    AvailableFluidwellmodels

    Available Fluidwell Models

    ORDERING INFORMATION

  • 8/8/2019 Fluidwell Model Summary {122309}

    2/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F010-P-HC-PX-XX-ZX.ordering information: F010 -_ -H _ -P _ -X _ -Z _Flowmeter Sensor input signalA (0)4 - 20mA input.

    P Pulse input: coil, npn, pnp, namur, reed-switch.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.

    HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.PF 24V AC / DC + sensor supply.

    PL Input loop powered from sensor signal 4 - 20mA (type A).

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no real sensor supply).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other optionsZB Backlight.

    ZF Coil input 10mVpp.

    ZG Coil input 5mVpp.

    ZX No options.The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF010-0909-EN

    12

  • 8/8/2019 Fluidwell Model Summary {122309}

    3/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F011-P-HC-PX-XX-ZX.ordering information: F011 -_ -H _ -P _ -X _ -Z _Flowmeter Sensor input signalA (0)4 - 20mA input.

    P Pulse input: coil, npn, pnp, namur, reed-switch.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.

    HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.PF 24V AC / DC + sensor supply.

    PL Input loop powered from sensor signal 4 - 20mA (type A).

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no real sensor supply).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other optionsZB Backlight.

    ZF Coil input 10mVpp.

    ZG Coil input 5mVpp.

    ZX No options.The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF011-0909-EN

    12

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com

  • 8/8/2019 Fluidwell Model Summary {122309}

    4/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F012-P-HC-PX-XX-ZX.ordering information: F012 -_ -H _ -P _ -X _ -Z _Flowmeter Sensor input signalA (0)4 - 20mA input.

    P Pulse input: coil, npn, pnp, namur, reed-switch.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.

    HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.PF 24V AC / DC + sensor supply.

    PL Input loop powered from sensor signal 4 - 20mA (type A).

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no real sensor supply).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other optionsZB Backlight.

    ZF Coil input 10mVpp.

    ZG Coil input 5mVpp.

    ZX No options.The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF012-0909-EN

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com 12

  • 8/8/2019 Fluidwell Model Summary {122309}

    5/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F013-P-HC-OT-PX-XX-ZX.ordering information: F013 -_ -H _ -O _ -P _ -X _ -Z _Flowmeter Sensor input signalA (0)4 - 20mA input.

    P Pulse input: coil, npn, pnp, namur, reed-switch.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.

    HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    OutputOA One active transistor output - requires PF or PM.

    OR One mechanical relay output - requires PF or PM.

    OT One passive transistor output - standard configuration.Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.

    PF 24V AC / DC + sensor supply.

    PL Input loop powered from sensor signal 4 - 20mA (type A).

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no real sensor supply).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other optionsZB Backlight.

    ZF Coil input 10mVpp.

    ZG Coil input 5mVpp.

    ZX No options.The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF013-0909-EN

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com 12

  • 8/8/2019 Fluidwell Model Summary {122309}

    6/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F014-P-HC-OT-PX-XX-ZX.ordering information: F014 -_ -H _ -O _ -P _ -X _ -Z _Flowmeter Sensor input signalA (0)4 - 20mA input.

    P Pulse input: coil, npn, pnp, namur, reed-switch.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.

    HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    OutputOA One active transistor output - requires PF or PM.

    OR One mechanical relay output - requires PF or PM.

    OT One passive transistor output - standard configuration.Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.

    PF 24V AC / DC + sensor supply.

    PL Input loop powered from sensor signal 4 - 20mA (type A).

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no real sensor supply).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other optionsZB Backlight.

    ZF Coil input 10mVpp.

    ZG Coil input 5mVpp.

    ZX No options.The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF014-0909-EN

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com 12

  • 8/8/2019 Fluidwell Model Summary {122309}

    7/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F016-P-HC-OT-PX-XX-ZX.ordering information: F016 -_ -H _ -O _ -P _ -X _ -Z _Flowmeter Sensor input signalA (0)4 - 20mA input.

    P Pulse input: coil, npn, pnp, namur, reed-switch.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.

    HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    OutputOA One active transistor output - requires PF or PM.

    OR One mechanical relay output - requires PF or PM.

    OT One passive transistor output - standard configuration.Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.

    PF 24V AC / DC + sensor supply.

    PL Input loop powered from sensor signal 4 - 20mA (type A).

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no real sensor supply).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other optionsZB Backlight.

    ZF Coil input 10mVpp.

    ZG Coil input 5mVpp.

    ZX No options.The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF016-0909-EN

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com 12

  • 8/8/2019 Fluidwell Model Summary {122309}

    8/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F030-P-HC-OT-PX-XX-ZX.ordering information: F030 -_ -H _ -O _ -P _ -X _ -Z _Flowmeter/Pressure/Level/Temperature/Sensor input signalA (0)4 - 20mA input.

