2/15/18 1 Myopia, The Refrac5ve Market and Phakic IOLs in Modern Refrac5ve Surgery David W. Friess, OD, FAAO Head of Global Professional Affairs Staar Surgical Company President, OCCRS Optometric Cornea, Cataract and Refrac5ve Society Financial Interest Disclosures STAAR Surgical Co. Employee, Shareholder Op5mus Clinical Partners LLC President/Owner

Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

1

Myopia,TheRefrac5veMarketandPhakicIOLsinModernRefrac5veSurgery

DavidW.Friess,OD,FAAO

HeadofGlobalProfessionalAffairsStaarSurgicalCompany

President,OCCRS

OptometricCornea,CataractandRefrac5veSociety

FinancialInterestDisclosures

•  STAARSurgicalCo.–Employee,Shareholder

•  Op5musClinicalPartnersLLC–President/Owner

Page 2: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

2

PhakicIOLProductInforma5on

•  ATTENTION:ReferencetheVisianICL™andVerisyse™ProductInforma5onforacompletelis5ngofindica5ons,warningsandprecau5ons.

Refrac5veMarketSta5s5cs

•  IncludesUS/Canada/MexicoLASIK,PRK/surfaceabla5on,phakicIOLs,andrefrac5velensexchange

•  20071M+refrac5veprocedures•  2013600,0001

•  2015visioncorrec5onmarketintheUS2:–  Over60%requirevisioncorrec5on(nearly200Mpeople)–  Spectacles,contactlenses–  Refrac5vesurgerypenetra5onremainsatlessthan3%–  600,000refrac5veproceduresin2015

•  2016Q1MarketScope:–  172,000refrac5veprocedures

1.Cataract&Refrac5veSurgeryToday,July20142.TheVisionCouncil.heps://www.thevisioncouncil.org/topic/problems-condi5ons/adults

Page 3: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

3

Refrac5veOpportunity:Boomersvs.Millennials

•  USCensusBureauEs5mates1:–  75.4millionBabyBoomersin2014.Ages51to69in2015.–  74.8millionMillennialsin2014.Ages18to34in2015.–  By2015,Millennialsincreasedto75.3millionandbecamethebiggestgroup.

1.hep://www.pewresearch.org/fact-tank/2015/01/16/this-year-millennials-will-overtake-baby-boomers/

MyopiaResearchandCoverageinMainstreamMedia

•  HuffingtonPost,03/22/2016:NearsightednessHasaFar-ReachingImpactAstheMyopiaEpidemicSpreadsAroundtheGlobe

–  ReferencesnewresearchfromtheBrienHoldenVisionIns5tute(AUS)studyontheprevalenceofmyopia

•  HoldenBA,etal.GlobalPrevalenceofMyopiaandHighMyopiaandTemporalTrendsfrom2000through2050.Ophthalmology.2016May;123(5):1036-42.–  Myopiaisprojectedtoaffectalmosthalfoftheworld’spopula5onby2050—

asevenfoldincrease–  5billionwithmyopia–  1billionwithhighmyopia(>-6D)–  UnitedStatesandCanadaincreaseto260million,orclosetohalfofthe

popula:on,upfrom89millionin2000–  Highmyopiacasesincreasebyfive:mesto66million

Page 4: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

4

KeyMyopicTreatmentGoals•  Desiretreatmentswith…

–  HighSafetyIndexPostopBCVA/PreopBCVA–  HighEfficacyIndexPostopUCVA/PreopBCVA–  Aeemptedvs.AchievedRx-accurateandstable–  Lowrateofcomplica5ons–  Preservecornealintegrityandlensforfutureprocedures–  Lowdryeyerisk–  Similartreatmentacrossabroadrangeofrefrac5ons–  Highpa5entsa5sfac5on

PhakicIOLs•  Variablematerials

–  Plas5c–  Silicone–  Collagen(Collamer)-STAARVisianICL

•  VariabledesignsAnteriorChamber●  Acrysof,Alcon●  GBR,IOLTech●  KelmanDuet,Tekia●  MemoryLens,Ciba●  NewLife,IOLTech●  NuVita,B&L●  ThinOptX●  VisionMembrane●  6H2,Oll

IrisSupported●  Ar>san,Ophtec●  Verisyse,AMO

PosteriorChamber●  PRL,Ciba●  VisianICL,STAAR

Page 5: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

5

FDAApprovalsforPhakicIOLsforMyopia

•  2004–Verisyse®anteriorchamberphakicIOL(AMO,Inc.)•  2005–VisianICL™posteriorchamberphakicIOL(STAAR

SurgicalCo.)

www.allaboutvision.com/visionsurgery/implantable-lenses.htm

Verisyse™Anteriorchamberirisfixated

phakicIOL(AMO,Inc.)

