

Improvements at high beam current

• At higher beam currents, the main improvement came from ion clearing

• Tuning was made mainly at Ie = 0.3A

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

0

10

20

30

40

50

60

70

80

90

100

0 100 200 300 400 500

Dra

g ra

te [M

eV/c

per

hou

r]

Electron beam current [mA]

2/1/2006 6/13/2006 11/01/2006 12/06/2007 6/8/2010 1/2/2011

Page 21: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

21

Ions - Effect

• While at Ie= 0.1A the drag rates drops with offset smoothly, atIe= 0.3A there are three narrow areas of good cooling

• Hypothesis: the reason is a highly non-linear focusing effect of ions• Proposed remedy: clear ions by interrupting the electron current for a

microsecond– In the beam electric field, the ions gain a high transverse velocity

(Wi ~10 eV) to reach the wall in ~1 µs after turning the beam off.

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Contour plots of drag rates. Left - Ie = 0.3A,

Right - Ie = 0.1A.

Contour levels are in MeV/c/hr.

Page 22: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

22

Ions - Removal

• The capability to interrupt the beam for 2 – 20 µs at frequencies up to 100 Hz was implemented

• Strong dependence of drag rates on the interruption frequency– Naturally, the rate is maximum where it had been optimized– Duration of the interruptions doesn’t have any measurable effect

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

0 5 10 15 2020

25

30

35

Frequency, Hz

Dra

g ra

te, M

eV/c

/hr

0 10 20 30 4025

30

35

40

Frequency, Hz

Dra

g ra

te, M

eV/c

/hr

Drag rate as a function of the interruption frequency for Ie = 0.3 A (left) and 0.1 A (right). The interruption length was 2 µs; beams were on axis. The squares represent the data, and the solid lines are fits. Focusing was optimized at 15 Hz for 0.3 A and with no interruptions for 0.1A (January 26, 2010).

Page 23: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

23

Cooling with ion clearing

• While cooling improved significantly, we couldn’t use it to its full strength in operation because of an antiproton instability. – Also, the beam trips are more frequent at higher electron currents

– In 2011, we used Ie = 0.2 A and ion clearing in the time of beam preparation for Tevatron shots

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

0

2

4

6

8

10

12

14

16

18

20

0 1 2 3 4 5 6

Coo

ling

Rat

e [M

eV/c

/hr]

FW Emittance (95%, n) [π· mm ·mrad]

100 mA 300 mA w/o ion clearing 300 mA with ion clearing

Quads adjustment

Field alignment

Ion clearing

Longitudinal cooling rate measured in 2006-2010. The arrows connect points measured on the same day to show the range of several improvements. All measurements are “on axis”.

Contour plot of drag rates with ion clearing.Ie =0.3A, 100 Hz. Contour levels are in MeV/c/hr.

Page 24: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

24

Summary of cooling improvements

• Tuning of focusing with quadrupoles• Alignment of the magnetic field in the cooling section• Ion clearing

• All improvements of cooling properties were made through decreasing the transverse electron velocities (angles) in the cooling section– The main study tool was the drag rate measurements– The total rms angle is decreased probably by 1.5 – 2 times

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

0 5 10 15 200

20

40

60

Momentum offset, MeV/c

Dra

g fo

rce,

MeV

/c/h

r

.

Drag rate as a function of momentum offset. Ie = 0.1A, focusing is optimized for ion clearing, 100 Hz. The circles are data, and the solid line is a calculation with θt = 80µrad, δWe = 200eV, Lc = 9. January 4, 2011.

21 2

0 20 2

2

( )

pp

p u

lz p

p

e uF p F du

pu

p

1

22

4

0 2 2 3 2

2

2

42

pe

e

t p

el c

t e

Mp W

m c

p cM

n e LF

m c

θt - electron angle,

δWe – energy spread

Page 25: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

25

OPERATION

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Page 26: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

26

Recycler cooling cycle

• Efficient storage of antiprotons and cooling them for shots to the Tevatron– Typical beam loss due to the finite life

time in the Recycler is ~5%– Number of stored antiprotons is up to

6·1012 with a life time > 300 hrs– Phase density at extraction is limited

by an instability

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

0

100

200

300

400

500

15 20 25 30

Number of antiprotons, 1010

0

50

100

150

200

15 20 25 30

Longitudinal 95% emittance, eV·s

0

2

4

6

8

10

12

14

15 20 25 30

Time, hours

Transverse emittance (H+V)/2 (95%, n),µm

Typical cycle of accumulation of antiprotons in the Recycler ring and following extraction. June 17-18, 2011. Electron beam was kept at 0.1A , shifted by 2 mm from the axis except right before extraction, when it was switched to 0.2A in ion clearing mode and moved on axis. Average life time was 256 hours.

