Fire Extinguishers Suppression Systems

Embed Size (px)

Citation preview

  • 7/31/2019 Fire Extinguishers Suppression Systems

    1/15

    Know You System

    Fire Extinguisher & Suppression

    Activation Training

  • 7/31/2019 Fire Extinguishers Suppression Systems

    2/15

    Fire Extinguishers

    &

    Fire Suppression Systems

    Inspection

    Maintenance

    Activation Procedure

    First-Aid Measures

    Personal Protection Fire Prevention

  • 7/31/2019 Fire Extinguishers Suppression Systems

    3/15

    Daily Inspection

    Inspection is a quick check to verify that the Fire Ext.is in the proper place & in good working order.

    On Cartridge Operated Exts- check that the red stemon top of the cap is in the down position.

    Check to see if the plunger has been activated & seal isintact.

    Check exterior housing and hoses for defects. Check for proper & current certification stickers.

    Check the mounting bracket for defects.

  • 7/31/2019 Fire Extinguishers Suppression Systems

    4/15

    Inspection Cont.

    On Stored Pressure Exts- check that the

    indicator on the gauge is in the green area. If it is

    in overcharged or undercharged range replaceunit.

    Inspect activation pin, seals,

    Inspect hose, nozzle, housing, mounting bracket.

    Check for proper certifications sticker.

  • 7/31/2019 Fire Extinguishers Suppression Systems

    5/15

    Inspection Cont.

    On Mobile Equipment fire suppression systems-check that the pull pin & red actuator knob is in

    place at all activation points.Check all hoses, connection, nozzles, unit

    housing and mounting for defects.

    Check for proper certifications stickers. If any of these components are defective, get the

    unit checked or serviced. Before operation.

  • 7/31/2019 Fire Extinguishers Suppression Systems

    6/15

    Steps of a Physical Inspection of

    a Fire Suppression Systems

    Inspect all activation

    points.

    Check unit for pin,handle, safety clips

  • 7/31/2019 Fire Extinguishers Suppression Systems

    7/15

    Steps of a Physical Inspection of

    a Fire Suppression Systems Cont.

    Inspect hose & spray

    nozzles for damage,

    kinks, or missing parts,etc.

    If integrity of the system

    has been compromised

    shut it down, get it fixed.

  • 7/31/2019 Fire Extinguishers Suppression Systems

    8/15

    Steps of a Physical Inspection of

    a Fire Suppression Systems Cont.

    Visually inspect the gascartridges for damage.

    Inspect extinguisher unitfor damage.

    Report & repair anysubstandard units.

    Make sure unit has aState Fire MarshallSticker.

  • 7/31/2019 Fire Extinguishers Suppression Systems

    9/15

    Maintenance

    Maintenance is a through check of fire exts and fire

    suppression systems.

    Maintenance is performed by qualified technicians at aminimum of once a year.

    When you perform your routine inspections, check the

    maintenance date on the sticker.

  • 7/31/2019 Fire Extinguishers Suppression Systems

    10/15

    Proper Step to Activate a Fire

    Suppressions System.

    1. Stop & Rib all movingequipment.

    2. Lower all raisedattachments.

    3. Shut down engine.

    4. If possible turn masters

    switch off.5. Activate the fire

    suppression system.

  • 7/31/2019 Fire Extinguishers Suppression Systems

    11/15

    Proper Steps to Activate Fire

    Suppression Cont.

    Exit the vehicle once the fire is out or knocked down safely so

    you can leave unharmed.

    If safe to do so secure the hand held ext. in case a flair up of

    the fire reoccurs.

    If the suppression can not put out the fire, this unit can be used

    to help you escape.

    Call Dispatch or Hoistman as soon as possible, notifying the

    type of emergency.

    Put on self rescuer, exit to refuge or out of the mine per

    company procedures.

  • 7/31/2019 Fire Extinguishers Suppression Systems

    12/15

    First Aid Measures

    Eye contact: wash with water for a minimum of

    15 minutes.

    Skin contact: Wash area with soap and water.

    Inhalation: Remove from exposure.

    Ingestion: Give large amounts of water and

    induce vomiting.

  • 7/31/2019 Fire Extinguishers Suppression Systems

    13/15

    Fire Prevention, Removing the Potential

    for Fire Occurrences. An Ounce of

    Prevention Is Worth a Pound of Cure. Good Housekeeping is a must. Check for and remove

    all rags, paper, or combustible products from engine, orpower train compartments daily.

    Keeping machine in good operating conditions; inspectunit for leaks, drips, chaffed hoses in areas where heatcan be generated.

    Wash off any accumulated hydraulic oil, fuels, orgrease, if hydraulic hose fails in the area, wash offarea before beginning, dont burn it off with radiate heatfrom engines, this can cause a fire.

  • 7/31/2019 Fire Extinguishers Suppression Systems

    14/15

    Dont Try This at Home

  • 7/31/2019 Fire Extinguishers Suppression Systems

    15/15

    Any Questions?

    Preventing Conditions That

    Contribute to Possible Mine Fires is

    Everyones Responsibility.

    Got Safety?Created By Pat Gazewood