Copyright © 2012 by Ceragon Networks Ltd. All rights reserved. d FibeAir® IP-10C Installation Guide Document ID: DOC-00032280 Rev. H October 2012

FibeAir IP-10C Installation Guide_RevH

Embed Size (px)

Citation preview

Page 1: FibeAir IP-10C Installation Guide_RevH

Copyright © 2012 by Ceragon Networks Ltd. All rights reserved.

d

FibeAir® IP-10C Installation Guide

Document ID: DOC-00032280 Rev. H

October 2012

Page 2: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 2 of 63

Notice

This document contains information that is proprietary to Ceragon Networks Ltd. No part of this publication may be reproduced, modified, or distributed without prior written authorization of Ceragon Networks Ltd. This document is provided as is, without warranty of any kind.

Registered Trademarks

Ceragon Networks® is a registered trademark of Ceragon Networks Ltd. FibeAir® is a registered trademark of Ceragon Networks Ltd. CeraView® is a registered trademark of Ceragon Networks Ltd. Other names mentioned in this publication are owned by their respective holders.

Trademarks

CeraMap™, PolyView™, EncryptAir™, ConfigAir™, CeraMon™, EtherAir™, and MicroWave Fiber™, are trademarks of Ceragon Networks Ltd. Other names mentioned in this publication are owned by their respective holders.

Statement of Conditions

The information contained in this document is subject to change without notice. Ceragon Networks Ltd. shall not be liable for errors contained herein or for incidental or consequential damage in connection with the furnishing, performance, or use of this document or equipment supplied with it.

Open Source Statement

The Product may use open source software, among them O/S software released under the GPL or GPL alike license ("GPL License"). Inasmuch as such software is being used, it is released under the GPL License, accordingly. Some software might have changed. The complete list of the software being used in this product including their respective license and the aforementioned public available changes is accessible on http://www.gnu.org/licenses/.

Information to User

Any changes or modifications of equipment not expressly approved by the manufacturer could void the user’s authority to operate the equipment and the warranty for such equipment.

Page 3: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 3 of 63

Revision History

Rev Date Author Description Approved by Date

A November

22, 2011

Baruch Gitlin Initial release. Rami Lerner/Maxim

Feldman

November 22,

2011

B January 1,

2012

Baruch Gitlin Added 2+0 and OMT installation

instructions.

Rami Lerner/Maxim

Feldman

January 1,

2012

C March 14,

2012

Baruch Gitlin Update grounding procedures,

add section on surge protection,

revise marketing model and P/N

data, and rearrange sections.

Rami Lerner March 14,

2012

D May 3, 2012 Baruch Gitlin Added 2+0 configurations. Rami Lerner/Maxim

Feldman

May 3, 2012

E June 3, 2012 Baruch Gitlin Add 50m single mode cable

option.

Rami Lerner June 3, 2012

F June 19,

2012

Baruch Gitlin Revise marketing model for DC

cable drum for installation beyond

75m.

Rami Lerner June 19, 2012

G June 26,

2012

Baruch Gitlin Add list of test kits and updated

SFP options table.

Rami Lerner June 26, 2012

H October 28,

2012

Baruch Gitlin Added Appendix C: Connector

Pin-Outs and revised Appendix A:

Mediation Device Losses,

Rami Lerner October 28,

2012

Page 4: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 4 of 63

Table of Contents

1. FibeAir IP-10C Overview .................................................................................. 9

2. General Installation Procedures .................................................................... 10

2.1 Required Tools for Installation ..................................................................................... 10

2.2 Transportation .............................................................................................................. 10

2.3 Packing Inspection ....................................................................................................... 11

2.4 Location of the IP-10C ................................................................................................. 11

2.5 Installation Components............................................................................................... 12

2.6 Available Adapters and Installation Kits ....................................................................... 13

2.7 Antenna Connection ..................................................................................................... 15

2.8 Adjusting for Horizontal and Vertical Polarization ........................................................ 16

2.9 Connecting Flexible Waveguides to the IP-10C .......................................................... 17 2.9.1 Connecting the Waveguide in 6-13 GHz Bands .......................................................... 18 2.9.2 Connecting the Waveguide in 15-42 GHz Bands ........................................................ 18

2.10 Cable Connections and Grounding Procedure ............................................................ 20 2.10.1 Available Cable Options ............................................................................................... 20 2.10.2 SFP Options ................................................................................................................. 20 2.10.3 Accessory Kits .............................................................................................................. 20 2.10.4 Cap and Gland Installation ........................................................................................... 21 2.10.5 Cable Installation – General ......................................................................................... 22 2.10.6 Preparing and Connecting a Cat5E Cable ................................................................... 24 2.10.7 Connecting SFP Cables ............................................................................................... 27 2.10.8 Connecting Bundled Cat5 Cable and Power Cable ..................................................... 29 2.10.9 Connecting the Power Cable ....................................................................................... 30

2.11 Securing the Cables ..................................................................................................... 32

2.12 Grounding the Cables to the Antenna Tower Every 50m ............................................ 32

2.13 Grounding the IP-10C .................................................................................................. 33

2.14 Surge Protection .......................................................................................................... 34

3. IP-10C Configurations .................................................................................... 35

3.1 1+0 Direct Mount Installation ....................................................................................... 35

3.2 1+0 Remote Mount Installation .................................................................................... 36

3.3 1+1 HSB Direct Mount Installation ............................................................................... 39

3.4 1+1 HSB Remote Mount Installation ............................................................................ 42

3.5 2+0 Single Polarization (SP) Direct Mount Installation – Symmetrical Coupler .......... 44

3.6 2+0 Single Polarization (SP) Remote Mount Installation – Symmetrical Coupler ....... 48

3.7 2+0 Dual Polarization (DP) – Direct Mount Installation................................................ 50

3.8 2+0 Dual Polarization (DP) – Remote Installation ....................................................... 53

Page 5: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 5 of 63

4. Remote Mount Installation with an Imperial Waveguide .............................. 56

4.1 Remote Mount Installation with an Imperial Waveguide – 6-11 GHz .......................... 57

4.2 Remote Mount Installation with an Imperial Waveguide – 13-15 GHz ........................ 58

4.3 Remote Mount Installation with an Imperial Waveguide – 18-42 GHz ........................ 59

5. Appendix A: Mediation Device Losses ......................................................... 60

6. Appendix B: Test Kit Part Numbers .............................................................. 61

7. Appendix C: Connector Pin-Outs .................................................................. 62

7.1 Management Connector Pin-Out ................................................................................. 62

7.2 Power Connector Pin-Out ............................................................................................ 62

7.3 Ethernet 10/100/1000 Connector Pin-Out.................................................................... 63

7.4 Craft Terminal Connector Pin-Out ............................................................................... 63

Page 6: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 6 of 63

Safety Precautions & Declared Material

General Equipment Precautions

Use of controls, adjustments, or performing procedures other than those specified herein, may result in hazardous radiation exposure.

