FINANCE, RISK AND BUSINESS PLANNING Supply Management City of Vancouver, Finance, Risk and Business Planning Supply Management 453 West 12th Avenue Vancouver, British Columbia V5Y 1V4 Canada tel: 604.873.7263 fax: 604.873.7057 website: vancouver.ca February 22, 2016 INVITATION TO TENDER (“ITT”) NO. PS20152044 CONSTRUCTION SERVICES FOR VPD RENOVATIONS – PHASE 1 ADDENDUM No. 4 RE: VARIOUS ITEMS: See attached “Addendum 4” document dated February 22, 2016 (24 pages total) All other conditions and specifications remain unchanged. This addendum must be completed, and attached to your Tender form. If you have already submitted your Tender, this addendum shall be submitted to the Purchasing Services Office, City of Vancouver, 453 West 12 th Avenue, Vancouver, British Columbia, Canada, V5Y 1V4, (Courier Delivery and Drop off is at the Information Desk, Main Floor Rotunda of the same address), prior to the Closing Time: 3:00 p.m. Local Vancouver, BC Time, in an envelope clearly marked “Addendum No. 4 to ITT No. PS20152044 CONSTRUCTION SERVICES FOR VPD RENOVATIONS – PHASE 1” before the closing time of 3:00 p.m., March 1, 2016. _____________________________________ NAME OF VENDOR ________________________________________ SIGNATURE OF AUTHORIZED SIGNATORY DATE Philip Lai, P. Log, SCMP Buyer II

FINANCE, RISK AND BUSINESS PLANNING February …bids.vancouver.ca/bidopp/ITT/documents/PS20152044-ADD4.pdftransmission ratings when laboratory tested to ASTM E90. ... 108, 6871 Elmbridge

Embed Size (px)

Citation preview

FINANCE, RISK AND BUSINESS PLANNINGSupply Management

City of Vancouver, Finance, Risk and Business Planning Supply Management 453 West 12th Avenue Vancouver, British Columbia V5Y 1V4 Canada tel: 604.873.7263 fax: 604.873.7057 website: vancouver.ca

February 22, 2016

INVITATION TO TENDER (“ITT”) NO. PS20152044

CONSTRUCTION SERVICES FOR VPD RENOVATIONS – PHASE 1

ADDENDUM No. 4

RE: VARIOUS ITEMS:

See attached “Addendum 4” document dated February 22, 2016 (24 pages total) All other conditions and specifications remain unchanged. This addendum must be completed, and attached to your Tender form. If you have already submitted your Tender, this addendum shall be submitted to the Purchasing Services Office, City of Vancouver, 453 West 12th Avenue, Vancouver, British Columbia, Canada, V5Y 1V4, (Courier Delivery and Drop off is at the Information Desk, Main Floor Rotunda of the same address), prior to the Closing Time: 3:00 p.m. Local Vancouver, BC Time, in an envelope clearly marked “Addendum No. 4 to ITT No. PS20152044 CONSTRUCTION SERVICES FOR VPD RENOVATIONS – PHASE 1” before the closing time of 3:00 p.m., March 1, 2016.

_____________________________________ NAME OF VENDOR

________________________________________

SIGNATURE OF AUTHORIZED SIGNATORY

DATE

Philip Lai, P. Log, SCMP Buyer II

PD Group Interior Design Ltd. T: 604.605.0900 [email protected] 2857 West 8th Avenue, Vancouver, BC V6K 2B8 F: 604.605.0990 www.pdgroup.ca

PROJECT NAME: VPD – 3585 GRAVELEY STREET AND DATE: FEBRUARY 22, 2016 236 EAST CORDOVA STREET PROJECT NUMBER: PS20152044 ADDENDUM NO: 4 TO: CITY OF VANCOUVER                         FROM: PD GROUP INTERIOR DESIGN REAL ESTATE AND FACILITIES MANAGEMENT

This Addendum is issued prior to the Tender Due Date to revise the Tender/Contract Documents, and as such is part of those documents; the value of all items shall be included in the Tender. After Acceptance of Tender, claims for cost will not be considered by reason of failure by the Bidder to have read the addenda.

Addendum issued in regard to:

1. Revised plan showing wall type 3.0 and wall type 3.1 attached ID – SK-1

2. Specification for PS 350 as wall type 3.0 attached.

a. 3.0 DEMOUNTABLE PARTITION - SLAB U/S OF T-BAR PS 350 demountable wall with insulation in wall cavity, vinyl wallboard on each side, acoustic caulking top and bottom.

