UPRN
Full Address
Prepared by Karen Daykin
On date 21 June 2014
For Responsible
Person Bluezone Ltd
Woodberry CloseCanvey Island, SS8 9PP
Telephone 01268 697815EmailWebsite
Site Contact name Telephone
Date of Review
FIRE RISK ASSESSMENT
The Fire Risk Assessment is kept at the Head Office of Bluezone Ltd. A duplicate should be available on each site. It should be available for
audits undertaken by the appropriate enforcement authority.
Woodberry Manor
REGULATORY REFORM (FIRE SAFETY) 2005
Ray Woodberry01268 697815
Type of Fire Risk Assessment
Block Risk Assessment
Sleeping AccommodationFull Fire Risk Assessment
Medium - Renew FRA at least every three years
21 June 2017
UPRNFull AddressDate 21 June 2014
Contents
1. Introduction
8. Photographs
The responsible person must take general fire precautions as will ensure so far as is reasonably practicable the safety of any employees and
also in relation to relevant persons who are not in their employ take such general fire precautions as may reasonably be required in the
circumstances of the case to ensure that the premises are safe.
Regulatory Reform (Fire Safety) Order 2005 Article 9 requires that every responsible person must make a suitable and sufficient assessment of
the risks to which relevant persons are exposed for the purpose of identifying the general fire precautions needed to take to comply with the
requirements and prohibitions imposed by or under the order.
The responsible person (or other person who has to any extent control of the property) must ensure that the duties imposed by the relevant
articles of the Regulatory Reform (Fire Safety) Order 2005 are complied with where the matters relate to items within their control.
The prescribed information is the significant findings of the assessment including the measures which have or will be taken by the responsible
person pursuant to the Regulatory Reform (Fire Safety) Order 2005 and any group of persons identified by the assessment as being especially
at risk.
This includes identification of all current significant fire hazards to which relevant persons and others in the area may be exposed.
The Risk Assessment will prioritise the level of risk associated with the property incorporating existing controlling measures to mitigate any risk
The Assessment will also advise upon additional control measures that may me implemented to manage the risk in accordance with Article 10
of the Order.
a. Measures to control sources of ignition
00
1. Introduction2. Scope and Methodology of Assessment3. Identification of Significant Fire Hazards and People at Risk 4. Existing Fire Safety Measures and Occupancy5. Assessment of Fire Risk
b. Measures to control sources of fuelc. Measures to control sources of oxygend. Measures to assist Fire Servicee. Measures to assist Fire Fighters
h. Measures for Signs and Noticesi. Installation, Testing & Maintenancej. Management of Procedures & Information
2. Scope and Methodology of AssessmentStatutory Requirement
6. Fire Risk Rating Matrix7. Fire Risk Assessment Action Schedule
This report has been prepared as the written record of the Fire Risk Assessment carried out to the communal areas of this building on behalf of
the Landlord, Bluezone Ltd, in accordance with the requirements of the Regulatory Reform (Fire Safety) Order 2005.
The objectives of the Fire Risk Assessment are to ensure that a suitable and sufficient assessment of the risks to which relevant persons are
exposed for the purpose of identifying the general fire precautions he needs to take to comply with the requirements and prohibitions of the
Regulatory Reform (Fire Safety) Order 2005.
f. Measures for Fire Detection and Warningg. Measures to assist Means of escape
A Bluezone Ltd Fire Risk Assessment is not a one off document and is part of a strategic Fire Safety Strategy and Policy implemented to identify,
manage and monitor the risks to Bluezone Ltd properties on a regular basis.
The Fire Risk Assessment will be reviewed under Article 9 (3) of the Order and in direct accordance with Bluezone Ltd review policy and
National guidance documentation; this includes but is not restricted to:-
(a) there is reason to suspect that the Fire Risk Assessment is no longer valid;(b) there has been a significant change to which it relates including when the premises, special, technical or organisational measures
undergo significant change, extension or conversion.