Machine noise information order - 3. GPSGV, the highest sound pressure level amounts to 70 dB (A) or less, in accordance with ISO EN 7779.

Static electricity may cause body harm, as well as harm to electronic components inside the device.

Anyone responsible for the installation or maintenance of the IP-10C must use an ESD Wrist Strap.

ESD protection measures must be observed when touching the RFU.

To prevent damage, before touching components inside the device, all electrostatic must be discharged from both personnel and tools.

In Norway and Sweden:

Equipment connected to the protective earthing of the building installation through the mains connection or through other equipment with a connection to protective earthing – and to a cable distribution system using coaxial cable, may in some circumstances create a fire hazard. Connection to a cable distribution system has therefore to be provided through a device providing electrical isolation below a certain frequency range (galvanic isolator, see EN 60728-11).

Utstyr som er koplet til beskyttelsesjord via nettplugg og/eller via annet jordtilkoplet utstyr – og er tilkoplet et kabel-TV nett, kan forårsake brannfare. For å unngå dette skal det ved tilkopling av utstyret til kabel-TV nettet installeres en galvanisk isolator mellom utstyret og kabel- TV nettet.” Translation to Swedish: ”Utrustning som är kopplad till skyddsjord via jordat vägguttag och/eller via annan utrustning och samtidigt är kopplad till kabel-TV nät kan i vissa fall medfőra risk főr brand. Főr att undvika detta skall vid anslutning av utrustningen till kabel-TV nät galvanisk isolator finnas mellan utrustningen och kabel-TV nätet.

!!

!!

!!

Page 7: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 7 of 63

Précautions générales relatives à l'équipement

L’utilisation de commandes ou de réglages ou l'exécution de procédures autres que celles spécifiées dans les présentes peut engendrer une exposition dangereuse aux rayonnements.

Bruit de machine d’ordre - 3. GPSGV, le plus haut niveau de pression sonore s'élève à 70 dB (A) au maximum, dans le respect de la norme ISO EN 7779.

Allgemeine Vorsichtsmaßnahmen für die Anlage

Wenn andere Steuerelemente verwendet, Einstellungen vorgenommen oder Verfahren durchgeführt werden als die hier angegebenen, kann dies gefährliche Strahlung verursachen.

Maschinenlärminformations-Verordnung - 3. GPSGV, der höchste Schalldruckpegel beträgt 70 dB(A) oder weniger gemäß EN ISO 7779.

!!

!!

!!

!!

Page 8: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 8 of 63

About This Guide

This guide describes the IP-10C installation procedures and provides additional

information concerning system parts and installation procedures.

What You Should Know

The IP-10C is an all outdoor module, which is based on the FibeAir IP-10Q and

RFU-C systems. The IP-10C is part of Ceragon’s outdoor system, using the same

waveguide and accessories.

Target Audience

This guide contains technical information about IP-10C installation, and is

intended for use by qualified Ceragon technical personnel at all levels.

Related Documents

FibeAir IP-10C Product Description - DOC-00029987

FibeAir IP-10C User Guide – DOC-00035560

FibeAir IP-10C MIB Reference – DOC-00033230

FibeAir IP-10 License Management System - DOC-00019183

FibeAir CeraBuild Commission Reports Guide, DOC-00028133

Page 9: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 9 of 63

1. FibeAir IP-10C Overview

FibeAir IP-10C is a state-of-the-art all-outdoor unit which is fully software configurable and supports a broad range of capacities and interfaces.

IP-10C – Front View IP-10C – Rear View

IP-10C provides a powerful, reliable, and comprehensive solution for a variety of wireless network scenarios and requirements.

Page 10: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 10 of 63

2. General Installation Procedures

This section provides instructions applicable for every IP-10C configuration.

Note: For all installation types, do not remove the transparent pressure window (mylar) from the antenna interface.

2.1 Required Tools for Installation

The following tools are required for an IP-10C installation:

Ball head socket key wrench, metric set

Phillips screwdriver #1,#2

Slot screwdriver 0.5x3x100

Slot screwdriver 1.6x10x200

Locking Pliers with plastic teeth

Wrench 24mm

2.2 Transportation

The equipment should be prepared for public transportation. The cargo must be kept dry during transportation, in accordance with ETS 300 019-1-2, Class 2.3.

It is recommended that the equipment be transported to the installation site in its original packing case.

If intermediate storing is required, the packed equipment must be stored in a dry and cool environment, and out of direct sunlight, in accordance with ETS 300 019-1-1, Class 1.2.

Page 11: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 11 of 63

2.3 Packing Inspection

Check that the package is not damaged.

Check the packing lists and verify that the correct equipment part numbers and quantities are found in the package that arrived.

Each IP-10C radio kit includes the following items:

IP-10C unit

2 Glands

5 Caps

Adapting bar kit

2 DC power connectors

2.4 Location of the IP-10C

Restricted Access Area: The IP-10C is intended for installation in a Restricted Access Area.

Distance: The IP-10C shall be installed within 140 feet (42.67 meters) from the building. Otherwise, Ethernet and other SELV connections will turn to TNV.

The IP-10C shall be installed in accordance with the national code and requirements of the country in which the IP-10C is being installed.

!!

Page 12: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 12 of 63

2.5 Installation Components

The following figures show the main components used in the IP-10C installation procedures.

IP-10C Adapting Bar

V/H Twist Coupler Holder with Coupler/OMT

Remote Pole Mount Kit

Page 13: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 13 of 63

2.6 Available Adapters and Installation Kits

Description 6GHz 7-8GHz 10-11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28-31GHz 32GHz 38GHz 42GHz

RFU-C COUPLER KIT RFU-C6-CPLR-Kit

RFU-C7_8-CPLR-Kit

RFU-C10_11-CPLR-Kit

RFU-C13-CPLR-Kit

RFU-C15-CPLR-Kit*0

RFU-C18-CPLR-Kit*0

RFU-C23-CPLR-Kit

RFU-C26-CPLR-Kit

RFU-C28-CPLR-Kit

RFU-C32-CPLR-Kit

RFU-C38-CPLR-Kit

RFU-C42-CPLR_Kit

RFU-C SYMMETRICAL COUPLERS KIT

NA RFU-C7_8-Sym-cplr-kit

NA RFU-C13-Sym-cplr-kit

RFU-C15-Sym-cplr-kit

RFU-C18-Sym-cplr-kit

RFU-C23-Sym-cplr-kit

NA

RFU-C TWIST KIT RFU-C6-TWST-Kit

RFU-C7_8-TWST-Kit

RFU-C10_11-TWST-Kit

RFU-C13-TWST-Kit

RFU-C15-TWST-Kit

RFU-C18-TWST-Kit

RFU-C23_26-TWST-Kit RFU-C28_32-TWST-Kit RFU-C38-TWST-Kit

RFU-C42-TWST-Kit

RFU-C OMT KIT RFU-C6-OMT-DM-Kit

RFU-C7_8-OMT-DM-Kit

RFU-C10_11-OMT-DM-Kit

RFU-C13-OMT-DM-Kit

RFU-C15-OMT-DM-Kit

RFU-C18-OMT-DM-Kit

RFU-C23-OMT-DM-Kit

RFU-C26-OMT-DM-Kit

RFU-C28-OMT-DM-Kit

RFU-C32-OMT-DM-Kit

RFU-C38-OMT-DM-Kit

RFU-C42-OMT-DM-Kit

RFU-C ADAPTORS OMT KIT

RFU-C6-OMT-ADAPT

RFU-C7_8-OMT-ADAPT

RFU-C10_11-OMT-ADAPT

NA

RFU-C SHORT OMT KIT

RFU-C-OMT-SHORT-PLATE

Remote Mount 6GHz 7-8GHz 10-11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28-31GHz 32GHz 38GHz 42GHz

