5
Copyright © 2020 White Knight Fluid Handling | A Graco company P: 435.783.6040 | info@wkfluidhandling.com | https://wkfluidhandling.com engineer approvedVersion: 2.0.3 | Published: 20 Oct 2020 | P. 1 Specifications subject to change without notice FHA FILTER HOUSINGS 44 1.7 44 1.7 453 17.8 481 18.9 227 8.9 245 9.6 90 3.5 97 3.8 10 in. 20 in. FHA housings fit Code 0 filter cartridges and sizes offered by major suppliers. Filter Sizing High-Purity Compact Multi-Chamber Filter Housings FHA Series dual-chamber and quad-chamber filter housings fit standard filter cartridges from major suppliers. They provide high flows in PTFE/PFA fluid paths with reliable dual-static crush seals that can be retightened. These compact filter housings eliminate additional plumbing and welding, and offer various fitting options. https://wkfluid.com/fha/ Advanced Technologies Compatible with Code 0 filter cartridges • Nonmetal PTFE/PFA liquid paths • Compact layouts with configurable fitting locations, sizes and types Filters in parallel or series operation Up to 3.2-in filter diameters for greater filtration surface area • Eliminate welds and excess plumbing to reduce costs, save time, save space, and remove leak points • Easy to configure, install and service • Compact, durable design with minimal parts • Leak-free dual-static crush seals Low pressure drop (1-in flow path) Max pressure at 25°C is 7 Bar, 100 psi Max pressure at 100°C is 3 Bar, 45 psi Features & Benefits Reliable double O-ring seals Compact layouts reduce footprint Adjustable seals Greater filtration surface area with up to 3.2-in diameter filters Low pressure drop Easy to install Eliminates additional plumbing and welding Various fitting options Two O-rings in an angled load system ensure reliable seals to prevent leaks. Sealing pressure can be adjusted beyond initial compression loads. Dual-Static Crush Seal UP TO 7 BAR / 100 PSI UP TO 7 BAR / 100 PSI RECIRC. / DELIVERY RECIRC. / DELIVERY ULTRA HIGH ULTRA HIGH PURITY PURITY UP TO 100˚C 212˚F UP TO 100˚C 212˚F TEMPERATURE TEMPERATURE Compatible with Code 0 filters

FHA Filter HOusinGs - White Knight Fluid Handling · liquid inlet Pre-Filter Vent/Drain Post Filter Vent/Drain Compare to traditional filter housings 2-Chamber Parallel Filter Housing

  • Upload
    others

  • View
    7

  • Download
    0

Embed Size (px)

Citation preview

  • Copyright © 2020 White Knight Fluid Handling | A Graco companyP: 435.783.6040 | [email protected] | https://wkfluidhandling.com

    engineer approved™

    Version: 2.0.3 | Published: 20 Oct 2020 | P. 1Specifications subject to change without notice

    FHA Filter HOusinGs

    441.7

    441.7

    45317.8

    48118.9

    2278.9

    2459.6

    903.5

    973.8

    10 in. 20 in.

    FHA housings fit Code 0 filter cartridges and sizes offered by major suppliers.

    Filter sizing

    High-Purity Compact Multi-Chamber Filter HousingsFHA Series dual-chamber and quad-chamber filter housings fit standard filter cartridges from major suppliers. They provide high flows in PTFE/PFA fluid paths with reliable dual-static crush seals that can be retightened. These compact filter housings eliminate additional plumbing and welding, and offer various fitting options.

    https://wkfluid.com/fha/

    Advanced technologies

    • Compatible with Code 0 filter cartridges • Nonmetal PTFE/PFA liquid paths• Compact layouts with configurable

    fitting locations, sizes and types• Filters in parallel or series operation• Up to 3.2-in filter diameters for

    greater filtration surface area• Eliminate welds and excess

    plumbing to reduce costs, save time, save space, and remove leak points

    • Easy to configure, install and service

    • Compact, durable design with minimal parts

    • Leak-free dual-static crush seals • Low pressure drop (1-in flow path)• Max pressure at 25°C is 7 Bar, 100 psi

    Max pressure at 100°C is 3 Bar, 45 psi

    Features & Benefits

    Reliable double O-ring seals

    Compact layouts reduce footprint

    Adjustable seals

    Greater filtration surface areawith up to 3.2-in diameter filters

    Low pressure drop

    Easy to install

    Eliminates additional plumbing and welding

    Various fitting options

    Two O-rings in an angled load system ensure reliable seals to prevent leaks. Sealing pressure can be adjusted beyond initial compression loads.

