12
FireNET ® Series - DIGITAL ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL STANDARD FEATURES UL 864 9th Edition Listed Seismic certified Digital Analog design using Hochikis advanced DCP protocol for fast and robust communication Up to 127 sensors & modules, plus 127 digital analog sounder bases, for a total of 254 points possible per loop Uses standard wire, no shielded or twisted pair required on SLC loops Supports Class B (style 4) and Class A (style 6 or 7) SLC loops 4 on board Class B (style Y) NAC circuits rated at 2.5 Amps each Programmable sensitivity levels per device & automatic day/night sensitivity modes Automatic daily calibration & drift compensation routine Large 8-line x 40-character LCD (320 char.) 2 loop (FN-2127 Series) or 4 loop (FN-4127 Series) versions (800 addresses/sub-addr. max.) Dual RS-485 bus for panel network 2 built-in RS-232 interfaces for programming via a PC and serial printer interface 5 on board programmable Form C relays rated at 1 amp at 30VDC (Fire1, Fire2, trouble, supervisory, aux.) 500mA of auxiliary power available rated at 24 VDC Loop Explorer Windows® configuration utility 500 network wide software zones Network capability of up to 64 panels RS485 slave bus for expansion - up to 32 FN-4127-IO boards or up to 15 FN-LCD-S serial annunciators and up to 17 FN-4127-IO boards Auto-learn feature Fire Drill test function Walk test function Alarm verification feature FireNET ® is UL listed for Central Station Service, Remote Station Service and Proprietary Service Operates on 120VAC or 240VAC input voltage Powerful & versatile Cause & Effect programming (up to 500 maximum, network wide) including: *Cause & Effect action *Disable function configuration *Test mode configuration UL 864, Local Signaling Unit. Types: Automatic, manual, waterflow, sprinkler supervisory, Remote Station and Central Station Service (DACT) Non-coded signaling. NFPA 70, 72 &13 Compliant S6468 California State Fire Marshal 7165-0410:159 3033817 Hochiki America Corporation 7051 Village Drive, Suite 100 Buena Park, CA 90621-2268 Phone: 714-522-2246 Fax: 714-522-2268 Technical Support: 800-845-6692 or [email protected] Find latest revision at www.hochiki.com F0068 Rev.1 07/2017 DESCRIPTION The FireNET ® 4127 control panel is an digital analog address-able fire alarm panel containing 2 or 4 SLC loops with each loop supporting 127 devices of any combination (sensors or modules), and 127 digital analog sounder bases, for a possible total of 254 points. Communication between devices is transferred through standard cable (shielded or twisted pair is not required). Each panel includes a 5.25 amp power supply and has 4 on board NAC circuits. An RS-485 bus provides communication to the panel network, while the RS-232 interface allows the convenience of programming via a PC. The system will support a variety of Hochiki devices such as photo, ion and heat sensors, which contain a unique, patented sensor design incorporating automatic drift compensation and day/night sensitivity mode. Additional devices include contact monitors, relay controllers, supervised auxiliary output and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone-monitoring module. The Loop Explorer Windows ® Software interface provides the installer with fingertip access to installation programming and diagnostic tools. An Auto-learn feature offers the convenience for quick start applica- tions. Add to this Hochiki's reputation for high quality and dedicated service, and you have an exceptional product with performance and value. PRODUCT LISTINGS Specifications subject to change without notice.

FireNET Series DIGITAL ANALOG ADDRESSABLE FIRE ALARM

  • Upload
    others

  • View
    19

  • Download
    0

Embed Size (px)

Citation preview

Page 1: FireNET Series DIGITAL ANALOG ADDRESSABLE FIRE ALARM

FireNET®

Series - DIGITAL ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

STANDARD FEATURES

• UL 864 9th Edition Listed

• Seismic certified

• Digital Analog design using Hochiki’s advanced DCPprotocol for fast and robust communication

• Up to 127 sensors & modules, plus 127 digital analogsounder bases, for a total of 254 points possible perloop

• Uses standard wire, no shielded or twisted pairrequired on SLC loops

• Supports Class B (style 4) and Class A (style 6 or 7)SLC loops

• 4 on board Class B (style Y) NAC circuits rated at 2.5Amps each

• Programmable sensitivity levels per device &automatic day/night sensitivity modes

• Automatic daily calibration & drift compensationroutine

• Large 8-line x 40-character LCD (320 char.)

• 2 loop (FN-2127 Series) or 4 loop (FN-4127 Series)versions (800 addresses/sub-addr. max.)

• Dual RS-485 bus for panel network

• 2 built-in RS-232 interfaces for programming via a PCand serial printer interface

• 5 on board programmable Form C relays rated at1 amp at 30VDC (Fire1, Fire2, trouble, supervisory,aux.)

• 500mA of auxiliary power available rated at 24 VDC

• Loop Explorer Windows® configuration utility

• 500 network wide software zones

• Network capability of up to 64 panels

• RS485 slave bus for expansion - up to 32FN-4127-IO boards or up to 15 FN-LCD-S serialannunciators and up to 17 FN-4127-IO boards

• Auto-learn feature

• Fire Drill test function

• Walk test function

• Alarm verification feature

• FireNET® is UL listed for Central Station Service,

Remote Station Service and Proprietary Service

• Operates on 120VAC or 240VAC input voltage

• Powerful & versatile Cause & Effect programming(up to 500 maximum, network wide) including:

*Cause & Effect action*Disable function configuration*Test mode configuration

UL 864, Local Signaling Unit. Types: Automatic, manual, waterflow, sprinkler supervisory, Remote Station and Central Station Service (DACT) Non-coded signaling. NFPA 70, 72 &13 Compliant

S6468

California State Fire Marshal 7165-0410:159 3033817

Hochiki America Corporation

7051 Village Drive, Suite 100 Buena Park, CA 90621-2268

Phone: 714-522-2246 Fax: 714-522-2268

Technical Support: 800-845-6692 or [email protected]

Find latest revision at www.hochiki.com

F0068 Rev.1 07/2017

DESCRIPTION

The FireNET® 4127 control panel is an digital analog

address-able fire alarm panel containing 2 or 4 SLC loops with each loop supporting 127 devices of any combination (sensors or modules), and 127 digital analog sounder bases, for a possible total of 254points. Communication between devices is transferred through standard cable (shielded or twisted pair is not required). Each panel includes a 5.25 amp power supply and has 4 on board NAC circuits. An RS-485 bus provides communication to the panel network, while the RS-232 interface allows the convenience of programming via a PC.

