990 South Broadway #230 Denver, CO 80209 P 303.561.3333
1.24.2019 PAGE 1
FINAL DRAINAGE REPORT
WILLOW BEND HOLLY STREET SUPPLEMENTAL DRAINAGE REPORT TO
WILLOW BEND PHASE I DRAINAGE REPORT Thornton, CO
April 6, 2018
JN: DCS-17-4088
Prepared for:
Lennar
9781 S. Meridian Blvd., #120
Englewood, CO 80112
Prepared by:
Ware Malcomb Engineering and Surveying
990 S Broadway
Denver, CO 80209
P: 303.561.3333
F: 303.561.3339
Thomas C. Jansen, PE No. 35942
Principal
Willow Bend – Holly Street
04/06/2018
1.24.2019 PAGE 2 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
Lennar hereby certifies that the drainage facilities for the Holly Street will be constructed
according to the design presented in this report. I understand that the City of Thornton does
not and shall not assume liability for the drainage facilities designed and/or certified by my
engineer. I understand that the City of Thornton reviews drainage plans but cannot, on behalf
of Holly Street, guarantee that final drainage design review will absolve Lennar and/or their
successors and/or assigns of future liability for improper design. I further understand that
approval of the Plat and/or development permit does not imply approval of my engineer’s
drainage design.
Attest: __________________________________
Name of Responsible Party
_____________________________ _________________________________
Notary Public Authorized Signature
CERTIFICATION
I hereby certify that this report (plan) for the final drainage design of Holly Street was
prepared by me (or under my direct supervision) in accordance with the provisions of the City
of Thornton Standards and Specifications for the Design and Construction of Public and
Private Improvements for the Responsible parties thereof. I understand that the City of
Thornton does not and shall not assume liability for drainage facilities designed by others.
Thomas C. Jansen, PE Date
State of Colorado Registration No. 35942
For and on behalf of Ware Malcomb Engineering and Surveying
Willow Bend – Holly Street
04/06/2018
1.24.2019 PAGE 3 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
T A B L E O F C O N T E N T S
I. GENERAL LOCATION AND DESCRIPTION .............................................................................................. 5
II. DRAINAGE BASINS AND SUB-BASINS .................................................................................................... 6
III. DRAINAGE DESIGN AND CRITERIA ........................................................................................................ 6
IV. STORMWATER MANAGEMENT FACILITY DESIGN ................................................................................. 8
V. CONCLUSION....................................................................................................................................... 13
VI. REFERENCES ........................................................................................................................................ 14
Willow Bend – Holly Street
04/06/2018
1.24.2019 PAGE 4 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
A P P E N D I C E S
APPENDIX A – Reference Materials
FEMA Flood Insurance Rate Map
NRCS Soil Information
Related Drainage Reports
Future Land Use Map
APPENDIX B – Site Hydrology and Hydraulics
% Impervious Calculations
“C” Value Calculations
Time of Concentration
SF2 & SF3 Rational Method Calculations
Inlet Calculations
Storm Sewer Design
APPENDIX C – Clogged Inlets and Street Capacity
Clogged Inlet Analysis
Street Section Capacity Checks
APPENDIX D - Maps
Developed Basin Map
Willow Bend – Holly Street
04/06/2018
1.24.2019 PAGE 5 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
I. GENERAL LOCATION AND DESCRIPTION
The purpose of this report is to define and analyze developed runoff quantities and
conveyance for the Willow Bend Holly Street improvements. Runoff will generally drain
toward the curb and gutter on the west side of Holly Street and enter the on-grade inlets.
The storm sewer will ultimately convey the runoff to the existing Full Spectrum EURV and
100-year detention pond, part of Willow Bend Phase 1, prior to being discharged into
Todd Creek below Holly Street. A section of Holly Street will enter a sump inlet and be
conveyed directly into the pond outfall pipe as outlined in the Willow Bend Phase I
Drainage Report.
A. Site Location
The Willow Bend Holly Street improvements are located along the eastern border of the
Willow Bend Subdivision which is in the east ½ of Section 18, Township 1 South, Range 67
West of the Sixth Principal Meridian, County of Adams, Colorado. Holly Street is bounded
by adjacent developments which include Willow Bend Phase I and Phase II. The developed
portion of Holly Street lies north of E 144th Avenue and south of E-470. See the enclosed
vicinity map and the Final Drainage Map in Appendix D for exact locations.
B. Description of Property
The entire Willow Bend Holly Street improvements are approximately 5.66 acres, which
includes paving, median installation, storm sewer, curb and gutter, sanitary line
realignment, signage and striping.
The existing road is an asphalt and dirt road with faint striping that has no curb and gutter.
The USCS Soils Survey indicates that the site is underlain by Platner loam (PIB and PIC)
hydrological groups C and D, as well as Ulm loam (UIC and UID) hydrologic soil groups C
and D. See the soil map located in Appendix A. Platner and Ulm soils are described as
having slow permeability on nearly level to mildly sloping areas. Land cover currently
consists of agricultural row crops.
Hydrologic soil group C soils are identified as soils having a slow infiltration rate when
thoroughly wetted and consisting chiefly of soils with a layer that impedes downward
movement of water or soils with moderately-fine to fine texture. Hydrologic soil group D
soils are identified as soils having high runoff potential when thoroughly wet. Water
movement through Type D soils is restricted to very restricted.
Willow Bend – Holly Street
04/06/2018
1.24.2019 PAGE 6 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
II. DRAINAGE BASINS AND SUB-BASINS
A. Major Drainage Basins
This site lies within the Todd Creek major drainage basin.
In the developed condition, the actual imperviousness is 100% for the paved areas per
Urban Drainage Criteria. According to the Thornton Future Land Use Map (Appendix A),
the vacant property to the east of the proposed roadway is zoned for Low Density
Residential, while the property to the west is zoned for Medium and High Density
Residential.
As previously mentioned, there is a FEMA Zone A Floodplain on the site. According to the
Flood Insurance Rate Map Number 08001C0308H (03/05/2007), Holly Street is mostly
within Zone X, with a portion of the site identified as being within Zone A running north
to south towards the eastern portion of the site. Refer to Appendix A for the Flood
Insurance Rate Map information. The Zone A floodplain shown in the map has been
conditionally approved to be amended by a CLOMR recorded on January 1, 2004.
B. Sub-Basin Description
The entire site lies within the Todd Creek major drainage basin and historically drains
towards the existing undefined drainageway running through the Willow Bend
Subdivision to the west and connects into Todd Creek. The basins of Willow Bend Holly
Street have been evaluated in this report as “Basin A”. Ultimately all flows within Basin A
will be conveyed to the existing detention and WQCV pond either by way of curb and
gutter and storm sewer. Holly Street was analyzed with the preparation of the Willow
Bend Phase I drainage report in order to properly size the proposed detention and water
quality pond as well as sizing the Todd Creek channel and identifying storm sewer outfall
locations. The Holly Street drainage design will work to fit within the framework for the
existing pond and Todd Creek channel presented within Willow Bend Phase I Drainage
Report.
III. DRAINAGE DESIGN AND CRITERIA
A. Regulations
The regulations, guidelines, and drainage design criteria used for this report are those
contained within the City of Thornton Standards and Specifications for the Design and
Construction of Public Improvements, October 2012 and the Urban Drainage Criteria
Manual, Volume 1, 2, and 3, 2017 edition. The UDFCD USDCM (Volume 1, March 2017)
Table 6-3 has been used for impervious values for all runoff conveyance and BMP sizing.
Similarly, riprap has been designed in accordance with UDFCD criteria in lieu of City of
Willow Bend – Holly Street
04/06/2018
1.24.2019 PAGE 7 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
Thornton criteria that requires grouted riprap. Onsite inlets have been sized and designed
utilizing both UDFCD and City of Thornton Criteria, with street capacities and storm sewer
being designed in accordance with UDFCD criteria and supplemental requirements
contained within the City of Thornton Criteria.
B. Drainage Studies, Outfall Systems Plans, Site Constraints
There are no irregular site constraints that come by way of any streets, utilities, structures
or other potential conflicts to the overall drainage design.
C. Hydrology
For the purpose of this report, the onsite flows routed to the storm sewer were calculated
using rational method calculations. These calculations have been included in Appendix B.
The minor and major storm frequencies for design are the 5-year and 100-year storm
events, respectively. The one hour point rainfall for the 5-year event is 1.38 inches and
2.69 inches for the 100-year event. For consistency, the same one hour point rainfall data
was used on this design as was used on Willow Bend Phase 1. These values have been
taken directly from the City of Thornton Standards and Specifications (Revised October
2012).
The peak discharge for sizing the onsite storm sewer and for the street capacity
calculations was calculated using the following Rational Method formula:
Q=CIA
Where:
Q = peak discharge (cfs)
C = runoff coefficient from Table 6-4 of the UDSCM
I = rainfall intensity (inches/hour)
A = drainage area (acres)
These flows were routed through the site using the UDFCD SF-3 form to determine the
total flow at respective design points. See Appendix B for routing spreadsheets.
The water quality and detention pond is located in the northwest corner of Holly Street
and Signal Ditch Parkway and has been sized for all three phases of Willow Bend, including
Holly Street. The pond was designed using Hydrographs provided from Urban Drainage
for full spectrum detention and in accordance with Urban Drainage and City of Thornton
criteria. Storage for the 100-year detention volume is provided within this pond.
Willow Bend – Holly Street
04/06/2018
1.24.2019 PAGE 8 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
D. Hydraulics
Allowable street capacities for the proposed improvements are in accordance with
UDFCD and the City of Thornton Standards. In the minor storm event, runoff in the streets
is not allowed to overtop the crown and is not allowed to over top the curb. In the major
storm event runoff cannot flow at a depth greater than 12 inches or extend beyond the
right-of-way. Flows will not encroach upon residential lots in accordance with City of
Thornton Criteria. Street capacity was checked for Holly Street. The Flowmaster output is
included in Appendix C.
Inlets have been designed throughout the site to capture runoff from Holly Street before
maximum allowable street capacities are exceeded and at the sump location. Inlet
calculations have been prepared for the site using the Urban Drainage and Flood Control
District UD-Inlet_V4.05.xls spreadsheet. Inlet capture calculations are provided in
Appendix B. All inlets have also been analyzed to ensure there is an emergency overflow
route which keeps runoff away from residential lots. All Type R inlets will have a 6-inch
throat height as shown on the CDOT M Standard drawings.
Proposed storm sewers have been designed in accordance with the City of Thornton
Standards. During the minor storm event, flows within the storm sewer remain within
the pipe, that is, the storm sewer system does not become pressurized. City of Thornton
criteria allows the 100-year storm to be conveyed in the overall drainage system, which
can include the street as well as the proposed storm sewer provided street capacities are
not exceeded with the additional flows. Bentley StormCAD CONNECT software was
utilized to perform hydraulic computations on the proposed storm sewer, including the
calculation of hydraulic grade lines. StormCAD output for the proposed storm sewer,
including profiles with hydraulic grade lines, is included in Appendix B. In the design of
Phase II, the system is not surcharged in the major storm event.
Riprap for all pipe outlet locations has been sized and designed in accordance with UDFCD
USDCM Volume 2, Section 3.4 criteria.
IV. STORMWATER MANAGEMENT FACILITY DESIGN
A. General Concept
Stormwater within the developed street will be conveyed within the street section to
proposed storm sewer inlets. Runoff captured in proposed inlets will be conveyed
through proposed storm sewer to the existing regional pond. Runoff rates will be
attenuated to allowable release rates based of UDFCD criteria and existing downstream
offsite conditions for full spectrum detention and released offsite back into the Todd
Creek drainageway.
Willow Bend – Holly Street
04/06/2018
1.24.2019 PAGE 9 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
B. Sub-Basin Descriptions
Basin A:
Willow Bend Holly Street Basin A development consists of the redevelopment of Holly
Street. Proposed drainage basins for the site will generally follow historic patterns.
Basin A-1 (1.98 acres)
Basin A-1 accounts for 1.98 acres of proposed roadway and adjacent sidewalk that is
tributary to an on-grade 15’ Type R inlet located at DP 1 within Holly Street. This basin lies
on the southern portion of the proposed roadway. A 15’ Type R inlet has been designed
to capture runoff from Basin A-1 during the major storm event. Captured runoff at DP 1
will be conveyed to the existing regional pond via proposed storm sewer and
drainageway. Peak runoff rates are anticipated to be 6.4 cfs and 14.6 cfs in the minor and
major storm events, respectively. Should the inlet need to overflow, flow will continue
north to DP2.
Basin A-1 Data
5 Year = 6.4 cfs C5 = 0.79
100 Year = 14.6 cfs C100 = 0.86
Basin A-2 (0.22 acres)
Basin A-2 accounts for 0.22 acres of proposed roadway and adjacent sidewalk that is
tributary to an on-grade 10’ Type R inlet located at DP2 within Holly Street. This basin lies
on the southern portion of the proposed roadway, just north of Basin A-1. Runoff from
this basin, upon entering into the proposed inlet, will be conveyed by storm sewer to the
existing regional detention pond. Runoff rates are anticipated to be 0.7 cfs and 1.6 cfs in
the minor and major storm events, respectively. This inlet also takes carryover flow from
Basin A-1.
Basin A-2 Data
5 Year = 0.7 cfs C5 = 0.72
100 Year = 1.6 cfs C100 = 0.83
Basin A-3 (0.22 acres)
Basin A-3 accounts for 0.22 acres of proposed roadway and adjacent sidewalk that is
tributary to an on-grade 10’ Type R inlet located at DP3 within Holly Street. This basin lies
along the proposed roadway, just north of Basin A-2 and south of the intersection
between Holly Street and Hudson Way. Runoff from this basin, upon entering into the
proposed inlet, will be conveyed by storm sewer to the existing regional detention pond.
Runoff rates are anticipated to be 0.6 cfs and 1.5 cfs in the minor and major storm events,
respectively.
Willow Bend – Holly Street
04/06/2018
1.24.2019 PAGE 10 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
Basin A-3 Data
5 Year = 0.6 cfs C5 = 0.72
100 Year = 1.5 cfs C100 = 0.83
Basin A-4 (1.38 acres)
Basin A-4 accounts for 1.38 acres of proposed roadway and adjacent sidewalk that is
tributary to an on-grade 15’ Type R inlet located at DP4 within Holly Street. This basin lies
along the proposed roadway, just north of Basin A-3 and south of Basin A-5. Runoff from
this basin, upon entering into the proposed inlet, will be conveyed by storm sewer to the
existing regional detention pond. Runoff rates are anticipated to be 3.9 cfs and 9.3 cfs in
the minor and major storm events, respectively.
Basin A-4 Data
5 Year = 3.9 cfs C5 = 0.77
100 Year = 9.3 cfs C100 = 0.85
Basin A-5 (1.04 acres)
Basin A-5 accounts for 1.04 acres of proposed roadway and adjacent sidewalk that is
tributary to an on-grade 10’ Type R inlet located at DP5 within Holly Street. This basin lies
along the proposed roadway, just north of Basin A-4 and south of Basin A-6. Runoff from
this basin, upon entering into the proposed inlet, will be conveyed by storm sewer to the
existing regional detention pond. Runoff rates are anticipated to be 2.1 cfs and 5.6 cfs in
the minor and major storm events, respectively.
Basin A-5 Data
5 Year = 2.1 cfs C5 = 0.72
100 Year = 5.6 cfs C100 = 0.82
Basin A-6 (1.02 acres)
Basin A-6 accounts for 0.52 acres of proposed roadway and adjacent sidewalk that is
tributary to an on-grade 15’ Type R inlet located at DP6 within Holly Street. This basin lies
along the proposed roadway, just north of Basin A-5 and south of the intersection
between Holly Street and Signal Ditch Parkway. Runoff from this basin, upon entering into
the proposed inlet, will be conveyed by storm sewer to the existing regional detention
pond. Runoff rates are anticipated to be 1.7 cfs and 3.8 cfs in the minor and major storm
events, respectively.
Basin A-6 Data
5 Year = 2.1 cfs C5 = 0.72
100 Year = 5.7 cfs C100 = 0.83
Willow Bend – Holly Street
04/06/2018
1.24.2019 PAGE 11 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
Basin A-7 (1.27 acres)
Basin A-7 accounts for 1.27 acres of proposed roadway and adjacent sidewalk that is
tributary to a sump inlet located at DP7 within Holly Street. This basin lies along the
proposed roadway, just north of Basin A-6 and south of the intersection between Holly
Street and E-470. Runoff from within this basin, is tributary to the 15’ Type R sump inlet
at DP7. Runoff from this basin, upon entering into the proposed inlet, will be conveyed
by storm sewer south and ultimately enter into the proposed pond at DP9. Runoff rates
are anticipated to be 4.5 cfs and 9.6 cfs in the minor and major storm events, respectively.
Basin A-7 Data
5 Year = 4.5 cfs C5 = 0.77
100 Year = 9.6 cfs C100 = 0.85
Basin A-8 (0.92 acres)
Basin A-8 accounts for 0.92 acres of proposed roadway and adjacent sidewalk that is
tributary to a sump inlet located at DP8 within Signal Ditch Parkway. This basin lies along
the southern half of Signal Ditch Parkway, west of Basin A-7 and south of the regional
pond. Runoff from within this basin, is tributary to the 10’ Type R sump inlet at DP8.
Runoff from this basin, upon entering into the proposed inlet, will be conveyed north by
storm sewer and ultimately enter into the proposed pond at DP9. Runoff rates are
anticipated to be 2.0 cfs and 5.1 cfs in the minor and major storm events, respectively.
Basin A-8 Data
5 Year = 2.0 cfs C5 = 0.76
100 Year = 5.1 cfs C100 = 0.84
Basin A-9 (0.33 acres)
Basin A-9 accounts for 0.33 acres of proposed roadway and adjacent sidewalk that is
tributary to a sump inlet located at DP9 within Signal Ditch Parkway. This basin lies along
the northern half of Signal Ditch Parkway, west of Basin A-7 and south of the regional
pond. Runoff from within this basin, is tributary to the 10’ Type R sump inlet at DP9.
