Flow Diverters

Page 2: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

PRODUCTS SELECTION GUIDE

Product Selection Guide | Flow Diverters 3/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

PageP

psi (bar)Q

gpm (l/min)PortsModelDescriptionCircuit

3 ways fl ow diverters

VS 70

VS 75

VS 81

VS 82

VS 84

VS 85

VS 91

VS 92

VS 95

1/4”Gas

SAE4

3/8”Gas

1/2”Gas

SAE6

SAE8

1/2”Gas

3/4”Gas

SAE12

6,6 (25)

6,6 (25)

13,2 (50)

15,9 (60)

13,2 (50)

15,9 (60)

31,7 (120)

37,0 (140)

37,0 (140)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

7

7

9

9

9

9

11

11

11

VS 120

VS 125

VS 129

VS 151

VS 152

VS 155

VS 161

VS 165

VS 311

VS 312

VS 315

6 ways fl ow diverters

1/4”Gas

SAE4

1/4”G JIS B

3/8”Gas

1/2”Gas

SAE8

3/8”Gas

SAE8

1/2”Gas

3/4”Gas

SAE12

6,6 (25)

6,6 (25)

6,6 (25)

13,2 (50)

15,9 (60)

15,9 (60)

13,2 (50)

15,9 (60)

31,7 (120)

37,0 (140)

37,0 (140)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

13

13

13

15

15

15

17

17

19

19

19

6 ways bankable fl ow diverters

VS 120F

VS 125F

VS 241F

VS 245F

VS 246F

VS 281F

VS 285F

VS 286F

1/4”Gas

SAE4

3/8”Gas

SAE8

M18x1,5

1/2”Gas

SAE10

M18x1,5

5,3 (20)

5,3 (20)

13,2 (50)

13,2 (50)

13,2 (50)

23,8 (90)

23,8 (90)

23,8 (90)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

4500 (310)

21

21

24

24

24

27

27

27

6 ways piloted fl ow diverters

VS 400 1”Gas 58,1 (220) 4500 (310) 30

Page 3: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

PRODUCTS SELECTION GUIDE

4/40 Flow Diverters | Product Selection Guide

Bosch Rexroth Corp., RA 90811, edition: 2006-01

Handles LV 32

Coils

Coils

Coils

Explosion Proof Solenoid

Connectors

Typical application

C36

C48

C65

GMA6039

GMA6040

GMA6041

26

36

44

13

13

13

PagePowerWatt

ModelDescription D.I.Inc.(mm)

D.E.Inc.(mm)

33

34

35

37

38

1,4x1,8(36x46)

d.0,6(d.14)

1,8x1,8(45x45)

d.0,7(d.19)

2,5x2,7(64x69,5)

D. 1.77(D. 45)

D. 1.77(D. 45)

d. 1,01(d. 25,7)

d. 0,8(d. 20,5)

d. 0,8(d. 20,5)

D. 1.77(D. 45)

d. 0,8(d. 20,5) 36

39

40

Page 4: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

PRODUCTS SELECTION GUIDE

Product Selection Guide | Flow Diverters 5/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

TECHNICAL DATA

FUNCTIONAL TESTINGAll performance curves in this catalogue are obtained using mineral based hydraulic oil with 32 cSt viscosity at 104°F (ISO VG 32 viscosity class).All valves go through functional testing at these conditions before shipment.Our test stands ensure 15 micron Absolute Filtration (NAS 9).

TEMPERATURE RANGESAmbient Temperature from –4°F to +122°F (-20°C a 50°C)Oil Temperature from –4°F to +176°F (-20°C a 80°C)

PORTSG sizes (BSPP) from G 1/4” to G 1” are standard; other threads can be manufactured upon request.

SEALSO-RINGS: Acryl – Nitrile Butadiene Rubber NBR (BUNA-N) standard for temperature between –4°F and +212°F (-20°C a 100°C). Fluorocarbo FPM (Viton) and other compounds are available on request.BACKUP RINGS: Lubrifl on – PTFE – PBK.

STOCKING OF NEW VALVESencapsulated by a protective wrapping, the valves shall not be exposed to direct sun light nor to source of heat or ozone (like electric motors running) and kept in a dry place at a temperature between –4°F and +122°F (-20°C a 50°C).

VALVES INSTALLATIONIt is recommended to follow these steps:· inspect the sub-plate to ensure that it is in good conditions and no external contaminant is present.· Check that O-Rings are intact and correctly positioned.· Don’t tighten screws or connectors more than the maximum torque specifi ed in the catalogue.

INLET VOLTAGETo obtain correct operation and long life of coils it is necessary that the operating voltage fl uctuations do not exceed +5% -10% of nominal voltage.

WORKING DUTYThe working duty ED of a coil is the ratio between energized time ti and full cycle time tc where tc=ti+tr and tr = de-energized time.ED = (ti/tc) · 100 %All coils are rated for ED = 100 % provided that temperature limit of their insulation class is not exceeded.

PROTECTION EN 60529On request coils with IP65/IP69K protection.

HYDRAULIC FLUIDIt must have physical lubricating and chemical properties suitable for use in hydraulic systems such as, for example: MINERAL OIL FLUIDS HL (DIN 51524 part1)MINERAL OIL FLUIDS HLP (DIN 51524 part2)For use of environmentally acceptable fl uids (vegetable or polyglycol base) please consult us.Viscosity class: with ISO-DIN, the viscosity class is expressed by ISO-VG (no.); the no. Indicates the average kinematic viscosity at 104°F (40°C) in mm2/s or centiStoks (cSt). - See Tab. A -

CONTAMINATION – FILTRATIONGENERAL INFORMATION: Manufacturers and users of hydraulic equipment admit that contamination is the most likely cause of malfunction or failure in hydraulic systems and reduces security and reliability of components and systems. Metal particles fl owing throughout the circuit scratch moving surfaces so that contamination level, if not controlled, increases very rapidly.It is strongly recomended to mantain contamination level at least at nominal values shown below, choosing adequate fi ltration products.

FILTRATION RATIO BETAx: It’s the ratio between the number of particles before and after the fi lter with diameter larger than X micron.

ABSOLUTE FILTRATION RATIO ISO 4572: It’s the diameter X of the largest particle with BETAx≥ 75.

CONTAMINATION CLASS ISO 4406: it’s expressed by 3 scale numbers representing respectively: the number of particles equal to or larger than 4 micron (c); the number of particles equal to or larger than 6 micron (c); the number of particles equal to or larger than 14 micron(c), contained in 0,0003g of fl uid.

CONTAMINATION CLASS NAS 1638: It’s expressed by one scale numbers representing the number of particles of different size ranges contained in 0,03g of fl uid. - See Tab. B -

Page 5: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

PRODUCTS SELECTION GUIDE

6/40 Flow Diverters | Product Selection Guide

Bosch Rexroth Corp., RA 90811, edition: 2006-01

VISCOSITY CLASS AND FILTRATION DATA

- Tabella B -

TYPE OF SYSTEMTYPE OF VALVE

FILTRATION RECCOMENDATIONS

NOMINAL FILTRA-TION

(micron)

ABSOLUTE FILTRA-TION RATING ISO

4572(BETAX ≥ 75)

CONTAMINATION CLASS ACCORDING TO:

ISO 4406 NAS 1638

System/components operating at HIGH PRESSURE >3626 psi (250bar)HIGH DUTY CYCLE APPLICATIONS

Systems/components with LOW dirt tolerance

System/components operating at MEDIUM HIGH PRESSURE

HIGH DUTY CYCLE APPLICATIONS Systems/components with moderately dirt

tolerance

System/components operating at LOW PRESSURE <1450 psi (100bar)LOW DUTY CYCLE APPLICATIONS

Systems/components with GOOD dirt tolerance

10 X = 10...12 19 / 17 / 14 8

15 X = 12... 15 20 / 18 / 15 9

25 X = 15... 25 21 / 19 / 16 10

- Tabella A -

Viscosity classKinematic viscosity

MAXIMUM AT 32°F MEDIUM AT 104°F MINIMUM AT 212°C (0°C) (40°C) (100°C)

ISO VG 10 90 10 2.4

ISO VG 22 300 22 4.1

ISO VG 32 420 32 5.0

ISO VG 46 780 46 6.1

ISO VG 68 1400 68 7.8

ISO VG 100 2560 100 9.9

Page 6: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

PRODUCTS SELECTION GUIDE

Product Selection Guide | Flow Diverters 7/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

PORT DETAILS

G 1/4 0,51 0,75 0,04 (13) (19) (1)

G 3/8 0,51 0,98 0,04 (13) (25) (1)

G 1/2 0,59 1,14 0,06 (15) (29) (1,5)

G 3/4 0,67 1,42 0,06 (17) (36) (1,5)

G 1” 0,75 1,77 0,08 (19) (45) (2)

- - - -

Thtreads

UNI-ISO 228d

G - BInc.

(mm)

Ø - L*Inc.

(mm)

NmaxInc.

(mm)

DIN 3852/2

* Different from DIN 3582/2 standard

SAE 4 0,47 0,75 0,49 0,094 12° 0,04 (12) (19) (12,5) (2,4) (1)

SAE 6 0,51 1,02 0,61 0,098 12° 0,04 (13) (26) (15,6) (2,5) (1)

SAE 8 0,59 1,18 0,81 0,102 15° 0,06 (15) (30) (20,6) (2,6) (1,5)

SAE 10 0,67 1,34 0,94 0,102 15° 0,06 (17) (34) (23,9) (2,6) (1,5)

SAE 12 0,79 1,61 1,15 0,13 15° 0,06 (20) (41) (29,2) (3,3) (1,5)

SAE 16 0,79 1,97 1,40 0,13 15° 0,08 (20) (50) (35,5) (3,3) (2)

- - - - - - - -

ThtreadsASA-B1-1

d

G - BInc.

(mm)

Ø - LInc.