8.5mmonepiecePMMA5.0mmand6.0mmop5c

hep://abboemedicalop5cs.com/products/cataract/refrac5ve-iols/verisyse-phakic-iolLouisJ.Catania©2007NicolitzEyeConsultants

Page 6: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

6

Verisyse®PhakicIOLProductLabeling

•  Indica5on:•  Verisyse®intraocularlensesareindicatedforthereduc5onorelimina5on

ofmyopiainadultswithmyopiarangingfrom-5.0to-20.0diopterswithlessthanorequalto2.5dioptersofas5gma5smatthespectacleplaneandwhoseeyeshaveananteriorchamberdepthgreaterthanorequalto3.2millimeters;and,pa5entswithdocumentedstabilityofrefrac5onfortheprior6months,asdemonstratedbysphericalequivalentchangeoflessthanorequalto0.50diopters.

hep://abboemedicalop5cs.com/products/cataract/refrac5ve-iols/verisyse-phakic-iol

Louis J. Catania © 2007 Nicolitz Eye Consultants

Page 7: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

7

VisianICL™V4DesignPosteriorChamberPhakicIOL

ICLDesign•  PosteriorChamberPhakicIOL•  Hap5csplacedinsulcus-stability•  Op5cVaultbydesign

–  500umoverthecentralcrystallinelens

•  Orienta5onmarksforproperplacementandalignmentininjector

•  Smallincisionrefrac5vesurgery•  Foldableandinjectablethrougha3.5mmorlessincision

Page 8: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

8

COLLAGEN COPOLYMER

CollamerSummary•  Collagenmatrix•  Hydrophilic•  Biocompa5bility•  Refrac5veindex=1.44•  Elas5c:Gentleunfolding•  Tensilestrength:Strong,resiststearing•  UVblockingchromophore•  Lathecutdesign•  StoredinBSS

Page 9: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

9

PeripheralIridotomy

•  TwoYAGiridotomies(0.5mm;placedsuperiorly,90degreesapart)shouldbeperformed2to3weekspriortosurgerywithconfirma5onofthepatencyoftheiridotomiespriortolensimplanta5on.

STAARFDAMICLDirec5onsforUse(DFU)

Direc5onof

Implanta5on

Orienta5onMarks

TrailingLew

LeadingRight

Page 10: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

10

VisianICL–ImplantableCollamerLens

Indica5onsforUse•  TheVisianICLisindicatedforuseinadults21-45yearsofage:1.  Forthecorrec5onofmyopiainadultswithmyopiaranging

from-3.0Dto≤-15.0Dwithlessthanorequalto2.5Dofas5gma5smatthespectacleplane;

2.  Forthereduc5onofmyopiainadultswithmyopiarangingfromgreaterthan-15.0Dto-20.0Dwithlessthanorequalto2.5Dofas5gma5smatthespectacleplane;

3.  Withananteriorchamberdepth(ACD)of3.00mmorgreater,andastablerefrac5vehistory(within0.5Diopterfor1yearpriortoimplanta5on).

STAARFDAMICLDirec5onsforUse(DFU)

Page 11: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

11

VisianICL™(ImplantableCollamerLens)forMyopiaForthecorrec5on/reduc5onofmoderatetohighmyopia

•  FDADirec5onsforUse(DFU)DeviceDescrip5on

STAARFDAMICLDirec5onsforUse(DFU)

Contraindica5ons•  TheVisianICLiscontraindicatedinpa5ents:

1.  Withananteriorchamberdepth(ACD)of<3.00mm;2.  WithanteriorchamberanglelessthanGradeIIIasdeterminedby

gonioscopicexamina5on;3.  Whoarepregnantornursing;4.  Lessthan21yearsofage;5.  Whodonotmeettheminimumendothelialcelldensity.

STAARFDAMICLDirec5onsforUse(DFU)

Page 12: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

12

Packer,2016:Meta-AnalysisofICLPapers

•  Broadrangeofcorrec5ons•  Highquan5tyofvision•  Highqualityofvision•  Lowincidenceofcomplica5ons

withgoodpa5entselec5on•  Highbenefittoriskra5o

PackerM.Meta-analysisandreview:effec5veness,safety,andcentralportdesignoftheintraocularcollamerlens.ClinOphthalmol.2016;10:1059–1077.