3. Specification for PS 350 Executive Series as wall type 3.1 attached with integral whiteboard and marker tray.

a. 3.1 DEMOUNTABLE PARTITION - SLAB U/S OF T-BAR PS 350 demountable wall executive series with insulation in wall cavity, vinyl wallboard on each side, whiteboard material provided as shown on plan with marker tray. Acoustic caulking top and bottom.

ADDENDUM 4

ID-SK-1

Anna
Polygon

SPECIFICATION: PS 350 GRAVITY LOCK MOVABLE WALL SYSTEM

DEMOUNTABLE AND STEEL STUD AND

GYPSUM BOARD PARTITIONS

1.0 GENERAL

1.1 RELATED WORK SPECIFIED IN OTHER SECTIONS

1.2 DESCRIPTION OF SYSTEM

.1 GENERAL: Floor to ceiling height movable partition system consisting of pre-finished gypsum board panels applied to both sides of steel stud framing including door and window frames.

.2 CONSTITUENT PARTS

.1 Tree studs, base track and top track.

.2 Tree stud brackets.

.3 Pre-finished gypsum board panels.

.4 Retainer clips and fasteners.

.5 Acoustical insulation where required.

.6 Sound/light seals.

.7 Glazing frames with glazing beads.

.8 Trim components.

.9 Base

.10 Monolithic corners and surface mounted terminal partition end caps.

.11 Other miscellaneous components and accessories.

.12 Cable Management Modules [ CSA approved ] as required.

.13 Pivot door and frame complete with pivot hardware as required.

.3 ERECTION: Non-Progressive Butt Joint

.4 ADJUSTABILITY: Partition System shall be capable of adjusting to irregularities in level of floor and ceiling surface up to 25mm in 3m.

.5 DEMOUNTABILITY: Partition System shall be fully demountable and re-locatable with near-total salvage-ability of all components.

.6 PARTITION SYSTEM DIMENSIONS

.1 Panel module: (4'-0") 1219mm.

.2 Total thickness of standard partition: (3 1/2") 89mm.

.3 Total thickness of acoustically treated partitions: as standard partition.

.4 Height: As indicated on drawing.

WALL TYPE 3.0

2

.7 APPEARANCE

.1 Joints: Hairline Butt joint resulting in a flush vertical plane throughout.

.2 Panels: Factory pre-finished with a decorative vinyl film.

.3 Outside corners: Monolithic Radius extruded aluminium semi flush with factory pre-finished decorative vinyl film.

.4 Inside Corners: PVC Milcore type panel edge trim with factory pre-finished decorative vinyl film in matching panel finish.

.5 Wall Starts: PVC Milcore type panel edge trim with factory pre-finished decorative vinyl film in matching panel finish.

.6 Other trim: All horizontal ceiling, door and window frame trim standard PVC colour as per finish schedule.

.7 All trims on Door and Glazing frames mitred to form 90 degrees

.8 COMPATIBILITY: Partition System shall accommodate the following: .1 Concealed electrical wiring. .2 Concealed thermostat wiring and tubing. .3 Wall mounted thermostats. .4 Independent cable management modules. .5 Window and door frames.

1.3 ACCEPTABLE MANUFACTURERS

.1 PS 350 Gravity Lock Movable Partition System as the standard of quality and

performance required. 1.4 PERFORMANCE REQUIREMENTS

.1 STRUCTURAL: Partition System shall be structurally stable and vibration-free when subjected to impact loads of type occurring under normal use.

.2 FIRE PROTECTION:

.a Major components of the system shall be non combustible.

.b Exposed panel surfaces shall meet the following fire hazard classification requirements:

Flame Spread max. 25 Fuel Contributed max. 35 Smoke Development max. 50

.3 ACOUSTICAL: Partition System shall provide the following minimum sound transmission ratings when laboratory tested to ASTM E90. .a Standard partition STC 35 .b Acoustically treated STC 46

3

1.5 SUBMITTALS

.1 PRODUCT DATA: Submit product data in accordance with Section 01300. Data shall include plans, elevations and sections of panels, connection installation procedures.

.2 SAMPLES: Submit duplicated 200mmx300mm samples of panel finishes and textures

and 300mm long samples of each colour trim. .3 MAINTENANCE DATA: Submit complete maintenance data for Partition System

including instructions for dismantling and reassembling Partition System components.