(mm)

Ø - DInc.

(mm)

EInc.

(mm)K

7/16-20UNF-2B

9/16-18UNF-2B

3/4-16UNF-2B

7/8-14UNF-2B

1 1/16-12UN-2B

1 5/16-12UN-2B

NInc.

(mm)

ISO 11926-1 / SAE J514

M18x1,5 0,61 1,14 0,78 0,094 15° 0,06 (15,5) (29) (19,8) (2,4) (1,5)

ThtreadsISO 261

d

G - BInc.

(mm)

Ø - LInc.

(mm)

Ø - DInc.

(mm)

EInc.

(mm)K

NInc.

(mm)

UNI-ISO 6149-1

G 1/4 0,51 0,94 0,61 0,098 15° 0,04 (13) (24) (15,6) (2,5) (1)

ThtreadsUNI-ISO 228

d

G - BInc.

(mm)

Ø - LInc.

(mm)

Ø - DInc.

(mm)

EInc.

(mm)K

NInc.

(mm)

JIS B 2351

Page 7: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

PRODUCTS SELECTION GUIDE

8/40 Flow Diverters | Product Selection Guide

Bosch Rexroth Corp., RA 90811, edition: 2006-01

VS 70/75 VS 81/82/84/85 VS 91/92/95

VS 120/125/129 VS 151/152/155 VS 161/165

VS 311/312/315 VS 120F/125F VS 241F/245F

VS 281F/285F VS VM + LV VS 400

Page 8: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

3 WAYS FLOW DIVERTERS

3 Ways Flow Diverters | Flow Diverters 7/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

VS 70 - VS 75 L7.00.U.J.W.V.X.Y.Z Max. pressure: 4500 psi (310 bar) Max. fl ow: 6,6 gpm (25 l/min) Ports: 1/4”Gas - SAE4

Circuit Transit position

3AW Circuit Transit position

3NW

Int. D.I.Ext. D.E.

IE

V Drain CircuitPressure

max 3A 3N 3626 psi (250bar) 3626 psi (250bar)

4500 psi (310bar) 4500 psi (310bar)

Spool types

Maximum performance Pressure drop

Mineral oil with 32 cSt viscosity, at 104°F (40°C) and 1450 psi (100 bar) pressure.

Internal leakage on C ports

MINIn3/min (cm3/ min)

MAXIn3/min (cm3/ min)

0,4 (7) 0,9 (15)

Weightslbs (kg)

2 (0.90)

2

A

U Ports(A)

1/4” G

SAE 4

Model

VS 70

VS 75

Tube - Plug Coil retainer nut Fixing screwsKey. 0,87: 14,8÷16,2 ft-lb

(ch. 22mm: 20÷22Nm)Dia 0,81: 3,7÷4,4 ft-lb

(Øe 20.5: 5÷6Nm)N°2 DIN 912-8.8 M5x50: 3,7÷4,4 ft-lb

(N°2 DIN 912-8.8 M5x50: 5÷6Nm)

Push-button manual override EPReference: 271-05098

Screwed manual override EFReference: LC04ZEF

_FJ

_PJ

CoilsGMA 6040

C36 StandardOn request electrically operated with explosion proof solenoid (ATEX)

Pag. 33

Pag. 37

Page 9: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

3 WAYS FLOW DIVERTERS

8/40 Flow Diverters | 3 Ways Flow Diverters

Bosch Rexroth Corp., RA 90811, edition: 2006-01

U X YL 7 0 0 _ _ _ _ _ _ _ _ _ _ _ W ZVJ

See page 7V DRAIN

Y

See page 7U PORTS J101F1P20*

OPERATEDELECTRICALLY OPERATED (DZ)ELECTRICALLY OPERATED + EFELECTRICALLY OPERATED + EPEL. OP. WITH EXPLOSION PROOF SOLENOID (AD)

00OBADOCACODOEOVOWOZ

00X

01

XXXXXXXXX

07

XXX

31

X

X

34

X

X

03

X

X

Without coil12V DC13V DC24V DC27V DC48V DC110V DC24V AC (RAC 21.5 DC)110V AC (RAC 98 DC)230V AC (RAC 207 DC)

X VOLTAGE Available connections

See page 7W CIRCUIT

* ON REQUEST (ATEX)

0001020307203134

Without coilWith coil without connectorWith connector DIN 43650AMP JuniorDT04-2P DEUTSCHCable 59,05 Inc. (1500 mm)

Cable 13,78 Inc. (350 mm)

Cable 13,78 Inc. (350 mm) + DT04-2P DEUTSCH

Y CONNECTION Z VERSION0V

STANDARDSEALS IN VITON

VS 70 - VS 75 L7.00.U.J.W.V.X.Y.Z

ORDERING CODE

02

XXXXXXXXX

20

X

X

XXXXX

Page 10: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

3 WAYS FLOW DIVERTERS

3 Ways Flow Diverters | Flow Diverters 9/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

VS 81/82/84/85 L7.05.U.J.W.V.X.Y.Z Max. pressure: 4500 psi (310 bar) Max. fl ow: 13,2-15,9 gpm (50-60 l/min) Ports: 3/8”G-1/2”G - SAE6-8

Maximum performance Pressure drop

Mineral oil with 32 cSt viscosity, at 104°F (40°C) and 1450 psi (100 bar) pressure.

Internal leakage on C ports

MINIn3/min (cm3/ min)

MAXIn3/min (cm3/ min)

0,6 (10) 1,2 (20)

34BC

U Ports (A)

3/8”G

1/2”G

SAE6

SAE8

Model

VS 81

VS 82

VS 84

VS 85Weightslbs (kg)

4,5 (2,06)

Tube-Plug Coil retainer nut Fixing screwsKey. 0,63-0,94: 16,2÷17,7 ft-lb

(ch. 16-24mm: 22÷24Nm)Dia.1,04: 3,7÷4,4 ft-lb

(D.26,5: 5÷6Nm)N°2 DIN 912-8,8 M6x40: 6,6÷7,4 ft-lb

(N°2 DIN 912-8,8 M6x40: 9÷10Nm)

Ports (A1)

1/4”G

1/4”G

SAE4

SAE4

Circuit Transit positionW Circuit Transit positionW3A

3N

3B

3C

3D

Int. D.I.Ext. D.E.

IE

V Drain CircuitPressure

max 3A 3B 3C 3D 3N 3626 psi (250bar) 3626 psi (250bar) 3626 psi (250bar) 3626 psi (250bar) 3626 psi (250bar)

4500 psi (310bar) 4500 psi (310bar) 4500 psi (310bar) 4500 psi (310bar) 4500 psi (310bar)

Spool types

CoilsGMA 6039

C48 StandardOn request electrically operated with explosion proof solenoid (ATEX)

Pag. 34

Pag. 36

Page 11: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

3 WAYS FLOW DIVERTERS

10/40 Flow Diverters | 3 Ways Flow Diverters

Bosch Rexroth Corp., RA 90811, edition: 2006-01

Push-button manual override EPReference: 271-05099

Screwed manual override EFReference: LC1DZEF

_FJ

_PJ

Oleopneumatic actuator OP

Reference: ####P1

J

00

X

H1

J

SG

XPush-turn manual actuator

Reference: 26-0243000 P. Max2900 (200)

P. Min58 (4)*

Pilot pressurepsi (bar)

* With external drain (DE).

With internal drain (DI), allow for pilot ratio 6,5:1. Example: at 1450 psi (100 bar) pressure (C1 or C2), will need a minimum pilot pres-sure of 1450 psi (100 bar):6,5 = 223,4 psi (15,4 bar)

0001020307203134

Without coilWith coil without connectorWith connector DIN 43650AMP JuniorDT04-2P DEUTSCHCable 59,05 Inc. (1500 mm)

Cable 13,78 Inc. (350 mm)

Cable 13,78 Inc. (350 mm) + DT04-2P DEUTSCH

Y CONNECTION Z VERSION0V

STANDARDSEALS IN VITON

U X YL 7 0 5 _ _ _ _ _ _ _ _ _ _ _ W ZVJ

VS 81/82/84/85 L7.05.U.J.W.V.X.Y.Z

Key. 1,06: 22,1÷24,3 ft-lb(ch. 27mm: 30÷33Nm)

Key. 1,18: 14,8÷16,2 ft-lb(ch. 30mm: 20÷22Nm)

Key. 0,98: 14,8÷16,2 ft-lb(ch. 25mm: 20÷22Nm)

ORDERING CODE

See page 9V DRAINSee page 9U PORTS J

111F1PP1H120*

OPERATEDELECTRICALLY OPERATED (DZ)ELECTRICALLY OPERATED + EFELECTRICALLY OPERATED + EPOLEOPNEUMATICALLY OPERATED (OP)MANUALLY OPERATED (MN)EL. OP. WITH EXPLOSION PROOF SOLENOID (AD)

See page 9W CIRCUIT

* ON REQUEST (ATEX)

Y

00OBADOCACODOEOVOWOZ

00X

01

XXXXX XXX

07

XXXX

31

X

X

34

X

X

03

X

X

Without coil12V DC13V DC24V DC27V DC48V DC110V DC24V AC (RAC 21.5 DC)110V AC (RAC 98 DC)230V AC (RAC 207 DC)

X VOLTAGE Available connections

02

XXXXX XXX

20

X

X

XXXXX

Page 12: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

3 WAYS FLOW DIVERTERS

3 Ways Flow Diverters | Flow Diverters 11/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

VS 91/92/95 L7.06.U.J.W.V.X.Y.Z Max. pressure: 4500 psi (310 bar) Max. fl ow: 37 gpm (140 l/min) Ports: 1/2”Gas-3/4”Gas - SAE12

Maximum performance Pressure drop

Mineral oil with 32 cSt viscosity, at 104°F (40°C) and 1450 psi (100 bar) pressure.