    Dual-static Crush seal

    UP TO 7 BAR / 100 PSIUP TO 7 BAR / 100 PSI

    RECIRC. / DELIVERYRECIRC. / DELIVERY

    ULTRA HIGHULTRA HIGH

    PURITYPURITY

    UP TO

    100˚C212˚F

    UP TO

    100˚C212˚F

    TEMPERATURETEMPERATURE

    Compatible with Code 0 filters

  • Copyright © 2020 White Knight Fluid Handling | A Graco companyP: 435.783.6040 | [email protected] | https://wkfluidhandling.com

    Version: 2.0.3 | Published: 20 Oct 2020 | P. 2Specifications subject to change without notice

    FHA series Filter Housingsengineer approved™

    28911.4

    1455.7

    321.3

    58122.9

    652.6

    34513.6

    321.3

    1505.9

    321.3

    39315.5

    37014.6

    Dimensions in [mm] inchesFHA-02-P Dimensions

    Dual-Chamber Parallel (FHA-02-P)

    liquid Outlet

    liquid inlet Pre-Filter Vent/Drain

    Post Filter Vent/Drain

    Compare to traditional filter housings

    2-Chamber Parallel Filter Housing

    FHA-02 traditional 2-Chamber Parallel Filter Housing

    Wrench tighten

    Fluid goes through all chambers simultaneously greatly reducing pressure drop.

    Traditional Parallel Housing Dimensions for Comparison

    https://wkfluid.com/fha/

  • Copyright © 2020 White Knight Fluid Handling | A Graco companyP: 435.783.6040 | [email protected] | https://wkfluidhandling.com

    Version: 2.0.3 | Published: 20 Oct 2020 | P. 3Specifications subject to change without notice

    FHA series Filter Housingsengineer approved™

    Traditional Parallel Housing Dimensions for Comparison

    Dimensions in [mm] inchesFHA-04-P Dimensions

    Quad-Chamber Parallel (FHA-04-P)

    4-Chamber Parallel Filter Housings

    Fluid goes through all chambers simultaneously greatly reducing pressure drop.

    Wrench tighten

    FHA-04Four traditional Housings in Parallel

    liquid Outlet

    Pre-Filter Vent/Drain

    liquid inlet

    Post Filter Vent/Drain

    69227.2

    39315.5

    28911.4

    28911.4

    58122.9

    37714.8

    321.3

    652.6

    1505.9

    2369.3

    Compare to traditional filter housings

    https://wkfluid.com/fha/

  • Copyright © 2020 White Knight Fluid Handling | A Graco companyP: 435.783.6040 | [email protected] | https://wkfluidhandling.com

    Version: 2.0.3 | Published: 20 Oct 2020 | P. 4Specifications subject to change without notice

    FHA series Filter Housingsengineer approved™

    Traditional In-Line Housing Dimensions for Comparison

    Dimensions in [mm] inchesFHA-02-s Dimensions

    Dual-Chamber series/in-line (FHA-02-s) Compare to traditional filter housings

    2-Chamber Series Filter Housing

    two traditional Housings in series

    Wrench tighten

    Fluid goes through first chamber and then through an additional chamber, which increases filtration and reduces pressure drop.

    FHA-02

    28911.4

    1455.7

    321.3

    34513.6

    58122.9

    642.5

    1505.9

    321.3

    37714.9

    1576.2

    liquid Outlet

    liquid inlet Pre-Filter Vent/Drain Post Filter Vent/Drain

    intermediate Filter Vent/Drain

    https://wkfluid.com/fha/

  • Copyright © 2020 White Knight Fluid Handling | A Graco companyP: 435.783.6040 | [email protected] | https://wkfluidhandling.com

    Version: 2.0.3 | Published: 20 Oct 2020 | P. 5Specifications subject to change without notice

    FHA series Filter Housingsengineer approved™

    Traditional In-Line Housing Dimensions for ComparisonDimensions in [mm] inches

    FHA-04-s Dimensions

    Quad-Chamber series/in-line (FHA-02-s)Compare to traditional filter housings

    4-Chamber Series Filter Housing

    FHA-04

    Four traditional Housings in series

    Wrench tighten

    Fluid flows through first two chambers and then through the next two chambers, which increases filtration and reduces pressure drop.

    28911.4

    28911.4

    321.3

    642.5

    58122.9

    34513.6

    1505.9

    321.3

    59023.2

    36514.4

    liquid Outlet

    liquid inlet Pre-Filter Vent/Drain Post Filter Vent/Drain

    intermediate Filter Vent/Drain

    https://wkfluid.com/fha/