Index
Technical data 1
Filters series UCMF 40 2
Filters series UCMF 65-75-85-100 4
Filters series UCMF 150-200 6
Filters series UCMF 280-300-350 8
Accessories 10
Spare parts 11
Uni-Cardan Italia S.p.A. reserves the right to make technical
changes to the products without notice.
The products shown in this catalogue have been developed
by Uni-Cardan Italia S.p.A., a company owned by
GKN Automotive.
1
Return line Filters Series UCMF
Description
UCMF series filters are suitable for applications on the return line of hydraulic circuits, installed semi-immersed in the oil tank.They are available with connection ports from 1/2" up to 2" and flow rate from 30 up to 400 l/min.The filters series UCMF are supplied as standard with By-pass valve in the cartridge.
Technical data complete filter
l Filter head and cap in aluminium alloyl Bowl in fiber glass reinforced Nylon or steell Max working pressure = 3 barl Max test pressure = 6 barl Burst pressure = 10 barl Differential collapse pressure filter elements = 3 barl By-pass valve set at 1,7 bar ± 10%l Working temperature -25°C up to +95°Cl Connections: BSP - NPT - SAE threaded ports from 1/2" up to 2"
Technical data filter elements
l A/B: paper treated with resin, filtration rating 10 and 25 microns βx ≥ 2l F/N/G/H: inorganic fibres, filtration rating 3, 6, 10 and 25 microns βx ≥ 200l L: stainless steel square wire mesh (AISI 304), filtration rating 60 micronsl C/E: brash square wire mesh, filtration rating 90 and 125 micronsl End cap in Polyamidel Support tube in galvanized steell Support mesh in galvanized steel with epoxy coating
Filter elements are manufactured in accordance with the following ISO standards:
l ISO 4572 Filtration performance valuated with Multi-pass testl ISO 2941 Verification of collapse/burst resistancel ISO 2942 Verification of fabrication integrity and determination of the first bubble pointl ISO 2943 Compatibility of materials with fluids (type HH, HM, HR, HV, HG according with ISO 6743/4)l ISO 3723 Method for the end load testl ISO 3724 Verification of flow fatigue characteristicsl ISO 3968 Evaluation of pressure drop versus flow characteristics
Filters series UCMF 40
2
By-pass valve pressure drop
By-pass valve pressure drop
All the curves have been obtained with mineral oil with a
density of 860 Kg/m 3. The pressure drop is proportional to the
variation of density.
Pressure drop (in accordance with ISO 3968)
The assembly pressure drop is obtained by adding the
pressure drop of the filter housing with the pressure drop of
the filter element.
Filter Housing pressure drop
Housing pressure drop
All the curves have been obtained with mineral oil with a
density of 860 Kg/m 3. The pressure drop is proportional to the
variation of density.
D
E
F
B
C
M
L
A
I
H
G
D
E
Cartridge series CMF
Size
Type A* B C D E F G H I L M WeightKg
UCMF 40 1/2” 66 86 90 7 24,5 8 50 26 21 133 0,4
Type
Filtration area (cm2)
10 µ - 25 µßx ≥ 2
60 µ - 90 µ 125 µ
3 µ - 6 µ - 10 µ - 25 µßx ≥ 200
CMF 40 823 280 380
Threaded ports see order module*
Cartridge Filter element Flowl/min
CMF 40
A 40
B 40
F 18
N 19
G 27
H 37
Flow rate [l/min]
00 10 20 30 40 50 60 70 80 90 100
24
68
10121416
18
20
Portata/Flow rate [l/min]
�p KPaUCMF 40
1/2"
Flow rate [l/min]
00 10 20 30 40 50
50
150
100
200
250
300
350
Portata/Flow rate [l/min]
�p KPaUCMF 40
Filter elements pressure drop
Pressure drops in the filtering elements
All the curves have been obtained using mineral oil with
kinematic viscosity of 30 cSt. The pressure drop is
proportional to the variation of kinematic viscosity.