Internal leakage on C ports

MINIn3/min (cm3/ min)

MAXIn3/min (cm3/ min)

0,7 (12) 1,8 (30)

4U

1/2” Gas5 3/4” Gas

E SAE 12

1/4” Gas1/4” Gas

SAE 4

VS 91VS 92VS 95

Ports (A) Ports (A1) Model

Weightslbs (kg)

8,4 (3,8)

Circuit Transit positionW Circuit Transit positionW3A

3N

3B

3C

3D

Int. D.I.Ext. D.E.

IE

V Drain CircuitPressure

max 3A 3B 3C 3D 3N 3626 psi (250bar) 3626 psi (250bar) 3626 psi (250bar) 3626 psi (250bar) 3626 psi (250bar)

4500 psi (310bar) 4500 psi (310bar) 4500 psi (310bar) 4500 psi (310bar) 4500 psi (310bar)

Spool types

Coils C65 Standard Pag. 35

Page 13: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

3 WAYS FLOW DIVERTERS

12/40 Flow Diverters | 3 Ways Flow Diverters

Bosch Rexroth Corp., RA 90811, edition: 2006-01

L 7 0 6 _ _ _ _ _ _ _ _ _ _ _

VS 91/92/95 L7.06.U.J.W.V.X.Y.ZTube-Plug Coil retainer nut Fixing screws

Key. 0,75-1,06: 18,4÷19,9 ft-lb(ch. 19-27mm: 25÷27Nm)

Dia. 1,34: 5,2÷5,9 ft-lb(Ø.34: 7¸8Nm)

N°3 DIN 912-8,8 M8x45: 11,1÷11,8 ft-lb(N°3 DIN 912-8,8 M8x45: 15÷16Nm)

Push-button manual override EPReference: 281-0010

Screwed manual override EFReference: LC2DZEF

_FJ

_PJ

U X YW ZVJ

See page 11V DRAIN

Y

See page 11U PORTS J144F4P

OPERATEDELECTRICALLY OPERATED (DZ)ELECTRICALLY OPERATED + EFELECTRICALLY OPERATED + EP

00OBADOCACODOVOWOZ

00X

01

XXXXXXXX

07

XXX X

31

X

X

34

X

X

03

X

X

Without coil12V DC13V DC24V DC27V DC48V DC24V AC (RAC 21.5 DC)110V AC (RAC 98 DC)230V AC (RAC 207 DC)

X VOLTAGE Available connections

See page 11W CIRCUIT

00010203073134

Without coilWith coil without connectorWith connector DIN 43650AMP JuniorDT04-2P DEUTSCHCable 13,78 Inc. (350 mm)

Cable 13,78 Inc. (350 mm) + DT04-2P DEUTSCH

Y CONNECTION Z VERSION0V

STANDARDSEALS IN VITON

ORDERING CODE

02

XXXXXXXX

Page 14: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS FLOW DIVERTERS

6 Ways Flow Diverters | Flow Diverters 13/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

VS 120/125/129 L7.10.U.J.W.V.X.Y.Z Max. pressure: 4500 psi (310 bar) Max. fl ow: 6,6 gpm (25 l/min) Ports: 1/4”G - SAE4 - 1/4”G JIS B

Circuit Transit position Circuit Transit positionW W6A

6E

7A

7E

Maximum performance Pressure drop

Mineral oil with 32 cSt viscosity, at 104°F (40°C) and 1450 psi (100 bar) pressure.

Internal leakage on C ports

MINIn3/min (cm3/ min)

MAXIn3/min (cm3/ min)

0,4 (7) 0,9 (15)

Tube-Plug Coil retainer nut Fixing screwsKey. 0,87: 14,8÷16,2 ft-lb

(ch. 22mm: 20÷22Nm)Dia.0,81: 3,7÷4,4 ft-lb

(Ø.20,5: 5÷6Nm)N°2 DIN 912-8,8 M5x50: 3,7÷4,4 ft-lb

(N°2 DIN 912-8,8 M5x50: 5÷6Nm)

Int. D.I.Ext. D.E.

IE

V Drain CircuitPressure

max 6A 6E 7A 7E 3626 psi (250bar) 3626 psi (250bar) 3626 psi (250bar) 3626 psi (250bar)

4500 psi (310bar) 4500 psi (310bar) 4500 psi (310bar) 4500 psi (310bar)

Spool types

2

A

U Ports (A)

1/4” Gas

SAE 4

Model

VS 120

VS 125

Weightslbs (kg)

2,4 (1,1)

CoilsGMA 6040

C36 StandardOn request electrically operated with explosion proof solenoid (ATEX)

Pag. 33

Pag. 37

Page 15: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS FLOW DIVERTERS

14/40 Flow Diverters | 6 Ways Flow Diverters

Bosch Rexroth Corp., RA 90811, edition: 2006-01

VS 120/125/129 L7.10.U.J.W.V.X.Y.Z

U X YL 7 1 0 _ _ _ _ _ _ _ _ _ _ _ W ZVJORDERING CODE

J

U Ports (A)

1/4”G JIS B

Model

VS 129Weightslbs (kg) 2,4 (1,1)

Push-button manual override EPReference: 271-05098

Screwed manual override EFReference: LC04ZEF

_FJ

_PJ

Tube-Plug Coil retainer nut Fixing screwsKey. 0,87: 14,8÷16,2 ft-lb

(ch. 22mm: 20÷22Nm)Dia.0,81: 3,7÷4,4 ft-lb

(Ø.20,5: 5÷6Nm)N°2 DIN 912-8,8 M8: 6,6÷7,4 ft-lb

(N°2 DIN 912-8,8 M8: 9÷10Nm)

SEE PAGE 13V DRAIN

Y

SEE PAGE 13 - 14U PORTS J101F1P20*

OPERATEDELECTRICALLY OPERATED (Z)ELECTRICALLY OPERATED + EFELECTRICALLY OPERATED + EPEL. OP. WITH EXPLOSION PROOF SOLENOID (AD)

00OBADOCACODOEOVOWOZ

00X

02

XXXXXXXXX

07

XXX

31

X

X

34

X

X

03

X

X

WITHOUT COIL12V DC13V DC24V DC27V DC48V DC110V DC24V AC (RAC 21.5 DC)110V AC (RAC 98 DC)230V AC (RAC 207 DC)

X VOLTAGE AVAILABLE CONNECTIONS

SEE PAGE 13W CIRCUIT

* ON REQUEST (ATEX)

0001020307203134

WITHOUT COIL AND CONNECTORWITH COIL, WITHOUT CONNECTORWITH CONNECTOR DIN 43650AMP JUNIORDT04-2P DEUTSCHCable 59,05 Inc. (1500 mm)

Cable 13,78 Inc. (350 mm)

Cable 13,78 Inc. (350 mm) + DT04-2P DEUTSCH

Y CONNECTION Z VERSION0V

STANDARDSEALS IN VITON

01

XXXXXXXXX

20

X

X

XXXXX

Page 16: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS FLOW DIVERTERS

6 Ways Flow Diverters | Flow Diverters 15/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

VS 151/152/155 L7.21.U.J.W.V.X.Y.Z Max. pressure: 4500 psi (310 bar) Max. fl ow: 13,2-15,9 gpm (50-60 l/min) Ports: 3/8”G - 1/2”G - SAE8

Maximum performance Pressure drop

Mineral oil with 32 cSt viscosity, at 104°F (40°C) and 1450 psi (100 bar) pressure.

Internal leakage on C ports

MINIn3/min (cm3/ min)

MAXIn3/min (cm3/ min)

0,6 (10) 1,2 (20)

Tube-Plug Coil retainer nut Fixing screwsKey. 0,63-0,94: 16,2÷17,7 ft-lb

(ch. 16-24mm: 22÷24Nm)Dia.1,04: 3,7÷4,4 ft-lb

(Ø.26,5: 5÷6Nm)N°3 DIN 912-8,8 M6x40: 6,6÷7,4 ft-lb

(N°3 DIN 912-8,8 M6x40: 9÷10Nm)

3

4

C

U Ports (A)

3/8”G

1/2”G

SAE8

Model

VS 151

VS 152

VS 155Weightslbs (kg)

6,3 (2,85)

Ports (A1)

1/4”G

1/4”G

SAE4

Int. D.I.Ext. D.E.

IE

V Drain CircuitPressure

max 6A 6B 6E 6F 6G 3626 psi (250bar) 3626 psi (250bar) 3626 psi (250bar) 4500 psi (310bar) 4500 psi (310bar)

4500 psi (310bar) 4500 psi (310bar) 4500 psi (310bar) - -

Spool types

Circuit Transit positionW Circuit Transit positionW6A

6B

6E

6F

6G

CoilsGMA 6039

C48 StandardOn request electrically operated with explosion proof solenoid (ATEX)

Pag. 34

Pag. 36

Page 17: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS FLOW DIVERTERS

16/40 Flow Diverters | 6 Ways Flow Diverters

Bosch Rexroth Corp., RA 90811, edition: 2006-01

VS 151/152/155 L7.21.U.J.W.V.X.Y.Z

Push-button manual override EPReference: 271-05099

Screwed manual override EFReference: LC1DZEF

_FJ

_PJ

Oleopneumatic actuator OPReference: ####

P1

J

00

X

H1

J

SG

X Push-turn manual actuator

Reference: 26-0243000 P. Max2900 (200)

P. Min58 (4)*

Pilot pressurepsi (bar)

* With external drain (DE).