Runoff from this basin, upon entering into the proposed inlet, will be conveyed north by
storm sewer and enter into the proposed pond at DP9. Runoff rates are anticipated to be
1.1 cfs and 2.4 cfs in the minor and major storm events, respectively.
Basin A-9 Data
5 Year = 1.1 cfs C5 = 0.73
100 Year = 2.4 cfs C100 = 0.83
Willow Bend – Holly Street
04/06/2018
1.24.2019 PAGE 12 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
SUMP AND EMERGENCY OVERFLOWS:
Clogged Inlet Scenario Check
A scenario has been analyzed in order to route flow in the case that the inlet at the sump
location is clogged. Appendix C provides plan sheets, overflow sections and UD inlet
calculations that were used to route the flows from the clogged inlet through the site, as
well as associated street capacity checks. For all clogged inlet scenarios analyzed,
overflow will either enter directly into the regional pond or into the channel that carries
flow into the pond. The channel and pond have both been sized adequately to accept any
additional flow from these inlets and those calculations can be seen as a part of the
Willowbend Phase I drainage report.
The following summaries detail a scenario when the named design points have been
clogged and a description of the resulting action of the flow during these clogged
instances. Please note, the following descriptions only summarize sump inlets, but include
all the flows that would be conveyed to those areas. In instances where the downstream
section is a street, the additional flow that would already be going to the next
downstream inlets is included in the analysis.
DP7
In the case that this 10-foot Type R sump inlet were clogged a total flow during a 100-year
storm would be 9.6 cfs. Per the Flowmaster analysis provided the ponding elevation
would be at an elevation of 5202.25. At this elevation, the ponding would not affect any
nearby property and would overtop the back of curb at DP7 where it enters directly into
the existing regional pond constructed with Willowbend Phase I. Due to the fact that the
regional pond was designed to capture this flow no downstream profile has been
provided for potential impact on the system downstream.
DP8
In the case that this 10-foot Type R sump inlet were clogged a total flow during a 100-year
storm would be 5.1 cfs. Per the Flowmaster analysis provided the ponding elevation
would be at an elevation of 5206.14. At this elevation, the ponding would not affect any
nearby property and would overtop the back of curb at DP8 where it enters directly into
the existing Todd Creek drainage channel. Due to the fact that the drainage channel was
designed to capture this flow no downstream profile has been provided for potential
impact on the system downstream.
DP9
In the case that this 10-foot Type R sump inlet were clogged a total flow during a 100-year
storm would be 2.4 cfs. Per the Flowmaster analysis provided the ponding elevation
would be at an elevation of 5206.15. At this elevation, the ponding would not affect any
nearby property and would overtop the back of curb at DP9 where it enters directly into
Willow Bend – Holly Street
04/06/2018
1.24.2019 PAGE 13 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
the existing regional pond constructed with Willowbend Phase I. Due to the fact that the
regional pond was designed to capture this flow no downstream profile has been
provided for potential impact on the system downstream.
C. Full Spectrum Detention
Runoff from the site will be conveyed by way of storm sewer inlets and pipe running north
up Holly Street. The flows conveyed from the proposed Willow Bend Holly Street
development will be discharged to the regional detention pond located at the intersection
of Todd Creek and Holly Street. The proposed detention pond was sized based on the
Todd Creek OSP that includes Willow Bend Phases 1, 2 and 3 (including the school and
park), offsite Willow Bend multifamily, portions of Lewis Pointe, and the offsite properties
to the west and Holly Street. Due to invert of the pipe at DP9 coming into the pond being
below the tailwater elevation, the pipes are designed to have the water be stored partially
in the pipes for the 5-year and 100-year storm. Water will pond at the sump inlet at DP7
during the 100-year storm, but will not encroach the right-of-way.
V. CONCLUSION
This drainage report has been prepared in conformity, except where otherwise allowed
by variance, with the City of Thornton 2012 Standards and Specifications for the Design
and Construction of Public and Improvements, and Urban Drainage Criteria Manuals, the
2017 edition. The proposed drainage plan is also in conformance with assumptions made
within the OSP and MDP studies that were prepared for the Todd Creek major drainage
basin. The proposed drainage facilities shall safely and effectively convey significant storm
events to adequate outfall locations.
Willow Bend – Holly Street
04/06/2018
1.24.2019 PAGE 14 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
VI. REFERENCES
1. Urban Storm Drainage Criteria Manual, Volumes 1, 2, and 3, Urban Drainage and Flood
Control District, June 2001, with updates to September 2017.
2. Natural Resources Conservation Center Web Soil Survey, United States Department of
Agriculture, site visited January 2012.
3. Federal Emergency Management Agency Flood Insurance Rate Map, Community-Panel
Number 08001C0308H, Revised March 5, 2007.
4. City of Thornton – Standards and Specifications, City of Thornton, CO, Revised February
2012.
5. Todd Creek and DFA 0052 Watersheds Outfall Systems Planning Study, City of Thornton,
Adams County and UDFCD, December 2003.
6. Willow Bend Drainage Report, Released 11/19/2018
7. UD-Inlet_V4.01 (May 2016)
8. Bentley StormCAD CONNECT Edition Update 1 (5/1/2018)
9. Bentley FlowMaster V8i (SELECTseries 1) (11/4/2009)
Willow Bend – Holly Street
04/06/2018
1.24.2019 PAGE 15 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
APPENDIX A – Reference Materials
FEMA Flood Insurance Rate Map
NRCS Soil Information
Related Drainage Reports
Future Land Use Map
Soil Map—Adams County Area, Parts of Adams and Denver Counties, Colorado(Willowbend)
Natural ResourcesConservation Service
Web Soil SurveyNational Cooperative Soil Survey
12/16/2014Page 1 of 3
4423
000
4423
100
4423
200
4423
300
4423
400
4423
500
4423
600
4423
700
4423
800
4423
900
4424
000
4424
100
4424
200
4424
300
4423
000
4423
100
4423
200
4423
300
4423
400
4423
500
4423
600
4423
700
4423
800
4423
900
4424
000
4424
100
4424
200
4424
300
505800 505900 506000 506100 506200 506300 506400 506500 506600 506700 506800
505800 505900 506000 506100 506200 506300 506400 506500 506600 506700 506800
39° 58' 10'' N10
4° 5
5' 5
9'' W
39° 58' 10'' N
104°
55'
12'
' W
39° 57' 22'' N
104°
55'
59'
' W
39° 57' 22'' N
104°
55'
12'
' W
N
Map projection: Web Mercator Corner coordinates: WGS84 Edge tics: UTM Zone 13N WGS840 300 600 1200 1800
Feet0 100 200 400 600
MetersMap Scale: 1:7,170 if printed on A portrait (8.5" x 11") sheet.
MAP LEGEND MAP INFORMATION
Area of Interest (AOI)Area of Interest (AOI)
SoilsSoil Map Unit Polygons
Soil Map Unit Lines
Soil Map Unit Points
Special Point FeaturesBlowout
Borrow Pit
Clay Spot
Closed Depression
Gravel Pit
Gravelly Spot
Landfill
Lava Flow
Marsh or swamp
Mine or Quarry
Miscellaneous Water
Perennial Water
Rock Outcrop
Saline Spot
Sandy Spot
Severely Eroded Spot
Sinkhole
Slide or Slip
Sodic Spot
Spoil Area
Stony Spot
Very Stony Spot
Wet Spot
Other
Special Line Features
Water FeaturesStreams and Canals
TransportationRails
Interstate Highways
US Routes
Major Roads
Local Roads
BackgroundAerial Photography
The soil surveys that comprise your AOI were mapped at 1:20,000.
Warning: Soil Map may not be valid at this scale.
Enlargement of maps beyond the scale of mapping can causemisunderstanding of the detail of mapping and accuracy of soil lineplacement. The maps do not show the small areas of contrastingsoils that could have been shown at a more detailed scale.
Please rely on the bar scale on each map sheet for mapmeasurements.
Source of Map: Natural Resources Conservation ServiceWeb Soil Survey URL: http://websoilsurvey.nrcs.usda.govCoordinate System: Web Mercator (EPSG:3857)
Maps from the Web Soil Survey are based on the Web Mercatorprojection, which preserves direction and shape but distortsdistance and area. A projection that preserves area, such as theAlbers equal-area conic projection, should be used if more accuratecalculations of distance or area are required.
This product is generated from the USDA-NRCS certified data as ofthe version date(s) listed below.
Soil Survey Area: Adams County Area, Parts of Adams andDenver Counties, ColoradoSurvey Area Data: Version 11, Sep 23, 2014
Soil map units are labeled (as space allows) for map scales 1:50,000or larger.
Date(s) aerial images were photographed: Apr 22, 2011—Apr 13,2012
The orthophoto or other base map on which the soil lines werecompiled and digitized probably differs from the backgroundimagery displayed on these maps. As a result, some minor shiftingof map unit boundaries may be evident.
Soil Map—Adams County Area, Parts of Adams and Denver Counties, Colorado(Willowbend)
Natural ResourcesConservation Service
Web Soil SurveyNational Cooperative Soil Survey
12/16/2014Page 2 of 3
Map Unit Legend
Adams County Area, Parts of Adams and Denver Counties, Colorado (CO001)
Map Unit Symbol Map Unit Name Acres in AOI Percent of AOI
PlB Platner loam, 0 to 3 percentslopes
74.0 32.7%
PlC Platner loam, 3 to 5 percentslopes
71.2 31.5%
UlC Ulm loam, 3 to 5 percent slopes 3.4 1.5%
UlD Ulm loam, 5 to 9 percent slopes 74.6 33.0%
W Water 3.0 1.3%
Totals for Area of Interest 226.3 100.0%
Soil Map—Adams County Area, Parts of Adams and Denver Counties, Colorado Willowbend
Natural ResourcesConservation Service
Web Soil SurveyNational Cooperative Soil Survey
12/16/2014Page 3 of 3
1.24.2019 PAGE 16 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
APPENDIX B – Site Hydrology and Hydraulics
% Impervious Calculations
“C” Value Calculations
Time of Concentration
SF2 & SF3 Rational Method Calculations
Inlet Calculations
Storm Sewer Design
= FORMULA CELLS
= USER INPUT CELLS
PROJECT:
JOB NO.:CALC. BY: �
DATE:
� �
Minutes
5
10
20
30
40
50
60
120
Equation 5-1 I=(28.5*P1)/(10+Td)^0.786
I = rainfall intensity (inches per hour)
P1 = 1-hour point rainfall depth (inches)
Td = storm duration (minutes)
Reference:
1) Urban Drainage and Flood Control District - Urban Storm Drainage Criteria Manual Volume 1, 2017
2) NOAA Atlas 14, Volume 8, Version 2
http://hdsc.nws.noaa.gov/hdsc/pfds/pfds_map_cont.html?bkmrk=co
1.38 2.69
9.12
7.28
5.29
4.22
3.54
3.07
4.68
3.73
2.71
2.17
1.82
1.57
1.39
Thornton - Civic Center
Project Location
P1: 1-hour Rainfall Depths (inches)
Willow Bend - Holly Street
17-4088LMO
4/6/2018
IDF Rainfall Data
5-Year
Minor Storm Major StormTd 100-Year
1.670.86
2.72
PROJECT:
JOB NO.:
CALC. BY:
DATE:
Impervious Percentages - from Urban Drainage Table 6-3
Paved 100% 0%
Drives and Walks 90% 0%
Lawns & Landscaping 10% 0%
Residetnial 45% 0%
SOIL TYPE: C or D � (use equation from Table 6-4) = FORMULA CELLS
= USER INPUT CELLS
Basin Area (ac) Imp. C2 C5 C10 C100 PavedDrives and
Walks
Lawns &
LandscapingResidetnial Land Use 5 Land Use 6 Land Use 7 Land Use 8
A-1 1.98 81% 0.66 0.70 0.73 0.82 1.28 0.32 0.38
A-2 0.22 73% 0.58 0.63 0.67 0.78 0.12 0.04 0.06
A-3 0.22 73% 0.58 0.63 0.67 0.78 0.12 0.03 0.06
A-4 1.38 75% 0.60 0.65 0.69 0.79 0.67 0.30 0.26 0.15
A-5 1.04 60% 0.47 0.53 0.58 0.73 0.27 0.16 0.17 0.45
A-6 1.02 61% 0.48 0.53 0.58 0.73 0.28 0.15 0.17 0.41
A-7 1.27 91% 0.75 0.78 0.81 0.86 0.92 0.25 0.09
A-8 0.92 69% 0.55 0.60 0.64 0.77 0.39 0.12 0.13 0.27
A-9 0.33 84% 0.68 0.72 0.75 0.83 0.18 0.10 0.05
Weighted Impervious and C Values Areas (ac)
Land Use 5
Land Use 6
Land Use 7
Land Use 8
PROPOSED COMPOSITE IMPERVIOUSNESS
Willow Bend - Holly Street
17-4088
LMO
4/6/2018
JANSEN STRAWN COMPOSITE C VALUES - PROP1/24/2019
17-4088-SF2 SF3 - Holly St.xlsx
Project: Willow Bend - Holly Street
Job No.: 17-4088
Calculated By: Checked By: TG
Date: 4/6/2018
FINAL REMARKS
tc
Basin i C5 AREA LENGTH SLOPE ti LENGTH SLOPE VEL. tt COMP. TOT. LENGTH So
Ac Ft % Min Ft % FPS Min tc Ft % Min Min
(1) (2) (3) (4) (5) (6) (7) (8) (9) (11) (12) (13) (14) (15) (16)
A-1 0.81 0.70 1.98 96 2.7 5.09 1,048 20 3.6 3.79 0.09 5.2 116 2.86 12.8 5.18
A-2 0.73 0.63 0.22 37 3.0 3.56 87 20 2.5 3.16 0.11 3.7 57 2.82 13.9 5.00
A-3 0.73 0.63 0.22 37 3.1 3.54 87 20 2.5 3.2 0.5 4.0 124 2.68 14.3 5.0
A-4 0.75 0.65 1.38 37 5.9 2.75 578 20 1.8 2.7 3.6 6.3 615 2.05 16.9 6.3
A-5 0.60 0.53 1.04 105 2.7 7.59 273 20 1.0 2.0 2.3 9.9 378 1.47 18.7 9.9
A-6 0.61 0.53 1.02 103 3.1 7.14 283 20 1.9 2.8 1.7 8.8 386 2.22 18.1 8.8
A-7 0.91 0.78 1.27 51 5.9 2.27 338 20 0.7 1.7 3.4 5.6 389 1.38 13.0 5.6
A-8 0.69 0.60 0.92 154 4.4 6.83 480 20 1.3 2.3 3.5 10.3 634 2.05 18.2 10.3
A-9 0.84 0.72 0.33 19 2.0 2.36 408 20 0.8 1.8 3.8 6.2 427 0.85 15.5 6.2
Equation 6-3 ti=((0.395(1.1-C5)SQRT(L))/(So^0.33))
Equation 6-5 tc=(26-17i)+(Lt/(60(14i+9)SQRT(So))) = FORMULA CELLS
= USER INPUT CELLS
NRCS Conveyance Factor K Table - Cv Value
20Paved Areas and Shallow Paved Swales
Short Pasture and Lawns
Nearly Bare Ground
Grassed Waterway
7
10
15
Heavy Meadow 2.5
Tillage/Field 5
INITIAL/OVERLAND
TIME (ti)
LMO
DATA
SUB-BASIN
STANDARD FORM SF-2
tc (Equation 6-5)
TIME OF CONCENTRATION SUMMARY
tc CHECK
(URBANIZED BASINS)
TRAVEL TIME
(tt)
Cv
JANSEN STRAWN
TOC1/24/2019
17-4088-SF2 SF3 - Holly St.xlsx
Calculated By: Project: Willow Bend - Holly Street
Date: Job No.: 17-4088
Checked By: Design Storm: 5-Year
= FORMULA CELLS
= USER INPUT CELLS
DE
SIG
N
PO
INT
AR
EA
DE
SIG
N
AR
EA
(AC
)
RU
NO
FF
CO
EF
F
tc
(MIN
)
C *
A
(AC
)
I
(IN
/HR
)
Q
(CF
S)
t c
(MIN
)
S (
C *
A)
(CA
)
I
(IN
/HR
)
Q
(CF
S)
SL
OP
E
(%)
ST
RE
ET
FL
OW
DE
SIG
N
FL
OW
(C
FS
)
SL
OP
E
(%)
PIP
E
DIA
M.
(IN
.)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20) (21) (22)
A-1 1 1.98 0.70 5.2 1.39 4.64 6.4 Flow from Basin A-1 to DP1
A-2 2 0.22 0.63 5.0 0.14 4.68 0.7 Flow from Basin A-2 to DP2
A-3 3 0.22 0.63 5.0 0.14 4.68 0.6 Flow from Basin A-3 to DP3
A-4 4 1.38 0.65 6.3 0.90 4.38 3.9 Flow from Basin A-4 to DP4
A-5 5 1.04 0.53 9.9 0.55 3.75 2.1 Flow from Basin A-5 to DP5
A-6 6 1.02 0.53 8.8 0.54 3.91 2.1 Flow from Basin A-6 to DP6
A-7 7 1.27 0.78 5.6 0.99 4.53 4.5 Flow from Basin A-7 to DP7
A-8 8 0.92 0.60 10.3 0.55 3.68 2.0 Flow from Basin A-8 to DP8
A-9 9 0.33 0.72 6.2 0.24 4.41 1.1 Flow from Basin A-9 to DP9
STANDARD FORM SF-3LMO
4/6/2018
TG
5-Year
STORM DRAINAGE SYSTEM DESIGN
(RATIONAL METHOD PROCEDURE)1.38
1-hour rainfall=
VE
LO
CIT
Y
(FP
S)
t t
(MIN
)
REMARKSBASIN
DIRECT RUNOFF TOTAL RUNOFF STREET PIPE
LE
NG
TH
(FT
)
JANSEN STRAWN
Minor SF-31/24/2019
17-4088-SF2 SF3 - Holly St.xlsx
Calculated By: Project: Willow Bend - Holly Street
Date: Job No.: 17-4088
Checked By: Design Storm: 100-Year
= FORMULA CELLS
= USER INPUT CELLS
DE
SIG
N
PO
INT
AR
EA
DE
SIG
N
AR
EA
(AC
)
RU
NO
FF
CO
EF
F
tc
(MIN
)
C *
A
(AC
)
I
(IN
/HR
)
Q
(CF
S)
t c
(MIN
)
S (
C *
A)
(CA
)
I
(IN
/HR
)
Q
(CF
S)
SL
OP
E
(%)
ST
RE
ET
FL
OW
DE
SIG
N
FL
OW
(C
FS
)
SL
OP
E
(%)
PIP
E
DIA
M.