(c) Identification of risk following an actual or near miss incident.The report is to provide and assessment of the risk to life from a fire within the building and to make recommendations to ensure compliance
with the Regulatory Reform (Fire Safety) Order 2005; it does not address the risk to the property or business continuity from fire.
Information contained within the report is based on observations at the time of inspection and details provided by on site personnel.
To identify the significant fire hazards within the premises checklists are used which consider the particular fire hazard associated with the
building and the nature of the occupancy.
The hazard will consider the items with regard to existing control measures which are either already inherent within the building or
implemented through the management procedures. The answers are either Yes / No or Not Applicable (N/A).
Each hazard is assessed in accordance with the fire risk rating system. This includes consideration of the hazard in terms of the potential to
harm (severity) and their likelihood (probability) of occurring.
In addition a specific risk rating is applied in consideration of the controlling measures in place and subsequently considers the timescales
within which the measures should be implemented.
The Action plan details the significant findings of both technical and procedural measures that should be considered necessary to address the
risk identified. It is a register of the remedial and advisory actions to be carried out in accordance with the priorities defined using the fire risk
rating system. To reduce the risk to an acceptable level all Action Plan items should be addressed.
The Fire Risk Assessment information is gathered using non invasive physical inspections of the property. Where floor plans are available these
have been used utilised and direct conversation or information has been gathered from on-site staff. Digital photographs have also been taken
and included for means of identification of locations and hazards
The new Regulatory Reform (Fire Safety) Order 2005 requires a fire risk assessment to be carried out and the significant findings recorded. The
process followed was as follows:
The building was inspected, hazards were identified and the fire risk categorised as high, medium or low. The existing measures were recorded
as well as any recommended action. Where actions have been recommended these are in line with British Standards.
Hazards included any sources of ignition (sparks, electrical equipment, heat sources etc), dangerous substances (flammable materials,
combustible materials, gases etc) and unsatisfactory structural features (absence of fire stopping, ducts and voids and compromised protected
routes). Any areas where evacuation of occupants could be compromised were also classed as hazards.
A high fire risk was categorised in areas where there is likely to be a large number of people or old, young or disabled people. Areas with
flammable processes or large quantities of heat or combustible materials were also categorised high risk as well as any areas where structural
features would allow the spread of smoke or fire from one part of the building to another.
A normal fire risk was categorised where a fire is likely to remain localised or to spread slowly enough to allow people to escape to a place of
safety or where there is an effective automatic means of detecting and giving warning of fire.
A low fire risk was categorised where there is minimal risk to life safety and the risk of fire occurring is negligible and the risk of fire, smoke or
fumes spreading is negligible.
Identification of Fire Hazards
Assessment of Fire Risk
The Fire Risk Assessment Action Plan
Information Source
UPRNFull AddressDate 21 June 2014
2
8
1
no
Staircase (element)
yesnoyes
yes
no
Sole Leaseholder or post
1991 converted or purpose
built property
Maximum number of occupants / residents 24
Maximum number of visitors 120
Maximum number of sleeping occupants at any one time 144
Maximum number of vulnerable occupants at any one time 24
Does the tenure include occupants who are:-“Disabled” incl mobility impairment, hearing or vision impairment unknown“Restricted” parents with children unknown“Sensory Impaired” due to alcohol, drugs or medication unknown
Maximum number of unaccompanied children at any one time unknown
Maximum occupation in remote areas at any one time n/a
Accessible by lift / s
Tenure of flats / units
General tenure / occupancy description
4. Identification of People at Risk
Number of Flats within block
Number of direct staircases from corridors
Is there a lobby approach from the staircases to the flats or within the flats?
