4
Field Display & Interface Tank inventory anywhere in your tank farm. Honeywell Enraf’s 877 Field Display & Interface Unit (FDI) provides tank inventory information in the field, where it is needed. It is a versatile, EEx-d approved instrument with several interface options, which can even be part of W&M approved applications. The design of the FDI is therefore based on reliable and uninterrupted data supply in all circumstances. The unit can be used in stand alone mode using the Enraf Bi-phase Mark communication protocol for direct connection to any Honeywell Enraf gauge, or any other gauge using this standard communication protocol in tank farms. The unit will interrogate the gauge and display its measured data.

Field Display & Interface - Honeywell Process · Field Display & Interface Tank inventory anywhere in your tank farm. Honeywell Enraf’s 877 Field Display & Interface Unit (FDI)

Embed Size (px)

Citation preview

Field Display & Interface

Tank inventory anywhere in your tank farm.

HoneywellEnraf’s877FieldDisplay&InterfaceUnit(FDI)

providestankinventoryinformationinthefield,whereitis

needed.Itisaversatile,EEx-dapprovedinstrumentwithseveral

interfaceoptions,whichcanevenbepartofW&Mapproved

applications.ThedesignoftheFDIisthereforebasedonreliable

anduninterrupteddatasupplyinallcircumstances.Theunitcan

beusedinstandalonemodeusingtheEnrafBi-phaseMark

communicationprotocolfordirectconnectiontoanyHoneywellEnrafgauge,oranyother

gaugeusingthisstandardcommunicationprotocolintankfarms.Theunitwillinterrogate

thegaugeanddisplayitsmeasureddata.

Technical specifications

Display

Type : LCDcontrastadjustable

2lines,16alphanumericcharactersperline

Decimalseparator : period“.”orcomma“,”selectable

Mechanical

Dimensions(wxhxd) : 225mmx205mmx290mm(87/8”x81/16”x117/16”)

Weight : 12kg(26lb)

Cableentries : 3pcs¾”NPTthreaded(Exdglandsorsealedconduitmayberequired)

Environmental

Ambienttemperature : -40°Cto+60°C(-40°Fto+140°F)

Protectionclass : IP67/NEMA6P

Safety : Explosionproof

II2GEExdIIBT6orEExd[ia/ib]IIBT6accordingtoATEX

-ClassI,Division1,GroupsB,CandD,inacc.toNFPA70(FM,USA)

Materials

Housing : CastaluminumInt.reg.AAA356EN1706AC-AlSi7Mg0.3

Finish : ChromatizedaccordingtoMIL-C-5541C

O-rings : NBR70

Electrical

Powersupply : 110/130/220V(+10%to-20%)and230V(±15%),optional65V(+10%to-20%),

alsosuitablefor240V(+10%to-20%)

Frequencyvariations : 50Hzto60Hz(±10%)

Powerrating : 25VA,Imax=2A(20VAforFM)

Transmission

Type : Serial,Bi-PhaseMarkmodulated(BPM),EnrafGPUprotocol

Isolatingvoltage : >1,500V

Lightningprotection : Fullgalvanicseparationviaisolatingtransformers

Cabling : Twoconductors,twistedpair,Rmax=200Ω/line,Cmax<1µF

CommunicationwithPET* : Infra-red,serial

Operational modes

Sixoff : I Indicatormode(standalone)

F Indicatorandfallbackmode

M Mastermode

D Masterdisplayscanmode(standalone)

H HTGlevelmode

T Standalonetemperaturegauge

Options

Alarmrelayoutput : 2xSPDT,galvanicallyisolated,Vmax=50Vacor75Vdc,Imax=3A(CSA0.6A),

noninductiveload

Fallbackrelay : Adjustabletransmissiontimeout0-29.5min,selfpolling,restartsongaugerestart

Analogleveloutput : 4-20mA(accuracy±0.1%fullscale)

Inputboards : SpotRTD,VITOprobesforaveragetemperatureand/orwatermeasurement,

HART®devices

Datatransmission : StandardModbusviaRS232CorRS485(onlyinoperationmodesH&T)

Cableentries : Adaptersavailabletofitothersizecableglands

HART®isatrademarkoftheHARTCommunicationsFoundation

*)PET=PortableEnrafTerminal

Identification code

Pos 1 ApplicationU GeneralpurposeX W&Mcertified

Pos 2 Data transmissionE EnrafBiphasemarkprotocol(standard)R RS232CGPUprotocol(onlywhenPos3=B,C,J,UorZ)S RS485GPUprotocol(onlywhenPos3=B,C,J,UorZ)V RS232CstandardModbus(onlywhenPos3=B,C,J,UorZ)W RS485standardModbus(onlywhenPos3=B,C,J,UorZ)

Pos 3 I/O optionsB SpottemperaturePt100C VITOtemperatureand/orwaterprobeJ VITOtemperatureand/orwaterprobe+HARTdevice(s)U SpottemperaturePt100+HARTdevice(s)V AnalogleveloutputW Analogleveloutput+VITOtemperatureand/orwaterprobeX Analogleveloutput+VITOtemperatureprobeY Analogleveloutput+spottemperaturePt100+VITOtemperatureand/orwaterprobe+HARTdevice(s)Z None

Pos 4 Alarm relay and fallback relayF WithalarmrelayandfallbackrelayZ Withoutalarmrelayandfallbackrelay

Pos 5, 6, 7 Instrument designation8 7 7 FieldDisplay&Interface

Pos 8 Mains supplyA 220V 50/60HzC 110V 50/60HzK 230V 50/60HzR 130V 50/60HzS 65V 50/60Hz

Pos 9 ApplicationS HIMSifPos3=G,J,UorYT HTGifPos3=G,J,UorYU HTGwithwaterprobeifPos3=JorYZ Basicindicator

Pos 10 Safety approvalsA ATEX EuropeC CSA CanadaF FM USAForotherapprovalspleasecontactyournearestEnrafoffice

U E C F 8 7 7 K Z A Typical identification code

8 7 7 Your identification code

Dimensional drawing

infra redcoupling

Cable entry3 x NPT

180 (7 )

225 (8 )

ø11 ( ) 4x

50(1 )

(3 )100

38

(1

)

290 (11 )

215 (8 )

205

(8

)

170

( 6

)

198

(7

)

(space neededto remove cover)

190 (7 )

100 (4")

Clearance forIR. connector

1/16"

7/8"

7/16"

11/1

6"

13/1

6"

7/16"

7/16"1/2"

1/16

"

15/16"

15/16"

3/4"

1/2"

SerialtransmissionBi-PhaseMarkModulation(BPM)toCIUInventorysystemhostcommunication

SerialtransmissionBi-PhaseMarkModulation(BPM)toCIUInventorysystemhostcommunication

MainsMains

Mains

FDI at the foot of the tank FDI with HTG system

EN-09-18-ENGAugust 2009© 2009 Honeywell International Inc.

For More InformationTolearnmoreaboutHoneywellEnraf’ssolutions,contactyourHoneywellEnrafaccountmanagerorvisitwww.honeywellenraf.com.

AmericasHoneywellEnrafAmericas,Inc.2000NorthfieldCt.Roswell,GA30076USAPhone:+17704751900Email:[email protected]

Europe, Middle East and AfricaHoneywellEnrafDelftechpark392628XJDelftTheNetherlandsPhone:+31(0)152701100Email:[email protected]

Asia PacificHoneywellPteLtd.17ChangiBusinessParkCentral1Singapore486073Phone:+6563552828Email:[email protected]