RFU-C REMOTE MOUNT KIT

RFU-C-PoleMount

RFU-C ADAPTOR REMOTE MOUNT KIT

RFU-C6-RM_ADAPT

RFU-C7_8-RM_ADAPT

RFU-C10_11-RM_ADAPT

RFU-C13-RM_ADAPT

RFU-C WG Kit Flx-WG-4FT-6 Flx-WG-4FT-7_8

Flx-WG-4FT-10_11

Flx-WG-3FT-13

Flx-WG-3FT-15

Flx-WG-3FT-18-26 Flx-WG-3FT-28-38 Flx-WG-3FT-42

Page 14: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 14 of 63

Antenna Circ. Adapters for

OMT 6GHz 7-8GHz 10-11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28GHz 32GHz 38GHz 42GHz

Andrew RFU-C6-OMT-INT-A

RFU-C7_8-OMT-INT-A

RFU-C10_11-OMT-INT-A

RFU-C13-OMT-INT-A

RFU-C15-OMT-INT-A

RFU-C18-OMT-INT-A

RFU-C23-OMT-INT-A

RFU-C26-OMT-INT-A

RFU-C28-OMT-INT-A

RFU-C32-OMT-INT-A

RFU-C38-OMT-INT-A

RFU-C42-OMT-INT-A

RFS 1FT NA NA NA RFU-C13-OMT-INT-1FT-R

RFU-C15-OMT-INT-1FT-R

RFU-C18-OMT-INT-1FT-R

RFU-C23-OMT-INT-1FT-R

RFU-C26-OMT-INT-1FT-R

RFU-C28-OMT-INT-1FT-R

RFU-C32-OMT-INT-1FT-R

RFU-C38-OMT-INT-1FT-R

NA

RFS 2-6FT RFU-C6-OMT-INT-2_6FT-R

RFU-C7_8-OMT-INT-2_6FT-R

RFU-C10_11-OMT-INT-2_6FT-R

RFU-C13-OMT-INT-2_6FT-R

RFU-C15-OMT-INT-2_6FT-R

RFU-C18-OMT-INT-2_6FT-R

RFU-C23-OMT-INT-2_6FT-R

RFU-C26-OMT-INT-2_6FT-R

RFU-C28-OMT-INT-2_6FT-R

RFU-C32-OMT-INT-2_6FT-R

RFU-C38-OMT-INT-2_6FT-R

NA

GD RFU-C6-OMT-INT-GD

RFU-C7_8-OMT-INT-GD

RFU-C10_11-OMT-INT-GD

RFU-C13-OMT-INT-GD

RFU-C15-OMT-INT-GD

RFU-C18-OMT-INT-GD

RFU-C23-OMT-INT-GD

RFU-C26-OMT-INT-GD

RFU-C28-OMT-INT-GD

RFU-C32-OMT-INT-GD

RFU-C38-OMT-INT-GD

NA

Radio Waves

RFU-C6L-OMT-INT-RW / RFU-C6H-OMT-INT-RW

RFU-C7_8-OMT-INT-RW

RFU-C10_11-OMT-INT-RW

RFU-C13-OMT-INT-RW

RFU-C15-OMT-INT-RW

RFU-C18-OMT-INT-RW

RFU-C23-OMT-INT-RW

RFU-C26-OMT-INT-RW

RFU-C28-OMT-INT-RW

NA RFU-C38-OMT-INT-RW

NA

Shenglu RFU-C7_8-OMT-INT-SH

RFU-C10_11-OMT-INT-SH

RFU-C13-OMT-INT-SH

RFU-C15-OMT-INT-SH

RFU-C18-OMT-INT-SH

RFU-C23-OMT-INT-SH

RFU-C26-OMT-INT-SH

Xian Putian RFU-C6-OMT-INT-X

RFU-C7_8-OMT-INT-X

RFU-C10_11-OMT-INT-X

RFU-C13-OMT-INT-X

RFU-C15-OMT-INT-X

RFU-C18-OMT-INT-X

RFU-C23-OMT-INT-X

RFU-C26-OMT-INT-X

RFU-C28-OMT-INT-X

RFU-C32-OMT-INT-X

RFU-C38-OMT-INT-X

NA

Imperial to mm Transitions 6GHz 7-8GHz 10-11GHz 13GHz 15GHz 18GHz 23GHz 26GHz 28-31GHz 32GHz 38GHz 42GHz

RFU-C ADAPTOR KIT TO IMPERIAL ANT.

ADPT_RFU-C6-RM_Imp

ADPT_RFU-C7_8-RM_Imp

ADPT_RFU-C10_11-RM_Imp

ADPT_RFU-C13-RM_Imp

ADPT_RFU-C15-RM_Imp

ADPT_RFU-C18_26-RM_Imp ADPT_RFU-C28_38-RM_Imp NA

RFU-C ADAPTOR KIT TO IMP WG ADPT_RFU-C6-RM_mill

ADPT_RFU-C7_8-RM_mill

ADPT_RFU-C10_11-RM_mill

ADPT_RFU-C13-RM_mill

ADPT_RFU-C15-RM_mill

ADPT_RFU-C18_26-RM_mill ADPT_RFU-C28_38-RM_mill NA

Page 15: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 15 of 63

2.7 Antenna Connection

IP-10C uses Andrew, General Dynamics, RFS, Shenglu and Xian Putian antennas.

IP-10C can be mounted directly for all frequencies (6-42 GHz) using the following antenna types (for integrated antennas, specific antennas PNs are required):

Andrew: VHLP series

RFS: SB/SU series

Shenglu: SLC series

Xian Putian: WTC/WTG series

General Dynamics: HPS series

For remote mount installations, the following flexible waveguide flanges should be used (millimetric). The same antenna type (integrated) as indicated above can be used (recommended).

Other antenna types using the flanges listed in the table below may be used.

If a different antenna type (CPR flange) is used, a flange adaptor is required. Please contact your Ceragon representative for details.