(IN
.)
(2) (3) (4) (5) (6) (7) (8) (9) (10) (11) (12) (13) (14) (15) (16) (17) (18) (19) (20) (21) (22)
A-1 1 1.98 0.82 5.2 1.62 9.04 14.6 Flow from Basin A-1 to DP1
A-2 2 0.22 0.78 5.0 0.17 9.12 1.6 Flow from Basin A-2 to DP2
A-3 3 0.22 0.78 5.0 0.17 9.12 1.5 Flow from Basin A-3 to DP3
A-4 4 1.38 0.79 6.3 1.09 8.53 9.3 Flow from Basin A-4 to DP4
A-5 5 1.04 0.73 9.9 0.76 7.32 5.6 Flow from Basin A-5 to DP5
A-6 6 1.02 0.73 8.8 0.74 7.62 5.7 Flow from Basin A-6 to DP6
A-7 7 1.27 0.86 5.6 1.09 8.83 9.6 Flow from Basin A-7 to DP7
A-8 8 0.92 0.77 10.3 0.70 7.18 5.1 Flow from Basin A-8 to DP8
A-9 9 0.33 0.83 6.2 0.27 8.60 2.4 Flow from Basin A-9 to DP9
REMARKS
4/6/2018
TG
2.69
STANDARD FORM SF-3
100-Year
1-hour rainfall=
LMO
STORM DRAINAGE SYSTEM DESIGN
(RATIONAL METHOD PROCEDURE)
DIRECT RUNOFF TOTAL RUNOFF STREET
BASIN
PIPE
LE
NG
TH
(FT
)
VE
LO
CIT
Y
(FP
S)
t t
(MIN
)JANSEN STRAWN
Major SF-31/24/2019
17-4088-SF2 SF3 - Holly St.xlsx
PROJECT:
JOB NO.:
CALC. BY:
DATE:
Q5 Q100 Q5 Q100
A-1 1 1.98 6.4 14.6
A-2 2 0.22 0.7 1.6
A-3 3 0.22 0.6 1.5
A-4 4 1.38 3.9 9.3
A-5 5 1.04 2.1 5.6
A-6 6 1.02 2.1 5.7
A-7 7 1.27 4.5 9.6
A-8 8 0.92 2.0 5.1
A-9 9 0.33 1.1 2.4
= FORMULA CELLS
= USER INPUT CELLS
BASIN LABEL AREALOCAL (CFS) ACCUMULATIVE (CFS)DESIGN
POINT
Willow Bend - Holly Street
17-4088
LMO
4/6/2018
RUNOFF SUMMARY
Version 4.05 Released March 2017
Worksheet Protected
INLET NAME DP1 DP2 DP3 DP4 DP5 DP6
URBAN URBAN URBAN URBAN URBAN URBAN
STREET STREET STREET STREET STREET STREET
On Grade On Grade On Grade On Grade On Grade On Grade
CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
USER-DEFINED INPUT
User-Defined Design Flows
6.4 0.7 0.6 3.9 2.1 2.1
14.6 1.6 1.5 9.3 5.6 5.7
No Bypass Flow Received DP1 DP2 No Bypass Flow Received DP4 DP5
0.0 0.0 0.0 0.0 0.0 0.0
0.0 2.8 0.1 0.0 0.5 0.8
Watershed Characteristics
Watershed Profile
Minor Storm Rainfall Input
Major Storm Rainfall Input
CALCULATED OUTPUT
6.4 0.7 0.6 3.9 2.1 2.1
14.6 4.4 1.6 9.3 6.1 6.5
0.0 0.0 0.0 0.0 0.0 0.0
2.8 0.1 0.0 0.5 0.8 0.0
Minor Storm (Calculated) Analysis of Flow Time
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
Major Storm (Calculated) Analysis of Flow Time
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
N/A N/A N/A N/A N/A N/A
Site Type (Urban or Rural)
Calculated Local Peak Flow, Qp
Overland Flow Velocity, Vi
Channel Flow Velocity, Vt
Overland Flow Time, Ti
Channel Travel Time, Tt
Calculated Time of Concentration, Tc
Regional Tc
Calculated Local Peak Flow, Qp
C
Recommended Tc
Tc selected by User
Design Rainfall Intensity, I
C5
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
C
C5
Overland Flow Velocity, Vi
Recommended Tc
Tc selected by User
Design Rainfall Intensity, I
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
Channel Flow Velocity, Vt
Overland Flow Time, Ti
Channel Travel Time, Tt
Calculated Time of Concentration, Tc
Regional Tc
Channel Slope (ft/ft)
Channel Length (ft)
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Overland Length (ft)
INLET MANAGEMENT
Inlet Application (Street or Area)
Hydraulic Condition
Minor QKnown (cfs)
Major QKnown (cfs)
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Overland Slope (ft/ft)
Inlet Type
Bypass (Carry-Over) Flow from Upstream
Version 4.05 Released March 2017
Worksheet Protected
INLET NAME
USER-DEFINED INPUT
User-Defined Design Flows
Watershed Characteristics
Watershed Profile
Minor Storm Rainfall Input
Major Storm Rainfall Input
CALCULATED OUTPUT
Minor Storm (Calculated) Analysis of Flow Time
Major Storm (Calculated) Analysis of Flow Time
Site Type (Urban or Rural)
Calculated Local Peak Flow, Qp
Overland Flow Velocity, Vi
Channel Flow Velocity, Vt
Overland Flow Time, Ti
Channel Travel Time, Tt
Calculated Time of Concentration, Tc
Regional Tc
Calculated Local Peak Flow, Qp
C
Recommended Tc
Tc selected by User
Design Rainfall Intensity, I
C5
Minor Total Design Peak Flow, Q (cfs)
Major Total Design Peak Flow, Q (cfs)
C
C5
Overland Flow Velocity, Vi
Recommended Tc
Tc selected by User
Design Rainfall Intensity, I
Minor Flow Bypassed Downstream, Qb (cfs)
Major Flow Bypassed Downstream, Qb (cfs)
Channel Flow Velocity, Vt
Overland Flow Time, Ti
Channel Travel Time, Tt
Calculated Time of Concentration, Tc
Regional Tc
Channel Slope (ft/ft)
Channel Length (ft)
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Design Storm Return Period, Tr (years)
One-Hour Precipitation, P1 (inches)
Overland Length (ft)
INLET MANAGEMENT
Inlet Application (Street or Area)
Hydraulic Condition
Minor QKnown (cfs)
Major QKnown (cfs)
Receive Bypass Flow from:
Minor Bypass Flow Received, Qb (cfs)
Major Bypass Flow Received, Qb (cfs)
Subcatchment Area (acres)
Percent Impervious
NRCS Soil Type
Overland Slope (ft/ft)
Inlet Type
Bypass (Carry-Over) Flow from Upstream
DP7 DP8 DP9 User-Defined
URBAN URBAN URBAN
STREET STREET STREET
In Sump In Sump In Sump
CDOT Type R Curb Opening CDOT Type R Curb Opening CDOT Type R Curb Opening
4.5 2.0 1.1
9.6 5.1 2.4
No Bypass Flow Received No Bypass Flow Received No Bypass Flow Received
0.0 0.0 0.0
0.0 0.0 0.0
4.5 2.0 1.1
9.6 5.1 2.4
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
N/A N/A N/A
Project:
Inlet ID:
Gutter Geometry (Enter data in the blue cells)
Maximum Allowable Width for Spread Behind Curb TBACK = 8.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb) SBACK = 0.020 ft/ft
Manning's Roughness Behind Curb (typically between 0.012 and 0.020) nBACK = 0.016
Height of Curb at Gutter Flow Line HCURB = 6.00 inches
Distance from Curb Face to Street Crown TCROWN = 40.0 ft
Gutter Width W = 2.00 ft
Street Transverse Slope SX = 0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft) SW = 0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO = 0.036 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020) nSTREET = 0.015
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX = 17.0 17.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX = 6.0 8.3 inches
Allow Flow Depth at Street Crown (leave blank for no) check = yes
Maximum Capacity for 1/2 Street based On Allowable Spread Minor Storm Major Storm
Water Depth without Gutter Depression (Eq. ST-2) y = 4.08 4.08 inches
Vertical Depth between Gutter Lip and Gutter Flowline (usually 2") dC = 2.0 2.0 inches
Gutter Depression (dC - (W * Sx * 12)) a = 1.51 1.51 inches
Water Depth at Gutter Flowline d = 5.59 5.59 inches
Allowable Spread for Discharge outside the Gutter Section W (T - W) TX = 15.0 15.0 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.350 0.350
Discharge outside the Gutter Section W, carried in Section TX QX = 14.3 14.3 cfs
Discharge within the Gutter Section W (QT - QX) QW = 7.7 7.7 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 0.0 cfs
Maximum Flow Based On Allowable Spread QT = 22.0 22.0 cfs
Flow Velocity within the Gutter Section V = 10.0 10.0 fps
V*d Product: Flow Velocity times Gutter Flowline Depth V*d = 4.7 4.7
Maximum Capacity for 1/2 Street based on Allowable Depth Minor Storm Major Storm
Theoretical Water Spread TTH = 18.7 28.3 ft
Theoretical Spread for Discharge outside the Gutter Section W (T - W) TX TH = 16.7 26.3 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.318 0.206
Theoretical Discharge outside the Gutter Section W, carried in Section TX TH QX TH = 19.0 63.7 cfs
Actual Discharge outside the Gutter Section W, (limited by distance TCROWN) QX = 19.0 63.7 cfs
Discharge within the Gutter Section W (Qd - QX) QW = 8.9 16.6 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 4.0 cfs
Total Discharge for Major & Minor Storm (Pre-Safety Factor) Q = 27.9 84.3 cfs
Average Flow Velocity Within the Gutter Section V = 10.6 13.6 fps
V*d Product: Flow Velocity Times Gutter Flowline Depth V*d = 5.3 9.4
Slope-Based Depth Safety Reduction Factor for Major & Minor (d > 6") Storm R = 0.64 0.52
Max Flow Based on Allowable Depth (Safety Factor Applied) Qd = 17.9 44.0 cfs
Resultant Flow Depth at Gutter Flowline (Safety Factor Applied) d = 5.27 6.87 inches
Resultant Flow Depth at Street Crown (Safety Factor Applied) dCROWN = 0.00 0.00 inches
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Spread Criterion Qallow = 17.9 22.0 cfs
Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
Version 4.05 Released March 2017
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
Willow Bend - Holly Street
DP1
17-4088-UD-Inlet_v4.05.xlsm, DP1 1/24/2019, 3:45 PM
Design Information (Input) MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a') aLOCAL = 3.0 3.0 inches
Total Number of Units in the Inlet (Grate or Curb Opening) No = 3 3
Length of a Single Unit Inlet (Grate or Curb Opening) Lo = 5.00 5.00 ft
Width of a Unit Grate (cannot be greater than W, Gutter Width) Wo = N/A N/A ft
Clogging Factor for a Single Unit Grate (typical min. value = 0.5) Cf-G = N/A N/A
Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1) Cf-C = 0.10 0.10
Street Hydraulics: OK - Q < Allowable Street Capacity' MINOR MAJOR
Design Discharge for Half of Street (from Sheet Inlet Management ) Qo = 6.4 14.6 cfs
Water Spread Width T = 10.1 14.4 ft
Water Depth at Flowline (outside of local depression) d = 3.9 5.0 inches
Water Depth at Street Crown (or at TMAX) dCROWN = 0.0 0.0 inches
Ratio of Gutter Flow to Design Flow Eo = 0.575 0.414
Discharge outside the Gutter Section W, carried in Section Tx Qx = 2.7 8.6 cfs
Discharge within the Gutter Section W Qw = 3.7 6.0 cfs
Discharge Behind the Curb Face QBACK = 0.0 0.0 cfs
Flow Area within the Gutter Section W AW = 0.49 0.66 sq ft
Velocity within the Gutter Section W VW = 7.5 9.1 fps
Water Depth for Design Condition dLOCAL = 6.9 8.0 inches
Grate Analysis (Calculated) MINOR MAJOR
Total Length of Inlet Grate Opening L = N/A N/A ft
Ratio of Grate Flow to Design Flow Eo-GRATE = N/A N/A
Under No-Clogging Condition MINOR MAJOR
Minimum Velocity Where Grate Splash-Over Begins Vo = N/A N/A fps
Interception Rate of Frontal Flow Rf = N/A N/A
Interception Rate of Side Flow Rx = N/A N/A
Interception Capacity Qi = N/A N/A cfs
Under Clogging Condition MINOR MAJOR
Clogging Coefficient for Multiple-unit Grate Inlet GrateCoef = N/A N/A
Clogging Factor for Multiple-unit Grate Inlet GrateClog = N/A N/A
Effective (unclogged) Length of Multiple-unit Grate Inlet Le = N/A N/A ft
Minimum Velocity Where Grate Splash-Over Begins Vo = N/A N/A fps
Interception Rate of Frontal Flow Rf = N/A N/A
Interception Rate of Side Flow Rx = N/A N/A
Actual Interception Capacity Qa = N/A N/A cfs
Carry-Over Flow = Qo-Qa (to be applied to curb opening or next d/s inlet) Qb = N/A N/A cfs
Curb or Slotted Inlet Opening Analysis (Calculated) MINOR MAJOR
Equivalent Slope Se (based on grate carry-over) Se = 0.128 0.098 ft/ft
Required Length LT to Have 100% Interception LT = 14.35 24.74 ft
Under No-Clogging Condition MINOR MAJOR
Effective Length of Curb Opening or Slotted Inlet (minimum of L, LT) L = 14.35 15.00 ft
Interception Capacity Qi = 6.4 11.9 cfs
Under Clogging Condition MINOR MAJOR
Clogging Coefficient CurbCoef = 1.31 1.31
Clogging Factor for Multiple-unit Curb Opening or Slotted Inlet CurbClog = 0.04 0.04
Effective (Unclogged) Length Le = 14.34 14.34 ft
Actual Interception Capacity Qa = 6.4 11.8 cfs
Carry-Over Flow = Qb(GRATE)-Qa Qb = 0.0 2.8 cfs
Summary MINOR MAJOR
Total Inlet Interception Capacity Q = 6.4 11.8 cfs
Total Inlet Carry-Over Flow (flow bypassing inlet) Qb = 0.0 2.8 cfs
Capture Percentage = Qa/Qo = C% = 100 81 %
INLET ON A CONTINUOUS GRADE
Version 4.05 Released March 2017
CDOT Type R Curb OpeningCDOT Type R Curb Opening
17-4088-UD-Inlet_v4.05.xlsm, DP1 1/24/2019, 3:45 PM
Project:
Inlet ID:
Gutter Geometry (Enter data in the blue cells)
Maximum Allowable Width for Spread Behind Curb TBACK = 8.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb) SBACK = 0.020 ft/ft
Manning's Roughness Behind Curb (typically between 0.012 and 0.020) nBACK = 0.016
Height of Curb at Gutter Flow Line HCURB = 6.00 inches
Distance from Curb Face to Street Crown TCROWN = 40.0 ft
Gutter Width W = 2.00 ft
Street Transverse Slope SX = 0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft) SW = 0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO = 0.025 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020) nSTREET = 0.015
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX = 17.0 17.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX = 6.0 8.3 inches
Allow Flow Depth at Street Crown (leave blank for no) check = yes
Maximum Capacity for 1/2 Street based On Allowable Spread Minor Storm Major Storm
Water Depth without Gutter Depression (Eq. ST-2) y = 4.08 4.08 inches
Vertical Depth between Gutter Lip and Gutter Flowline (usually 2") dC = 2.0 2.0 inches
Gutter Depression (dC - (W * Sx * 12)) a = 1.51 1.51 inches
Water Depth at Gutter Flowline d = 5.59 5.59 inches
Allowable Spread for Discharge outside the Gutter Section W (T - W) TX = 15.0 15.0 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.350 0.350
Discharge outside the Gutter Section W, carried in Section TX QX = 11.9 11.9 cfs
Discharge within the Gutter Section W (QT - QX) QW = 6.4 6.4 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 0.0 cfs
Maximum Flow Based On Allowable Spread QT = 18.3 18.3 cfs
Flow Velocity within the Gutter Section V = 8.4 8.4 fps
V*d Product: Flow Velocity times Gutter Flowline Depth V*d = 3.9 3.9
Maximum Capacity for 1/2 Street based on Allowable Depth Minor Storm Major Storm
Theoretical Water Spread TTH = 18.7 28.3 ft
Theoretical Spread for Discharge outside the Gutter Section W (T - W) TX TH = 16.7 26.3 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.318 0.206
Theoretical Discharge outside the Gutter Section W, carried in Section TX TH QX TH = 15.8 53.1 cfs
Actual Discharge outside the Gutter Section W, (limited by distance TCROWN) QX = 15.8 53.1 cfs
Discharge within the Gutter Section W (Qd - QX) QW = 7.4 13.8 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 3.4 cfs
Total Discharge for Major & Minor Storm (Pre-Safety Factor) Q = 23.2 70.3 cfs
Average Flow Velocity Within the Gutter Section V = 8.9 11.3 fps
V*d Product: Flow Velocity Times Gutter Flowline Depth V*d = 4.4 7.8
Slope-Based Depth Safety Reduction Factor for Major & Minor (d > 6") Storm R = 0.86 0.70
Max Flow Based on Allowable Depth (Safety Factor Applied) Qd = 20.0 49.0 cfs
Resultant Flow Depth at Gutter Flowline (Safety Factor Applied) d = 5.74 7.48 inches
Resultant Flow Depth at Street Crown (Safety Factor Applied) dCROWN = 0.00 0.00 inches
MINOR STORM Allowable Capacity is based on Spread Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Spread Criterion Qallow = 18.3 18.3 cfs
Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
Version 4.05 Released March 2017
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
Willow Bend - Holly Street