The system will support a variety of Hochiki devices such as photo, ion and heat sensors, which contain a unique, patented sensor design incorporating automatic drift compensation and day/night sensitivity mode. Additional devices include contact monitors, relay controllers, supervised auxiliary output and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a conventional zone-monitoring module.

The Loop Explorer Windows® Software interface

provides the installer with fingertip access to installation programming and diagnostic tools. An Auto-learn feature offers the convenience for quick start applica-tions. Add to this Hochiki's reputation for high quality and dedicated service, and you have an exceptional product with performance and value.

PRODUCT LISTINGS

Specifications subject to change without notice.

Page 2: FireNET Series DIGITAL ANALOG ADDRESSABLE FIRE ALARM

Hochiki America Corporation FireNET DIGITAL ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL Specifications subject to change without notice.

FireNET® Series - DIGITAL ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

SPECIFICATIONS

Primary AC 120VAC @ 2.1 Amps 60hz or 220VAC @ 1.1Amps 50hz

Output DC 24VDC @ 5.25 Amps (4 Amps available for system power)

Power Supply 5.25 Amps integrated

Charger Current 1.5 Amps max.

Dimensions 14.5" W x 24" H x 5" D

Weight 31 lbs. (without batteries)

Color Red (optional gray)

Material ABS/steel enclosure

Display 8 line x 40 character LCD (320 characters total)

Network Dual RS485 ports (64 panels max.)

Zones 500 network wide software zones per system

SLC loops 2 or 4 (class A, "style 6 or 7" or class B, "style 4")

Devices per loop 127 sensors & modules, plus 127 digital analog sounder bases, 254 total

Addresses per panel (800 addresses+sub-addresses max. per panel)

NAC Outputs (4) 2.5 Amps @ 24VDC (class B)

Relay Outputs (5) Form C 1 Amp @ 30VDC

Voltage Outputs (3) 500mA @ 24VDC

Aux. Power 500mA @ 24VDC

Aux. Inputs (8) digital pull downs

PC Port / Printer RS232

Operating Temp. 32°F (0°C) 120°F (49°C)

Relative Humidity 85% RH Non-Condensing

MODEL DESCRIPTION

FN2127US0ERS120 2015 Ed. FireNET® FACP, 2 Loop, Red, 120V

FN4127US0ERS120 2015 Ed. FireNET® FACP, 4 Loop, Red, 120V

FN2127US1ERS120 2015 Ed. FireNET® FACP, 2 Loop, W/Network Card, Red, 120V

FN4127US1ERS120 2015 Ed. FireNET® FACP, 4 Loop, W/Network Card, Red, 120V

FN-2127US0ERS-220 2015 Ed. FireNET® FACP, 2 Loop, Red, 220V

FN-4127US0ERS-220 2015 Ed. FireNET® FACP, 4 Loop, Red, 220V

FN-2127US1ERS-220 2015 Ed. FireNET® FACP, 2 Loop, W/Network Card, Red, 220V

FN-4127US1ERS-220 2015 Ed. FireNET® FACP, 4 Loop, W/Network Card, Red, 220V

SLC COMPATIBLE DEVICES & SYSTEM ACCESSORIES

CONTROL PANEL EXPANDERS

FN-4127-SLC Dual SLC Loop Expansion Card

FN-4127-NIC Network Interface Card

FN-4127-IO 16 16 Channel Input/Output Board

FN-DAC Digital Alarm Communicator

FN-CTM City-Tie Module (Local Energy Type)

ANNUNCIATOR

FN-LCD-N Network LCD Annunciator

FN-LCD-S Serial LCD Annunciator

SLC LOOP DEVICES

ALG-V, ALK-V, ALN-V Digital Analog Addressable Photoelectric Sensor

AIE-EA Digital Analog Addressable Ionization Sensor

ATG-EA, ATJ-EA Digital Analog Addressable Heat Sensor

ACA-V, ACC-V Multi-criteria Sensor

NSA-4 & NSA-6 Four Inch Sensor Base and Six Inch Sensor Base

SCI-B4 & SCI-B6 Four Inch Short Circuit Isolator Digital Analog Sensor Base & Six Inch Circuit Isolator Digital Analog Sensor Base

ASB Digital Analog Sounder Base

ASBL Digital Analog Low Frequency Sounder Base

DH-98A, DH-98AR, DH-99A, DH-99AR Digital Analog Addressable Duct Detector Unit (DH-98AR and DH-99AR have relays built-in)

MS-RA, MS-RA/R, MS-KA/R Remote Test Station for DH-98AR & DH-99AR

DCP-FRCME-M Contact Monitoring Module (mini w/terminal blocks)

DCP-FRCME-P Contact Monitoring Module (mini w/pigtail leads)

DCP-FRCME-4 Contact Monitoring Module (with faceplate/indicating LED)

DCP-FRCMA, DCP-FRCMA-I Class A Contact Monitoring Module (FRCMA-I has built-in SCI)