1.6 SOURCE OF SUPPLY

.1 The Partition System shall be part of a single, established, pre-designed and manufactured demountable Partition System provided by a single supplier. To insure continuity of colours, panel and component trim vinyl origination is to be from the same production run.

1.7 DELIVERY, STORAGE AND HANDLING

.1 Prevent damage to gypsum board panels during delivery, storage and handling. .2 Store gypsum board panels flat, indoors. Protect carpet and other floor finishes from

damage and soiling. 1.8 SITE CONDITIONS

.1 Protection: Protect floor, ceiling and wall finishes from damage and soiling resulting from work of this section.

1.9 CO-ORDINATION

.1 Co-ordinate erection of Partition System with installation of mechanical, electrical and telephone services.

1.10 SEQUENCING AND SCHEDULING

.1 Install Partition System after carpet has been installed.

4

2.0 PRODUCTS 2.1 PRODUCT MANUFACTURER

CALGARY 1043 26 Street N.E.

Calgary, AB, Canada T2A 6K8

Phone 403-272-7600 Fax 403-272-6490

EDMONTON 1220 70 Avenue N.W.

Edmonton, AB, Canada T6P 1P5

Phone 780-465-9327 Fax 780-465-2195

VANCOUVER 108, 6871 Elmbridge Way Richmond, BC, Canada

V7C 5A4 Phone 604-270-8926

Fax 604-270-2911

Web Site: www.partitions.com E-Mail: [email protected]

2.2 COMPONENTS

.1 TOP TRACK: 26 ga. steel with hemmed legs designed to accept independent snap-on and off partition finish trim from either wall side.

.2 TREE STUD: Hot dipped galvanized steel having G-60 wiped zinc coating to ASTM

525. Rolled formed from ASTM A-446 Grade A, .053mm base metal. Hemmed flange depth of 32mm minimum.

.3 VINYL-FACED GYPSUM BOARD: to CSA A82.27-M-1977, standard 12.7 mm thick.

Vinyl film to be factory bonded to face side with approved adhesive. Finished board product shall meet the standards for surface burning characteristics specified under fire protection authority.

.4 BRACKETS: PS-350 Tree Stud Brackets. .5 ACOUSTICAL INSULATION: Type recommended by partition manufacturer to

achieve specified STC rating. .6 RETAINER CLIPS, FASTENERS AND CONNECTORS: As recommended by

Partition manufacturer. .7 SOUND/LIGHT SEAL: Closed cell, inorganic permanently elastic, sponge type

stripping with adhesive one side, minimum 19mmx3mm thick. .8 DOOR FRAMES: Aluminium Association Alloy 6063-T5, .080 minimum thickness

extruded aluminium frames and PVC stops. Complete with pivot door hardware. .9 GLAZING FRAMES: Aluminium Association Alloy 6063-T5, .080 minimum thickness,

extruded aluminium frames, PVC glass stops and glazing beads designed to accept 6mm glass.

10. PIVOT DOORS: Partition Systems Pivot Door 3' x full height, Solid core: Flat Cut Red

Oak, 3 coats of clear lacquer finish. .11 BATTEN TRIM: Snap-on PVC type as per finish schedule.

5

.12 EDGE TRIM: Milcore type PVC friction to fit to all inside corners with factory applied vinyl.

.13 PARTITION BASE: Snap-on PVC type. Colour as per finish schedule. .14 CEILING AND BASE OUTSIDE CORNERS: Snap-on PVC type 300x300mm factory

manufactured. .15 MONOLITHIC CORNERS: Extruded aluminium with factory applied vinyl film. .16 MISCELLANEOUS ACCESSORIES: Miscellaneous trim, rail caps, fasteners, clips

and other accessories for installation as recommended by partition manufacturer. .17 FACTORY FABRICATED CABLE MANAGEMENT MODULE: Unitized electrical

/computer wall module, factory built as indicated on drawings. .18 BASE TRACK: 2 1/2 Wide x 2" deep.

2.3 FINISHES

.1 VINYL FACED PANELS: Colours and textures as per finish schedule. .2 INSIDE CORNER PVC EDGE TRIM: Factory applied vinyl to match adjacent wall

finish. .3 MONOLITHIC CORNERS: Factory applied vinyl to match adjacent wall finish. .4 PVC CEILING TRIM: Standard 1 3/8” PVC covered with Factory Applied Vinyl .5 PVC BASE TRIM: Standard PVC colour as per finish schedule. .6 WALL TERMINATION END CAPS: Semi-Flush aluminium with factory applied vinyl to

match adjacent wall finish. .7 ALUMINUM DOOR AND WINDOW FRAMES: As per finish schedule. .8 PVC DOOR & WINDOW FRAME TRIMS: Standard PVC colour as per finish

schedule. .9 Glass Stops: To suit 6mm glass. Colour as per finish schedule.