    P Pulse input: coil, npn, pnp, namur, reed-switch.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.

    HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    OutputOA One active transistor output - requires PF or PM.

    OR One mechanical relay output - requires PF or PM.

    OT One passive transistor output - standard configuration.Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.

    PF 24V AC / DC + sensor supply.

    PL Input loop powered from sensor signal type A.

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no real sensor supply).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other optionsZB Backlight.

    ZF Coil input 10mVpp.

    ZG Coil input 5mVpp.

    ZX No options.The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF030-0909-EN

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com 12

  • 8/8/2019 Fluidwell Model Summary {122309}

    9/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F040-A-HC-PX-XX-ZX.ordering information: F040 -_ -H _ -P _ -X _ -Z _Temperature sensor input signalA (0)4 - 20mA input.

    T PT100 input.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.

    HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.PF 24V AC / DC + sensor supply.

    PL Input loop powered from sensor signal 4 - 20mA (type A).

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no sensor supply for type A/U sensors).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other optionsZB Backlight.

    ZV PRTD-range -200C / +800C.

    ZX No options.

    The bold marked text contains the standard configuration.Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF040-0909-EN

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com 10

  • 8/8/2019 Fluidwell Model Summary {122309}

    10/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F043-A-HC-OT-PX-XX-ZX.ordering information: F043 -_ -H _ -O _ -P _ -X _ -Z _Temperature sensor input signalA (0)4 - 20mA input.

    T PT100 input - not available with PF / PM.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.

    HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    OutputOA One active transistor output - requires PF or PM.

    OR One mechanical relay output - requires PF or PM.

    OT One passive transistor output - standard configuration.Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.

    PF 24V AC / DC + sensor supply.

    PL Input loop powered from sensor signal 4 - 20mA (type A).

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no sensor supply for type A/U sensors).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other optionsZB Backlight.

    ZV PRTD-range -200C / +800C.

    ZX No options.The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF043-0909-EN

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com 10

  • 8/8/2019 Fluidwell Model Summary {122309}

    11/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F050-A-HC-PX-XX-ZX.ordering information: F050 -_ -H _ -P _ -X _ -Z _Pressure sensor input signalA (0)4 - 20mA input.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4

    HB Aluminum enclosure.HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.

    HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.

    PF 24V AC / DC + sensor supply.PL Input loop powered from sensor signal 4 - 20mA (type A).

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no sensor supply).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other optionsZB Backlight.

    ZX No options.The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF050-0909-EN

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com 10

  • 8/8/2019 Fluidwell Model Summary {122309}

    12/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F053-A-HC-OT-PX-XX-ZX.ordering information: F053 -_ -H _ -O _ -P _ -X _ -Z _Pressure sensor input signalA (0)4 - 20mA input.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4

    HB Aluminum enclosure.HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.

    HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    OutputOA One active transistor output - requires PF or PM.

    OR One mechanical relay output - requires PF or PM.

    OT One passive transistor output - standard configuration.

    Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.

    PF 24V AC / DC + sensor supply.

    PL Input loop powered from sensor signal 4 - 20mA (type A).

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no sensor supply).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other options

    ZB Backlight.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF053-0909-EN

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com 10

  • 8/8/2019 Fluidwell Model Summary {122309}

    13/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F070-A-HC-PX-XX-ZX.ordering information: F070 -_ -H _ -P _ -X _ -Z _Level sensor input signalA (0)4 - 20mA input.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4

    HB Aluminum enclosure.HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.

    HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.

    PF 24V AC / DC + sensor supply.PL Input loop powered from sensor signal 4 - 20mA (type A).

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no sensor supply).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other optionsZB Backlight.

    ZX No options.The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF070-0909-EN

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com 10

  • 8/8/2019 Fluidwell Model Summary {122309}

    14/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F073-A-HC-OT-PX-XX-ZX.ordering information: F073 -_ -H _ -O _ -P _ -X _ -Z _Level sensor input signalA (0)4 - 20mA input.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4

    HB Aluminum enclosure.HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.

    HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    OutputOA One active transistor output - requires PF or PM.

    OR One mechanical relay output - requires PF or PM.

    OT One passive transistor output - standard configuration.

    Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.

    PF 24V AC / DC + sensor supply.

    PL Input loop powered from sensor signal 4 - 20mA (type A).

