MINIMUM WIDTH OF AN EXIT DOOR
MINIMUM FLOOR TO CEILING HEIGHT
MAXIMUM STAIR RISE FOR CLASS A STAIR
MAXIMUM HEIGHTS BETWEEN LANDINGS FOR A CLASS A STAIR
MINIMUM HEADROOM FOR CLASS A AND B STAIRS.
UNIT AREA PER PERSON FOR WAITING AREAS OR STANDING ROOM
NUMBER OF EXITS FOR PLACE OF ASSEMBLY FOR 1000 OCCPANTS
TRAVEL DISTANCE TO AN EXIT WITHOUT FIRE SPRINKLER SYSTEM
TRAVEL DISTANCE TO AN EXIT WITH FIRE SPRINKLER SYSTEM
MINIMUM SPACING OF ROWS OF SEATS FROM BACK TO BACK FOR A PUBLIC ASSEMBLY BUILDING
MAXIMUM NUMBER OF SEATS IN A ROW BETWEEN AISLES
MAXIMUM NUMBER OF SEATS IN A ROW OPENING TO AN AISLE ON ONE SIDE
STANDARD WIDTH OF A SEAT WITHOUT DIVIDING ARMS FOR PLACES OF ASSEMBLY
MINIMUM WIDTH OF AN AISLE SERVING AN OCCUPANT LOAD OF 60
MINIMUM HEADROOM CREATED BY ANY PROJECTION FROM THE CEILING
MINIMUM CLEAR WIDTH OF TURNSTILES
MINIMUM DIRECTION WIDTH OF LANDINGS IN THE DIRECTION OF TRAVEL FOR CLASS A AND B STAIRS.
MINIMUM NUMBER OF RISERS IN ANY ONE FLIGHT OF STAIRS.
MINIMUM HEIGHT OF A HANDRAIL ABOVE THE UPPER SURFACE OF THE TREAD
MINIMUM CLEARANCE OF A HANDRAIL FROM ANY WALL
MINIMUM HEIGHT OF A GUARDRAIL
MAXIMUM HEIGHT OF A GUARDRAIL
MINIMUM INNER RADIUS OF A MONUMENTAL STAIR
MINIMUM WIDTH OF ANY BALCONY OR BRIDGE.
MINIMUM WIDTH OF ANY CLASS A RAMP.
MAXIMUM RISE OF ANY FLOOR FROM THE BALCONY TO WHICH AN ACCESS DOOR LEADS.
MAXIMUM VERTICAL HEIGHT IN FLOORS OF AN ESCALATOR.
MINIMUM WIDTH OF A FIRE ESCAPE STAIR FOR EXISTING STAIRS.
MINIMUM WIDTH OF A LANDING FOR A FIRE ESCAPE STAIR FOR EXISTING STAIRS
MINIMUM TREAD FOR FIRE ESCAPE STAIR OF A SMALL BUILDING
MAXIMUM RISE FOR FIRE ESCAPE STAIR OF A SMALL BUILDING
MAXIMUM RISE FOR FIRE ESCAPE STAIR OF EXISTING STAIRS
MAXIMUM RISE FOR FIRE ESCAPE STAIR OF EXISTING STAIRS
MAXIMUM HEIGHT BETWEEN LANDINGS OF A FIRE ESCAPE STAIR FOR EXISTING STAIRS.
MINIMUM HEADROOM CLEARANCE FOR FIRE ESCAPE STAIRS FOR EXISTING STAIRS.
MINIMUM HEADROOM CLEARANCE FOR FIRE ESCAPE STAIRS FOR SMALL BUILDINGS
NUMBER OF EXITS FOR PLACE OF ASSEMBLY FOR 600-1000 OCCUPANTS
MAXIMUM OCCUPANT LOAD FOR CLASS C PUBLIC ASSEMBLY
MINIMUM NUMBER OF EXITS FOR AN INSTITUTIONAL TYPE OF STRUCTURE
MAXIMUM TRAVEL DISTANCE BETWEEN ROOM DOOR INTENDED AS EXIT ACCESS AND EXIT WITH SPRINKLER SYSTEM FOR INSTITUTIONAL USE.