Note: Conductive grease must be applied to the screws that connect the IP-10C to the antenna interface.

Frequency Circ. WG Diameter

Rect. WG Flange Des. Radio Side (Remote) Flange Des.

Flex WG Side A Flange Des.

Flex WG Side B Flange Des.

Antenna (Remote) Flange Des.

Band Range (GHz)

6(L/U) GHz 5.8-7.1 31.8mm WR137 UDR70 PDR70 PDR70 UDR70

7/8 GHz 7.1-8.5 26mm WR112 UBR84 PBR84 PBR84 UBR84

10/11 GHz 10.0-11.7 18mm WR90 UBR100 PBR100 PBR100 UBR100

13 GHz 12.7-13.3 15mm WR75 UBR120 PBR120 PBR120 UBR120

15 GHz 14.5-15.4 13.5mm WR62 UBR140 PBR140 PBR140 UBR140

18 GHz 17.7-19.7 10.5mm WR42 UBR220 PBR220 PBR220 UBR220

23 GHz 21.2-23.6 9mm

26 GHz 24.5-26.6 8mm

28-31GHz 27.3-29.5 7mm WR28 UBR320 PBR320 PBR320 UBR320

32GHz 31.8-33.4 6.5mm

38GHz 37.0-40.0 5.5mm

42GHz 40.5-43.5 4.775mm WR22 UG383/U UG383/U UG383/U UG383/U

Page 16: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 16 of 63

2.8 Adjusting for Horizontal and Vertical Polarization

Polarization changes in the IP-10C are made by adjusting the iris on the antenna port.

Attach the iris using two M3 screws, according to the antenna polarization:

For horizontal polarization, locate the holes above and below the letter “H” on the pins and fasten the two screws.

Page 17: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 17 of 63

For vertical polarization, locate the holes above and below the letter “V” on the pins and fasten the two screws.

Note: For 6 GHz, separate irises are used for vertical and horizontal polarization. The vertical iris comes assembled with the IP-10C. The horizontal iris (MA-1840-X, IP-10C Twist 6Ghz Horizontal) is included in the IP-10C package.

2.9 Connecting Flexible Waveguides to the IP-10C

For an IP-10C operating in bands of 6-13 GHz, a remote mount adaptor must be used to connect a flexible waveguide.

For an IP-10C operating in bands of 15-42 GHz, you must remove the iris before connecting a flexible waveguide to the antenna port.

The following table provides the marketing models for the remote mount waveguide adaptor kits required, per frequency.

Freq (WG standard) 6HGz (UBR70) 7-8GHz (UBR84) 10-11GHz (UBR100) 13GHz (UBR120)

Remote Mount WG

adaptor kit

RFU-C6-RM_ADAPT RFU-C7_8-RM_ADAPT RFU-C10_11-RM_ADAPT RFU-C13-RM_ADAPT

Remote Mount Kit RFU-C-PoleMount

Page 18: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 18 of 63

2.9.1 Connecting the Waveguide in 6-13 GHz Bands

1 Mount the remote adaptor and O-Ring to the pole mount using the four M5 flat screws supplied in the Remote Mount Adaptor kit, and tighten the screws.

2 Connect the flexible waveguide to the remote mount adaptor. Use screws (supplied with the waveguide kit) to fasten the waveguide.

2.9.2 Connecting the Waveguide in 15-42 GHz Bands

1 Remove the iris from the IP-10C (no adaptor is required for the 15-42 GHz bands).

2 Connect the waveguide to the antenna adaptor interface (the interface exposed by removing the iris). Use four screws (supplied with the waveguide kit) to fasten the waveguide end to the antenna adapter interface.

Page 19: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 19 of 63

Note: It is normal for the flexible waveguide to reach the IP-10C at an angle of approximately 45°, as shown in the figure below.

Page 20: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 20 of 63

2.10 Cable Connections and Grounding Procedure

2.10.1 Available Cable Options

MARKETING P/N DESCRIPTION

IP-10C_Eth_cbl_50m IP10-C CAT5E CABLE

IP-10C_Eth_cbl_75m IP10-C CAT5E CABLE

IP-10C_Eth_cbl_1m IP-10C external Eth cable 1m

CAT5-4P-CABLE CAT-5E 4X2X24AWG,DOUBLE JACKET UV RESISTANCE,100m cable

IP-10C_Bundled_cbl_50m IP10-C BUNDLED CABLE

IP-10C_Bundled_cbl_75m IP10-C BUNDLED CABLE

DC_CAT5E_Bundled_drum Bundled cable drum, DC 2x18AWG, CAT5E 305M

Outdoor_DC_cbl_2x18AWG_drum DC cable drum for installation up to 75m

Outdoor_DC_cbl_2x12AWG_drum DC cable drum for installation beyond 75m

OP-MM-CBL-LC-LC-DPLX 100M OUT Optical cable Multi Mode LC-LC 100m OUTDOOR

OP-MM-CBL-LC-LC-DPLX 75M OUT Optical cable Multi Mode LC-LC 75m OUTDOOR

OP-MM-CBL-LC-LC-DPLX 50M OUT Optical cable Multi Mode LC-LC 50m OUTDOOR

OP-SM-CBL-LC-LC-DPLX 100M OUT Optical cable Single Mode LC-LC 100m OUTDOOR

OP-SM-CBL-LC-LC-DPLX 75M OUT Optical cable Single Mode LC-LC 75m OUTDOOR

OP-SM-CBL-LC-LC-DPLX 50M OUT Optical cable Single Mode LC-LC 50m OUTDOOR

2.10.2 SFP Options

SFP-GE-SX-EXT-TEMP SFP optical interface 1000Base-SX,EXT-TE

SFP-GE-LX-EXT-TEMP SFP OPTICAL 1000Base-LX,EXT TEMP

2.10.3 Accessory Kits

GBE_connector_kit 10 GBE connectors and protective rubber boots

IP-10C_Glands_x5_kit 2. 5 IP-10C glands kit

Page 21: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 21 of 63

2.10.4 Cap and Gland Installation

1 Mount the gland/cap with the O-Ring to the desired location and tighen it until there is full contact (see figure below) between the gland/gland cap and the cover.

Use the large (1.6x10x200) slot screwdriver to tighten the cap.

Use the locking pliers or 24mm wrench to tighten the gland.

Page 22: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 22 of 63

2.10.5 Cable Installation – General

1 Open the bottom cover of the IP-10C.

Note: Do not remove the gasket.

Do not remove or cut the wire securing the cover to the IP-10C.

2 Connect the cables, as described in detail in the following sections:

Preparing and Connecting a Cat5E Cable

Connecting the Power Cable

Connecting SFP Cable

Connecting Bundled Cat5 Cable and Power Cable

3 Close the bottom cover using five M4 captive screws

Page 23: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 23 of 63

4 Thread the screws without fastening. After all five screws are threaded in the required location, tighten the screws diagonally with 2.6Nm torque.