Page 27: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

27

Cooling

• July 9, 2005 – First indication of the cooling force

• The cooler’s performance was significantly improved and optimized – Procedures for tuning, feedback loops, automation…– Optimization of the cooling scenario

• Cooling off – axis• Cooling with a helical trajectory• Increasing the electron beam current for

final cooling before extraction

• Significant efforts for maintenance– When the cooler was ‘broken’, the rate of

integrating luminosity was dropping by ~3

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Electron beam“On axis”

2 mm offset

~95% of antiprotons

Page 28: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

28

Availability/Reliability

• Pelletron ran 24/7 and was turned off only when either a component had failed or during planned shutdowns (~once a year)– Beam ‘interruptions’ (short)

• Beam trips:– Protection system turns off the beam if a drop of HV by >5 kV or other

problem is detected– < 1 trip per day– ~20 s to recover

• Full discharges:– Unprovoked: ~once a year– 1-3 hours to fully recover

– Failures (long down time)• The worst situation is to have to go into the Pelletron tank

– 8-10 hrs to open, 6-8 hrs to close• Typical turn-around time ~ 36 hrs

– Normally, several accesses per year• Mostly, to repair electronics

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Page 29: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

29

Electron beam energy drift

• Electron energy drift– Corrected with a feedback loop based on BPM reading in a high-dispersion

area– Adjustments to an ‘energy parameter’ based on the Schottky longitudinal

distribution profile

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

-4000

-3000

-2000

-1000

0

1000

2000

0 5 10 15 20 25 30

BPM #

Dis

per

sio

n, m

m

X Y

0.0

1.0

2.0

3.0

4.0

5.0

6.0

7.0

8.0

-6 -4 -2 0 2 4 6

Momentum offset, MeV/cP

art

ilce

de

ns

ity

, arb

. un

its

Optim um +1.2 kV shift

Measured dispersion in the electron beam line. The horizontal axis shows the BPM number counted along the beam line. Reading of the vertical channel of the first BPM after the 180 deg bend deviates with the energy change as 0.33 mm/keV.

Equilibrium momentum distribution of antiproton beam for cooling at two electron energies. Blue-optimum energy tuning, red - the electron energy is shifted by 1.2 keV; electron beam is on axis.

Page 30: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

30

Impedance-driven instability (transverse)

• Due to own space charge of pbars when deeply cooled– Dampers suppressed them very efficiently– A few were observed during extraction process

• Complicated RF gymnastics

• Defined a ‘phase density’ parameter– Monitored on-line– Kept far from the calculated (and experimentally

determined) instability threshold

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Vertical damper kick [%]

40 min

Number of pbars [e10]

Horizontal emittance (n, 95%) [p mm mrad]

Vertical emittance(n, 95%) [p mm mrad]

Vertical damper kick [%]

Horizontal damper kick [%]

Electron beam current (0.1 A)

~20e10 loss

~10 s

Instability before extracting bunch #7

9595 95

P

L T n

ND

# of pbar 1010

Emittances in eV∙s & mrad

pantiproton ≡ ≡ pbar

Page 31: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

31

Life time

• Life time was always worse with the electron beam on than without it– Vacuum limit with stochastic cooling: ~1000 hrs– In operation with electron cooling; 100 – 500 hrs– No comprehensive explanation, but likely the main effect is related to

formation of a cold core • Life time might be decreasing even when transverse emittance was shrinking• Strongest correlation was with the peak antiproton beam current

– Some electron beam –induced diffusion is possible as well

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

• Observation that might be relevant: Life time of protons in RR was dropping from tens of hours to seconds if the electron beam was on

• Life time improvements:– “Off-axis” cooling– Cooling with a helix trajectory

0

200

400

600

800

1000

1200

1400

0 20 40 60 80 100 120

!hr

Life

tim

e, h

r

Peak current, mA

a

Example of dependence of the antiproton life time at equilibrium on peak current of the antiproton beam. Dec 2, 2008 – Jan 7, 2009. Ie = 0.1A.