With internal drain (DI), allow for pilot ratio 6,5:1. Example: at 1450 psi (100 bar) pressure (C1 or C2), will need a minimum pilot pressure of 1450 psi (100 bar):6,5 = 223,4 psi (15,4 bar)

U X YL 7 2 1 _ _ _ _ _ _ _ _ _ _ _ W ZVJ

Key. 1,06: 22,1÷24,3 ft-lb(ch. 27mm: 30÷33Nm)

Key. 1,18: 14,8÷16,2 ft-lb(ch. 30mm: 20÷22Nm)

Key. 0,98: 14,8÷16,2 ft-lb(ch. 25mm: 20÷22Nm)

ORDERING CODE

SEE PAGE 15V DRAINSEE PAGE 15U PORTS J

111F1PP1H120*

OPERATEDELECTRICALLY OPERATED (DZ)ELECTRICALLY OPERATED + EFELECTRICALLY OPERATED + EPOLEOPNEUMATICALLY OPERATED (OP)MANUALLY OPERATED (MN)EL. OP. WITH EXPLOSION PROOF SOLENOID (AD)

SEE PAGE 15W CIRCUIT

* ON REQUEST (ATEX)

Y

00OBADOCACODOEOVOWOZ

00X

02

XXXXX XXX

07

XXXX

31

X

X

34

X

X

03

X

X

WITHOUT COIL12V DC13V DC24V DC27V DC48V DC110V DC24V AC (RAC 21.5 DC)110V AC (RAC 98 DC)230V AC (RAC 207 DC)

X VOLTAGE AVAILABLE CONNECTIONS

0001020307203134

WITHOUT COIL AND CONNECTORWITH COIL, WITHOUT CONNECTORWITH CONNECTOR DIN 43650AMP JUNIORDT04-2P DEUTSCHCable 59,05 Inc. (1500 mm)

Cable 13,78 Inc. (350 mm)

Cable 13,78 Inc. (350 mm) + DT04-2P DEUTSCH

Y CONNECTION Z VERSION0V

STANDARDSEALS IN VITON

01

XXXXX XXX

20

X

X

XXXXX

Page 18: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS FLOW DIVERTERS

6 Ways Flow Diverters | Flow Diverters 17/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

VS 161/165 L7.25.U.J.W.V.X.Y.Z Max. pressure: 4500 psi (310 bar) Max. fl ow: 13,2-15,9 gpm (50-60 l/min) Ports: 3/8”G - SAE8

Maximum performance Pressure drop

Mineral oil with 32 cSt viscosity, at 104°F (40°C) and 1450 psi (100 bar) pressure.

Internal leakage on C ports

MINIn3/min (cm3/ min)

MAXIn3/min (cm3/ min)

0,6 (10) 1,2 (20)

Tube-Plug Coil retainer nut Fixing screwsKey. 0,63-0,94: 16,2÷17,7 ft-lb

(ch. 16-24mm: 22÷24Nm)Dia.1,04: 3,7÷4,4 ft-lb

(Ø.26,5: 5÷6Nm)N°2 DIN 912-8,8 M8x70: 11,1÷11,8 ft-lb

(N°2 DIN 912-8,8 M8x70: 15÷16Nm)

Int. D.I.Ext. D.E.

IE

V Drain CircuitPressure

max 6A 6B 6E 6F 6G 3626 psi (250bar) 3626 psi (250bar) 3626 psi (250bar) 4500 psi (310bar) 4500 psi (310bar)

4500 psi (310bar) 4500 psi (310bar) 4500 psi (310bar) - -

Spool types

Circuit Transit positionW Circuit Transit positionW6A

6B

6E

6F

6G

3

C

U Ports (A)

3/8”G

SAE8

Model

VS 161

VS 165

Weightslbs (kg)

6,6 (3)

Ports (A1)

1/4”G

SAE4

CoilsGMA 6039

C48 StandardOn request electrically operated with explosion proof solenoid (ATEX)

Pag. 34

Pag. 36

Page 19: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS FLOW DIVERTERS

18/40 Flow Diverters | 6 Ways Flow Diverters

Bosch Rexroth Corp., RA 90811, edition: 2006-01

VS 161/165 L7.25.U.J.W.V.X.Y.Z

Push-button manual override EPReference: 271-05099

Screwed manual override EFReference: LC1DZEF

_FJ

_PJ

Oleopneumatic actuator OPReference: ####

P1

J

00

X

H1

J

SG

X Push-turn manual actuator

Reference: 26-0243000 P. Max2900 (200)

P. Min58 (4)*

Pilot pressurepsi (bar)

* With external drain (DE).

With internal drain (DI), allow for pilot ratio 6,5:1. Example: at 1450 psi (100 bar) pressure (C1 or C2), will need a minimum pilot pressure of 1450 psi (100 bar):6,5 = 223,4 psi (15,4 bar)

U X YL 7 2 5 _ _ _ _ _ _ _ _ _ _ _ W ZVJORDERING CODE

Key. 1,06: 22,1÷24,3 ft-lb(ch. 27mm: 30÷33Nm)

Key. 1,18: 14,8÷16,2 ft-lb(ch. 30mm: 20÷22Nm)

Key. 0,98: 14,8÷16,2 ft-lb(ch. 25mm: 20÷22Nm)

SEE PAGE 17V DRAINSEE PAGE 17U PORTS J

111F1PP1H120*

OPERATEDELECTRICALLY OPERATED (DZ)ELECTRICALLY OPERATED + EFELECTRICALLY OPERATED + EPOLEOPNEUMATICALLY OPERATED (OP)MANUALLY OPERATED (MN)EL. OP. WITH EXPLOSION PROOF SOLENOID (AD)

SEE PAGE 17W CIRCUIT

* ON REQUEST (ATEX)

Y

00OBADOCACODOEOVOWOZ

00X

02

XXXXX XXX

07

XXXX

31

X

X

34

X

X

03

X

X

WITHOUT COIL12V DC13V DC24V DC27V DC48V DC110V DC24V AC (RAC 21.5 DC)110V AC (RAC 98 DC)230V AC (RAC 207 DC)

X VOLTAGE AVAILABLE CONNECTIONS

0001020307203134

WITHOUT COIL AND CONNECTORWITH COIL, WITHOUT CONNECTORWITH CONNECTOR DIN 43650AMP JUNIORDT04-2P DEUTSCHCable 59,05 Inc. (1500 mm)

Cable 13,78 Inc. (350 mm)

Cable 13,78 Inc. (350 mm) + DT04-2P DEUTSCH

Y CONNECTION Z VERSION0V

STANDARDSEALS IN VITON

01

XXXXX XXX

20

X

X

XXXXX

Page 20: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS FLOW DIVERTERS

6 Ways Flow Diverters | Flow Diverters 19/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

VS 311/312/315 L7.53.U.J.W.V.X.Y.Z Max. pressure: 4500 psi (310 bar) Max. fl ow: 37 gpm (140 l/min) Ports: 1/2”G - 3/4”G - SAE12

Maximum performance Pressure drop

Mineral oil with 32 cSt viscosity, at 104°F (40°C) and 1450 psi (100 bar) pressure.

Internal leakage on C ports

MINIn3/min (cm3/ min)

MAXIn3/min (cm3/ min)

0,7 (12) 1,8 (30)

Int. D.I.Ext. D.E.

IE

V Drain CircuitPressure

max 6A 6B 6E 6F 6G 3626 psi (250bar) 3626 psi (250bar) 3626 psi (250bar) 4500 psi (310bar) 4500 psi (310bar)

4500 psi (310bar) 4500 psi (310bar) 4500 psi (310bar) - -

Spool types

Circuit Transit positionW Circuit Transit positionW6A

6B

6E

6F

6G

Coils C65 Standard Pag. 35

4

5

E

U Ports (A)

1/2”G

3/4”G

SAE12

Model

VS 311

VS 312

VS 315

Weightslbs (kg)

11,2 (5,1)

Ports (A1)

1/4”G

1/4”G

SAE4

Page 21: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS FLOW DIVERTERS

20/40 Flow Diverters | 6 Ways Flow Diverters

Bosch Rexroth Corp., RA 90811, edition: 2006-01

Tube-Plug Coil retainer nut Fixing screwsKey. 0,75-1,06: 18,4÷19,9 ft-lb

(ch. 19-27mm: 25÷27Nm)Dia.1,34: 5,2÷5,9 ft-lb

(Ø.34: 7÷8Nm)N°3 DIN 912-8,8 M8x45: 11,1÷11,8 ft-lb

(N°3 DIN 912-8,8 M8x45: 15÷16Nm)

VS 311/312/315 L7.53.U.J.W.V.X.Y.Z

Push-button manual override EPReference: 281-0010

Screwed manual override EFReference: LC2DZEF

_FJ

_PJ

U X YL 7 5 3 _ _ _ _ _ _ _ _ _ _ _ W ZVJORDERING CODE

SEE PAGE 19V DRAINSEE PAGE 19U PORTS J

144F4P

OPERATEDELECTRICALLY OPERATED (DZ)ELECTRICALLY OPERATED + EFELECTRICALLY OPERATED + EPSEE PAGE 19W CIRCUIT

Y

00OBADOCACODOVOWOZ

00X

02

XXXXXXXX

07

XXXX

31

X

X

34

X

X

03

X

X

WITHOUT COIL12V DC13V DC24V DC27V DC48V DC24V AC (RAC 21.5 DC)110V AC (RAC 98 DC)230V AC (RAC 207 DC)

X VOLTAGE AVAILABLE CONNECTIONS

0001020307203134

WITHOUT COIL AND CONNECTORWITH COIL, WITHOUT CONNECTORWITH CONNECTOR DIN 43650AMP JUNIORDT04-2P DEUTSCHCable 59,05 Inc. (1500 mm)

Cable 13,78 Inc. (350 mm)

Cable 13,78 Inc. (350 mm) + DT04-2P DEUTSCH

Y CONNECTION Z VERSION0V

STANDARDSEALS IN VITON

01

XXXXXXXX

20

X

X

XXXX

Page 22: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS BANKABLE FLOW DIVERTERS

6 Ways Bankable Flow Diverters | Flow Diverters 21/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

VS 120F - VS 125F L7.11.U.J.W.V.X.Y.Z Max. pressure: 4500 psi (310 bar) Max. fl ow: 5,3 gpm (20 l/min) Ports: 1/4”G - SAE4

Maximum performance Pressure drop

Mineral oil with 32 cSt viscosity, at 104°F (40°C) and 1450 psi (100 bar) pressure.