5 Tighten the gland cap using 10 Nm torque

Page 24: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 24 of 63

2.10.6 Preparing and Connecting a Cat5E Cable

6 Take the Cat5E cable and strip off about 70mm of the outer insulation jacket.

7 Strip off about 15mm of the inner insulation jacket.

8 Release the gland cap slightly.

9 Insert the Cat5 cable into the Cable gland.

10 Insert the Cat5 plug boot into the cable with its face up.

11 Roll back the foil shield insulation and wrap the drain wire around the foil. Do not remove any insulation from the conductors.

Page 25: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 25 of 63

12 Align the colored wires.

Note: Cord colors should be matched to the same pins on both ends of the cable.

13 Trim all the wires to the same length. About 12mm on the left should be exposed from the inner sheath.

14 Insert the wires into the RJ45 plug. Make sure each wire is fully inserted into the front of the RJ45 plug and in the correct order. The sheath of the Ethernet cable should extend into the plug by about ½ inches and will be held in place by the crimp.

15 The cable jacket with shield must extend into the connector about 5mm for strain relief and shielding connection.

16 Crimp the RJ45 plug with the crimper tool.

17 Verify that the wires ended up the right order and that the wires extend to the front of the RJ45 plug and make good contact with the metal contacts in the RJ45 plug.

18 Push back the Cat5 plug cover on the connector plug.

19 Disassemble the relevant cap.

Page 26: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 26 of 63

20 Insert the cable into the relevant hole in the small cover and tighten until there is full contact between the gland and the cover.

21 Connect the assembled connector into the IP-10C plug connector.

22 Once all the cables have been installed, close the small cover using five captive screws and tighten the gland cap with 10 Nm torque.

Page 27: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 27 of 63

2.10.7 Connecting SFP Cables

1 Use a pre-assembled cable.

2 Split the connector into two separate blue units (one for each wire).

3 Release the gland cap slightly.

4 Insert wires with connector one by one into the cable gland.

5 Disassemble the middle cap. 6 Insert the cable wires one by one into the middle hole.

Page 28: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 28 of 63

7 Insert the gland into the middle hole in the small cover and tighten unti there is full contact.

8 Connect the connector into the IP-10C plug connector.

9 Insert the gland into the small cover and tighten until there is full contact between the gland and the cover.

10 Once all the cables have been installed, close the small cover using five captive screws and tighten the gland cap with 10 Nm torque.

Page 29: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 29 of 63

2.10.8 Connecting Bundled Cat5 Cable and Power Cable

1 Assemble the gland, and tighten until there is full contact.

2 Perform steps 7 through 8 in section ‎2.10.9, Connecting the Power Cable. 3 Connect the assembled Cat5 connector into the IP-10C plug connector. 4 Connect the power cable to the power connector in the IP-10C, as

described in steps 9 through 10 in section ‎2.10.9, Connecting the Power Cable.

5 Connect the grounding shield to the body with serrated washers, plain washer and M6 Nut.

6 Once all the cables have been installed, close the small cover using five captive screws and tighten the gland cap with 10 Nm torque.

Page 30: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 30 of 63

2.10.9 Connecting the Power Cable

1 Strip off 45mm from the cable jacket. 2 Expose 10mm at the edge of each of the two wires.

3 Replace the left cap with a gland, and tighten it. Tighten until there is full contact.

4 Release the gland cap slightly.

5 Insert the power cable into the gland assembled in the small cover.

6 Insert the power cable wires into the power connector. 7 Match “+” and “–“to the red and black cord colors according to the power

supply connection cord colors (for + and – locations, refer to the figure below).

Page 31: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 31 of 63

8 Tighten the two top screws.

9 Plug in the power cable with connector into the IP-10C power connector.

10 Tighten the two front screws.

11 Once all the cables have been installed, close the small cover using five captive screws and tighten the gland cap with 10 Nm torque.

Page 32: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 32 of 63

2.11 Securing the Cables

All cables should be secured on site using a T-Rups kit, P/N Outdoor Ties (SI-0027-0), every meter. When using this kit, take special care to apply the proper amount of force in order to avoid damaging the cable being secured. This is especially important for optical (SFP) cables.

The following clamps are available for optical (fiber) cables:

Part Number Marketing Model Item Description

SI-0954-0 Fiber_clamp_2cbl_6.5-

7.5mm DUAL FEADER CLAMP FOR 6.5-7.5mm CABLE 2

WAY.

The following clamps are available for bundled Cat5 cables:

Part Number Marketing Model Item Description

SI-0766-0 RG8 8 feeder clamp DUAL FEADER CLAMP FOR RG-8/U CABLE 8 WAY.

SI-0765-0 RG8 6 feeder clamp DUAL FEADER CLAMP FOR RG-8/U CABLE 6 WAY.

SI-0764-0 RG8 4 feeder clamp DUAL FEADER CLAMP FOR RG-8/U CABLE 4 WAY.

SI-0763-0 RG8 2 feeder clamp DUAL FEADER CLAMP FOR RG-8/U CABLE 2 WAY.

2.12 Grounding the Cables to the Antenna Tower Every 50m

Cables must be grounded as follows:

For optical (SFP) cable (see Connecting SFP Cables on page 27), no grounding is required.

For combined cables (see Connecting Bundled Cat5 Cable and Power Cable on page 29), the cable should be grounded to the antenna tower every 50m, using an SI-0391-0 grounding kit, IF RG-8 GRD KIT.

Page 33: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 33 of 63

2.13 Grounding the IP-10C

1 On the front side of each IP-10C, loosen the nut, plain washer, and serrated washer.

2 Place the cable lug (supplied with the IP-10C housing kit) on the screw. 3 Secure the cable lug.

IP-10C Grounding Cable

The unit’s earthing screw terminal shall be permanently connected to protective earth in a building installation in accordance with applicable national code and regulations by a service person.

A 2-Pole circuit breaker, a branch circuit protector, suitably certified in accordance with applicable national code and regulations, rated maximum 20A, shall be installed for full power disconnection in a building installation.

Any outdoor antenna cable shield shall be permanently connected to protective earth in a building installation.

When selecting a power source, the following must be considered:

DC power can be from -40 VDC to -60 VDC.

Recommended: Availability of a UPS (Uninterrupted Power Source), battery backup, and emergency power generator.

Whether or not the power source provides constant power (i.e., power is secured on weekends or is shut off frequently and consistently).

The power supply must have grounding points on the AC and DC sides.

Caution!

The user power supply GND must be connected to the positive pole in the IP-10C

power supply. Any other connection may cause damage to the system!

Important: For the warranty to be honored, you must install the IP-10C in accordance with the instructions above.

!!

Page 34: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 34 of 63

2.14 Surge Protection

IP-10C includes built-in surge protection for its Ethernet and power interfaces. IP-10C’s surge protection mechanism complies with surge immunity standard IEC 61000-4-5, level 4, provided the Ethernet cables were prepared according to the instructions in Preparing and Connecting a Cat5E Cable on page 24.