DCP-DIMM Dual Input Monitor Module (with faceplate/indicating LED)

DCP-CZM Conventional Zone Module

DCP-R2M Dual Relay Module

DCP-R2ML/H Series Dual Relay Module (R2ML-I & R2MH-I has built-in SCI)

DCP-SOM Supervised Output Module

DCP-SOM-A, DCP-SOM-AI Class A Supervised Output Module (SOM-AI has built-in SCI)

DCP-SOM-R Supervised Output Module for Releasing Pre-action System

DCP-SCI Short Circuit Isolator Module

DCP-AMS Series Addressable Manual Pull Station

ACCESSORIES

TCH-B100 Hand Held Programmer (portable device addresser)

FN-ACC Battery/Accessory Enclosure (houses up to 33AH size batteries)

FNP-ETR Enclosure Trim Ring for panel flush mount

FIRENET® ORDERING MODELS

Page 3: FireNET Series DIGITAL ANALOG ADDRESSABLE FIRE ALARM

FireNET L@TITUDE - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

STANDARD FEATURES

UL Listed (10th Edition), FM and CSFM Approved

2 to 8 loop or 2 to 16 loop versions

400mA loop current

Programmable NACs; 4 Class B or 2 Class A, all with internal synchronization

5.25 A or 10.25 A power supply options

3 programmable inputs and 5 programmable relay outputs

7 inch, full-color resistive touch screen with intuitive user interface

Up to 24 programmable soft “function keys”

Up to 64 user login accounts

Hard-wired fire and trouble routing inputs and out-puts

Modular and expandable electronics

400 subaddress points per loop (800 per loop mod-ule)

Option to “invert” inputs and outputs

5,000 programmable cause and effects; over 50,000 inputs and outputs

Can be networked with programmable functionality

Programming via USB port to PC or memory stick

L@ti-View Graphical PC User Interface - coming soon!

Hochiki America Corporation

7051 Village Drive, Suite 100, Buena Park, CA 90621-2268

Phone: 714-522-2246 Fax: 714-522-2268

Technical Support: 800-845-6692 or [email protected]

Find latest revision at www.hochiki.com

Page 1 of 4 F0224 Rev3 09/2021

DESCRIPTION

The all new L@titude product range of fire alarm control equipment combines the very latest hardware and software to produce a control and indication system, which is powerful and sophisticated, yet simple to use and understand. The flexibility of the L@titude platform is such that it can be re-configured to realize many other control and indication applications, with direct integration into intelligent buildings.

Moving away from the simple, price driven competitive model used by most manufacturers today, the L@titude concept is designed to add value to System Designers, Integrators, Service Providers, and end users. Devel-oped from the “ground up” and using some of the most advanced technology available, L@titude is designed as one of the most powerful, intelligent, and technically robust fire alarm products available.

Not only do the products and services offered under the L@titude brand provide solutions to the most technically challenging applications in life safety, L@titude will de-liver added value, market advantage, and a competitive edge to your business.

PRODUCT LISTINGS

Specifications subject to change without notice.

Manufactured by Kentec Electronics Ltd.

Dartford, DA11JQ, United Kingdom

California State

Fire Marshal

7165-0410:0506

Page 4: FireNET Series DIGITAL ANALOG ADDRESSABLE FIRE ALARM

FireNET L@TITUDE - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

Optional Panel Peripherals • Dual Loop Panel Module (S758) The Dual Loop Panel Module monitors loop device status and provides status to the panel processor. It holds device configurations and operates in a standalone manner when catastrophic failures occur. • 16 Channel I/O Interface Card (K6006) The 16 Channel I/O Interface enhances the versatility of the alarm system by providing additional input and output capabilities to the L@titude Fire Alarm Control Panel. In-puts or outputs can be selected for up to 16 individual channels, and are configured in the same way as devices connected to addressable loops of the panel. The 16 Channel I/O Interface can be configured to contribute or act upon cause and effect logic. • Media Gateway™ Panel Module (S788) The Media Gateway™ Panel Module provides connectivity to monitoring centers using IP (Sur-Gard), or dialup con-nectivity. The Media Gateway™ may also be used to meet integration application requirements. • 8 Channel Relay Panel Module (S791) The 8 Channel Relay Panel Module has 8 voltage-free changeover relay contacts, each of which can be individu-ally programmed. All outputs are configurable in the same way as devices connected to the loops and all may be acted upon by cause and effect logic. These boards are typically used in applications which require more than the five standard relay outputs, such as signaling to other sys-tems or plant control. • Network Module (S723) The L@titude Network Module provides enhanced high-speed communication for networking fire control panels. The network provided by this module can support combi-nations of L@titude Fire Alarm Control Panels and L@titude Vision units. L@titude Fire Alarm Control Panels can receive events from other panels in the network. The Class X networking used in conjunction with the Network Module provides tolerance against open and short circuit trouble conditions.