Internal leakage on C ports

MINIn3/min (cm3/ min)

MAXIn3/min (cm3/ min)

0,4 (7) 0,9 (15)

Circuit Transit position

6AW Circuit Transit position

6EW

Int. D.I.Ext. D.E.

IE

V Drain CircuitPressure

max 6A 6E 3626 psi (250bar) 3626 psi (250bar)

4500 psi (310bar) 4500 psi (310bar)

Spool types

CoilsGMA 6040

C36 StandardOn request electrically operated with explosion proof solenoid (ATEX)

Pag. 33

Pag. 37

Weightslbs (kg)

2,4 (1,10)2A

U Ports (A)

1/4” GasSAE4

Model

VS 120FVS 125F

Fixing (A1)

M 61/4”- 20 UNC

Page 23: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS BANKABLE FLOW DIVERTERS

22/40 Flow Diverters | 6 Ways Bankable Flow Diverters

Bosch Rexroth Corp., RA 90811, edition: 2006-01

VS 120F - VS 125F L7.11.U.J.W.V.X.Y.Z

Push-button manual override EPReference: 271-05098

Screwed manual override EFReference: LC04ZEF

_FJ

_PJ

Tube-Plug Coil retainer nut Fixing screwsKey. 0,87: 14,8÷16,2 ft-lb

(ch. 22mm: 20÷22Nm)Dia.0,81: 3,7÷4,4 ft-lb

(Ø.20,5: 5÷6Nm)DIN 912-8.8 M6: 6,6÷7,4 ft-lb

(DIN 912-8,8 M6: 9÷10Nm)

VS 120/125F-2 8 3,6 (92) 3,3 (85) 4,4 (6)

VS 120/125F-3 10 5,4 (138) 5,1 (130) 4,4 (6)

VS 120/125F-4 12 7,2 (184) 6,9 (175) 4,4 (6)

Model LInches (mm)

ScrewsInches (mm)

Maximum blocking torque

ft-lb (Nm)Port number

8 ways 10 ways 12 ways

Page 24: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS BANKABLE FLOW DIVERTERS

6 Ways Bankable Flow Diverters | Flow Diverters 23/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

VS 120F - VS 125F L7.11.U.J.W.V.X.Y.Z

U X YL 7 1 1 _ _ _ _ _ _ _ _ _ _ _ W ZVJ

SEE PAGE 21V DRAIN

Y

SEE PAGE 21U PORTS J101F1P20*

OPERATEDELECTRICALLY OPERATED (Z)ELECTRICALLY OPERATED + EFELECTRICALLY OPERATED + EPEL. OP. WITH EXPLOSION PROOF SOLENOID (AD)

00OBADOCACODOEOVOWOZ

00X

01

XXXXXXXXX

07

X

X

31

X

X

34

X

X

03

X

X

WITHOUT COIL12V DC13V DC24V DC27V DC48V DC110V DC24V AC (RAC 21.5 DC)110V AC (RAC 98 DC)230V AC (RAC 207 DC)

X VOLTAGE AVAILABLE CONNECTIONS

SEE PAGE 21W CIRCUIT

* ON REQUEST (ATEX)

0001020307203134

WITHOUT COIL AND CONNECTORWITH COIL WITHOUT CONNECTORWITH CONNECTOR DIN 43650AMP JUNIORDT04-2P DEUTSCHCable 59,05 Inc. (1500 mm)

Cable 13,78 Inc. (350 mm)

Cable 13,78 Inc. (350 mm) + DT04-2P DEUTSCH

Y CONNECTION Z VERSION0234

SINGLE ELEMENT2 FLANGED ELEMENTS3 FLANGED ELEMENTS4 FLANGED ELEMENTS

ORDERING CODE

02

XXXXXXXXX

20

X

X XXXXX

Page 25: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS BANKABLE FLOW DIVERTERS

24/40 Flow Diverters | 6 Ways Bankable Flow Diverters

Bosch Rexroth Corp., RA 90811, edition: 2006-01

VS 241/5/6F L7.32.U.J.W.V.X.Y.Z Max. pressure: 4500 psi (310 bar) Max. fl ow: 13,2 gpm (50 l/min) Ports: 3/8”G - SAE8 - M18X1,5

Maximum performance Pressure drop

Mineral oil with 32 cSt viscosity, at 104°F (40°C) and 1450 psi (100 bar) pressure.

Internal leakage on C ports

MINIn3/min (cm3/ min)

MAXIn3/min (cm3/ min)

0,6 (10) 1,8 (30)

3

C

Y

U Ports (A)

3/8”G

SAE8

M18X1,5

Weightslbs (kg)

7,4 (3,35)

Ports (A1)

1/4”G

SAE4

-

Model

VS 241F

VS 245F

VS 246F

Int. D.I.Ext. D.E.

IE

V Drain CircuitPressure

max 6B 6D 6E 6G 6H 3626 psi (250bar) 3626 psi (250bar) 3626 psi (250bar) 4500 psi (310bar) 4500 psi (310bar)

4500 psi (310bar) 4500 psi (310bar) 4500 psi (310bar) - -

Spool types

Circuit Transit positionW Circuit Transit positionW6B

6D

6E

6G

6H

CoilsGMA 6041

C48 StandardOn request electrically operated with explosion proof solenoid (ATEX)

Pag. 34

Pag. 38

Page 26: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS BANKABLE FLOW DIVERTERS

6 Ways Bankable Flow Diverters | Flow Diverters 25/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

VS 241/5/6F L7.32.U.J.W.V.X.Y.ZTube-Plug Coil retainer nut Fixing screws

Key. 0,63-1,06: 16,2÷17,7 ft-lb(ch. 16-27mm: 22÷24Nm)

Dia.1,04: 3,7÷4,4 ft-lb(Ø.26,5: 5÷6Nm)

DIN 912-8.8 M8x65: 11,1÷11,8 ft-lb(DIN 912-8,8 M8x65: 15÷16Nm)

Push-button manual override EPReference: 271-05099

Screwed manual override EFReference: LC1DZEF

_FJ

_PJ

CIR

CU

IT

Ports (D)

3/8” Gas

SAE8

Code

L7313610214SV00

L731C610214SV00

Description

Stackable element with cross pressure limiting valves on C1-C4.

EXAMPLE

P. maxpsi (bar)

3626 (250)

Qgpm (l/min)

13,2 (50)

Cartridge

VMD1.040.SV

Weights

Oleopneumatic actuator OP

Ref.: ####P1

J

00

X

H1

J

SG

X Push-turn manual actuatorRef.: 26-0243000 P. Max

200barP. Min4bar*

Pilot pressure

* With external drain (DE).

With internal drain (DI), allow for pilot ratio 6,5:1. Example: at 1450 psi (100 bar) pressure (C1, C2, C3 OR C4), will need a minimum pilot pressure of 1450 psi (100 bar):6,5 = 223,4 psi (15,4 bar)

Key. 1,06: 22,1÷24,3 ft-lb(ch. 27mm: 30÷33Nm)

Key. 1,18: 14,8÷16,2 ft-lb(ch. 30mm: 20÷22Nm)

Key. 0,98: 14,8÷16,2 ft-lb(ch. 25mm: 20÷22Nm)

3,1 lbs (1,4 kg)

Page 27: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS BANKABLE FLOW DIVERTERS

26/40 Flow Diverters | 6 Ways Bankable Flow Diverters

Bosch Rexroth Corp., RA 90811, edition: 2006-01

VS 241/5/6F L7.32.U.J.W.V.X.Y.Z

8 ways 10 ways 12 ways 14 ways

VS 241/5/6F-2 8 5,2 (132) M8x125 (v) 12,5 (17)

VS 241/5/6F-3 10 7,8 (198) M8x190 (v) 12,5 (17)

VS 241/5/6F-4 12 10,4 (264) M8x270 (t) 12,5 (17)

VS 241/5/6F-5 14 13,0 (330) M8x330 (t) 12,5 (17)

Model L

Inches (mm)

Screws - Tie rods Maximum blocking torque

ft-lb (Nm)

Port number

U X YL 7 3 2 _ _ _ _ _ _ _ _ _ _ _ W ZVJORDERING CODE

0001020307203134

Without coilWith coil without connectorWith connector DIN 43650AMP JuniorDT04-2P DEUTSCHCable 59,05 Inc. (1500 mm)

Cable 13,78 Inc. (350 mm)

Cable 13,78 Inc. (350 mm) + DT04-2P DEUTSCH

Y CONNECTION Z VERSION02345

SINGLE ELEMENT2 FLANGED ELEMENTS3 FLANGED ELEMENTS4 FLANGED ELEMENTS5 FLANGED ELEMENTS

Y

00OBADOCACODOEOVOWOZ

00X

01

XXXXXXXXX

07

X

X

31

X

X

34

X

X

03

X

X

WITHOUT COIL12V DC13V DC24V DC27V DC48V DC110V DC24V AC (RAC 21.5 DC)110V AC (RAC 98 DC)230V AC (RAC 207 DC)

X VOLTAGE AVAILABLE CONNECTIONS

02

XXXXXXXXX

20

X

X XXXXX

SEE PAGE 24V DRAINSEE PAGE 24U PORTS

SEE PAGE 24W CIRCUIT

111F1PP1H120*

ELECTRICALLY OPERATED (DZ)ELECTRICALLY OPERATED + EFELECTRICALLY OPERATED + EPOLEOPNEUMATICALLY OPERATED (OP)MANUALLY OPERATED (MN)EL. OP. WITH EXPLOSION PROOF SOLENOID (AD)

J OPERATED

* ON REQUEST (ATEX)

Page 28: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS BANKABLE FLOW DIVERTERS

6 Ways Bankable Flow Diverters | Flow Diverters 27/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

VS 281/5/6F L7.45.U.J.W.V.X.Y.Z Max. pressure: 4500 psi (310 bar) Max. fl ow: 24gpm (90 l/min) Ports: 1/2” Gas - SAE10 - M18x1,5

Maximum performance Pressure drop

Mineral oil with 32 cSt viscosity, at 104°F (40°C) and 1450psi (100bar) pressure.Internal leakage on C ports

MINin3/min (cm3/min)

MAXin3/ min (cm3/min)

0,6 (10) 1,8 (30)

Weights 9,15 lbs (4.15 kg)

4U Ports

(A)

1/2” Gas

D SAE 10

Y M18x1,5

Model

VS281F

VS285F

VS286F

Ports (A1)

1/4” Gas

SAE 4

-

Int. D.I.Ext. D.E.