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no sensor supply).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other options

    ZB Backlight.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF073-0909-EN

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com 10

  • 8/8/2019 Fluidwell Model Summary {122309}

    15/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F074-A-HC-OT-PX-XX-ZX.ordering information: F074 -_ -H _ -O _ -P _ -X _ -Z _Level sensor input signalA (0)4 - 20mA input.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4

    HB Aluminum enclosure.HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.

    HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    OutputOA One active transistor output - requires PF or PM.

    OR One mechanical relay output - requires PF or PM.

    OT One passive transistor output - standard configuration.

    Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.

    PF 24V AC / DC + sensor supply.

    PL Input loop powered from sensor signal 4 - 20mA (type A).

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no sensor supply).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other options

    ZB Backlight.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF074-0909-EN

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com 10

  • 8/8/2019 Fluidwell Model Summary {122309}

    16/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F077-A-HC-OT-PX-XX-ZX.ordering information: F077 -_ -H _ -O _ -P _ -X _ -Z _Level sensor input signalA (0)4 - 20mA input.

    U 0 - 10V DC input.

    Panel mount enclosures - IP65 / NEMA4

    HB Aluminum enclosure.HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.

    HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.

    HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    OutputOA One active transistor output - requires PF or PM.

    OR One mechanical relay output - requires PF or PM.

    OT One passive transistor output - standard configuration.

    Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.

    PD 16 - 30V DC + sensor supply.

    PF 24V AC / DC + sensor supply.

    PL Input loop powered from sensor signal 4 - 20mA (type A).

    PM 115 - 230V AC + sensor supply.

    PX Basic power supply 8 - 30V DC (no sensor supply).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XF EExd enclosure - 3 keys.

    XX Safe area only.

    Other options

    ZB Backlight.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF077-0909-EN

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com 10

  • 8/8/2019 Fluidwell Model Summary {122309}

    17/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F090-A-HC-PL-XX-ZX.ordering information: F090 -A -H _ -PL -X _ -Z _Sensor input signalA 4 - 20mA input.

    Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.

    HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.

    HH Cable entry: 6 x 12mm.

    HJ Cable entry: 3 x 22mm (7/8).

    HK Flat bottom, cable entry: no holes.

    Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.

    HM Cable entry: 2 x M16 + 1 x M20.

    HN Cable entry: 1 x M20.

    HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.

    HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.

    ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).

    Power supplyPL Input loop powered from sensor signal 4 - 20mA (type A).

    Hazardous areaXI Intrinsically Safe, according ATEX, IECEx, CSA c-us and FM.

    XX Safe area only.

    Other optionsZB Backlight.

    ZX No options.The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    Copyright:Fluidwellbv-2

    009-FWDSF090-0909-EN

    Fluidwell bv

    P.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com 6

  • 8/8/2019 Fluidwell Model Summary {122309}

    18/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F110-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F110 -_ -A _ -C _ -EX -H _ -I _ -O _ -P _ -TX -X _ -Z _Flowmeter input signalA (0)4 - 20mA input.P Pulse input: coil, npn, pnp, namur, reed-switch.U 0 - 10V DC input.Analog output signalAA Active 4 - 20mA output - requires OA + PD, PF or PM.AB Active 0 - 20mA output - requires OA + PD, PF or PM.

    AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires OA + PD, PF or PM.CommunicationCB Communication RS232 - Modbus ASCII / RTU.CH Communication RS485 - 2-wire - Modbus ASCII / RTU.CI Communication RS485 - 4-wire - Modbus ASCII / RTU.CT Intrinsically Safe TTL - Modbus ASCII / RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIB Terminal input to reset total.IX No external input.OutputsOA One active transistor output - requires AA, AB or AU and PD, PF or PM.OR One mechanical relay output - requires PF or PM.OT One passive transistor output - standard configuration.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.

    PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PL Input loop powered from sensor signal type A - requires AI or AF and OT.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF110-0909-EN

    12

  • 8/8/2019 Fluidwell Model Summary {122309}

    19/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F111-P-AX-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F111 -_ -AX -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _Flowmeter input signalA (0)4 - 20mA input.P Pulse input: coil, npn, pnp, namur, reed-switch.U 0 - 10V DC input.

    Analog output signalAX No analog output.CommunicationCB Communication RS232 - Modbus ASCII / RTU.CH Communication RS485 - 2-wire - Modbus ASCII / RTU.CI Communication RS485 - 4-wire - Modbus ASCII / RTU.CT Intrinsically Safe TTL - Modbus ASCII / RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.HT Cable entry: 1 x 1/2NPT.HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIX No additional input.OutputsOA two active transistor outputs - requires PD, PF or PM.OR Two mechanical relay outputs - requires PF or PM.OT Two passive transistor outputs - standard configuration.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PL Input loop powered from sensor signal type A - requires OT.

    PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply).Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF111-0909-EN

    12

  • 8/8/2019 Fluidwell Model Summary {122309}

    20/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F112-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F112 -_ -A _ -C _ _EX -H _ -I _ -O _ -P _ -TX -X _ -Z _Flowmeter input signalA (0)4 - 20mA input.P Pulse input: coil, npn, pnp, namur, reed-switch.U 0 - 10V DC input.Analog output signalAA Active 4 - 20mA output - requires OA + PD, PF or PM.AB Active 0 - 20mA output - requires OA + PD, PF or PM.

    AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires OA + PD, PF or PM.CommunicationCB Communication RS232 - Modbus RTU.CH Communication RS485 - 2-wire - Modbus RTU.CI Communication RS485 - 4-wire - Modbus RTU.CT Intrinsically Safe TTL - Modbus RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIB Terminal input to reset total.IX No external input.OutputsOA One active transistor output - requires AA, AB or AU and PD, PF or PM.OR One mechanical relay output - requires PF or PM.OT One passive transistor output - standard configuration.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.

    PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PL Input loop powered from sensor signal type A - requires AI or AF and OT.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF112-0909-EN

    12

  • 8/8/2019 Fluidwell Model Summary {122309}

    21/40

    Ordering informationStandard configuration: F113-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F113 -_ -A _ -C _ -EX -H _ -I _ -O _ -P _ -TX -X _ -Z _Flowmeter input signalA (0)4 - 20mA input.P Pulse input: coil, npn, pnp, namur, reed-switch.U 0 - 10V DC input.Analog output signalAA Active 4 - 20mA output - requires OA + PD, PF or PM.AB Active 0 - 20mA output - requires OA + PD, PF or PM.

    AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires OA + PD, PF or PM.CommunicationCB Communication RS232 - Modbus ASCII / RTU.CH Communication RS485 - 2-wire - Modbus ASCII / RTU.CI Communication RS485 - 4-wire - Modbus ASCII / RTU.CT Intrinsically Safe TTL - Modbus ASCII / RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x1

    /2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).InputsIB Terminal input to reset total.IX No external input.OutputsOA Three active transistor outputs - requires AA, AB or AU and PD, PF or PM.OR Two mechanical relay outputs + one OA or OT - requires PF or PM.OS Four mechanical relay outputs - requires AP + PD.OT Three passive transistor outputs - standard configuration.Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PL Input loop powered from sensor signal type A - requires AF or AI and OT.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.

    ZX No options.The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF113-0909-EN

    12

    Specifications are subject to change without notice.

  • 8/8/2019 Fluidwell Model Summary {122309}

    22/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F114-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F114 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _Flowmeter input signalA (0)4 - 20mA input.P Pulse input: coil, npn, pnp, namur, reed-switch.U 0 - 10V DC input.Analog output signalAA Active 4 - 20mA output - requires OA + PD, PF or PM.

    AB Active 0 - 20mA output - requires OA + PD, PF or PM.AF I.S. floating 4 - 20mA output - requires XI + PC, PD or PL.AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires OA + PD, PF or PM.CommunicationCB Communication RS232 - Modbus RTU.CH Communication RS485 - 2wire - Modbus RTU.CI Communication RS485 - 4 wire - Modbus RTU.CT Intrinsically Safe TTL - Modbus RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIX No additional input.OutputsOA Three active transistor outputs - requires AA, AB or AU and PD, PF or PM.OR Two mechanical relay outputs + one OT or OA - requires PF or PM.OT Three passive transistor outputs - standard configuration.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.

    PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PL Input loop powered from sensor signal type A - requires AI or AF and OT.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF114-0909-EN

    12

  • 8/8/2019 Fluidwell Model Summary {122309}

    23/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F115-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F115 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _Flowmeter input signalP Pulse input: coil, npn, pnp, namur, reed-switch.Analog output signalAA Active 4 - 20mA output - requires OA + PD, PF or PM.

    AB Active 0 - 20mA output - requires OA + PD, PF or PM.AF I.S. floating 4 - 20mA output - requires XI + PC or PD.AI Isolated 4 - 20mA output - requires PB, PD, PF or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires OA + PD, PF or PM.CommunicationCB Communication RS232 - Modbus RTU.CH Communication RS485 - 2-wire - Modbus RTU.CI Communication RS485 - 4-wire - Modbus RTU.CT Intrinsically Safe TTL - Modbus RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 flow rate 1 x M20.HM Cable entry: 2 x M16 flow rate 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.

    HT Cable entry: 1 x1

    /2NPT.HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIX No additional input.OutputsOA Two active transistor outputs - requires AA, AB or AU and PD, PF or PM.OR Two mechanical relay outputs - requires PF or PM.OT Two passive transistor outputs - standard configuration.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.

    PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF115-0909-EN

    12

  • 8/8/2019 Fluidwell Model Summary {122309}

    24/40

    Ordering informationStandard configuration: F116-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F116 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _Flowmeter input signalA (0)4 - 20mA input.P Pulse input: coil, npn, pnp, namur, reed-switch.U 0 - 10V DC input.Analog output signalAA Active 4 - 20mA output - requires OA + PD, PF or PM.

    AB Active 0 - 20mA output - requires OA + PD, PF or PM.AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires OA + PD, PF or PM.CommunicationCB Communication RS232 - Modbus RTU.CH Communication RS485 - 2wire - Modbus RTU.CI Communication RS485 - 4 wire - Modbus RTU.CT Intrinsically Safe TTL - Modbus RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIX No additional input.OutputsOA Two active transistor outputs - requires AA, AB or AU and PD, PF or PM.OR Two mechanical relay outputs - requires PF or PM.OT Two passive transistor outputs - standard configuration.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.

    PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PL Input loop powered from sensor signal type A - requires AI or AF and OT.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF116-0909-EN

    12

    Specifications are subject to change without notice.

  • 8/8/2019 Fluidwell Model Summary {122309}

    25/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F117-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F117 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _Flowmeter input signalP Pulse input: coil, npn, pnp, namur, reed-switch.Analog output signalAA Active 4 - 20mA output - requires OA + PD, PF or PM.

    AB Active 0 - 20mA output - requires OA + PD, PF or PM.AF I.S. floating 4 - 20mA output - requires XI + PC or PD.AI Isolated 4 - 20mA output - requires PB, PD, PF or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires OA + PD, PF or PM.CommunicationCB Communication RS232 - Modbus RTU.CH Communication RS485 - 2-wire - Modbus RTU.CI Communication RS485 - 4-wire - Modbus RTU.CT Intrinsically Safe TTL - Modbus RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.

    HT Cable entry: 1 x1

    /2NPT.HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIX No additional input.OutputsOA Two active transistor outputs - requires AA, AB or AU and PD, PF or PM.OR Two mechanical relay outputs - requires PF or PM.OT Two passive transistor outputs - standard configuration.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.

    PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF117-0909-EN

    12

  • 8/8/2019 Fluidwell Model Summary {122309}

    26/40

    Ordering informationStandard configuration: F118-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F118 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _Flowmeter input signalA (0)4 - 20mA input.P Pulse input: coil, npn, pnp, namur, reed-switch.U 0 - 10V DC input.Analog output signalAA Active 4 - 20mA output - requires OA + PD, PF or PM.

    AB Active 0 - 20mA output - requires OA + PD, PF or PM.AF I.S. floating 4 - 20mA output - requires XI + PC, PD or PL.AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires OA + PD, PF or PM.CommunicationCB Communication RS232 - Modbus RTU.CH Communication RS485 - 2wire - Modbus RTU.CI Communication RS485 - 4 wire - Modbus RTU.CT Intrinsically Safe TTL - Modbus RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIX No additional input.OutputsOA Three active transistor outputs - requires AA, AB or AU and PD, PF or PM.OR Two mechanical relay outputs + one OT or OA - requires PF or PM.OT Three passive transistor outputs - standard configuration.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.

    PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PL Input loop powered from sensor signal type A - requires AI or AF and OT.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF118-0909-EN

    12

    Specifications are subject to change without notice.

  • 8/8/2019 Fluidwell Model Summary {122309}

    27/40

    Specifications are subject to change without notice.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF120-0909-EN

    12

    Ordering informationStandard configuration: F120-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F120 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _Flowmeter input signalP Pulse input: coil, npn, pnp, namur, reed-switch.Analog output signalAA Active 4 - 20mA output - requires OA + PD, PF or PM.

    AB Active 0 - 20mA output - requires OA + PD, PF or PM.AF I.S. floating 4 - 20mA output - requires XI + PC or PD.AI Isolated 4 - 20mA output - requires PB, PD, PF or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires OA + PD, PF or PM.CommunicationCB Communication RS232 - Modbus RTU.CH Communication RS485 - 2-wire - Modbus RTU.CI Communication RS485 - 4-wire - Modbus RTU.CT Intrinsically Safe TTL - Modbus RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.

    HT Cable entry: 1 x1

    /2NPT.HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIB Terminal input to reset total / keylock.IX No additional input.OutputsOA Two active transistor outputs - requires AA, AB or AU and PD, PF or PM.OR Two mechanical relay outputs - requires PF or PM.OT Two passive transistor outputs - standard configuration.Power supplyPB Lithium battery powered.