Fully Enclosed / No Borrowed Light / windowsSemi Enclosed / some Borrowed Light / windowsFully Open / with Borrowed Light / windows
Fully Enclosed / No Borrowed Light / windowsSemi Enclosed / some Borrowed Light / windowsFully Open / with Borrowed Light / windows
Number of Storeys (incl basement)
Date of Construction
Areas not assessed
Two storey tradditional build premise comprising eight residential flats accessed by two
doors front and rear and
0
3. Existing Fire Safety Measures and Occupancy (Static data)
Brief description of building and its construction
No communal Corridors (flats direct to staircases)
Corridors (from the staircases)
1986
Roof void area
0
UPRNFull AddressDate 21 June 2014
Risk Level
1 (Low)
2
3 (Medium)
4
5 (High)
Probability Level1 (Low)23 (Medium)45 (High)
Degree of Risk Risk Rating ScoreHigh 15 – 25Medium High 08 – 12Medium 02 – 06Low Risk 01
Continuous review 00
A Traffic light approach is made in respect of the degree and level of risk, which is also translated into the priority rating for remedial
work or recommendations. Timescales given include consideration for practicality and financial impact to Bluezone Ltd when
planning their implementation. In order to reduce the risk to an acceptable level it is recommended that all Action Plan items are
implemented
5. Risk Matrix
Building / Area should not be occupied until risk is reduced. Fatality or total loss of property
ExposureImprobable – no known instances of occurrence <10%
Essential that efforts are made to reduce the risk; measures to be implemented within set timescales. Serious damage to
propertyConsiderable resources may have to be allocated to reduce the risk; where a building is occupied urgent action should be
undertaken. Permanent injury; permanent damage to property.
The following risk matrix has been used to prioritise and quantify the individual fire safety deficiencies identified.
Action / Consequence
No Further Action is necessary, detailed records needed. No serious injuries, little or no damage to property.
No major additional controls needed consideration for improvements which have minor cost incurrence. Some injury,
remedial works needed to property
00
Unlikely – but still possible 10 -30% Likely to occur 30 - 50 % Will occur frequently 50 - 90% Will occur very frequently unless prevented >90%
Within three years of notification (programmed work)
Within five years of notification (programmed work)
Timescale for actionWithin 28 days of notification
Within six months of notificationWithin one year of notification
UPRNFull AddressDate 21 June 2014
some
no
yes
Zero – 1 fire
yes
some
7. Identification of significant Fire Hazards
Source & location of Ignition123456789
10
Other notes
Source & location of Fuel123456789
10
Other notes
Source and location of oxygen12345
Other notes
Are Estate Management issues being raised and managed effectively?
Is there automatic smoke or fire detection present to the building ?
Fixed lighting equipment
00
Have flat / unit own doors been upgraded to 30 min fire rated?
Is Emergency Lighting installed throughout?
6. Existing Fire Safety Measures and Occupancy (changeable data)
Is the Means of Escape kept clear at all times?
How Many fires have occurred within the block within the past five
Natural airflow
UPRNFull AddressDate 21 June 2014
Item Measures to control Source of
Ignition
N/A Yes No
Ris
k Le
vel
(1-5
)
Pro
bab
ilit
y Le
vel (
1-
Rat
ing
(RLx
P) Priority Comments Action
Point
Ref.
8.1.1 Are current arrangements for the
control of arson suitable and
sufficient?
r a r 0 1 0 Continuous
review
None
8.1.2 Is Smoking confined to
designated areas and “No
Smoking” signs displayed as
appropriate?
r a r 0 1 0 Continuous
review
None
8.1.3 Are suitable arrangements in
place for the disposal of
“smoking” materials
r r a 2 3 6 Medium
Risk
Evidence that residents dispose
of smoking materials at entrance
area.
8.1.3
8.1.4 Is there an adequate system
adopted for permitting and
monitoring hot works operations
by outside contractors?
a r r 0 0 0 Continuous
review
None
8.1.5 Are arrangements for managing
building work and alterations
suitable and sufficient?
r a r 0 1 0 Continuous
review
None
8.1.6 Are adequate measures in place
to guard against malicious
ignition?
r a r 0 2 0 Continuous
review
None
8.1.7 Are Access control / security
systems In place?
r a r 0 1 0 Continuous
review
door entry system not
operational
None
8. Assessment of Fire Risk
The following table details the approach that has been taken to assess the individual risk level for each identified hazard / fire safety deficiency. All
hazards have been considered with regard to the specific relevant people affected and the control measures necessary to contend with the risk.