Page 35: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 35 of 63

3. IP-10C Configurations

3.1 1+0 Direct Mount Installation

The following components are necessary for a 1+0 Direct Mount installation:

Item Description Quantity Remarks

1 IP-10C RADIO 1

In a direct mount installation, the IP-10C is directly mounted on the antenna, without the use of flexible waveguides.

1 Adjust the iris according to the required polarization. 2 Mount the adapting bar using two M8 flat screws on the antenna.

3 Mount the IP-10C on the antenna using the four M8 captive screws and washers supplied, assembled, in the IP-10C, and thread the screws without fastening. After all four screws are threaded to the required location, tighten the screws starting from the bottom screws.

4 Connect the cables as described in Cable Connections and Grounding Procedure on page 20.

Page 36: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 36 of 63

3.2 1+0 Remote Mount Installation

The following components are necessary for a 1+0 Remote Mount installation:

Item Description Quantity Remarks

1 IP-10C RADIO 1

2 RFU-C REMOTE MOUNT KIT 1 For Remote Mount

3 REMOTE MOUNT ADAPTOR 1 For Remote Mount 6-13 GHz

For 6-13 GHz:

1 Mount the remote adaptor and O-Ring to the pole mount using the four M5 flat screws supplied in the Remote Mount Adaptor kit, and tighten the screws.

2 Mount the adapting bar using two M8 flat screws. 3 Mount the IP-10C on the antenna using the four M8 captive screws and

washers supplied, assembled, in the IP-10C, and thread the screws without fastening. After all four screws are threaded to the required location, tighten the screws starting from the bottom screws.

4 Place the O-Ring into the flange groove on both ends of the flexible waveguide.

5 Connect the flexible waveguide to the remote mount adaptor and tighten the screws and washers.

6 Mount the flexible waveguide on the antenna, and tighten the screws and washers.

7 Connect the cables as described in Cable Connections and Grounding Procedure on page 20.

Page 37: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 37 of 63

For 15-42 GHz:

1 Remove the IRIS from the IP-10C.

2 Mount the adapting bar using two M8 flat screws. 3 Mount the IP-10C on the bracket using the four M8 captive screws and

washers supplied, assembled, in the IP-10C, and thread the screws without fastening. After all four screws are threaded to the required location, tighten the screws starting from the bottom screws.

4 Place the O-Ring into the flange groove on both ends of the flexible waveguide.

5 Connect the flexible waveguide to the IP-10C antenna adaptor interface (the interface exposed by removing the iris).

Note: It is normal for the flexible waveguide to reach the IP-10C at an angle of approximately 45°, as shown in the figure below.

Page 38: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 38 of 63

6 Use four screws and washers (supplied with the waveguide kit) to fasten the waveguide end to the antenna adapter interface.

7 Mount the flexible waveguide on the antenna, and tighten the screws and washers.

8 Connect the cables as described in Cable Connections and Grounding Procedure on page 20.

Page 39: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 39 of 63

3.3 1+1 HSB Direct Mount Installation

The following components are necessary for a 1+1 HSB direct mount installation:

Item Description Quantity Remarks

I IP-10C RADIO 2

2 RFU-C COUPLER KIT 1

3 RFU-C TWIST 1

In 1+1 direct mount configuration, the IP-10-C is attached to a coupler.

Important! Do not remove the transparent pressure window located on the coupler ports!

To install an IP-10C in a 1+1 HSB direct mount configuration:

Notes: For 15 and 18 GHz frequencies, two O-Rings are supplied in the Twist kit and should be mounted in the twist grooves.

For the 6 GHz frequency, a gasket is used instead of an O-Ring. The gasket should be mounted between the twist and the RFU-C Coupler kit.

1 Mount the twist to the coupler using the O-Ring and four screws supplied in the Twist kit, and tighten the screws.

Important: Make sure the polarization mounting direction of the twist to the coupler is according to the antenna polarization.

Page 40: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 40 of 63

2 Mount the coupler radio on the antenna using the four M8 screws and washers supplied with the RFU-C Coupler kit, and tighten the screws.

3 Mount the two O-Rings supplied with the RFU-C Coupler kit, as shown in the following figures.

4 Mount the adapting bar on the coupler holder using two M8 flat screws. 5 Mount both IP-10C units on the coupler holder, and tighten them using the

four M8 captive screws and washers, supplied with the IP-10C. Thread the screws without fastening. After all four screws are threaded in the correct location, tighten the screws starting from the bottom screws.

H V

Page 41: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 41 of 63

Important! Pay attention to the polarization mounting direction.

Page 42: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 42 of 63

3.4 1+1 HSB Remote Mount Installation

The following components are necessary for a 1+1 HSB remote mount installation:

Item Description Quantity Remarks

I IP-10C RADIO 2

2 RFU-C COUPLER KIT 1

3 RFU-C REMOTE MOUNT ADAPTOR KIT 1 For 6-13 GHz

In 1+1 remote mount configuration, the IP-10C is attached to a coupler.

Important! Do not remove the transparent pressure window located on the coupler ports!

To install an IP-10C in a 1+1 HSB remote mount configuration:

1 For 6-13 GHz installations only, mount the RFU-C remote adaptor and O-Ring to the pole mount using the four flat M5 screws supplied in the RFU-C Remote Mount Adaptor kit, and tighten the screws.

2 Mount the IP-10C coupler to the RFU-C pole mount bracket using the four M8 screws and washers supplied with the RFU-C Coupler kit, and tighten the screws.

Page 43: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 43 of 63

3 Mount the two O-Rings supplied with the RFU-C Coupler kit, as shown in the following figures.

4 Mount the adapting bar on the coupler holder using two M8 flat screws. 5 Mount both IP-10C units on the coupler holder, and tighten them using the

four M8 captive screws and washers supplied, with the IP-10C. Thread the screws without fastening. After all four screws are threaded in the correct location, tighten the screws starting from the bottom screws.

6 Place the O-Ring in the flexible waveguide flange groove. 7 Mount the flexible waveguide on the coupler, and tighten the screws and

washers. 8 Place the O-Ring in the other end of the flexible waveguide flange groove. 9 Mount the flexible waveguide on the antenna, and tighten the screws and

washers.

Page 44: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 44 of 63

3.5 2+0 Single Polarization (SP) Direct Mount Installation – Symmetrical Coupler

The following components are necessary for a 2+0 SP direct mount installation:

Item Description Quantity Remarks

I IP-10C RADIO 2

2 RFU-C SYMMETRICAL COUPLER KIT 1

3 RFU-C TWIST 1

In 2+0 direct mount configuration, the IP-10-C is attached to a symmetrical coupler.

Important! Do not remove the transparent pressure window located on the symmetrical coupler ports!

To install an IP-10C in a 2+0 SP direct mount configuration:

1 Remove the Extender from the Symmetrical Coupler by loosening and removing the four M4 screws and washers, as shown in following figure.