DP2
17-4088-UD-Inlet_v4.05.xlsm, DP2 1/24/2019, 3:45 PM
Design Information (Input) MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a') aLOCAL = 3.0 3.0 inches
Total Number of Units in the Inlet (Grate or Curb Opening) No = 2 2
Length of a Single Unit Inlet (Grate or Curb Opening) Lo = 5.00 5.00 ft
Width of a Unit Grate (cannot be greater than W, Gutter Width) Wo = N/A N/A ft
Clogging Factor for a Single Unit Grate (typical min. value = 0.5) Cf-G = N/A N/A
Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1) Cf-C = 0.10 0.10
Street Hydraulics: OK - Q < Allowable Street Capacity' MINOR MAJOR
Design Discharge for Half of Street (from Sheet Inlet Management ) Qo = 0.7 4.4 cfs
Water Spread Width T = 2.1 9.3 ft
Water Depth at Flowline (outside of local depression) d = 2.1 3.7 inches
Water Depth at Street Crown (or at TMAX) dCROWN = 0.0 0.0 inches
Ratio of Gutter Flow to Design Flow Eo = 0.000 0.618
Discharge outside the Gutter Section W, carried in Section Tx Qx = 0.0 1.7 cfs
Discharge within the Gutter Section W Qw = 0.0 2.7 cfs
Discharge Behind the Curb Face QBACK = 0.0 0.0 cfs
Flow Area within the Gutter Section W AW = 0.19 0.46 sq ft
Velocity within the Gutter Section W VW = 0.0 6.0 fps
Water Depth for Design Condition dLOCAL = 5.1 6.7 inches
Grate Analysis (Calculated) MINOR MAJOR
Total Length of Inlet Grate Opening L = N/A N/A ft
Ratio of Grate Flow to Design Flow Eo-GRATE = N/A N/A
Under No-Clogging Condition MINOR MAJOR
Minimum Velocity Where Grate Splash-Over Begins Vo = N/A N/A fps
Interception Rate of Frontal Flow Rf = N/A N/A
Interception Rate of Side Flow Rx = N/A N/A
Interception Capacity Qi = N/A N/A cfs
Under Clogging Condition MINOR MAJOR
Clogging Coefficient for Multiple-unit Grate Inlet GrateCoef = N/A N/A
Clogging Factor for Multiple-unit Grate Inlet GrateClog = N/A N/A
Effective (unclogged) Length of Multiple-unit Grate Inlet Le = N/A N/A ft
Minimum Velocity Where Grate Splash-Over Begins Vo = N/A N/A fps
Interception Rate of Frontal Flow Rf = N/A N/A
Interception Rate of Side Flow Rx = N/A N/A
Actual Interception Capacity Qa = N/A N/A cfs
Carry-Over Flow = Qo-Qa (to be applied to curb opening or next d/s inlet) Qb = N/A N/A cfs
Curb or Slotted Inlet Opening Analysis (Calculated) MINOR MAJOR
Equivalent Slope Se (based on grate carry-over) Se = 0.064 0.136 ft/ft
Required Length LT to Have 100% Interception LT = 6.23 11.34 ft
Under No-Clogging Condition MINOR MAJOR
Effective Length of Curb Opening or Slotted Inlet (minimum of L, LT) L = 6.23 10.00 ft
Interception Capacity Qi = 0.7 4.3 cfs
Under Clogging Condition MINOR MAJOR
Clogging Coefficient CurbCoef = 1.25 1.25
Clogging Factor for Multiple-unit Curb Opening or Slotted Inlet CurbClog = 0.06 0.06
Effective (Unclogged) Length Le = 9.37 9.37 ft
Actual Interception Capacity Qa = 0.7 4.3 cfs
Carry-Over Flow = Qb(GRATE)-Qa Qb = 0.0 0.1 cfs
Summary MINOR MAJOR
Total Inlet Interception Capacity Q = 0.7 4.3 cfs
Total Inlet Carry-Over Flow (flow bypassing inlet) Qb = 0.0 0.1 cfs
Capture Percentage = Qa/Qo = C% = 100 97 %
INLET ON A CONTINUOUS GRADE
Version 4.05 Released March 2017
CDOT Type R Curb OpeningCDOT Type R Curb Opening
17-4088-UD-Inlet_v4.05.xlsm, DP2 1/24/2019, 3:45 PM
Project:
Inlet ID:
Gutter Geometry (Enter data in the blue cells)
Maximum Allowable Width for Spread Behind Curb TBACK = 8.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb) SBACK = 0.020 ft/ft
Manning's Roughness Behind Curb (typically between 0.012 and 0.020) nBACK = 0.016
Height of Curb at Gutter Flow Line HCURB = 6.00 inches
Distance from Curb Face to Street Crown TCROWN = 40.0 ft
Gutter Width W = 2.00 ft
Street Transverse Slope SX = 0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft) SW = 0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO = 0.025 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020) nSTREET = 0.015
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX = 17.0 17.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX = 6.0 8.3 inches
Allow Flow Depth at Street Crown (leave blank for no) check = yes
Maximum Capacity for 1/2 Street based On Allowable Spread Minor Storm Major Storm
Water Depth without Gutter Depression (Eq. ST-2) y = 4.08 4.08 inches
Vertical Depth between Gutter Lip and Gutter Flowline (usually 2") dC = 2.0 2.0 inches
Gutter Depression (dC - (W * Sx * 12)) a = 1.51 1.51 inches
Water Depth at Gutter Flowline d = 5.59 5.59 inches
Allowable Spread for Discharge outside the Gutter Section W (T - W) TX = 15.0 15.0 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.350 0.350
Discharge outside the Gutter Section W, carried in Section TX QX = 11.9 11.9 cfs
Discharge within the Gutter Section W (QT - QX) QW = 6.4 6.4 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 0.0 cfs
Maximum Flow Based On Allowable Spread QT = 18.3 18.3 cfs
Flow Velocity within the Gutter Section V = 8.4 8.4 fps
V*d Product: Flow Velocity times Gutter Flowline Depth V*d = 3.9 3.9
Maximum Capacity for 1/2 Street based on Allowable Depth Minor Storm Major Storm
Theoretical Water Spread TTH = 18.7 28.3 ft
Theoretical Spread for Discharge outside the Gutter Section W (T - W) TX TH = 16.7 26.3 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.318 0.206
Theoretical Discharge outside the Gutter Section W, carried in Section TX TH QX TH = 15.8 53.1 cfs
Actual Discharge outside the Gutter Section W, (limited by distance TCROWN) QX = 15.8 53.1 cfs
Discharge within the Gutter Section W (Qd - QX) QW = 7.4 13.8 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 3.4 cfs
Total Discharge for Major & Minor Storm (Pre-Safety Factor) Q = 23.2 70.3 cfs
Average Flow Velocity Within the Gutter Section V = 8.9 11.3 fps
V*d Product: Flow Velocity Times Gutter Flowline Depth V*d = 4.4 7.8
Slope-Based Depth Safety Reduction Factor for Major & Minor (d > 6") Storm R = 0.86 0.70
Max Flow Based on Allowable Depth (Safety Factor Applied) Qd = 20.0 49.0 cfs
Resultant Flow Depth at Gutter Flowline (Safety Factor Applied) d = 5.74 7.48 inches
Resultant Flow Depth at Street Crown (Safety Factor Applied) dCROWN = 0.00 0.00 inches
MINOR STORM Allowable Capacity is based on Spread Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Spread Criterion Qallow = 18.3 18.3 cfs
Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
Version 4.05 Released March 2017
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
Willow Bend - Holly Street
DP3
17-4088-UD-Inlet_v4.05.xlsm, DP3 1/24/2019, 3:45 PM
Design Information (Input) MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a') aLOCAL = 3.0 3.0 inches
Total Number of Units in the Inlet (Grate or Curb Opening) No = 2 2
Length of a Single Unit Inlet (Grate or Curb Opening) Lo = 5.00 5.00 ft
Width of a Unit Grate (cannot be greater than W, Gutter Width) Wo = N/A N/A ft
Clogging Factor for a Single Unit Grate (typical min. value = 0.5) Cf-G = N/A N/A
Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1) Cf-C = 0.10 0.10
Street Hydraulics: OK - Q < Allowable Street Capacity' MINOR MAJOR
Design Discharge for Half of Street (from Sheet Inlet Management ) Qo = 0.6 1.6 cfs
Water Spread Width T = 2.0 5.4 ft
Water Depth at Flowline (outside of local depression) d = 2.0 2.8 inches
Water Depth at Street Crown (or at TMAX) dCROWN = 0.0 0.0 inches
Ratio of Gutter Flow to Design Flow Eo = 1.013 0.865
Discharge outside the Gutter Section W, carried in Section Tx Qx = 0.0 0.2 cfs
Discharge within the Gutter Section W Qw = 0.6 1.4 cfs
Discharge Behind the Curb Face QBACK = 0.0 0.0 cfs
Flow Area within the Gutter Section W AW = 0.17 0.30 sq ft
Velocity within the Gutter Section W VW = 3.6 4.7 fps
Water Depth for Design Condition dLOCAL = 5.0 5.8 inches
Grate Analysis (Calculated) MINOR MAJOR
Total Length of Inlet Grate Opening L = N/A N/A ft
Ratio of Grate Flow to Design Flow Eo-GRATE = N/A N/A
Under No-Clogging Condition MINOR MAJOR
Minimum Velocity Where Grate Splash-Over Begins Vo = N/A N/A fps
Interception Rate of Frontal Flow Rf = N/A N/A
Interception Rate of Side Flow Rx = N/A N/A
Interception Capacity Qi = N/A N/A cfs
Under Clogging Condition MINOR MAJOR
Clogging Coefficient for Multiple-unit Grate Inlet GrateCoef = N/A N/A
Clogging Factor for Multiple-unit Grate Inlet GrateClog = N/A N/A
Effective (unclogged) Length of Multiple-unit Grate Inlet Le = N/A N/A ft
Minimum Velocity Where Grate Splash-Over Begins Vo = N/A N/A fps
Interception Rate of Frontal Flow Rf = N/A N/A
Interception Rate of Side Flow Rx = N/A N/A
Actual Interception Capacity Qa = N/A N/A cfs
Carry-Over Flow = Qo-Qa (to be applied to curb opening or next d/s inlet) Qb = N/A N/A cfs
Curb or Slotted Inlet Opening Analysis (Calculated) MINOR MAJOR
Equivalent Slope Se (based on grate carry-over) Se = 0.208 0.183 ft/ft
Required Length LT to Have 100% Interception LT = 3.36 5.96 ft
Under No-Clogging Condition MINOR MAJOR
Effective Length of Curb Opening or Slotted Inlet (minimum of L, LT) L = 3.36 5.96 ft
Interception Capacity Qi = 0.6 1.6 cfs
Under Clogging Condition MINOR MAJOR
Clogging Coefficient CurbCoef = 1.25 1.25
Clogging Factor for Multiple-unit Curb Opening or Slotted Inlet CurbClog = 0.06 0.06
Effective (Unclogged) Length Le = 9.37 9.37 ft
Actual Interception Capacity Qa = 0.6 1.6 cfs
Carry-Over Flow = Qb(GRATE)-Qa Qb = 0.0 0.0 cfs
Summary MINOR MAJOR
Total Inlet Interception Capacity Q = 0.6 1.6 cfs
Total Inlet Carry-Over Flow (flow bypassing inlet) Qb = 0.0 0.0 cfs
Capture Percentage = Qa/Qo = C% = 100 100 %
INLET ON A CONTINUOUS GRADE
Version 4.05 Released March 2017
CDOT Type R Curb OpeningCDOT Type R Curb Opening
17-4088-UD-Inlet_v4.05.xlsm, DP3 1/24/2019, 3:45 PM
Project:
Inlet ID:
Gutter Geometry (Enter data in the blue cells)
Maximum Allowable Width for Spread Behind Curb TBACK = 8.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb) SBACK = 0.020 ft/ft
Manning's Roughness Behind Curb (typically between 0.012 and 0.020) nBACK = 0.016
Height of Curb at Gutter Flow Line HCURB = 6.00 inches
Distance from Curb Face to Street Crown TCROWN = 40.0 ft
Gutter Width W = 2.00 ft
Street Transverse Slope SX = 0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft) SW = 0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO = 0.018 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020) nSTREET = 0.015
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX = 17.0 17.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX = 6.0 8.3 inches
Allow Flow Depth at Street Crown (leave blank for no) check = yes
Maximum Capacity for 1/2 Street based On Allowable Spread Minor Storm Major Storm
Water Depth without Gutter Depression (Eq. ST-2) y = 4.08 4.08 inches
Vertical Depth between Gutter Lip and Gutter Flowline (usually 2") dC = 2.0 2.0 inches
Gutter Depression (dC - (W * Sx * 12)) a = 1.51 1.51 inches
Water Depth at Gutter Flowline d = 5.59 5.59 inches
Allowable Spread for Discharge outside the Gutter Section W (T - W) TX = 15.0 15.0 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.350 0.350
Discharge outside the Gutter Section W, carried in Section TX QX = 10.1 10.1 cfs
Discharge within the Gutter Section W (QT - QX) QW = 5.4 5.4 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 0.0 cfs
Maximum Flow Based On Allowable Spread QT = 15.5 15.5 cfs
Flow Velocity within the Gutter Section V = 7.1 7.1 fps
V*d Product: Flow Velocity times Gutter Flowline Depth V*d = 3.3 3.3
Maximum Capacity for 1/2 Street based on Allowable Depth Minor Storm Major Storm
Theoretical Water Spread TTH = 18.7 28.3 ft
Theoretical Spread for Discharge outside the Gutter Section W (T - W) TX TH = 16.7 26.3 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.318 0.206
Theoretical Discharge outside the Gutter Section W, carried in Section TX TH QX TH = 13.4 45.1 cfs
Actual Discharge outside the Gutter Section W, (limited by distance TCROWN) QX = 13.4 45.1 cfs
Discharge within the Gutter Section W (Qd - QX) QW = 6.3 11.7 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 2.8 cfs
Total Discharge for Major & Minor Storm (Pre-Safety Factor) Q = 19.7 59.6 cfs
Average Flow Velocity Within the Gutter Section V = 7.5 9.6 fps
V*d Product: Flow Velocity Times Gutter Flowline Depth V*d = 3.8 6.7
Slope-Based Depth Safety Reduction Factor for Major & Minor (d > 6") Storm R = 1.00 0.91
Max Flow Based on Allowable Depth (Safety Factor Applied) Qd = 19.7 54.1 cfs
Resultant Flow Depth at Gutter Flowline (Safety Factor Applied) d = 6.00 8.07 inches
Resultant Flow Depth at Street Crown (Safety Factor Applied) dCROWN = 0.00 0.00 inches
MINOR STORM Allowable Capacity is based on Spread Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Spread Criterion Qallow = 15.5 15.5 cfs
Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
Version 4.05 Released March 2017
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
Willow Bend - Holly Street
DP4
17-4088-UD-Inlet_v4.05.xlsm, DP4 1/24/2019, 3:45 PM
Design Information (Input) MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a') aLOCAL = 3.0 3.0 inches
Total Number of Units in the Inlet (Grate or Curb Opening) No = 3 3
Length of a Single Unit Inlet (Grate or Curb Opening) Lo = 5.00 5.00 ft
Width of a Unit Grate (cannot be greater than W, Gutter Width) Wo = N/A N/A ft
Clogging Factor for a Single Unit Grate (typical min. value = 0.5) Cf-G = N/A N/A
Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1) Cf-C = 0.10 0.10
Street Hydraulics: OK - Q < Allowable Street Capacity' MINOR MAJOR
Design Discharge for Half of Street (from Sheet Inlet Management ) Qo = 3.9 9.3 cfs
Water Spread Width T = 9.4 13.8 ft
Water Depth at Flowline (outside of local depression) d = 3.8 4.8 inches
Water Depth at Street Crown (or at TMAX) dCROWN = 0.0 0.0 inches
Ratio of Gutter Flow to Design Flow Eo = 0.609 0.432
Discharge outside the Gutter Section W, carried in Section Tx Qx = 1.5 5.3 cfs
Discharge within the Gutter Section W Qw = 2.4 4.0 cfs
Discharge Behind the Curb Face QBACK = 0.0 0.0 cfs
Flow Area within the Gutter Section W AW = 0.46 0.64 sq ft
Velocity within the Gutter Section W VW = 5.1 6.3 fps
Water Depth for Design Condition dLOCAL = 6.8 7.8 inches
Grate Analysis (Calculated) MINOR MAJOR
Total Length of Inlet Grate Opening L = N/A N/A ft
Ratio of Grate Flow to Design Flow Eo-GRATE = N/A N/A
Under No-Clogging Condition MINOR MAJOR
Minimum Velocity Where Grate Splash-Over Begins Vo = N/A N/A fps
Interception Rate of Frontal Flow Rf = N/A N/A
Interception Rate of Side Flow Rx = N/A N/A
Interception Capacity Qi = N/A N/A cfs
Under Clogging Condition MINOR MAJOR
Clogging Coefficient for Multiple-unit Grate Inlet GrateCoef = N/A N/A
Clogging Factor for Multiple-unit Grate Inlet GrateClog = N/A N/A
Effective (unclogged) Length of Multiple-unit Grate Inlet Le = N/A N/A ft