00
UPRNFull AddressDate 21 June 2014
Measures to control Source of
Fuel
N/A Yes No
Ris
k Le
vel
(1-5
)
Pro
bab
ilit
y Le
vel (
1-
Rat
ing
(RLx
P) Priority Comments Action
Point
Ref.
8.2.1 Have all areas of flammable wall
and ceiling Linings been removed,
covered, or treated to reduce the
spread of flame across their
r a r 0 1 0 Continuous
review
None
8.2.2 Is the premises free from
accumulation of Rubbish, waste
paper, and other ignitable
materials?
r a r 0 1 0 Continuous
review
None
8.2.3 Are adequate arrangements
made for the Disposal of waste
and rubbish?
r a r 0 1 0 Continuous
review
None
8.2.4 Are suitable arrangements in
place for storing highly
flammable or readily
combustible materials not in
current use?
a r r 0 0 0 Continuous
review
None
8.2.5 Are storage areas for highly
flammable and explosive
materials identified by hazard
warning signs
a r r 0 0 0 Continuous
review
None
8.2.6 Are the housekeeping
arrangements for communal
areas sufficiently controlled?
r a r 0 1 0 Continuous
review
None
8.2.7 Are the arrangements for use of
equipment and machinery
suitable and sufficient?
a r r 0 0 0 Continuous
review
None
8.2.8 Is the existing building layout and
construction appropriate, suitable
and sufficient?
r a r 0 1 0 Continuous
review
None
8.2.9 Are areas of high fire risk and
loading provided with physical
separation from the remainder of
the premises?
r a r 0 2 0 Continuous
review
None
8.2.10 Is the provision of means for
restricting spread of fire and
smoke in common areas suitable
and sufficient?
r a r 0 1 0 Continuous
review
None
8.2.11 Is the provision of means for
restricting fire and smoke within
access duct /chutes etc. suitable
and sufficient?
a r r 0 0 0 Continuous
review
None
8.2.12 Is the provision of means for
restricting fire and smoke from
entering into individual flats /
units / areas / linked or attached
properties suitable and
sufficient?
r a r 0 1 0 Continuous
review
None
Measures to control Source of
Oxygen
N/A Yes No
Ris
k Le
vel
(1-5
)
Pro
bab
ilit
y Le
vel (
1-
Rat
ing
(RLx
P) Priority Comments Action
Point
Ref.
8.3.1 Are the communal opening
windows operational?
r a r 0 1 0 Continuous
review
None
8.3.2 Are there smoke vents present –
if they are not present are they
required / recommended ?
a r r 0 0 0 Continuous
review
None
8.3.3 Are air conditioning units present
– if they are not present are they
required / recommended ?
a r r 0 0 0 Continuous
review
None
00
UPRN
Full AddressDate 21 June 2014
Measures to assist fire service N/A Yes No
Ris
k Le
vel
(1-5
)
Pro
bab
ilit
y Le
vel (
1-
Rat
ing
(RLx
P) Priority Comments Action
Point
Ref.
8.4.1 Are there suitable access facilities
for Fire Service vehicles to access
the entire building?
r a r 0 1 0 Continuous
review
None
8.4.2 Are Fire Hydrants in suitable
proximity of building and clearly
visible?
r r a 4 4 16 High Risk No visual evidence of hydrants 8.4.2
8.4.3 Does the Emergency Action Plan
relate to the Fire & Rescue
Service response?
a r r 0 0 0 Continuous
review
None
8.4.4 Are the fire fighting lifts clearly
identified and appropriate
signage fitted?
a r r 0 0 0 Continuous
review
None
8.4.5 Are there Dry / Wet Risers
present – if they are not present
are they required /
recommended ?
a r r 0 0 0 Continuous
review
None
8.4.6 Are the fire fighting lifts clearly
identified and appropriate
signage fitted?
a r r 0 0 0 Continuous
review
None
8.4.7 Are there sprinklers / suppression
systems present – if they are not
present are they required /
recommended ?
a r r 0 0 0 Continuous
review
None
8.4.8 Are there hose reels present – if
they are not present are they
required / recommended ?