Page 45: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 45 of 63

2 Mount the twist to the Circulator/Symmetrical Coupler using the O-Ring and four screws supplied in the Twist Kit. Tighten the screws.

Note: For 15 and 18 GHz frequencies, two O-Rings are supplied in the Twist Kit and should be mounted in the twist grooves.

For the 6 GHz frequency, a gasket is used instead of an O-Ring. The gasket should be mounted between the twist and the RFU-C Circulator/Symmetrical Coupler Kit.

Important! Make sure the polarization mounting direction of the twist to the RFU-C circulator / symmetrical coupler is according to the antenna polarization.

Page 46: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 46 of 63

3 Mount the Circulator/Symmetrical Coupler on the antenna using the four M8 screws and washers supplied with the RFU-C Circulator/Symmetrical Coupler Kit, and tighten the screws.

4 Mount the two O-Rings supplied with the RFU-C Circulator/Symmetrical Coupler Kit.

5 Mount the adapting bar on the coupler holder using two M8 flat screws. 6 Mount both IP-10C units on the coupler holder, and tighten them using the

four M8 captive screws and washers, supplied with the IP-10C. Thread the screws without fastening. After all four screws are threaded in the correct location, tighten the screws starting from the bottom screws.

H V

Page 47: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 47 of 63

Important! Pay attention to the polarization mounting direction.

Page 48: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 48 of 63

3.6 2+0 Single Polarization (SP) Remote Mount Installation – Symmetrical Coupler

The following components are necessary for a 2+0 SP remote mount installation:

Item Description Quantity Remarks

I IP-10C RADIO 2

2 RFU-C SYMMETRICAL COUPLER KIT 1

3 RFU-C REMOTE MOUNT KIT 1

In 2+0 SP remote mount configuration, the IP-10C is attached to a symmetrical coupler.

Important! Do not remove the transparent pressure window located on the symmetrical coupler ports!

To install an IP-10C in a 2+0 SP remote mount configuration:

1 Mount the IP-10C coupler to the RFU-C pole mount bracket using the four M8 screws and washers supplied with the RFU-C Symmetrical Coupler kit, and tighten the screws.

Page 49: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 49 of 63

2 Mount the two O-Rings supplied with the RFU-C Symmetrical Coupler kit, as shown in the following figures.

3 Mount the adapting bar on the coupler holder using two M8 flat screws. 4 Mount both IP-10C units on the coupler holder, and tighten them using the

four M8 captive screws and washers supplied, with the IP-10C. Thread the screws without fastening. After all four screws are threaded in the correct location, tighten the screws starting from the bottom screws.

5 Place the O-Ring in the flexible waveguide flange groove. 6 Mount the flexible waveguide on the coupler, and tighten the screws and

washers. 7 Place the O-Ring in the other end of the flexible waveguide flange groove. 8 Mount the flexible waveguide on the antenna, and tighten the screws and

washers.

Page 50: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 50 of 63

3.7 2+0 Dual Polarization (DP) – Direct Mount Installation

ACDP

Note: This is not an XPIC configuration.

A 2+0 DP IP-10C configuration requires installation of an Orthogonal Mode Transducer (OMT).

Important! Do not remove the transparent pressure window located on the OMT ports !

The following components are necessary for a 2+0 DP installation:

Item Description Quantity Remarks

1 ANTENNA OMT ADAPTOR 1

2 RFU-C OMT 1

3 IP-10C 2

1. Prior to the installation, follow the antenna manufacturer’s instructions to switch to a circular adaptor (remove the existing rectangular adapter, swap the O-ring, and install the circular adaptor in its place).

Page 51: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 51 of 63

2. Mount the OMT kit on the antenna using four M8 screws and washers (supplied with the OMT kit). Do not tighten them yet, to allow rotation of the entire assembly.

3. Mount the two O-Rings (supplied with the OMT kit) on the OMT body. Pay attention to the mounting direction, as shown in the section view.

4. Connect the iris to the IP-10C using two M3 screws, according to the OMT port polarization

5. Mount the adapting bar on the OMT holder using two M8 flat screws.

Page 52: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 52 of 63

6. Mount both IP-10C units on the OMT holder, and tighten them using the four M8 captive screws and washers supplied, with the IP-10C. Thread the screws without fastening. After all four screws are threaded in the correct locations, tighten the screws starting from the bottom screws.

Important! Pay attention to the polarization mounting direction.

9 Tilt the entire assembly, to achieve maximum XPD (Cross Polar Differentiation).

10 Connect the cables and ground the IP-10C units, as described in Cable Connections and Grounding Procedure on page 20.

Page 53: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 53 of 63

3.8 2+0 Dual Polarization (DP) – Remote Installation

ACDP

When a remote configuration is required, the OMT is attached directly to the antenna and the IP-10C units are installed remotely, using a flexible waveguide. Before connecting WGs to the OMT, please connect mm to imperial adaptor to the OMT

Frequencies 13-42 GHz do not require adaptors

Frequencies 6-11 GHz require adaptors, as described in the instructions below.

Important! Do not remove the transparent pressure window located on the OMT ports!

The following components are necessary for a 2+0 DP remote installation:

Item Description Quantity Remarks

1 ANTENNA OMT ADAPTOR 1

2 RFU-C OMT 1

3 IP-10C 2

4 RFU-C OMT ADAPTOR KIT 1 Optional

5 RFU-C REMOTE MOUNT KIT 1

Freq. (WG standard) 6HGz (UDR70) 7-8GHz (UBR84) 10-11GHz (UBR100)

IPPON ADAPTORS OMT KIT RFU-C6-OMT-ADAPT RFU-C7_8-OMT-ADAPT RFU-C10_11-OMT-ADAPT

11 For 6Ghz (UDR70):

i Mount the O-Ring supplied with the OMT kit. ii Mount OMT Adaptor #1 on the OMT, and tighten using four M4 screws

and washers (supplied with the OMT adaptor kit). iii Mount OMT Adaptor #2 on OMT Adaptor #1, and tighten using four M4

screws and washers (supplied with the OMT adaptor kit).

Page 54: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 54 of 63

iv Mount the flexible waveguide as usual.

12 For 7-11 GHz (UBR84 and UBR100):

i Mount the O-Ring supplied with the OMT kit. ii Mount the OMT adaptor, with its installed sealing gasket, on the OMT,

and tighten using the four M4 screws and washers supplied with the OMT Adaptor kit.

iii Mount the flexible waveguide without its gasket (only for the OMT side).

Page 55: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 55 of 63

13 For 13 GHz (UBR120) to 42 GHz (UG383/U), connect the flexible waveguide and its gasket (supplied with the Flexible WG Kit) directly to the OMT port.