VISIANICL™QUALITYOFLIFEVS.GLASSES,CONTACTLENSESANDLASIK

53.850.2

46.744.1

0

10

20

30

40

50

60

PostICL(n=34) OtherRefrac5veSurgery(n=104)

ContactLenses(n=104) Spectacles(n=104)

QIRCScores

1.IeongA,Hau,S,RubinGS,Allan,B.QualityofLifeinHighMyopiabeforeandawerImplantableCollamerLensImplanta5on.Ophthalmology2010;117:2295-23002.PesudovsK,GaramendiE,EllioeDB.Aqualityoflifecomparisonofpeoplewearingspectaclesorcontactlensesorhavingundergonerefrac5vesurgery.JRefractSurg2006;22:19–27.

Ieongetal Pesudovsetal

Page 13: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

13

•  EfficacyIndex:Post-opUCVA/Pre-opBCVA1

•  Seeingwell“rightoffthetable”5

•  Long-Term(5yr)Refrac5veStability4

Procedure EfficacyIndex

VisianICL™ 0.96–1.011,2,3

1.  UCVA=UncorrectedVisualAcuity,BCVA=BestCorrectedVisualAcuity2.  LisaC,AlfonsoJF,Alfonso-BartolozziB,Fernández-VegaL,Pérez-VivesC,Montés-MicóR.Collagencopolymerposteriorchamberphakicintraocularlenssupportedbythe

ciliarysulcustotreatmyopia:one-yearfollow-up.JCataractRefractSurg.2015Jan;41(1):98-104.3.  HuseynovaT,OzakiS,IshizukaT,MitaM,TomitaM.Compara5vestudyof2typesofimplantablecollamerlenses,1withand1withoutacentralar5ficialhole.AmJ

Ophthalmol.2014Jun;157(6):1136-43.4.  ShimizuK,KamiyaK,IgarashiA,KobashiH.Long-TermComparisonofPosteriorChamberPhakicIntraocularLensWithandWithoutaCentralHole(HoleICLandConven5onal

ICL)Implanta5onforModeratetoHighMyopiaandMyopicAs5gma5sm.Medicine.2016Apr;95(14):e3270.5.  StevenS.Lane,MD,quotedinHelznerJ,PhakicIOLs:ReadyforaBreakthrough?OphthalmologyManagementMarch1,2011.

hep://www.ophthalmologymanagement.com/ar5cleviewer.aspx?ar5cleid=105346(AccessedAugust6,2016).

WELLESTABLISHEDBENEFITS

USMILITARYWARFIGHTERS1

1.ParkhurstGD,PsolkaM,KezirianGM.PhakicIntraocularLensImplanta5oninUnitedStatesMilitaryWarfighters:ARetrospec5veAnalysisofEarlyClinicalOutcomesoftheVisianICL.JRefractSurg.2011;27(7):473-481.

•  Retrospec5ve,interven5onalconsecu5vecaseseriesassessingshort-term(3months)clinicaloutcomesawerVisianICL™implanta5oninUSmilitarywarfighters

•  135eyesof69pa5entswhowerenotgoodcandidatesforlaservisioncorrec5on

•  Age:30.9+/-6.6years•  Pre-OpMRSE:-6.00+/-1.92D

(range:-2.63to-11.50D)

Page 14: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

14

USMILITARYWARFIGHTERS1

1.ParkhurstGD,PsolkaM,KezirianGM.PhakicIntraocularLensImplanta5oninUnitedStatesMilitaryWarfighters:ARetrospec5veAnalysisofEarlyClinicalOutcomesoftheVisianICL.JRefractSurg.2011;27(7):473-481.

•  ICLPredictability:•  90%+/-0.50D•  99%+/-0.75D

USMILITARYWARFIGHTERS1

•  ICLVisualAcuity

1.ParkhurstGD,PsolkaM,KezirianGM.PhakicIntraocularLensImplanta5oninUnitedStatesMilitaryWarfighters:ARetrospec5veAnalysisofEarlyClinicalOutcomesoftheVisianICL.JRefractSurg.2011;27(7):473-481.

Page 15: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

15

VISIANICL™VS.WFG-LASIK1:CONTRASTSENSITIVITY(HIGHMYOPIA)

1.IgarashiA,KamiyaK,ShimizuK,KomatsuM.VisualPerformanceawerImplantableCollamerLensImplanta5onandWavefront-GuidedLaserInSituKeratomileusisforHighMyopia.AmJOphthalmol2009;148:164-170.