• Printer (S768) The L@titude Printer is an optional feature for printing fire system events as they occur. The printer is located on the fascia, below the Zone LEDs (if present). It is a thermal printer and never requires replacement ink. Printing is per-formed on heat-sensitive paper rolls. A trouble message is reported when the paper runs out. The printer includes a front-loading feature for replacing paper rolls. • Zone LED Module (S771) The Zone LED module contains 48 LEDs and is connected to the LCD Main Processor Board of the L@titude Fire Alarm Control Panel. A maximum of three Zone LED mod-ules can be connected to provide the fascia with 144 Zone LED indicators. • 4 Channel NAC Panel Module (S793) FUTURE ENHANCEMENT Additional NAC output capability can be added to by using 4 Channel NAC Modules. These boards have 4 super-vised NAC outputs, each of which can be individually pro-grammed. The circuits can be configured for class A or B operation. These circuits can be configured to act upon cause and effect logic. • 8 Channel Conventional Zone Panel Module (S792) FUTURE ENHANCEMENT The 8 Channel Conventional Zone Panel Module has 8 supervised detection circuits (Class B). Each circuit can support up to 20 conventional detectors and approved devices. Individual circuits may be configured for trigger resistor or short circuit activation. These circuits may be used for any of the standard input actions and can be con-figured to contribute to cause and effect logic. Each pair of circuits (e.g., 1 and 2, 3 and 4, etc.) can be joined to form a single Class A configuration. • 16 Channel I/O Interface Panel Module (S772) FUTURE ENHANCEMENT The 16 Channel I/O Interface Panel Module will provide the same functionality as the 16 Channel I/O Interface Card, with the convenience of a plug-in-module.

Hochiki America Corporation FireNET L@TITUDE ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL Page 2 of 4 Specifications subject to change without notice.

Single Aperture Double Aperture Includes Zone LED Module and Printer

Page 5: FireNET Series DIGITAL ANALOG ADDRESSABLE FIRE ALARM

TECHNICAL SPECIFICATIONS

2 to 8 LOOP (4 SLOT) ENCLOSURE

Size Standard Cabinet - 420mm (W) x 590mm (H) x 153mm (D), or 16.5in (W) x 23.2in (H) x 6in (D)

Deep Cabinet - 420mm (W) x 590mm (H) x 203mm (D), or 16.5in (W) x 23.2in (H) x 8in (D)

Construction Mild sheet steel enclosure, 1.5mm, 16 gauge

Cable Entry Standard Cabinet - 28 knockouts top, 19 knockout back, 1 knockout each side, 2 knockout bottom Deep Cabinet - 38 knockouts top, 19 knockout back, 1 knockout each side, 2 knockout bottom

Optional Semi-Flush Mounting Kit Semi-Flush Mounting Collar Kit

KM5FCRD - Red

KM5FCGY - Gray

KM5FCBS - Black

Battery Capacity Standard Cabinet - Up to 28 Ah (Power Sonic PS-12280)

Deep Cabinet - Up to 40 Ah (Power Sonic PS-12400)

2 to 16 LOOP (8 SLOT) ENCLOSURE

SIZE 8 Slot Standard Cabinet - 540mm (W) x 720mm (H) x 160mm (D), or 21.3in (W) x 28.3in (H) x 6.3in (D)

8 Slot Deep Cabinet - 540mm (W) x 720mm (H) x 212mm (D), or 21.3in (W) x 28.3in (H) x 8.3in (D)

Construction Mild sheet steel enclosure, 1.5mm, 16 gauge

Cable Entry Standard Cabinet - 38 knockouts top, 25 knockout back, 2 knockout each side, 2 knockout bottom Deep Cabinet - 50 knockouts top, 25 knockout back, 2 knockout each side, 2 knockout bottom

Battery Capacity Standard Cabinet - Up to 28 Ah (Power Sonic PS-12280)

Deep Cabinet - Up to 40 Ah (Power Sonic PS-12400)

ALL MODELS

Finish Epoxy powder coated

Color Lid & Box - Red, Gray or Black

Control Plate - RAL7016

Power supply voltage 120 V AC or 240 V AC

Power supply rating at 24V DC 5.25 A (charges up to 60 Ah)

10.25 A (charges up to 100Ah)

Display Full color 800 x 480 LCD with resistive touch screen and automatic backlight dimming

Software zones 2,000

Software groups 5,000

Cause and Effects 5,000

Event log 10,000 events, 1 second resolution. Filterable and printable

Detection loops 2 to 16 added 2 at a time (S758 dual loop cards)

Detection loop current 400 milliamps each

AUX 24V Output 2; each rated at 900 mA

NACs 4; each rated at 2.5A (1.3A for System Sensor devices). Class B or 2 Class A

Programmable Relay Outputs 5; 30 V DC 1 Amp

Programmable Inputs 3; designed to be activated by voltage-free contacts

Network Connections Optional network card provides communication for networking 127 fire control panels

NAC Synchronization Internal Support of System Sensor, Wheelock, Gentex and Amseco protocols

Printer

(OPTIONAL)

40 column, front-loading thermal

Zone LED Indicators

(OPTIONAL)

Up to 3 banks of 48 (144) as standard

Maximum Number of Nodes on a Network

64

FireNET L@TITUDE - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

ELECTRICAL SPECIFICATIONS PART NUMBER MODEL NAME STANDBY CURRENT ALARM CURRENT NOTES

See Below *L@titude Control Panel .350A .450A

See Below Vision Annunciator .341A .341A

0101-02710 S408 10.25A Power Supply .080A .080A

0101-02690 S406 5.25A Power Supply .078A .078A

0101-01220 S723 Network Module .080A .080A

0101-01230 S758 Dual Loop Module .115A .115A Figures exclude SLC devices

0101-01280 S788 Media Gateway Module .114A .114A

0101-01250 S791 8-Channel Relay Module .010A .160A Alarm all 8 relays active

0101-01330 S771 Zone LED Module .005A .005A +.003A per active LED

0101-01290 S768 Thermal Printer .000A 1.500A

*Current draw includes LCD main processor board, main back board, System A board, and System B boards only*

Hochiki America Corporation FireNET L@TITUDE ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL Page 3 of 4 Specifications subject to change without notice.

