SIPS SCREWS WITH MINIMUM 1" PENETRATIONIN WOOD MEMBER IN SIP WALL PANELCONNECTED TO @ 24" O.C. MAXIMUM
8d COMMON NAILS@ 6" O.C. EACH SIDE
CONTINUOUS SEALANTAS RECOMMENDED BY MANUFACTURER
CONTINUOUS SEALANTEACH SIDE OF FRAMINGTYP. AS RECOMMENDEDBY MANUFACTURER
CONTINUOUS SEALANTEACH SIDE OF FRAMING TYP.AS RECOMMENDEDBY MANUFACTURER
FOAMCORE
DRYWALL
OUTSIDESKIN
Fig. 2
WALL-TO-WALL PANEL CONNECTIONS
CORNER WALL CONNECTION
8d COMMONNAILS @ 6" O.C.BOTH SIDES
CONCRETEOR MASONRYFOUNDATIONWALL
BE SURE OUTSIDESKIN IS SUPPORTEDBY SILL PLATE
DRAINED ANDVENTILATEDCLADDING
MINIMUM 1/2" (13MM) DIAMETERANCHOR BOLTS @ 6 FEET O.C.MAXIMUM
CONTINUOUS SEALANT EACH SIDE OFFRAMING TYP. AS RECOMMENDED BYMANUFACTURER
TREATEDSILL PLATE
SILL SEALER
16d NAILS INTO SILLPLATE @ 16" O.C.
FIELD INSTALLEDPANEL BOTTOMPLATE
FLOOR JOIST
SIP WALL
SUBFLOOR OR COMBINED SUBFLOORAND UNDERLAYMENT
DRYWALL
TERMITE SHIELD
Fig. 3
FOUNDATION CONNECTION DETAIL A
FOUNDATION CONNECTIONS
MINIMUM 1/2" (13MM) DIAMETER ANCHOR BOLTS@ 6 FEET O.C. MAXIMUM
8d COMMONNAILS @ 6"O.C. EACH SIDE
CONCRETE ORMASONRYFOUNDATIONWALL
CAPILLARY BREAK,MIN. 6 MIL POLY ORMIN. 3/4" PRESSURE-TREATED PLYWOODUNDER SILL PLATEAND BOTH FACES
DRAINED ANDVENTILATEDCLADDING
CONTINUOUS SEALANT EACH SIDE OF FRAMINGTYP. AS RECOMMENDED BY MANUFACTURER
FIELD INSTALLEDTREATED BOTTOMPLATE
DRYWALL
SIP WALL
TERMITE SHIELD
Fig. 4
FOUNDATION CONNECTION DETAIL B
FOUNDATION CONNECTIONS
16d NAILS INTO FLOORJOIST PLATE @ 16" O.C.WHEN USED AS BRACING(3) 16d @ 16” O.C.
ANCHOR BOLT ASREQUIRED BY CODE
CONTINUOUS SEALANTAT EACH SIDE OFFRAMING TYP. ASRECOMMENDED BYMANUFACTURER
MANUFACTURERSRECOMMENDATIONS
SPACING
OR MASONRYFOUNDATION WALL
6 MIL POLY OR MIN.3/4" PRESSURE-TREATED PLYWOODUNDER SILL PLATE AND BOTH FACES
TREATEDSILL PLATE
NAILS @ 6"SUBFLOOR OR COMBINED SUBFLOORAND UNDERLAYMENT, TYP.
FLOOR JOIST
TREATED BOTTOM
DRYWALL
DRAINED ANDVENTILATEDCLADDING
SIP WALL
USE NAILS PER
FOR SIZE AND
CONCRETE
CAPILLARY BREAK, MIN.