a r r 0 0 0 Continuous
review
None
8.4.9 Are fire blankets present – if they
are not present are they required
/ recommended ?
a r r 0 0 0 Continuous
review
None
8.4.10 Are there portable fire
extinguishers present – if they are
not present are they required /
recommended ?
a r r 0 0 0 Continuous
review
None
8.4.11 Are the portable fire
extinguishers clearly visible and
accessible with correct signage?
a r r 0 0 0 Continuous
review
None
8.4.14 Are the Portable Fire
Extinguishers suitable & sufficient
for purpose?
a r r 0 0 0 Continuous
review
None
8.4.15 Are the Portable Fire
Extinguishers clearly visible and
accessible?
a r r 0 0 0 Continuous
review
None
r
0
UPRNFull AddressDate 21 June 2014
Measures for fire detection and
warning
N/A Yes No
Ris
k Le
vel
(1-5
)
Pro
bab
ilit
y Le
vel (
1-
Rat
ing
(RLx
P) Priority Comments Action
Point
Ref.
8.4.12 Is an automatic fire warning
system present – or if it is not
present is it required or
recommended?
a r r 0 0 0 Continuous
review
None
8.4.13 Is the property classified as a
HMO (House of Multiple
Occupancy) within guidelines of
Lacors and Housing Act
a r r 0 0 0 Continuous
review
None
8.5.1 Does the fire warning system
have a named responsible
person, who has authority and
training to manage the system?
a r r 0 0 0 Continuous
review
None
8.5.2 Is the Automatic Fire Detection /
warning system suitable and
sufficient for the premises?
a r r 0 0 0 Continuous
review
None
8.5.3 Are manual call points suitable
and sufficiently located and
accessible?
a r r 0 0 0 Continuous
review
None
8.5.3 Are sounders/klaxons suitable
and sufficiently located?
a r r 0 0 0 Continuous
review
None
8.5.4 Does the Fire Warning system
have a guaranteed power supply?
a r r 0 0 0 Continuous
review
None
Measures for signs and notices N/A Yes No
Ris
k Le
vel
(1-5
)
Pro
bab
ilit
y Le
vel (
1-
Rat
ing
(RLx
P) Priority Comments Action
Point
Ref.
8.6.1 Are all Fire doors fitted with self
closing devices suitably and
correctly signed
a r r 0 0 0 Continuous
review
None
8.6.2 Are all Fire Doors to stores, and
cupboards suitably and correctly
signed
r a r 0 1 0 Continuous
review
None
8.6.3 Are all final exit doors suitably
and correctly signed
r a r 0 1 0 Continuous
review
None
8.6.4 Are all emergency exits suitably
and correctly signed
r a r 0 1 0 Continuous
review
None
8.6.5 Are all emergency escape routes
suitably and correctly signed?
r a r 0 1 0 Continuous
review
single means of escape from
building
None
8.6.6 Are Lifts ( in case of emergency)
suitably and correctly signed?
a r r 0 0 0 Continuous
review
None
8.6.7 Are Fire Action Notices clearly
displayed?
a r r 0 0 0 Continuous
review
None
8.6.8 Are electrical warnings clearly
displayed
a r r 0 0 0 Continuous
review
None
00
UPRNFull AddressDate 21 June 2014
Measures to assist means of
escape
N/A Yes No
Ris
k Le
vel
(1-5
)
Pro
bab
ilit
y Le
vel (
1-
Rat
ing
(RLx
P) Priority Comments Action
Point
Ref.