Page 6: FireNET Series DIGITAL ANALOG ADDRESSABLE FIRE ALARM

FireNET L@TITUDE - ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

Panel Options Valid Entries Description

Product Style LA FireNET L@titude

LF FireNET L@titude Vision Repeater

Enclosure Style

1 4 Slot Standard Enclosure

2 4 Slot Standard Plex-Door Enclosure

3 4 Slot Deep Enclosure

4 4 Slot Deep Plex-Door Enclosure

5 4 Slot Extra Deep Guard Station Enclosure - FUTURE ENHANCEMENT

6 4 Slot 19” Rack Mount Enclosure - FUTURE ENHANCEMENT

7 8 Slot Standard Enclosure - 16 Loop

8 8 Slot Standard Plex-Door Enclosure - 16 Loop

9 8 Slot Deep Enclosure - 16 Loop

A 8 Slot Deep Plex-Door Enclosure - 16 Loop

C Annunciator

Language

0 English

1 Portuguese

2 Spanish

3 Taiwanese

Power Supply

0 None

1 5.25 A 120V

2 5.25 A 240V

3 10.25 A (auto-voltage sensing)

Loop Modules & Communication Modules

00 Not Fitted

NC Network Module only (Network Vision Annunciator)

H# 2-Loop Panel Module, Hochiki Protocol

I# 2-Loop Panel Module, Hochiki Protocol, and Media Gateway™

J# 2-Loop Panel Module, Hochiki Protocol, and Network Module

K# 2-Loop Panel Module, Hochiki Protocol, Network Module, and Media Gateway™

Cabinet Color

1 Red (RAL3002)

4 Gray (BS 00 A 05)

6 Black (RAL9005)

Printer, Zone LEDs & Aperture

0 No Printer / No Zone LEDs

1 No Printer / No Zone LEDs, Blank 2nd Aperture

3 Printer / No Zone LEDs

4 Printer / 48 Zone LEDs

5 No Printer / 48 Zone LEDs

6 No Printer / 96 Zone LEDs

7 No Printer / 144 Zone LEDs

Optional Peripheral Cards

a 16 Channel I/O Panel Module (S772) - FUTURE ENHANCEMENT

b 8 Channel Relay Panel Module (S791)

c 8 Channel Conventional Zone Module (S792) - FUTURE ENHANCEMENT

d 4 Channel NAC Module (S793) - FUTURE ENHANCEMENT

Hochiki America Corporation FireNET L@TITUDE ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL Page 4 of 4 Specifications subject to change without notice.

Page 7: FireNET Series DIGITAL ANALOG ADDRESSABLE FIRE ALARM

FireNET Plus® - DIGITAL ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

STANDARD FEATURES

• Digital Analog design using Hochiki’s advanced DCPprotocol for fast and robust communication

• Up to 127 sensors & modules, plus 127 Digital Analogsounder bases, for a total of 254 points possible per loop

• Uses standard wire, no-shielded or twisted pair required onSLC loops

• Integrated digital alarm communicator (DACT) with ContactID and SIA reporting formats (optional)

• Programmable sensitivity levels by device

• Alarm verification feature

• Automatic daily calibration & drift compensation routine

• Large 8-line x 40-character LCD (320 char.)

• 1 SLC (2nd SLC optional)

• RS-485 bus for panel networking (option)

• Built-in RS-232 interface for programming via a PC

• 3 on board programmable Form C relays rated at 1 amp at30VDC

• 2 auxiliary power outputs, each rated 360mA at 24 VDC

• Loop Explorer Windows® configuration utility

• Auto-learn feature

• 500 network wide software zones

• Network capability of up to 64 panels (option)

• Built in help and alarm information screens

• 2 on-board Class B (style Y) NAC circuits rated at 2.3 ampseach (special application) and 1.6 amps each(regulated continuous)

• Gentex, System Sensor, Wheelock, and Amseco NAC syncprotocol built-in

• Automatic day/night sensitivity modes

• Fire Drill test function

• Walk test function

• Powerful & versatile Cause & Effect wizard including:

° Cause & Effect action

° Disable function configuration

° Test mode configuration

• Seismic certified

Hochiki America Corporation

7051 Village Drive, Suite 100, Buena Park, CA 90621-2268

Phone: 714-522-2246 Fax: 714-522-2268

Technical Support: 800-845-6692 or [email protected]

Find latest revision at www.hochiki.com

F0087 02/2018

S6468

PRODUCT LISTINGS

California State

Fire Marshal

7165-0410:180

DESCRIPTION

The FireNET Plus® 1127 series control panel is a

digital analog addressable fire alarm panel with buildoptions containing 1 or 2 SLC loops, a Digital Alarm Communi-cator/Transmitter (DACT), and an RS-485 bus for network communication. Each SLC loop supports 127 devices of any combination (sensors or modules), and 127 digital analog sounder bases, for apossible total of 254 points per loop. Communication between devices is accomplished by use of standard cable (shielded or twisted pair is not required). Each panel includes a 4-amp power supply and has 2 onboard NAC circuits. The RS-485 bus provides communication to the panel network while another RS-485 bus provides communi-cation for peripheral devices. The RS-232 interface allows the convenience of programming via a PC.

The system will support a variety of Hochiki devices such as photo, ion and heat sensors, which contain a unique, patented sensor design incorporating automatic drift compensation and day/night sensitivity modes. Additional devices include contact monitors, relay con-trollers, supervised auxiliary output and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a con-ventional zone-monitoring module.

The Loop Explorer Windows® Software interface pro-

vides the installer with fingertip access to installation programming and diagnostic tools. An Auto Learn fea-ture offers the convenience for quick start applications. Add to this Hochiki's reputation for high quality and dedicated service, and you have an exceptional product with performance and value.

Specifications subject to change without notice.

3038713

UL 864, Local Signaling Unit.

Types: Automatic, manual,

waterflow, sprinkler supervisory,

Remote Station and Central

Station Service (DACT)

Non-coded signaling.

