A-A ( 1 : 20 )
B ( 1 : 5 )
A A
B
QUANTITY: FINISH:
NEW BIN LIFT DESIGN
TITLE:
GENERAL ARRANGEMENT
JOB NO.:
A1
SIZE:
hannos
DRAWN: DRG. NO.:CODE:
SCALE:
1 : 50
DATE:
7/09/2015
DXF FILE:
~BIN-LIFT.GA.idw
FILENAME:
ALL DIMENSIONS
IN mm UNLESS
STATED OTHERWISE
SERIAL NO.:
C:\P
ro
je
ct w
ork are
a\B
IN
LIF
T\B
IN
L
IF
T 2
.0.IN
VE
NT
OR
\~
BIN
-L
IF
T.G
A.idw
- S
he
et # 1
HOIST SPECIFICATIONS
MODEL: TBL1000
CAPACITY: 1000kg
LOWERED HEIGHT: 80mm
TRAVEL: 2300mm
SPEED (NOMINAL): 2.0 m/minute
TRAVEL TIME: 70 seconds
PLATFORM LENGTH: 1050mm
PLATFORM WIDTH: 1210mm
FLOOR FINISH: CHEQUER PLATE
CONTROLS:
CONTROLS:
TWO (2) SETS CONSTANT PRESSURE PUSH BUTTON
TYPE.
FIRST SET MOUNTED AT LOWER LEVEL WHICH
INCLUDES:
- HOIST: RAISE/LOWER
- RAMP/LOAD LIP: RAISE/LOWER
- E-STOP
2ND SET MOUNTED AT UPPER LEVEL WITH HOIST:
- RAISE/LOWER
COLOUR/FINISH: UNIT BLUE RAL 5010.
WALLS & GATES: YELLOW.
POWER PACK: 2.2 kW, 415 V AC, 3 PHASE, 50 hz, 5.6 AMP
FULL LOAD CURRENT, D.O.L MOTOR STARTER.
SIGNED AND DATED FINAL CONSTRUCTION
DRAWINGS MUST BE RECEIVED BY STS
BEFORE MANUFACTURE CAN BEGIN
FINAL CONSTRUCTION DRAWINGS
SIGNATURE:
DATE:
- These drawings contain all dimensions and information required for STS to
design and manufacture the equipment.
- You confirm these to be the CORRECT DIMENSIONS and FINAL DESIGN
- Change to any design or dimension subsequently required by any party
other than STS is a chargeable variation to the contract that you agree to pay
for.
- Delay in receipt of signed final drawings will affect equipment dispatch and
completion date.
APPROVED
COMPANY POSITION:
HOIST SPECIFICATIONS
BUILDER TO PROVIDE
DATE INIT. REVDESCRIPTION
35
COMPRESSED
PLATFORM HEIGHT
130
RAMP LENGTH
1757
O/A LENGTH (LOWER LEVEL DOOR CLOSED)
3269
O/A LENGTH (LOWER LEVEL DOOR OPEN)
2035
FREESTANDING
FRAME WIDTH
2107
O/A WIDTH
(INCL. POWER UNIT)
1716
UPPER LEVEL SWING GATE (OPEN)
85
UPPER LEVEL SWING GATE (CLOSED)
1050
SWING GATE
HEIGHT
1600
CLEAR PLATFORM LENGTH
1420
CLEAR
PLATFORM
WIDTH
2125
SWING DOOR
CLEAR OPENING HEIGHT
RAMP INTEGRATED IN FRAME
ON BOARD POWER UNIT
GPO BY BUILDER
GUARD LOCKED
SWING DOOR
AT LOWER LEVEL
GUARD LOCKED SWING GATE AT UPPER LEVEL
- MOUNTED TO FREESTANDING FRAME
1517
SWING DOOR CLEAR OPENING WIDTH
1526
SWING GATE
CLEAR OPENING
LOWER LEVEL CONTROLS
UPPER LEVEL CONTROLS
PRELIMINARY ONLY
FOR CUSTOMER CONCEPT APPROVAL
DO NOT CONSTRUCT FROM THIS DRAWING
DATE: SIGNATURE:
POWER REQUIREMENTS:
415V, 3 PHASE, 10AMP, 5 PIN SWITCHED OUTLET
(CLIPSAL 56C510 OR EQUIVALENT)
PROTECTED BY A D-CURVE CIRCUIT BRAKER.
GENERAL NOTES:
1) DRAINAGE BY BUILDER IF REQUIRED.
2) OUTLET MUST BE ENERGISED AND AVAILABLE
FOR USE BY US PRIOR TO HOIST INSTALL.
INCLUDES WIRING TO GPO AND
SUPPLY OF POWER AS SPECIFIED.
2900 / 3700 / 4500O/A HEIGHT
MATERIALS HANDLING P/L
1600 / 2400 / 3200MAXIMUM
TRAVEL
CONFIRM ALL DETAIL, SIGN AND DATE FOR APPROVAL PRIOR TO
MATERIALS HANDLING P/L COMPLETING DESIGN
MODELS: 1600 / 2400 / 3200CAPACITY: 1500 kg
LOWERED HEIGHT: 35 mm
TRAVEL: 1600 / 2400 / 3200 / 4000 mm
SPEED (NOMINAL): 2.0 m/minute
TRAVEL TIME: 48 / 72 seconds
PLATFORM LENGTH: 1600 mm
PLATFORM WIDTH: 1420 mm
FLOOR FINISH: CHEQUER PLATE
CONTROLS:
TWO (2) SETS CONSTANT PRESSURE PUSH
BUTTON TYPE FOR HOIST RAISE/LOWER
- FIRST SET MOUNTED AT LOWER LEVEL
- SECOND SET MOUNTED AT UPPER LEVEL
COLOUR/FINISH: UNIT BLUE RAL 5010.
WALLS & GATES: YELLOW.
FREESTANDING FRAME
- DOES NOT NEED TO BE FIXED TO DOCK FACE
UPPER LEVEL SWING GATE FIXED TO FREESTANDING FRAME
POWER UNIT: 2.2kW, 415/3/50, ONBOARD
LEFT HAND VERSION
RIGHT HAND VERSION
C:\P
ro
je
ct w
ork are
a\B
IN
LIF
T\B
IN
L
IF
T 2
.0.IN
VE
NT
OR
\~
BIN
-L
IF
T.G
A.idw
- S
he
et # 2
QUANTITY: FINISH:
NEW BIN LIFT DESIGN
TITLE:
GENERAL ARRANGEMENT
JOB NO.:
A1
SIZE:
hannos
DRAWN: DRG. NO.:CODE:
SCALE:
1 : 50
DATE:
7/09/2015
DXF FILE:
~BIN-LIFT.GA.idw
FILENAME:
ALL DIMENSIONS
IN mm UNLESS
STATED OTHERWISE
SERIAL NO.:
PRELIMINARY ONLY
FOR CUSTOMER CONCEPT APPROVAL
DO NOT CONSTRUCT FROM THIS DRAWING
DATE: SIGNATURE:
MATERIALS HANDLING P/L
CONFIRM ALL DETAIL, SIGN AND DATE FOR APPROVAL PRIOR TO
MATERIALS HANDLING P/L COMPLETING DESIGN