8.7.1 Are there a sufficient number of
exits from the building, and are
they of adequate size for the
number of occupants?
r a r 0 1 0 Continuous
review
None
8.7.2 Can all emergency / final exit
doors be opened easily in single
action?
r a r 0 1 0 Continuous
review
None
8.7.3 Do means of escape lead directly
to a place of safety?
r a r 0 1 0 Continuous
review
None
8.7.4 Is the Escape route free from
obstructions, slip or trip hazards?
r a r 0 1 0 Continuous
review
None
8.7.5 Are the travel distances suitable
and sufficient ?
r a r 0 1 0 Continuous
review
None
8.7.6 Are the escape routes suitable
and sufficient for occupants with
impaired mobility ?
r r a 3 4 12 Medium
High Risk
No details provided about
private residents with disabilities
8.7.6
8.7.7 Are the escape routes widths and
capacities suitable and sufficient
?
r a r 0 1 0 Continuous
review
None
8.7.8 Are there alternative exits from
inner rooms or basements?
a r r 0 0 0 Continuous
review
None
8.7.9 Are the exits from external
stairways suitable and sufficient?
a r r 0 0 0 Continuous
review
None
8.7.10 Is the means of escape clear of
the need to use ladders, hatches
or windows?
r a r 0 1 0 Continuous
review
None
8.7.11 Is the Means of Escape suitable
and sufficient to provide 30
minutes fire resistance?
r a r 0 1 0 Continuous
review
None
8.7.12 Is the use of cavity barriers / fire
stopping and dampers evident
within ducts / suspended ceilings
/ floors?
a r r 0 0 0 Continuous
review
None
8.7.13 Is a suitable and sufficient place
of safety (refuge) provided?
a r r 0 0 0 Continuous
review
None
8.7.14 Are defined zones on external
emergency areas of fire resisting
nature, including doors, windows,
and walls?
a r r 0 0 0 Continuous
review
None
8.7.15 Where roof exits are designated
as means of escape is suitable
and sufficient access through the
door available?
a r r 0 0 0 Continuous
review
None
8.7.16 Where roof exits are designated
as means of escape is suitable
and sufficient lighting /
illumination available?
a r r 0 0 0 Continuous
review
None
8.7.17 Where roof exits are designated
as means of escape is the surface
non slip / guarded with a
protective barrier?
a r r 0 0 0 Continuous
review
None
8.7.18 Are all emergency escape routes
suitably illuminated with
emergency lighting?
r r a 3 4 12 Medium
High Risk
borrowed lighting available 8.7.18
8.7.19 Does the Emergency Lighting
system have a back up power
source?
a r r 0 0 0 Continuous
review
None
8.7.20 Do all final exit doors open in the
direction of escape?
r r a 3 4 12 Medium
High Risk
limited occupation less than 60
persons
8.7.20
00
UPRN
Full AddressDate 21 June 2014
Measures of maintenance for
fire safety facilities. Do you
regularly inspect, test, report
and record in a log book the
following?
N/A Yes No
Ris
k Le
vel (
1-5
)
Pro
bab
ility
Leve
l (1-
5)
Rat
ing
(RLx
P) Priority Comments Action
Point
Ref.
8.8.1 All Flat Entrance doors a r r 0 0 0 Continuous
review
None
8.8.2 All Communal doors r a r 0 1 0 Continuous
review
Doors in poor condition and do
not lock securely
None
8.8.3 All Roof Access doors a r r 0 0 0 Continuous
review
None
8.8.4 All intake Cupboard doors r a r 0 1 0 Continuous
review
None
8.8.5 All Store Cupboard doors a r r 0 0 0 Continuous
review
None
8.8.6 Escape Routes r a r 0 1 0 Continuous
review
None
8.8.7 Housekeeping r a r 0 1 0 Continuous
review
None
8.8.8 Compartmentation a r r 0 0 0 Continuous
review
None
8.8.9 Fire Integrity common areas r a r 0 1 0 Continuous
review
None
8.8.10 Emergency Lighting a r r 0 0 0 Continuous
review
None
8.8.11 Fire fighting equipment a r r 0 0 0 Continuous
review
None
8.8.12 Portable Appliances a r r 0 0 0 Continuous
review
None
8.8.13 Electrical installations r r a 3 2 6 Medium
Risk
no evidence of recent Periodic
inspection to electrical system
8.8.13
8.8.14 Fire Alarm / Detection / warning
system
r a r 0 1 0 Continuous
review
None
8.8.15 Fire Extinguishers a r r 0 0 0 Continuous
review
None
8.8.16 Smoke Vents a r r 0 0 0 Continuous
review
None
8.8.17 Sprinklers / Suppression system a r r 0 0 0 Continuous
review
None
8.8.18 Signs & Notices r a r 0 1 0 Continuous
review
None
8.8.19 Dry / Wet Riser a r r 0 0 0 Continuous
review
None
8.8.20 Lightning Conductors a r r 0 0 0 Continuous
review
None
8.8.21 Access levels r a r 0 1 0 Continuous
review
None
8.8.22 Gas Appliances / systems a r r 0 0 0 Continuous
review
None
8.8.23 Air conditioning units a r r 0 0 0 Continuous
review
None
8.8.24 Hose Reels a r r 0 0 0 Continuous
review
None
8.8.25 Fire Blankets a r r 0 0 0 Continuous
review
None
8.8.26 Presence of a log book a r r 0 0 0 Continuous
review
None
0
0
UPRN
Full AddressDate 21 June 2014
Item Measures for management of
information and procedure
N/A Yes No
Ris
k Le
vel
(1-5
)
Pro
bab
ilit
y Le
vel (
1-
Rat
ing
(RLx
P) Priority Comments Action
Point
Ref.