3
How to order the
complete filter
Flow rate [l/min]
00
10
20
30
40
50
10 20 30 40 6050
Portata/Flow rate [l/min]
�p KPaCMF 40 F N G H
Flow rate [l/min]
00
10
20
30
40
50
10 20 30 40 50 60
Portata/Flow rate [l/min]
�p KPaCMF 40 A
B-L
CE
Series
Return line complete filter
Seals
NNitrile
Buna-N
V Viton
Port
- 1/2” BSP
1 1/2" NPT
2SAE 8 - 3/4"
16 UNF
Cap setting
_ Indicator port 1/8" BSP
N Indicator port 1/8" NPT
F Indicator port 1/8" BSP and filling plug
FNIndicator port 1/8" NPT and filling plug
Filter element
_ Without filter element
A Paper treated with resin 10 µ ßx ≥ 2
B Paper treated with resin 25 µ ßx ≥ 2
C Brass square wire mesh 90 µ
E Brass square wire mesh 125 µ
F Inorganic fibre 3 µ ßx ≥ 200
G Inorganic fibre 10 µ ßx ≥ 200
H Inorganic fibre 25 µ ßx ≥ 200
L Square wire mesh in inox (AISI 304) 60 µ
N Inorganic fibre 6 µ ßx ≥ 200
Size
U C M F 4 0 A N F 1
By-pass valve pressure drop
By-pass valve pressure drop
All the curves have been obtained with mineral oil with a
density of 860 Kg/m 3. The pressure drop is proportional to the
variation of density.
Filter Housing pressure drop
Housing pressure drop
All the curves have been obtained with mineral oil with a den-
sity of 860 Kg/m 3. The pressure drop is proportional to the
variation of density.
Filters series UCMF 65-75-85-100
4
Pressure drop (in accordance with ISO 3968)
The assembly pressure drop is obtained by adding the
pressure drop of the filter housing with the pressure drop of
the filter element.
D
E
F
B
C
M
L
A
I
H
G
D
E
Cartridge series CMF
Threaded ports see order module*
Size
Type A* B C D E F G H I L MWeight
Kg
UCMF 65 1/2”
86
105
115 9 30 10 67 34 29
1680,715
UCMF 753/4”
0,715
UCMF 85150 211
0,77
UCMF 100 1” 0,77
Type
Filtration area(cm2)
10 µ - 25 µßx ≥ 2
60 µ - 90 µ 125 µ
3 µ - 6 µ - 10 µ - 25 µßx ≥ 200
CMF 65 1443 450 820
CMF 100 2225 700 1260
Cartridge Filter element Flowl/min
CMF 65
A 81
B 81
F 31
N 34
G 39
H 58
CMF 100
A 100
B 100
F 37
N 42
G 55
H 92
Flow rate [l/min]Portata/Flow rate [l/min]
�p KPaUCMF 65-75-85-100
00 20 40 60 80 100 120 140 160 180 200
2
46810
1214
161820
1/2" 3/4"
1"
Portata/Flow rate [l/min]
�p KPa
00 25 75 100 125 150 175 20050
50
100
150
200
250
300
350UCMF 65-75-85-100
Flow rate [l/min]
Filter elements pressure drop
Pressure drops in the filtering elements
All the curves have been obtained using mineral oil with
kinematic viscosity of 30 cSt. The pressure drop is
proportional to the variation of kinematic viscosity.
