14
OPERATING INSTRUCTIONS MANUAL FLE-60CSA INDUSTRIAL / COMMERCIAL ELECTRIC HEATER (OPERATOR MUST RETAIN FOR FUTURE REFERENCE) Suitable for indoor or outdoor installation / Unvented / Unattended Type 26 Benfield Drive, St.Catharines, Ontario Canada L2S 3V5 (P) 905-685-4243 - (F) 905-685-0113

FLE-60CSA - DynaBlast...Use: The FLE-60CSA Electric Construction Heater is designed for temporary heat only. The heater may be installed indoors or out and used to bring 100% …

  • Upload
    others

  • View
    2

  • Download
    0

Embed Size (px)

Citation preview

  • OPERATING INSTRUCTIONS MANUAL

    FLE-60CSA

    INDUSTRIAL / COMMERCIAL ELECTRIC HEATER(OPERATOR MUST RETAIN FOR FUTURE REFERENCE)

    Suitable for indoor or outdoor installation / Unvented / Unattended Type

    26 Benfield Drive, St.Catharines, Ontario Canada L2S 3V5

    (P) 905-685-4243 - (F) 905-685-0113

  • FLE-60CSA OPERATING INSTRUCTIONS MANUAL

    GENERAL HAZARD WARNING:

    FAILURE TO COMPLY WITH THE PRECAUTIONS

    AND INSTRUCTIONS PROVIDED WITH THIS

    HEATER, CAN RESULT IN DEATH, SERIOUS

    BODILY INJURY AND PROPERTY LOSS OR

    DAMAGE FROM HAZARDS OF FIRE, EXPLOSION

    BURN ASPHYXIATION, OR ELECTRICAL SHOCK

    ONLY PERSONS WHO CAN UNDERSTAND AND

    FOLLOW THE INSTRUCTIONS SHOULD USE OR

    SERVICE THIS HEATER.

    IF YOU NEED ASSISTANCE OR HEATER

    INFORMATION SUCH AS AN INSTRUCTIONS

    MANUAL, LABEL, ETC. CONTACT THE

    MANUFACTURER

    WARNING: FIRE, BURN, INHALATION

    AND EXPLOSION HAZARD, KEEP SOLID

    COMBUSTIBLES, SUCH AS BUILDING

    MATERIALS, PAPER, OR CARDBOARD, A SAFE

    DISTANCE AWAY FROM THE HEATER AS

    RECOMMENDED BY THE INSTRUCTIONS

    NEVER USE THE HEATER IN SPACES WHICH DO

    OR MAY CONTAIN VOLATILE OR AIRBORNE

    COMBUSTIBLES, OR PRODUCTS SUCH AS

    GASOLINE SOLVENTS, PAINT THINNER, DUST

    PARTICLES OR UNKNOWN CHEMICALS

    WARNING: NOT FOR HOME OR

    RECREATIONAL VEHICLE USE

  • Introduction

    You have just received an FLE-60CSA 60kW Electric Construction Heater manufactured by Flagro Industries.

    Use: The FLE-60CSA Electric Construction Heater is designed for temporary heat only.

    The heater may be installed indoors or out and used to bring 100% outdoor air, or heat

    and re-circulate building air. The FLE-60CSA is designed to heat large spaces, buildings

    and machines without worrying about on site fuel.Quality: The FLE-60CSA is built with the highest quality of components giving our

    customers the confidence they deserve in a Flagro product. Convenience: The FLE-60CSA gives our customers the flexibilty of a 20kW/40kW/60kW heat setting.

    The heater is equipped with a fan speed inverter control that provides optimum temperature rise

    by adjusting blower output at each heat setting. Colour coded Cam Locks power connections

    for easy installation. Remote thermostat option available.

    Inlet Duct Adapter

    The FLE-60CSA includes a permanant inlet duct adapter.

    Heater manufacturer approved ducting must be attached for outdoor use.

    Safety

    Always verify that you have proper voltage supply. (575V) It is important to check

    the wiring connections inside the heater before plugging in the Cam Locks.

    Use a meter to measure volt supply to each cam lock.

    Work on the internal systems should only be attempted by a certified electrician and

    only when power has been disconnected and can not be reconnected to the heater.