8.9.1 Is a suitable emergency action
plan in place for the purpose of
safeguarding residents, occupants
and other persons present in the
event of a fire?
r r a 5 4 20 High Risk No emergency plans on site or
issued to occupants
8.9.1
8.9.2 Is the plan premise specific and
up to date?
a r r 0 0 0 Continuous
review
None
8.9.3 Is there a fully trained and
equipped warden nominated to
implement the emergency action
plan?
a r r 0 0 0 Continuous
review
None
8.9.4 Are emergency contacts with
external services arranged as
necessary with regards to rescue
work and fire fighting?
r r a 3 4 12 Medium
High Risk
contact is local fire brigade
service
8.9.4
8.9.5 Where two or more organisations
share/manage the premise do
they cooperate as far as
necessary to comply with the
RR(FS)O .
a r r 0 0 0 Continuous
review
None
8.9.6 Have appropriate procedures
been established to evacuate or
restrict access to confined spaces
or hazardous locations?
a r r 0 0 0 Continuous
review
None
8.9.7 Are others who may have caused
to visit or work within the
property provided with
comprehensive information on
the measures taken in
compliance with the RR(FS)O?
r a r 0 1 0 Continuous
review
None
8.9.8 Are occupants on the premise
provided with comprehensive
and relevant information on the
emergency action plan?
r r a 3 4 12 Medium
High Risk
No emergency plans on site or
issued to occupants
8.9.8
8.9.9 Do the occupants know the
identity of those persons
nominated to implement the
emergency action plan?
r r a 3 4 12 Medium
High Risk
No emergency plans on site or
issued to occupants
8.9.9
8.9.10 Is a record of fire or near misses
kept with full details of the
occurrence?
r a r 0 1 0 Continuous
review
None
8.9.11 Are others who may have caused
to visit or work within the
property provided with regular
fire safety training and details of
the training recorded?
r a r 0 1 0 Continuous
review
None
8.9.12 Are regular fire evacuation drills
undertaken and details of these
recorded?
r r a 3 4 12 Medium
High Risk
8.9.12
0
0
UPRNFull AddressDate 21 June 2014
Responsible Team Action to be taken Date
Completed
8.1.3
Are suitable arrangements in
place for the disposal of
“smoking” materials
Evidence that residents
dispose of smoking
materials at entrance
area.
Medium
Risk
1 year Landlord / managing
agent
consider installing
smokers bin
adjacent to the door
8.4.2
Are Fire Hydrants in suitable
proximity of building and
clearly visible?
No visual evidence of
hydrants
High Risk 28 days Landlord / managing
agent
identify and clearly
label the location of
local hydrants to the
site
8.7.6
Are the escape routes
suitable and sufficient for
occupants with impaired
mobility ?