Minimum Velocity Where Grate Splash-Over Begins Vo = N/A N/A fps
Interception Rate of Frontal Flow Rf = N/A N/A
Interception Rate of Side Flow Rx = N/A N/A
Actual Interception Capacity Qa = N/A N/A cfs
Carry-Over Flow = Qo-Qa (to be applied to curb opening or next d/s inlet) Qb = N/A N/A cfs
Curb or Slotted Inlet Opening Analysis (Calculated) MINOR MAJOR
Equivalent Slope Se (based on grate carry-over) Se = 0.134 0.101 ft/ft
Required Length LT to Have 100% Interception LT = 10.47 18.59 ft
Under No-Clogging Condition MINOR MAJOR
Effective Length of Curb Opening or Slotted Inlet (minimum of L, LT) L = 10.47 15.00 ft
Interception Capacity Qi = 3.9 8.8 cfs
Under Clogging Condition MINOR MAJOR
Clogging Coefficient CurbCoef = 1.31 1.31
Clogging Factor for Multiple-unit Curb Opening or Slotted Inlet CurbClog = 0.04 0.04
Effective (Unclogged) Length Le = 14.34 14.34 ft
Actual Interception Capacity Qa = 3.9 8.8 cfs
Carry-Over Flow = Qb(GRATE)-Qa Qb = 0.0 0.5 cfs
Summary MINOR MAJOR
Total Inlet Interception Capacity Q = 3.9 8.8 cfs
Total Inlet Carry-Over Flow (flow bypassing inlet) Qb = 0.0 0.5 cfs
Capture Percentage = Qa/Qo = C% = 100 94 %
INLET ON A CONTINUOUS GRADE
Version 4.05 Released March 2017
CDOT Type R Curb OpeningCDOT Type R Curb Opening
17-4088-UD-Inlet_v4.05.xlsm, DP4 1/24/2019, 3:45 PM
Project:
Inlet ID:
Gutter Geometry (Enter data in the blue cells)
Maximum Allowable Width for Spread Behind Curb TBACK = 8.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb) SBACK = 0.020 ft/ft
Manning's Roughness Behind Curb (typically between 0.012 and 0.020) nBACK = 0.016
Height of Curb at Gutter Flow Line HCURB = 6.00 inches
Distance from Curb Face to Street Crown TCROWN = 40.0 ft
Gutter Width W = 2.00 ft
Street Transverse Slope SX = 0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft) SW = 0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO = 0.010 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020) nSTREET = 0.015
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX = 17.0 17.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX = 6.0 8.3 inches
Allow Flow Depth at Street Crown (leave blank for no) check = yes
Maximum Capacity for 1/2 Street based On Allowable Spread Minor Storm Major Storm
Water Depth without Gutter Depression (Eq. ST-2) y = 4.08 4.08 inches
Vertical Depth between Gutter Lip and Gutter Flowline (usually 2") dC = 2.0 2.0 inches
Gutter Depression (dC - (W * Sx * 12)) a = 1.51 1.51 inches
Water Depth at Gutter Flowline d = 5.59 5.59 inches
Allowable Spread for Discharge outside the Gutter Section W (T - W) TX = 15.0 15.0 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.350 0.350
Discharge outside the Gutter Section W, carried in Section TX QX = 7.5 7.5 cfs
Discharge within the Gutter Section W (QT - QX) QW = 4.1 4.1 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 0.0 cfs
Maximum Flow Based On Allowable Spread QT = 11.6 11.6 cfs
Flow Velocity within the Gutter Section V = 5.3 5.3 fps
V*d Product: Flow Velocity times Gutter Flowline Depth V*d = 2.5 2.5
Maximum Capacity for 1/2 Street based on Allowable Depth Minor Storm Major Storm
Theoretical Water Spread TTH = 18.7 28.3 ft
Theoretical Spread for Discharge outside the Gutter Section W (T - W) TX TH = 16.7 26.3 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.318 0.206
Theoretical Discharge outside the Gutter Section W, carried in Section TX TH QX TH = 10.0 33.6 cfs
Actual Discharge outside the Gutter Section W, (limited by distance TCROWN) QX = 10.0 33.6 cfs
Discharge within the Gutter Section W (Qd - QX) QW = 4.7 8.7 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 2.1 cfs
Total Discharge for Major & Minor Storm (Pre-Safety Factor) Q = 14.7 44.5 cfs
Average Flow Velocity Within the Gutter Section V = 5.6 7.2 fps
V*d Product: Flow Velocity Times Gutter Flowline Depth V*d = 2.8 5.0
Slope-Based Depth Safety Reduction Factor for Major & Minor (d > 6") Storm R = 1.00 1.00
Max Flow Based on Allowable Depth (Safety Factor Applied) Qd = 14.7 44.5 cfs
Resultant Flow Depth at Gutter Flowline (Safety Factor Applied) d = 6.00 8.30 inches
Resultant Flow Depth at Street Crown (Safety Factor Applied) dCROWN = 0.00 0.00 inches
MINOR STORM Allowable Capacity is based on Spread Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Spread Criterion Qallow = 11.6 11.6 cfs
Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
Version 4.05 Released March 2017
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
Willow Bend - Holly Street
DP5
17-4088-UD-Inlet_v4.05.xlsm, DP5 1/24/2019, 3:45 PM
Design Information (Input) MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a') aLOCAL = 3.0 3.0 inches
Total Number of Units in the Inlet (Grate or Curb Opening) No = 2 2
Length of a Single Unit Inlet (Grate or Curb Opening) Lo = 5.00 5.00 ft
Width of a Unit Grate (cannot be greater than W, Gutter Width) Wo = N/A N/A ft
Clogging Factor for a Single Unit Grate (typical min. value = 0.5) Cf-G = N/A N/A
Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1) Cf-C = 0.10 0.10
Street Hydraulics: OK - Q < Allowable Street Capacity' MINOR MAJOR
Design Discharge for Half of Street (from Sheet Inlet Management ) Qo = 2.1 6.1 cfs
Water Spread Width T = 8.0 13.1 ft
Water Depth at Flowline (outside of local depression) d = 3.4 4.7 inches
Water Depth at Street Crown (or at TMAX) dCROWN = 0.0 0.0 inches
Ratio of Gutter Flow to Design Flow Eo = 0.688 0.454
Discharge outside the Gutter Section W, carried in Section Tx Qx = 0.7 3.4 cfs
Discharge within the Gutter Section W Qw = 1.4 2.8 cfs
Discharge Behind the Curb Face QBACK = 0.0 0.0 cfs
Flow Area within the Gutter Section W AW = 0.41 0.61 sq ft
Velocity within the Gutter Section W VW = 3.5 4.6 fps
Water Depth for Design Condition dLOCAL = 6.4 7.7 inches
Grate Analysis (Calculated) MINOR MAJOR
Total Length of Inlet Grate Opening L = N/A N/A ft
Ratio of Grate Flow to Design Flow Eo-GRATE = N/A N/A
Under No-Clogging Condition MINOR MAJOR
Minimum Velocity Where Grate Splash-Over Begins Vo = N/A N/A fps
Interception Rate of Frontal Flow Rf = N/A N/A
Interception Rate of Side Flow Rx = N/A N/A
Interception Capacity Qi = N/A N/A cfs
Under Clogging Condition MINOR MAJOR
Clogging Coefficient for Multiple-unit Grate Inlet GrateCoef = N/A N/A
Clogging Factor for Multiple-unit Grate Inlet GrateClog = N/A N/A
Effective (unclogged) Length of Multiple-unit Grate Inlet Le = N/A N/A ft
Minimum Velocity Where Grate Splash-Over Begins Vo = N/A N/A fps
Interception Rate of Frontal Flow Rf = N/A N/A
Interception Rate of Side Flow Rx = N/A N/A
Actual Interception Capacity Qa = N/A N/A cfs
Carry-Over Flow = Qo-Qa (to be applied to curb opening or next d/s inlet) Qb = N/A N/A cfs
Curb or Slotted Inlet Opening Analysis (Calculated) MINOR MAJOR
Equivalent Slope Se (based on grate carry-over) Se = 0.149 0.105 ft/ft
Required Length LT to Have 100% Interception LT = 7.04 14.28 ft
Under No-Clogging Condition MINOR MAJOR
Effective Length of Curb Opening or Slotted Inlet (minimum of L, LT) L = 7.04 10.00 ft
Interception Capacity Qi = 2.1 5.4 cfs
Under Clogging Condition MINOR MAJOR
Clogging Coefficient CurbCoef = 1.25 1.25
Clogging Factor for Multiple-unit Curb Opening or Slotted Inlet CurbClog = 0.06 0.06
Effective (Unclogged) Length Le = 9.37 9.37 ft
Actual Interception Capacity Qa = 2.1 5.3 cfs
Carry-Over Flow = Qb(GRATE)-Qa Qb = 0.0 0.8 cfs
Summary MINOR MAJOR
Total Inlet Interception Capacity Q = 2.1 5.3 cfs
Total Inlet Carry-Over Flow (flow bypassing inlet) Qb = 0.0 0.8 cfs
Capture Percentage = Qa/Qo = C% = 100 87 %
INLET ON A CONTINUOUS GRADE
Version 4.05 Released March 2017
CDOT Type R Curb OpeningCDOT Type R Curb Opening
17-4088-UD-Inlet_v4.05.xlsm, DP5 1/24/2019, 3:45 PM
Project:
Inlet ID:
Gutter Geometry (Enter data in the blue cells)
Maximum Allowable Width for Spread Behind Curb TBACK = 8.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb) SBACK = 0.020 ft/ft
Manning's Roughness Behind Curb (typically between 0.012 and 0.020) nBACK = 0.016
Height of Curb at Gutter Flow Line HCURB = 6.00 inches
Distance from Curb Face to Street Crown TCROWN = 40.0 ft
Gutter Width W = 2.00 ft
Street Transverse Slope SX = 0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft) SW = 0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO = 0.019 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020) nSTREET = 0.015
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX = 17.0 17.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX = 6.0 8.3 inches
Allow Flow Depth at Street Crown (leave blank for no) check = yes
Maximum Capacity for 1/2 Street based On Allowable Spread Minor Storm Major Storm
Water Depth without Gutter Depression (Eq. ST-2) y = 4.08 4.08 inches
Vertical Depth between Gutter Lip and Gutter Flowline (usually 2") dC = 2.0 2.0 inches
Gutter Depression (dC - (W * Sx * 12)) a = 1.51 1.51 inches
Water Depth at Gutter Flowline d = 5.59 5.59 inches
Allowable Spread for Discharge outside the Gutter Section W (T - W) TX = 15.0 15.0 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.350 0.350
Discharge outside the Gutter Section W, carried in Section TX QX = 10.4 10.4 cfs
Discharge within the Gutter Section W (QT - QX) QW = 5.6 5.6 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 0.0 cfs
Maximum Flow Based On Allowable Spread QT = 16.0 16.0 cfs
Flow Velocity within the Gutter Section V = 7.3 7.3 fps
V*d Product: Flow Velocity times Gutter Flowline Depth V*d = 3.4 3.4
Maximum Capacity for 1/2 Street based on Allowable Depth Minor Storm Major Storm
Theoretical Water Spread TTH = 18.7 28.3 ft
Theoretical Spread for Discharge outside the Gutter Section W (T - W) TX TH = 16.7 26.3 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.318 0.206
Theoretical Discharge outside the Gutter Section W, carried in Section TX TH QX TH = 13.8 46.3 cfs
Actual Discharge outside the Gutter Section W, (limited by distance TCROWN) QX = 13.8 46.3 cfs
Discharge within the Gutter Section W (Qd - QX) QW = 6.4 12.0 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 2.9 cfs
Total Discharge for Major & Minor Storm (Pre-Safety Factor) Q = 20.3 61.3 cfs
Average Flow Velocity Within the Gutter Section V = 7.7 9.9 fps
V*d Product: Flow Velocity Times Gutter Flowline Depth V*d = 3.9 6.8
Slope-Based Depth Safety Reduction Factor for Major & Minor (d > 6") Storm R = 1.00 0.87
Max Flow Based on Allowable Depth (Safety Factor Applied) Qd = 20.3 53.3 cfs
Resultant Flow Depth at Gutter Flowline (Safety Factor Applied) d = 6.00 7.97 inches
Resultant Flow Depth at Street Crown (Safety Factor Applied) dCROWN = 0.00 0.00 inches
MINOR STORM Allowable Capacity is based on Spread Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Spread Criterion Qallow = 16.0 16.0 cfs
Minor storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
Major storm max. allowable capacity GOOD - greater than the design flow given on sheet 'Inlet Management'
Version 4.05 Released March 2017
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
Willow Bend - Holly Street
DP6
17-4088-UD-Inlet_v4.05.xlsm, DP6 1/24/2019, 3:45 PM
Design Information (Input) MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a') aLOCAL = 3.0 3.0 inches
Total Number of Units in the Inlet (Grate or Curb Opening) No = 3 3
Length of a Single Unit Inlet (Grate or Curb Opening) Lo = 5.00 5.00 ft
Width of a Unit Grate (cannot be greater than W, Gutter Width) Wo = N/A N/A ft
Clogging Factor for a Single Unit Grate (typical min. value = 0.5) Cf-G = N/A N/A
Clogging Factor for a Single Unit Curb Opening (typical min. value = 0.1) Cf-C = 0.10 0.10
Street Hydraulics: OK - Q < Allowable Street Capacity' MINOR MAJOR
Design Discharge for Half of Street (from Sheet Inlet Management ) Qo = 2.1 6.5 cfs
Water Spread Width T = 6.8 11.7 ft
Water Depth at Flowline (outside of local depression) d = 3.1 4.3 inches
Water Depth at Street Crown (or at TMAX) dCROWN = 0.0 0.0 inches
Ratio of Gutter Flow to Design Flow Eo = 0.769 0.504
Discharge outside the Gutter Section W, carried in Section Tx Qx = 0.5 3.2 cfs
Discharge within the Gutter Section W Qw = 1.6 3.3 cfs
Discharge Behind the Curb Face QBACK = 0.0 0.0 cfs
Flow Area within the Gutter Section W AW = 0.36 0.55 sq ft
Velocity within the Gutter Section W VW = 4.5 5.9 fps
Water Depth for Design Condition dLOCAL = 6.1 7.3 inches
Grate Analysis (Calculated) MINOR MAJOR
Total Length of Inlet Grate Opening L = N/A N/A ft
Ratio of Grate Flow to Design Flow Eo-GRATE = N/A N/A
Under No-Clogging Condition MINOR MAJOR
Minimum Velocity Where Grate Splash-Over Begins Vo = N/A N/A fps
Interception Rate of Frontal Flow Rf = N/A N/A
Interception Rate of Side Flow Rx = N/A N/A
Interception Capacity Qi = N/A N/A cfs
Under Clogging Condition MINOR MAJOR
Clogging Coefficient for Multiple-unit Grate Inlet GrateCoef = N/A N/A
Clogging Factor for Multiple-unit Grate Inlet GrateClog = N/A N/A
Effective (unclogged) Length of Multiple-unit Grate Inlet Le = N/A N/A ft
Minimum Velocity Where Grate Splash-Over Begins Vo = N/A N/A fps
Interception Rate of Frontal Flow Rf = N/A N/A
Interception Rate of Side Flow Rx = N/A N/A
Actual Interception Capacity Qa = N/A N/A cfs
Carry-Over Flow = Qo-Qa (to be applied to curb opening or next d/s inlet) Qb = N/A N/A cfs
Curb or Slotted Inlet Opening Analysis (Calculated) MINOR MAJOR
Equivalent Slope Se (based on grate carry-over) Se = 0.164 0.115 ft/ft
Required Length LT to Have 100% Interception LT = 6.98 14.64 ft
Under No-Clogging Condition MINOR MAJOR
Effective Length of Curb Opening or Slotted Inlet (minimum of L, LT) L = 6.98 14.64 ft
Interception Capacity Qi = 2.1 6.5 cfs
Under Clogging Condition MINOR MAJOR
Clogging Coefficient CurbCoef = 1.31 1.31
Clogging Factor for Multiple-unit Curb Opening or Slotted Inlet CurbClog = 0.04 0.04
Effective (Unclogged) Length Le = 14.34 14.34 ft
Actual Interception Capacity Qa = 2.1 6.5 cfs
Carry-Over Flow = Qb(GRATE)-Qa Qb = 0.0 0.0 cfs
Summary MINOR MAJOR
Total Inlet Interception Capacity Q = 2.1 6.5 cfs
Total Inlet Carry-Over Flow (flow bypassing inlet) Qb = 0.0 0.0 cfs
Capture Percentage = Qa/Qo = C% = 100 100 %
INLET ON A CONTINUOUS GRADE
Version 4.05 Released March 2017
CDOT Type R Curb OpeningCDOT Type R Curb Opening
17-4088-UD-Inlet_v4.05.xlsm, DP6 1/24/2019, 3:45 PM
Project:
Inlet ID:
Gutter Geometry (Enter data in the blue cells)
Maximum Allowable Width for Spread Behind Curb TBACK = 8.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb) SBACK = 0.020 ft/ft
Manning's Roughness Behind Curb (typically between 0.012 and 0.020) nBACK = 0.016
Height of Curb at Gutter Flow Line HCURB = 6.00 inches
Distance from Curb Face to Street Crown TCROWN = 40.0 ft
Gutter Width W = 2.00 ft