MAXIMUM TRAVEL DISTANCE FROM DOOR OF ANY ROOM TO EXIT FOR HOTELS WITH SPRINKLER
MAXIMUM TRAVEL DISTANCE FROM MAIN ENTRANCE DOOR TO EXIT FOR APARTMENTS WITH SPRINKLER
MAXIMUM INCREASE IN WIDTH FOR AN AISLE PER LINEAR METER
MINIMUM WIDTH OF AN AISLE SERVING AN OCCUPANT OF 60 OR MORE SERVING ONE SIDE OF A PUBLIC ASSEMBLY BUILDING
MINIMUM WIDTH OF AN AISLE SERVING AN OCCUPANT OF 60 OR MORE SERVING TWO SIDES OF A PUBLIC ASSEMBLY BUILDING
MINIMUM WIDTH OF AN AISLE SERVING AN OCCUPANT OF BELOW 60 FOR A PUBLIC ASSEMBLY BUILDING
MINIMUM WIDTH OF AN AISLE FOR AN EDUCATIONAL USE BUILDING
MINIMUM WIDTH OF AN AISLE FOR HOSPITALS OR NURSING HOMES.
MINIMUM WIDTH OF AN AISLE FOR CUSTODIAL CARE INSTITUTIONS.
MINIMUM WIDTH OF AN AISLE FOR BUSINESS USE STRUCTURE
MINIMUM WIDTH OF AN AISLE FOR AN INDUSTRIAL BUILDING
OCCUPANT LOAD PER PERSON FOR LABORATORIES
JAILS ARE CLASSIFIED UNDER WHAT TYPE OF OCCUPANCY?
COURTROOMS WITH AN OCCUPANT LOAD OF MORE THAN 100 ARE CLASSIFIED UNDER WHAT CLASSIFICATION OF OCCUPANY?
ARMORIES WITH AN OCCUPANT LOAD OF MORE THAN 100 ARE CLASSIFIED UNDER WHAT CLASSIFICATION OF OCCUPANCY?
LIBRARIES ARE CLASSIFIED UNDER WHAT CLASSIFICATION OF OCCUPANCY?
ROOMS WHERE BALED, BUNDLED OR PILED MATERIALS SEGREGATED INTO DESIRED SIZES OR GROUPS
BUILDINGS OR STRUCTURES WHICH ARE 15 METERS OR MORE IN HEIGHT?
BUILDINGS OR STRUCTURES USED FOR STORAGE OF EXPLOSIVES, SHELLS, PROJECTILE, ETC.
AN AIR COMPARTMENT OR CHAMBER TO WHICH ONE OR MORE DUCTS ARE CONNECTED AND WHICH FORM PART OF AN AIR DISTRIBUTION SYSTEM
A KIND OF STABLE EXPLOSIVE WHICH EXPLODES BY PERCUSSION
DESCRIPTIVE OF ANY MATERIAL THAT INSTANTLY IGNITES WHEN EXPOSED TO AIR
MATERIAL THAT READILY YEALDS OXYGEN IN QUANTITIES SUFFICIENT TO STIMULATE OR SUPPORT COMBUSTION
A PROCESS WHERE A PIECE OF METAL IS HEATED PRIOR TO CHANGING ITS SHAPE AND DIMENSION
THE PROCESS OF FIRST RAISING THE TEMPERATURE TO SEPARATE THE MORE VOLATILE FROM THE LESS VOLATILE PARTS AND THEN COOLING AND CONDENSING THE RESULT VAPOR AS TO PRODUCE A NEARLY PURIFIED SUBSTANCE.
