Flat plate sensor location. Installation options. For more information: Rod Hyatt, (508) 542-9830 [email protected] ASKROD.com. Placing the sensor on flat plate collectors. Optimal sensor attachment. Not advised! The sensor does not penetrate the collector. - PowerPoint PPT Presentation

Citation preview

Page 1: Flat plate sensor location

Flat plate sensor locationInstallation options

For more information:Rod Hyatt, (508) [email protected]

Page 2: Flat plate sensor location

Placing the sensor on flat plate collectors

Page 3: Flat plate sensor location

Optimal sensor attachment

Yes! Sensor is placed inside the collector, under the glass

Not advised!The sensor does not penetrate the collector.* Will not work on drainback systems.

Page 4: Flat plate sensor location

Sensor placement instructionsStep 1:With a 15/64” sharp drill bit, carefully drill alongside the hot-out connection and insert the solar control sensor for better protected temperature sensing.

Page 5: Flat plate sensor location

1. Drill sensor hole through grommet (illustrated on previous slide)

2. Sweat on plumbing connection3. Lubricate drilled hole4. Insert sensor for direct pipe contact

Above: The sensor tip inserted inside the panel, placed against the header

Left: The sensor, as seen through the glass of the collector

Above: The sensor is lubricated and slipped inside predrilled hole

Page 6: Flat plate sensor location

All done — neatly and efficiently