Street Transverse Slope SX = 0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft) SW = 0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO = 0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020) nSTREET = 0.015
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX = 17.0 17.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX = 6.0 8.3 inches
Check boxes are not applicable in SUMP conditions
Maximum Capacity for 1/2 Street based On Allowable Spread Minor Storm Major Storm
Water Depth without Gutter Depression (Eq. ST-2) y = 4.08 4.08 inches
Vertical Depth between Gutter Lip and Gutter Flowline (usually 2") dC = 2.0 2.0 inches
Gutter Depression (dC - (W * Sx * 12)) a = 1.51 1.51 inches
Water Depth at Gutter Flowline d = 5.59 5.59 inches
Allowable Spread for Discharge outside the Gutter Section W (T - W) TX = 15.0 15.0 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.350 0.350
Discharge outside the Gutter Section W, carried in Section TX QX = 0.0 0.0 cfs
Discharge within the Gutter Section W (QT - QX) QW = 0.0 0.0 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 0.0 cfs
Maximum Flow Based On Allowable Spread QT = SUMP SUMP cfs
Flow Velocity within the Gutter Section V = 0.0 0.0 fps
V*d Product: Flow Velocity times Gutter Flowline Depth V*d = 0.0 0.0
Maximum Capacity for 1/2 Street based on Allowable Depth Minor Storm Major Storm
Theoretical Water Spread TTH = 18.7 28.3 ft
Theoretical Spread for Discharge outside the Gutter Section W (T - W) TX TH = 16.7 26.3 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.318 0.206
Theoretical Discharge outside the Gutter Section W, carried in Section TX TH QX TH = 0.0 0.0 cfs
Actual Discharge outside the Gutter Section W, (limited by distance TCROWN) QX = 0.0 0.0 cfs
Discharge within the Gutter Section W (Qd - QX) QW = 0.0 0.0 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 0.0 cfs
Total Discharge for Major & Minor Storm (Pre-Safety Factor) Q = 0.0 0.0 cfs
Average Flow Velocity Within the Gutter Section V = 0.0 0.0 fps
V*d Product: Flow Velocity Times Gutter Flowline Depth V*d = 0.0 0.0
Slope-Based Depth Safety Reduction Factor for Major & Minor (d > 6") Storm R = SUMP SUMP
Max Flow Based on Allowable Depth (Safety Factor Applied) Qd = SUMP SUMP cfs
Resultant Flow Depth at Gutter Flowline (Safety Factor Applied) d = inches
Resultant Flow Depth at Street Crown (Safety Factor Applied) dCROWN = inches
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow = SUMP SUMP cfs
Version 4.05 Released March 2017
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
Willow Bend - Holly Street
DP7
17-4088-UD-Inlet_v4.05.xlsm, DP7 1/24/2019, 3:45 PM
Design Information (Input) MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above) alocal = 3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening) No = 3 3
Water Depth at Flowline (outside of local depression) Ponding Depth = 5.6 5.6 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) = N/A N/A feet
Width of a Unit Grate Wo = N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90) Aratio = N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70) Cf (G) = N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60) Cw (G) = N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80) Co (G) = N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) = 5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert = 6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat = 6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5) Theta = 63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet) Wp = 2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10) Cf (C) = 0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7) Cw (C) = 3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70) Co (C) = 0.67 0.67
Grate Flow Analysis (Calculated) MINOR MAJOR
Clogging Coefficient for Multiple Units Coef = N/A N/A
Clogging Factor for Multiple Units Clog = N/A N/A
Grate Capacity as a Weir (based on Modified HEC22 Method) MINOR MAJOR
Interception without Clogging Qwi = N/A N/A cfs
Interception with Clogging Qwa = N/A N/A cfs
Grate Capacity as a Orifice (based on Modified HEC22 Method) MINOR MAJOR
Interception without Clogging Qoi = N/A N/A cfs
Interception with Clogging Qoa = N/A N/A cfs
Grate Capacity as Mixed Flow MINOR MAJOR
Interception without Clogging Qmi = N/A N/A cfs
Interception with Clogging Qma = N/A N/A cfs
Resulting Grate Capacity (assumes clogged condition) QGrate = N/A N/A cfs
Curb Opening Flow Analysis (Calculated) MINOR MAJOR
Clogging Coefficient for Multiple Units Coef = 1.31 1.31
Clogging Factor for Multiple Units Clog = 0.04 0.04
Curb Opening as a Weir (based on Modified HEC22 Method) MINOR MAJOR
Interception without Clogging Qwi = 11.6 11.6 cfs
Interception with Clogging Qwa = 11.1 11.1 cfs
Curb Opening as an Orifice (based on Modified HEC22 Method) MINOR MAJOR
Interception without Clogging Qoi = 28.3 28.3 cfs
Interception with Clogging Qoa = 27.1 27.1 cfs
Curb Opening Capacity as Mixed Flow MINOR MAJOR
Interception without Clogging Qmi = 16.9 16.9 cfs
Interception with Clogging Qma = 16.1 16.1 cfs
Resulting Curb Opening Capacity (assumes clogged condition) QCurb = 11.1 11.1 cfs
Resultant Street Conditions MINOR MAJOR
Total Inlet Length L = 15.00 15.00 feet
Resultant Street Flow Spread (based on street geometry from above) T = 17.0 17.0 ft
Resultant Flow Depth at Street Crown dCROWN = 0.0 0.0 inches
Low Head Performance Reduction (Calculated) MINOR MAJOR
Depth for Grate Midwidth dGrate = N/A N/A ft
Depth for Curb Opening Weir Equation dCurb = 0.30 0.30 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination = 0.53 0.53
Curb Opening Performance Reduction Factor for Long Inlets RFCurb = 0.76 0.76
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate = N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition) Qa = 11.1 11.1 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK) Q PEAK REQUIRED = 4.5 9.6 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
Version 4.05 Released March 2017
H-VertH-Curb
W
Lo (C)
Lo (G)
W o
WP
CDOT Type R Curb Opening
Override Depths
17-4088-UD-Inlet_v4.05.xlsm, DP7 1/24/2019, 3:45 PM
Project:
Inlet ID:
Gutter Geometry (Enter data in the blue cells)
Maximum Allowable Width for Spread Behind Curb TBACK = 8.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb) SBACK = 0.020 ft/ft
Manning's Roughness Behind Curb (typically between 0.012 and 0.020) nBACK = 0.016
Height of Curb at Gutter Flow Line HCURB = 6.00 inches
Distance from Curb Face to Street Crown TCROWN = 28.0 ft
Gutter Width W = 2.00 ft
Street Transverse Slope SX = 0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft) SW = 0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO = 0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020) nSTREET = 0.015
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX = 17.0 17.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX = 6.0 8.3 inches
Check boxes are not applicable in SUMP conditions
Maximum Capacity for 1/2 Street based On Allowable Spread Minor Storm Major Storm
Water Depth without Gutter Depression (Eq. ST-2) y = 4.08 4.08 inches
Vertical Depth between Gutter Lip and Gutter Flowline (usually 2") dC = 2.0 2.0 inches
Gutter Depression (dC - (W * Sx * 12)) a = 1.51 1.51 inches
Water Depth at Gutter Flowline d = 5.59 5.59 inches
Allowable Spread for Discharge outside the Gutter Section W (T - W) TX = 15.0 15.0 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.350 0.350
Discharge outside the Gutter Section W, carried in Section TX QX = 0.0 0.0 cfs
Discharge within the Gutter Section W (QT - QX) QW = 0.0 0.0 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 0.0 cfs
Maximum Flow Based On Allowable Spread QT = SUMP SUMP cfs
Flow Velocity within the Gutter Section V = 0.0 0.0 fps
V*d Product: Flow Velocity times Gutter Flowline Depth V*d = 0.0 0.0
Maximum Capacity for 1/2 Street based on Allowable Depth Minor Storm Major Storm
Theoretical Water Spread TTH = 18.7 28.3 ft
Theoretical Spread for Discharge outside the Gutter Section W (T - W) TX TH = 16.7 26.3 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.318 0.206
Theoretical Discharge outside the Gutter Section W, carried in Section TX TH QX TH = 0.0 0.0 cfs
Actual Discharge outside the Gutter Section W, (limited by distance TCROWN) QX = 0.0 0.0 cfs
Discharge within the Gutter Section W (Qd - QX) QW = 0.0 0.0 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 0.0 cfs
Total Discharge for Major & Minor Storm (Pre-Safety Factor) Q = 0.0 0.0 cfs
Average Flow Velocity Within the Gutter Section V = 0.0 0.0 fps
V*d Product: Flow Velocity Times Gutter Flowline Depth V*d = 0.0 0.0
Slope-Based Depth Safety Reduction Factor for Major & Minor (d > 6") Storm R = SUMP SUMP
Max Flow Based on Allowable Depth (Safety Factor Applied) Qd = SUMP SUMP cfs
Resultant Flow Depth at Gutter Flowline (Safety Factor Applied) d = inches
Resultant Flow Depth at Street Crown (Safety Factor Applied) dCROWN = inches
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow = SUMP SUMP cfs
Version 4.05 Released March 2017
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
Willow Bend - Holly Street
DP8
17-4088-UD-Inlet_v4.05.xlsm, DP8 1/24/2019, 3:45 PM
Design Information (Input) MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above) alocal = 3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening) No = 2 2
Water Depth at Flowline (outside of local depression) Ponding Depth = 5.6 5.6 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) = N/A N/A feet
Width of a Unit Grate Wo = N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90) Aratio = N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70) Cf (G) = N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60) Cw (G) = N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80) Co (G) = N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) = 5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert = 6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat = 6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5) Theta = 63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet) Wp = 2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10) Cf (C) = 0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7) Cw (C) = 3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70) Co (C) = 0.67 0.67
Grate Flow Analysis (Calculated) MINOR MAJOR
Clogging Coefficient for Multiple Units Coef = N/A N/A
Clogging Factor for Multiple Units Clog = N/A N/A
Grate Capacity as a Weir (based on Modified HEC22 Method) MINOR MAJOR
Interception without Clogging Qwi = N/A N/A cfs
Interception with Clogging Qwa = N/A N/A cfs
Grate Capacity as a Orifice (based on Modified HEC22 Method) MINOR MAJOR
Interception without Clogging Qoi = N/A N/A cfs
Interception with Clogging Qoa = N/A N/A cfs
Grate Capacity as Mixed Flow MINOR MAJOR
Interception without Clogging Qmi = N/A N/A cfs
Interception with Clogging Qma = N/A N/A cfs
Resulting Grate Capacity (assumes clogged condition) QGrate = N/A N/A cfs
Curb Opening Flow Analysis (Calculated) MINOR MAJOR
Clogging Coefficient for Multiple Units Coef = 1.25 1.25
Clogging Factor for Multiple Units Clog = 0.06 0.06
Curb Opening as a Weir (based on Modified HEC22 Method) MINOR MAJOR
Interception without Clogging Qwi = 9.3 9.3 cfs
Interception with Clogging Qwa = 8.7 8.7 cfs
Curb Opening as an Orifice (based on Modified HEC22 Method) MINOR MAJOR
Interception without Clogging Qoi = 18.9 18.9 cfs
Interception with Clogging Qoa = 17.7 17.7 cfs
Curb Opening Capacity as Mixed Flow MINOR MAJOR
Interception without Clogging Qmi = 12.3 12.3 cfs
Interception with Clogging Qma = 11.5 11.5 cfs
Resulting Curb Opening Capacity (assumes clogged condition) QCurb = 8.7 8.7 cfs
Resultant Street Conditions MINOR MAJOR
Total Inlet Length L = 10.00 10.00 feet
Resultant Street Flow Spread (based on street geometry from above) T = 17.0 17.0 ft
Resultant Flow Depth at Street Crown dCROWN = 0.0 0.0 inches
Low Head Performance Reduction (Calculated) MINOR MAJOR
Depth for Grate Midwidth dGrate = N/A N/A ft
Depth for Curb Opening Weir Equation dCurb = 0.30 0.30 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination = 0.53 0.53
Curb Opening Performance Reduction Factor for Long Inlets RFCurb = 0.91 0.91
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate = N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition) Qa = 8.7 8.7 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK) Q PEAK REQUIRED = 2.0 5.1 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
Version 4.05 Released March 2017
H-VertH-Curb
W
Lo (C)
Lo (G)
W o
WP
CDOT Type R Curb Opening
Override Depths
17-4088-UD-Inlet_v4.05.xlsm, DP8 1/24/2019, 3:45 PM
Project:
Inlet ID:
Gutter Geometry (Enter data in the blue cells)
Maximum Allowable Width for Spread Behind Curb TBACK = 8.0 ft
Side Slope Behind Curb (leave blank for no conveyance credit behind curb) SBACK = 0.020 ft/ft
Manning's Roughness Behind Curb (typically between 0.012 and 0.020) nBACK = 0.016
Height of Curb at Gutter Flow Line HCURB = 6.00 inches
Distance from Curb Face to Street Crown TCROWN = 39.0 ft
Gutter Width W = 2.00 ft
Street Transverse Slope SX = 0.020 ft/ft
Gutter Cross Slope (typically 2 inches over 24 inches or 0.083 ft/ft) SW = 0.083 ft/ft
Street Longitudinal Slope - Enter 0 for sump condition SO = 0.000 ft/ft
Manning's Roughness for Street Section (typically between 0.012 and 0.020) nSTREET = 0.015
Minor Storm Major Storm
Max. Allowable Spread for Minor & Major Storm TMAX = 17.0 17.0 ft
Max. Allowable Depth at Gutter Flowline for Minor & Major Storm dMAX = 6.0 8.3 inches
Check boxes are not applicable in SUMP conditions
Maximum Capacity for 1/2 Street based On Allowable Spread Minor Storm Major Storm
Water Depth without Gutter Depression (Eq. ST-2) y = 4.08 4.08 inches
Vertical Depth between Gutter Lip and Gutter Flowline (usually 2") dC = 2.0 2.0 inches
Gutter Depression (dC - (W * Sx * 12)) a = 1.51 1.51 inches
Water Depth at Gutter Flowline d = 5.59 5.59 inches
Allowable Spread for Discharge outside the Gutter Section W (T - W) TX = 15.0 15.0 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.350 0.350
Discharge outside the Gutter Section W, carried in Section TX QX = 0.0 0.0 cfs
Discharge within the Gutter Section W (QT - QX) QW = 0.0 0.0 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 0.0 cfs
Maximum Flow Based On Allowable Spread QT = SUMP SUMP cfs
Flow Velocity within the Gutter Section V = 0.0 0.0 fps
V*d Product: Flow Velocity times Gutter Flowline Depth V*d = 0.0 0.0
Maximum Capacity for 1/2 Street based on Allowable Depth Minor Storm Major Storm
Theoretical Water Spread TTH = 18.7 28.3 ft