A FINELY POWDERED SUBSTANCE WHICH WHEN MIXED WITH AIR IN THE PROPER PROPORTION AND IGNITED WILL CAUSE AN EXPLOSION
TEMPERATURE RATING AT FLASH POINT
CLASS OF FIRE WITH FLAMMABLE LIQUID AND GASSES
TEMPERATURE AT WHICH LIQUID IS TRANSFORMED INTO VAPOR
MINIMUM FIRE RESISTANCE RATING FOR FIRE WALL
CONTINUOUS PASSAGEWAY FOR THE TRANSMISSION OF AIR
MINIMUM TEMPERATURE AT WHICH MATERIAL GIVES OFF VAPOR IN SUFFICIENT CONCENTRATION TO FORM AN IGNITABLE MIXTURE WITH AIR
A GAS, FUME OR VAPOR USED FOR THE DESTRUCTION OR THE CONTROL OF INSECTS, FUNGI, VERMIN, GERMS, RODENTS OR OTHER PESTS.
MINIMUM WIDTH OF ANY DRIVEWAY IN AND AROUND A LUMBER YARD/ PILES
MINIMUM HEIGHT OF FENCE FOR A LUMBER YARD FOR EXTERIOR STORAGE OF LUMBER
MAXIMUM WIDTH OF SUMPS FOR THE RETENTION OF OIL AND PETROLIUM PRODUCTS. FOR REFINERIES, DISTILLERIES, AND CHEMICAL PLANTS, MINIMUM HEIHT OF FENCE
MINIMUM TRAVEL DISTANCE FROM ANY INDIVIDUAL ROOM SUBJECT TO OCCUPANCY BY NOT MORE THAN 6 PERSONS
MAXIMUM DISTANCE OF TRAVEL FROM THE HIGH HAZARD AREA TO AN EXIT.
MINIMUM DISTANCE OF AN INCINERATOR FROM ANY STRUCTURE USED OTHER THAN A SINGLE FAMILY DWELLING.
MAXIMUM REDUCTION OF WIDTH OF A STAIR BY A HANDRAIL.
MINIMUM WIDTH OF A SINGLE DOOR IN A DOORWAY
MAXIMUM CHANGE IN ELEVATION BETWEEN THE INTERIOR OF A DOOR TO THE OUTSIDE IF ITS OTHER THAN A BALCONY
MAXIMUM FORCE IN KILOGRAMS REQUIRED FOR A PANIC HARDWARE
MAXIMUM HEIGHT REQUIRED FOR A PANIC HARDWARE
MINIMUM HEIGHT REQUIRED FOR A PANIC HARDWARE
MAXIMUM NUMBER OF OCCUPANTS FOR A SUBDIVIDED ROOM OR SPACE BY A FOLDING PARTITION
MINIMUM WIDTH OF A DOOR FOR FAMILY DAYCARE HOMES
MINIMUM STAIR WIDTH FOR CLASS B STAIRS HAVING AN OCCUPANT LOAD OF MORE THAN 50 OCCUPANTS
IN EXIT HALLWAYS THE WIDTH OF A HALLWAY SHOULD NOT BE REDUCED BY MORE THAN _________ CONSIDERING AN OPENED DOOR
LENGTH OF NOSING OR EFFECTIVE PROJECTION OVER THE LEVEL IMMEDIETLY BELOW IT FOR TREAD BELOW 25 CM IN DIMENSION
MAXIMUM HEIGHT OF HANDRAIL
COMBUSTIBLE LIQUIDS ARE LIQUIDS HAVING A FLASH POINT OF OR ABOVE
THE TIME DURATION THAT A MATERIAL OR CONSTRUCTION CAN WITHSTAND THE EFFECT OF STANDARD FIRE TEST IS KNOWN AS
ANY MATERIAL WHICH BY ITS NATURE OR AS A RESULT OF ITS REACTION WITH THE OTHER ELEMENTS PRODUCES A RAPID DROP IN TEMPERATURE OF THE IMMEDIATE SURROUNDING.