6

3.0 EXECUTION 3.1 SITE MEASUREMENTS

.1 Take site measurements of existing building to confirm dimensions prior to starting work.

3.2 INSTALLATION

.1 Installed by manufacturer’s approved applicator.

.2 Install partitions and all component parts in accordance with the manufacturer's instructions.

.3 Erect Partitions, plumb, square and level: Accurately fit and fasten to abutting

surfaces. Adjust to irregularities in floor levels to ensure level installation. .4 Position Partition Ceiling Track where cable management units are located 3/4” OFF

CENTRE FROM CEILING GRID SYSTEM to allow a clear vertical access for electrical between ceiling space and partition cavity unless otherwise indicated.

.5 Install cable management modules in conjunction with partition studding at locations

indicated on drawing. .6 At carpeted floors use, to extent possible, a hooked fastener tape that rigidly secures

partition without damaging or defacing carpet. Fasten base track directly to substrate, through carpet, at door openings and other locations where additional rigidity is required.

.7 At suspended ceilings use fasteners as required that rigidly support partition without

damaging or defacing ceiling panels or grid system members. .8 Position Tree studs vertically in base and top tracks at 600mm on centre maximum.

Do not break module at door and window openings. .9 Permanently fix each stud in place using 5/8" fasteners to restrain from horizontal

movement prior to gypsum board attachment: .10 Install 6 carrying brackets per tree stud. Ensure all brackets are fully engaged into tree

stud slots. .11 Install continuous closed cell foam tape at perimeter of each partition including junction

of partition with ceilings, other partitions, existing walls, window mullions, and other appurtenances. Included is a seal at carpeted floors.

.12 Ensure movement free contact is achieved between studs and back of panel by fully

engaging all finger clip attachments onto the carrying brackets. .13 Cut and fit panels accurately to fit neatly where panels abut to existing walls, window

mullions or other appurtenances.

7

.14 Install concealed panel clip fasteners in accordance with manufacturer’s instructions. Panels sustaining core fractures that telegraph clip location as in bulges or blisters onto the panel face will be rejected.

.15 Butt panels together to achieve a continuous moderate edge contact. Attach panels

securely against studs ensuring a flush panel surface along the hairline joint. .16 Fasten door and glazing frames securely to studs. If necessary, reinforce doorjamb

framing to insure structural stability. .17 Install monolithic corners as per manufactured instruction. Use of adhesives will not be

allowed. .18 Install base at all floor junctions.

3.3 INSTALLATION OF ACOUSTICALLY TREATED PARTITIONS

.1 Install acoustically treated partitions to conform to tested assembly. .2 Fill stud cavities completely with 2" acoustical batt insulation; recommended for

movable partitions; including around openings, in corners, and in studs adjacent to door and glazing frames.

.3 Ensure that closed cell foam tape at partition perimeter is continuous and under

compression when installed. Ensure that all potential sound transmission leaks are completely sealed.

.4 If Partition System design or installation has been modified from that of the tested

assembly, ensure that such modifications do not compromise the acoustical performance characteristics of the Partition System. Such modifications shall be subject to the consultant's approval.

3.4 ADJUSTMENT

.1 Correct misalignment of expose trim.

3.5 PATCHING AND CLEANING

.1 Remove and replace panels and other components which are: .a Damaged, .b Improperly installed, or .c Soiled Beyond satisfactory cleaning.

.2 Clean soiled panel and trim surfaces after installation. .3 Clean all floor, ceiling and wall surfaces soiled as a result of work of this Section.

END OF SECTION

Section 10 22 00 Moveable Partitions

Page 1

1. General

1.1. RELATED SECTIONS

.1 Doors Section 08 30 00.

.2 Door Hardware Section 08 71 00.

.3 Glazing Section 08 80 00.

.4 Gypsum Board Section 09 25 00.

.5 Acoustical Ceilings Section 09 51 00.

.6 Carpet Section 09 68 00.

.7 Open office Furniture Section 12 61 00.

.8 Electrical Section 16 40 00.

1.2. REFERENCE DOCUMENTS

.1 Americans with Disabilities Act (ADA).