Page 32: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

32

Summary of lessons learned

• Procedure of the beam line tuning needs to be thought ahead and taken into account while placing components– Both for initial tuning and operation

• Alignment of a 20-m cooling section can be significantly affected by ground motion

• Ions need to be carefully cleared from a relativistic electron beam

• Life time of the cooled beam may decrease with electron cooling

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Page 33: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

33

Final words

• Unique electron cooler– High energy (4 MV), huge beam power (2 MW)– Low magnetic field in the cooling section with lumped focusing

outside• ‘Non-magnetized’ cooling• Transport of a beam with large effective emittance

• Reliable machine running 24/7

• The Recycler Electron Cooler significantly contributed to the success of Run-II– i.e. property of cooling and overall operation of the cooler

satisfied the needs (and maybe beyond expectations)

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Page 34: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

34 3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

• For more information:– A. Shemyakin and L. R. Prost, The Recycler Electron

Cooler, arXiv:1306.3175– S. Nagaitsev, L. Prost and A. Shemyakin, Fermilab 4.3 MeV

electron cooler, JINST 10 T01001 (2015), arXiv:1411.6994

References

Page 35: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

35

BACK-UP SLIDES

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Page 36: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

36

Choice of the scheme (I)

• Based on SSC MEB proposal for relativistic cooling– No longitudinal magnetic field at the gun– Lumped focusing in the cooling section

• Pros– Use of industrially-manufactured electrostatic accelerator– Cooling section simpler than for strong continuous focusing

• Significantly cheaper too

• Cons– Low transverse velocities in cooling section large value of the b-

function susceptible to perturbations• Drift instability from wall image charges• Ion instability

– Ineffective cooling inside the lenses• Large azimuthal velocity

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Page 37: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

37

Choice of the scheme (II)

• Combine advantages from longitudinal magnetic field in the cooling section and lumped focusing in the transport lines

• The main reason: the scheme without continuous longitudinal magnetic field looked doable in the time frame useful for the Tevatron Run II.Also, – Pelletrons have had the terminal potential up to 25 MV

• Known for being reliable machines

– Cheaper– Easier to incorporate into the existing MI/RR tunnel

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Page 38: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

38

Beam recirculation

• Initially, insufficient stability main obstacle during R&D and early commissioning

• Remedies:– Increase total length of acceleration tubes

• 5 MV nominal → 6 MV nominal

– Fast protection circuitry

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Fast CPO signal

Electron beam is shut off

Pelletron voltage stops decreasing

Current transformer signal

Voltage drop limit

< 1 s

5 kV-25

0

25

50

75

100

125

150

175

-0.04 -0.02 0.00 0.02 0.04 0.06 0.08 0.10 0.12 0.14

Time [ms]

dU

0 [k

V]

'Slow' discharge 'Fast' discharge 'Slow' discharge (2)

Oscillograms of ‘fast’ (red) and ‘slow’ (blue) discharges recorded by the fast capacitive pickup (Fast CPO) that measures the terminal voltage ‘drop’ (the terminal voltage actually becomes more positive)

Oscillograms of a recirculation interruption, showing the effectiveness of the fast gun shut off

Page 39: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

39

Beam recirculation ‘remedies’: Gun and Collector

• Developed gun and collector allowed a high beam current with low loss. The best results:– At a low-energy test bench: 2.6 A, relative beam loss 2·10-6

– 4.3 MeV beam, short beam line: 1.8 A, relative beam loss 1.2·10 -5 – 4.3 MeV beam, full beam line: 0.6 A, relative beam loss 1.6·10 -5

• The likely reasons for the higher beam loss with the longer beam lines are interaction with the residual gas and the energy spread increase due to IBS

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

-2

-1.75

-1.5

-1.25

-1

-0.75

-0.5

-0.25

0

0

5

10

15

20

25

30

35

40

0 0.1 0.2 0.3 0.4 0.5 0.6 0.7

Tube current [m

A]

Ano

de c

urre

nt [

mA

]

Beam current [A]

Anode current Deceleration tube current

Anode current and changes in the deceleration tube current as functions of the beam current. Full line; ion clearing mode (December 31, 2011.).