THE TRAVEL DISTANCE TO EXITS SHALL BE FOR MERCANTILE OCCUPANCIES.
UNDER WHAT CLASSIFICATION OF OCCUPANCY DOES POOL ROOMS FALL
UNDER WHAT CLASSIFICATION OF OCCUPANCY DOES HOME FOR THE AGED FALL?
UNDER WHAT CLASSIFICATION OF OCCUPANCY DOES COURT HOUSES FALL?
UNDER WHAT CLASSIFICATION OF OCCUPANCY DOES REFINERIES FALL?
UNDER WHAT CLASSIFICATION OF OCCUPANCY DOES DRUGSTORES FALL?
MINIMUM WIDTH OF AN AISLE FOR MERCANTILE OCCUPANCIES?
MINIMUM NUMBER OF AISLES FOR CLASS A STORES?
MINIMUM CLEAR WIDTH OF AISLES FOR CLASS A STORES?
MINIMUM CLEAR WIDTH OF EXITS THROUGH A COVERED MALL?
MINIMUM HEIGHT OF BUILDINGS REQUIRING AUTOMATIC SPRINKLER PROTECTION?
STANDARD INNER RADIUS OF A CURVED STAIR IN BUSINESS OCCUPANCIES?
MAXIMUM HEIGHT OF RISER FOR CLASS A STAIRS?
MAXIMUM HEIGHT OF RISER FOR CLASS B STAIRS?
MINIMUM WIDTH OF CLASS B STAIRS SERVING MORE THAN 50 PERSONS?
MINIMUM WIDTH OF CLASS B STAIRS SERVING 50 PERSONS AND BELOW?
MINIMUM WIDTH OF CLASS A STAIRS?
MAXIMUM PROJECTION OF A HANDRAIL OVER A STAIR?
MINIMUM HEIGHT BETWEEN LANDINGS FOR CLASS B STAIRS?
MINIMUM WIDTH OF LANDINGS IN DIRECTION OF TRAVEL FOR CLASS A AND B STAIRS?
MINIMUM WIDTH OF CLASS A RAMP?
MINIMUM WIDTH OF CLASS B RAMP?
STANDARD SLOPE OF CLASS B RAMP IN PERCENTAGE?
MAXIMUM HEIGHT BETWEEN LANDINGS FOR A CLASS A RAMP?
MAXIMUM HEIGHT BETWEEN LANDINGS FOR A CLASS B RAMP?
MINIMUM WIDTH OF RAMPS FOR 3 OR MORE STORIES IN HEIGHT?
MINIMUM WIDTH FOR FIRE ESCAPE FOR EXISTING STAIRS?
MINIMUM HORIZONTAL DIMENSION OF ANY LANDING OR PLATFORM FOR EXISTING STAIRS FOR FIRE ESCAPE?
MAXIMUM RISE FOR FIRE ESCAPE IN SMALL BUILDINGS?
MAXIMUM HEIGHT BETWEEN LANDINGS FOR FIRE ESCAPE FOR EXISTING STAIRS?
MINIMUM DISTANCE OF TRAVEL TO AN EXIT FOR STORAGE OF HIGH HAZARD COMMODITIES?
CLASS OF FIRE INVOLVING COMBUSTIBLE METALS, SUCH AS MAGNESIUM, SODIUM, POTASSIUM, AND OTHER SIMILAR MATERIALS?
CLASS OF FIRE INVOLVING COMBUSTIBLE MATERIALS, SUCH AS WOOD, PAPER, CLOTH, RUBBER AND PLASTICS?
A TANK VAT OR CONTAINER OF FLAMMABLE OR COMBUSTIBLE LIQUID IN WHICH ARTICLES OR MATERIALS ARE IMMERSED FOR THE PURPOSE OF COATING, FINISHING, TREATING OR SIMILAR PROPERTIES?