5
How to order the
complete filter
Portata/Flow rate [l/min]
�p KPaCMF 65
0
10
20
30
40
50
020 40 60 80 100 120
A
B
LC-E
Flow rate [l/min]
Portata/Flow rate [l/min]
�p KPaCMF 100
00 25 50 75 100 125 150
10
20
30
40
50
A
BL
C-E
Flow rate [l/min]
Portata/Flow rate [l/min]
�p KPa CMF 6550
40
30
20
10
00 10 20 30 40 50 60
N G
H
F
Flow rate [l/min]
Portata/Flow rate [l/min]
�p KPaCMF 100
00 10 20 30 40 50 60 70 80
10
20
30
40
50F N G
H
Flow rate [l/min]
U C M F 1 0 0 A N F 1
Size
65
75
85
100
Port
- 1/2” BSP
1 3/4" BSP
2 1" BSP
3 1/2" NPT
4 3/4" NPT
5 1" NPT
6SAE 8 - 3/4"
16 UNF
7SAE 12 - 1 1/16"
12 UN
8SAE 16 - 5 1/16"
12 UN
Series
Return line complete filter
Seals
NNitrile
Buna-N
V Viton
Cap setting
_ Indicator port 1/8" BSP
N Indicator port 1/8" NPT
F Indicator port 1/8" BSP and filling plug
FNIndicator port 1/8" NPT and filling plug
Filter element
_ Without filter element
A Paper treated with resin 10 µ ßx ≥ 2
B Paper treated with resin 25 µ ßx ≥ 2
C Brass square wire mesh 90 µ
E Brass square wire mesh 125 µ
F Inorganic fibre 3 µ ßx ≥ 200
G Inorganic fibre 10 µ ßx ≥ 200
H Inorganic fibre 25 µ ßx ≥ 200
L Square wire mesh in inox (AISI 304) 60 µ
N Inorganic fibre 6 µ ßx ≥ 200
By-pass valve pressure drop
By-pass valve pressure drop
All the curves have been obtained with mineral oil with a
density of 860 Kg/m 3. The pressure drop is proportional to the
variation of density.
Filter Housing pressure drop
Housing pressure drop
All the curves have been obtained with mineral oil with a
density of 860 Kg/m 3. The pressure drop is proportional to the
variation of density.
Filters series UCMF 150-200
6
Pressure drop (in accordance with ISO 3968)
The assembly pressure drop is obtained by adding the
pressure drop of the filter housing with the pressure drop of
the filter element.
Cartridge series CMF
D
E
F
B
C
M
L
A
I
H
G
120 �
D
E
45�
Size
Type A* B C D E F G H I L MWeight
Kg
UCMF 150 1”129 244 175 11 40 10 95 45 35 324
1,94
UCMF 200 1 1/4” 1,94
Type
Filtration area(cm2)
10 µ - 25 µßx ≥ 2
60 µ - 90 µ 125 µ
3 µ - 6 µ - 10 µ - 25 µßx ≥ 200
CMF 200 6922 1870 3780
Threaded ports see order module*
Portata/Flow rate [l/min]
�p KPa UCMF 150-200
00
5
10
15
20
25
30
30 60 90 120 150 180 210 240 270 300
1 1/4"
1"
Flow rate [l/min]
Portata/Flow rate [l/min]
�p KPaUCMF 150-200
00
50
100
150
200
250
300
350
100 200 300 400 500
Flow rate [l/min]
Cartridge Filter element Flowl/min
CMF 200
A 214
B 214
F 109
N 124
G 157
H 174
Filter elements pressure drop
Pressure drops in the filtering elements
All the curves have been obtained using mineral oil with
kinematic viscosity of 30 cSt. The pressure drop is
proportional to the variation of kinematic viscosity.
7
How to order the
complete filter
Portata/Flow rate [l/min]
�p KPaCMF 200
2001801601401008060402000
50
40
30
20
10
120
F N
G
H
Flow rate [l/min]
Portata/Flow rate [l/min]
�p KPaCMF 200
00
50
40
30
20
10
30 60 90 120 150 180 210 240 270 300
A
B-LC-E
Flow rate [l/min]
U C M F 1 5 0 A N F 1
Size
150
200
Port
- 1" BSP
1 1 1/4" BSP
2 1" NPT
3 1 1/4" NPT
4SAE 16 - 5 1/16"
12 UN
5SAE 20 - 1 5/8"
12 UN
Series
Return line complete filter
Seals
NNitrile
Buna-N
V Viton
Cap setting
_ Indicator port 1/8" BSP
N Indicator port 1/8" NPT
F Indicator port 1/8" BSP and filling plug
FNIndicator port 1/8" NPT and filling plug
Filter element
_ Without filter element
A Paper treated with resin 10 µ ßx ≥ 2
B Paper treated with resin 25 µ ßx ≥ 2
C Brass square wire mesh 90 µ
E Brass square wire mesh 125 µ
F Inorganic fibre 3 µ ßx ≥ 200
G Inorganic fibre 10 µ ßx ≥ 200
H Inorganic fibre 25 µ ßx ≥ 200
L Square wire mesh in inox (AISI 304) 60 µ
N Inorganic fibre 6 µ ßx ≥ 200
By-pass valve pressure drop
By-pass valve pressure drop
All the curves have been obtained with mineral oil with a
density of 860 Kg/m 3. The pressure drop is proportional to the
variation of density.