NFPA 70, 72 &13 Compliant

Page 8: FireNET Series DIGITAL ANALOG ADDRESSABLE FIRE ALARM

Primary AC 120VAC @ 2.1 Amps 50/60hz or 220VAC @ 1.1Amps 50/60hz

Output DC 24VDC @ 5.25 Amps

Power Supply 4 Amp integrated

Charger Current 1.25 Amps max.

Dimensions 14.5” W x 19” H x 3.5” D

Weight 20 lbs. (without batteries)

Color Red (optional gray)

Material ABS/steel enclosure

Display 8 line x 40 character LCD (320 character total)

Network Dual RS485 ports (64 panels max.)

Zones 500 network wide software zones per system

SLC loops 1 or 2 (class A, “style 6 or 7” or class B, “style 4”)

Devices per loop 127 sensors & modules, plus 127 digital analog sounder bases, 254 total

Addresses per panel 800 addresses + sub-addresses max. per panel

NAC Outputs (2) class B, 2.3 Amps (special application)

1.6 Amps Regulated (continuous)

Relay Outputs (3) Form C 1 Amp @ 30VDC

Aux. Power 2 outputs, 360mA @ 24VDC each

PC Port / Printer RS232

DACT Formats Contact ID and SIA

SLC COMPATIBLE DEVICES & SYSTEM ACCESSORIES MODEL DESCRIPTION

CONTROL PANEL EXPANDERS FNP-1127-SLC SLC One Loop Expansion Card

FN-4127-NIC Network Interface Card

FN-4127-IO 16 Channel Input/Output Board ANNUNCIATOR

FN-LCD-S Serial LCD Annunciator

FNP-LED Graphix Display

SLC LOOP DEVICES

ALG-V, ALK-V, ALN-V Digital Analog Addressable Photoelectric Sensor

AIE-EA Digital Analog Addressable Ionization Sensor

ATG-EA, ATJ-EA Digital Analog Addressable Heat Sensor

ACA-V, ACC-V, ACD-V Multi-criteria Sensor

NSA-4 & NSA-6 Four Inch Sensor Base and Six Inch Sensor Base

SCI-B4 & SCI-B6 Four Inch Short Circuit Isolator Digital Analog Sensor Base &

Six Inch Circuit Isolator Digital Analog Sensor Base

ASB Digital Analog Sounder Base

ASBL Digital Analog Low Frequency Sounder Base

DH-98A, DH-98AR

DH-99A, DH-99AR

Digital Analog Addressable Duct Detector Unit

(DH-98AR and DH-99AR have relays built-in)

MS-RA, MS-RA/R, MS-KA/R Remote Test Station for DH-98AR & DH-99AR

DCP-FRCME-M Contact Monitoring Module (mini w/terminal blocks)

DCP-FRCME-P Contact Monitoring Module (mini w/pigtail leads)

DCP-FRCME-4 Contact Monitoring Module (with faceplate/indicating LED)

DCP-FRCMA, DCP-FRCMA-I Class A Contact Monitoring Module (FRCMA-I has built-in SCI)

DCP-DIMM Dual Input Monitor Module (with faceplate/indicating LED)

DCP-CZM Conventional Zone Module

DCP-R2M Dual Relay Module

DCP-R2ML/H Series Dual Relay Module (R2ML-I & R2MH-I has built-in SCI)

DCP-SOM Supervised Output Module

DCP-SOM-A, DCP-SOM-AI Class A Supervised Output Module (SOM-AI has built-in SCI)

DCP-SOM-R Supervised Output Module for Releasing Pre-action System

DCP-SCI Short Circuit Isolator Module

DCP-AMS Series Addressable Manual Pull Station

ACCESSORIES TCH-B100 Hand Held Programmer (portable device addresser)

FN-ACC Battery/Accessory Enclosure (houses up to 33AH size batteries)

FNP-ETR Enclosure Trim Ring for panel flush mount

Hochiki America Corporation FireNET DIGITAL ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL Specifications subject to change without notice.

FireNET Plus® - DIGITAL ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

SPECIFICATIONS

Page 9: FireNET Series DIGITAL ANALOG ADDRESSABLE FIRE ALARM

FireNET Plus® - DIGITAL ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

STANDARD FEATURES

• Digital Analog design using Hochiki’s advanced DCPprotocol for fast and robust communication

• Up to 127 sensors & modules, plus 127 Digital Analogsounder bases, for a total of 254 points possible per loop

• Uses standard wire, no-shielded or twisted pair required onSLC loops

• Integrated digital alarm communicator (DACT) with ContactID and SIA reporting formats (optional)

• Programmable sensitivity levels by device

• Alarm verification feature

• Automatic daily calibration & drift compensation routine

• Large 8-line x 40-character LCD (320 char.)

• 1 SLC (2nd SLC optional)

• RS-485 bus for panel networking (option)

• Built-in RS-232 interface for programming via a PC

• 3 on board programmable Form C relays rated at 1 amp at30VDC

• 2 auxiliary power outputs, each rated 360mA at 24 VDC

• Loop Explorer Windows® configuration utility

• Auto-learn feature

• 500 network wide software zones

• Network capability of up to 64 panels (option)

• Built in help and alarm information screens

• 2 on-board Class B (style Y) NAC circuits rated at 2.3 ampseach (special application) and 1.6 amps each(regulated continuous)

• Gentex, System Sensor, Wheelock, and Amseco NAC syncprotocol built-in

• Automatic day/night sensitivity modes

• Fire Drill test function

• Walk test function

• Powerful & versatile Cause & Effect wizard including:

° Cause & Effect action

° Disable function configuration

° Test mode configuration

• Seismic certified

Hochiki America Corporation

7051 Village Drive, Suite 100, Buena Park, CA 90621-2268

Phone: 714-522-2246 Fax: 714-522-2268

Technical Support: 800-845-6692 or [email protected]

Find latest revision at www.hochiki.com

F0087 02/2018

S6468

PRODUCT LISTINGS

California State

Fire Marshal

7165-0410:180

DESCRIPTION

The FireNET Plus® 1127 series control panel is a

digital analog addressable fire alarm panel with buildoptions containing 1 or 2 SLC loops, a Digital Alarm Communi-cator/Transmitter (DACT), and an RS-485 bus for network communication. Each SLC loop supports 127 devices of any combination (sensors or modules), and 127 digital analog sounder bases, for apossible total of 254 points per loop. Communication between devices is accomplished by use of standard cable (shielded or twisted pair is not required). Each panel includes a 4-amp power supply and has 2 onboard NAC circuits. The RS-485 bus provides communication to the panel network while another RS-485 bus provides communi-cation for peripheral devices. The RS-232 interface allows the convenience of programming via a PC.

The system will support a variety of Hochiki devices such as photo, ion and heat sensors, which contain a unique, patented sensor design incorporating automatic drift compensation and day/night sensitivity modes. Additional devices include contact monitors, relay con-trollers, supervised auxiliary output and short circuit isolator modules. In addition, interfaces to conventional detection systems can be established by using a con-ventional zone-monitoring module.

The Loop Explorer Windows® Software interface pro-

vides the installer with fingertip access to installation programming and diagnostic tools. An Auto Learn fea-ture offers the convenience for quick start applications. Add to this Hochiki's reputation for high quality and dedicated service, and you have an exceptional product with performance and value.

Specifications subject to change without notice.

3038713

UL 864, Local Signaling Unit.

Types: Automatic, manual,

waterflow, sprinkler supervisory,

Remote Station and Central

Station Service (DACT)

Non-coded signaling.

NFPA 70, 72 &13 Compliant

Page 10: FireNET Series DIGITAL ANALOG ADDRESSABLE FIRE ALARM

Primary AC 120VAC @ 2.1 Amps 50/60hz or 220VAC @ 1.1Amps 50/60hz

Output DC 24VDC @ 5.25 Amps

Power Supply 4 Amp integrated

Charger Current 1.25 Amps max.

Dimensions 14.5” W x 19” H x 3.5” D

Weight 20 lbs. (without batteries)

Color Red (optional gray)

Material ABS/steel enclosure

Display 8 line x 40 character LCD (320 character total)

Network Dual RS485 ports (64 panels max.)

Zones 500 network wide software zones per system

SLC loops 1 or 2 (class A, “style 6 or 7” or class B, “style 4”)

Devices per loop 127 sensors & modules, plus 127 digital analog sounder bases, 254 total

Addresses per panel 800 addresses + sub-addresses max. per panel

NAC Outputs (2) class B, 2.3 Amps (special application)

1.6 Amps Regulated (continuous)

Relay Outputs (3) Form C 1 Amp @ 30VDC

Aux. Power 2 outputs, 360mA @ 24VDC each

PC Port / Printer RS232

DACT Formats Contact ID and SIA

SLC COMPATIBLE DEVICES & SYSTEM ACCESSORIES MODEL DESCRIPTION

CONTROL PANEL EXPANDERS FNP-1127-SLC SLC One Loop Expansion Card

FN-4127-NIC Network Interface Card

FN-4127-IO 16 Channel Input/Output Board ANNUNCIATOR

FN-LCD-S Serial LCD Annunciator

FNP-LED Graphix Display

SLC LOOP DEVICES

ALG-V, ALK-V, ALN-V Digital Analog Addressable Photoelectric Sensor

AIE-EA Digital Analog Addressable Ionization Sensor

ATG-EA, ATJ-EA Digital Analog Addressable Heat Sensor

ACA-V, ACC-V, ACD-V Multi-criteria Sensor

NSA-4 & NSA-6 Four Inch Sensor Base and Six Inch Sensor Base

SCI-B4 & SCI-B6 Four Inch Short Circuit Isolator Digital Analog Sensor Base &

Six Inch Circuit Isolator Digital Analog Sensor Base

ASB Digital Analog Sounder Base

ASBL Digital Analog Low Frequency Sounder Base

DH-98A, DH-98AR

DH-99A, DH-99AR

Digital Analog Addressable Duct Detector Unit

(DH-98AR and DH-99AR have relays built-in)

MS-RA, MS-RA/R, MS-KA/R Remote Test Station for DH-98AR & DH-99AR

DCP-FRCME-M Contact Monitoring Module (mini w/terminal blocks)

DCP-FRCME-P Contact Monitoring Module (mini w/pigtail leads)

DCP-FRCME-4 Contact Monitoring Module (with faceplate/indicating LED)

DCP-FRCMA, DCP-FRCMA-I Class A Contact Monitoring Module (FRCMA-I has built-in SCI)

DCP-DIMM Dual Input Monitor Module (with faceplate/indicating LED)

DCP-CZM Conventional Zone Module

DCP-R2M Dual Relay Module

DCP-R2ML/H Series Dual Relay Module (R2ML-I & R2MH-I has built-in SCI)

DCP-SOM Supervised Output Module

DCP-SOM-A, DCP-SOM-AI Class A Supervised Output Module (SOM-AI has built-in SCI)

DCP-SOM-R Supervised Output Module for Releasing Pre-action System

DCP-SCI Short Circuit Isolator Module

DCP-AMS Series Addressable Manual Pull Station

ACCESSORIES TCH-B100 Hand Held Programmer (portable device addresser)

FN-ACC Battery/Accessory Enclosure (houses up to 33AH size batteries)

FNP-ETR Enclosure Trim Ring for panel flush mount

Hochiki America Corporation FireNET DIGITAL ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL Specifications subject to change without notice.