Theoretical Spread for Discharge outside the Gutter Section W (T - W) TX TH = 16.7 26.3 ft
Gutter Flow to Design Flow Ratio by FHWA HEC-22 method (Eq. ST-7) EO = 0.318 0.206
Theoretical Discharge outside the Gutter Section W, carried in Section TX TH QX TH = 0.0 0.0 cfs
Actual Discharge outside the Gutter Section W, (limited by distance TCROWN) QX = 0.0 0.0 cfs
Discharge within the Gutter Section W (Qd - QX) QW = 0.0 0.0 cfs
Discharge Behind the Curb (e.g., sidewalk, driveways, & lawns) QBACK = 0.0 0.0 cfs
Total Discharge for Major & Minor Storm (Pre-Safety Factor) Q = 0.0 0.0 cfs
Average Flow Velocity Within the Gutter Section V = 0.0 0.0 fps
V*d Product: Flow Velocity Times Gutter Flowline Depth V*d = 0.0 0.0
Slope-Based Depth Safety Reduction Factor for Major & Minor (d > 6") Storm R = SUMP SUMP
Max Flow Based on Allowable Depth (Safety Factor Applied) Qd = SUMP SUMP cfs
Resultant Flow Depth at Gutter Flowline (Safety Factor Applied) d = inches
Resultant Flow Depth at Street Crown (Safety Factor Applied) dCROWN = inches
MINOR STORM Allowable Capacity is based on Depth Criterion Minor Storm Major Storm
MAJOR STORM Allowable Capacity is based on Depth Criterion Qallow = SUMP SUMP cfs
Version 4.05 Released March 2017
ALLOWABLE CAPACITY FOR ONE-HALF OF STREET (Minor & Major Storm)
(Based on Regulated Criteria for Maximum Allowable Flow Depth and Spread)
Willow Bend - Holly Street
DP9
17-4088-UD-Inlet_v4.05.xlsm, DP9 1/24/2019, 3:45 PM
Design Information (Input) MINOR MAJOR
Type of Inlet Type =
Local Depression (additional to continuous gutter depression 'a' from above) alocal = 3.00 3.00 inches
Number of Unit Inlets (Grate or Curb Opening) No = 2 2
Water Depth at Flowline (outside of local depression) Ponding Depth = 5.6 5.6 inches
Grate Information MINOR MAJOR
Length of a Unit Grate Lo (G) = N/A N/A feet
Width of a Unit Grate Wo = N/A N/A feet
Area Opening Ratio for a Grate (typical values 0.15-0.90) Aratio = N/A N/A
Clogging Factor for a Single Grate (typical value 0.50 - 0.70) Cf (G) = N/A N/A
Grate Weir Coefficient (typical value 2.15 - 3.60) Cw (G) = N/A N/A
Grate Orifice Coefficient (typical value 0.60 - 0.80) Co (G) = N/A N/A
Curb Opening Information MINOR MAJOR
Length of a Unit Curb Opening Lo (C) = 5.00 5.00 feet
Height of Vertical Curb Opening in Inches Hvert = 6.00 6.00 inches
Height of Curb Orifice Throat in Inches Hthroat = 6.00 6.00 inches
Angle of Throat (see USDCM Figure ST-5) Theta = 63.40 63.40 degrees
Side Width for Depression Pan (typically the gutter width of 2 feet) Wp = 2.00 2.00 feet
Clogging Factor for a Single Curb Opening (typical value 0.10) Cf (C) = 0.10 0.10
Curb Opening Weir Coefficient (typical value 2.3-3.7) Cw (C) = 3.60 3.60
Curb Opening Orifice Coefficient (typical value 0.60 - 0.70) Co (C) = 0.67 0.67
Grate Flow Analysis (Calculated) MINOR MAJOR
Clogging Coefficient for Multiple Units Coef = N/A N/A
Clogging Factor for Multiple Units Clog = N/A N/A
Grate Capacity as a Weir (based on Modified HEC22 Method) MINOR MAJOR
Interception without Clogging Qwi = N/A N/A cfs
Interception with Clogging Qwa = N/A N/A cfs
Grate Capacity as a Orifice (based on Modified HEC22 Method) MINOR MAJOR
Interception without Clogging Qoi = N/A N/A cfs
Interception with Clogging Qoa = N/A N/A cfs
Grate Capacity as Mixed Flow MINOR MAJOR
Interception without Clogging Qmi = N/A N/A cfs
Interception with Clogging Qma = N/A N/A cfs
Resulting Grate Capacity (assumes clogged condition) QGrate = N/A N/A cfs
Curb Opening Flow Analysis (Calculated) MINOR MAJOR
Clogging Coefficient for Multiple Units Coef = 1.25 1.25
Clogging Factor for Multiple Units Clog = 0.06 0.06
Curb Opening as a Weir (based on Modified HEC22 Method) MINOR MAJOR
Interception without Clogging Qwi = 9.3 9.3 cfs
Interception with Clogging Qwa = 8.7 8.7 cfs
Curb Opening as an Orifice (based on Modified HEC22 Method) MINOR MAJOR
Interception without Clogging Qoi = 18.9 18.9 cfs
Interception with Clogging Qoa = 17.7 17.7 cfs
Curb Opening Capacity as Mixed Flow MINOR MAJOR
Interception without Clogging Qmi = 12.3 12.3 cfs
Interception with Clogging Qma = 11.5 11.5 cfs
Resulting Curb Opening Capacity (assumes clogged condition) QCurb = 8.7 8.7 cfs
Resultant Street Conditions MINOR MAJOR
Total Inlet Length L = 10.00 10.00 feet
Resultant Street Flow Spread (based on street geometry from above) T = 17.0 17.0 ft
Resultant Flow Depth at Street Crown dCROWN = 0.0 0.0 inches
Low Head Performance Reduction (Calculated) MINOR MAJOR
Depth for Grate Midwidth dGrate = N/A N/A ft
Depth for Curb Opening Weir Equation dCurb = 0.30 0.30 ft
Combination Inlet Performance Reduction Factor for Long Inlets RFCombination = 0.53 0.53
Curb Opening Performance Reduction Factor for Long Inlets RFCurb = 0.91 0.91
Grated Inlet Performance Reduction Factor for Long Inlets RFGrate = N/A N/A
MINOR MAJOR
Total Inlet Interception Capacity (assumes clogged condition) Qa = 8.7 8.7 cfs
Inlet Capacity IS GOOD for Minor and Major Storms(>Q PEAK) Q PEAK REQUIRED = 1.1 2.4 cfs
CDOT Type R Curb Opening
INLET IN A SUMP OR SAG LOCATION
Version 4.05 Released March 2017
H-VertH-Curb
W
Lo (C)
Lo (G)
W o
WP
CDOT Type R Curb Opening
Override Depths
17-4088-UD-Inlet_v4.05.xlsm, DP9 1/24/2019, 3:45 PM
Scenario: 5 - Year
PIPE - 26
PIPE - 25
PIPE - 24
PIPE - 23
PIPE - 22
PIPE - 4
PIPE - 28
PIPE - 27
O-1
STM INLET-01
STM INLET-0.1
STM INLET-00
STM INLET-07
STM INLET-06
STM INLET-05
STM INLET-04
STM INLET-03
STM INLET-02
STM MH-10
STM MH-09
STM MH-08
STM MH-07
STM MH-06
STM MH-05
STM MH-04
STM MH-03
STM MH-02
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-16661/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 5 - Year
FlexTable: Conduit Table
Froude Number (Normal)
Velocity(ft/s)
Slope (Calculated)
(ft/ft)
Manning's n
Length (User
Defined)(ft)
Flow / Capacity (Design)
(%)
Diameter(in)
Invert (Stop)
(ft)
Invert (Start)
(ft)
Stop NodeStart Node
1.1891.130.0070.01382.522.818.05,193.465,194.03STM INLET-00STM INLET-0.1
1.0510.110.0050.01349.71.542.05,191.015,191.26O-1STM INLET-00
2.4379.390.0300.01312.735.218.05,231.035,231.41STM MH-09STM INLET-07
1.9414.300.0200.01312.64.718.05,228.165,228.41STM MH-08STM INLET-06
1.9274.110.0200.01312.74.018.05,224.605,224.85STM MH-07STM INLET-05
2.0137.080.0200.01312.626.318.05,211.125,211.37STM MH-05STM INLET-04
2.0145.940.0200.01312.714.118.05,208.055,208.30STM MH-04STM INLET-03
2.0145.940.0200.01312.714.118.05,201.915,202.16STM MH-03STM INLET-02
1.1324.130.0050.013343.16.342.05,194.105,195.81STM MH-02STM INLET-01
1.1942.110.0050.013152.327.742.05,191.465,192.27STM INLET-00STM MH-10
1.5938.000.0090.013151.720.842.05,192.475,193.89STM MH-10STM MH-02
3.23213.270.0430.013134.718.530.05,194.895,200.71STM MH-02STM MH-03
2.2339.780.0210.013297.123.230.05,200.915,207.05STM MH-03STM MH-04
1.4017.160.0100.013296.952.224.05,207.555,210.42STM MH-04STM MH-05
2.2298.690.0220.013297.122.924.05,210.625,217.21STM MH-05STM MH-06
2.2468.740.0230.013297.022.724.05,217.415,224.10STM MH-06STM MH-07
2.4209.650.0300.013112.139.018.05,224.605,227.96STM MH-07STM MH-08
2.1778.690.0240.013110.039.118.05,228.165,230.83STM MH-08STM MH-09
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 5 - Year
FlexTable: Copy of Conduit Table
Hydraulic Grade Line
(Out)(ft)
Hydraulic Grade Line
(In)(ft)
Stop NodeStart Node
5,196.415,196.44STM INLET-00STM INLET-0.1
5,196.415,196.41O-1STM INLET-00
5,232.155,232.39STM MH-09STM INLET-07
5,229.275,229.27STM MH-08STM INLET-06
5,225.325,225.30STM MH-07STM INLET-05
5,211.955,212.13STM MH-05STM INLET-04
5,208.465,208.85STM MH-04STM INLET-03
5,202.325,202.71STM MH-03STM INLET-02
5,196.565,196.54STM MH-02STM INLET-01
5,196.415,196.47STM INLET-00STM MH-10
5,196.475,196.49STM MH-10STM MH-02
5,196.565,202.05STM MH-02STM MH-03
5,202.385,208.30STM MH-03STM MH-04
5,208.585,211.64STM MH-04STM MH-05
5,211.955,218.20STM MH-05STM MH-06
5,218.065,225.09STM MH-06STM MH-07
5,225.255,228.99STM MH-07STM MH-08
5,229.275,231.81STM MH-08STM MH-09
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]
Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 5 - Year
FlexTable: Catch Basin Table
Flow (Known)(cfs)
Manning's n (Inlet)
NotesHydraulic Grade Line
(In)(ft)
Elevation (Invert)
(ft)
Elevation (Rim)(ft)
Elevation (Ground)
(ft)
Label
4.5015' TYPE 'R'5,196.545,195.815,201.475,201.47STM INLET-01
2.100.01315' TYPE'R'5,202.715,202.165,209.785,209.78STM INLET-02
2.100.01310' TYPE 'R'5,208.855,208.055,215.555,215.55STM INLET-03
3.900.01315' TYPE'R'5,212.135,211.125,218.335,218.33STM INLET-04
0.600.01310' TYPE 'R'5,225.305,224.605,231.815,231.81STM INLET-05
0.700.01310' TYPE 'R'5,229.275,228.165,234.615,234.61STM INLET-06
6.400.01315' TYPE'R'5,232.395,231.165,237.365,237.36STM INLET-07
1.1010' TYPE 'R'5,196.415,191.265,205.625,205.62STM INLET-00
2.0010' TYPE 'R'5,196.445,194.035,205.845,205.84STM INLET-0.1
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 5 - Year
FlexTable: Manhole Table
NotesHeadloss Coefficient (Standard)
Hydraulic Grade Line
(Out)(ft)
Hydraulic Grade Line
(In)(ft)
Flow (Total Out)(cfs)
Elevation (Invert in 1)(ft)
Elevation (Rim)(ft)
Elevation (Ground)
(ft)
LabelID
5' MANHOLE0.8005,231.815,232.156.405,231.035,237.235,237.23STM MH-0932
5' MANHOLE0.6005,228.995,229.277.105,228.165,234.485,234.48STM MH-0834
5' MANHOLE0.6005,225.095,225.327.705,224.605,231.685,231.68STM MH-0736
5' MANHOLE0.5005,218.205,218.397.705,217.415,224.265,224.26STM MH-0637
5' MANHOLE0.6005,211.645,211.9511.605,210.625,218.195,218.19STM MH-0539
5' MANHOLE0.6005,208.305,208.5913.705,207.555,215.425,215.42STM MH-0441
5' MANHOLE0.6005,202.055,202.3815.805,200.915,209.655,209.65STM MH-0343
8' MANHOLE0.6005,196.495,196.5620.305,194.895,207.025,207.02STM MH-0244
8' MANHOLE0.0005,196.475,196.4720.305,192.475,206.185,206.18STM MH-1045
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 5 - Year
Profile Report
Engineering Profile - Profile - 1 (17-4088_StormCAD.stsw)
5,190.00
5,195.00
5,200.00
5,205.00
5,210.00
5,215.00
5,220.00
5,225.00
5,230.00
5,235.00
5,240.00
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00
Station (ft)
STM MH-09
Rim: 5,237.23 ftInvert: 5,230.58 ft
STM MH-02
Rim: 5,207.02 ftInvert: 5,193.43 ft
STM MH-03
Rim: 5,209.65 ftInvert: 5,200.34 ft
STM MH-04
Rim: 5,215.42 ftInvert: 5,206.68 ft
STM MH-05
Rim: 5,218.19 ftInvert: 5,210.13 ft
STM MH-06
Rim: 5,224.26 ftInvert: 5,217.21 ft
STM MH-07
Rim: 5,231.68 ftInvert: 5,223.81 ft
STM MH-08
Rim: 5,234.48 ftInvert: 5,227.71 ft
STM INLET-01
Rim: 5,201.47 ftInvert: 5,195.81 ft
PIPE - 7 (1): 297.1 ft @ 0.022 ft/ft
RCP
PIPE - 7: 297.0 ft @ 0.023 ft/ft
RCP
PIPE - 6: 112.1 ft @ 0.030 ft/ft
RCP
PIPE - 19: 110.0 ft @ 0.024 ft/ft
RCP
PIPE - 17: 343.1 ft @ 0.005 ft/ft RCP
PIPE - 3: 134.7 ft @
0.043 ft/ft
RCP
PIPE - 8 (1): 297.1 ft @ 0.021 ft/ft
RCP
PIPE - 8: 296.9 ft @ 0.010 ft/ft
RCP
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 5 - Year
Profile Report
Engineering Profile - Profile - 2 (17-4088_StormCAD.stsw)
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 5 - Year
Profile Report
Engineering Profile - Profile - 3 (17-4088_StormCAD.stsw)
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 5 - Year
Profile Report
Engineering Profile - Profile - 4 (17-4088_StormCAD.stsw)
Ele
va
tio
n (
ft)
PIPE - 28: 12.7 ft @ 0.020 ft/ft
RCP
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 5 - Year
Profile Report
Engineering Profile - Profile - 5 (17-4088_StormCAD.stsw)
Ele
va
tio
n (
ft)
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 5 - Year
Profile Report
Engineering Profile - Profile - 6 (17-4088_StormCAD.stsw)
Ele
va
tio
n (
ft)
PIPE - 26: 12.6 ft @ 0.020 ft/ft
RCP
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 5 - Year
Profile Report
Engineering Profile - Profile - 7 (17-4088_StormCAD.stsw)
Ele
va
tio
n (
ft)
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 5 - Year
Profile Report
Engineering Profile - Profile - 8 (17-4088_StormCAD.stsw)
Ele
va
tio
n (
ft)
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 5 - Year
Profile Report
Engineering Profile - Profile - 9 (17-4088_StormCAD.stsw)
Ele
va
tio
n (
ft)
PIP
E - 23: 12.7 ft @
0.030 ft/ft
RC
P
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 100 - Year
FlexTable: Conduit Table
Froude Number (Normal)
Velocity(ft/s)
Slope (Calculated)
(ft/ft)
Manning's n
Length (User
Defined)(ft)
Flow / Capacity (Design)
(%)
Diameter(in)
Invert (Stop)
(ft)
Invert (Start)
(ft)
Stop NodeStart Node
1.1132.890.0070.01382.558.218.05,193.465,194.03STM INLET-00STM INLET-0.1
1.0990.250.0050.01349.73.442.05,191.015,191.26O-1STM INLET-00
2.1148.260.0300.01312.780.318.05,231.035,231.41STM MH-09STM INLET-07
2.0030.910.0200.01312.610.818.05,228.165,228.41STM MH-08STM INLET-06
2.0005.390.0200.01312.710.118.05,224.605,224.85STM MH-07STM INLET-05
1.8615.260.0200.01312.662.618.05,211.125,211.37STM MH-05STM INLET-04
1.9837.820.0200.01312.737.718.05,208.055,208.30STM MH-04STM INLET-03
1.9817.850.0200.01312.738.418.05,201.915,202.16STM MH-03STM INLET-02
1.1591.000.0050.013343.113.542.05,194.105,195.81STM MH-02STM INLET-01
1.0954.980.0050.013152.365.342.05,191.465,192.27STM INLET-00STM MH-10
1.5264.980.0090.013151.749.242.05,192.475,193.89STM MH-10STM MH-02
3.12716.900.0430.013134.744.930.05,194.895,200.71STM MH-02STM MH-03
2.10812.310.0210.013297.155.330.05,200.915,207.05STM MH-03STM MH-04
1.0718.590.0100.013296.9121.424.05,207.555,210.42STM MH-04STM MH-05
2.12010.860.0220.013297.152.524.05,210.625,217.21STM MH-05STM MH-06
2.13810.920.0230.013297.052.124.05,217.415,224.10STM MH-06STM MH-07
1.99911.630.0300.013112.189.118.05,224.605,227.96STM MH-07STM MH-08
1.79710.470.0240.013110.089.218.05,228.165,230.83STM MH-08STM MH-09
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 100 - Year
FlexTable: Copy of Conduit Table
Hydraulic Grade Line
(Out)(ft)
Hydraulic Grade Line
(In)(ft)
Stop NodeStart Node
5,200.425,200.62STM INLET-00STM INLET-0.1
5,200.425,200.42O-1STM INLET-00
5,233.175,233.42STM MH-09STM INLET-07
5,230.205,230.20STM MH-08STM INLET-06
5,226.065,226.06STM MH-07STM INLET-05
5,214.505,214.60STM MH-05STM INLET-04
5,209.595,209.59STM MH-04STM INLET-03
5,203.515,203.53STM MH-03STM INLET-02
5,201.345,201.37STM MH-02STM INLET-01
5,200.425,200.77STM INLET-00STM MH-10
5,200.775,201.11STM MH-10STM MH-02
5,201.345,202.80STM MH-02STM MH-03
5,203.515,208.99STM MH-03STM MH-04
5,209.595,213.81STM MH-04STM MH-05
5,214.505,218.73STM MH-05STM MH-06
5,219.105,225.62STM MH-06STM MH-07
5,226.065,229.39STM MH-07STM MH-08
5,230.205,232.32STM MH-08STM MH-09
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]
Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 100 - Year
FlexTable: Catch Basin Table
Flow (Known)(cfs)
Manning's n (Inlet)
NotesHydraulic Grade Line
(In)(ft)
Elevation (Invert)