Pelletron HV Terminal

Gun

Collector

Page 40: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

40

Beam recirculation ‘remedies’: Beam optics• Adjust beam envelope in deceleration tube to transport out electrons coming out

of the collector• Adjust beam envelope in acceleration tube so that beam core remains far from

the tube electrodes when the beam trips– Big difference in the occurrence of full discharges originating in the acceleration

tube.

• Protection of deceleration tube from irradiation when the beam trips by using optics with high dispersion in the return line

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

0

2

4

6

8

10

12

0 500 1000 1500 2000 2500 3000 3500 4000

Z [mm]

R [

mm

]

Ua = 20 kV (I = 0.7 A) Ua = 10 kV (I = 0.18 A)

Bg lens = 0.6 ABg sol = 3 ASPA01I = 4 ASPA02I = 3 ASPA03I = 5 ASPA04I = 5 ASPA05I = 5 A

Simulations of the beam envelope (edge) in the accelerating column for nominal settings (solid curve) and settings representing a partial discharge (dotted curve). The limiting aperture is 12 mm. Vertical dotted lines represent the locations of the magnetic lenses.

Page 41: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

41

Energy drift

• Temperature – related– Pelletron temperature– GVM preamplifier temperature

• Caused by changing balance ofcurrents– Chain current variation

• Was a problem in the time ofcharging efficiency degradation

– Variation of the beam loss or corona current

• Changes in GVM reading associated with SF6 permittivity

– At ~6 atmospheres (abs) eSF6 = 1.012

– The charge generated on GVM at a given voltage increases correspondingly

– 1% SF6 pressure increase results at the same terminal voltage in the GVM reading increase by about 0.01%

• Results in 0.5 keV/psi energy drop

• Was noticed in the time of an SF6 leak3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Example of electron beam energy drift after turning the Pelletron on. Traces: energy deviation (2keV/div); SF6 temperature (5 K/div); GVM reading (2kV/div), and temperature of the GVM preamplifier(2 K/div).

Page 42: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

42

Contribution of residual gas ions

• At Ie = 0.1A, the potential difference between the beam center and the vacuum pipe is ~ 15 V. It is a deep well for thermal-energy ions(Wi ~ 0.03 eV) created by the primary electrons.

• Focusing effect from the ions is higher than the defocusing effect from the beam space charge by ~hcg2 , and can be large with g2 ≈100

– Simulations at optimized focusing: Da = k·r·DIe with k ~1 rad/A/m

– Neutralization hc needs to be kept <1% at all relevant currents

– Calculated time to reach hc ~1% is ~0.2s.

• H2 at 0.3 nTorr

• Each BPM is used for ion clearing– One of the plates is biased at -300V while the other is grounded

• Thermal ions fly ~5m distance between BPMs in the supply line in ~ 3ms

• However, there are barriers for ions created by– Size variations of both the electron beam and the vacuum pipe– Solenoidal lenses– BPM clearing removes ions to ~2% (from fitting to measurements)

• Still not good enough

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Page 43: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

43

Angles in the cooling section

• Estimations of angles in the cooling section for the best case. – Ie = 0.1 A. 1D values are shown.

• Difficult to come up with a defendable procedure of summation

• Agrees with cooling force measurements3/30/2015Lionel Prost | Fermilab DC Cooler Experiences

Effect Angle, µrad Method of evaluation Thermal velocities

57 Calculated from the cathode temperature

Envelope mismatch

~50 Resolution of tuning and simulations

Dipole motion (above 0.1 Hz)

~35 Spectra of BPMs in the cooling section

Cool. Sec. field imperfections

~50 Magnetic field measurements and tracking

Non-linearity in lenses

~20 Trajectory response measurements

Ion background < 10 Cooling measurements

Total ~100 Summed in quadratures

Page 44: Fermilab DC Cooler Experiences Lionel Prost MEIC Collaboration Meeting Spring 2015 (Topics: Ion Beam Formation and Cooling) 30 March 2015

44

Example: Oct’07-Oct’08

• HV was on 92% of the time– Part of the downtime was not related to ECool problems– 5 cases of HV regulation–related problems caused ~130 hours

of downtime• Continuing issue with GVM• Near the end of the run, much less frequent

– The next source of the downtime was the control system• Interaction between NEC’s ACCELNET and Fermilab’s ACNET

– Eventually, mostly resolved but not 100% free of hang-ups

3/30/2015Lionel Prost | Fermilab DC Cooler Experiences