IE

V Drain CircuitPressure

max 6B 6D 6E 6G 6H 3626 psi (250bar) 3626 psi (250bar) 3626 psi (250bar) 4500 psi (310bar) 4500 psi (310bar)

4500 psi (310bar) 4500 psi (310bar) 4500 psi (310bar) - -

Spool types

Circuit Transit positionW Circuit Transit positionW6B

6D

6E

6G

6H

Coils C65 Standard Pag. 35

Page 29: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS BANKABLE FLOW DIVERTERS

28/40 Flow Diverters | 6 Ways Bankable Flow Diverters

Bosch Rexroth Corp., RA 90811, edition: 2006-01

Tube-Plug Retainer nut Fixing screwsKey. 0,75-1,06 In: 18,4÷19,9 ft-lb

(ch. 19-27mm: 25÷27Nm)Dia.1,34: 5,2÷5,9 ft-lb

(Ø.34: 7÷8 Nm)DIN 912-8.8 M8x65: 11,1÷11,8 ft-lb

(DIN 912-8.8 M8x65: 15÷16Nm)

VS 281/5/6F L7.45.U.J.W.V.X.Y.Z

Push-button manual override EPReference: 281-0010

Screwed manual override EFReference: LC2DZEF

_FJ

_PJ

CIR

CU

IT Ports (D)

1/2” Gas

SAE10

Code

L7404610214SV00

L740D610214SV00

Description

Modular element with cross pressure limi-ting valves on C1-C4.

EXAMPLE

P. maxpsi(bar)

3626(250)

Qgpm(l/min)

18,5(70)

Weights 3,1 lbs(1.40 kg)

Cartridge

VMD1.070.SV

* With external drain (DE).

Oleopneumatic actuator OPReference: ####

P1

J

00

X

H1

J

SG

X Push-turn manual actuator

Ref.: 26-0243000P. Max

2900 psi (200bar)

P. Min58 psi*(4bar)

Pilot pressure

With internal drain (DI), allow for pilot ratio 6,5:1. Example: at 1450 psi (100 bar) pressure (C1,C2,C3,C4), will need a minimum pilot pressure of 1450 (100 bar):6,5 = 223,4 psi (15,4 bar).

Key. 1,06: 22,1÷24,3 ft-lb(ch. 27mm: 30÷33Nm)

Key. 1,18: 14,8÷16,2 ft-lb(ch. 30mm: 20÷22Nm)

Key. 0,98: 14,8÷16,2 ft-lb(ch. 25mm: 20÷22Nm)

Page 30: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS BANKABLE FLOW DIVERTERS

6 Ways Bankable Flow Diverters | Flow Diverters 29/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

VS 281/5/6F L7.45.U.J.W.V.X.Y.Z

8 ways 10 ways 12 ways 14 ways

VS 281/5/6F-2 8 5,2 (132) M8x125 (v) 12,5 (17)

VS 281/5/6F-3 10 7,8 (198) M8x190 (v) 12,5 (17)

VS 281/5/6F-4 12 10,4 (264) M8x270 (t) 12,5 (17)

VS 281/5/6F-5 14 13,0 (330) M8x330 (t) 12,5 (17)

Model L

Inches (mm)

Screws - Tie rods Maximum blocking torque

ft-lb (Nm)

Port number

U X YL 7 4 5 _ _ _ _ _ _ _ _ _ _ _ W ZVJORDERING CODE

000103073134

Without coilWith coil without connectorAMP JuniorDT04-2P DEUTSCHCable 13,78 Inc. (350 mm)

Cable 13,78 Inc. (350 mm) + DT04-2P DEUTSCH

Y CONNECTION Z VERSION02345

SINGLE ELEMENT2 FLANGED ELEMENTS3 FLANGED ELEMENTS4 FLANGED ELEMENTS5 FLANGED ELEMENTS

SEE PAGE 28V DRAIN

Y

SEE PAGE 28U PORTS J131F1PP1H1

OPERATEDELECTRICALLY OPERATED (DZ)ELECTRICALLY OPERATED + EFELECTRICALLY OPERATED + EPOLEOPNEUMATICALLY OPERATED (OP)MANUALLY OPERATED (MN)

00OBADOCACODOVOWOZ

00X

01

XXXXXXXX

07

XXXX

31

X

X

34

X

X

03

X

X

Without coil12V DC13V DC24V DC27V DC48V DC24V AC (RAC 21.5 DC)110V AC (RAC 98 DC)230V AC (RAC 207 DC)

X VOLTAGE Available connections

SEE PAGE 28W CIRCUIT

02

XXXXXXXX

Page 31: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS PILOTED FLOW DIVERTERS

30/40 Flow Diverters | 6 Ways Piloted Flow Diverters

Bosch Rexroth Corp., RA 90811, edition: 2006-01

VS 400 L7.55.6.J.W.V.X.Y.Z Max. pressure: 4500 psi (310 bar) Max. fl ow: 58,1 gpm (220 l/min) Ports: Only available in 1”Gas

Circuit Transit positionW

6B

J00

10

1D

Pilot

Without pilot valve

With LC04-Z-Y301 pilot valve

With LC04-Z-M501 pilot valve (Detent)

Minimum pilot pressure 261 psi (18 bar). (With internal pilot, switching pressure between P1 and P2 ≥ 261 psi (18 bar).

V 1(P.I. - D.I.)

2(P.E. - D.E.)

3(P.E. - D.I.)

4(P.I. - D.E.)

P. M

ax.

Mineral oil with 32 cSt viscosity, at 104°F (40°C) and 1450 psi (100 bar) pressure.

Internal leakage on C ports

MINIn3/min (cm3/ min)

MAXIn3/min (cm3/ min)

1,2 (20) 3,6 (60)

Maximum performance Pressure drop

Connection: 4500 psi (310 bar)

Drain: 3626 psi (210 bar)

Pilot: 4500 psi (310 bar)

Connection: 4500 psi (310 bar)

Drain: 3626 psi (210 bar)

Pilot: 4500 psi (310 bar)

Connection: 4500 psi (310 bar)

Drain: 3626 psi (210 bar)

Pilot: 4500 psi (310 bar)

Connection: 4500 psi (310 bar)

Drain: 3626 psi (210 bar)

Pilot: 4500 psi (310 bar)

CoilsGMA 6040

C36 StandardOn request electrically operated with explosion proof solenoid (ATEX)

Pag. 33

Pag. 37

Page 32: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

6 WAYS PILOTED FLOW DIVERTERS

6 Ways Piloted Flow Diverters | Flow Diverters 31/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

VS 400 L7.55.6.J.W.V.X.Y.Z

0001020307203134

WITHOUT COIL AND CONNECTORWITH COIL WITHOUT CONNECTORWITH CONNECTOR DIN 43650AMP JUNIORDT04-2P DEUTSCHCable 59,05 Inc. (1500 mm)

Cable 13,78 Inc. (350 mm)

Cable 13,78 Inc. (350 mm) + DT04-2P DEUTSCH

Y CONNECTION

X VOLTAGE00OBADOCACODOEOVOWOZ

WITHOUT COIL12V DC13V DC24V DC27V DC48V DC110V DC24V AC (RAC 21.5 DC)110V AC (RAC 98 DC)230V AC (RAC 207 DC)

SEE PAGE 30PILOT SEE PAGE 30W CIRCUITJ

INTERNAL PILOT SYSTEM - INTERNAL DRAIN SYSTEMEXTERNAL PILOT SYSTEM - EXTERNAL DRAIN SYSTEMEXTERNAL PILOT SYSTEM - INTERNAL DRAIN SYSTEMINTERNAL PILOT SYSTEM - EXTERNAL DRAIN SYSTEM

V PILOT AND DRAIN POSSIBILITIES1234

Z VERSION0V

STANDARDSEALS IN VITON

00X

02

XXXXXXXXX

31

X

X

34

X

X

07

XXX

AVAILABLE CONNECTIONS

Fixing screwsDIN 912-8.8 M8x95: 11,1÷11,8 ft-lb

(DIN 912-8,8 M8x95: 15÷16Nm)

Weights 33,5 lbs(15,2 kg)

X YL 7 5 5 6 _ _ _ _ _ _ _ _ _ _ W ZVJORDERING CODE

01

XXXXXXXXX

20

X

X XXXXX

Page 33: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

32/40 Flow Diverters | Handles

Bosch Rexroth Corp., RA 90811, edition: 2006-01

HANDLES

ORDERING CODE VSLVPCED VGENERAL SPECIFICATIONS• Possible insertion of push buttons: 1,2,4,6.• PVC cables with diameter from 0,03 Inc2. (0,5 mm2) and 256 wires for cable, standard wire lenght 13,78 Inc. (350 mm) from the hand-le’s base.• Cables terminal supplied without lead-in wire. • Max current on contacts: 3 Ampere.• Safety push button on request.• Electrical life: 106 cycles (1 cycle = 2 sec.“ON” / 2 sec. OFF with current=3A voltage=12VDC and with arc suppressor diode) 105 cycles if used with with current=3A voltage=12VDC and with direct connection.• Mechanical Life: 106 cycles.