    Grounding

    The heater is supplier with a cam lock system with a grounding connection and is indicated with a "G"

    on the cam lock panel. The heater is also supplied with a grounding nuts found on all panels.

    It is very important to double check that all grounding connections are properly secure.

    Clearance from Combustibles

    The discharge temperature of these units may reach very high temperatures. Maintain minimum

    distance from combustible materials as follows:

    Top: 6 Inches

    Bottom: 6 Inches

    Sides: 6 Inches

    Discharge: 15 FT

  • MAINTENANCE

    1 Every heater should be inspected before each use, and at least annually by a

    qualified service person

    2 The appliance must be kept clear and free from combustible materials,

    gasoline and other flammable vapors and liquids

    3 The flow of ventilation air must not be obstructed.

    Be sure to check the fan assembly and ensure the motor and blade

    are operating properly and it is important to clean air filters

    4 Compressed air may be used to keep components free of dust and dirt

    build up.

    Pre-Start Checklist

    1 Heater must be level and lockable wheels must be in the lock position

    2 Make sure blower switch and both heat switches are in the "OFF" positions

    3 Make sure the air intakes are free from any obstruction(s)

    4 Make sure the heater oulet is free from any obstruction(s)

    5 Make sure the heater is properly grounded

    6 Check power supply voltage and ampacity

    7 If using the heater outdoors, heater manufacturer approved ducting must be attached to heater.

  • START UP INSTRUCTIONS

    1 Determine power source - 575V (confirm power source is correct)

    2 Remove top cover and inspect all wiring

    (once complete, secure top cover to heater using the same hardware)

    3 Connect Flanged Camlocks to female camlocks ( colour coded)

    Connect camlocks as follows:

    Red A

    Black B

    Blue C

    Ground G

    3 PHASE UNIT CONNECTION

    4 Turn on power supply

    5 Pull "Master" button to the out position

    6 Determine "Manual" or Remote Thermostat (if remote, set desired temperature)

    7 Turn Blower on/off switch to the "ON" position

    (The blower will start and the green air flow light will come on)

    8 Turn on heater settings as desired

    ( 60kW= 20kW & 40kW combined)

    Failure to have proper air flow will cause unit to overheat and shut down

    The green light should come on and air should be pushed through the outlet port

    Check to see that only the green light is on.

    Caution: Heater body panels will get very hot

  • Notes:

    Speed inverter is pre-set for optimum air flow/temperature rise.

    Based on kW selection, blower will adjust speed. See Chart below

    HEAT SETTING BTUH CFM TEMP. RISE NOISE RATING

    60 kW 205,000 3300 110DEG F/43DEG C 67 DB

    40 kW 164,000 2800 85DEG F/30DEG C 63 DB

    20kW 82,000 2450 50DEG F/10DEG C 63DB

    FAN ONLY 3900 71DB

    SHUTDOWN

    1 Move all heater setting controls to the "OFF" position

    2 Leave Fan in the "ON" position for 3-5 minutes

    3 Turn Fan OFF

    ( blower is preset to run for 30 seconds before coming to a complete stop)

    4 Push Master button "IN"

    5 Shut off all power source

    6 Disconnect all power sources

    7 Store heater

  • 26 Benfield Dr. St.Catharines, Ontario Canada L2S 3V5

    (O) 905-685-4243 (F) 905-685-0113

    HEATER SPECIFICATIONS

    MODEL FLE-60CSA

    Power Requirements 575V

    MAXIMUM INPUT (KW) 205,000 btu

    BLOWER 1 1/2 H.P.

    TEMPERATURE RISE (above ambient) 20KW 50 DEG F

    40KW 85 DEG F

    60 KW 110 DEG F

    AMP DRAW MOTOR 1.3 AMPS

    20KW 23 AMPS

    40KW 34 AMPS

    60KW 57 AMPS

    DB (noise level) FAN ONLY 71DB

    20KW 63DB

    40KW 63DB

    60KW 67 DB

    INLET SIZE 16" X 16"

    OUTLET SIZE 18" x 13"

    (Designed for 20" Dia. Ducting)

    DIMENSIONS 32 X 48 X 25 1/2

    H X L X W (IN.)