8d COMMON
O.C. EACH SIDE
FIELD INSTALLED
PLATE
Fig. 5
FOUNDATION CONNECTIONS
FOUNDATION CONNECTION DETAIL C
DRYWALL
STRUCTURAL SUPPORT MEMBER WITHMIN. 1-1/2" BEARING FOR EACH SIDE OFPANELS
SEALANT ASRECOMMENDED BYMANUFACTURER
INSTALLED WOOD
SIPS SCREWS WITH 1"MIN. PENETRATION INTOSTRUCTURAL SUPPORT@ 24" O.C. MINIMUM
SIP TAPE ATRIDGE REQUIRED
8d COMMON
O.C. BOTH SIDES
FINISH ROOFING MATERIAL
EACH SIDE OF FRAMING
AS RECOMMENDEDBY MANUFACTURER
ROOFING FELT
FOAM RIDGE CAP
SIP ROOFPANEL
CONTINUOUS FIELD
RIDGE SUPPORTBEAM SHOWN
NAILS @ 6"
CONTINUOUS SEALANT
AND BOTH FACES
Fig. 6
ROOF-TO-ROOF PANEL CONNECTIONS
FOAM RIDGE CAP DETAIL
SIPS SCREWS W/ MINIMUM 1"PENETRATION INTOSTRUCTURAL SUPPORT@ 24" O.C. MINIMUM
RIDGE SUPPORTBEAM
SIP TAPE ATRIDGE REQUIRED
ROOFINGFELT
FINISHEDROOFINGMATERIAL
MINIMUM 3/8" GAPFOR SEALANT ASRECOMMENDED BYMANUFACTURER
BLOCKING AS REQUIREDBY STRUCTURAL CONDITIONS
Fig. 7
ROOF-TO-ROOF PANEL CONNECTIONS
BEVELED SIP RIDGE DETAIL
DRAINED ANDVENTILATEDCLADDING
SIP WALL PANEL
TOP PLATE
ROOFINGFELT
DRYWALL
SIP ROOFPANEL
PANEL SCREW
FINISHEDROOFINGMATERIAL
8d COMMON NAILS@ 6" O.C. EACH SIDECONTINUOUS
SIDE OF FRAMING
BY MANUFACTURER,AND ROOF PANEL
SEALANT EACH
AS RECOMMENDED
2x JOINT
Fig. 8
ROOF-TO-WALL PANEL CONNECTIONS
BEVELED SIP WALL
CONTINUOUS SEALANT EACH SIDEOF FRAMING AS RECOMMENDED BYMANUFACTURER
DRYWALLCONTINUOUS SEALANT EACH SIDEOF FRAMING AS RECOMMENDED BYMANUFACTURER
8d COMMON NAILS@ 6" O.C. BOTH SIDES
DRAINED ANDVENTILATEDCLADDING
SIP WALL PANEL
TOP PLATE
WEDGE INFILL PIECE
SIP ROOFPANEL
ROOFINGFELT
PANEL SCREW
FINISHEDROOFINGMATERIAL
CONTINUOUSSEALANT EACHSIDE OF FRAMING,AND ROOF PANEL2x JOINT
Fig. 10
ROOF-TO-WALL PANEL CONNECTIONS
WEDGE INFILL PIECE
6" O.C. BOTH SIDESCONTINUOUS SEALANT BOTH SIDESTYP. OF FRAMING AS RECOMMENDEDBY MANUFACTURER
SIP TAPE ATRIDGE REQUIRED
FINISHED ROOFINGMATERIAL
CONTINUOUS SEALANT TYPICALAS RECOMMENDED BYMANUFACTURER
8d COMMON NAILS
ROOFINGFELT
@ 16" O.C.16d COMMON NAILS
Fig. 11
RIDGE DETAIL AT CANTILEVER (LIMIT 2' OVERHANG)
ROOF-TO-ROOF PANEL CONNECTIONS
16d COMMON NAILS @ 16" O.C.WHEN USED AS BRACING (3) 16dCOMMON NAILS @ 16" O.C.