•  ICL:SignificantIncrease(p<0.001) •  WFG-LASIK:Significantdecrease(p=0.001)

VISIANICL™VS.WFG-LASIK1:CONTRASTSENSITIVITY(LOWTOMODERATEMYOPIA)

1.KamiyaK,IgarashiA,ShimizuK,MatsumuraK,KomatsuM.VisualPerformanceAwerPosteriorChamberPhakicIntraocularLensImplanta5onandWavefront-GuidedLaserInSituKeratomileusisforLowtoModerateMyopia.AmJOphthalmol2012;153:1178-1186.

•  ICL:SignificantIncrease(p<0.001) •  WFG-LASIK:Nochange(p=0.11)

Page 16: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

16

Publica5onReview:Aprospec5vecomparisonofphakiccollamerlenses

andwavefront-op5mizedlaser-assistedinsitukeratomileusisforcorrec5onofmyopia.

ParkhurstGD.Aprospec5vecomparisonofphakiccollamerlensesandwavefront-op5mizedlaser-assistedinsitukeratomileusisforcorrec5onof

myopia.ClinOphthalmol.2016Jun29;10:1209-15.

StudyMethods•  Refrac5veSurgeryCenter,CarlRDarnallArmyMedicalCenter,FortHood,

TX•  Prospec5ve,non-randomizedcomparisonof48militarypersonnel(95

eyes)whounderwenteitherVisianICLimplanta5onorwavefront-op5mizedLASIKwithWaveLightAllegreeoEye-Q400Hzexcimerlasersystem–  Allthepa5entscompletedthe3-monthfollow-upperiod

•  Subjectswereincludedwith:–  Stablerefrac5veerror(changeofsphericalequivalent<0.50Dforatleast1

year)–  Myopia>−3.00D(range:–3.00Dto–11.50D)withas5gma5sm<3.00D

ParkhurstGD.Aprospec5vecomparisonofphakiccollamerlensesandwavefront-op5mizedlaser-assistedinsitukeratomileusisforcorrec5onofmyopia.ClinOphthalmol.2016Jun29;10:1209-15.

Page 17: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

17

StudyMethods•  Agewascomparablebetweenthetwogroups

–  ICL=27.6±7.3years(range=19–46years)–  LASIK=27.0±5.9years(range=20–41years)

•  Nosignificantdifferencebetweentwogroupsinpreopera5vesphericalequivalent–  ICL=−6.10±1.76D(range:−3.25Dto−11.50D)–  LASIK=−6.04±1.72D(range:−3.00Dto−9.50D)

•  Scotopicpupildiameterswerealsocomparable–  ICL=6.37±1.01mm(range=4.5–8mm)–  LASIK=6.23±0.88mm(range=4–8mm)

ParkhurstGD.Aprospec5vecomparisonofphakiccollamerlensesandwavefront-op5mizedlaser-assistedinsitukeratomileusisforcorrec5onofmyopia.ClinOphthalmol.2016Jun29;10:1209-15.

StudyMethods

•  RabinSuperVisionTest–  PrecisionVision,LaSalle,IL,USA–  High-contrastvisualacuity–  Leeercontrastsensi5vity

Page 18: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

18

StudyMethods•  RabinSuperVisionTestwasusedtocomparethevisualacuity

andCSineachgroupundernormalandlowlightcondi5ons,usingafilterforsimulatedvisionthroughnightvisiongoggles(NVG).–  NVGspresentpar5cularlychallengingviewingcondi5ons

•  lowluminance•  lossofcolordiscrimina5on•  diminishedcontrast

–  Tes5ngwasconductedwithbestspectaclecorrec5on,firstusingNVGwithlow-luminancefilter,thenwithoutfilter(methodusedtopreventlearning)

ParkhurstGD.Aprospec5vecomparisonofphakiccollamerlensesandwavefront-op5mizedlaser-assistedinsitukeratomileusisforcorrec5onofmyopia.ClinOphthalmol.2016Jun29;10:1209-15.

StudyResults•  Allsurgerieswereuneven�ul,andnovision-threatening

complica5onswereseenthroughouttheobserva5onperiod•  Bothgroupswerecomparablewithrespecttopreopera5ve

visualacui5esandcontrastsensi5vi5es

ParkhurstGD.Aprospec5vecomparisonofphakiccollamerlensesandwavefront-op5mizedlaser-assistedinsitukeratomileusisforcorrec5onofmyopia.ClinOphthalmol.2016Jun29;10:1209-15.