.2 ANSI/BIFMA x-5.6-2003, Panel Systems.

.3 ASTM B221: Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wire, Profiles, and Tubes.

.4 ASTM E84-05, Standard Test Method for surface burning characteristics of building materials.

.5 ASTM E72, Standard Test Method of conducting strength tests of panels for building construction.

.6 ASTM E90-04, Standard Test Method for laboratory measurement of Airborne Sound Transmission loss of building partitions and elements.

.7 ASTM E413: Standard Classification for Rating Sound Insulation.

.8 AWI: Quality Standards

.9 CSA STD C22.1: Canadian Electrical Code, Part 1.

.10 CSA STD C22.2: Canadian Electrical Code, Part 2.

.11 NFPA 70: National Electrical Code.

.12 Underwriters Laboratories, UL183 Manufactured wiring systems.

WALL TYPE 3.1

Section 10 22 00 Moveable Partitions

Page 2 1.3. SYSTEM DESCRIPTION

.1 Unitized, Demountable Movable Wall Partition System: .1 A Unitized, movable partition system for interior use, designed to permit

replacement of finishes, relocation of wall sections, and reuse of all parts. .2 Non-progressive, allowing for removal and reinstallation of wall sections

from either side of partition and at any point in the panel field, without disturbance of adjacent panels.

.3 Erected and disassembled in a manner preventing damage to adjacent building surfaces and elements, including floors (tile or carpet), walls, ceilings, columns and window mullions.

.4 Permits two, three, and four-way panel connections using a common post connector system.

.5 Interchangeable finished surfaces can be rearranged in any desired combination within a given wall space. Dissimilar finishes and arrangements are possible on each side of the wall system.

.6 Glazing system capable of being configured with either single glazed framing or double glazed. Single glazing configuration to accept 4, 6, or 10mm Tempered glass, Double glazing to accept 4 and/or 6mm tempered glass.

.7 Partition system shall be nominally 4-1/4” (108mm) thick and provide a clear and accessible 3” (76mm) wall cavity.

.8 Partition system capable of accommodating floor and ceiling height variations of 3”. Frame will permit the on site addition or removal of vertical frame extensions for reconfiguration to a location with an alternate ceiling height, in a non-seismic zone.

.9 All vertical frame joints to provide concealed – integral slotting for the attachment of system furniture mounting adapters.

.10 Partition system shall provide a continuous, full height sound and light seal at the panel to panel connection.

.11 Ceiling track to be a one piece continuous aluminum extrusion, complete with resilient light and sound seals recessed from the panel face. Ceiling track is to be attached to underside of suspended ceiling without the use of destructive fasteners.

.12 Floor attachment to be achieved without mechanical fastening (in non-seismic zones).

.13 All glazed sections shall be factory glazed. Partition system to be capable of site installation of glazing.

.14 Door units to be interchangeable with solid or glazed units of like size.

.15 Solid doors to be 1-3/4” (45mm) thick, architectural quality solid core wood.

.16 Partition system to be capable of being dismantled into component parts for ease of distribution, installation and storage, or moved as assembled units.

Section 10 22 00 Moveable Partitions

Page 3

.17 Partition system shall accommodate field installed power and communication wiring without damage to the wall structure.

.2 Performance Requirements: .1 Acoustic attenuation: Solid full height wall sections to have an STC

rating of 46 within the speech privacy range when tested in accordance with ASTM E90 Sound Transmission Test by Two-Room Method and classified in accordance with ASTM E413.

.2 Vertical Load capacity: Comply with ANSI/BIFMA X5.6. Functional load capacity of 300 lbs (136 Kg) per panel to a maximum of 900 lbs (409 Kg) per 12’-0” (3.66 m) wall run. And a Proof load of 400 lbs (182 Kg per panel to a maximum of 1200 lbs (545 Kg) per 12’-0” wall run.

.3 Flame spread rating: Able to achieve up to a Class A rating (less than 25 flame spread rating), when tested in accordance with ASTM E84.

.4 Transverse Load capacity: partition shall be able to sustain a 5 psf (1200 Pa) minimum transverse loading, with panel deflection no greater than 1/120th

of the vertical span when tested in accordance with ASTM E72.

1.4. SUBMITTALS

.1 Submit under the provisions of Section 01 34 00.

.2 Shop drawings: Confirm panel layouts shown on the plan and elevation.

.3 Samples: Submit 8-1/2” x 11” (216mm x 279mm) panel facing, finished and complete with trim colors.

.4 Provide manufacturer’s installation instructions.