14 Connect the other end of the flexible waveguide to the IP-10C Radio port.

Page 56: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 56 of 63

4. Remote Mount Installation with an Imperial Waveguide

List of Items

Item Description Quantity Remarks

1 IP-10C RADIO 1

2 FLEXIBLE WG IMPERIAL KIT 1

3 RFU-C REMOTE MOUNT ADAPTOR KIT 1 Up to 15 GHz

4 RFU-C REMOTE POLE MOUNT KIT 1

Required Tools

Metric offset hexagon key wrench set

Imperial offset hexagon key wrench set

Page 57: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 57 of 63

4.1 Remote Mount Installation with an Imperial Waveguide – 6-11 GHz

1 Mount the RFU-C Adaptor supplied with the RFU-C Adaptor kit on the RFU-C Remote Pole Mount kit using the four flat screws supplied with the RFU-C Adaptor kit.

2 Mount the adapting bar using two M8 flat screws. 3 Mount the IP-10C unit on the Remote Pole Mount kit, and tighten it using

the four M8 captive screws and washers supplied, with the IP-10C. Thread the screws without fastening. After all four screws are threaded in the correct location, tighten the screws starting from the bottom screws.

4 Connect the Flexible Waveguide and Sealing Gasket supplied with the Flexible Waveguide Imperial kit to the RFU-C Adaptor. Tighten the screws supplied with the Flexible Waveguide Imperial kit.

Page 58: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 58 of 63

4.2 Remote Mount Installation with an Imperial Waveguide – 13-15 GHz

1 Mount the RFU-C Adaptor supplied with the RFU-C Remote Pole Mount kit using the four flat screws supplied with the RFU-C Adaptor kit.

2 Mount the adapting bar using two M8 flat screws. 3 Mount the IP-10C unit on the Remote Pole Mount kit, and tighten it using

the four M8 captive screws and washers supplied, with the IP-10C. Thread the screws without fastening. After all four screws are threaded in the correct location, tighten the screws starting from the bottom screws.

4 Connect the Flexible Waveguide and sealing O-Ring supplied with the Flexible Waveguide Imperial kit to the RFU-C Adaptor. Tighten the four screws supplied with the Flexible Waveguide Imperial kit.

Page 59: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 59 of 63

4.3 Remote Mount Installation with an Imperial Waveguide – 18-42 GHz

1 Mount the RFU-C Adaptor supplied with the RFU-C Remote Pole Mount kit using the four flat screws supplied with the RFU-C Adaptor kit.

2 Mount the adapting bar using two M8 flat screws . 3 Mount the IP-10C unit on the pole mount bracket, and tighten it using the

four M8 captive screws and washers supplied, with the IP-10C. Thread the screws without fastening. After all four screws are threaded in the correct location, tighten the screws starting from the bottom screws.

4 Connect the Flexible Waveguide and sealing O-Ring supplied with the Flexible Waveguide Imperial kit. Tighten the four metric screws supplied with the RFU-C Adaptor kit.

Page 60: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 60 of 63

5. Appendix A: Mediation Device Losses

IP-10C Mediation Device Losses

Notes: The antenna interface is always the IP-10C interface.

If other antennas are to be used, an adaptor with a 0.1 dB loss should be considered.

Configuration Interfaces 6-8 GHz 11 GHz 13-15 GHz

18-26 GHz

28-42 GHz

Flex WG Remote Mount

antenna Added on remote

mount configurations 0.5 0.5 1.2 1.5 1.5

1+0 DirectMount Integrated antenna 0.2 0.2 0.4 0.5 0.5

1+1 HSB Direct Mount

Main Path 1.6 1.6 1.8 1.8 1.8

with asymmetrical coupler Secondary Path 6 6 6 6 6

2+0 DP (OMT) Direct Mount Integrated antenna 0.5 0.5 0.5 0.5 0.5

2+2 HSB (OMT) Remote Mount

Main Path 1.9 1.9 2.1 2.1 2.1

with asymmetrical coupler Secondary Path 6.5 6.5 6.5 6.5 6.5

2+0/1+1 FD SP Integrated antenna 3.8 3.8 3.9 4 4

4+0 DP (OMT) Remote Mount 4.2 4.2 4.3 4.4 4.4

Page 61: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 61 of 63

6. Appendix B: Test Kit Part Numbers

Band 1+0 1+1 XPIC

6 GHz RFU-C6-TS/NP RFU-C6-TS/P RFU-C6-TS/X

7/8 GHz RFU-C7_8-TS/NP RFU-C7_8-TS/P RFU-C7_8-TS/X

10/11 GHz RFU-C10_11-TS/NP RFU-C10_11-TS/P RFU-C10_11-TS/X

13 GHz RFU-C13-TS/NP RFU-C13-TS/P RFU-C13-TS/X

15 GHz RFU-C15-TS/NP RFU-C15-TS/P RFU-C15-TS/X

18-26 GHz RFU-C18_26-TS/NP RFU-C18_26-TS/P RFU-C18_26-TS/X

28-38 GHz RFU-C28_38-TS/NP RFU-C28_38-TS/P RFU-C28_38-TS/X

42 GHz RFU-C42-TS/NP RFU-C42-TS/P RFU-C42-TS/X

Page 62: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 62 of 63

7. Appendix C: Connector Pin-Outs

This appendix provides pin-outs for FibeAir IDU connectors, including the following:

Management Connector

Power Connector

Ethernet 10/100/1000 Connector

Craft Terminal

7.1 Management Connector Pin-Out

The management connector is an RJ-45, 8-pin, female type connector.

RJ-45 Male Connector Pin

Signal

1 Twisted Pair, Out - Tx

2

3 Twisted Pair, In - Rx

6

4 Not Connected

5

7 Not Connected

8

7.2 Power Connector Pin-Out

The power connector pin-out is as follows:

Left Pin (#1) Right Pin (#2)

-48V (return current) 0V

Note that right/left refers to viewing the panel from the front.

Page 63: FibeAir IP-10C Installation Guide_RevH

FibeAir® IP-10C Installation Guide

Ceragon Proprietary and Confidential Page 63 of 63

7.3 Ethernet 10/100/1000 Connector Pin-Out

The Ethernet 10/100/1000 connector is an RJ-45, 8-pin, female type connector.

RJ-45 Female Connector Pin

Signal

1 Twisted Pair (Tx & Rx)

2

3 Twisted Pair (Tx & Rx)

6

4 Twisted Pair (Tx & Rx)

5

7 Twisted Pair (Tx & Rx)

8

7.4 Craft Terminal Connector Pin-Out

The craft terminal is an RJ-45, 8-pin, female type connector. The following table shows the pin-out values for the RJ-45 craft terminal connector. In addition, the table shows the cross-connect values when using an RJ-45 to DB9 adapter to connect from the IP-10Q’s craft terminal to a DB9 connector.

RJ-45 Female Connector Pin

Name Direction DB9 Cross-Connect

4 SGND – Signal Ground - 5

5 RD – Receive Data In 2

6 TD – Transmit Data Out 3