    WEIGHT 290 LBS. (unboxed)

    AIR CIRCULATION 3900 CFM

  • PARTS LIST FOR FLE-60CSA

    Part Number Part Description

    FLE-601A 60KW RESISTOR ELEMENT (575 VOLT)

    FLE-602 FAN BLADE ASSEMBLY

    FLE-603A 1-1/2 HP MOTOR (575 VOLT)

    FLE-604A VARIABLE SPEED DRIVE FOR FLE-60 (575 VOLT)

    FLE-605A WIRED CONTROL/OPERATOR PANELS (575 VOLT)

    FLE-606 ADJUSTABLE MOTOR BASE

    FLE-607 7" FAN PULLEY

    FLE-608 3.25" MOTOR PULLEY

    FLE-609 6" LOCKABLE SWIVEL CASTER (TWO REQUIRED)

    FLE-610 6" RIGID CASTER (TWO REQUIRED)

    FLE-611 BLUE MALE PANEL CAM-LOCK

    FLE-611A BLUE SNAP COVER

    FLE-612 BLACK MALE PANEL CAM-LOCK

    FLE-612A BLACK SNAP COVER

    FLE-613 GREEN MALE PANEL CAM-LOCK

    FLE-613A GREEN SNAP COVER

    FLE-614 RED MALE PANEL CAM-LOCK

    FLE-614A RED SNAP COVER

    FLE-615 BLUE FEMALE DETACHABLE CAM-LOCK

    FLE-616 BLACK FEMALE DETACHABLE CAM-LOCK

    FLE-617 GREEN FEMALE DETACHABLE CAM-LOCK

    FLE-618 RED FEMALE DETACHABLE CAM-LOCK

    FLE-619 LIFTING LATCH (FOUR REQUIRED)

    FLE-620 FAN BELT

    FLE-621 GROUNDING BLOCK

    FLE-622 DISTRIBUTION BLOCK

    FLE-623 OUTLET HIGH LIMIT - 200 F

  • FLE-624 CONTACTOR - 65A 3P

    FLE-625 CONTACTOR - 32A 3P

    FLE-626 DAYTON CUBE RELAY (TWO REQUIRED)

    FLE-627A 575 VOLT TRANSFORMER

    FLE-628 60 AMP CLASS T FUSE (THREE REQUIRED)

    FLE-629 30 AMP CLASS T FUSE (THREE REQUIRED)

    FLE-630 5 AMP CLASS CC TIME DELAY (THREE REQUIRED)

    FLE-631 1/2 AMP CLASS CC TIME DELAY (TWO REQUIRED)

    FLE-632 5 AMP AGC GLASS FUSE

    FLE-633 TWO POSITION SWITCH (FOUR PER HEATER)

    FLE-634 EMERGENCY STOP BUTTON

    FLE-635 RED HIGH LIMIT/NON-PROVEN AIR LIGHT (TWO PER HEATER)

    FLE-636 GREEN AIR PROVEN LIGHT

    FLE-637 BULBS FOR FLE-635 & FLE-636 (THREE PER HEATER)

    FLE-638 OPERATOR BLOCK FOR FLE-635 & FLE-636

    FLE-639A N/C CONTACT BLOCK (THREE PER HEATER)

    FLE-640A N/O CONTACT BLOCK (SEVEN PER HEATER)

    FLE-641 SAIL SWITCH (COMPLETE)

    FLE-642 INTERNAL FILTER (TWO PACK)

    FV-414B THERMOSTAT CONNECTION

  • FLE-60– PARTS LIST

    FLE-601A (575 VOLT)

    60KW RESISTOR ELEMENT

    PULLEYS

    FLE-602

    FAN BELT

    FAN BLADE ASSEMBLY

    VARIABLE SPEED DRIVE

    1.5 HP MOTOR

    FLE-603A (575VOLT)

    FLE-604A (575 VOLT)

    FUSES

    FLE-620FLE-608 – 3.25” PULLEY

    FLE-607 – 7” PULLEY

    FLE-628 - 60 amp class T

    FLE-629 – 30amp class T

    FLE-630 - 5amp class CC

    FLE-631 - 1/2amp class CC

    FLE-632 - 5amp AGC - glass

    TRANSFORMER

    FLE-627 – 480V

    FLE-627A – 575V

    GROUNDING BLOCK

    FLE-621

  • FLE-60 PARTS LIST

    2 POSITION SWITCH

    HIGH LIMIT

    FLE-63320KW

    40KW

    THERMOSTAT/MANUAL

    BLOWER ON/OFF

    FLE-623 ( 200F)

