2
1 of 2 Revised March 2011 July 31 st , 2007 All Florens Container Services dry van and open top containers off-hired or surveyed for on hire, on or after August 1 st , 2007, will be inspected to an amended IICL 5 inspection criteria. Experience has shown that repairs can accelerate the degradation of the containers through the promotion of corrosion and the weakening of structural components. As a consequence, it’s prudent to make repairs only to the extent necessary to meet all regulatory requirements and maintain the container in a safe and fully operational condition. With this in mind, Florens has reviewed the IICL-5 inspection criteria with the objective of eliminating unnecessary repairs. The Florens amendments to IICL-5 are the result of that review. Summary of Florens Amendments to IICL-5 1. A single dent criterion of 30mm applies to both flat-bar and box-section top side rails. 2. A single dent criterion of 40 mm applies to both front and rear headers. 3. A 20mm dent criterion applies to corner posts independent of the number of dents (i.e., the IICL- 5, two 15mm dent criterion is eliminated). 4. The IICL-5 end frame criterion of ISO + 5mm has been amended to: 4.1 For the end faces, the criterion remains ISO + 5mm. 4.1 For the side faces, the criterion has been amended to ISO + 10 mm. 5. The 35mm side panel dent criterion is eliminated. It is replaced with a 35mm internal cube intrusion criterion and an ISO + 20mm outward criterion. 5.1 The 35mm cube intrusion criterion is measured in the standard IICL way: from the outside faces of the recessed corrugations. 5.2 The ISO + 20mm side panel criterion measurement method is standardized as 30mm measured on the inside recessed corrugation. 6. The 35mm front and door panel dent criterion is eliminated. It is replaced with a 35mm internal cube intrusion criterion. The standard IICL-5 ISO + 5mm outward criterion still applies. 7. The 35mm roof panel dent criterion is eliminated. It is replaced with a 50mm internal cube intrusion criterion and a corner casting + 15mm outward criterion. 7.1 The 50mm cube intrusion criterion is measured in the standard IICL way: below the top surfaces of the top side rails on the interior of the container. 7.2 The outward limit for the roof is defined by a plane 15mm above the plane of the top surfaces of the top corner castings.

Florens Amendement to IICL Customer 5 Rev2

Embed Size (px)

Citation preview

Page 1: Florens Amendement to IICL Customer 5 Rev2

1 of 2 Revised March 2011

July 31st, 2007

All Florens Container Services dry van and open top containers off-hired or surveyed for on hire, on or after

August 1st, 2007, will be inspected to an amended IICL – 5 inspection criteria.

Experience has shown that repairs can accelerate the degradation of the containers through the promotion of

corrosion and the weakening of structural components. As a consequence, it’s prudent to make repairs only to

the extent necessary to meet all regulatory requirements and maintain the container in a safe and fully

operational condition.

With this in mind, Florens has reviewed the IICL-5 inspection criteria with the objective of eliminating

unnecessary repairs. The Florens amendments to IICL-5 are the result of that review.

Summary of Florens Amendments to IICL-5

1. A single dent criterion of 30mm applies to both flat-bar and box-section top side rails.

2. A single dent criterion of 40 mm applies to both front and rear headers.

3. A 20mm dent criterion applies to corner posts independent of the number of dents (i.e., the IICL-

5, two 15mm dent criterion is eliminated).

4. The IICL-5 end frame criterion of ISO + 5mm has been amended to:

4.1 For the end faces, the criterion remains ISO + 5mm.

4.1 For the side faces, the criterion has been amended to ISO + 10 mm.

5. The 35mm side panel dent criterion is eliminated. It is replaced with a 35mm internal cube

intrusion criterion and an ISO + 20mm outward criterion.

5.1 The 35mm cube intrusion criterion is measured in the standard IICL way: from the outside

faces of the recessed corrugations.

5.2 The ISO + 20mm side panel criterion measurement method is standardized as 30mm measured

on the inside recessed corrugation.

6. The 35mm front and door panel dent criterion is eliminated. It is replaced with a 35mm internal cube

intrusion criterion. The standard IICL-5 ISO + 5mm outward criterion still applies.

7. The 35mm roof panel dent criterion is eliminated. It is replaced with a 50mm internal cube

intrusion criterion and a corner casting + 15mm outward criterion.

7.1 The 50mm cube intrusion criterion is measured in the standard IICL way: below the top

surfaces of the top side rails on the interior of the container.

7.2 The outward limit for the roof is defined by a plane 15mm above the plane of the top surfaces of

the top corner castings.

Page 2: Florens Amendement to IICL Customer 5 Rev2

2 of 2 Revised March 2011

8. The amended criterion for downward bow limit for the gooseneck tunnel, fork lift pockets, outriggers

and cross members is 15 mm from the original position or below the bottom faces of the corner

castings.

9. The allowable height difference between floor panels has been increased from 5mm to 10mm.

10. The IICL-5 miscellaneous inspection criteria of ISO + 10mm for all components other than the end

frame components has been eliminated and replaced with specific limits as listed in the table below.

Note: Unless specifically amended, the standard IICL-5 inspection criteria apply.

Components IICL-5 + ISO damage limits - Amendments

Side panels

* OUTWARDS: Maximum 20 mm (13/16 in) beyond plane of side surfaces of corner

fittings

* For side panels, measured on interior recessed corrugations as a 30 mm (1-3/8

in) outward deformation

Corner posts

INWARDS: Follow criteria in Table 5.2 (20 mm [13/16 in] maximum, or 15 mm [9/16 in]

maximum for two or more dents)

OUTWARDS: Maximum 5 mm (3/16 in) beyond plane of end surfaces or 10 mm

(3/8 in) beyond plane of side surfaces of corner fittings

Roof panels

DOWNWARDS: Follow criteria in Table 5.5 (50 mm [2 in] maximum internal

dimension reduction)

UPWARDS: Maximum 15 mm (5/8 in) above plane of upper surfaces of top corner

fittings

Crossmembers,

outriggers, fork-lift

pocket sides and

gooseneck tunnel rails

DOWNWARDS: Lower flange cannot be lower than 15mm (9/16 in) from its

original position or below the plane of the lower surfaces of the bottom corner

fittings

INWARDS (fork-lift pocket sides): See “Fork-lift pocket opening WIDTH” below

Only the amended tolerance limits are shown; all other tolerance limits remain unchanged from Appendix C of

IICL-5.

Rev 03/2011

Rev 03/2011