2
Hewitech`s film fills made with a direct inline foil-forming and final thermo-welding assembly process grant a very robust fill structure for a long lifespan. Controllable foil thickness enables fill stabilies and material adapon to be opmized to customers specificaon. The low drop pressure and the specific design generate a proven reducon of water loss in the cooling process. Driſt eliminator film series Effecve reducon of water loss in cooling processes Design Diversity · Sustainable Efficiency · Custom-made Soluon www.hewitech.de Features · Made of PP, solvent free, UV resistant · Eurovent cerfied · High droplet separaon · Very low pressure drop · Good mechanical strength with different foil thickness · Easy and fast installaon of compact elements · Mulple welding point for long lifeme DE 125 Small and medium size cooling towers demand efficient driſt eliminator systems to significantly reduce water losses caused by upstreaming air above the cooling fill. These film driſt eliminator elements are easy to install and can be dismantled and cleaned for further use in the cooling tower.

Film Drift Eliminator 25.01. · 2020-02-25 · the cooling fill. These film drift eliminator elements are easy to install and can be dismantled and cleaned for further use in the

  • Upload
    others

  • View
    9

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Film Drift Eliminator 25.01. · 2020-02-25 · the cooling fill. These film drift eliminator elements are easy to install and can be dismantled and cleaned for further use in the

Hewitech`s film fills made with a direct inline foil-forming

and final thermo-welding assembly process grant a very

robust fill structure for a long lifespan.

Controllable foil thickness enables fill stabilities and

material adaption to be optimized to customers

specification. The low drop pressure and the specific

design generate a proven reduction of water loss in the

cooling process.

Drift eliminator film seriesEffective reduction of water loss in cooling processes

Design Diversity · Sustainable Efficiency · Custom-made Solutionwww.hewitech.de

Features

· Made of PP, solvent free, UV resistant

· Eurovent certified

· High droplet separation

· Very low pressure drop

· Good mechanical strength with different foil

thickness

· Easy and fast installation of compact elements

· Multiple welding point for long lifetime

DE 125

Small and medium size cooling towers demand efficient drift eliminator systems to significantly reduce water losses caused by upstreaming air above the cooling fill. These film drift eliminator elements are easy to install and can be dismantled and cleaned for further use in the cooling tower.

Page 2: Film Drift Eliminator 25.01. · 2020-02-25 · the cooling fill. These film drift eliminator elements are easy to install and can be dismantled and cleaned for further use in the

DE 250

Film drift eliminator series

This general information about technical data and descriptions of our products has been put together with greatest care. We reserve the rights of any changes without further notice. We recommend to re-check data before using in final project designs. All data without obligations and consequences due to non-compliance.

HEWITECH drift eliminator systems with certified drift rates

Water Quality Structure Code MaterialTechnical Data

[mm]L x W x H

slightly / moderatelypolluted

DE 125 PP & PVC 2.400 x 600 x 125

slightly / moderatelypolluted

DE 250 PP & PVC 2.400 x 600 x 250

HEWITECH drift eliminator system with adjusted strenght

Design Structure Code Ratio sheets

DE 125 F11:1

flat /corrugated

DE 125 F31:3

flat /corrugated

DE 125 F51:5

flat /corrugated

Hewitech GmbH & Co KG - Am Langenhorster Bahnhof 16 - D-48607 Ochtrup/Germany +49 2553 97 02 60 · [email protected] · www.hewitech.de

Technical information· Material: Polypropylene (PP) or Polyvinylchloride (PVC)

· Color: anthracite with UV resistant

· Resistant to dissolved various chemicals, fungi and rot

resistant

· Maximal operation temperature:

75 °C (PP) and 55 °C (PVC) (higher on request)

· Tolerances: max 2%

· On request special flame retardant

ASTM E84 and DIN 4102 (other norms on request)

· Length of elements >2400mm on request

We provide droplet eliminators in different shape designs

in order to reduce the construction cost in smaller coo-

ling tower units basically by optimization of the support

system of eliminator sector.

The static of DE elements improved by adjustable foil

thickness and free selected sequence of flat foils. Our

Standard design is produced with a ratio of 1:7 flat to

corrugated sequence.

On request we produce nested DE elements with one flat

and one corrugated ending sheet per element.