1.5. QUALITY ASSURANCE

.1 Installation will be performed by manufacturer’s personnel or by others authorized by partition system manufacturer.

.2 Factory-installed electrical components to meet or exceed CAN/CSA-C22.2

and certified under CSA/NRTL/C.

.3 Site measurements are to be taken by Supplier, where possible, prior to preparation of shop drawings and fabrication to ensure proper fitting of the work.

Section 10 22 00 Moveable Partitions

Page 4

.4 Supplier shall train the user’s maintenance personnel and supply special tools which are required for the maintenance and relocation of the partition system.

1.6. DELIVERY, STORAGE AND HANDLING

.1 Do not begin delivery or installation until site conditions provide protection from weather, and environmental conditions within the building are approximately equivalent to those that will exist when occupied.

1.7. WARRANTY

.1 Provide manufacturer’s warranty against defects in material and workmanship for a period of Ten (10) years, excluding fabrics and other finish materials that shall be guaranteed for 3 years.

1.8. ENVIRONMENTAL QUALIFICATIONS

.1 The system shall contribute to LEED – Commercial Interior’s certification.

.2 Ability to separate and recycle finished product at recycling facilities located in or near major cities in North America.

.3 The system should not use any PVC components

2. Products 2.1. MANUFACTURER

.1 Contract documents are based on the Executive Series as manufactured by: PSL Partition Systems Ltd. 1647 – 70 Avenue Edmonton, Alberta CANADA T6P 1N5 Telephone: (780)465-0001 (800)567-2454 Fax: (780)466-7535 E-mail: [email protected] Website: www.partitions.com

Section 10 22 00 Moveable Partitions

Page 5

.2 Substitutions: Products by other manufacturers require prior approval under provisions of Section 01 60 00.

2.2. MATERIALS

.1 Aluminum extrusions to be ASTM B221 aluminum alloy suited to the application.

.2 Particle board: particle board to maintain flatness of 1/8” (3mm) maximum deviation, 5/8” (16mm) thick.

.3 Glazing: Shall be Tempered or laminated

.4 Sound/light seals: Inner ceiling track: Self adhesive, closed cell, inorganic, permanently elastic, sponge type stipping, Grey. Outer ceiling and Base track: Flexible Thermoplastic sealing strip, black.

.5 Acoustical insulation: 2” (51mm) thick, 1.0 lb/cu.ft. (18 Kg/cu.m) density glass fibre batt, unfaced, formaldehyde free.

2.3. FABRICATION

.1 Panels .1 Aluminum extrusions fastened together forming a rigid frame.

.2 One set of two (2) adjustable levelling legs with 3” of adjustment

per unitized frame.

.3 Base track, pre-assembled with frame and attached to levelling legs

.4 Base track, comes with flexible thermoplastic sealing strip attached

.5 Sound attenuation insulation in panel cavities

.2 Ceiling track .1 Continuous extruded aluminum designed to accept non-marring

ceiling clip attachment.

Section 10 22 00 Moveable Partitions

Page 6

.2 Complete with self adhesive, closed cell, inorganic, permanently elastic, sponge type stripping, inner seals and flexible thermoplastic outer sealing strips attached.

.3 Wall starts

.1 Extruded aluminum channel designed to allow for wall length and surface variations.

.2 Compression member allows for the channel to be held tight to the existing wall without the use of mechanical fastening.

.3 Complete with self adhesive, closed cell, inorganic, permanently elastic, sponge type stripping, inner seals and flexible thermoplastic outer sealing strips attached.

.4 Frame connectors

.1 Interlocking metal clips connect the unitized frames to one another while maintaining the proper spacing.

.5 Door and Window Frames

.1 Factory-fabricated extruded aluminum units assembled for site installation.

.2 Clear anodized or powder coated in standard stocked color.

.3 Glazing stops to be systems aluminum snap-lock either single glazed or double glazed type.

.4 Glazing bead to be extruded flexible plastic of proper type for glazing configuration and glass thickness.

.5 Door frames to include continuous resilient gasket to seal door against frame.

.6 Door frames are pre-machined for door hardware

.6 Solid face panels .1 Low pressure laminate, High pressure laminate or veneer faced

particle board. .2 Fabric or vinyl covered cork faced fiberboard panel. .3 Dry erase panels, 4mm thick back painted glass mounted onto ½”

(13mm) MDf.