Page 19: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

19

StudyResults:SuperVisionAcuity(SVa)

•  Sta5s5callysignificantimprovementfrompreopera5ve-to-postopera5velevelobservedinbothgroups.

•  At3months,meanimprovementsinSVa(LogMAR)intheICLandLASIKgroupswerecomparable(P=0.154;errorbarsrepresentSD).

ParkhurstGD.Aprospec5vecomparisonofphakiccollamerlensesandwavefront-op5mizedlaser-assistedinsitukeratomileusisforcorrec5onofmyopia.ClinOphthalmol.2016Jun29;10:1209-15.

StudyResults:SuperVisionContrast(SVc)

•  Postopera5veimprovementfrompreopera5velevelswassta5s5callysignificantinbothgroups.

•  Sta5s5callysignificantgreaterimprovementfornormalillumina5onandnightvisionsimula5onintheICLcomparedtoLASIKgroup.

ParkhurstGD.Aprospec5vecomparisonofphakiccollamerlensesandwavefront-op5mizedlaser-assistedinsitukeratomileusisforcorrec5onofmyopia.ClinOphthalmol.2016Jun29;10:1209-15.

Page 20: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

20

StudyResults:SuperVisionAcuitywithGoggles(SVaG)

•  At3months,meanimprovementinSVaG(LogMAR)intheICLgroupwassta5s5callysignificantlygreaterthanthemeanimprovementintheLASIKgroup(P=0.032*;errorbarsrepresentSD).

ParkhurstGD.Aprospec5vecomparisonofphakiccollamerlensesandwavefront-op5mizedlaser-assistedinsitukeratomileusisforcorrec5onofmyopia.ClinOphthalmol.2016Jun29;10:1209-15.

StudyResults:SuperVisionContrastwith(lowluminance)Goggles(SVcG)

•  At3months,meanimprovementinSVcG(LogCS)wassta5s5callysignificantlygreaterintheICLgroupascomparedtotheLASIKgroup(P=0.024*;errorbarsrepresentSD).

ParkhurstGD.Aprospec5vecomparisonofphakiccollamerlensesandwavefront-op5mizedlaser-assistedinsitukeratomileusisforcorrec5onofmyopia.ClinOphthalmol.2016Jun29;10:1209-15.

Page 21: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

21

Conclusion•  Inthisstudy,low-luminancevisualacuityandlow-luminance

CSsignificantlyimprovedfollowingICLimplanta5on,andtheimprovementsweresignificantlybeeerthanthoseobservedawerwavefront-op5mizedLASIK.

ParkhurstGD.Aprospec5vecomparisonofphakiccollamerlensesandwavefront-op5mizedlaser-assistedinsitukeratomileusisforcorrec5onofmyopia.ClinOphthalmol.2016Jun29;10:1209-15.

ASACOMPREHENSIVEREFRACTIVEPRACTICE…

...yourresponsibilityistounderstandthepoten5alrisks1:•  EarlyIOPSpike•  LateCataract

…andbepreparedtomanagethem.

1.  STAARFDAMICLDirec5onsforUse(DFU)

Page 22: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

22

EARLYIOPSPIKE•  FDAStudyMICLDFU6:“RaisedIOPRequiringInterven5on”

§  3.2%(n=17/526)addi5onalLPI§  0.6%(n=3/526)repeatirriga5onandaspira5onat1daypost-op

• Mi5ga5on/Management6:§  ImportanttomonitorIOPat24hourspostopera5vely§  ImportanceofpatentLPIs§  ThoroughremovalofOVD

•  Literature:§  Incidenceofpupillaryblock0.01,3,4,5–0.7%2

1.  IgarashiA,ShimizuK,KamiyaK.Eight-yearfollow-upofposteriorchamberphakicintraocularlensimplanta5onformoderatetohighmyopia.AmJOphthalmol2014;157:532–9.2.  LeeJS,KimYH,ParkSK,LeeSU,ParkYM,LeeJH,LeeJE.Long-termclinicalresultsofposteriorchamberphakicintraocularlensimplanta5ontocorrectmyopia.ClinExperimentOphthalmol.2015Dec12.

doi:10.1111/ceo.12691.[Epubaheadofprint]3.  Higueras-EstebanA,Or5z-GomarizA,Gu5érrez-OrtegaR,Villa-CollarC,Abad-MontesJP,FernandesP,González-MéijomeJM.Intraocularpressureawerimplanta5onoftheVisianImplantableCollamer