V 1 2 4 6

Pu

sh

bu

tto

ns

Electrical wiring diagram

Maximum current at contacts: 13A

ORDERING CODE LV-622930

LV - PCED - 6 - S

BLU

E

RE

D

GR

EY

BLA

CK

RE

D

YE

LLO

W

WH

ITE

RE

D

GR

EE

N

RE

D

YE

LLO

W/G

RE

EN

LV - PCED - 4 - S

BLU

E

RE

D

GR

EY

WH

ITE

RE

D

GR

EE

N

RE

D

YE

LLO

W/G

RE

EN

LV - PCED - 1 - S LV - PCED - 2 - S

RE

D

GR

EE

N

YE

LLO

W/G

RE

EN

RE

D

YE

LLO

W

YE

LLO

W/G

RE

EN

BLA

CK

RE

D

RE

D

Page 34: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

COILS

Coils | Flow Diverters 33/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

C 36

Weight: 0,46 lbs. (0,21 kg) - Insulation Class: HRelative duty factor: ED 100% only if the room temperature does not exceed 104°F (40°C) ambient temperature.Permissing voltage fl uctuation: +5% -10% of the nominal.Available voltages: Look at table. On request different voltages can be supplied.Standard Connections: DIN 43650, ISO 4400.Low voltage directives EEC 73/23/CEE and 89/336/CEE .Versions with sheated cables as well as with Deutsch and AMP JUNIOR connectors are equipped with bi-directional diode.Protection Class according to DIN 40050: coil correctly assembled with O’ring and retainer:- IP65 with AMP JUNIOR and DIN 43650 connector, if assembled with rubber sealings and fi xing screw is properly tightened.- IP69k for versions with Deutsch connector.

C36 01 C36 31C36 34

C36 07C36 03

10J

1_

271-0510 C3601 12DC DIN 43650 - ISO 4400 12 DC 12 VDC 26 2,15 5,5

271-0510002 C3631 12DC CABLES 12 DC 12 VDC 26 2,15 5,5

271-05102 C3603 12DC AMP JUNIOR 12 DC 12 VDC 26 2,15 5,5

271-0510004 C3634 12DC CABLE + DEUTSCH 12 DC 12 VDC 26 2,15 5,5

271-0510207 C3607 12DC DEUTSCH DT 04-2P 12 DC 12 VDC 26 2,15 5,5

271-05104 C3601 13DC DIN 43650 - ISO 4400 13 DC 13 VDC 26 2,00 6,5

271-0510208 C3607 13DC DEUTSCH DT 04-2P 13 DC 13 VDC 26 2,00 6,5

271-0511 C3601 24DC DIN 43650 - ISO 4400 24 DC 24 VDC 26 1,10 22

271-0511002 C3631 24DC CABLES 24 DC 24 VDC 26 1,10 22

271-05112 C3603 24DC AMP JUNIOR 24 DC 24 VDC 26 1,10 22

271-0511004 C3634 24DC CABLE + DEUTSCH 24 DC 24 VDC 26 1,10 22

271-0511207 C3607 24DC DEUTSCH DT 04-2P 24 DC 24 VDC 26 1,10 22

271-051101 C3601 27DC DIN 43650 - ISO 4400 27 DC 27 VDC 26 1,00 28

271-0512 C3601 48DC DIN 43650 - ISO 4400 48 DC V 48 DC 26 0,54 89

271-0514 C3601 110DC DIN 43650 - ISO 4400 110 DC V 110 DC 29 0,27 413

271-05110 C3601 24-50/60Hz RAC DIN 43650 - ISO 4400 21,5 DC V 21.5 DC 26 1,20 18

271-0513 C3601 110-50/60Hz RAC DIN 43650 - ISO 4400 98 DC V 98 DC 29 0,29 338

271-0515 C3601 230-50/60Hz RAC DIN 43650 - ISO 4400 207 DC V 207 DC 29 0,14 1430

Reference Model Connection Nominal voltage

Volt

Marking Power

watt

Nominal currentampere

Resistance

± 7%

ΩT=68°F

(20°C)

Page 35: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

COILS

34/40 Flow Diverters | Coils

Bosch Rexroth Corp., RA 90811, edition: 2006-01

C 48

Weight : 1,1 lbs. (0,500 kg) - Insulation Class: H Working Duty: ED 100% only if the room temperature does not exceed 104°F (40°C) .Inlet voltage: should not exceed +5% / -10% of the nominal value.Available voltages: Look at table. On request different voltages can be supplied.Low voltage: conforms to the 73/23/CEE and 89/336/CEE directives. Standard connections: DIN 43650-ISO 4400. Versions with sheated cables as well as with Deutsch and AMP JUNIOR connectors are equipped with bi-directional diode.Protection Class according to DIN 40050: only if the coil is assembled correctly with O’ring and retainer: - IP65 with DIN 43650 connector, only if they are assembled with rubber sealings and the fi xing screw is properly tightened.- IP69k for versions with Deutsch connector.

271-052001

C4831 24DC

CABLES + DEUTSCH 12 DC 12 VDC 36 3.01 4,0

Connection Nominal voltage

volt

Marking Power

watt

Nominal currentampere

ResistanceΩ

± 7%

271-052000 C4831 12DC CABLES 12 DC 12 VDC 36 3.01 4,0271-0520 C4801 12DC DIN 43650 - ISO 4400 12 DC 12 VDC 36 3.01 4,0

271-052005 CABLES 24 DC 24 VDC 36 1.53 16,0271-0521 C4801 24DC DIN 43650 - ISO 4400 24 DC 24 VDC 36 1.53 16,0

C4834 12DC

271-052006 C4834 24DC CABLES + DEUTSCH 24 DC 24 VDC 36 1.53 16,0

271-052004 DEUTSCH DT04-2P 12 DC 12 VDC 36 3.01 4,0C4807 12DC

271-052009 C4807 24DC DEUTSCH DT04-2P 24 DC 24 VDC 36 1.53 16,0

271-052008 C4807 27DC DEUTSCH DT04-2P 27 DC 27 VDC 36 1.32 20,5

271-0520005 AMP JUNIOR 12 DC 12 VDC 36 3.01 4,0C4803 12DC

271-0520055 C4803 24DC AMP JUNIOR 24 DC 24 VDC 36 1.53 16,0

271-0525 C4801 230-50/60RAC DIN 43650 - ISO 4400 207 DC 207 DC 36 0.17 1163,0271-0524 C4801 110-50/60RAC DIN 43650 - ISO 4400 98 DC 98 VDC 36 0.37 261,0271-0523 C4801 24-50/60RAC DIN 43650 - ISO 4400 21,5 DC 21,5 VDC 36 1.70 12,0

271-05212 C4801 27DC DIN 43650 - ISO 4400 27 DC 27 VDC 36 1.32 20,5271-0522 C4801 48DC DIN 43650 - ISO 4400 48 DC 48 VDC 36 0.75 63,6

Reference Model

271-052007 DEUTSCH DT04-2P 13 DC 13 VDC 36 2.77 4,7C4807 13DC271-0520045 C4801 13DC DIN 43650 - ISO 4400 13 DC 13 VDC 36 2.77 4,7

C48 01 C48 34C48 07 C48 31C48 03

T=68°F (20°C)

11J

1_

Page 36: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

COILS

Coils | Flow Diverters 35/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

C 65Weight: 1,2 kg - Insulation Class: H - Working Duty: ED 100% only if the room temperature does not exceed 104°F (40°C).Inlet voltage: should not exceed +5% / -10% of the nominal value.Available voltages: Look at table. On request different voltages can be supplied.Low voltage: conforms to the 73/23/CEE and 89/336/CEE directives. Standard connections: DIN 43650-ISO 4400. Versions with sheated cables as well as with Deutsch and AMP JUNIOR connector are equipped with bi-directional diode.Protection Class according to DIN 40050: only if the coil is assembled correctly with O’ring and retainer: - IP65 with DIN 43650 connector, only if it is assembled with rubber sealings and the fi xing screw is properly tightened.- IP69k for versions with Deutsch connector.

C65 07 C65 34 C65 3165 03C65 01

281-0617 C6501 12DC DIN 43650 - ISO 4400 12 DC 12 VDC 44 3.60 3.2

281-06196 C6534 24DC CABLE + DEUTSCH 24 DC 24 VDC 44 1.80 12.8

281-0618 C6501 24DC DIN 43650 - ISO 4400 24 DC 24 VDC 44 1.80 12.8

± 7%

281-06191 C6534 12DC CABLE + DEUTSCH 12 DC 12 VDC 44 3.60 3.2

281-06190 C6531 12DC CABLES 12 DC 12 VDC 44 3.60 3.2

281-06195 C6531 24DC CABLES 24 DC 24 VDC 44 1.80 12.8

281-061800 C6501 27DC DIN 43650 - ISO 4400 27 DC 27 VDC 44 1.60 16.9

281-0624 C6501 230 50 RAC DIN 43650 - ISO 4400 207 DC 207 VDC 44 0.21 997

281-0623 C6501 110 50 RAC DIN 43650 - ISO 4400 98 DC 98 VDC 44 0.45 98

281-0622 C6501 24 50 RAC DIN 43650 - ISO 4400 21.5 DC 21.5 VDC 44 2.00 11

281-0621 C6501 48DC DIN 43650 - ISO 4400 48 DC 48 VDC 44 0.90 50.5

281-06194 C6507 12DC DEUTSCH DT04-2P 12 DC 12 VDC 44 3.60 3.2

281-06197 C6507 24DC DEUTSCH DT04-2P 24 DC 24 VDC 44 1.80 12.8

281-061700 C6501 13DC DIN 43650 - ISO 4400 13 DC 13 VDC 44 3.40 3.6

281-0631 C6503 12DC AMP JUNIOR 12 DC 12 VDC 44 3.60 3.2

281-0632 C6503 24DC AMP JUNIOR 24 DC 24 VDC 44 1.80 12.8

281-06198 C6507 13DC DEUTSCH DT04-2P 13 DC 13 VDC 44 3.40 3.9

281-06199 C6507 27DC DEUTSCH DT04-2P 27 DC 27 VDC 44 1.60 16.7

Connection Nominal voltage

volt

Marking Power

watt

Nominal currentampere

ResistanceΩ

Reference Model

T=68°F (20°C)

14J

4_

Page 37: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

36/40

Bosch Rexroth Corp., RA 90811, edition: 2006-01

Flow Diverters | Explostion Proof Solenoid

GMA 6039

Certifi cate: CESI 03 ATEX 212 (CESI n° 0722 directive 94/9/CE).Protective system: EX II 2 GEExd II CT5.Weight: 2,31 lbs (1,05 kg).Solenoids GMA 6039, meant to be fed with DC current.For AC versions the coils in their interior a rectifi er bridge and can be used with 50 and 60Hz frequencies.The coils are supplied with a 3-pole cable with wire section of 0,002 inc2 (1,5 mm2) protected by an external sheath in silicon rubber.Functionality intermittence: ED100% if the ambient temperature does not exceed 104°F.Protection Class: IP 67 according to DIN 40050.Feeding voltage: must not exceed +5% / -10% of the nominal value.