No details provided
about private residents
with disabilities
Medium
High Risk
6 months Landlord / managing
agent
consider reviewing
occupancy types
and include within
emergency action
plan for the building
where necessary
8.7.18Are all emergency escape
routes suitably illuminated
with emergency lighting?
borrowed lighting
available
Medium
High Risk
6 months Landlord / managing
agent
consider installing
emergency lighting
to the building
8.7.20Do all final exit doors open
in the direction of escape?
limited occupation less
than 60 persons
Medium
High Risk
6 months Landlord / managing
agent
nor requried due to
the building
capacity
8.8.13
Electrical installations no evidence of recent
Periodic inspection to
electrical system
Medium
Risk
1 year Landlord / managing
agent
Arrange for a five
yearly inspection of
system to be carried
out
00
Photo
Ref. No.
Action PointAssessment
Guidance
Ref.
Description of Significant
Finding / Item Priority
Target
TimeComment
Significant Findings
Responsible Team Action to be taken Date
Completed
Photo
Ref. No.
Action PointAssessment
Guidance
Ref.
Description of Significant
Finding / Item Priority
Target
TimeComment
Significant Findings
8.9.1
Is a suitable emergency
action plan in place for the
purpose of safeguarding
residents, occupants and
other persons present in the
event of a fire?
No emergency plans on
site or issued to
occupants
High Risk 28 days Landlord / managing
agent
create and distibute
emergency plan for
premise
8.9.4
Are emergency contacts with
external services arranged
as necessary with regards to
rescue work and fire
fighting?
contact is local fire
brigade service
Medium
High Risk
6 months Landlord / managing
agent
no action needed
8.9.8
Are occupants on the
premise provided with
comprehensive and relevant
information on the
emergency action plan?
No emergency plans on
site or issued to
occupants
Medium
High Risk
6 months Landlord / managing
agent
create and distibute
emergency plan for
premise
8.9.9
Do the occupants know the
identity of those persons
nominated to implement the
emergency action plan?
No emergency plans on
site or issued to
occupants
Medium
High Risk
6 months Landlord / managing
agent
create and distibute
emergency plan for
premise
8.9.12
Are regular fire evacuation
drills undertaken and details
of these recorded?
0 Medium
High Risk
6 months Landlord / managing
agent
create and distibute
emergency plan for
premise
Block Fire Risk Assessment Sheet
The below scoring system will determine the overall fire risk profile and frequencyof Fire Risk Assessment review.
Description High Risk Medium Risk Low Risk
1.0 Number of Staircases within the buildingOne Two Three +
1 0 0
2.0Is there a lobby approach to the flat front
doors? No Yes1 0
3.0Have ALL doors to the block been
upgraded? No Some Yes0 1 0
4.0Is Emergency Lighting installed
throughout? No Some Yes1 0 0
5.0Is the Means of Escape kept clear at all
times? No Sometimes Yes0 0 0
6.0How Many fires have occurred within the
block within the past five years? More than 6 2 – 5 fires Zero – 1 fire0 0 1
7.0Are Estate Management issues raised and
managed effectively No Sometimes Yes0 0 1
8.0What is the general layout or nature of the
building and referring to tenancy SAS / Community
centre / caretaker area
General Needs / HMO
designed building
General Needs /
Leaseholder or
converted property0 0 1
9.0How Many Floors are in the block
including basement Over 7 Between 4 - 6 One - three0 0 1
10.0Is there automatic smoke or fire detection
present to the building None at all in building
Some in communal
areas
Full Fire detection
system0 1 0
Scoringpoints added from each column 3 2 4Multiplication factor 3 2 1Sub score 9 4 4
Total score of all columns 17
Findings guide Fire Risk Assessment renewal as follows:
* between 1 and 10 is classified as a low risk building and will have a full fire risk assessment undertaken every five years.
All buildings will have their fire risk assessment reviewed prior and post completion of any major works within the block.
This building has been identified with a block level risk assessment as a building of :
Medium - Renew FRA at least every three years
0021 June 2014
* between 20 and 30 is a high risk building and will have a full fire risk assessment undertaken each year.
* between 10 and 20 is classified as a medium risk building and will have a full fire risk assessment undertaken every three
years.