    PC Lithium battery powered - Intrinsically Safe.PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZX No options.

    The bold marked text contains the standard configuration.Available Intrinsically Safe.

  • 8/8/2019 Fluidwell Model Summary {122309}

    28/40

    Specifications are subject to change without notice.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF124-0909-EN

    12

    Ordering informationStandard configuration: F124-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F124 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _Flowmeter input signalP Pulse input: coil, npn, pnp, namur, reed-switch.Analog output signalAA Active 4 - 20mA output - requires OA + PD, PF or PM.

    AB Active 0 - 20mA output - requires OA + PD, PF or PM.AF I.S. floating 4 - 20mA output - requires XI + PC or PD.AI Isolated 4 - 20mA output - requires PB, PD, PF or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires OA + PD, PF or PM.CommunicationCB Communication RS232 - Modbus RTU.CH Communication RS485 - 2-wire - Modbus RTU.CI Communication RS485 - 4-wire - Modbus RTU.CT Intrinsically Safe TTL - Modbus RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.

    HT Cable entry: 1 x1

    /2NPT.HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIX No additional input.OutputsOA Two active transistor outputs - requires AA, AB or AU and PD, PF or PM.OR Two mechanical relay outputs - requires PF or PM.OT Two passive transistor outputs - standard configuration.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.

    PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

  • 8/8/2019 Fluidwell Model Summary {122309}

    29/40

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF126EG-0909-EN

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F126-P-AP-CX-EG-HC-IA-OX PX-TA-XX-ZX.Ordering information: F126 -_ -A _ -C _ -EG -H _ -I _ -OX -P _ -T _ -X _ -Z _Flowmeter input signalA (0)4 - 20mA input.P Pulse input: coil, npn, pnp, namur, reed-switch.U 0 - 10V DC input.Analog output signalAA Active 4 - 20mA output - requires PD or PM.AB Active 0 - 20mA output - requires PD or PM.

    AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.AI Isolated 4 - 20mA output - requires PB, PD, PL or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires PD or PM.CommunicationCB Communication RS232 - Modbus RTU.CH Communication RS485 - 2wire - Modbus RTU.CI Communication RS485 - 4 wire - Modbus RTU.CT Intrinsically Safe TTL - Modbus RTU.CX No communication.Flow equationsEG Corrected gas volume.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x1

    /2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Pressure inputIA (0)4 - 20mA input.IU 0 - 10V DC input.OutputsOX No output.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PL Input loop powered from sensor signal type A - requires AI or AF and OT.

    PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature inputTA (0)4 - 20mA input.TP PT100 input.TU 0 - 10V DC input.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZV PRTD-range -200C / +800C.ZX No options.

    The bold marked text contains the standard configuration.Available Intrinsically Safe.

    12

  • 8/8/2019 Fluidwell Model Summary {122309}

    30/40

    Specifications are subject to change without notice.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF126EL-0909-EN

    12

    Ordering informationStandard configuration: F126-P-AP-CX-EL-HC-IX-OX PX-TA-XX-ZX.Ordering information: F126 -_ -A _ -C _ -EL -H _ -IX -OX -P _ -T _ -X _ -Z _Flowmeter input signalA (0)4 - 20mA input.P Pulse input: coil, npn, pnp, namur, reed-switch.U 0 - 10V DC input.Analog output signalAA Active 4 - 20mA output - requires PD or PM.

    AB Active 0 - 20mA output - requires PD or PM.AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.AI Isolated 4 - 20mA output - requires PB, PD, PL or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires PD or PM.CommunicationCB Communication RS232 - Modbus RTU.CH Communication RS485 - 2wire - Modbus RTU.CI Communication RS485 - 4 wire - Modbus RTU.CT Intrinsically Safe TTL - Modbus RTU.CX No communication.Flow equationsEL Corrected liquid volume.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIX No additional input.OutputsOX No output.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PL Input loop powered from sensor signal type A - requires AI or AF and OT.

    PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature inputTA (0)4 - 20mA input.TP PT100 input.TU 0 - 10V DC input.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZV PRTD-range -200C / +800C.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

  • 8/8/2019 Fluidwell Model Summary {122309}

    31/40

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF127-0909-EN

    Ordering informationStandard configuration: F127-P-AP-CX-EL-HC-IX-OX-PX-TA-XX-ZX.Ordering information: F127 -P -A _ -C _ -EL -H _ -IX -OX -P _ -T _ -X _ -Z _Flowmeter input signalP Pulse: coil, npn, pnp, namur, reed-switch input.Analog output signalAA Active 4 - 20mA output - requires PD, PF or PM.