Filter Housing pressure drop
Housing pressure drop
All the curves have been obtained with mineral oil with a
density of 860 Kg/m 3. The pressure drop is proportional to the
variation of density.
Filters series UCMF 280-300-350
8
Pressure drop (in accordance with ISO 3968)
The assembly pressure drop is obtained by adding the
pressure drop of the filter housing with the pressure drop of
the filter element.
D
E
F
B
C
M
L
A
I
H
G
120 �
45�
D
E
Cartridge series CMF
Size
Type A* B C D E F G H I L MWeight
Kg
UCMF 280 1 1/4”
173
176
220 1151
11 120 48 38
260 3,25
UCMF 300 1 1/2” 236 320 3,7
UCMF 350 2” 282 64 368 3,9
Type
Filtration area(cm2)
10 µ - 25 µßx ≥ 2
60 µ - 90 µ 125 µ
3 µ - 6 µ - 10 µ - 25 µßx ≥ 200
CMF 280 6710 1870 3280
CMF 300 9627 2700 7400
CMF 350 12056 3800 9300
Threaded ports see order module*
Cartridge Filter element Flowl/min
CMF 280
A 276B 276F 120N 146G 178H 300
CMF 300
A 319B 319F 165N 192G 250H 350
CMF 350
A 380B 380F 264N 295G 341H 500
Portata/Flow rate [l/min]
�p KPaUCMF 280-300-350
00
40
35
30
25
20
15
10
5
100 200 300 400 500 600
1 1/4"
1 1/2"
1"
Portata/Flow rate [l/min]
�p KPaUCMF 280-300-350
50000
50
350
300
250
200
150
100
100 200 300 400
Flow rate [l/min]
Flow rate [l/min]
Filter elements pressure drop
Pressure drops in the filtering elements
All the curves have been obtained using mineral oil with
kinematic viscosity of 30 cSt. The pressure drop is
proportional to the variation of kinematic viscosity.
9
How to order the
complete filter
Portata/Flow rate [l/min]
�p KPaCMF 280
00
10
20
30
40
50
50 100 150 200 250 300
F N G
H
Portata/Flow rate [l/min]
�p KPaCMF 280
50000
10
20
30
40
50
100 200 300 400
A
BLC-E
Portata/Flow rate [l/min]
CMF 300�p KPa
00 50 100 150 200 250 300 350 400
10
20
30
40
50F N G
H
Portata/Flow rate [l/min]
�p KPaCMF 300
00
10
20
30
40
50
100 200 300 400 500 600
B
A
LC-E
Portata/Flow rate [l/min]
CMF 350 F N G
H
�p KPa
00 100 200 300 400 500 600
10
20
30
40
50
CMF 350
B
A
LC-E
Portata/Flow rate [l/min]
0 100 200 300 400 500 600
�p KPa
0
10
20
30
40
50
Flow rate [l/min]
Flow rate [l/min]
Flow rate [l/min]
Flow rate [l/min]
Flow rate [l/min]
Flow rate [l/min]
Series
Return line complete filter
Seals
NNitrile
Buna-N
V Viton
Filter element
_ Without filter element
A Paper treated with resin 10 µ ßx ≥ 2
B Paper treated with resin 25 µ ßx ≥ 2