.7 Solid core Doors. .1 Core: Low density particle board .2 Stiles: Solid finger jointed pine lumber, clear grade, 2” (50mm)

thick both sides, blocking added if design requires. .3 Rails: solid finger jointed pine lumber, clear grade, 2-3/8” (60mm)

thick top and bottom. .4 Sub faces: ¼” (6mm) high density overlay for maximum durability

and freedom from telegraphing .5 Edges: 3/8” (10mm) solid wood edge matching face veneer

Anna
Polygon

Section 10 22 00 Moveable Partitions

Page 7

.6 Surface: premium face veneers or plastic laminates applied.

.8 Electrical and communication services .1 Panels shall be fully accessible from either side to allow for direct

access to clear 3” (76mm) interior cavity space. .2 Panel system to allow for wire management distribution through

out panel cavity. .3 Cut outs in horizontal framing members to allow for easy wire

management distribution. .4 Power boxes are attached to the framing structure.

3. Execution 3.1. EXAMINATION

.1 Verify that the building conditions are ready to receive partitions and that dimensions are as instructed by the manufacturer.

3.2. INSTALLATION

.1 Install partition system in accordance with manufacturer’s instructions.

.2 Install ceiling track continuously and secure with non-marring attachment clips.

.3 Install wall start channels where required.

.4 Lift wall start panel frames into ceiling track, and engage side extension into

wall start channel. Ensure frame is plumb and level, adjust as required.

.5 Lift solid panel frames into ceiling track, and place the base track so that the panel is plumb, adjust as required.

.6 Lift door or glazing frame into ceiling track, and place base track or door base

plates to that the frame is plumb, adjust as required.

.7 Connect the unitized frames together with joint clips to ensure proper spacing.

.8 Feed power or communication cables through framing as required

.9 Snap on face panels as instructed by the manufacturer.

Section 10 22 00 Moveable Partitions

Page 8 3.3. ADJUSTING

.1 Replace damaged components with new to match.

.2 Touch up minor scratches to match factory finish.

.3 Adjust doors to operate smoothly. 3.4. CLEAN UP

.1 Upon completion of work, this contractor shall remove all of his cartons, trash, crates, etc. and leave the premises broom clean.

END OF SECTION

Executive Series Product Information

General Description

The Executive Series – The next generation in Movable walls. Pre-engineered and 100% factory

fabricated, the system provides a unitized and modular feature which allows for quick install and easy

relocation. With snap on panels, electrical kits, and an array of finishes. The design possibilities are

endless!

Wall thickness

4-1/4”, 108mm

Cavity space

3” inside, 76mm

Solid wall Face panels

Standard

5/8” thick melamine coated particle board, also known as Low pressure laminate or

Thermally Fused Melamine (TFM).

Options

o 5/8” thick Vinyl or Fabric covered MDF

o Fabric covered Cork faced tackable panels

o 5/8” thick High pressure laminate covered panels (Arborite, formica, etc.)

o Wood veneer panels, capability to have the grains matched and sequenced

o Back painted glass whiteboards

o Flush mounted display screens

o Large format photos mounted to face panels for displays or murals

o Slot wall, available in TFM or High pressure laminated panels only (Design of

aluminum slot wall in the works, this would be painted)

Door types

Standard, 1-3/4” thick solid core Hinge doors. Frame and door is handed.

Sliding barn door, on the surface of the wall

Sliding barn door, set into the thickness of the wall with either a fixed glazing section or

fixed matching door section.

Anna
Polygon

Reversible pivot door system is in the works

Door materials

1-3/4” thick Solid core, #1 edge Stain grade veneer doors

o With or without glass insert

o With or without painted saw cut reveal

Aluminum framed glass door

o Painted or Clear anodized finish

o 2-1/4” or 4-1/2” wide stiles

Hardware options

Almost any brand and style of hardware can be used on our doors.

Electrical/Data/Voice system

All solid wall sections will come prepped for the installation of one or more electrical service

kits. These kits can be installed during initial installation or at any later date. The electrical service kit will

come standard with pre-wired power outlets, connected to a BX cable, and empty gang(s) for voice/data

outlets fed by a flex conduit extending into the ceiling space. There will also be electrical service kits for

light switches, thermostats, etc.. The electrical service kits will be CSA certified, although certification

would not necessarily be required since the “electrical inspector” would be able to see the installation if

requested by removal of the face panels. Kits which will be available include:

Single gang power outlet

Double gang power only outlet

Double gang power and voice/data outlet

4 gang power and voice/data outlet

Single gang light switch, decora, toggle or customer supplied

Single gang box for thermostat mounting, thermostats can also be installed without the use of

an electrical service kit.