    SAIL SWITCH

    RELAY

    FLE-626(2 PER UNIT)

    CONTACTORS

    FLE-625 – 32A 3P

    FLE-624 – 65A 3P

    EMERGENCY STOP BUTTON

    FLE-634

    GREEN AIR PROVEN LIGHT

    FLE-636

    HIGH LIMIT/AIR PROVEN LIGHT THERMOSTAT

    FLE-635 FV-414B

    FLE-641

  • FLE-60 PARTS LIST

    WHEELS

    FLE-609 – 6” LOCKABLE

    FLE-610 – 6” RIGID

    CAM-LOCK DETACHABLE

    FLE-615 – BLUE

    FLE-616 – BLACK

    FLE-617 – GREEN

    FLE-618 - RED

    FLE-611 – BLUE

    FLE-612 – BLACK

    FLE-613 – GREEN

    FLE-614 - RED

    CAM-LOCK - PANEL

    N/C CONTACT BLOCK N/O CONTACT BLOCK

    FLE-639A(3 PER UNIT)

    FLE-640A(7 PER UNIT)

    SNAP COVERS - PANEL

    FLE-611A – BLUE

    FLE-612A – BLACK

    FLE-613A – GREEN

    FLE-614A - RED

  • P/N DESCRIPTION

    FEH-60FR OUTER FRAME

    FEH-616 TOP PANEL

    FEH-611C LEFT SIDE PANEL

    FEH-610C RIGHT SIDE PANEL

    FEH-612C FRONT PANEL

    FEH-614 REAR SIDE PANEL

    FLE-170 CONTROL PANEL RAIN GUARD

    BODY PANELS

  • 0100

    0101

    0102

    0103

    0104

    0105

    0106

    0107

    0108

    0109

    0110

    0111

    0112

    0113

    0114

    0115

    0116

    0117

    0118

    0119

    0120

    0121

    0122

    0123

    0124

    0125

    0126

    0127

    0128

    0129

    0130

    0131

    0132

    0133

    0134

    0135

    0136

    0137

    0138

    0139

    0140

    0141

    0142

    0143

    0144

    0145

    0146

    0147

    0148

    0149

    0150

    0151

    0152

    0153

    0154

    0155

    0156

    0157

    0158

    0159

    Description

    253XXXDate

    FLE-605A HEATER CONTROL PANEL

    Modification Name

    Job Number

    4395 KENT AVENUENIAGARA FALLSONTARIO L2H 1J1CANADAt: +1.905.295.2525f: +1.905.295.2528http://www.PowerUnderControl.com

    2016/09/06

    DG 2016/01/19

    DM 2016/01/19Rev.

    Date

    Date

    Date

    Creator

    Checked

    Approved Page 01 OfMPNL 09Designation

    THIS DRAWING & DESIGN ARE PROPRIETARY TO SYNCHROENGINEERING LIMITED ALL RIGHTS RESERVED. NEITHER THE

    DRAWING OR DESIGN MAY BE COPIED OR OTHERWISEDISSEMINATED IN ANY MANNER OR FORM, IN WHOLE OR IN PART,WITHOUT, IN EACH INSTANCE, THE PRIOR WRITTEN CONSENT OF

    SYNCHRO ENGINEERING LIMITED. THESE DRAWINGS AREPROTECTED BY CANADIAN AND UNITED STATES COPYRIGHT LAW.

    UNAUTHORIZED REPRODUCTION OF THESE DRAWINGS ISPROHIBITED. (C) SYNCHRO ENGINEERING LIMITED 2016.