AN INTEGRATED SYSTEM OF UNDERGROUND OR OVER HEAD PIPING OR BOTH CONNECTED TO A SOURCE OF EXTINGUISHING AGENTS OR MEDIUM AND DESIGNED IN ACCORDANCE WITH FIRE PROTECTION ENGINEERING STANDARDS WHICH WHEN ACTUATED BY ITS AUTOMATIC DETECTING DEVICE, SUPPRESSES FIRE WITHIN THE AREA PROTECTED
A CONTINUOUS AND UNOBSTRUCTED ROUTE OF EXIT FROM ANY POINT IN A BUILDING TO A PUBLIC WAY
MINIMUM DISTANCE OF AN INCINERATOR CONTAINING KINDLED FIRE OR RUBBISH FIRE OR BONFIRES
UNDER WHAT CLASSIFICATION DO MUSEUMS FALL UNDER?
UNDER WHAT CLASSIFICATION DO TOWN HALLS FALL UNDER?
MAXIMUM WIDTH OF A SINGLE DOOR IN A DOORWAY?
MINIMUM TREAD FOR FIRE ESCAPE STAIRS FOR EXISITING STAIRS?
MAXIMUM SPACING OF RUNGS FOR A FIRE ESCAPE LADDER?
MINIMUM SPACING OF RUNGS FOR A FIRE ESCAPE LADDER?
CLASS III COMBUSTIBLE LIQUIDS SHALL MEAN ANY LIQUID HAVING A FLASH POINT AT HOW MANY DEGREES CELSIUS?
IN STANDARD SEATING MINIMUM SPACING BACK TO BACK
MINIMUM SPACE FROM THE BACK OF A CHAIR TO THE FRONT OF THE CHAIR BEHIND
MAXIMUM SLOPE FOR AISLES FOR PUBLIC ASSEMBLY STRUCTURES
SIZE OF STANDPIPE PROVIDED FOR EACH STAGE FOR PUBLIC ASSEMBLY BUILDING
OCCUPANT LOAD PER PERSON FOR CLASSROOMS
WHERE EXTERIOR CORRIDORS OR BALCONIES ARE PROVIDED AS MEANS OF EXIT, THEY SHALL OPEN TO THE OUTSIDE AND SHALL BE SPACED ______ METERS APART. (EDUCATIONAL)
MINIMUM DIMENSION OF A RESCUE WINDOW FOR EDUCATIONAL OCCUPANCIES
MAXIMUM HEIGHT FROM THE FLOOR FOR A RESCUE WINDOW FOR EDUCATIONAL OCCUPANCIES
MINIMUM WIDTH OF CORRIDORS, AISLES, AND RAMPS FOR EXITS IN HOSPITALS AND NURSING HOMES
MINIMUM WIDTH OF CORRIDORS, AISLES, AND RAMPS FOR EXITS IN RESIDENTIAL CUSTODIAL CARE
ANY ROOM FOR SLEEPING IN INSTITUTIONAL OCCUPANCIES IF SUBDIVIDED SHALL HAVE A MAXIMUM AREA OF HOW MANY SQUARE METERS.
INCLUDES BUILDINGS OR GROUPS OF BUILDING UNDER THE SAME MANAGEMENT IN WHICH THERE ARE MORE THAN 15 SLEEPING ACCOMODATIONS FOR HIRE.
INCLUDES BUILDINGS CONTAINING THREE OR MORE LIVING UNITS INDEPENDENT COOKING AND BATHROOM FACILITIES, WHETHER DESIGNED AS ROWHOUSE, APARTMENT HOUSE, TENEMENT, GARDEN APARTMENT, OR BY ANY OTHER NAME.
MINIMUM NUMBER OF STORIES OF APARTMENT BUILDINGS REQUIRING FIRE ALARM SYSTEM
MINIMUM NUMBER OF APRTMENT UNITS REQUIRING A FIRE ALARM SYSTEM