CONTINUOUS SEALANT EACH SIDE OFFRAMING TYP. AS RECOMMENDED BYMANUFACTURER
TOP FLANGE METAL FLOOR JOISTHANGAR (BY OTHERS)
FLOOR JOISTS
3/4" T&G FLOOR SHEATHING(GLUED & NAILED) TO EXTENDOVER TOP OF SIP WALL
STANDARD WIRE CHASE
METAL STRAPAS REQUIREDOR LTP4SIMPSON CLIP
CAP PLATE
CONTINUOUS SEALANTEACH SIDE OF FRAMINGTYP. AS RECOMMENDED BYMANUFACTURER
DRYWALL
8d COMMONNAILS @ 6"O.C. BOTH SIDES
2x BOTTOMPLATE
DRAINED ANDVENTILATEDCLADDING
SIP WALLPANEL
DRYWALL
FIRST FLOOR
SECOND FLOOR
Fig. 12
2ND FLOOR CONNECTION DETAILS
HANGING FLOOR
FLOOR JOISTS (I-JOIST SHOWN)
3/4" T&G FLOOR SHEATHING(GLUED & NAILED) TO EXTENDOVER TOP OF SIP WALL
16d COMMON NAILS @ 16" O.C.WHEN USED AS BRACING (3) 16dCOMMON NAILS @ 16" O.C.
CONTINUOUS SEALANT EACH SIDE OFFRAMING TYP. AS RECOMMENDED BYMANUFACTURERBOTH SIDES
8d COMMONNAILS @ 6" O.C.BOTH SIDES
DRAINED ANDVENTILATEDCLADDING
2x BOTTOMPLATE
SIP WALLPANEL
METAL LATERALTIE PLATE NAILEDTO BOTTOM ORSHIM PLATES ANDRIM BOARD
METAL LATERALTIE PLATE NAILEDTO BOTTOM ORSHIM PLATES ANDRIM BOARD
RIM BOARD
FIRST FLOOR
INSULATION
DRYWALL
STANDARD WIRE CHASE
8d COMMONNAILS @ 6" O.C.
CAP PLATE AS REQUIREDBY MANUFACTURER
CONTINUOUS SEALANT EACH SIDEOF FRAMING TYP. AS RECOMMENDEDBY MANUFACTURER
DRYWALL
SECOND FLOOR
Fig. 13
RIM BOARD
2ND FLOOR CONNECTION DETAILS
AS REQUIRED, EXTEND ICEAND WATER SHIELD FROMFASCIA.
CONTINUOUSSEALANT EACH SIDEOF FRAMING TYP. ASRECOMMENDED BYMANUFACTURER
SOFFIT BOARD
DRIPEDGEFLASHING
FASCIA
CONTINUOUS SEALANT ASRECOMMENDED BYMANUFACTURER
ROOF-TO-WALL PANELCONNECTION DETAILSHOWN ELSEWHERE
ROOFING FELT
FINISHED ROOFING MATERIAL
SIP ROOF PANEL
Fig. 14
EAVES DETAIL A
EAVES DETAILING
SIP SCREW
SOFFIT BOARD
AS REQUIRED, EXTEND ICEAND WATER SHIELD FROMFASCIA
CONTINUOUS SEALANTEACH SIDE OF FRAMINGTYP. AS RECOMMENDEDBY MANUFACTURER
2X BLOCKINGTO SUPPORTFASCIA BOARD
FASCIA
DRIP EDGEFLASHING
2x FRAMING MEMBER
CONTINUOUS SEALANT ASRECOMMENDED BYMANUFACTURER
8d COMMON NAILS@ 6" O.C. BOTH SIDES
ROOF-TO-WALL PANEL CONNECTIONDETAIL SHOWN ELSEWHERE
SIP ROOF PANEL
FINISHED ROOFING MATERIAL
ROOFING FELT
Fig. 15
EAVES DETAIL B
EAVES DETAILING
SIP ROOF PANEL
DRIP EDGE
CONTINUOUS SEALANT EACHSIDE OF FRAMING TYP.RECOMMENDED BY
AS REQUIRED, EXTEND ICEAND WATER SHIELD FROMFASCIA.