LensWithCentraFLOWwithoutiridotomy.AmJOphthalmol.2013Oct;156(4):800-54.  HuseynovaT,OzakiS,IshizukaT,MitaM,TomitaM.Compara5vestudyof2typesofimplantablecollamerlenses,1withand1withoutacentralar5ficialhole.AmJOphthalmol.2014Jun;157(6):1136-43.5.  LisaC,AlfonsoJF,Alfonso-BartolozziB,Fernández-VegaL,Pérez-VivesC,Montés-MicóR.Collagencopolymerposteriorchamberphakicintraocularlenssupportedbytheciliarysulcustotreatmyopia:

one-yearfollow-up.JCataractRefractSurg.2015Jan;41(1):98-104.6.  STAARFDAMICLDirec5onsforUse(DFU)

MULTIPLEETIOLOGIESOFCATARACT

Patient Related Factors1 Surgeon Related Factors1 Visian ICL™ Related Factors1

Age2,3 Surgical trauma Insufficient Vault2,4,5

Refractive status3 •  Early onset (< 3M) associated with surgical trauma

•  Disturbance of aqueous flow1

•  Interference with lens metabolism1

Anterior Subcapsular Cataract (ASC)

1.  Chenetal.MetaanalysisofcataractdevelopmentawerPIOLsurgery.JCataractRefractSurg2008;34:1181–1200.2.  Gonversetal.Implantablecontactlensformoderatetohighmyopia:rela5onshipofvaul5ngtocataractforma5on.JCataractRefractSurg2003;29:918–243.  SandersDR.Anteriorsubcapsularopaci5esandcataracts5yearsawersurgeryinthevisianimplantablecollamerlensFDAtrial.JRefractSurg.2008Jun;24(6):566-704.  Schmidingeretal.Long-termchangesinposteriorchamberphakicintraocularCollamerlensvaul5nginmyopicpa5ents.Ophthalmology2010;117:1506–15115.  Alfonsoetal,Centralvaultawerphakicintraocularlensimplanta5on:Correla5onwithanteriorchamberdepth,white-to-whitedistance,sphericalequivalent,andpa5entageJCataractRefractSurg2012;

38:46–53

Page 23: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

23

INCIDENCEOFMICL/V4ASCCATARACTS

ASCandCataractSurgery N MRSE

(D)FollowUp

ClinicallySignificant

ASC

STAARFDAMICLDFU 526 -10.06 3years 0.4%

KamiyaArchOphthalmol2009 56 -9.83 4years 1.8%

SandersJRefractSurg2007 311 -10.06 5years 1.3%

AlfonsoJCataractRefractSurg2011 188 -10.76 5years 0.5%

AlfonsoJCataractRefractSurg2015 1531 -7.27 5years 1.4%

BrarECOphthalmology2015 615 NR 5years 0.7%

SchmidingerOphthalmology2010 84 -16.40 6years 17%

LeeClinExpOphthalmol2015 281 -8.74 7years 1.8%

0

2

4

6

8

10

12

14

16

18

0 1 2 3 4 5 6 7 8 9

%

Years

IncidenceofV4ASCCataracts

MICLDFU Kamiya2009 Sanders

Alfonso2011 Alfonso2015 Brar2015

Schmidinger2010 Lee2015

PhakicIOLsforMyopia

•  Wellestablishedbenefits•  Lowrateofcomplica5ons•  Broadrangeoftreatment•  Preserva5onofcornealorlen5cular5ssue•  Highpa5entsa5sfac5onandimprovementinqualityoflife

Page 24: Financial Interest Disclosures - Memphis 2020 · 2018-02-16 · Contact Lenses (n=104) Spectacles (n=104) QIRC Scores 1. Ieong A, Hau, S, Rubin GS, Allan, B. Quality of Life in High

2/15/18

24

Summary:Myopia,TheRefrac5veMarketandPhakicIOLsinModernRefrac5veSurgery

•  Myopiaaffectsalargeandgrowingdemographicinneedofvisioncorrec5on

•  Refrac5vesurgeryisaviableop5onformanypa5ents•  PhakicIOLshavealonghistorywithhighbenefittoriskra5o•  Keysincludeproperpa5entselec5on,me5culoussurgeryandgoodclinical

follow-uptoensurepa5entsa5sfac5onandqualityoflifeisdelivered

Thankyou