Upload
others
View
1
Download
0
Embed Size (px)
Citation preview
Gra
de 3
00 4
0 ba
r dia
Gra
de 5
00 7
0 ba
r dia
min
.lap
See
Not
eSe
e N
ote
See Note
Refer to NZS 4229 or specific design for dimension, reinforcing, and ground clearances
See Note
200 x 200 haunch
75mm minimum granular fill
Damp proof membrane
Interior plaster/finish asspecified
Horizontal reinforcement
Grout 17.5 MPa(except sea spray zones 25MPa)Vertical reinforcement central to cavity
100mm slab
Reinforcing meshConcrete (17.5 MPa)
Firth HotBloc®
Polystyrene
Exterior plaster/finish as specifiedwith applied waterproof coating
Finishedfloor level
Groundclearence
per E2/AS1D12
D12 ties @ 600ctrs.(lap 600 min.)
www.firth.co.nzDisclaimer : This information is intended solely as a guide for use of Firthproducts. Before using a Firth product you should ensure that the product issuitable for use in the specific application. Nothing in this informationconstitutes a statement of fitness for particular purpose - appropriate expertadvice should always be obtained. Firth makes no warranty regarding the useof this information with non-Firth product.
© 2009 . The copyright of this document isthe property of Firth and shall not bereproduced, copied, loaned or disposed ofdirectly, or indirectly, nor used for anypurpose other than that for which it isspecifically furnished without prior consent.For Technical Advice: Ph. 0800 800 576
Firth HotBlocEdge Thickened Slab Detail 103103_edge_thickened .dwg
February 2009Scale 1:10
®
Notes:
Refer to CCANZ CO.01:2011 for situations where a floor rebate is required.••
®
• If a rebate is required increase footing width to block width +150mm.