C Brass square wire mesh 90 µ
E Brass square wire mesh 125 µ
F Inorganic fibre 3 µ ßx ≥ 200
G Inorganic fibre 10 µ ßx ≥ 200
H Inorganic fibre 25 µ ßx ≥ 200
L Square wire mesh in inox (AISI 304) 60 µ
N Inorganic fibre 6 µ ßx ≥ 200
Port
- 1 1/4" BSP
1 1 1/2" BSP
2 2" BSP
3 1 1/4" NPT
4 1 1/2" NPT
5 2" NPT
6SAE 20 - 1 5/8"
12 UN
7SAE 24 - 1 7/8"
12 UN
U C M F 2 8 0 A N F 1
Size
280
300
350
Cap setting
_ Indicator port 1/8" BSP
N Indicator port 1/8" NPT
F Indicator port 1/8" BSP and filling plug
FNIndicator port 1/8" NPT and filling plug
UCFB
Pressure gauge with scale from 0 to 12 bar
UCFD
Pressure switch with N.O. contacts set at 1,3 bar ± 10%
UCFE
Pressure switch with N.C. contacts set at 1,3 bar ± 10%
UCFH
Membrane pressure switch with change over contacts set at 1,3 bar ± 10%
U C F B
10
Accessories
Clogging indicators
Filling plug
Ø40
UCF-B
1/8" BSP
46
Ø40
UCF-C
46
1/8" BSP
UCF-DUCF-E
1/8" BSP
66
UCF-H62
52
1/8" BSP
65
UCF-GUCF-G4VDI -GVDI -G4
UCF-FUCF-F4VDI-FVDI-F4
U.C.F. 40
UCF-FRVDI-FR
U.C.F.
Ø40
UCF-B
1/8" BSP
46
Ø40
UCF-C
46
1/8" BSP
UCF-DUCF-E
1/8" BSP
66
UCF-H62
52
1/8" BSP
65
UCF-GUCF-G4VDI -GVDI -G4
UCF-FUCF-F4VDI-FVDI-F4
U.C.F. 40
UCF-FRVDI-FR
U.C.F.
Ø40
UCF-B
1/8" BSP
46
Ø40
UCF-C
46
1/8" BSP
UCF-DUCF-E
1/8" BSP
66
UCF-H62
52
1/8" BSP
65
UCF-GUCF-G4VDI -GVDI -G4
UCF-FUCF-F4VDI-FVDI-F4
U.C.F. 40
UCF-FRVDI-FR
U.C.F.
T
Symbol
With By-pass
A
B
A A
B B
A
B
A A
B B
23
1
N.A.
N.C.
C
23
1
N.A.
N.C.
C
A
B
A A
B B
A
B
A A
B B
23
1
N.A.
N.C.
C
23
1
N.A.
N.C.
C
A
B
A A
B B
A
B
A A
B B
23
1
N.A.
N.C.
C
23
1
N.A.
N.C.
C
UCF-B UCF-DUCF-EUCF-H
Size T
UCMF 40 1/4" BSP
UCMF 65
3/8" BSPUCMF 75
UCMF 85
UCMF 100
UCMF 1501/2" BSP
UCMF 200
UCMF 280
3/4" BSPUCMF 300
UCMF 350
How to order
Spare parts
Cartridge series CMF
11
How to order
Cartridge size
CMF Return filter UCMF
T
SizeReturn line
complete filter
40 UCMF 40
65 UCMF 65 - UCMF 75
100 UCMF 85 - UCMF 100
200 UCMF 150 - UCMF 200
280 UCMF 280
300 UCMF 300
350 UCMF 350
C M F 3 5 0 A N
Seals
NNitrile
Buna-N
V Viton
Filter element
A Paper treated with resin 10 µ ßx ≥ 2
B Paper treated with resin 25 µ ßx ≥ 2
C Brass square wire mesh 90 µ
E Brass square wire mesh 125 µ
F Inorganic fibre 3 µ ßx ≥ 200
G Inorganic fibre 10 µ ßx ≥ 200
H Inorganic fibre 25 µ ßx ≥ 200
L Square wire mesh in inox (AISI 304) 60 µ
N Inorganic fibre 6 µ ßx ≥ 200
HANDLE