    AB Active 0 - 20mA output - requires PD, PF or PM.AF I.S. floating 4 - 20mA output - requires XI + PC or PD.AI Isolated 4 - 20mA output - requires PB, PD, PF or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires PD, PF or PM.CommunicationCB Communication RS232 - Modbus RTU.CH Communication RS485 - 2-wire - Modbus RTU.CI Communication RS485 - 4-wire - Modbus RTU.CT Intrinsically Safe TTL - Modbus RTU.CX No communication.Flow equationEL Corrected liquid volume.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.

    HT Cable entry: 1 x1

    /2NPT.HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIX No additional input.OutputsOX No output.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.PD 8 - 24V AC/DC + sensor supply - in combination with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply - only available with TP.

    PM 115 - 230V AC + sensor supply - only available with TP.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature input signalTA (0)4 - 20mA input.TP PT100 input.TU 0 - 10V DC input.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.OptionsZB Backlight.ZF Coil input 10mVpp.ZV PRTD-range -200C / +800C.ZX No options.

    The bold marked text contains the standard configuration.Available Intrinsically Safe.

    12

    Specifications are subject to change without notice.

  • 8/8/2019 Fluidwell Model Summary {122309}

    32/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F130-P-AX-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F130 -_ -AX -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _Flowmeter input signalA (0)4 - 20mA input.P Pulse input: coil, npn, pnp, namur, reed-switch.U 0 - 10V DC input.

    Analog output signalAX No analog output.CommunicationCB Communication RS232 - Modbus ASCII / RTU.CH Communication RS485 - 2-wire - Modbus ASCII / RTU.CI Communication RS485 - 4-wire - Modbus ASCII / RTU.CT Intrinsically Safe TTL - Modbus ASCII / RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.

    HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.HT Cable entry: 1 x 1/2NPT.HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.

    HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIX No additional input.OutputsOA Two active transistor outputs - requires PD, PF or PM.OR Two mechanical relay outputs - requires PF or PM.OT Two passive transistor outputs - standard configuration.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PL Input loop powered from sensor signal type A.

    PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply).Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF130-0909-EN

    12

  • 8/8/2019 Fluidwell Model Summary {122309}

    33/40

    Ordering informationStandard configuration: F131-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F131 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _Flowmeter input signalA (0)4 - 20mA input.P Pulse input: coil, npn, pnp, namur, reed-switch.U 0 - 10V DC input.Analog output signalAA Active 4 - 20mA output - requires OA + PD, PF or PM.

    AB Active 0 - 20mA output - requires OA + PD, PF or PM.AF I.S. floating 4 - 20mA output - requires XI - PC, PD or PL.AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires OA + PD, PF or PM.CommunicationCB Communication RS232 - Modbus RTU.CH Communication RS485 - 2wire - Modbus RTU.CI Communication RS485 - 4 wire - Modbus RTU.CT Intrinsically Safe TTL - Modbus RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIX No additional input.OutputsOA Two active transistor outputs - requires AA, AB or AU and PD, PF or PM.OR Two mechanical relay outputs - requires PF or PM.OT Two passive transistor outputs - standard configuration.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.

    PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PL Input loop powered from sensor signal type A - requires AF or AI and OT.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF131-0909-EN

    12

    Specifications are subject to change without notice.

  • 8/8/2019 Fluidwell Model Summary {122309}

    34/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F133-P-AX-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F133 -_ -AX -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _Flowmeter input signalP Pulse input: coil, npn, pnp, namur, reed-switch.Analog output signalAX No analog output.

    CommunicationCB Communication RS232 - Modbus RTU.CH Communication RS485 - 2wire - Modbus RTU.CI Communication RS485 - 4 wire - Modbus RTU.CT Intrinsically Safe TTL - Modbus RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).

    HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.HT Cable entry: 1 x 1/2NPT.HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosures

    HS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIX No additional input.OutputsOA Two active transistor outputs - requires PD, PF or PM.OR Two mechanical relay outputs - requires PF or PM.OT Two passive transistor outputs - standard configuration.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.PD 8 - 24V AC / DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC / DC + sensor supply.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply).Temperature input signal

    TX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF133-0909-EN

    12

  • 8/8/2019 Fluidwell Model Summary {122309}

    35/40

    Specifications are subject to change without notice.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.fluidwell.com C

    opyright:Fluidwellbv-2

    009-FWDSF136-0909-EN

    Ordering informationStandard configuration: F136-P-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F136 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _Flowmeter input signalA (0)4 - 20mA input.P Pulse input: coil, npn, pnp, namur, reed-switch.U 0 - 10V DC input.Analog output signalAA Active 4 - 20mA output - requires OA + PD, PF or PM.