(ft)
Elevation (Rim)(ft)
Elevation (Ground)
(ft)
Label
9.6015' TYPE 'R'5,201.375,195.815,201.475,201.47STM INLET-01
5.700.01315' TYPE'R'5,203.535,202.165,209.785,209.78STM INLET-02
5.600.01310' TYPE 'R'5,209.595,208.055,215.555,215.55STM INLET-03
9.300.01315' TYPE'R'5,214.605,211.125,218.335,218.33STM INLET-04
1.500.01310' TYPE 'R'5,226.065,224.605,231.815,231.81STM INLET-05
1.600.01310' TYPE 'R'5,230.205,228.165,234.615,234.61STM INLET-06
14.600.01315' TYPE'R'5,233.425,231.165,237.365,237.36STM INLET-07
2.4010' TYPE 'R'5,200.425,191.265,205.625,205.62STM INLET-00
5.1010' TYPE 'R'5,200.625,194.035,205.845,205.84STM INLET-0.1
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 100 - Year
FlexTable: Manhole Table
NotesHeadloss Coefficient (Standard)
Hydraulic Grade Line
(Out)(ft)
Hydraulic Grade Line
(In)(ft)
Flow (Total Out)(cfs)
Elevation (Invert in 1)(ft)
Elevation (Rim)(ft)
Elevation (Ground)
(ft)
LabelID
5' MANHOLE0.8005,232.325,233.1714.605,231.035,237.235,237.23STM MH-0932
5' MANHOLE0.6005,229.395,230.2016.205,228.165,234.485,234.48STM MH-0834
5' MANHOLE0.6005,225.625,226.0617.705,224.605,231.685,231.68STM MH-0736
5' MANHOLE0.5005,218.735,219.1017.705,217.415,224.265,224.26STM MH-0637
5' MANHOLE0.6005,213.815,214.5027.005,210.625,218.195,218.19STM MH-0539
5' MANHOLE0.6005,208.995,209.5932.605,207.555,215.425,215.42STM MH-0441
5' MANHOLE0.6005,202.805,203.5138.305,200.915,209.655,209.65STM MH-0343
8' MANHOLE0.6005,201.115,201.3447.905,194.895,207.025,207.02STM MH-0244
8' MANHOLE0.0005,200.775,200.7747.905,192.475,206.185,206.18STM MH-1045
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 100 - Year
Profile Report
Engineering Profile - Profile - 1 (17-4088_StormCAD.stsw)
5,190.00
5,195.00
5,200.00
5,205.00
5,210.00
5,215.00
5,220.00
5,225.00
5,230.00
5,235.00
5,240.00
-0+50 0+00 0+50 1+00 1+50 2+00 2+50 3+00 3+50 4+00 4+50 5+00 5+50 6+00 6+50 7+00 7+50 8+00 8+50 9+00 9+50 10+00 10+50 11+00 11+50 12+00 12+50 13+00 13+50 14+00 14+50 15+00 15+50 16+00 16+50 17+00 17+50 18+00 18+50 19+00
Station (ft)
STM MH-09
Rim: 5,237.23 ftInvert: 5,230.58 ft
STM MH-02
Rim: 5,207.02 ftInvert: 5,193.43 ft
STM MH-03
Rim: 5,209.65 ftInvert: 5,200.34 ft
STM MH-04
Rim: 5,215.42 ftInvert: 5,206.68 ft
STM MH-05
Rim: 5,218.19 ftInvert: 5,210.13 ft
STM MH-06
Rim: 5,224.26 ftInvert: 5,217.21 ft
STM MH-07
Rim: 5,231.68 ftInvert: 5,223.81 ft
STM MH-08
Rim: 5,234.48 ftInvert: 5,227.71 ft
STM INLET-01
Rim: 5,201.47 ftInvert: 5,195.81 ft
PIPE - 7 (1): 297.1 ft @ 0.022 ft/ft
RCP
PIPE - 7: 297.0 ft @ 0.023 ft/ft
RCP
PIPE - 6: 112.1 ft @ 0.030 ft/ft
RCP
PIPE - 19: 110.0 ft @ 0.024 ft/ft
RCP
PIPE - 17: 343.1 ft @ 0.005 ft/ft RCP
PIPE - 3: 134.7 ft @
0.043 ft/ft
RCP
PIPE - 8 (1): 297.1 ft @ 0.021 ft/ft
RCP
PIPE - 8: 296.9 ft @ 0.010 ft/ft
RCP
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 100 - Year
Profile Report
Engineering Profile - Profile - 2 (17-4088_StormCAD.stsw)
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 100 - Year
Profile Report
Engineering Profile - Profile - 3 (17-4088_StormCAD.stsw)
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 100 - Year
Profile Report
Engineering Profile - Profile - 4 (17-4088_StormCAD.stsw)
Ele
va
tio
n (
ft)
PIPE - 28: 12.7 ft @ 0.020 ft/ft
RCP
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 100 - Year
Profile Report
Engineering Profile - Profile - 5 (17-4088_StormCAD.stsw)
Ele
va
tio
n (
ft)
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 100 - Year
Profile Report
Engineering Profile - Profile - 6 (17-4088_StormCAD.stsw)
Ele
va
tio
n (
ft)
PIPE - 26: 12.6 ft @ 0.020 ft/ft
RCP
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 100 - Year
Profile Report
Engineering Profile - Profile - 7 (17-4088_StormCAD.stsw)
Ele
va
tio
n (
ft)
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 100 - Year
Profile Report
Engineering Profile - Profile - 8 (17-4088_StormCAD.stsw)
Ele
va
tio
n (
ft)
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
Active Scenario: 100 - Year
Profile Report
Engineering Profile - Profile - 9 (17-4088_StormCAD.stsw)
Ele
va
tio
n (
ft)
PIP
E - 23: 12.7 ft @
0.030 ft/ft
RC
P
Page 1 of 127 Siemon Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666
1/24/2019
Bentley StormCAD CONNECT Edition[10.01.01.04]Bentley Systems, Inc. Haestad Methods Solution Center17-4088_StormCAD.stsw
1.24.2019 PAGE 17 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
APPENDIX C – Clogged Inlets and Street Capacity
Clogged Inlet Analysis
Street Section Capacity Checks
A1
A1
100 YR PONDING
WSEL=5202.25
5202.83 ROW
5201.67 FL
5202.68 FL
5202.00 FL
5202.96 ROW
5202.24 FL
5203.71 FL
5202.16 ROW
5201.00 FL
PROJECT NAME:
JOB NO.:
SHEET
SCALE:DRAWN: PA/PM:
DATE :
CIVIL ENGINEERING & SURVEYING
DP 7 CLOGGED INLET SECTION
WILLOWBEND - HOLLY STREET
DCS-17-4088 04/06/2018
LO TG 1"=50'
SCALE: 1" = 100'
ORIGINAL GRAPHIC SCALE
0 50 100
Project Description
Friction Method Manning Formula
Solve For Normal Depth
Input Data
Channel Slope 0.02000 ft/ft
Discharge 9.60 ft³/s
Section Definitions
Station (ft) Elevation (ft)
10+00 5202.83
10+50 5202.35
11+00 5202.13
11+18 5202.12
11+50 5202.18
12+00 5202.25
12+50 5202.48
Roughness Segment Definitions
Start Station & Elevation End Station & Elevation Roughness Coefficient
(10+00, 5202.83) (12+50, 5202.48) 0.030
Options
Current Roughness Weighted Method
Pavlovskii's Method
Open Channel Weighting Method Pavlovskii's Method
Closed Channel Weighting Method Pavlovskii's Method
Results
Normal Depth 0.13 ft
Elevation Range 5202.12 to 5202.83 ft
Flow Area 8.28 ft²
Wetted Perimeter 123.11 ft
Hydraulic Radius 0.07 ft
Top Width 123.11 ft
Worksheet for Inlet DP7 @ ROW
1/25/2019 10:50:59 AM
Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03]
27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of1Page
Results
Normal Depth 0.13 ft
Critical Depth 0.11 ft
Critical Slope 0.03325 ft/ft
Velocity 1.16 ft/s
Velocity Head 0.02 ft
Specific Energy 0.15 ft
Froude Number 0.79
Flow Type Subcritical
GVF Input Data
Downstream Depth 0.00 ft
Length 0.00 ft
Number Of Steps 0
GVF Output Data
Upstream Depth 0.00 ft
Profile Description
Profile Headloss 0.00 ft
Downstream Velocity Infinity ft/s
Upstream Velocity Infinity ft/s
Normal Depth 0.13 ft
Critical Depth 0.11 ft
Channel Slope 0.02000 ft/ft
Critical Slope 0.03325 ft/ft
Worksheet for Inlet DP7 @ ROW
1/25/2019 10:50:59 AM
Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03]
27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of2Page
Project Description
Friction Method Manning Formula
Solve For Normal Depth
Input Data
Channel Slope 0.02000 ft/ft
Normal Depth 0.13 ft
Discharge 9.60 ft³/s
Cross Section Image
Cross Section for Inlet DP7 @ ROW
1/25/2019 10:50:33 AM
Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03]
27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 1of1Page
29
S
W
S
S
A1
A1
5208.38
5211.00
5209.59
5208.62
5209.22
5207.42
5207.17 ROW
5206.07 ROW
5206.73 ROW
5206.14 FL
5205.33 FL
5206.20 FL
100 YR PONDING WSEL=5206.14
5206.51 FL
5206.08 FL
5206.94 FL
PROJECT NAME:
JOB NO.:
SHEET
SCALE:DRAWN: PA/PM:
DATE :
CIVIL ENGINEERING & SURVEYING
DP8 CLOGGED INLET SECTION
WILLOWBEND - HOLLY STREET
DCS-17-4088 04/06/2018
LO TG 1"=50'
SCALE: 1" = 100'
ORIGINAL GRAPHIC SCALE
0 50 100
Project Description
Friction Method Manning Formula
Solve For Normal Depth
Input Data
Channel Slope 0.02000 ft/ft
Discharge 5.10 ft³/s
Section Definitions
Station (ft) Elevation (ft)
10+50 5206.52
11+00 5206.20
11+50 5206.08
11+79 5206.06
12+00 5206.08
12+50 5206.21
13+00 5206.66
Roughness Segment Definitions
Start Station & Elevation End Station & Elevation Roughness Coefficient
(10+50, 5206.52) (13+00, 5206.66) 0.030
Options
Current Roughness Weighted Method
Pavlovskii's Method
Open Channel Weighting Method Pavlovskii's Method
Closed Channel Weighting Method Pavlovskii's Method
Results
Normal Depth 0.08 ft
Elevation Range 5206.06 to 5206.66 ft
Flow Area 5.22 ft²
Wetted Perimeter 100.33 ft
Hydraulic Radius 0.05 ft
Top Width 100.33 ft
Worksheet for Inlet DP8 @ ROW
1/25/2019 10:51:42 AM
Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03]
27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of1Page
Results
Normal Depth 0.08 ft
Critical Depth 0.07 ft
Critical Slope 0.03664 ft/ft
Velocity 0.98 ft/s
Velocity Head 0.01 ft
Specific Energy 0.10 ft
Froude Number 0.75
Flow Type Subcritical
GVF Input Data
Downstream Depth 0.00 ft
Length 0.00 ft
Number Of Steps 0
GVF Output Data
Upstream Depth 0.00 ft
Profile Description
Profile Headloss 0.00 ft
Downstream Velocity Infinity ft/s
Upstream Velocity Infinity ft/s
Normal Depth 0.08 ft
Critical Depth 0.07 ft
Channel Slope 0.02000 ft/ft
Critical Slope 0.03664 ft/ft
Worksheet for Inlet DP8 @ ROW
1/25/2019 10:51:42 AM
Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03]
27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of2Page
Project Description
Friction Method Manning Formula
Solve For Normal Depth
Input Data
Channel Slope 0.02000 ft/ft
Normal Depth 0.08 ft
Discharge 5.10 ft³/s
Cross Section Image
Cross Section for Inlet DP8 @ ROW
1/25/2019 10:51:26 AM
Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03]
27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 1of1Page
29
STS
A1
A1
5207.12 ROW
5206.09 ROW
5206.96 ROW
5206.14 FL
5205.11 FL
5205.98 FL
100 YR PONDING WSEL=5206.15
5206.91 FL
5205.90 FL
5206.75 FL
PROJECT NAME:
JOB NO.:
SHEET
SCALE:DRAWN: PA/PM:
DATE :
CIVIL ENGINEERING & SURVEYING
DP9 CLOGGED INLET SECTION
WILLOWBEND - HOLLY STREET
DCS-17-4088 04/06/2018
LO TG 1"=50'
SCALE: 1" = 100'
ORIGINAL GRAPHIC SCALE
0 50 100
Project Description
Friction Method Manning Formula
Solve For Normal Depth
Input Data
Channel Slope 0.02000 ft/ft
Discharge 2.40 ft³/s
Section Definitions
Station (ft) Elevation (ft)
10+50 5206.59
11+00 5206.25
11+36 5206.12
11+64 5206.09
12+00 5206.14
12+50 5206.38
13+00 5206.75
Roughness Segment Definitions
Start Station & Elevation End Station & Elevation Roughness Coefficient
(10+50, 5206.59) (13+00, 5206.75) 0.030
Options
Current Roughness Weighted Method
Pavlovskii's Method
Open Channel Weighting Method Pavlovskii's Method
Closed Channel Weighting Method Pavlovskii's Method
Results
Normal Depth 0.06 ft
Elevation Range 5206.09 to 5206.75 ft
Flow Area 2.98 ft²
Wetted Perimeter 76.58 ft
Hydraulic Radius 0.04 ft
Top Width 76.58 ft
Worksheet for Inlet DP9 @ ROW
1/25/2019 10:52:38 AM
Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03]
27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of1Page
Results
Normal Depth 0.06 ft
Critical Depth 0.06 ft
Critical Slope 0.04109 ft/ft
Velocity 0.81 ft/s
Velocity Head 0.01 ft
Specific Energy 0.07 ft
Froude Number 0.72
Flow Type Subcritical
GVF Input Data
Downstream Depth 0.00 ft
Length 0.00 ft
Number Of Steps 0
GVF Output Data
Upstream Depth 0.00 ft
Profile Description
Profile Headloss 0.00 ft
Downstream Velocity Infinity ft/s
Upstream Velocity Infinity ft/s
Normal Depth 0.06 ft
Critical Depth 0.06 ft
Channel Slope 0.02000 ft/ft
Critical Slope 0.04109 ft/ft
Worksheet for Inlet DP9 @ ROW
1/25/2019 10:52:38 AM
Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03]
27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 2of2Page
Project Description
Friction Method Manning Formula
Solve For Normal Depth
Input Data
Channel Slope 0.02000 ft/ft
Normal Depth 0.06 ft
Discharge 2.40 ft³/s
Cross Section Image
Cross Section for Inlet DP9 @ ROW
1/25/2019 10:52:08 AM
Bentley Systems, Inc. Haestad Methods Solution CenterBentley FlowMaster V8i (SELECTseries 1) [08.11.01.03]
27 Siemons Company Drive Suite 200 W Watertown, CT 06795 USA +1-203-755-1666 1of1Page
1.24.2019 PAGE 18 990 South Broadway #230 Denver, CO 80209 P 303.561.3333
APPENDIX D – Maps
Developed Basin Map
TR
AC
T E
TR
AC
T D
2
1 3
4
5
6
10
1
2 3
4
5
6
7
8
9
11
12
13
14
22
23
11
12
13
14
15
16
17
18
19
20
21
24
25
26
27
28
29
30
31
32
10
S
S
S
S
S
S
S
S
SS
S
S
S S S S S S
S S S S S S
S
S S S S S
S S S S S
S
S
W
W
W
W
W
W
WW
W
W
W
W
W W W W W W
W
W W W W W
W W W W W
W W W W W W
W
W
E
E
E
E
E E E
E
E
E
X X XXXX
X
X X X X X X X X X
X X
X
XX
X X X X
U
U
ST
ST
ST
ST
ST
ST
ST
B
R
TR
AC
T P
TR
AC
T N
TR
AC
T R
TR
AC
T X
TR
AC
T X
TR
AC
T E
TR
AC
T R
TR
AC
T Q
TR
AC
T X
TR
AC
T X
TRACT E
T
R
A
C
T
U
T
R
A
C
T
Z
TR
AC
T Q
30
13
13
28
28
30
29
29
29
29
26
26
15
G
R
A
P
E
S
T
.
E. 148T
H A
VE
.
HUDSON ST.
GR
AP
E S
T.
HUDSON WAY
HUDSON ST.
S
I
G
N
A
L
D
I
T
C
H
P
K
W
Y
.
HUDSON ST.
E. 146T
H A
VE
.
HOLLY ST.
HOLLY ST.
HOLLY ST.
7
8
15
14
19
22
9
20
10
11
2
1
3
4
12
13
14
15
16
17
18
1 2
3
4
5
6
8
9
1
7
9
10
11
12
13
16
17
18
20
21
23
9
1
9
7
10
8
9
11
14
12
13
12
3
54
7
6
8
12
13
14
15
23
4
5
6
5
8
6
7
9 10
11
18
16
19
17
11
10
1
2
3
4
5
6
7
ST
ST
ST
ST
ST
ST
ST
ST
ST
A-1
1.97
AC.
0.79
0.86
A-3
0.22
AC.
0.72
0.83
A-4
1.38
AC.
0.77
0.85
A-6
1.02
AC.
0.72
0.83
A-2
0.22
AC.
0.72
0.83
A-5
1.04
AC.
0.72
0.82
A-7
1.27
AC.
0.77
0.85
A-8
0.92
AC.
0.76
0.84
A-9
0.33
AC.
0.73
0.83
STM INLET-01
STM MH-02
STM MH-03
STM INLET-02
STM MH-04
STM INLET-03
STM MH-05
STM INLET-04
STM MH-06
STM MH-07
STM INLET-05
STM MH-08
STM INLET-06
STM MH-09
STM INLET-07
STM MH-10
STM INLET-00
STM INLET-0.1
5
2
4
5
5
2
2
5
5
2
3
0
5
2
1
5
5
2
0
5
TH
O
M
A
S
C .
J
A
N
S
E
N
PR
O
F
E
S
S
I
O
NAL
E
N
G
I
N
E
E
R
C
O
L
O
R
A
D
O L
IC
E
N
S
E
D
0 75 150 300
SCALE: 1" = 150'
ORIGINAL GRAPHIC SCALE
CAUTION: IF THIS SHEET IS NOT 24"x36" IT IS A REDUCED PRINT
TH
ES
E D
RA
WIN
GS
A
ND
S
PE
CIF
IC
AT
IO
NS
A
RE
T
HE
P
RO
PE
RT
Y A
ND
C
OP
YR
IG
HT
O
F W
AR
E M
ALC
OM
B A
ND
S
HA
LL N
OT
B
E U
SE
D O
N A
NY
O
TH
ER
W
OR
K E
XC
EP
T B
Y A
GR
EE
ME
NT
W
IT
H W
AR
E M
ALC
OM
B. W
RIT
TE
N D
IM
EN
SIO
NS
S
HA
LL T
AK
E P
RE
CE
DE
NC
E O
VE
R S
CA
LE
D D
IM
EN
SIO
NS
A
ND
S
HA
LL B
E V
ER
IF
IE
D O
N T
HE
JO
B S
IT
E. A
NY
D
IS
CR
EP
AN
CY
S
HA
LL B
E B
RO
UG
HT
T
O T
HE
N
OT
IC
E O
F W
AR
E M
ALC
OM
B P
RIO
R T
O T
HE
C
OM
ME
NC
EM
EN
T O
F A
NY
W
OR
K.
FOR AND ON BEHALF
OF WARE MALCOMB
SHEET
PA / PM:
JOB NO.:
DRAWN BY:
RE
MA
RK
SD
AT
EN
O.
Sheet of
DATE:
suite 230
990 south broadw
ay
denver, co 80209
p 303.561.3333
warem
alcom
b.com
C
I V
I L E
N
G
I N
E
E
R
I N
G
&
S
U
R
V
E
Y
I N
G
WILLO
W B
EN
D H
OLLY
S
TR
EE
T
DR
AIN
AG
E R
EP
OR
T
17-4088
TG
LMO
04/06/2018
DR01
01 01
LEGEND
DESIGN POINT
PROPOSED FLOW DIRECTION
STREET SLOPE
EXISTING GRADE CONTOUR
A = DEVELOPED BASIN DESIGNATION
B = BASIN AREA (ACRES)
C = 5 YEAR COMPOSITE RUNOFF
COEFFICIENT
D = 100 YEAR COMPOSITE RUNOFF
5250
PROPOSED PROPERTY LINE
6.00%
HIGH POINT
LOW POINT
PROPOSED STORM SEWER W/ F.E.S.
PROPOSED TYPE 13 (SPECIAL) INLET
EXISTING TYPE 13 (SPECIAL) INLET
EXISTING CULVERT
PROPOSED GRADE CONTOUR
5250
CATCHMENT BOUNDARY
PROPOSED MAJOR BASIN BOUNDARY
A
B
AC.
C
D
H.P.
L.P.
BASIN BOUNDARY FROM PREVIOUS
STUDY
PROPOSED BASIN BOUNDARY