Mounting of the coil retainer nutsThe coil is blocked to the tube by screwing the retainer nut Key 0,94 (ch. 24) with the necessary blocking torque 4,4-5,2 ft-lb (6-7 Nm). The retainer nut then needs to be blocked by the threaded screw. If the coil is used in different conditions, the conformity of the coil’s construction to the rules cannot be guaranteed.

EXPLOSION PROOF SOLENOID

20

J

20

Y

27-0510

27-0512

27-0514

27-0516

27-0522

27-0526

27-0529

GMA6039 12DC

GMA6039 24DC

GMA6039 48DC

GMA6039 110DC

GMA6039 24V- 50/60Hz

GMA6039 110V- 50/60Hz

GMA6039 230V- 50/60Hz

12V DC

24V DC

48V DC

110V DC

24 VAC - 50/60Hz

110 VAC - 50/60Hz

230 VAC - 50/60Hz

12,8

12,7

12,7

12,4

12

12

11

1.06

0.57

0.27

0.11

0.56

0.12

0.05

11.35

45.3

181

970

37.8

794

3780

± 7%

Nominal voltagevolt

Power

watt

Nominal currentampere

ResistanceΩ

Reference Model

T=68°F (20°C)

Page 38: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

37/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

Explostion Proof Solenoid | Flow Diverters

GMA 6040

Certifi cate: CESI 03 ATEX 212 (CESI n° 0722 directive 94/9/CE).Protective system: EX II 2 GEExd II CT5.Weight: 2,31 lbs (1,05 kg).Solenoids GMA 6039, meant to be fed with DC current.For AC versions the coils in their interior a rectifi er bridge and can be used with 50 and 60Hz frequencies.The coils are supplied with a 3-pole cable with wire section of 0,002 inc2 (1,5 mm2) protected by an external sheath in silicon rubber.Functionality intermittence: ED100% if the ambient temperature does not exceed 104°F.Protection Class: IP 67 according to DIN 40050.Feeding voltage: must not exceed +5% / -10% of the nominal value.

Mounting of the coil retainer nutsThe coil is blocked to the tube by screwing the retainer nut Key 0,94 (ch24) with the necessary blocking torque 4,4-5,2 ft-lb (6-7 Nm). The retainer nut then needs to be blocked by the threaded screw. If the coil is used in different conditions, the conformity of the coil’s construction to the rules cannot be guaranteed.

27-0540

27-0542

27-0544

27-0546

27-0552

27-0556

27-0559

GMA6040 12DC

GMA6040 24DC

GMA6040 48DC

GMA6040 110DC

GMA6040 24V- 50/60Hz

GMA6040 110V- 50/60Hz

GMA6040 230V- 50/60Hz

12V DC

24V DC

48V DC

110V DC

24 VAC - 50/60Hz

110 VAC - 50/60Hz

230 VAC - 50/60Hz

12,8

12,7

12,7

12,4

12

12

11

1.06

0.57

0.27

0.11

0.56

0.12

0.05

11.35

45.3

181

970

37.8

794

3780

± 7%

Nominal voltagevolt

Power

watt

Nominal currentampere

ResistanceΩ

Reference Model

T=68°F (20°C)

20

J

20

Y

EXPLOSION PROOF SOLENOID

Page 39: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

38/40

Bosch Rexroth Corp., RA 90811, edition: 2006-01

Flow Diverters | Explosion Proof Solenoid

Certifi cate: CESI 03 ATEX 212 (CESI n° 0722 directive 94/9/CE).Protective system: EX II 2 GEExd II CT5.Weight: 2,31 lbs (1,05 kg).Solenoids GMA 6039, meant to be fed with DC current.For AC versions the coils in their interior a rectifi er bridge and can be used with 50 and 60Hz frequencies.The coils are supplied with a 3-pole cable with wire section of 0,002 inc2 (1,5 mm2) protected by an external sheath in silicon rubber.Functionality intermittence: ED100% if the ambient temperature does not exceed 104°F.Protection Class: IP 67 according to DIN 40050.Feeding voltage: must not exceed +5% / -10% of the nominal value.

Mounting of the coil retainer nutsThe coil is blocked to the tube by screwing the retainer nut Key 0,94 (ch24) with the necessary blocking torque 4,4-5,2 ft-lb (6-7 Nm). The retainer nut then needs to be blocked by the threaded screw. If the coil is used in different conditions, the conformity of the coil’s construction to the rules cannot be guaran-teed.

GMA 6041

EXPLOSION PROOF SOLENOID

27-0547

27-0548

GMA6041 12DC

GMA6041 24DC

12V DC

24V DC

12,8

12,7

1.06

0.57

11.35

45.3

± 7%

Nominal voltagevolt

Power

watt

Nominal currentampere

ResistanceΩ

Reference Model

T=68°F (20°C)

20

J

20

Y

Page 40: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

39/40

RA 90811, edition: 2006-01, Bosch Rexroth Corp.

Explosion Proof Solenoid | Flow Diverters

These connectors are standardized DIN 43650 – ISO 4400. Four versions are available: - standard version MPM 182-09 - version with rectifi er MPM 532-09 RAC - version with LED (which indicates presence of voltage) MPM 182-LED-T-A1 - version with VDR (device which cuts over-voltage in input) MPM 182-09-G-DO-2-1.For a correct functioning and to guarantee the level of protection IP 65, it is essential to assemble connectors with rubber seals and have the mounting screw fully screwed in.

MPM 532-09 RACMPM 182-09MPM 182-LED-T-A1

MPM 182-09-G-DO-2-1

Number of poles 2 + groundRated current capacity 10 AMax current capacity 16 AContact resistance 4 mΩ

Max wire section area 0,02 Inc². (1.5 mm²)

Cable gland thread Pg 9 Din 40430Protection class IP65 DIN 40050Electrical insulation VDE 0110Tightening torque 2,2÷3 ft-lb (3÷4 Nm)

29-0001 MPM 182-09 GREY 29-0002 MPM 182-09 BLACK 29-0003/A MPM 532-09 RAC GREY 29-0003 MPM 532-09 RAC BLACK 29-0004 MPM 182-LED-T-A1 12DC/AC 29-0005 MPM 182-LED-T-A1 24DC/AC 29-0006 MPM 182-LED-T-A1 48DC/AC 29-0007 MPM 182-LED-T-A1 110DC/AC 29-0008 MPM 182-LED-T-A1 230DC/AC 29-00010 MPM 182-09-G-DO-2-1 12DC con VDR 29-00011 MPM 182-09-G-DO-2-1 24DC con VDR 29-00013 CONN. MPM 183-11-G/GREY (4 CONTACTS)

29-00023 CONN. MPM 183-11-N/BLACK (4 CONTACTS)

Reference Model

02

Y

CONNECTORS

Page 41: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

Rev. 11.05

40/40

Bosch Rexroth Corp., RA 90811, edition: 2006-01

Flow Diverters | Typical Applications

FLOW DIVERTERS

TYPICAL APPLICATIONS

We design devlop and supply fl ow diverters to the mobile industry with fl ow rates to 220 l/min and the possibility of choosing from 3 to 14 ways (obtainable using modular diverters).

Comparated with the traditional solution, which uses normal one or two lever directional valves, or valves with remote con-trols, the fl ow diverters we produced have innumerable practical advantages.

-The diverter may be positioned next to the control cylinders, thus making pipe connections easier and cheaper.- Using a push-button control placed on the directional valve lever and electrically connecting the solenoid(s), it is possible,

through an electrical signal, to control the required cylinder.- The operator can move the distributor lever and various handling movements at the same time with only one hand, by using

electrical buttons positioned on the handgrip, hence leaving the other hand free to carry out other operations.We currently offer a wide range of diverters: from the single diverters 3 and 6 ways, to modular diverters from to 14 ways,

with electric, air/oil and manual operated, with GAS or SAE ports.

Page 42: Flow Diverters - Hydba · 2019. 7. 4. · MINERAL OIL FLUIDS HL (DIN 51524 part1) MINERAL OIL FLUIDS HLP (DIN 51524 part2) For use of environmentally acceptable fl uids (vegetable

RA 90811/01.2006© Bosch Rexroth Corporation 2015 Printed in the United States

Bosch Rexroth CorporationCorporate Headquarters14001 South Lakes DriveCharlotte, NC 28273Telephone (800) REXROTH (800) [email protected]

Find your local contact person here:www.boschrexroth-us.com/contactus