    AB Active 0 - 20mA output - requires OA + PD, PF or PM.AF I.S. floating 4 - 20mA output - requires XI + PC, PL or PD.AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires OA + PD, PF or PM.CommunicationCB Communication RS232 - Modbus RTU.CH Communication RS485 - 2wire - Modbus RTU.CI Communication RS485 - 4 wire - Modbus RTU.CT Intrinsically Safe TTL - Modbus RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.

    HC GRP enclosure.GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.

    HT Cable entry: 1 x 1/2NPT.HU Cable entry: 3 x 1/2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIX No additional input.OutputsOA Two active transistor outputs - requires AA, AB or AU and PD, PF or PM.OR Two mechanical relay outputs - requires PF or PM.OT Two passive transistor outputs - standard configuration.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.

    PD 8 - 24V AC/DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC/DC + sensor supply.PL Input loop powered from sensor signal type A - requires AI or AF and OT.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZF Coil input 10mVpp.ZX No options.

    The bold marked text contains the standard configuration.

    Available Intrinsically Safe.

    12

  • 8/8/2019 Fluidwell Model Summary {122309}

    36/40

    Specifications are subject to change without notice.

    Ordering informationStandard configuration: F143-A-AP-CX-EX-HC-IX-OT-PX-TX-XX-ZX.Ordering information: F143 -_ -A _ -C _ -EX -H _ -IX -O _ -P _ -TX -X _ -Z _Temperature signalA (0)4 - 20mA input.T PT100 input.U 0 - 10V DC input.Analog output signalAA Active 4 - 20mA output - requires OA + PD, PF or PM.AB Active 0 - 20mA output - requires OA + PD, PF or PM.

    AF I.S. floating 4 - 20mA output - requires XI + PC, PD or PL.AI Isolated 4 - 20mA output - requires PB, PD, PF, PL or PM.AP Passive 4 - 20mA output, loop powered unit.AU Active 0 - 10V DC output - requires OA + PD, PF or PM.CommunicationCB Communication RS232 - Modbus ASCII / RTU.CH Communication RS485 - 2-wire - Modbus ASCII / RTU.CI Communication RS485 - 4-wire - Modbus ASCII / RTU.CT Intrinsically Safe TTL - Modbus ASCII / RTU.CX No communication.Flow equationsEX No flow equations.Panel mount enclosures - IP65 / NEMA4HB Aluminum enclosure.HC GRP enclosure.

    GRP field / wall mount enclosures - IP67 / NEMA4XHD Cable entry: no holes.HE Cable entry: 2 x 16mm & 1 x 20mm.HF Cable entry: 1 x 22mm (7/8).HG Cable entry: 2 x 20mm.HH Cable entry: 6 x 12mm.HJ Cable entry: 3 x 22mm (7/8).HK Flat bottom, cable entry: no holes.Aluminum field / wall mount enclosures - IP67 / NEMA4XHA Cable entry: 2 x PG9 + 1 x M20.HM Cable entry: 2 x M16 + 1 x M20.HN Cable entry: 1 x M20.HO Cable entry: 2 x M20.HP Cable entry: 6 x M12.HT Cable entry: 1 x 1/2NPT.

    HU Cable entry: 3 x1

    /2NPT.HV Cable entry: 4 x M20.HZ Cable entry: no holes.ABS field / wall mount enclosuresHS Silicone free ABS field enclosure IP65 Cable entry: no holes (old HD enclosure).Additional inputsIX No additional input.OutputsOA Three active transistor outputs - requires AA, AB or AU and PD, PF or PM.OR Two mechanical relay outputs + one OT or OA - requires PF or PM.OS Four mechanical relay outputs - requires AP and PD.OT Three passive transistor outputs - standard configuration.Power supplyPB Lithium battery powered.PC Lithium battery powered - Intrinsically Safe.

    PD 8 - 24V AC / DC + sensor supply - with XI: 16 - 30V DC.PF 24V AC / DC + sensor supply.PL Input loop powered from sensor signal type A - requires AI or AF and OT.PM 115 - 230V AC + sensor supply.PX Basic power supply 8 - 30V DC (no real sensor supply). Unit requires external loop AP.Temperature input signalTX No temperature input signal.Hazardous areaXI Intrinsically Safe, according ATEX.XF EExd enclosure - 3 keys.XX Safe area only.Other optionsZB Backlight.ZV PRTD-range -200C / +800C.ZX No options.

    The bold marked text contains the standard configuration.Available Intrinsically Safe.

    FLUIDWELL bvP.O. Box 65460 AA - Veghel - The NetherlandsTel.: +31 (0)413 343786Fax.: +31 (0)413 [email protected]: www.