FireNET Plus® - DIGITAL ANALOG ADDRESSABLE FIRE ALARM CONTROL PANEL

SPECIFICATIONS

Page 11: FireNET Series DIGITAL ANALOG ADDRESSABLE FIRE ALARM

FN-LCD-N - LCD NETWORK ANNUNCIATOR

STANDARD FEATURES

UL 864 9th Edition Listed

320 character liquid crystal display (8 line x 40 character)

LED indicators for Fire, Supervisory Alarm, Pre-Alarm, Fire Output Active, Power On, On Test, Panel Sounder Silenced, Delay Active, More Events, Point Bypassed, General Trouble, Power Trouble, System Trouble & NAC Trouble

Dual RS485 ports for primary fire network

RS485 slave bus for expansion - up to 32 FN-4127-IO boards or up to 15 FN-LCD-S serial annunciators and up to 17 FN-4127-IO boards

2 built-in RS-232 interfaces for programming via a PC and serial printer interface

4 on board programmable Form C relays rated at 1 Amp at 30VDC (Fire, Supervisory, Trouble & Auxiliary)

Same controls as the FireNET® fire panel (Reset, Panel

Sounder Silence, Lamp Test, Alarm Silence, Re-sound Alarm, Fire Drill, Programmable Function, More Events, More Fire Events, Enter & Exit)

Local piezo sounder for event notification

Supports user codes & firefighter key to enable access & controls

Powered by FireNET® Aux 24VDC or UL fire listed Aux.

24VDC supply

Available in red or gray, and can be surface or flush mounted (using trim ring)

True network annunciator, any or all panels can be routed to the FN-LCD-N. In addition, each event category can be individually routed to the FN-LCD-N

Up to (64) FireNET® panels & FN-LCD-N's can be net-

worked together in any combination

500mA of auxiliary power available rated at 24VDC

Auto-learn feature

Built-in help & alarm information screens

Fire drill function

Each FN-LCD-N is completely independent

The FN-LCD-N can be configured to remote reset, silence, resound, any or all panels on the network in any combina-tion

Hochiki America Corporation

7051 Village Drive, Suite 100, Buena Park, CA 90621-2268

Phone: 714/522-2246 Fax: 714/522-2268

Technical Support: 800-845-6692 or [email protected]

Find latest revision at www.hochiki.com

F0071 Rev2 04/2020

DESCRIPTION

The FN-LCD-N type LCD network annunciator is de-signed to be used with the FireNET

® analog addressa-

ble system. It allows for remote access, monitoring, and control of the FireNET

® system throughout the building.

The FN-LCD-N is a true network annunciator that can access, monitor, and control any or all FireNET

® panels

in the network. Each FN-LCD-N is completely inde-pendent. The highly intuitive user interface and 320 character LCD display of the FN-LCD-N is exactly the same as the FireNET

® panel. In addition to routing any

panel in the network to the FN-LCD-N, every event cat-egory within each panel can also be individually routed, as well as routing of all remote control functions (reset, alarm silence, re-sound alarm) from individual panels. The FN-LCD-N supports the same RS485 expansion port as the FireNET

® panel, allowing for FireNET

® ex-

pansion boards and accessories to be connected to the network annunciator.

The FN-LCD-N also has (4) output relays for fire, su-pervisory, trouble & auxiliary. The relays are program-mable (except supervisory).

Security is established by the use of a password or fire-fighters enable key. Designed to be aesthetically pleas-ing, the FN-LCD-N is available in red or gray and can be surface or flush mounted using a standard trim ring kit.

S5694

PRODUCT LISTINGS

California State

Fire Marshal

7120-0410:0165

Specifications subject to change without notice. Continued on back.

UL 864, NFPA 70

& 72:

Signaling Device

Page 12: FireNET Series DIGITAL ANALOG ADDRESSABLE FIRE ALARM

SPECIFICATIONS

ENGINEERING SPECIFICATION

The contractor shall furnish and install where indicated on the plans, the network annunciator model FN-LCD-N. The FN-LCD-N connects to the FireNET

® fire alarm control panel (FACP) network. The network annunciator is capable of

annunciating on its 320 character display and local buzzer, the condition of any FireNET® FACP or network annunci-

ator on the network. Up to 64 FN-LCD-N network annunciators or FireNET® FACP's may be connected together on

the network. The FN-LCD-N is UL Listed, and has surface or flush mount capability.

WIRING DIAGRAM

Input DC 24 VDC @ 270mA Max. ( + Aux. Power Load)

Aux. Output DC 24 VDC @ 500mA

Dimensions 14.5” W x 12.2” H x 3.4” D

Weight 9.4 lbs

Color Red (optional gray)

Material ABS/steel enclosure

Operating Temperature 32° F (0° C) 120° F (49° C)

Relative Humidity 85% RH Non-Condensing

Display 8 line x 40 character LCD (320 characters total)

Network Dual RS485 ports (64 nodes max.)

Relay Outputs (4) From C 1amp @ 30 VDC

PC Port RS232

Printer Port RS232

Expansion Port RS232

Hochiki America Corporation FN-LCD-N Specifications subject to change without notice.

FN-LCD-N - LCD NETWORK ANNUNCIATOR

Conventional Relay Contacts rated for 1A @ 30VDC. Must be connected to power-limited source (not supervised) (resistive)

To AUX 24VDC of control panel or UL Listed AUX 24VDC Power Supply

Network Connections See manual for details

24VDC Output (500mA max) typically used for low current devices. See manual for additional details

RS485 to IO Boards

Network LCD annunciator example