    KE

    60 KW575 VAC3 PHASE

    60 HZ

    A24

    B24

    C24

    A48

    B48

    C48

    1 2

    (0145)

    C1

    3 4

    5 6

    1 2

    (0147)

    C2

    3 4

    5 6

    C60

    B60

    A60

    NOTE: #16 AWG CONTROL WIRING TO BE TEW BC

    2

    VFD(0154)

    L1

    L2

    L3

    T1

    PEPE

    T2

    T3

    H1

    T1

    100VA 575V/120V

    H4

    X4

    X1

    GN/YE14 AWG

    1

    J1 P1

    1

    PB1

    MASTER PULLON

    (0153)

    P1

    2

    J1

    2

    RD16 AWG

    1

    40''

    RD16 AWG

    2

    40'' TB3RD

    16 AWG

    2

    34''

    TB3

    TB3

    RD16 AWG

    2

    16''PS1

    AIR FLOW

    11 12R1

    (0131)

    11 12R2

    (0139)

    5A

    FU1TB2

    X1

    34"RD

    16 AWG1

    TB5 A1 A2

    R1

    (0135)(0141)

    TBX2

    TBX2

    G

    PL1AIRFLOW PROVEN

    TB5

    R

    PL2

    AIRFLOW NOTPROVEN

    R

    PL3OVERTEMP

    RD16 AWG

    3

    40''

    RD16 AWG

    4

    40''

    2BK

    14 AWG

    22''SEW-2

    3BK

    14 AWG

    22''SEW-2

    TB6

    TB7

    TB3 TS1

    OVERTEMP TB8 A1 A2

    R2

    (0137)(0141)

    TBX2

    21 24R1

    (0131)

    21 24R2

    (0139)

    TB10 OFF ON

    SS2

    BLOWER

    MANUAL REMOTE

    SS1

    OFF ON

    SS3

    20KW

    A1 A2C1

    (0100)(0101)(0102)

    TS2

    REMOTEOVERTEMP

    OFF ON

    SS4

    40KW

    TB13

    TB14 A1 A2

    C2

    (0107)(0108)(0109)

    TBX2

    VFD(0113)

    VFD CONTROL CIRCUIT CONNECTIONS

    1 4 13B 13A

    RD16 AWG

    3

    16''

    3

    RD16 AWG

    3

    34''

    WH16 AWG

    X2

    34''

    X2

    WH16 AWG

    X2

    RD16 AWG

    4

    34''

    RD16 AWG

    5

    40''

    RD16 AWG

    5

    34''

    4

    5

    BK14 AWG

    18''SEW-2

    BK14 AWG

    18''SEW-2

    6 X2

    7 8ARD

    16 AWG

    8A

    34''

    RD16 AWG

    8A

    40''

    8

    9

    9A

    RD16 AWG

    10

    34''

    RD16 AWG

    10

    40''

    RD16 AWG

    11

    40''

    RD16 AWG

    11

    34''

    X2

    X2

    YE13A

    YE13A

    YE13B

    YE13B

    YE13

    YE13

    YE12

    YE12A

    +LOT1 (Operator Panel)

    +LOT1 (Operator Panel)

    1

    J4 P4

    1

    3

    J1 P1

    3

    P1

    44

    J1

    P1

    55

    J1

    J4

    2

    P4

    2

    P1

    9

    J1

    9

    6

    J1 P1

    6

    P1

    7

    J1

    7

    J1

    8

    P1

    8

    J3

    3

    P3

    3

    P3

    4

    J3

    4

    J3

    2

    P3

    21

    J3 P3

    1

    J2

    2

    P2

    21

    J2 P2

    1

    L1BK10 AWG

    64''SEW-2

    L2

    L3

    1L1BK12 AWGSEW-2

    1L2

    1L3

    1R1BK12 AWG

    36''SEW-2

    1R2

    1R3

    L1BK6 AWG

    64''SEW-2

    L2

    L3

    2L1BK8 AWGSEW-2

    2L2

    2L3

    2R1BK8 AWG

    36''SEW-2

    2R2

    2R3

    L1BK10 AWG

    64''SEW-2

    L2

    L3

    3L1BK14 AWGSEW-2

    3L2

    3L3

    L1BK10 AWGSEW-2

    L2BK10 AWGSEW-2

    2

    2

    10

    11

    FB1

    30 A

    FB2

    60 A

    FB3

    5 A

    FB40.5 A

    P5

    2

    J5

    2

    P5

    11

    J5

    99

    YE12

    YE12

    2

    U1

    V1

    W1

    PE

    1.5 HPFLA = 1.9 A3

    M

    T1

    T2

    T3

    PE

    GBGround Bar

    H4

    H1

    1

    GBGround Bar

    PE

    RD16 AWG

    X2

    40''

    0120(.0120)

    0122(.0124)

    0120 / (.0130)

    0122 / (.0130)

    L1

    L2

    L3

    GND