Single gang voice/data outlet

Adjustability

The Executive Series wall system can handle a floor variation of up to 3”(76mm).

For areas with multiple Ceiling heights, the frames are manufactured for easy installation of an

extension section to transition from one ceiling height to the next. The maximum height of the

extension section is 18” (457mm). The minimum height of an extension section is 4” (102mm).

STC

STC of 46, with 2” sound attenuation blanket installed in cavity

STC of 51, with 2” sound attenuation blanket installed in cavity and 1/2” drywall glued to the

back of the face panels

STC of 44, with two layers of ½” acoustical duct liner attached to ¼” thick perforated hardboard

framed and installed into the cavity.

Glazing

Single glazing available with 4mm (3/16”), 6mm (1/4”) or 10mm (3/8”) glass

Double glazed available with two layers of 6mm (1/4”), two layers of 4mm(3/16”) or one layer of

6mm(1/4”) and one layer of 4mm(3/16”)

All configurations can handle any clear, tinted, frosted or textured glass types

Fire Rating

Class A fire rated panels are available.

Compatibility with other wall systems

The Executive series can be connected seamlessly to Drywall, Demountable wall systems (PS-

350), and Unitized wall systems (Corporate).

Minimum and maximum wall and panel sizes

Wall height restrictions:

Maximum wall height, 12 feet (3657mm), for full height installation

Maximum wall height, 8 feet (2438mm), for partial height installation

Panel size restrictions:

Minimum panel width 4-1/4” (108mm)

Maximum face panel dimensions, 5’x 10’ (1524mm x 3048mm)

Furniture and accessory attachment methods

Many furniture systems can be attached to the Executive wall system. This is done by the

installation of a slotted standard into the gap between face panels or along our horizontal rail system

allowing for off module furniture attachment. For some Furniture systems the width of the standard

required is wider than our gap, therefore the panels need to be adjusted to accommodate the

attachment. This can easily be done, but will require panel dimensions to be changed to accommodate

the wider standard.

Accessories available

Slot wall accessories are available from most office supply distributors.

Picture hooks, which attach to the face panels without damage are available

Marker trays for white boards are available

Coat hooks which attach to the top edge of face panels are available

Small shelves which attach to the top edge of face panels are available

Conversion of solid to glazing

Any Executive frame can be converted on site from Glazing to Solid or Solid to Glazing. The

section of wall does not need to be removed for this transformation. A Glazing kit would be ordered

from Partition Systems and shipped to site. The installer would be able to make the transition in about

1-2 hours. The only constraint is there can not be any electrical running through the area if it is to be

made into a glazing section.

Partial height system

The Executive Series can be configured as a partial height system and maintain all of its

functionality.

Environmental benefits

No PVC components are used in the Executive wall system

Wall system is 100% re-usable

Aluminum framing is 100% recyclable

Face panels are made from Recycled wood products

Clean installation, no adhesives or dust on site

Anna
Polygon

Leeds points that the Executive Series could possibly contribute to:

o Materials & Resources, Credit 1.2, 1.3, Building re-use, on renovations

o Materials & Resource, Credit 3.1, 3.2, Resource re-use, on renovations

o Materials & Resource, Credit 4.1, 4.2, Recycled content

o Materials & Resource, Credit 5.1, 5.2, Regional Materials

o Materials & Resource, Credit 7, Certified wood

o Indoor Environmental Quality, Credit 4.4 or 4.5, Low emitting materials

Structural ratings

Loads attached to the face panels are limited to 50 pounds (22.7 Kg) for a vertical load, or 15

pounds (6.8 Kg) for a cantilevered load. This is the allowable load applied per panel (See

detailed loading conditions sheet).

Loads attached to the slotted standards in the gaps between face panels are limited to 400

pounds (182Kg) vertical load per side, but the torque must be limited to 2400 inch pounds (27.7

Kg m), this means that a load of 200 pounds must be centered no more than 12 inches away

from the face of the wall.

The maximum total load which can be applied to one section of wall is 800 pounds (364Kg).

At the above load ratings there will be no permanent damage to the wall or its

components.

Trims

The Executive Wall system was designed to eliminate the use of top and base trims and any PVC

products. Panels are used above and below windows on all glazing, doors and solid panels.

Lead time

Once signed off drawings are received, the lead time may vary from 2 to 6 weeks depending on

the size of the project.