FINISHED ROOFING MATERIAL
2x FRAMING MEMBER
2x FRAMING MEMBER
SOFFIT BOARDFASCIA
8d COMMON NAILS@ 6" O.C. BOTH SIDES
CONTINUOUS SEALANTRECOMMENDED BYMANUFACTURER
USE NAILS PER MANUFACTURER'SRECOMMENDATIONS FOR SIZE ANDSPACING.
ROOFING FELT
SIP SCREW
Fig. 16
EAVES DETAILING
EAVES DETAIL C
BEVELED
TO SUPPORTFASCIA BOARD
CONTINUOUS SEALANT EACHSIDE OF FRAMING TYP. ASRECOMMENDED BYMANUFACTURER
DRIP EDGEFLASHING
AS REQUIRED, EXTEND ICEAND WATER SHIELD FROMFASCIA
SOFFIT BOARD
FASCIA
SIP ROOF PANEL
ROOFING FELT
FINISHED ROOFING MATERIAL
USE NAILS PER MANUFACTURER'SRECOMMENDATIONS FOR SIZE ANDSPACING.
8d COMMON NAILS@ 6" O.C. BOTHSIDES
CONTINUOUS SEALANTAS RECOMMENDED BYMANUFACTURER
ROOF-TO-WALL PANELCONNECTION DETAILSHOWN ELSEWHERE
BLOCKING
Fig. 17
EAVES DETAILING
EAVES DETAIL D
USE NAILS PER MANUFACTURER'SRECOMMENDATIONS FOR SIZE ANDSPACING.
CONTINUOUS SEALANTAS RECOMMENDED BYMANUFACTURER
ROOF-TO-WALL PANEL CONNECTIONDETAIL SHOWN ELSEWHERE
8d COMMON NAILS @6" O.C. BOTH SIDES
AS REQUIRED, EXTEND ICEAND WATER SHIELD FROMFASCIA
CONTINUOUS SEALANT EACHSIDE OF FRAMING TYP. ASRECOMMENDED BY
DRIP EDGE
FINISHED ROOFING MATERIAL
FASCIA
SOFFIT BOARD
SIP ROOF PANEL
ROOFING FELT
Fig. 18
EAVES DETAIL E
EAVES DETAILING
CONTINUOUS SEALANT EACHSIDE OF FRAMING TYP. ASRECOMMENDED BYMANUFACTURER
EXPANSION GAP 1/8"
CHASE FOR EXPANDEDFOAM SEALANT
8d COMMON NAILS@ 6" O.C. EACH STRIPAND EACH SIDE
SIP PANEL
SEALANT AS RECOMMENDEDBY MANUFACTURER
Fig. 19
WALL-TO-WALL VERTICAL PANEL CONNECTIONS
SURFACE SPLINE FOR VERTICAL SPLICE
EXPANSION GAP 1/8"
8d COMMON NAILS@ 6" O.C. EACH PANELAND EACH SIDE
(2) ROWS 16d COMMONNAILS@ 16" O.C. MINIMUM
SIP PANEL
CONTINUOUS SEALANT EACHSIDE OF FRAMING TYP. ASRECOMMENDED BYMANUFACTURER
Fig. 20
WALL-TO-WALL VERTICAL PANEL CONNECTIONS
DIMENSIONAL LUMBER SPLINE
VALLEYFLASHING
8d COMMON NAILS @6" O.C. EACH PANELAND EACH SIDE
CONTINUOUS SEALANTEACH SIDE OF FRAMINGTYP. ASRECOMMENDED BYMANUFACTURER ATSUPPORT MEMBERS
16d COMMONNAILS @ 16"O.C. MINIMUM
SIP ROOF PANEL
DRYWALL
CONTINUOUS SEALANTEACH SIDE OF FRAMINGTYP. AS RECOMMENDEDBY MANUFACTURER
STRUCTURAL SUPPORT
SIP TAPESIPS SCREWW/ MINIMUM 1"PENETRATIONINTO STRUCTURALSUPPORT
DOUBLE 2x SPLINEBEVEL CUT
Fig. 22
ROOF-TO-ROOF PANEL CONNECTIONS
VALLEY DETAIL